• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 68
  • 29
  • 13
  • 3
  • 2
  • 1
  • 1
  • 1
  • Tagged with
  • 119
  • 42
  • 41
  • 41
  • 26
  • 21
  • 21
  • 20
  • 17
  • 14
  • 13
  • 12
  • 12
  • 11
  • 11
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
41

A Schenkerian Analysis and Interpretation of Joseph Jongen's Eclectic "Vingt-quatre petits préludes dans tous les tons pour piano," Op. 116 (1940-1941)

Liu, Yi 05 1900 (has links)
Belgian composer Joseph Jongen (1873-1953) was an eclectic composer who successfully maintained his own unique musical vocabulary—particularly in his piano compositions. Jongen composed very little between 1940-1941—the period in which he and his family fled to the countryside of Mazères, France, living as refugees for several months before returning to Sart-lez-Spa, Belgium, due to the outbreak of WWII. Reflective of this time in his life, Vingt-quatre petits préludes dans tous les tons pour piano, op. 116 is composed in a particularly intimate and despairing way. Through a complete Schenkerian analysis and outline of the musical framework of op. 116—Jongen's last collection of piano pieces—this dissertation sheds light on the technique, imagination, and uniqueness of Jongen's WWII-period piano compositions. More specifically, this research outlines the deep-level tonal and formal structures, investigates the cryptic semantic meaning and intimate personal expression, and defines the aesthetic achievements of Jongen's Twenty-four Little Preludes in All Keys for Piano, op. 116.
42

Rapport aux Anciens et évolution de la polémique contre le moyen-platonisme dans les Discours platoniciens (Or. II-IV) d'Aelius Aristide

Voyer, Martin 22 June 2021 (has links)
Les Discours platoniciens (Or. II-IV) d'Aelius Aristide – le Pour la rhétorique (Or. II), le À Capiton (Or. IV) et le Pour les Quatre (Or. III) – ont le plus souvent été étudiés dans leur ensemble comme s'ils formaient une seule œuvre rédigée dans les mêmes circonstances. D'un autre côté, les relations qui unissent ces discours au moyen-platonisme n'ont pas donné lieu à des recherches approfondies. La thèse vise donc à mieux comprendre ces discours dans leur progression en réinscrivant la polémique dans le contexte du moyen-platonisme. Les deux axes privilégiés concernent le rapport à la tradition culturelle grecque : le premier est l'attitude préconisée et observée à l'égard de Platon et des Anciens ; le second se compose des principes régissant l'exégèse des textes du philosophe. Il s'agit aussi de mieux cerner la spécificité et la pertinence du Pour les Quatre, le discours le moins étudié du corpus. L'approche diachronique dicte la structure de la thèse, les discours étant étudiés dans leur ordre de rédaction. Concernant le premier axe, celui de l'attitude à l'égard des Anciens, le type de rapport qui est préconisé et mis en pratique demeure essentiellement le même à travers les trois discours : Aristide promeut la rivalité et il la met ouvertement en pratique avec Platon. Des infléchissements, qu' il est possible d'expliquer à la lumière du moyen-platonisme, apparaissent toutefois avec chaque texte. Le Pour la rhétorique exalte l'audace qui est nécessaire pour contredire un Ancien par opposition à la lâcheté de ceux – les platoniciens – qui n'osent s'opposer à une figure d'autorité. À partir du À Capiton, l'insistance porte sur la retenue et le respect qui devraient caractériser le traitement des Anciens. Du À Capiton au Pour les Quatre, c'est l'écriture qui épouse de plus en plus une rhétorique de la retenue tout en intensifiant la gravité des reproches. Le Pour les Quatre apparaît comme l'aboutissement de l'entreprise aristidienne car il fait du rapport à la tradition un thème majeur et structurant, en plus de clarifier l'enjeu soulevé par cette problématique à l'époque impériale, soit la survie de l'hellénisme. Les Discours platoniciens sont très cohérents en ce qui concerne le second axe, l'exégèse des dialogues de Platon, car ils signalent tous l'insuffisance des catégories médioplatoniciennes. Toutefois, seul le Pour les Quatre s'attaque au Gorgias à partir de ces catégories. C'est aussi dans ce discours qu'un effet spéculaire constant apparaît entre Platon et Aristide : le premier corromprait des lecteurs par ses critiques simples et sans retenue, tandis que le second procèderait à l'inverse. La spécificité du Pour les Quatre apparaît aussi à travers l'importance accrue qu'y prennent les actions visant la préservation de l'hellénisme. Sur ce point, l'action politique et la pédagogie des Quatre sont représentées de manière à recouper dans leurs principes l'éducation qu'Aristide entend mettre en œuvre à travers son discours. Dans les deux cas, le succès s'explique notamment par la capacité d'adaptation aux circonstances, qu'Aristide manifeste en modifiant son style en fonction des vertus qu'il exalte. Il se constitue ainsi en modèle des vertus qu'il loue et de leur application appropriée selon les circonstances. Les Quatre ont protégé la Grèce contre les barbares : Aristide tente de les imiter sur le plan culturel, à une époque où la paideia est à ses yeux menacée par des philosophes populaires. / Aelius Aristides' Platonic orations (Or. II-IV) – the In Defense of Oratory (Or. II), the To Capito (Or. IV), and the In Defense of the Four – have mostly been studied synchronically, as if they formed a single work written under the same circumstances. Moreover, the relations between these orations and Middle Platonism have not yet been thoroughly investigated. This thesis aims to better understand the progression of these orations by tying the polemic with the context of Middle Platonism. The two privileged lines of inquiry concern the relationship with the Greek cultural tradition: the first is the attitude advocated and observed towards Plato and the Ancients; the second is composed of the principles governing the exegesis of this philosopher's texts. It is also about better defining the specificity and relevance of the In Defense of the Four, the least studied oration of the corpus. The diachronic approach dictates the structure of the thesis: the orations are studied in their writing order. Regarding the first line of inquiry, that of the attitude towards the Ancients, the type of relationship that is advocated and put into practice remains essentially the same across the three orations: Aristides promotes rivalry and he carries it out quite openly with Plato. However, changes, that can be explained in the light of Middle Platonism, appear with each text. In Defense of Oratory exalts the audacity that is required to contradict an Ancient as opposed to the cowardice of those Platonists who dare not oppose a figure of authority. From the To Capito onwards, the emphasis is on the restraint and respect that should characterize the treatment of the Ancients. From this oration to the last one, In Defense of the Four, the writing increasingly embraces a rhetoric of restraint while increasing the intensity of the reprimands. The In Defense of the Four appears to be the culmination of the Aristidian project because it transforms the relation with tradition in a major and structuring theme, in addition to clarifying the issue raised by this question during the imperial era, namely the survival of Hellenism. The Platonic orations are consistent with regard to the second line of inquiry, the exegesis of Plato's dialogues, because they all point out the insufficiency of the Middle Platonic categories. However, only the In Defense of the Four tackles the Gorgias on the basis of these categories. It is also in this discourse that a constant specular effect between Plato and Aristides appears: the former would corrupt readers with straightforward and unrestrained critiques, whereas the latter tries to do the exact opposite. The specificity of the In Defense of the Four also manifests itself in the increasing importance taken by the theme of the actions aimed at preserving Hellenism. On this point, the political actions and the pedagogy of the Four are represented in such a way as to intersect in their principles the education that Aristides intends to implement through his speech. In both cases, success depends on the ability to adapt to circumstances, a skill which Aristides manifests by modifying his style according to the virtues he exalts. In this way, he himself becomes a model of the virtues he praises and their appropriate application according to the circumstances. The Four protected Greece against the barbarians: Aristides tries to imitate them culturally, at a time when paideia is, in his eyes, threatened by popular philosophers.
43

Développement d'un dispositif intégré de photodétection de grande sensibilité avec discrimination spectrale pour les laboratoires sur puce

Courcier, Thierry January 2014 (has links)
Résumé : Ce travail de thèse a pour but de développer un dispositif intégré de photodétection pour des applications biomédicales nécessitant une grande sensibilité de détection et une discrimination spectrale (sélectivité). Ce dispositif peut être appliqué, par exemple, à la mesure simultanée de plusieurs marqueurs fluorescents dans les laboratoires sur puce mettant en œuvre de très faibles volumes de réactifs (inférieurs au microlitre). Le travail de thèse se focalise sur la conception, la réalisation et le test de ce dispositif intégré de photodétection. Ce travail se décline selon deux axes principaux : d’une part, la conception d’un photodétecteur CMOS avec préamplificateurs intégrés, et d’autre part la conception, la réalisation et la caractérisation de filtres optiques intégrés performants pour la détection de fluorescence. Le dispositif de détection conçu implémente un photodétecteur à quatre jonctions enterrées (Buried Quad Junction photodetector – BQJ) et un étage de préamplification de charge pour le traitement simultané des quatre sorties de ce photodétecteur. L’ensemble a été fabriqué en technologie Haut-Voltage CMOS Teledyne-DALSA 0,8μm. Son fonctionnement a été démontré et ses performances, notamment en termes de bruit et de sensibilité, ont été caractérisées. En parallèle, des filtres optiques coupe-bande ont été développés à l’aide d’un procédé compatible avec la technologie CMOS utilisée pour le photodétecteur. Ainsi, le dépôt de ces filtres sur le photodétecteur pourra être intégré dans le process de fabrication industriel. Les filtres interférentiels développés sont fabriqués en alternant des dépôts de couches minces de nitrure et d’oxyde de silicium par PECVD. La mesure des indices optiques de ces matériaux a été utilisée pour optimiser ces filtres à partir de simulations. Les filtres déposés sur lame de verre ou sur le photodétecteur BQJ ont été caractérisés. Des méthodes de traitement des signaux spécifiques pour le BQJ sont également proposées pour améliorer la sensibilité et/ou la sélectivité de détection. Leurs performances ont été évaluées. Enfin, des mesures de fluorescence avec le système de photodétection conçu ont été réalisées sur des mélanges de nanocristaux fluorescents (quantum dots) ou de fluorophores organiques. Ces résultats préliminaires permettent de valider le fonctionnement applicatif du système de photodétection développé. // Abstract : This thesis aims to develop an integrated photosensor device for biomedical applications requiring high detection sensitivity and spectral discrimination (selectivity). For example, this system can be applied to mesure simultaneous emissions of several fluorescent labels in lab-on-a-chip implementing very small volumes of reagents (less than one microliter). The thesis focuses on the design, implementation and testing of this integrated photodetector device. The work is divided in two main parts: first, the design of a CMOS photodetector with integrated preamplifiers, and secondly the design, realization and characterization of integrated optical filters for fluorescence detection. The detection device implements a Buried Quad Junction photodetector (BQJ) and charge sensitive preamplifiers for the simultaneous treatment of its four outputs. The chip was made in 0.8μm High Voltage CMOS technology from Teledyne-DALSA. Its operation has been demonstrated and its performances, especially in terms of noise and sensitivity, have been characterized. In parallel, optical notch filters have been developed using a process compatible with the CMOS technology used for the photodetector fabrication. Thus, deposition of these filters on the photodetector can be integrated during industrial process. Developed interference filters are made by alternating deposition of thin layers of nitride and silicon oxide by PECVD. Measurements of refractive index of these materials were used to optimize these filters through simulations. The filters implemented on a glass cover or on the BQJ photodetector were characterized. Signal processing methods specific to BQJ are also proposed to improve the detection’s sensitivity and/or selectivity. Their performances were evaluated. Finally, fluorescence measurements with the designed photodetection device were performed on mixtures of fluorescent nanocrystals (quantum dots) or of organic fluorophores. These preliminary results validate the performances in terms of photodetection of the designed integrated photodetection device.
44

Microscopie par diffusion cohérente Raman<br />CARS: Application à l'imagerie des milieux<br />biologiques

Djaker, Nadia 20 October 2006 (has links) (PDF)
La microscopie par diffusion Raman Coh´erente Anti-Stokes (CARS) est une<br />m´ethode r´ecente d'imagerie dont le contraste provient de l'excitation r´eso-<br />nante s´elective de vibrations mol´eculaires intrins`eques d'une liaison ou d'un<br />ensemble de liaisons chimiques. Cette technique pr´esente l'avantage de s'af-<br />franchir de tout marqueur fluorescent qui peut ˆetre toxique pour un orga-<br />nisme biologique vivant. Elle permet aussi d'avoir une tr`es grande sensibilit´e<br />et une forte r´esolution spatiale, comparable `a celle de la microscopie confo-<br />cale. Le travail de cette th`ese concerne la r´ealisation d'un microscope CARS,<br />et sa mise en application `a diff´erents domaine de l'imagerie bio-m´edicale. Des<br />´etudes ont ´et´e men´ees d´emontrant les potentialit´es de cet outil, ainsi que sa<br />caract´erisation dans le domaine spatiale et spectral.
45

Microscopie de mélange à quatre ondes résolue en polarisation: lecture des symétries structurales et vibrationnelles dans les milieux moléculaires

Munhoz, Fabiana 13 December 2010 (has links) (PDF)
One of the greatest challenges in nonlinear optics microscopy is the search for new contrast mechanisms. This is one of the reasons of the increasing interest in polarimetric nonlinear optics in the last couple of decades. In this work we have explored the potential of four-wave mixing in probing vibrational and structural symmetries in molecular media. In particular, we have been concerned with coherent Raman scattering (CRS), either at resonance or not. We have developed a theoretical model allowing to determine the structures of the susceptibility tensors from symmetry considerations, involving both the spatial structure of the medium and the vibration of specific molecular modes. Experimental results on isotropic sample, crystals and biomolecular assemblies were successfully achieved. Polarimetric measurements at resonance provide information on the symmetry of the addressed vibrational modes and on departure from Kleinman symmetry conditions. Nonresonant polarimetric measurements are able to reveal departure from isotropy in cubic crystals and the symmetry order and orientation of molecular distribution in biomolecular assemblies, such as collagen fibers. In particular, we have shown that higher-order molecular symmetries can only be probed by high-order nonlinear optical processes. Finally, this work has demonstrated the great potential of polarimetric four-wave mixing as a powerful contrast mechanism, providing structural selectivity in microscopy imaging. When it is further associated with a resonant process (such as CRS), it provides also chemical selectivity, allowing a complete description of the sample, involving both structural and vibrational symmetries.
46

Stabilité dynamique des véhicules légers tout-terrain. Nouvelles solutions. Application aux véhicules légers de type quad

Bouton, Nicolas 25 November 2009 (has links) (PDF)
La problématique de cette thèse réside dans l'étude et le maintien de la stabilité dynamique latérale des Véhicules Légers Tout Terrain (VLTT) évoluant en milieu naturel. Elle s'attache plus particulièrement au développement d'indicateurs de risque pour l'aide à la conduite ainsi qu'au développement de systèmes de sécurité actifs dédiés aux VLTT, avec comme cadre expérimental privilégié, l'application à la stabilité latérale des véhicules quadricyles à moteur communément appelés quads. Cette thèse propose des algorithmes de calcul d'un indicateur de risque et de commande globaux, exploitant trois domaines connexes de la robotique : la modélisation, l'observation et la commande. Un modèle dynamique, intégrant les glissements et le comportement du pilote, est d'abord proposé afin de caractériser le renversement latéral de l'engin au travers du calcul et de l'anticipation de Transfert de Charge Latéral (TCL). Des observateurs capables d'estimer en temps réel l'adhérence sont utilisés pour alimenter ce modèle. Enfin une loi commande prédictive permet d'assurer la stabilité latérale de l'engin, validée par de nombreuses expérimentations
47

Études expérimentales de lasers microchips à émission continue mono-fréquence à 553 nm et à 561 nm, de puissance supérieure à 200 mW / Study of microchip lasers based on Nd : YAG frequency-doubled, diode-pumped and emitting in continuous single-frequency at 553 nm or 561 nm with an output power exceeding 200 mW

Chauzat, Corinne 08 January 2014 (has links)
Le remplacement des lasers à colorant émettant dans la gamme 550-570 nm, à l'aide de lasers solides, représente un véritable enjeu industriel. Les applications sont multiples tant dans le domaine de la recherche biomédicale que dans celui de la métrologie. Quelques solutions ont été développées à 561 nm et à 553 nm. Néanmoins, elles ne permettent pas de fournir des lasers intégrables parfaitement mono-fréquences émettant en continu un faisceau gaussien, d'une puissance supérieure ou égale à 200 mW. Dans ces travaux, nous proposons une étude théorique et expérimentale de cavités lasers solides monolithiques à base de Nd:YAG pompé par diode, doublé en fréquence en intra-cavité, à l'aide d'un cristal non-linéaire de KTP. Ces cavités, constituées de plusieurs cristaux, sont contactées par adhérence moléculaire. Elles ne contiennent aucune optique de mise en forme des faisceaux et présentent la particularité de comporter un double filtre de Lyot. Nous présentons les résultats obtenus avec des cavités émettant à 561 nm pour des puissances supérieures ou égales à 300 mW. Puis, après une étude statistique et une analyse des résultats de test de ces cavités à long terme (> 6000 heures), nous discutons des problèmes éventuels de fiabilité et nous suggérons des axes d'amélioration. Ayant réussi à faire osciller, pour la première fois, la raie à 1106 nm du Nd:YAG, nous montrons ensuite la faisabilité d'un laser compact mono-fréquence continu à 553 nm, émettant une puissance de 200 mW à 500 mW avec un rendement de conversion pompe/laser visible de l'ordre de 19 %. Pour conclure, nous montrons qu'il est possible, dans des cavités de ce type, de faire osciller des raies Raman issues des raies fondamentales et de les doubler en fréquence en intra-cavité. Nous ouvrons ainsi la porte à toute une famille de lasers solides émettant dans la gamme 540-600 nm. / Replacement of dye lasers emitting in the range 550-570 nm, using solid state lasers, is a real industrial issue. There are many applications both in the field of biomedical research than in metrology. Some solutions have been developed for 561 nm and 553 nm. However, they do not provide fully integrated lasers emitting single-frequency continuous Gaussian beam with a power equal or up to 200 mW. In this work, we propose a theoretical and experimental study of solid monolithic cavity lasers based on Nd:YAG diode-pumped, frequency-doubled intra-cavity, using a non-linear crystal of KTP. These cavities, consisting of several crystals, are contacted by molecular adhesion. They contain no optical layout of the beams and they have the particularity of including a double Lyot filter. We present the results obtained with those cavities emitting at 561 nm for powers greater than 300 mW. Then, after a statistical study and analysis of test results of these cavities in the long term (> 6000 hours), we discuss about the potential problems of reliability and we suggest areas for improvement. For the first time, we show that the line at 1106 nm of the Nd: YAG can oscillate in this type of cavity. Then we demonstrate the feasibility of a compact single-frequency laser at 553 nm continuously, emitting a power of 200 mW to 500 mW with a conversion efficiency of pump / visible laser of about 19%. Finally, we show that it is possible, in cavities of this type, to oscillate the Raman lines from the lines of the fundamental and doubled frequency in intra-cavity. We open the door to a whole family of solid state lasers emitting in the range of 540-600 nm.
48

Effets de la combustion du noir de carbone sur l'adsorption des NOx sur un catalyseur quatre voies / 4 way catalysts, Deactivation of the NOx storage trap function by soot

Klein, Jennifer 20 October 2011 (has links)
Récemment, les constructeurs automobiles se sont intéressés au développement des catalyseurs appelés quatre voies, destinés à diminuer simultanément les émissions polluantes des moteurs diesels par l'intermédiaire d'un seul monolithe catalytique. Dans cet objectif, plusieurs études ont montré que la capacité de stockage des NOx de ces catalyseurs est inhibée par la présence de suies. Les travaux présentés dans ce manuscrit s'inscrivent dans la compréhension des phénomènes en cause. Les résultats obtenus montrent que la présence de noir de carbone entraîne une diminution de la stabilité des nitrates adsorbés par les systèmes catalytiques étudiés et, ainsi, de leur capacité de stockage des NOx. Ce phénomène a été attribué à une réduction des espèces nitrates adsorbées à la surface des matériaux par les particules de carbone adjacentes. La présence d'une particule Pt à proximité d'un site de carbone favorise la formation de complexes oxygénés de surface, limitant l'effet réducteur du carbone envers les nitrates adsorbés. La perte de capacité d'adsorption des NOx des catalyseurs étudiés, observée lors de leur mise en contact avec du noir de carbone, s'est révélée irréversible à l'issue de l'oxydation du carbone. La caractérisation des matériaux par microscopie à transmission (MET) a révélé une modification importante de la structure des matériaux. Un frittage des particules de platine et une modification de la structure des particules de Ba entraînent en effet la perte irréversible de l'activité des matériaux vis-à-vis de l'adsorption des NOx. / Recently, car manufacturers have developed "4 way" catalytic converters in order to couple hydrocarbon and CO oxidation, soot combustion and DeNOx fonctions on a single monolith. Several studies showed that the NOx storage capacity of NSR catalysts is reduced in the presence of soot. The aim of this work is to investigate the effect of carbon­ NSR catalyst contact on the ability of the catalyst to store NOx. The results show that the presence of carbon black in the catalytic bed involves a decrease of adsorbed nitrates stability and of the NOx storage capacity of materials. It is proposed that the proximity of the carbon particles and NOx adsorbents sites leads to a reduction of the stored nitrates species. The decrease of the NOx storage capacity is Jess important when platinum is present in the catalytic material composition. In agreement with previous studies on the catalytic combustion of soot, it is suggested that platinum increases the number of surface-oxygen complexes -C(O), which thus led to a decrease in the reducing character of carbon. Our study reveals that the deactivation of the NOx storage activity due to carbon-catalyst contact is an irreversible phenomena, and thus even when all carbon is burnt. Characterization of materials by transmission electron microscopy (TEM) showed that sintering of the platinum particles and a structural modification of the barium particles occurs after that the catalysts was in contact with carbon. The decrease in the NOx storage activity of the materials is then assigned to a lesser proximity of the oxidizing sites (Pt) and adsorption sites (Al or Ba).
49

Développement d'un dispositif intégré de photodétection de grande sensibilité avec discrimination spectrale pour les laboratoires sur puce / Development of an integrated photosensor device for lab on chip applications requiring high detection sensitivity and spectral discrimination

Courcier, Thierry 17 June 2014 (has links)
Ce travail de thèse a pour but de développer un dispositif basé autour d'un dispositif intégré de photodétection pour des applications biomédicales nécessitant une grande sensibilité de détection et une discrimination spectrale (sélectivité). Ce dispositif peut être appliqué, par exemple, à la mesure simultanée de plusieurs marqueurs fluorescents dans les laboratoires sur puce mettant en œuvre de très faibles volumes de réactifs (inférieurs au microlitre). Le travail de thèse se focalise sur la conception, la réalisation et le test de ce dispositif intégré de photodétection. Ce travail se décline selon deux axes principaux : d'une part, la conception d'un photodétecteur CMOS avec préamplificateurs intégrés, et d'autre part la conception, la réalisation et la caractérisation de filtres optiques intégrés performants pour la détection de fluorescence / This thesis aims to develop a system based around an integrated photosensor device for biomedical applications requiring high detection sensitivity and spectral discrimination (selectivity). For example, this system can be applied to mesure simultaneous emissions of several fluorescent labels in lab-on- a-chip implementing very small volumes of reagents (below the microliter). The thesis focuses on the design, implementation and testing of this integrated photodetector device. The work is divided in two main parts: first, the design of a CMOS photodetector with integrated preamplifiers, and secondly the design, realization and characterization of integrated optical filters for fluorescence detection
50

Amplification de l'énergie d'une source VUV cohérente à 125 nm dans une plume d'ablation de mercure

Philippet, Laurent 12 November 2009 (has links) (PDF)
Ce travail est consacré à l'étude d'une technique originale basée sur l'ablation laser du mercure liquide dans le but d'augmenter l'efficacité de conversion d'une source VUV cohérente à 125 nm. Ce rayonnement est obtenu par somme de fréquences résonnante à deux photons (6s 1S0 -> 7s 1S0) dans une vapeur de mercure à température ambiante. Les paramètres expérimentaux tels que la géométrie de la plume d'ablation, l'énergie des faisceaux fondamentaux, la densité d'énergie du laser d'ablation et la pression d'un gaz neutre (ici l'argon qui permet de confiner la plume) ont été optimisées et ont amené une amplification d'un ordre de grandeur (jusqu'à deux ordres de grandeur pour des intensités réduites) soit une énergie de 250 nJ. Afin de mieux comprendre les phénomènes physiques mis en jeu, une caractérisation complète de la plume a été menée grâce à des expériences d'imagerie et de spectroscopie résolues en temps. La luminescence propre de la plume ainsi que la fluorescence induite par l'absorption de deux photons (sur la raie 6s 1S0 -> 7s 1S0) nous ont permis de connaître la composition de la plume, d'estimer sa température, les vitesses des différentes espèces et la densité d'atomes à l'état fondamental. Un étalonnage réalisé à partir du signal de somme de fréquences a permis d'obtenir une cartographie du nombre absolu d'atomes de mercure dans l'état fondamental. Nous avons également montré que la manipulation du faisceau VUV est rendue plus simple dans une boîte à gants (ici remplie d'argon) que dans le vide. Une structure périodique, de 100 µm de pas, a été réalisée par lithographie sur du PMMA et des premiers pas vers la lithographie par interférométrie ont été franchis.

Page generated in 0.0265 seconds