• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 444
  • 9
  • 8
  • Tagged with
  • 470
  • 273
  • 124
  • 79
  • 68
  • 60
  • 56
  • 53
  • 51
  • 49
  • 45
  • 44
  • 42
  • 41
  • 41
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
131

Avaliação de um novo protocolo para remoção de retentores metálicos por meio do ultrassom em dentes multirradiculares

Souza, Samir Noronha de 24 February 2014 (has links)
Submitted by Geyciane Santos (geyciane_thamires@hotmail.com) on 2015-06-16T15:47:05Z No. of bitstreams: 1 Dissertação -Samir Noronha de Souza.pdf: 1429754 bytes, checksum: 835f9975774739f2f3c90832d7100d72 (MD5) / Approved for entry into archive by Divisão de Documentação/BC Biblioteca Central (ddbc@ufam.edu.br) on 2015-06-16T18:26:30Z (GMT) No. of bitstreams: 1 Dissertação -Samir Noronha de Souza.pdf: 1429754 bytes, checksum: 835f9975774739f2f3c90832d7100d72 (MD5) / Approved for entry into archive by Divisão de Documentação/BC Biblioteca Central (ddbc@ufam.edu.br) on 2015-06-16T18:27:24Z (GMT) No. of bitstreams: 1 Dissertação -Samir Noronha de Souza.pdf: 1429754 bytes, checksum: 835f9975774739f2f3c90832d7100d72 (MD5) / Made available in DSpace on 2015-06-16T18:27:24Z (GMT). No. of bitstreams: 1 Dissertação -Samir Noronha de Souza.pdf: 1429754 bytes, checksum: 835f9975774739f2f3c90832d7100d72 (MD5) Previous issue date: 2014-02-24 / CAPES - Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / The purpose of this paper is to evaluate in vitro a new protocol for intra-radicular posts removal for multi-radicular teeth by applying ultrasonic vibration. Forty lower molars were endodontically treated in order to receive cast posts and cores, being distributed in 4 groups: GI – control without slot; GII – control with slot; GIII – ultrasound application in core without slot; GIV – ultrasound application in core with slot. After the cast posts fixation using zinc phosphate cement, the ultrasonic vibration was applied in group III for 1 minute, dividing 15 seconds on each surface and in group IV 15 seconds on facial and lingual surface, and 30 seconds inside the slot totaling 1 minute. Thereafter, samples were subjected to tensile test in Universal Assay Machine at the speed of 1mm/min. The maximum tensile strength needed for intra-radicular posts removal was registered in Newton and its data were subjected to statistical analysis ANOVA e Tukey-Kramer. The results presented statistically significant differences between the tested groups (GI – 234,34 N; GII – 201,67 N; GIII – 139,57 N; GIV – 83,23 N), with the smallest average of the tensile strength obtained when ultrasonic vibration on the core slotted applied (p<0,05). It is concluded that the implemantation of a slot in the core and ultrasonic application on all the surfaces and inside the slot caused a reduction of force required for removing cast posts and cores fixed with zinc phosphate in multi-radicular teeth. / Este trabalho visa avaliar in vitro um novo protocolo para remoção de retentores intrarradiculares em dentes multirradiculares aplicando a vibração ultrassônica. Quarenta molares inferiores foram tratados endodonticamente para receber retentores intrarradiculares fundidos, sendo distribuídos em 4 grupos: GI – controle sem fenda; GII – controle com fenda; GIII – aplicação ultrassom em núcleo sem fenda; GIV – aplicação de ultrassom em núcleo com fenda. Após a fixação dos retentores com cimento de fosfato de zinco, a vibração ultrassônica foi realizada no grupo III durante 1 minuto, sendo 15 segundos em cada face e no grupo IV 15 segundos nas faces vestibular e lingual, e 30 segundos dentro da fenda, totalizando 1 minuto. Em seguida, os corpos-de-prova foram submetidos ao teste de tração na Máquina Universal de Ensaio com velocidade de 1 mm/min. A força de tração máxima necessária para a remoção do retentor intrarradicular foi registrada em Newton e os dados foram submetidos à análise estatística ANOVA e Tukey-Kramer. Os resultados mostraram haver diferença estatística significante entre os grupos testados (GI – 234,34 N; GII – 201,67 N; GIII – 139,57 N; GIV – 83,23 N), sendo a menor média da força de tração obtida quando se aplicou vibração ultrassônica sobre o núcleo com fenda (p<0,05). Conclui-se que a realização de uma fenda no núcleo e a aplicação ultrassônica em todas as faces e dentro da fenda promoveu a redução da força necessária para a remoção de retentores intrarradiculares metálicos fixados com fosfato de zinco em dentes multirradiculares.
132

Caracterização do cromo presente no lodo de galvanoplastia: avaliação técnica e econômica de processos de remoção / Characteristics of chromium from electroplating sludge: technical and economic evaluation of removal processes

Lucas Campaner Alves 05 February 2016 (has links)
O lodo gerado em processos de galvanoplastia é classificado pela ABNT NBR 10.004/04 como perigoso (classe I). Na literatura encontram-se poucos estudos referentes à recuperação do cromo presente no lodo gerado em sistemas de tratamento de efluentes de indústrias de galvanoplastia. Neste sentido, o presente estudo avaliou a remoção do cromo presente no lodo de galvanoplastia por meio de dois processos, visando avaliar à eficiência técnica e a viabilidade econômica de ambos. O Processo 1 consistiu na remoção do cálcio utilizando o ácido cítrico, seguida de lixiviação ácida. Na etapa de oxidação, variou-se a temperatura em 40ºC, 60ºC e 80ºC e no tempo de 30, 60 e 90 minutos, tendo em vista que a eficiência do processo de oxidação depende da temperatura e tempo. Nesta etapa do processo as concentrações de peroxido de hidrogênio (H2O2) utilizadas foram de 1,50, 3,00 e 4,50 mol.L-1. O Processo 2 realizou a oxidação do cromo sem efetuar as etapas de extração do cálcio e a lixiviação ácida. A oxidação do cromo ocorreu pelo mesmo método apresentado no Processo 1. A caracterização elementar da amostra determinou que o principal elemento constituinte do lodo é o cálcio (20,05% em massa), e que dentre os metais pesados destacam-se o cromo e o níquel (6,52% e 4,33% em massa, respectivamente). A maior eficiência de remoção do cálcio foi obtida na razão mássica de 8,00 (ácido cítrico/hidróxido de cálcio), com 51,76% em massa, seguida pela razão mássica de 5,50 com 36,75% em massa e 2,50 com 24,83% em massa. O melhor resultado de oxidação do cromo no Processo 1 foi obtido com tempo de 30 minutos, temperatura de 60ºC e concentração de peroxido de hidrogênio de 3,00 mol.L-1, com eficiência de 41,09% em massa. No Processo 2, obteve-se a remoção de 37,96% em massa de cromo a temperatura de 80ºC, por uma hora e 3,00 mol.L-1 de peróxido de hidrogênio. Avaliando os custos para remoção do cromo dos dois processos, determinou-se que o Processo 1 foi mais oneroso que o 2, porém ambos não apresentaram viabilidade econômica para aplicação em escala industrial. Nos dois processos efetuou-se a oxidação do cromo presente no lodo de galvanoplastia, permitindo a sua remoção parcial neste resíduo. Com isso obtiveram-se ganhos ambientais, pela diminuição deste elemento no resíduo de galvanoplastia, que na maioria das vezes é disposto em aterros classe I, gerando um passivo ambiental. / The sludge generated in electroplating processes is classified by NBR 10.004/04 as a hazardous material (class I). In the literature, few studies report the recovery of chromium present in the electroplating sludge generated in the industries. In this sense, the present study conducted the removal of chromium in the electroplating sludge through two different processes, aiming to evaluate their efficiency and economic viability. The first process removed calcium through the use of citric acid being performed by varying the ratio of citric acid/calcium hydroxide (2.5, 5.5 and 8.0). Then, were performed the leaching of the samples. According to the literature, the efficiency of the oxidation process varies depending on the reaction temperature, time and concentration of hydrogen peroxide. For this reason, samples were heated to a temperature ranging from 40°C, 60°C and 80°C. Also, were conducted variations in the concentrations of hydrogen peroxide (1.5, 3.0 and 4.5 mol.L-1) and reaction time (30, 60 and 90 minutes). The second Process consisted in the chrome recovery by using the galvanic sludge without removal of the calcium and acid leaching. The chrome oxidation occurred by the same method shown in Process 1. Elemental characterization of the samples determined that the primary sludge constituent was calcium (20.05% by weight), and in terms of heavy metals, the chromium and the nickel (6.52% and 4.33% by mass, respectively). Most of calcium removal efficiency was obtained at a rate of 8 with 51.76% by mass, then the ratio of 5.50 to 36.75% by mass and 2.50 to 24.83% by mass. The best oxidation result of chromium in Process 1 was obtained using a time of 30 minutes, 60°C and hydrogen peroxide concentration of 3 mol.l-1, with 41.09 wt% efficiency. In Process 2 was obtained the removal of 37.96% by mass of chromium temperature of 80°C, for one hour and 3,00 mol.l-1 of hydrogen peroxide. Evaluating the costs for chrome removal of the two processes was determined that the Process 1 was more costly than 2, but both showed no economic feasibility for implementation on an industrial scale. However, in both cases occurred the oxidation of chromium present in the electroplating sludge, allowing its removal from the residue. Thus, environmental gains have been achieved by the reduction of this element in electroplating waste, which mostly is intended for landfill class I, generating an environmental liability.
133

Biofiltro submerso modificado para pós-tratamento do efluente de lagoas de estabilização / Modified submerged biofilter for post treatment of the effluent of stabilization lagoons

Gerson Pavanelli 27 August 2014 (has links)
Esta pesquisa propôs o desenvolvimento de um sistema de biofiltros submersos, modificados com base na configuração de filtros de pedra, visando o pós-tratamento do efluente de lagoas de estabilização, inicialmente para a remoção de algas. A modificação consiste na variação das alturas da camada filtrante e na colocação de tampa na superfície do BS, evitando o acesso da luz. O esgoto tratado captado na lagoa de maturação foi feito em duas profundidades &#8211; a 60 cm de profundidade da superfície da lagoa (denominada zona superficial) e a 180 cm de profundidade da superfície da lagoa (denominada zona intermediárias). O experimento foi composto por 8 BS sendo 4 BS alimentados pelo esgoto captado na zona superficial (60 cm) e outros 4 BS alimentados pela esgoto captado na zona intermediária (180 cm). Foi utilizado, como recheio dos biofiltros submersos, pedra brita nº 3, nas seguintes alturas de camada filtrante: 50 cm, 100 cm, 150 cm e 200 cm, tendo por objetivo avaliar a influência deste fator sobre a eficiência de remoção de algas mediante análise de Clorofila a, e outras 16 variáveis de qualidade associadas neste estudo. Concluiu-se que a extração a partir da zona superficial da lagoa de maturação, e uma profundidade de leito entre 150 cm e 200 cm, foram os parâmetros operacionais que levaram a um melhor desempenho global dos biofiltros submersos modificados, e mais especificamente quanto às seguintes variáveis: Clorofila a, DQO (Demanda Química de Oxigênio), DBO (Demanda Bioquímica de Oxigênio) e sólidos totais. / This research proposed the development of a submerged bio filters system, modified based in rock filters configuration, aiming the post treatment of the effluent of stabilization lagoons, for algae removal first. The modification consists invariance of the heights of the filter layer and the cover placed on the surface of the BS, preventing access of light. The treated sewage captured in the maturation lagoon was made at two depths &#8211; at 60cm depth of the lagoon surface (called superficial zone) and at 180cm depth of the lagoon surface (called intermediary zone). The experiment consisted of 8 BS, with 4 BS being fed by sewage captured in the superficial zone (60 cm) and other 4 BS fed by sewage captured in the intermediary zone (180 cm). It was used, as a stuff of submerged biofilters, rock number three, at the following heights of filtering layers: 50 cm, 100 cm, 150 cm e 200 cm, aiming to evaluate the influence of this factor over algae removal efficiency towards chlorophyll a, and other 16 quality variables associated in this study. It was concluded that the collecting from superficial zone of the maturation lagoon, and a layer depth between 150 cm e 200 cm, were the operational parameters that lead to a better overall performance of modified submerged biofilters, and more particularly to the following variables: Chlorophyll a, COD (Chemical Oxygen Demand), BOD (Biochemical Oxygen Demand) and total solids.
134

Remoção da biomassa algal e determinação da concentração de microcistina pelo Método ELISA em ensaios de coagulação, sedimentação, filtração e adsorção / Removal of algal biomass and determinacy of microcystins concentration through ELISA method in tests of coagulation, sedimentation, filtration and adsorption

Luciana Pallone Hespanholo Ferreira 17 September 2004 (has links)
Nessa pesquisa são relatados os resultados da determinação das concentrações de microcistina e de biomassa algal após as várias etapas de tratamento de amostras de água coletadas junto ao reservatório de Barra Bonita-SP visando obtenção de água potável. O tratamento foi realizado em escala de laboratório com e sem aplicação de carvão ativado em pó (CAP) e as etapas foram: coagulação com aplicação de cloreto férrico, sedimentação, filtração em papel de filtro. Foi possível observar que a pré-clarificação desse tipo de água por coagulação seguida de sedimentação requereu dosagens relativamente elevadas de cloreto férrico (80 mg/L), tendo sido verificada eficiência muito baixa de remoção de microcistina nas etapas de tratamento por sedimentação seguida de filtração, quando não foi aplicado CAP. Apenas com a aplicação de CAP a microcistina foi reduzida à níveis que atendessem os padrões de potabilidade previstos na Portaria 518/04 (concentração menor que 1 &#956g/L). A determinação de microcistina pelo método que utiliza Imunoadsorventes Ligados à Enzima (ELISA) mostrou-se uma ferramenta útil e confiável para detectar e quantificar essa toxina, embora ainda apresente custo relativamente elevado. / This report presents the results of the quantification of microcystins and algae biomass concentrations after treatment of water samples taken from the Barra Bonita reservoir, for production of potable water. Bench-scale tests were carried out with and without powdered activated carbon (PAC) and the treatment processes used were: coagulation with ferric chloride (FeCl3), sedimentation and filtration with paper filter. It was determined that pre-clarification followed by sedimentation required substantial dosages of ferric chloride (80 mg/L). The removal of microcystins using sedimentation followed by filtration was ineffective without PAC. The use of PAC is required to produce water that meets current potability standards for microcystins removal as specified in Decree 518/04 (concentration less than 1 &#956g/L). Analysis of microcystins using the Enzime-Linked Immunosorbent Assay Method (ELISA) has proven to be an effective and reliable procedure to detect and quantify this toxin, although relatively expensive.
135

Influência do tamanho molecular aparente das substâncias húmicas aquáticas na eficiência da coagulação com sulfato de alumínio e cloreto férrico / Influence of apparent molecular size from aquatic humic substances in the coagulation efficiency with aluminium sulfate and ferric chloride

Sloboda, Eliane 01 November 2007 (has links)
Existem muitos mananciais usados como fonte de abastecimento de água que apresentam cor verdadeira relativamente alta, devido à presença de substâncias húmicas (SH). Muitas estações de tratamento de água (ETA) apresentam problemas no processo de coagulação decorrentes da presença das SH. Com isso é necessário o uso de pré-oxidantes para reduzir a cor verdadeira da água. Quando emprega-se o cloro como oxidante ocorre a formação de subprodutos halogenados, que são prejudiciais a saúde humana. Para este estudo coletou-se água no Rio Itapanhaú - Bertioga/SP, a qual apresentou cor verdadeira na ordem de 400 uH. Para a extração das SHA empregou-se a resina XAD 8. Os extratos de SHA foram filtrados em membrana com poros de 0,45 µm e após utilizou-se a técnica de ultrafiltração (UF) para o fracionamento do material húmico em diferentes tamanhos moleculares aparente. As frações empregadas na caracterização foram: F1: menor que 0,45 µm, F2: entre 100 kDa e 0,45 µm, F3: entre 30 e 100 kDa, F4: entre 10 e 30 kDa, F5: entre 5 e 10 kDa. As frações foram caracterizadas por meio das técnicas de análise elementar, espectroscopia de ultravioleta/visível, infravermelho e ressonância magnética nuclear de 13C (RMN de 13C). Os resultados mostraram que as frações de menor tamanho molecular aparente (F3, F4 e F5) possuem maior conteúdo de carbonos alifáticos do que carbonos aromáticos e uma porcentagem relativamente alta de oxigênios ligados a grupamentos alquílicos e a ácidos carboxílicos. As frações de maior tamanho molecular aparente (F1 e F2) apresentaram maior grau de condensação de grupamentos aromáticos. No caso dos espectros de RMN de 13C, não foi possível verificar diferenças significativas nas diferentes frações de SHA. Verificou-se picos mais intensos na região de grupos carboxil e alifáticos e menos intenso na região dos aromáticos. Isso indica que nas SHA há maior conteúdo de grupamentos oxigenados e carbonos alifáticos. As amostras de água de estudo foram preparadas com água de poço artesiano e com as frações de diferentes tamanhos moleculares aparentes das SHA (F1: menor que 0,45 µm, F2: entre 100 kDa e 0,45 µm e F3: entre 30 e 100 kDa e F4\': menor que 30 kDa) com cor verdadeira aproximadamente de 100 uH e turbidez em torno de 0,5 uT. Para avaliar a influência dos diferentes tamanhos moleculares aparentes das SHA na eficiência da coagulação foram feitos ensaios em jartest empregando filtração direta descendente. Os coagulantes empregados neste estudo foram, o sulfato de alumínio e cloreto férrico, ambos como produto comercial líquido. Os diagramas de coagulação evidenciaram a influência do tamanho molecular aparente das SHA no processo de coagulação, quando empregou-se os coagulantes sulfato de alumínio e cloreto férrico. Para as águas de estudo preparadas com as frações de menor tamanho molecular aparente, foi necessário maior dosagem de coagulante para se obter remoção da cor aparente da água e mesmo assim, a remoção foi menor. A fração de menor tamanho molecular aparente (F4\') apresenta maior porcentagem de ácidos fúlvicos, e estes apresentam maior quantidade de grupos com carga negativa. Por isso, há necessidade de maior dosagem de coagulante para que ocorra uma eficiente remoção de cor aparente. / Water sources used to supply the public water system frequently have a relatively high true color intensity due to dissolved aquatic humic substances (AHS). In this study, water samples were collected from the Itapanhaú River (Bertioga, SP, Brazil), which exhibited a true color intensity in the order of 300 Hanzen units. XAD-8 resin was used to extract AHS. The AHS extract was filtered through a membrane with 0.45 µm pores, giving fraction F1, and this was separated by ultrafiltration into 4 apparent molecular size fractions of humic material: F2 from 100 kDa to 0.45 µm, F3 from 30 to 100 kDa, F4 from 10 to 30 kDa and F5 from 5 to 10 kDa. The fractions were characterized by elemental analysis and UV/Vis, infra-red (IR) and carbon 13 nuclear magnetic resonance (13C-NMR) spectroscopy. In general, the results showed that the smaller molecular size fractions (F3, F4 and F5) had a higher proportion of aliphatic than aromatic carbon atoms and a relatively high percentage of oxygen atoms bonded to alkyl groups and in carboxylic acids. Conversely, the apparently larger molecules (fractions F1 and F2) showed a higher content of aromatic groups. In the case of the 13C-NMR spectra, no significant differences could be detected among the fractions. There were stronger peaks in the carboxyl group and aliphatic carbon region and weaker peaks in the aromatic region, indicating that in the AHS as a whole, there is a greater content of oxygenated groups and aliphatic carbon atoms. Water from an artesian well was used to prepare experimental samples of the following molecular size fractions of AHS: F1 < 0.45µm, F2 from 100 kDa to 0.45 µm and F3: from 30 kDa to 100 kDa and F4\': < 30 kDa, with true color intensity around 100 Hazen units and turbidity around 5.0 NTU. To assess the influence of the apparent molecular size on the efficiency of coagulation, jar test were carried out, using direct filtration. The coagulants employed were aluminum sulfate and ferric chloride. The coagulation diagrams obtained with these products revealed the effects of the molecular size of the AHS on the coagulation process. For the experimental samples, fractions F3 e F4 \', a greater dose of coagulant was needed to remove the apparent water color around 5.0 Hanzen units and, even then, the amount removed was smaller. F4\' also had a higher proportion of fulvic acids, which exhibited a larger number of negatively-charged groups. For these reasons, a high dose of coagulant is necessary to achieve an efficient removal of apparent color.
136

Cryogel composites for cadmium removal : evaluating combinations and adsorption by molecularly imprinted polymers

Duarte, Mariana Sofia Nogueira January 2012 (has links)
Tese de mestrado integrado. Engenharia Química. Faculdade de Engenharia. Universidade do Porto. 2012
137

Estudo da aplicação da extracção supercrítica à remoção de pesticidas de solos contaminados

Augusto, Teresa Cândida Barbosa Castelo Grande Edmond January 2004 (has links)
Dissertação apresentada para obtenção do grau de Mestre em Engenharia do Ambiente,(área de especialização de Tratamento de Águas e Águas Residuais), na Faculdade de Engenharia da Universidade do Porto, sob a orientação do Doutor Domingos Barbosa
138

Carbon dioxide removal from anaesthetic gas circuits using absorbent membrane contactors

Portugal, Ana Filipa Fernandes Vaz January 2009 (has links)
Tese de doutoramento. Engenharia Química e Biológica. Faculdade de Engenharia. Universidade do Porto. 2009
139

Remoção de íons Zn2+ por adsorção em carvão ativado em batelada e processo contínuo

Santos, Liliana Dutra dos January 2014 (has links)
O zinco é um dos metais mais utilizados nos processos de tratamento de superfícies. Os efluentes contaminados com zinco, gerados nestes processos, trazem preocupação devido ao grande volume, elevada toxicidade, acumulação e persistência. O presente estudo avaliou a remoção de íons zinco de soluções aquosas, por adsorção em carvão ativado comercial, através de experimentos em batelada e em escala piloto. Ensaios em batelada objetivaram estudar a influência dos parâmetros de processo pH, tempo de contato e concentração de sólido adsorvente na remoção de íons Zn2+ a partir de uma solução com concentração inicial de 10 mg.L-1. A partir das melhores condições encontradas, a isoterma de equilíbrio do sistema foi construída e o ajuste dos dados experimentais aos modelos não lineares de Langmuir, Freundlich, Redlich-Peterson e Sips foi verificado. Ensaios em planta piloto foram realizados a fim de identificar a curva de ruptura do sistema. No processo de adsorção contínuo em leito fixo, foram avaliadas diferentes condições operacionais, variando-se a vazão de alimentação (15 e 20 mL.min-1) e a massa de adsorvente utilizada como recheio do leito (10, 13, 20 e 40 g). Os resultados apontaram como parâmetros ótimos de adsorção: pH igual a 6, tempo de contato de 30 min e concentração de sólido adsorvente de 20 g.L-1. O modelo de Sips apresentou o melhor ajuste dentre os modelos matemáticos estudados. O experimento realizado em planta piloto utilizando-se uma vazão de 15 mL.min-1 e massa de sólido sorvente de 40 g, obteve os melhores resultados dentre as condições analisadas, apresentando tempo de ruptura e exaustão do leito aos 5 e 90 min, respectivamente. / Zinc is one of the most used metals in surface treatment processes. The effluents contaminated with zinc, generated in these processes, bring concern due to the large volumes, high toxicity, persistence and accumulation. This study evaluated the removal of zinc ions from aqueous solutions, through adsorption by commercial activated carbon, using continuous (pilot plant) and bench scale. The batch experiments studied the influence of pH, contact time and adsorbent concentration in the removal of Zn 2+ ions from a solution with initial concentration of 10 mg.L-1. After achieving the best process parameters, the system’s equilibrium isotherm was constructed, and the fit of experimental data to the nonlinear Langmuir, Freundlich, Redlich-Peterson and Sips models was verified. Pilot plant tests were carried out in order to identify the system’s breakthrough curve. In the continuous fixed bed adsorption process, different operating conditions were evaluated by varying the feed flow (15 and 20 mL.min-1) and the mass of adsorbent material used as filling (10, 13, 20 and 40 g). The results showed as the optimum parameters for adsorption: pH 6, contact time of 30 min and adsorbent concentration of 20 g.L-1. The Sips model presented the best fit among the mathematical models studied. The experiment conducted in a pilot plant, using a flow rate of 15 mL.min-1 and solid adsorbent mass of 40 g, had the best results among the examined conditions, with breakthrough and exhaust times of 5 and 90 min, respectively.
140

Aplicação de micelas reversas na remoção de corantes têxteis catiônicos

Ueda, Ana Cláudia January 2006 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico. Programa de Pós-Graduação em Engenharia Química / Made available in DSpace on 2012-10-22T19:40:31Z (GMT). No. of bitstreams: 1 225998.pdf: 1923818 bytes, checksum: 7b977346b3b9f79be8e47a40560e560f (MD5) / A remoção de corantes de águas residuárias têxteis tem sido um assunto de grande interesse nas últimas décadas. Hoje em dia, este tema tem tido destaque principalmente devido às novas normas ambientais à cobrança pela utilização da água. Os corantes têxteis modernos possuem alto grau de estabilidade química e fotocatalítica, de forma a manter sua cor por mais tempo. Devido à característica recalcitrante dos corantes, uma combinação de tratamentos é necessária para a purificação do efluente. Os mais estudados são tratamentos por: membranas, adsorção, oxidação avançada e físico-químicos, como coagulação/floculação e microemulsões. Os surfactantes são moléculas compostas por uma parte hidrofílica, denominada cabeça e uma cadeia linear carbônica apolar (hidrofóbica), denominada cauda. As micelas são agregados de monômeros de surfactantes, são estáveis termodinamicamente, isotrópicas e de baixa viscosidade. No caso das micelas reversas, sua formação se dá em solventes orgânicos contendo ínfimas quantidades de água, na qual a cabeça (polar) fica voltada para o pequeno "poço aquoso" em seu interior e a cauda (apolar) fica voltada para fora, na fase orgânica, "protegendo" a parte hidrofílica. No presente trabalho foi investigada a aplicação de micelas reversas na remoção de corantes têxteis catiônicos, através da variação das concentrações de corante e de surfactante, da temperatura, do efeito de sal e do volume de fase orgânica no sistema. Este método permite, além da remoção do corante, o seu posterior reaproveitamento através da recuperação da fase orgânica, bem como a reutilização da própria fase orgânica. Foi estudada a remoção dos corantes catiônicos (CI Basic Blue 41, CI Basic Red 46 e CI Basic Yellow 28) com o surfactante aniônico (Dodecil sulfato de sódio ou Lauril Sulfato de Sódio - SDS). Como solvente orgânico foi utilizado o Álcool Isoamílico e o sal foi o Cloreto de Potássio. A concentração de corante presente na fase aquosa foi determinada através de análise espectrofotométrica e os resultados foram expressos pela porcentagem de remoção do corante da fase aquosa. Os resultados obtidos experimentalmente foram analisados estatisticamente através do Método da Superfície de Resposta. Os ensaios experimentais forneceram resultados de remoção máxima superiores a 99% para os três corantes. A análise estatística dos resultados experimentais forneceu como principais fatores significativos a porcentagem de fase orgânica presente no sistema e a concentração de surfactante. Esta análise também forneceu um modelo estatístico-matemático que representa o processo, cujos coeficientes de determinação foram de 85, 70 e 87% para os corantes CI Basic Yellow 28, CI Basic Blue 41 e CI Basic Red 46, respectivamente.

Page generated in 0.0298 seconds