• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 2
  • 1
  • Tagged with
  • 3
  • 3
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Cuantificación de las expectativas de precios a partir de la encuesta industrial de la UE

Clavería González, Óscar 29 April 2003 (has links)
El presente trabajo se enmarca dentro de una corriente de la literatura centrada en la utilización de los datos cualitativos de las encuestas de opinión para la predicción a corto plazo. El objetivo es extraer el máximo provecho de la información disponible contenida en las encuestas de opinión con fines predictivos. Para ello se desarrolla un nuevo método de cuantificación que permite obtener predicciones de la tasa de crecimiento esperada a partir de la información cualitativa contenida en las encuestas de opinión.En este tipo de encuestas se pregunta periódicamente a empresarios y consumidores sobre la evolución percibida y esperada de las principales variables económicas que afectan a su actividad. Esta característica hace que los resultados obtenidos a partir de estas encuestas tengan un gran valor anticipatorio y sean menos susceptibles ante errores de muestreo y de medición que los provenientes de encuestas que requieren predicciones puntuales. Por este motivo, las encuestas de opinión son la principal fuente de obtención de expectativas directamente observadas.Esta última ventaja entraña a su vez una de las limitaciones fundamentales de este tipo de encuestas. El hecho de que la información sea cualitativa hace necesaria la implementación de algún tipo de transformación con el objetivo de hacerla más fácilmente interpretable y de poderla analizar con el instrumental estadístico convencional.La necesidad de transformar las respuestas policotómicas sobre la dirección del cambio en medidas cuantitativas está en el origen de la literatura relacionada con el diseño de métodos de cuantificación. No obstante, la escasa capacidad predictiva mostrada por los métodos de cuantificación propuestos hasta el momento los hace difícilmente aplicables en el ámbito de la coyuntura.Además, la aplicación de estos métodos requiere de ciertos supuestos difícilmente contrastables: igual distribución de las respuestas sobre la percepción pasada y la expectativa futura de una variable, simetría y constancia en el tiempo de la tasa de crecimiento por debajo de la cual los encuestados no perciben cambio alguno en la variable, etc.La metodología presentada en este trabajo permite relajar y contrastar algunos de estos supuestos. A partir del modelo probabilístico con intervalo de indiferencia asimétrico y dinámico se desarrolla un método general del cual se derivan otros dos métodos que pueden entenderse como casos particulares del primero. Mediante una representación "state-space" más flexible y la utilización del filtro de Kalman, los tres métodos propuestos permiten estimar parámetros de indiferencia asimétricos y cambiantes en el tiempo sin necesidad de utilizar las percepciones sobre la evolución pasada de la variable.Se realiza también una aplicación para las expectativas sobre los precios de venta de las manufacturas en los países miembros de la Unión Europea y en el conjunto de la Zona Euro. Este análisis empírico permite comparar los resultados obtenidos mediante la nueva metodología con los que se desprenden de los principales métodos existentes. A partir de una evaluación comparativa de la capacidad predictiva de las diferentes series de expectativas de crecimiento de los precios industriales estimadas se escoge el método más adecuado.Dado el objetivo predictivo del presente trabajo, la fuente de error que se pretende minimizar es la introducida al cuantificar los datos sobre la dirección de cambio. Por este motivo, el análisis empírico se complementa con un experimento de simulación que permite diferenciar entre las diferentes fuentes de error, y así, seleccionar el método con un menor error de medida o de conversión.A pesar de que el análisis se centra en los precios industriales, la metodología es extensible a cualquier otra variable contenida en las encuestas de opinión para la que se disponga de una serie cuantitativa de referencia.
2

Absolute quantification in brain SPECT imaging

Cot Sanz, Albert 17 December 2003 (has links)
Certes malalties neurològiques estan associades amb problemes en els sistemes de neurotransmissió. Una aproximació a l'estudi d'aquests sistemes és la tomografia d'emissió SPECT (Single Photon Emission Computed Tomography) com a tècnicano-invasiva que proporciona imatges funcionals representatives de l'activitat neuronal. Aquesta tècnica permet la visualització i l'anàlisi de diferents òrgans i teixits dins l'àmbit de la Medicina Nuclear.Malgrat que la inspecció visual de la imatge a vegades és suficient per establir el diagnòstic, la quantificació dels paràmetres de la imatge reconstruida poden millorar la fiabilitat i exactitud del diagnòstic precoç de la malaltia. En particular, la quantificació d'estudis de neurotransmissors de dopamina pot ajudar a detectar els estadis inicials de malalties com el Parkinson. Així mateix, la quantificació permet un seguiment més acurat de l'evolució de la malaltia i una evaluació dels efectes de la terapèutica aplicada.La quantificació es veu afectada pels efectes degradants de la imatge com són el soroll estadístic, la resposta del sistema col.limador/detector i l'efecte de dispersió i/o atenuació dels fotons en la seva interacció amb la matèria. Alguns d'aquests efectes poden ser corregits mitjançant l'ús d'algoritmes de reconstrucció iteratius.L'objectiu d'aquesta tesi és aconseguir una quantificació tant absoluta com relativa dels valors numèrics de la imatge reconstruida de manera que reprodueixin la distribució d'activitat real del pacient en el moment de l'adquisició de l'estudi de SPECT. Per aconseguir-ho s'han desenvolupat diferents codis i algoritmes per millorar els mètodes de reconstrucció existents i validar-ne els seus resultats.La validació i millora dels algoritmes s'ha basat en l'ús de tècniques de simulació Monte Carlo. S'han analitzat els diferents codis Monte Carlo disponibles en l'àmbit de la Medicina Nuclear i s'ha escollit SimSET. La interpretació dels resultats obtinguts i la comparació amb els resultats experimentals ens van dur a incorporar modificacions en el codi original. D'aquesta manera vam obtenir i validar SimSET com a generador d'estudis de SPECT a partir de pacients i objectes virtuals.La millora dels algoritmes es va basar en la incorporació de models analítics de la resposta del sistema col.limador/detector. La modelització del sistema es va implementar per diferents configuracions i energies de la font amb la utilització del codi Monte Carlo PENELOPE. Així mateix es va dissenyar un nou algoritme iteratiu que incorporés l'efecte 3D del sistema i es va tenir en compte la valoració de la imatge en tot el seu volum.Finalment, es va proposar una correcció de l'scattering utilitzant el simulador SimSET modificat per tal d'accelerar el procés de reconstrucció. Els valors reconstruits de la imatge ens han permès recuperar més d'un 95\% dels valors originals, permetent per tant la quantificació absoluta de les imatges de SPECT. / Many forms of brain diseases are associated with problems in the neurotransmission systems. One approach to the assessment of such systems is the use of Single Photon Emission Computed Tomography (SPECT) brain imaging. Neurotransmission SPECT has become an important tool in neuroimaging and is today regarded as a useful method in both clinical and basic research. SPECT is able to non-invasively visualize and analyze different organs and tissues functions or properties in Nuclear Medicine.Although visual inspection is often sufficient to assess neurotransmission imaging, quantification might improve the diagnostic accuracy of SPECT studies of the dopaminergic system. In particular, quantification of neurotransmission SPECT studies in Parkinson Disease could help us to diagnose this illness in the early pre-clinical stages. One of the main research topics in SPECT is to achieve early diagnosis, indeed preclinical diagnosis in neurodegenerative illnesses. In this field detailed analysis of shapes and values of the region of interest (ROIs) of the image is important, thus quantification is needed. Moreover, quantification allows a follow-up of the progression of disease and to assess the effects of potential neuroprotective treatment strategies. Therefore, the aim of this thesis is to achieve quantification of both the absolute activity values and the relative values of the reconstructed SPECT images.Quantification is affected by the degradation of the image introduced by statistical noise, attenuation, collimator/detector response and scattering effects. Some of these degradations may be corrected by using iterative reconstruction algorithms, which thus enable a more reliable quantification. The importance of correcting degradations in reconstruction algorithms to improve quantification accuracy of brain SPECT studies has been proved.Monte Carlo simulations are the --gold standard' for testing reconstruction algorithms in Nuclear Medicine. We analyzed the available Monte Carlo codes and we chose SimSET as a virtual phantom simulator. A new stopping criteria in SimSET was established in order to reduce the simulation time. The modified SimSET version was validated as a virtual phantom simulator which reproduces realistic projection data sets in SPECT studies.Iterative algorithms permit modelling of the projection process, allowing for correction of spatially variant collimator response and the photon crosstalk effect between transaxial slices. Thus, our work was focused on the modelling of the collimator/detector response for the parallel and fan beam configurations using the Monte Carlo code PENELOPE. Moreover, a full 3D reconstruction with OS-EM algorithms was developed.Finally, scattering has recognized to be one of the most significant degradation effects in SPECT quantification. Nowadays this subject is an intensive field of research in SPECT techniques. Monte Carlo techniques appear to be the most reliable way to include this correction. The use of the modified SimSET simulator accelerates the forward projection process although the computational burden is already a challenge for this technique.Full 3D reconstruction simultaneously applied with Monte Carlo-based scattering correction and the 3D evaluation procedure is a major upgrade technique in order to obtain valuable, absolute quantitative estimates of the reconstructed images. Once all the degrading effects were corrected, the obtained values were 95\% of the theoretical values. Thus, the absolute quantification was achieved.
3

Optimización de ensayos celulares para la detección de toxinas marinas responsables de intoxicaciones alimentarias. Aplicación en extractos lipofílicos de muestras naturales de "Mytilus galloprovincialis"

Cañete Ortiz, Elisabet 15 June 2012 (has links)
Esta tesis doctoral tiene por objeto el estudio de la aplicabilidad de los cultivos celulares de mamífero como uso de métodos toxicológicos alternativo al uso de métodos establecidos con animales de experimentación en la detección y cuantificación de toxinas marinas responsables de intoxicaciones alimentarias. Incluye cuatro artículos ya publicados y un manuscrito sometido a publicación en revista indexada. Hasta el momento, el uso de los ensayos celulares (Cell Based Assays, CBAs) como métodos toxicológicos de detección y cuantificación de toxinas marinas en alimentos de origen alimentario se había enfocado por grupos de toxinas con mecanismo de acción similar. En esta tesis, lo que se ha propuesto es simplificar la estrategia de uso de los CBAs mediante un único modelo celular capaz de detectar y cuantificar el efecto tóxico del mayor número de grupos de toxinas partiendo de las siguientes prioridades:  Sensibilidad y repetitividad de respuesta del/os ensayo/s a la detección de la toxicidad teniendo en cuenta los mecanismos de toxicidad implicados.  Reducción del tiempo, complejidad y costes del método.  Interpretación de los resultados.  Priorización de la puesta a punto del método para aquellas toxinas que tienen un mayor impacto en las zonas de muestreo de este estudio. Los pasos seguidos en la optimización se han dividido en dos grandes bloques: Un primer bloque en el que se trabajó con toxinas purificadas estándar a fin de establecer las condiciones de los ensayos para la detección y cuantificación de las toxinas, así como contribuir a la caracterización toxicológica de las diferentes toxinas. Un segundo bloque, en el que se trabajó con muestras naturales con toxinas a fin de establecer las condiciones en situaciones reales. Para evaluar la respuesta del CBA frente a toxinas purificadas se escogieron toxinas representativas de los grupos más comunes. Para el primer grupo de ensayos (Cañete and Diogène, 2008) se utilizó: STX, PbTx-3, PlTX, PTX-2, OA, DTX-1, DA. Para el segundo grupo de ensayos (Cañete and Diogène, 2010) se amplíaron los estudios a toxinas actuando sobre canales de sodio dependientes de voltaje (STX, PbTx-3 y P-CTX) y a toxinas lipofílicas (OA, DTX-1, PTX-2, YTX y AZA-1). Para evaluar la respuesta del CBA frente a muestras naturales con toxinas (Caillaud et al., 2009; Cañete et al., 2010; Cañete et al.) se utilizaron muestras de bivalvos procedentes del Delta del Ebro. Por su elevada importancia en el área geográfica en la que nos encontramos, este trabajo se centró en la optimización del CBA para toxinas del tipo lipofílico. En este trabajo se proponen como conclusiones unas directrices a seguir para el uso de CBAs en este contexto. PUBLICACIONES Caillaud, A., Cañete, E., De la Iglesia, P., Giménez, G., Diogène, J., 2009. Cell-based assay coupled with chromatographic fractioning: A strategy for marine toxins detection in natural samples. Toxicology in Vitro 23 (8), 1591-1596. Cañete, E., Campàs, M., De la Iglesia, P., Diogène, J., 2010. NG108-15 cell-based and protein phosphatase inhibition assays as alternative semiquantitative tools for the screening of lipophilic toxins in mussels. Okadaic acid detection. Toxicology in Vitro 24 (2), 611-619. Cañete, E., De la Iglesia, P., Diogène, J., Evaluation of a toxicological alternative tool for lipophilic toxicity screening in mussels. NG108-15 cell-based assay coupled to chromatographic fractioning; a case study for YTX contamination. Toxicology in Vitro. Submitted. Cañete, E., Diogène, J., 2008. Comparative study of the use of neuroblastoma cells (Neuro-2a) and neuroblastoma x glioma hybrid cells (NG108-15) for the toxic effect quantification of marine toxins. Toxicon 52 (4), 541-550. Cañete, E., Diogène, J., 2010. Improvements in the use of neuroblastoma x glioma hybrid cells (NG108-15) for the toxic effect quantification of marine toxins. Toxicon 55 (2-3), 381-389. / ABSTRACT This thesis aims to study the applicability of mammalian cell cultures as a toxicological alternative to the mouse bioassay in the detection and quantification of marine toxins which can produce food-borne intoxications. The study includes four published articles, and a manuscript submitted, in indexed journals. On previous studies, the use of Cell Based Assays (CBAs) as a toxicological method for marine toxins screening on seafood products were focused on toxins with similar mechanism of action. This thesis was oriented to simplify the strategy and propose a CBA, with a single cell model, able to detect and quantify the toxic effect of a higher number of groups of toxins. The following priorities were considered for the assay:  Sensitivity and repeatability of the assay for the detection of the toxic effects taking into considerations the mechanisms of action involved.  Reduce time, complexity and costs of the method.  Interpretation of results.  Prioritize improvements of assay conditions for those toxins which have a greater impact on the sampling areas of this study. The experiments performed in the optimization can be divided into two main groups: The first group of experiments were performed with standard purified toxins to establish assays conditions for the detection and quantification of toxicity and to contribute to the toxicological characterization of the different groups of toxins. For this propose some toxins were chosen as a representation of the principal groups. For the first set of tests, the following toxins were used: STX, PbTx-3, PlTX, PTX-2, OA, DTX-1 and DA. For the second group of tests, studies were extended to toxins acting on voltage gated sodium channels (STX, PbTx-3 and P-CTX) and lipophilic toxins (OA, DTX-1, PTX-2, YTX and AZA-1). A second group of experiments were performed with bivalve natural samples containing toxins to establish the conditions in real situations. For this propose samples were obtained from the Ebre Delta. This part of the study was focused to optimize the assay for lipophilic toxins which are of particular relevance in this geographical area. In this thesis we finally propose some guidelines for the use of CBAs as a toxicological tool for marine toxins screening and the points which needs improvements in order to obtain a method alternative to the mouse bioassay.

Page generated in 0.6197 seconds