• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 444
  • 9
  • 8
  • Tagged with
  • 470
  • 273
  • 124
  • 79
  • 68
  • 60
  • 56
  • 53
  • 51
  • 49
  • 45
  • 44
  • 42
  • 41
  • 41
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
101

Remoção de \'CD POT.2+\' e \'CU POT.2+\' de águas residuárias utilizando biorreator anaeróbio contínuo de leito fixo ordenado / Wastewater \'CD POT.2+\' and \'CU POT.2+\' removal using a continuous Anaerobic Bioreactor with Fixed-Structured Bed

Mockaitis, Gustavo 21 March 2011 (has links)
O presente trabalho apresenta o biorreator anaeróbio contínuo de leito fixo ordenado como alternativa ao tratamento de efluentes contendo os íons \'CU POT.2+\' e \'CD POT.2+\', sendo que cada metal foi estudado isoladamente. O biorreator operou sempre com um tempo de detenção hidráulica de 12 à 15 horas, com uma água residuária sintética simulando o esgoto sanitário, na concentração de 500 mg \'0 IND.2\'/L (em termos de DQO), a uma temperatura de 30°C. Durante a fase na qual o biorreator operou com água residuária em condições metanogênicas o biorreator foi alimentado, em condições distintas, com concentrações crescentes de \'CU POT.2+\' e \'CD POT.2+\'. O acúmulo dos metais na matriz de imobilização levou ao bioreator apresentar instabilidade na operação, sendo determinadas as concentrações críticas para o \'CU POT.2+\' (50,8 mg \'CU POT.2+\'/L) e para o \'CD POT.2+\' (29,8 mg \'CD POT.2+\'/L). Durante a operação nas condições metanogênicas foi observado o efeito tóxico pela diminuição na eficiência de remoção de matéria orgânica, mas sem perder a estabilidade operacional até que as concentrações críticas foram atingidas. A partir dos valores das concentrações críticas, o biorreator foi operado em condições sulfetogênicas em duas relações DQO/[\'SO IND.4\'POT.2-\'] distintas (0,68 e 1,99 para o uma concentração média de 36 mg \'CU POT.2+\'/L; e 0,69 e 8,02 para uma concentração média de 27 mg \'CD POT.2+\'/L). Nas operações em condições sulfetogênicas, o biorreator operou de maneira estável, no entanto, não foi capaz de remover todo o metal alimentado. / This work presents the anaerobic continuous bioreactor with fixed-structured bed as a viable configuration of treatment of wastewater containing \'CU POT.2+\' and \'CD POT.2+\' ions. Each metallic ion were studied separately. The bioreactor was operated with 12 to 15 hours of hydraulic retention time, with a synthetic wastewater simulating domestic sewage (500 mg \'0 IND.2\'/L, in COD terms), at 30°C. In methanogenic conditions, the bioreactor was fed with crescent amount of \'CU POT.2+\' and \'CD POT.2+\'. The metal accumulation in the irnrnobilization matrix caused instability on bioreactor when achieving the critical concentrations for \'CU POT.2+\' (50,8 mg \'CU POT.2+\'/L) and for \'CD POT.2+\' (29,8 mg \'CD POT.2+\'/L). Also it was observed that this crescent metal concentration affected the efficiency of bioreactor in removing organic matter, although without operational instability until the system reach these critical metal concentrations. The bioreactor was operated in sulfidogenic conditions fed with a wastewater containing \'CU POT.2+\' and \'CD POT.2+\' at critical concentrations considering two different COD/[\'SO IND.4\'POT.2-\'] (0,68 and 1,99 for a mean influent \'CU POT.2+\' concentration of 36 mg \'CU POT.2+\'/L; and 0,69 and 8,02 para for a mean influent \'CD POT.2+\' concentration of 27 mg \'CD POT.2+\'/L). During the sulfidogenic conditions operations the bioreactor operated showing stability, however the system was not able to achieve the maximum efficiency in metal removal.
102

Avaliação de diferentes tempos de detenção hidráulica na remoção de nutrientes em sistema alagado construído

Stopa, Juliana Martins January 2018 (has links)
Orientadora: Profª. Drª. Lúcia Helena Gomes Coelho / Coorientadora. Profª. Drª. Roseli Frederigi Benassi / Dissertação (mestrado) - Universidade Federal do ABC, Programa de Pós-Graduação em Ciência e Tecnologia Ambiental, Santo André, 2018. / De acordo com a Organização Mundial da Saúde (OMS), a água potável segura e o saneamento adequado são fundamentais para a redução da pobreza e para o desenvolvimento sustentável. Entretanto, o aumento da poluição ambiental, o uso excessivo da água sem gerenciamento e a aceleração da eutrofização de corpos hídricos ao longo dos anos tem contribuído para maiores danos à saúde humana e para o desequilíbrio ecossistêmico. Pensando nesse cenário, faz-se necessário desenvolver soluções eficazes e econômicas para o tratamento de efluentes. No presente estudo, foi avaliado um sistema piloto de alagado construído (SAC) com plantas emergentes (Eleocharis sp.) para o pós-tratamento de esgoto sanitário proveniente de uma estação de tratamento de esgoto no município de Arujá - SP. O sistema foi monitorado em duas etapas, sendo a primeira para avaliar o sistema plantado frente ao sistema controle (não plantado) e a segunda, para avaliar o desempenho dos SACs plantados em tempos de detenção hidráulica (TDHs) diferentes, de 2, 4 e 6 dias. Objetivou-se, principalmente, avaliar a eficiência de remoção de nutrientes (N e P), sob elevada condição de oxigenação, em diferentes TDHs e também frente ao SAC controle. O SAC plantado, em geral, obteve remoções superiores em relação ao SAC controle, evidenciando a influência positiva das plantas no sistema. Em relação à etapa II, o SAC operado com TDH = 6 dias foi o que obteve os melhores resultados, com remoções médias de 36,1 % de nitrogênio total, 59,6 % de cor aparente, 62,9 % de turbidez e 78,4 % de Carbono Orgânico Total (COT). Não foi observada influência significativa do TDH na remoção de fósforo total, embora o SAC com maior TDH tenha atingido mais de 74,0 % de remoção em determinado momento. Destaca-se ainda que os níveis de oxigênio dissolvido não foram limitantes para o processo de nitrificação nos SACs, no entanto, podem ter interferido na desnitrificação dos mesmos. Conclui-se, portanto, que o tratamento terciário de efluentes por sistema de alagado construído é viável para remoção de nutrientes, embora parâmetros como oxigênio dissolvido, TDH, manejo das macrófitas e manutenção do substrato devam ser otimizados para melhor desempenho do sistema. / According to the World Health Organization (WHO), safe drinking water and adequate sanitation are the key to poverty reduction and sustainable development. However, the increase of the pollution, extensive use of water without previous planning, and the accelerated eutrophication of water bodies over the years have contributed to further damage to human health and ecosystem imbalance. In this context, it is essential the development and implementation of wastewater treatment systems. In the present study, constructed wetland system (CWS) with emergent plants (Eleocharis sp.) was evaluated for post-treatment of effluent from a wastewater treatment plant in the city of Arujá - SP. The system was monitored in two stages, the first was to evaluate between the system planted and not planted (control system ) and the second phase was made to evaluate the performance of the CWS at different hydraulic retention times (HRT) of 2, 4 and 6 days. The main objective was to evaluate the efficiency of nutrient removal (N and P) under high oxygenation condition in different HRT and also in relation to the control CWS. The planted CWS, in general, obtained superior removals in relation to the control CWS, evidencing the positive influence of the plants in the system. In relation to stage II, the CWS operated with HRT = 6 days was the one that obtained the best results, with mean removals of 36.1 % of total nitrogen, 59.6 % of apparent color, 62.9 % of turbidity and 78.4 % Total Organic Carbon (TOC). No significant influence of HRT was observed in the removal of total phosphorus, although the CWS with greater HRT reached more than 74.0 % of removal at any given moment. It is also worth noting that dissolved oxygen levels were not limiting for the nitrification process in the CWS, however, they may have interfered in the denitrification of the system. It is concluded, therefore, that tertiary effluent treatment by constructed wetland system is feasible for nutrient removal, although parameters such as dissolved oxygen, HRT, macrophyte management and substrate maintenance should be optimized for better system performance.
103

Remoção de \'CD POT.2+\' e \'CU POT.2+\' de águas residuárias utilizando biorreator anaeróbio contínuo de leito fixo ordenado / Wastewater \'CD POT.2+\' and \'CU POT.2+\' removal using a continuous Anaerobic Bioreactor with Fixed-Structured Bed

Gustavo Mockaitis 21 March 2011 (has links)
O presente trabalho apresenta o biorreator anaeróbio contínuo de leito fixo ordenado como alternativa ao tratamento de efluentes contendo os íons \'CU POT.2+\' e \'CD POT.2+\', sendo que cada metal foi estudado isoladamente. O biorreator operou sempre com um tempo de detenção hidráulica de 12 à 15 horas, com uma água residuária sintética simulando o esgoto sanitário, na concentração de 500 mg \'0 IND.2\'/L (em termos de DQO), a uma temperatura de 30°C. Durante a fase na qual o biorreator operou com água residuária em condições metanogênicas o biorreator foi alimentado, em condições distintas, com concentrações crescentes de \'CU POT.2+\' e \'CD POT.2+\'. O acúmulo dos metais na matriz de imobilização levou ao bioreator apresentar instabilidade na operação, sendo determinadas as concentrações críticas para o \'CU POT.2+\' (50,8 mg \'CU POT.2+\'/L) e para o \'CD POT.2+\' (29,8 mg \'CD POT.2+\'/L). Durante a operação nas condições metanogênicas foi observado o efeito tóxico pela diminuição na eficiência de remoção de matéria orgânica, mas sem perder a estabilidade operacional até que as concentrações críticas foram atingidas. A partir dos valores das concentrações críticas, o biorreator foi operado em condições sulfetogênicas em duas relações DQO/[\'SO IND.4\'POT.2-\'] distintas (0,68 e 1,99 para o uma concentração média de 36 mg \'CU POT.2+\'/L; e 0,69 e 8,02 para uma concentração média de 27 mg \'CD POT.2+\'/L). Nas operações em condições sulfetogênicas, o biorreator operou de maneira estável, no entanto, não foi capaz de remover todo o metal alimentado. / This work presents the anaerobic continuous bioreactor with fixed-structured bed as a viable configuration of treatment of wastewater containing \'CU POT.2+\' and \'CD POT.2+\' ions. Each metallic ion were studied separately. The bioreactor was operated with 12 to 15 hours of hydraulic retention time, with a synthetic wastewater simulating domestic sewage (500 mg \'0 IND.2\'/L, in COD terms), at 30°C. In methanogenic conditions, the bioreactor was fed with crescent amount of \'CU POT.2+\' and \'CD POT.2+\'. The metal accumulation in the irnrnobilization matrix caused instability on bioreactor when achieving the critical concentrations for \'CU POT.2+\' (50,8 mg \'CU POT.2+\'/L) and for \'CD POT.2+\' (29,8 mg \'CD POT.2+\'/L). Also it was observed that this crescent metal concentration affected the efficiency of bioreactor in removing organic matter, although without operational instability until the system reach these critical metal concentrations. The bioreactor was operated in sulfidogenic conditions fed with a wastewater containing \'CU POT.2+\' and \'CD POT.2+\' at critical concentrations considering two different COD/[\'SO IND.4\'POT.2-\'] (0,68 and 1,99 for a mean influent \'CU POT.2+\' concentration of 36 mg \'CU POT.2+\'/L; and 0,69 and 8,02 para for a mean influent \'CD POT.2+\' concentration of 27 mg \'CD POT.2+\'/L). During the sulfidogenic conditions operations the bioreactor operated showing stability, however the system was not able to achieve the maximum efficiency in metal removal.
104

Estudo da tratabilidade de efluente de reator anaeróbio e lixiviado de aterro sanitário utilizando o processo de lodos ativados / Treatability of the anaerobic effluent and landfill leachate using activated sludge process

Ludimila Turetta 14 September 2011 (has links)
Embora em alguns países como os europeus, o aterro sanitário como forma de disposição final de Resíduos Sólidos venha perdendo espaço, entre nós essa técnica é ainda largamente empregada. O lixiviado gerado nos aterros sanitários apresenta grande potencial poluidor, devido à presença de matéria orgânica, rica em substâncias húmicas e matéria inorgânica, representada especialmente pelos cloretos, nitrogênio amoniacal, entre outras substâncias. O presente trabalho visou, em linhas gerais, avaliar três proporções de mistura de lixiviado/efluente anaeróbio e as influências sobre o processo aeróbio (lodos ativados) em escala de bancada. Nessa pesquisa foram realizados ensaios de tratabilidade utilizando as proporções de 0% (controle), 2,5%, 10% e 20 % de lixiviado em relação ao efluente anaeróbio em diferentes condições experimentais. Os resultados mostraram que as proporções de 10% e 20% de lixiviado nas condições experimentais foram prejudiciais ao sistema aeróbio de tratamento. Foram obtidos os melhores resultados em termos de eficiência de remoção de matéria orgânica e nitrogênio amoniacal no reator alimentado com a proporção de 2,5% de lixiviado bruto, alcançando eficiência de remoção de DQO e nitrogênio amoniacal total (NAT) de 57% e 100%, respectivamente. / The use of landfill as a disposal of solid waste has been avoided in some countries, especially in Europe. Nevertheless this technique is still widely used in Brazil. Leachate generated in landfills has great potential as pollutant due to presence of organic matter, humic substances in high concentrations and inorganic matter such as chlorides and ammonia nitrogen. This study aims to broadly assess effects of three levels of mixing of leachate/anaerobic effluent on aerobic process (activated sludge) in bench scale. Treatability tests were performed using proportions of 0% (control), 2.5%, 10% and 20% leachate added to anaerobic effluent under different experimental conditions. Results showed that proportions of 10% and 20% of leached were unfavorable to aerobic system treatment. The higher removal efficiency of organic matter and ammonia nitrogen was obtained in reactor fed with 2.5% of leachate (removal efficiency of COD and total ammonia nitrogen (TAN) were 57% and 100%, respectively).
105

Reator com leito de biomassa aderida aerado parcialmente aplicado ao tratamento de esgoto sanitário / Partially aerated attached biomass bed reactor applied to treatment sanitary sewage treatment

Aurélia de Oliveira Almeida 23 April 2010 (has links)
Este trabalho se propôs a avaliar o desempenho de um reator com leito de biomassa aderida de fluxo ascensional em escala plena (159 \'M POT.3\') e com aeração contínua a 7 m acima da base do reator para o tratamento do esgoto sanitário. O leito do reator era formado por carvão ativado granular, carvão antracitoso e areia. O trabalho foi dividido em duas etapas. Na primeira etapa foram feitos ensaios hidrodinâmicos que consistiram da curva de expansão/fluidificação para as biopartículas do leito do reator em escala plena e do ensaio de estímulo-resposta com o traçador \'NA\'CL\'. Na segunda etapa monitorou-se o comportamento do reator com leito de biomassa aderida operado com setor 1 (sem aeração) e setor 2 (com aeração) sobrepostos e foi utilizada a recirculação para expandir o leito. As curvas de expansão/fluidificação das biopartículas constituintes do leito do reator mostraram que o leito do reator no setor 1 encontrava-se sem expansão e no setor 2 estava expandido, sob as condições de operação determinadas para esse trabalho. Do ensaio com o traçador \'NA\'CL\', obtiverem-se tempo de detenção hidráulica médio (TDHM) de 18,45 h para o ensaio sem recirculação e com compressor desligado; e de 16,90 h para o ensaio com recirculação e compressor ligado. Os TDHM obtidos foram maiores que o TDH teórico (igual a 12 h), provavelmente devido à difusão do traçador no biofilme. A Etapa II foi dividida em duas fases, na fase 1 o TDH teórico médio foi de 12 h e na fase 2 foi de 16 h. Verificou-se baixa retenção de sólidos no sistema, visto que o efluente apresentou, durante a maior parte do período de monitoramento, concentrações de sólidos totais e sólidos suspensos totais superiores as do afluente. A maior eficiência de remoção de DQO de amostra bruta aconteceu na fase 2 e foi de 32% sob taxa de carregamento de 0,86kgDQObruta/\'M POT.3\'.d. Os valores médios de DQO de ) amostras filtradas do efluente foram iguais 119 e 116 mg \'O IND.2\'/L, o que equivale a remoções médias de 54% e 63%, respectivamente para a fase 1 e 2. A maior remoção DBO de amostra filtrada no sistema aconteceu na fase 1 e foi de 91%, com o efluente apresentando concentração de 19 mg \'O IND.2\'/L. Com relação à concentração de NTK, o sistema foi pouco eficiente em sua remoção e apresentou concentrações muito baixa de nitrogênio oxidado (menores que 1 mg \'NO IND.3\'POT.-1\'/L). O grau de amonificação foi de 89%, em média, quando considerou a concentração de NTK em amostra filtrada. Concluiu-se que o sistema não é eficiente na remoção de material orgânico e de nutrientes devido ao arraste de sólidos e material biológico no efluente. / This work aimed to evaluate the performance of a full scale up-flow attached biomass bed reactor (159 \'M POT.3\') and with continuous aeration at 7 m above bottom of the reactor to sanitary sewage treatment. The bed of the reactor was constituted for activated granular carbon, anthracite carbon and sand. The work was divided into two stages. In the first stage, hydrodynamics tests were made which consisted of the expansion/fluidization curve for the bioparticles of the bed of the full scale reactor and of the test of stimulus-response with tracer \'NA\'CL\'. In the second stage, it monitored the performance of the attached biomass bed reactor operated with overlapping sector 1 (without aeration) and sector 2 (with aeration) and it utilized the recirculation to expand the bed. The expansion/fluidization curves of the bioparticles of the bed of the reactor showed that the bed of the reactor in the sector 1 was without expansion and in the sector 2 was expanded, under the operating conditions determined for this work. Of the test with \'NA\'CL\' tracer obtained mean hydraulic detention time (HDTM) of 18,45 h for the test without recirculation and compressor off; and of 16,90 h for the test with recirculation and compressor on. The obtained HDTM were bigger than the theoretical HDT (equal at 12 h), probably due to at the diffusion of trace into biofilm. The stage II was divided into two phases, in the phase 1 mean theoretical HDT was of 12 h, and in the phase 2 was of 16 h. It verified low retention of solids in the system, since the effluent presented, during most of the monitoring period, concentrations of total solids and total suspended solids higher than the influent. The greater efficiency of COD removal of raw sample occurred in phase 2 and was of 32% under loading rate of 0,86kgCODraw/\'M POT.3\'.d. The mean amounts COD of filtered samples in the effluent were equal to 119 and 116mg\'O IND.2\'/L, which is equivalent ) to mean removals of 54% and 63%, respectively for phase 1 and 2. The higher efficiency of removal BOD filtered sample in the system was in phase 1 and was of 91%, with effluent presenting concentration of 19mg \'O IND.2\'/L. With respect to the TKN concentration, the system was little efficient in its removal and presented very low concentration of oxidized nitrogen (lower than 1mg \'NO IND.3\'POT.-1\'). The degree of ammonification was 89%, on average, when considered the TKN concentration in the filtered sample. It concluded that the system is not effective removing organic material and nutrients due to drag of solids and biological material in the effluent.
106

Higiene e cuidados com a genitália em mulheres com vulvovaginites = Hygiene and genital care of women with vulvovaginitis / Hygiene and genital care of women with vulvovaginitis

Bardin, Marcela Grigol, 1988- 26 August 2018 (has links)
Orientadores: Paulo César Giraldo, Cristina Laguna Benetti Pinto / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Ciências Médicas / Made available in DSpace on 2018-08-26T01:16:17Z (GMT). No. of bitstreams: 1 Bardin_MarcelaGrigol_M.pdf: 2975032 bytes, checksum: c14d12c0209845a33b97ae0599d148d9 (MD5) Previous issue date: 2014 / Resumo: INTRODUÇÃO: A vaginose bacteriana (VB) e a candidíase vaginal (CV) são as vulvovaginites (VV) mais frequentemente encontradas em mulheres durante o ciclo reprodutivo. Embora os tratamentos dessas VV estejam esclarecidos, a prevenção ainda é pouco estudada. Os hábitos de higiene e cuidados diários com a genitália feminina são fatores que podem influenciar o ecossistema vulvovaginal, facilitando a instalação dessas VV. OBJETIVO: Verificar os hábitos de lavagem, uso de absorventes higiênicos, práticas depilatórias, uso de piercings e tatuagens, tipo indumentária e atividades sexuais em mulheres com VV. MÉTODOS: Estudo de corte transversal utilizou questionário contendo 60 perguntas, divididas nos seguintes domínios: I ¿ Limpeza genital; II ¿ Uso de absorventes higiênicos; III ¿ Práticas depilatórias; IV ¿ Uso de piercings e tatuagens genitais; V ¿ Tipo indumentária e VI ¿ Atividades sexuais. Foram analisadas 307 mulheres de 18 a 45 anos, atendidas nos ambulatórios de um hospital universitário (Universidade Estadual de campinas, Brasil). Realizou-se exame ginecológico para diagnóstico de VB e CV por bacterioscopia e cultura de fungo, além de medir pH e realizar teste de Whiff. Os critérios de exclusão foram: uso de antibiótico até 15 dias antes da inclusão, antecedente de câncer, sorologia positiva para HIV e/ou sífilis e presença doença imunossupressora. Este estudo teve a aprovação do Comitê de Ética em Pesquisa da Unicamp sob número de protocolo 1836/2013 e todas as voluntárias assinaram o termo de consentimento livre e esclarecido previamente à participação neste estudo. A coleta de dados foi realizada no período de março a novembro de 2013. Para a análise estatística, consideraram-se dois grupos principais: mulheres sem e com vulvovaginites (presença de VB, CV e ambas) que foram comparados entre si. Também se realizou uma segunda análise de cada tipo de VV isoladamente (VB, CV e ambas associadas) versus mulheres sem vulvovaginites. Foram empregados os testes de Fischer e Qui-quadrado através do EPI INFO 0.5. Considerou-se nível de significância quando p<,05. RESULTADOS: Entre as 307 participantes, 46% foram diagnosticadas com VV presentes e 54% sem VV. Quando comparados estes grupos, não se encontraram diferenças significativas quanto à idade, IMC, escolaridade, número de gestações, número de partos, estado marital, raça, religião, uso de métodos contraceptivos, tabagismo, tempo fora de casa e queixas de dispareunia. A média de idade foi de 33,6 (±6,8) anos e de escolaridade 10,4 (±3,3) anos de estudo. A presença de VV esteve significativamente associada ao menor uso de produtos para higiene genital tais como sabonete líquido íntimo para higiene diária (p=,04) e lenço úmido para higiene pós-miccional (p=,04) e maior uso de sabonete bactericida para realização da lavagem genital durante o banho (<,0001). As mulheres com VV utilizaram mais calcinhas de tecido sintético (p<,05), apresentaram mais ciclos menstruais (p<,0001) que aquelas sem VV e apresentaram hábitos de uso de absorventes semelhantes. As mulheres com VB praticaram mais o sexo anal nos últimos 30 dias (p<,0001) e usavam mais substâncias erógenas (p<,02) que aquelas sem VV. Não houve diferenças significativas de frequência de relações sexuais, dispareunia, sexo oral e uso de lubrificantes entre os grupos estudados. A análise da depilação genital também não evidenciou diferenças significativas quanto ao método utilizado, motivação, frequência, área de depilação, irritabilidade vulvar, produtos pós-depilatórios e opinião sobre a influência da depilação genital sobre a saúde feminina. Apesar de ser um número baixo, mulheres com CV apresentaram mais tatuagens genitais que os demais grupos (p=,04) e apenas uma mulher apresentou piercing genital. CONCLUSÕES: Alguns hábitos de lavagem da genitália, a presença de ciclos menstruais, o uso de calcinhas de tecido sintético, relações sexuais anais e uso de substâncias erógenas na genitália se associaram à frequência de vulvovaginites. Especialmente estas últimas relacionadas aos hábitos sexuais estiveram associadas à presença de vaginose bacteriana. Os hábitos de uso de absorventes higiênicos e depilatórios não se associaram à presença de VV. Os adornos genitais foram raros, porém encontraram-se mais tatuagens genitais em mulheres com CV / Abstract: INTRODUCTION: Bacterial vaginosis (BV) and vaginal candidiasis (VC) are the most frequently vulvovaginitis (VV) encountered during in women at reproductive cycle. Although the treatments of VV are clear, prevention is still little studied. Hygiene habits and daily care with the female genitalia are factors that can influence the vulvovaginal ecosystem, and might facilitate the installation of these VV. MAIN: To investigate the genital washing habits, use of sanitary pads, genital hair removal, use of piercings and tattoos, clothing type and sexual activity in women with VV. METHODS: Cross-sectional study used a questionnaire containing 60 questions, divided into the following areas: I ¿ Genital Cleaning; II ¿ Use of sanitary pads; III ¿ depilatory practices; IV ¿ Use of genital piercings and tattoos; V ¿ clothing type and VI ¿ Sexual Activities. Were analyzed 307 women from 18 to 45 years, attended at two outpatient clinics of a university hospital (University of Campinas, Brazil). Gynecological exam was performed for collecting vaginal material for BV and VC diagnosis by Gram stain and culture of fungus, as well as measured pH and performed Whiff test. Exclusion criteria were: use of antibiotics within 15 days before enrollment, history of cancer, HIV positive and/or other immunosuppressive disease. This study was approved by the Ethics Committee of UNICAMP Research under protocol number 1836/2013 and all volunteers signed an informed consent form prior to their participation in this study. Data collection was conducted from March to November 2013. For statistical analysis, we considered two main groups: women with and without vulvovaginitis (presence of BV, VC and both) were compared to each other. It was also conducted a second analysis of each group of VV alone (BV, VC and both combined) versus women without vulvovaginitis. Statistical analysis used exact Fischer and chi-square tests by the EPI INFO 0.5. It was considered a significance level of p<.05. RESULTS: Among the 307 participants, 46% were diagnosed with VV and 54% without VV. When comparing these groups, there were no significant differences in age, BMI, duration of study, number of pregnancies, number of births, marital status, race, religion, use of contraceptives, smoking, time away from home and complaints of dyspareunia. The mean age was 33.6 (± 6.8) years of education and 10.4 (± 3.3) years of education. The presence of VV was significantly associated with lower use of genital hygiene products such as liquid soap for daily intimate hygiene (p=.04) and moist napkin as hygiene post urination (p=.04) and, on the other hand, increased use of antibacterial soap for daily genital wash (<.0001). Women with VV used more panties of synthetic fabric (p<.05), had more menstrual cycles (p<.0001) than those without VV and similar use of sanitary pads. Women with BV practiced more anal sex in the last 30 days (p<.0001) and used more erogenous substances (p<.02) than those without VV. There were no significant differences in frequency of sexual intercourse, dyspareunia, oral sex and using lubricants between groups. The analysis of genital hair removal also showed no significant differences in the method used, motivation, frequency, area of hair removal, vulvar irritability, post-depilatory used products, and opinion about the influence of genital waxing on women's health. Despite being a low number, women with genital VC had more tattoos than the other groups (p=.04) and only one woman had genital piercing. CONCLUSIONS: Some habits related to genitalia washing, the presence of menstrual cycles, the use of synthetic fabric underwear, anal intercourse and use of erogenous substances during sexual intercourse were associated with frequency of vulvovaginitis. Especially anal sex on the last 30 days previous to diagnosis and use of erogenous substances during sexual intercourse were specifically associated with the presence of bacterial vaginosis. Use of sanitary pads and hair removal habits were not associated with the presence of VV. The genital adornments were rare but genital tattoos were most common among women with VC / Mestrado / Fisiopatologia Ginecológica / Mestra em Ciências da Saúde
107

AVALIAÇÃO DE UM REATOR BIOLÓGIGO ROTATIVO DE CONTATO (RBC) APLICADO AO TRATAMENTO DE EFLUENTE DE UM ABATEDOURO DE SUÍNOS E AVES. / EVALUATION OF ROTATING BIOLOGICAL CONTACTORS (RBC) APPLIED TO THE TREATMENT OF EFFLUENT FROM A PIG AND POULTRY SLAUGHTERHOUSE

Schwerz, Bervey 14 March 2012 (has links)
With the expansion of industrial society, began a intense growth of production of waste, creating a latent issue, referring to allocate up correctly all waste generated during the manufacturing process. Specifically, the meat processing generates during its many stages a huge flow of wastewater. An alternative for the treatment of this type of waste are rotating biological contactors. This paper, has for objective, at the construction and application of a RBC to improve performance in the treatment of an industrial effluent from the slaughterhouse of pigs and poultry. It was built a reactor 4L and aerobic sludge was used as inoculum system. The analysis period amounted to 73 days. As results were obtained an efficiency of 84.46% with a removal 1.64 g DBO.m-2 and 88.3% for an HRT of 4 h and surface loading of 124 g DQO.d-1.m-2 for BOD and COD respectively, corresponding to organic matter. On removal of nutrients, the system obtained in an efficiency of 92.02% and a surface charge removed from 8.35 g Nd-1m-2 for nitrogen and 75.66% efficiency and removal of superficial 1.5 g Pd-1.m-2, for analysis of phosphorus. In summary, the RBC could efficiently treat an effluent to obtain satisfactory results in removing the organic load and nutrients. / Com a expansão da sociedade industrial, se iniciou uma geração de resíduos de forma intensa, surgindo uma questão latente, referente a destinar-se corretamente todos os resíduos gerados durante o processo industrial. Mais especificamente, o processamento de carne gera durante suas inúmeras etapas uma enorme vazão de efluentes líquidos. Uma alternativa para o tratamento deste tipo de resíduo são os reatores de biodiscos. Este trabalho tem por objetivo a construção e aplicação de um RBC para avaliar seu desempenho no tratamento de um efluente industrial proveniente do abate de suínos e aves. Foi construído um reator de 4L e utilizado lodo aeróbio como inóculo do sistema. O período de análise correspondeu a 73 dias. Como resultados foram obtidos uma eficiência de 84,46% com uma remoção de 1,64 g DBOm-2 e 88,3%, para um TRH de 4 h e carregamento superficial de 124 g DQOd-1m-2, para DBO e DQO respectivamente, correspondendo a matéria orgânica. Na remoção de nutrientes, o sistema obteve um rendimento de 92,02% e uma carga superficial removida de 8,35 g Nd-1m-2 para o nitrogênio e a eficiência de 75,66% e a remoção superficial é de 1,5 g Pd-1m-2, para as análises de fósforo total. Em resumo, o RBC conseguiu tratar de forma eficiente um efluente de forma a obter resultados satisfatórios na remoção da carga orgânica e nutrientes.
108

Recolha robotizada de rolhas

Silva, João Ricardo Almeida de Sousa e January 2012 (has links)
Tese de mestrado integrado. Engenharia Electrónica e de Computadores. Faculdade de Engenharia. Universidade do Porto. 2012
109

Contribuições para o estudo de descomissionamento de barragens. / Contribuition for the study of dam decommissioning.

Pinto, Amarílio Costa e Carvalho 11 August 2010 (has links)
Dada a importância estratégica das barragens no Brasil e à disputa de interesses, o descomissionamento dessas estruturas é um assunto inevitável a ser discutido. Um conjunto de casos de descomissionamento de outros países é apresentado e ilustra de maneira abrangente essa questão pouco discutida e ainda não legislada no Brasil. Uma metodologia para avaliação da necessidade de descomissionamento com base no potencial de risco oferecido foi proposta e aplicada aos barramentos constantes do Cadastro de barragens das bacias PCJ, no estado de São Paulo. Apesar de a metodologia não poder ser aplicada em sua total extensão devido à insuficiência de dados do cadastro, é possível perceber quando algumas barragens encontram-se descuidadas, sem nenhum tipo de monitoramento podendo ser elegíveis para escomissionamento. / Due to the importance of dams in Brazil and to different interests, dam decommissioning is an unavoidable issue to be discussed. Some examples of dam removal in some countries are presented to generally elucidate this subject that still hasnt been acknowledged, neither legislated in Brazil. A methodology for evaluation of decommissioning demanding, based on the potential risk offered by dams has been set up and tested over a few dams that are constituent of a data basis of dams of Piracicaba-Capivari-Jundiaí (PCJ) basins, in São Paulo state. Despite the fact that the methodology couldnt be used at its full length due to lack of field data, it has been realized when some dams of the data basis are most despised, recklessly maintained and are contestant for decommissioning.
110

Caracterização do cromo presente no lodo de galvanoplastia: avaliação técnica e econômica de processos de remoção / Characteristics of chromium from electroplating sludge: technical and economic evaluation of removal processes

Alves, Lucas Campaner 05 February 2016 (has links)
O lodo gerado em processos de galvanoplastia é classificado pela ABNT NBR 10.004/04 como perigoso (classe I). Na literatura encontram-se poucos estudos referentes à recuperação do cromo presente no lodo gerado em sistemas de tratamento de efluentes de indústrias de galvanoplastia. Neste sentido, o presente estudo avaliou a remoção do cromo presente no lodo de galvanoplastia por meio de dois processos, visando avaliar à eficiência técnica e a viabilidade econômica de ambos. O Processo 1 consistiu na remoção do cálcio utilizando o ácido cítrico, seguida de lixiviação ácida. Na etapa de oxidação, variou-se a temperatura em 40ºC, 60ºC e 80ºC e no tempo de 30, 60 e 90 minutos, tendo em vista que a eficiência do processo de oxidação depende da temperatura e tempo. Nesta etapa do processo as concentrações de peroxido de hidrogênio (H2O2) utilizadas foram de 1,50, 3,00 e 4,50 mol.L-1. O Processo 2 realizou a oxidação do cromo sem efetuar as etapas de extração do cálcio e a lixiviação ácida. A oxidação do cromo ocorreu pelo mesmo método apresentado no Processo 1. A caracterização elementar da amostra determinou que o principal elemento constituinte do lodo é o cálcio (20,05% em massa), e que dentre os metais pesados destacam-se o cromo e o níquel (6,52% e 4,33% em massa, respectivamente). A maior eficiência de remoção do cálcio foi obtida na razão mássica de 8,00 (ácido cítrico/hidróxido de cálcio), com 51,76% em massa, seguida pela razão mássica de 5,50 com 36,75% em massa e 2,50 com 24,83% em massa. O melhor resultado de oxidação do cromo no Processo 1 foi obtido com tempo de 30 minutos, temperatura de 60ºC e concentração de peroxido de hidrogênio de 3,00 mol.L-1, com eficiência de 41,09% em massa. No Processo 2, obteve-se a remoção de 37,96% em massa de cromo a temperatura de 80ºC, por uma hora e 3,00 mol.L-1 de peróxido de hidrogênio. Avaliando os custos para remoção do cromo dos dois processos, determinou-se que o Processo 1 foi mais oneroso que o 2, porém ambos não apresentaram viabilidade econômica para aplicação em escala industrial. Nos dois processos efetuou-se a oxidação do cromo presente no lodo de galvanoplastia, permitindo a sua remoção parcial neste resíduo. Com isso obtiveram-se ganhos ambientais, pela diminuição deste elemento no resíduo de galvanoplastia, que na maioria das vezes é disposto em aterros classe I, gerando um passivo ambiental. / The sludge generated in electroplating processes is classified by NBR 10.004/04 as a hazardous material (class I). In the literature, few studies report the recovery of chromium present in the electroplating sludge generated in the industries. In this sense, the present study conducted the removal of chromium in the electroplating sludge through two different processes, aiming to evaluate their efficiency and economic viability. The first process removed calcium through the use of citric acid being performed by varying the ratio of citric acid/calcium hydroxide (2.5, 5.5 and 8.0). Then, were performed the leaching of the samples. According to the literature, the efficiency of the oxidation process varies depending on the reaction temperature, time and concentration of hydrogen peroxide. For this reason, samples were heated to a temperature ranging from 40°C, 60°C and 80°C. Also, were conducted variations in the concentrations of hydrogen peroxide (1.5, 3.0 and 4.5 mol.L-1) and reaction time (30, 60 and 90 minutes). The second Process consisted in the chrome recovery by using the galvanic sludge without removal of the calcium and acid leaching. The chrome oxidation occurred by the same method shown in Process 1. Elemental characterization of the samples determined that the primary sludge constituent was calcium (20.05% by weight), and in terms of heavy metals, the chromium and the nickel (6.52% and 4.33% by mass, respectively). Most of calcium removal efficiency was obtained at a rate of 8 with 51.76% by mass, then the ratio of 5.50 to 36.75% by mass and 2.50 to 24.83% by mass. The best oxidation result of chromium in Process 1 was obtained using a time of 30 minutes, 60°C and hydrogen peroxide concentration of 3 mol.l-1, with 41.09 wt% efficiency. In Process 2 was obtained the removal of 37.96% by mass of chromium temperature of 80°C, for one hour and 3,00 mol.l-1 of hydrogen peroxide. Evaluating the costs for chrome removal of the two processes was determined that the Process 1 was more costly than 2, but both showed no economic feasibility for implementation on an industrial scale. However, in both cases occurred the oxidation of chromium present in the electroplating sludge, allowing its removal from the residue. Thus, environmental gains have been achieved by the reduction of this element in electroplating waste, which mostly is intended for landfill class I, generating an environmental liability.

Page generated in 0.0657 seconds