• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 70
  • 5
  • 1
  • Tagged with
  • 76
  • 60
  • 40
  • 27
  • 19
  • 17
  • 11
  • 10
  • 9
  • 9
  • 8
  • 8
  • 7
  • 7
  • 6
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
51

Desarrollo de nueva formula para estimar estatura en población chilena adulta, a partir del largo del fémur

Abarca Labra, Violeta A. 08 1900 (has links)
Introducción: La estimación de la estatura a partir del largo del fémur es relevante para distintos campos profesionales como ciencias forenses e identificación y salud pública. Problema: La población chilena pasa por un cambio secular pondo-estatural y las fórmulas utilizadas para estimar estatura desde largos óseos no se adecúan a la realidad actual. Asimismo es difícil acceder a largos óseos y/o muestras actuales esqueletizadas con estatura conocida y debidamente estimada. Objetivo Gral.: El objetivo de esta investigación fue desarrollar una nueva fórmula para estimar estatura a partir del largo del fémur en población chilena actual, utilizando imágenes DEXA (Absorciometría de Doble Energía Radiológica). Metodología: Estudio transversal y muestra de 176 individuos (95 hombres y 81 mujeres entre 16-18 años) provenientes de una cohorte estudiada por el Instituto de Nutrición y Tecnología de los Alimentos (INTA) y la Universidad de Michigan (Financiado por Proyecto NIH), cuya estatura es conocida y poseen imágenes DEXA de cuerpo entero. El largo del fémur se estimó mediante el método Linear Pixel Counter (LPC) a partir de imágenes DEXA (Lunar iDXA EnCORE 2011 Versión 13.60.033 Copyright © 1998-2010; Lunar DPX-LIQ; Lunar Corp., Madison, WI, USA). Variable dependiente: Estatura. Variable independiente: Largo máximo del fémur. Resultados: Nuevo modelo de regresión lineal simple para estimar estatura a partir del largo del fémur en población chilena actual. Conclusiones: La estatura estimada mediante la nueva fórmula no presenta diferencias significativas respecto de la estatura real del individuo (Suma de Rangos de Wilcoxon p>0,05). Las otras fórmulas tradicionalmente empleadas: Trottrer y Gleser (1958); Genovés (1967); Del Angel y Cisneros (2004); Ross y Manneschi (2011 y 2012) presentan al menos un sexo cuya estatura difiere significativamente de la estatura real del individuo (Suma de Rangos de Wilcoxon p<0,05). Palabras claves: Estimación de estatura, largo femoral, Absorciometría de Doble Energía Radiológica, cambio secular, antropología.
52

Revisión crítica: evidencias en la utilización de equipos de protección para reducir la radiación en el personal de sala de operaciones

Cerdan Tello, Jacqueline Giovanna January 2022 (has links)
El trabajo académico denominado "Evidencias en la Utilización de Equipos de Protección para reducir la Radiación en el Personal de Sala de Operaciones", tuvo como objetivo: describir la utilización de los equipos de protección en la reducción de los niveles de radiación en el personal de sala de operaciones. Se desarrolló un tipo de investigación secundaria con una metodología de Enfermería Basada en Evidencias, formulando la pregunta clínica PICOT: ¿Cuáles son las evidencias en la utilización de los equipos de protección para reducir los niveles de radiación en el personal de sala de operaciones? Para la búsqueda bibliográfica se emplearon buscadores como Pubmed, Science, Google Académico y SciELO, encontrando un total de 10 investigaciones que fueron evaluadas a través de la guía de validación de Gálvez Toro, seleccionando el estudio Eficacia del uso de Protectores para reducir los niveles de Radiación en el Personal de Sala de Operaciones, evaluada con la guía PRISMA para determinar su calidad metodológica. En respuesta a la pregunta clínica, se encontró evidencia de que el empleo correcto y completo de gorros, gafas, collarines tiroideos, mandiles son eficaces para la radioprotección en el personal de salud. Existe también evidencia del empleo de protección pélvica plomada en el paciente sometido a cirugía, con el objetivo de reducir la radiación dispersa. Según la clasificación SIGN, la revisión tuvo un nivel de evidencia I -, dado a la poca información de sesgos en el estudio, además tuvo un grado de recomendación A, en base al sistema de clasificación GRADE.
53

Caracterização de um dispositivo de ensaio para determinação da camada semiredutora e da filtração com equivalência de qualidade de acordo com a norma ABNT NBR IEC 60601-1-3 / Characterization of a test device for determination of the half value layer and of filtration with quality equity of materials in accordance with standard ABNT NBR IEC 60601-1-3

Vlamir Viana 28 June 2012 (has links)
A motivação deste trabalho foi o desenvolvimento e validação de um dispositivo para realizar os testes estabelecidos na ABNT NBR IEC 60601-1-3 nas versões publicadas de 2001[1] e 2011[2]. A finalidade dos ensaios é determinar a camada semirredutora - CSR (Half Value Layer - HVL) e a filtração com equivalência de qualidade, em mmAl, dos materiais que interceptam o feixe de raios X desde a sua emissão até o dispositivo receptor de imagem de raios X. Esta filtração inclui os materiais presentes no conjunto fonte de radiação X, formado pela cúpula de proteção radiológica com o tubo de raios X inserido, pelo sistema de colimação (filtração inerente) e pelos materiais presentes nos suportes de pacientes, como mesa e bucky mural sendo que ambos incorporam dispositivo receptor de imagem que também é avaliado. No desenvolvimento foi levada em consideração a rotina da execução do ensaio, com a finalidade de diminuir ao máximo a interação do operador com o sistema, a fim de reduzir o fator humano na execução, refletindo diretamente na incerteza de medição, na diminuição do tempo de execução e na segurança radiológica. O dispositivo desenvolvido foi validado com relação aos seguintes aspectos: a) Influência do dispositivo trocador de filtros quanto ao posicionamento e distribuição dos filtros; b) Influência da pureza dos filtros de alumínio utilizados no dispositivo, e a c) Comparação entre os ensaios realizados com dispositivo de ensaio desenvolvido com relação aos ensaios realizados com um gerador de raios X de referência. / The motivation of this work was the development and validation of a device to perform the tests established by ABNT NBR IEC 60601-1-3 versions published in 2001 [1] and 2011 [2]. The purpose of the tests is to determine the half-value layer HVL and filtration with equivalent filtration quality in mmAl, materials that intercept the X-ray beam from their emission to the X-ray image receiving device. This filtration includes all the materials present in radiation source assembly, formed by the x-ray tube housing with x-ray tube inserted, the collimator (inherent filtration) and by materials present in the patients support, as Table and wall bucky, both incorporate image receiving device which is also evaluated. In the development was taken in consideration the routine of tests execution routine, in order to reduce the operator interaction with the system and in order to reduce the human factor in the execution, reflecting directly on the measurement uncertainty, in the runtime reduction of the runtime and radiation safety. The device was validated with respect to: a) Effect of positioning and distribution of the filters in the filter changer device; b) Influence of purity of the aluminum filter used in the device, and c) Comparison tests carried out with the testing device with respect to the tests carried out with a reference X-ray generator.
54

Caracterização de um dispositivo de ensaio para determinação da camada semiredutora e da filtração com equivalência de qualidade de acordo com a norma ABNT NBR IEC 60601-1-3 / Characterization of a test device for determination of the half value layer and of filtration with quality equity of materials in accordance with standard ABNT NBR IEC 60601-1-3

Viana, Vlamir 28 June 2012 (has links)
A motivação deste trabalho foi o desenvolvimento e validação de um dispositivo para realizar os testes estabelecidos na ABNT NBR IEC 60601-1-3 nas versões publicadas de 2001[1] e 2011[2]. A finalidade dos ensaios é determinar a camada semirredutora - CSR (Half Value Layer - HVL) e a filtração com equivalência de qualidade, em mmAl, dos materiais que interceptam o feixe de raios X desde a sua emissão até o dispositivo receptor de imagem de raios X. Esta filtração inclui os materiais presentes no conjunto fonte de radiação X, formado pela cúpula de proteção radiológica com o tubo de raios X inserido, pelo sistema de colimação (filtração inerente) e pelos materiais presentes nos suportes de pacientes, como mesa e bucky mural sendo que ambos incorporam dispositivo receptor de imagem que também é avaliado. No desenvolvimento foi levada em consideração a rotina da execução do ensaio, com a finalidade de diminuir ao máximo a interação do operador com o sistema, a fim de reduzir o fator humano na execução, refletindo diretamente na incerteza de medição, na diminuição do tempo de execução e na segurança radiológica. O dispositivo desenvolvido foi validado com relação aos seguintes aspectos: a) Influência do dispositivo trocador de filtros quanto ao posicionamento e distribuição dos filtros; b) Influência da pureza dos filtros de alumínio utilizados no dispositivo, e a c) Comparação entre os ensaios realizados com dispositivo de ensaio desenvolvido com relação aos ensaios realizados com um gerador de raios X de referência. / The motivation of this work was the development and validation of a device to perform the tests established by ABNT NBR IEC 60601-1-3 versions published in 2001 [1] and 2011 [2]. The purpose of the tests is to determine the half-value layer HVL and filtration with equivalent filtration quality in mmAl, materials that intercept the X-ray beam from their emission to the X-ray image receiving device. This filtration includes all the materials present in radiation source assembly, formed by the x-ray tube housing with x-ray tube inserted, the collimator (inherent filtration) and by materials present in the patients support, as Table and wall bucky, both incorporate image receiving device which is also evaluated. In the development was taken in consideration the routine of tests execution routine, in order to reduce the operator interaction with the system and in order to reduce the human factor in the execution, reflecting directly on the measurement uncertainty, in the runtime reduction of the runtime and radiation safety. The device was validated with respect to: a) Effect of positioning and distribution of the filters in the filter changer device; b) Influence of purity of the aluminum filter used in the device, and c) Comparison tests carried out with the testing device with respect to the tests carried out with a reference X-ray generator.
55

Informatização e unificação dos programas de proteção radiológica: monitoramento das radiações ionizantes e sua otimização / Web-based system to unify the radiological protection programs: ionizing radiation monitoring and optimization

Levy, Denise Sahyun 25 August 2015 (has links)
Um programa de monitoramento para fins de proteção radiológica deve mostrar como ele auxilia na obtenção e demonstração de um grau de proteção adequado e comprovar que as condições de trabalho continuam satisfatórias com o transcorrer do tempo. Para o controle operacional das exposições à radiação ionizante em qualquer local de trabalho, a Comissão Internacional de Proteção Radiológica (CIPR) recomenda um programa de proteção radiológica operacional, proporcional ao grau de risco, para garantir o gerenciamento efetivo das medidas necessárias para se satisfazer o principio da otimização. O presente trabalho de pesquisa tem como premissa o potencial das Tecnologias da Informação e Comunicação (TIC) como ferramenta para a comunicação e disseminação do conhecimento em Proteção Radiológica. O trabalho inclui a informatização da filosofia e técnica do monitoramento e sua otimização, unificando e inter-relacionando informações advindas de diversas publicações nacionais e internacionais, oferecendo às instalações radiativas brasileiras um veículo completo para informação e pesquisa, que permite dimensionar os esforços de otimização tornando-os eficazes e justificados. O sistema oferece ainda tópicos de discussões no intuito de ampliar o repertório dos profissionais do campo da proteção radiológica, suscitando novas reflexões a favor da segurança. Trata-se dos temas desenvolvidos nesta tese, a saber: a necessidade de um monitoramento auditor e discussões mais aprofundadas sobre as exposições potenciais. As reflexões propostas na presente tese vêm ao encontro das novas exigências internacionais, propondo ações passíveis de serem incorporadas na prática laboral. Dentro dos princípios da proteção radiológica, a implementação de um programa de monitoramento auditor permite avaliar se os critérios e ações previamente estabelecidas pelo Serviço de Proteção Radiológica são ou não atendidos, se foram implementados com eficácia e se permanecem adequados. Os fatos resultantes dos procedimentos de auditoria auxiliam a detectar deficiências no processo, possibilitando conclusões e recomendações diante de possíveis fatores desencadeadores de exposições indevidas. Por meio de exames sistemáticos das atividades realizadas em cada tipo de monitoramento, a auditoria infere segurança ao processo, respaldando o trabalhador na realização do monitoramento relacionado com a tarefa e respaldando a instalação, que empreende ações responsáveis a favor da segurança. Em relação às exposições potenciais, somente duas publicações da CIPR são expressivas e desenvolvem o assunto. Entretanto, ainda que forneçam a fundamentação teórica, são incompletas em seus exemplos. Há uma grande falta de conhecimento das probabilidades de falhas, o que atualmente constitui um vasto campo de pesquisa da proteção radiológica. A presente tese propõe, a partir de árvores de falhas, caminhos que auxiliam a quantificar probabilisticamente a ocorrência das exposições potenciais e a probabilidade de se atingir um determinado valor da dose. Acreditamos que o potencial das TIC contribuirá largamente para a disseminação da informação para as instalações radiativas, estimulando o desenvolvimento neste país de grandes extensões territoriais, onde permanece um desafio oferecer o acesso à informação ao maior número de pessoas possível, minimizando custos e maximizando resultados. / A monitoring program for the purposes of radiological protection should demonstrate an adequate protection degree and prove that working conditions remain appropriate as time goes by. For operational control of exposures to ionizing radiation in any workplace, the International Comission on Radiation Protection (ICRP) recommends establishing a program of operational radiation protection, proportional to the risk, to ensure the effective management of all necessary measures to satisfy the principle of optimization. This research work focus on the potential value of Information and Communication Technologies (ICTs) to enhance communication and education on Radiological Protection throughout Brazil. The work includes the informatization of the monitoring policy and techniques, interrelating information currently scattered in several documents, providing Brazilian radioactive facilities a complete repository for research, consultation and information, which allows to size optimization efforts by technology, enabling them to be effective and justified. The content of monitoring programs involves not only the collection and interrelationship of existing information in the publications, but also new approaches from some recommendations, presenting some initiatives towards safety. In this sense, the two contents researched and expanded are: the need for an auditor monitoring and discussions on potential exposures. The recommendations proposed in this thesis meet the new international requirements stablished by the International Agency of Nuclear Energy (IAEA) and propose appropriate actions to be incorporated into labor practice. Respecting the scope of the principles of radiological protection, an auditing program permits to evaluate whether criteria and actions previously established by Radiological Protection Service are effectively implemented and remain appropriate as time goes by. The results of auditing procedures help to detect deficiencies in the process, enabling conclusions and recommendations, avoiding possible triggers of undue exposures. Through systematic examinations of activities in each type of monitoring, auditing attempt to ensure the process, supporting the employee in performing task-related monitoring and support the facility that choose responsible actions towards safety. Furthermore, regarding potential exposures, only two publications of ICRP develop expressively the issue. Even though these publications provide the fundamental theory, they are incomplete in their examples. There is still lack of knowledge of failure probabilities, which currently constitutes a broad research field in radiological protection. This research work proposes the development of fault trees, suggesting paths to quantify probabilistically the occurrence of potential exposures, as well as probabilities to reach a certain level of dose. We believe that the potential of ICT shall contribute greatly to provide information where it is needed, stimulating development in this large country where it is a strong challenge to ensure access to information to as many people as possible, minimizing costs and optimizing results.
56

Implantação de radiações de referência em máquina de raios X diagnóstico médico para fins de calibração de dosímetros pessoais

Annibal Theotonio Baptista Neto 28 February 2005 (has links)
Nenhuma / Campos de raios-x que estejam em conformidade com os requisitos internacionais de padronização nem sempre são disponíveis em uma região e, principalmente, em países em desenvolvimento. Esta situação tem sido usada como justificativa para a ausência de calibração de dosímetros pessoais e tem contribuído para a falta de confiabilidade nos programas de monitoração de trabalhadores expostos à radiação. Considerando a existência de diversas máquinas de raios-x em hospitais e a necessidade da calibração de dosímetros pessoais, este trabalho investigou a viabilidade da implantação de feixes de radiação-x destinados à calibração, comparáveis às radiações padronizadas internacionalmente, em uma máquina de raios-x diagnóstico médico. A implantação das radiações para calibração foi realizada com a determinação e comparação de parâmetros dos feixes de raios-x como a tensão do tubo, camada semi-redutora, uniformidade do campo de radiação, filtração e radiação espalhada. Os procedimentos, a geometria e as condições de irradiação foram, sempre, os mais simples possíveis para uma confiabilidade mínima dos resultados, nas condições usuais em hospitais. A viabilidade do uso dos feixes de radiação implantados foi confirmado através da análise do desempenho de um dosímetro pessoal do tipo filme, em calibrações e irradiações no Laboratório de Calibração de Dosímetros do Centro de Desenvolvimento da Tecnologia Nuclear, no Laboratório Nacional de Metrologia das Radiações Ionizantes e no University of Wisconsin Radiation Calibration Laboratory. Apesar da diferença entre os feixes de raios-x implantados e as radiações de referência, o desempenho do dosímetro pessoal atendeu aos requisitos para a monitoração individual. / X-ray fields that comply with international standardization requirements are not available in a world region, mainly in developing countries. This is used as an excuse for a lack of calibration of personal dosimeters and, consequently, a lack of reliability in individual monitoring programs applied to occupational workers under radiation exposures. Considering the availability of x-ray machines in many hospitals, this work studied the feasibility of implementing x-ray calibration beams in a medical diagnostic machine, which are comparable to international reference radiations for calibrating personal dosimeters. Implementation of the calibration beams was carried out by determining and comparing beam parameters as tube voltage, half-value layer, beam uniformity, filtration and scattered radiation. Procedures, geometry and exposure conditions were as simple as possible for a minimum reliability and close to the hospital conditions. The feasibility of the use of the implemented radiation beams was confirmed by analyzing the performance of a film personal dosimeter under calibration and irradiation at the Dosimeter Calibration Laboratory of the Centro de Desenvolvimento da Tecnologia Nuclear, the National Metrology Laboratory for Ionizing Radiations and the University of Wisconsin Radiation Calibration Laboratory. In spite of the difference between the implemented x-ray beams and the reference radiations, the performance of the film personal dosimeter complied with the accuracy requirements for individual monitoring.
57

Informatização e unificação dos programas de proteção radiológica: monitoramento das radiações ionizantes e sua otimização / Web-based system to unify the radiological protection programs: ionizing radiation monitoring and optimization

Denise Sahyun Levy 25 August 2015 (has links)
Um programa de monitoramento para fins de proteção radiológica deve mostrar como ele auxilia na obtenção e demonstração de um grau de proteção adequado e comprovar que as condições de trabalho continuam satisfatórias com o transcorrer do tempo. Para o controle operacional das exposições à radiação ionizante em qualquer local de trabalho, a Comissão Internacional de Proteção Radiológica (CIPR) recomenda um programa de proteção radiológica operacional, proporcional ao grau de risco, para garantir o gerenciamento efetivo das medidas necessárias para se satisfazer o principio da otimização. O presente trabalho de pesquisa tem como premissa o potencial das Tecnologias da Informação e Comunicação (TIC) como ferramenta para a comunicação e disseminação do conhecimento em Proteção Radiológica. O trabalho inclui a informatização da filosofia e técnica do monitoramento e sua otimização, unificando e inter-relacionando informações advindas de diversas publicações nacionais e internacionais, oferecendo às instalações radiativas brasileiras um veículo completo para informação e pesquisa, que permite dimensionar os esforços de otimização tornando-os eficazes e justificados. O sistema oferece ainda tópicos de discussões no intuito de ampliar o repertório dos profissionais do campo da proteção radiológica, suscitando novas reflexões a favor da segurança. Trata-se dos temas desenvolvidos nesta tese, a saber: a necessidade de um monitoramento auditor e discussões mais aprofundadas sobre as exposições potenciais. As reflexões propostas na presente tese vêm ao encontro das novas exigências internacionais, propondo ações passíveis de serem incorporadas na prática laboral. Dentro dos princípios da proteção radiológica, a implementação de um programa de monitoramento auditor permite avaliar se os critérios e ações previamente estabelecidas pelo Serviço de Proteção Radiológica são ou não atendidos, se foram implementados com eficácia e se permanecem adequados. Os fatos resultantes dos procedimentos de auditoria auxiliam a detectar deficiências no processo, possibilitando conclusões e recomendações diante de possíveis fatores desencadeadores de exposições indevidas. Por meio de exames sistemáticos das atividades realizadas em cada tipo de monitoramento, a auditoria infere segurança ao processo, respaldando o trabalhador na realização do monitoramento relacionado com a tarefa e respaldando a instalação, que empreende ações responsáveis a favor da segurança. Em relação às exposições potenciais, somente duas publicações da CIPR são expressivas e desenvolvem o assunto. Entretanto, ainda que forneçam a fundamentação teórica, são incompletas em seus exemplos. Há uma grande falta de conhecimento das probabilidades de falhas, o que atualmente constitui um vasto campo de pesquisa da proteção radiológica. A presente tese propõe, a partir de árvores de falhas, caminhos que auxiliam a quantificar probabilisticamente a ocorrência das exposições potenciais e a probabilidade de se atingir um determinado valor da dose. Acreditamos que o potencial das TIC contribuirá largamente para a disseminação da informação para as instalações radiativas, estimulando o desenvolvimento neste país de grandes extensões territoriais, onde permanece um desafio oferecer o acesso à informação ao maior número de pessoas possível, minimizando custos e maximizando resultados. / A monitoring program for the purposes of radiological protection should demonstrate an adequate protection degree and prove that working conditions remain appropriate as time goes by. For operational control of exposures to ionizing radiation in any workplace, the International Comission on Radiation Protection (ICRP) recommends establishing a program of operational radiation protection, proportional to the risk, to ensure the effective management of all necessary measures to satisfy the principle of optimization. This research work focus on the potential value of Information and Communication Technologies (ICTs) to enhance communication and education on Radiological Protection throughout Brazil. The work includes the informatization of the monitoring policy and techniques, interrelating information currently scattered in several documents, providing Brazilian radioactive facilities a complete repository for research, consultation and information, which allows to size optimization efforts by technology, enabling them to be effective and justified. The content of monitoring programs involves not only the collection and interrelationship of existing information in the publications, but also new approaches from some recommendations, presenting some initiatives towards safety. In this sense, the two contents researched and expanded are: the need for an auditor monitoring and discussions on potential exposures. The recommendations proposed in this thesis meet the new international requirements stablished by the International Agency of Nuclear Energy (IAEA) and propose appropriate actions to be incorporated into labor practice. Respecting the scope of the principles of radiological protection, an auditing program permits to evaluate whether criteria and actions previously established by Radiological Protection Service are effectively implemented and remain appropriate as time goes by. The results of auditing procedures help to detect deficiencies in the process, enabling conclusions and recommendations, avoiding possible triggers of undue exposures. Through systematic examinations of activities in each type of monitoring, auditing attempt to ensure the process, supporting the employee in performing task-related monitoring and support the facility that choose responsible actions towards safety. Furthermore, regarding potential exposures, only two publications of ICRP develop expressively the issue. Even though these publications provide the fundamental theory, they are incomplete in their examples. There is still lack of knowledge of failure probabilities, which currently constitutes a broad research field in radiological protection. This research work proposes the development of fault trees, suggesting paths to quantify probabilistically the occurrence of potential exposures, as well as probabilities to reach a certain level of dose. We believe that the potential of ICT shall contribute greatly to provide information where it is needed, stimulating development in this large country where it is a strong challenge to ensure access to information to as many people as possible, minimizing costs and optimizing results.
58

A flexibilização da competência e do processo normativo em relação à segurança e a proteção radiológica / The flexibility of competence and regulatory process regarding safety and radiation protection

Ana, Vanessa da 09 December 2016 (has links)
O uso e a aplicação cada vez mais constante da tecnologia nuclear consistente em áreas relacionadas à saúde, energia, industrial, bélica, agrícola, entre outras, faz com que haja a necessidade de uma regulamentação de acordo com os padrões de segurança e proteção radiológica internacionais. Dessa forma, utilizando-se de conceitos provenientes do Direito Constitucional, do Direito Ambiental e do Direito do Trabalho, o enfoque da presente pesquisa foi investigar a difícil questão da competência nuclear e a competência ambiental, a impossibilidade de legislar dos Estados, bem como a falta de regulamentação sobre Rejeitos radioativos. Para tanto, foram atualizados e revisados critérios e métodos de interpretação constitucional para solucionar possíveis antinomias jurídicas advindas de múltipla positivação de normas pelos entes federados que dificultam tanto o asseguramento quanto o aprimoramento da Proteção radiológica do trabalhador e do meio ambiente. Finalmente, a hipótese considerada demonstrou que as mudanças na estrutura legislativa nas três esferas de poderes são necessárias, visando à aplicabilidade de responsabilidade legal na esfera nuclear, principalmente no que se refere às entidades administrativas e estatais. / The use and increasingly steady application of consistent nuclear technology in areas related to health, energy, industrial, war, agriculture, among others, means that there is a need for regulation in accordance with the safety standards and international radiological protection . Thus, using concepts from the Constitutional Law, Environmental Law and Labor Law, the focus of this research was to investigate the difficult issue of nuclear competence and environmental responsibility, the impossibility of legislating states, as well as the lack of regulation on radioactive waste. Therefore, it has been updated and revised criteria and methods of constitutional interpretation to solve possible legal antinomies arising from multiple positivation of the federal entities rules that hinder both the assurance and the improvement of radiation protection of workers and the environment. Finally, the working hypothesis has shown that changes in the legislative framework in the three spheres of power is needed in order to applicability of legal liability in the nuclear sphere, especially with regard to administrative and state entities
59

Avaliação do conhecimento e atitudes dos profissionais de saúde de um hospital de ensino sobre proteção radiológica / Assessment of knowledge and attitudes of health professionals from a university hospital about radiation protection

Batista, Vinicius Martins Dias 14 March 2017 (has links)
Submitted by Filipe dos Santos (fsantos@pucsp.br) on 2017-03-27T10:21:54Z No. of bitstreams: 1 Vinicius Martins Dias Batista.pdf: 1543209 bytes, checksum: 0d8e882a87ce71946ea5ad1860282d27 (MD5) / Made available in DSpace on 2017-03-27T10:21:54Z (GMT). No. of bitstreams: 1 Vinicius Martins Dias Batista.pdf: 1543209 bytes, checksum: 0d8e882a87ce71946ea5ad1860282d27 (MD5) Previous issue date: 2017-03-14 / Background: The concept of radioprotection is usually recognized as important among the technical level of health professionals and higher. However, the information on the formal knowledge and its application in practice are scarce. Noticing the discrepancy in radiation protection process in sectors using ionizing radiation, decided to search the knowledge that health professionals have on radiation protection and the need for educational intervention for professionals to work consciously and with adequate protection. Objectives: To assess the knowledge that the health professionals of a university hospital (UH) have about radioprotection, educate staff about the harmful effects of ionizing radiation and application of the ALARA (As Low As Reasonably Achievable) principle in routine work and implement the knowledge of radioprotection through playful learning using teaching materials and easy to understand. Methods: This is an exploratory cross-sectional study with a qualitative analysis of the open questions and the quantitative issues addressed by a semi-structured questionnaire was applied to 59 employees from different sectors of UH to assess the degree of knowledge. From the findings it was prepared a booklet with playful images to be distributed to all employees of the UH. In the internal prevention week of work accidents at the UH it was made by the employees a performance about radioprotection. Results: According to the participants with technical or graduated degree, they did not have training on radiation protection as students or it was insufficient to practice. The work environment, even in a UH, provides little information about radiation protection and the rules which govern it. Much of the respondents (25%) even knowing not observe the radiation protection procedures. In the assessment of formal knowledge on the concept and the usual measures of radioprotection we observed that 1/3 of the participants have good theoretical knowledge, 1/3 have incomplete knowledge and 1/3 is completely unaware of the concept and radioprotection actions. Conclusion: The employees of a UH, even at graduated level, need training on radiation protection, because the training course failed in this respect. We believe the same should happen in other health institutions. The actions aimed at training in radiation protection were very well accepted by employees and their effective translation greater individual and collective protection is being evaluated / Introdução: O conceito de radioproteção é habitualmente reconhecido como importante entre os profissionais de saúde de nível técnico e superior, porém, são escassas as informações sobre o conhecimento formal e sua aplicação na prática. Percebendo a defasagem no processo de proteção radiológica nos setores que utilizam radiação ionizante, resolvi pesquisar o conhecimento que os profissionais da saúde têm sobre proteção radiológica e a necessidade de intervenção educativa para que os profissionais trabalhem de forma consciente e com proteção adequada. Objetivos: Avaliar o conhecimento que os profissionais de saúde de um hospital de ensino (HE) têm sobre radioproteção; conscientizar as equipes sobre os efeitos danosos das radiações ionizantes e aplicação do princípio ALARA (As Low As Reasonably Achievable) na rotina de trabalho e implementar o conhecimento sobre radioproteção através do ensino lúdico utilizando material didático e de fácil compreensão. Métodos: Trata-se de um estudo transversal exploratório com análise qualitativa das questões abertas e quantitativa das questões dirigidas. Foi aplicado um questionário semiestruturado a 59 funcionários dos diferentes setores do HE para avaliar o grau de conhecimento existente. A partir dos achados foi elaborada uma cartilha com imagens lúdicas para ser distribuída a todos os funcionários do HE. Na semana interna de prevenção de acidentes de trabalho do HE foi feita pelos funcionários teatralização sobre a radioproteção. Resultados: Na opinião dos participantes o curso técnico ou superior que fizeram não forneceu formação sobre radioproteção ou esta foi insuficiente para a prática. O ambiente de trabalho, mesmo em um HE, disponibiliza poucas informações sobre radioproteção e as normas que a regem. Boa parte dos entrevistados (25%) mesmo tendo conhecimento não observam as medidas de radioproteção. Na aferição do conhecimento formal sobre o conceito e as medidas habituais de radioproteção observamos que 1/3 dos participantes tem bom conhecimento teórico, 1/3 tem conhecimento incompleto e 1/3 desconhece completamente o conceito e as ações de radioproteção. Conclusão: Os funcionários de um HE, mesmo os de nível superior, têm necessidade de capacitação sobre radioproteção, pois o curso de formação falhou neste aspecto. Acreditamos que o mesmo deve acontecer em outras instituições de saúde. As ações objetivando a capacitação em radioproteção foram muito bem aceitas pelos funcionários e sua tradução efetiva em maior proteção individual e coletiva está sendo avaliada
60

A flexibilização da competência e do processo normativo em relação à segurança e a proteção radiológica / The flexibility of competence and regulatory process regarding safety and radiation protection

Vanessa da Ana 09 December 2016 (has links)
O uso e a aplicação cada vez mais constante da tecnologia nuclear consistente em áreas relacionadas à saúde, energia, industrial, bélica, agrícola, entre outras, faz com que haja a necessidade de uma regulamentação de acordo com os padrões de segurança e proteção radiológica internacionais. Dessa forma, utilizando-se de conceitos provenientes do Direito Constitucional, do Direito Ambiental e do Direito do Trabalho, o enfoque da presente pesquisa foi investigar a difícil questão da competência nuclear e a competência ambiental, a impossibilidade de legislar dos Estados, bem como a falta de regulamentação sobre Rejeitos radioativos. Para tanto, foram atualizados e revisados critérios e métodos de interpretação constitucional para solucionar possíveis antinomias jurídicas advindas de múltipla positivação de normas pelos entes federados que dificultam tanto o asseguramento quanto o aprimoramento da Proteção radiológica do trabalhador e do meio ambiente. Finalmente, a hipótese considerada demonstrou que as mudanças na estrutura legislativa nas três esferas de poderes são necessárias, visando à aplicabilidade de responsabilidade legal na esfera nuclear, principalmente no que se refere às entidades administrativas e estatais. / The use and increasingly steady application of consistent nuclear technology in areas related to health, energy, industrial, war, agriculture, among others, means that there is a need for regulation in accordance with the safety standards and international radiological protection . Thus, using concepts from the Constitutional Law, Environmental Law and Labor Law, the focus of this research was to investigate the difficult issue of nuclear competence and environmental responsibility, the impossibility of legislating states, as well as the lack of regulation on radioactive waste. Therefore, it has been updated and revised criteria and methods of constitutional interpretation to solve possible legal antinomies arising from multiple positivation of the federal entities rules that hinder both the assurance and the improvement of radiation protection of workers and the environment. Finally, the working hypothesis has shown that changes in the legislative framework in the three spheres of power is needed in order to applicability of legal liability in the nuclear sphere, especially with regard to administrative and state entities

Page generated in 0.0613 seconds