• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1037
  • 16
  • 15
  • 15
  • 14
  • 13
  • 10
  • 5
  • 2
  • Tagged with
  • 1072
  • 646
  • 396
  • 311
  • 277
  • 275
  • 176
  • 145
  • 144
  • 123
  • 115
  • 111
  • 108
  • 96
  • 93
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
291

Avaliação crítica de ambientes em eselecimentos assistenciais de saúde / Critical assessment of environments in health care eslishments

Araujo, Eliete de Pinho January 2008 (has links)
Made available in DSpace on 2012-09-05T18:23:43Z (GMT). No. of bitstreams: 2 license.txt: 1748 bytes, checksum: 8a4605be74aa9ea9d79846c1fba20a33 (MD5) 331.pdf: 6077221 bytes, checksum: 8dad97e035edb79ff9aeb060bb2fde3d (MD5) Previous issue date: 2008 / Este trabalho apresenta um estudo referente à análise crítica, no sentido decontribuir para a saúde. Foram abordados os conceitos de saúde, direito e leis, assim como a apresentação da legislação pertinente aos temas. Os temas deste estudo foram: o sistemade ar condicionado, os resíduos das processadoras de Raios X e o reúso da água. A idéia de implantar a Estação de Tratamento de Esgoto (ETE), tratando o esgoto sanitário e utilizando as águas recuperadas nas instalações hospitalares e na limpeza, lavagem epequenas obras do hospital é inovadora. Foram estudados o Hospital Estadual Carlos Chagas (HECC), no Rio de Janeiro, o Hospital Regional do Paranoá (HRPA), em Brasília, e o St. Paul Hospital (StPH), em Vancouver, Canadá. O objetivo é fazer uma avaliaçãocrítica de ambientes e das instalações prediais em Eselecimentos Assistenciais de saúde (EAS): analisar o sistema de ar condicionado, nos ambientes climatizados artificialmente;analisar o descarte dos produtos químicos oriundos das processadoras de filmes radiográficos no meio ambiente; propor a implantação do reúso da água proveniente da Estação de Tratamento de Esgoto e sugerir melhorias referentes aos três objetivos citados anteriormente. O método utilizado foi: 1) fazer medições de temperatura do ar e da água nos ambientes climatizados artificialmente e nas máquinas (fan-coil), em diferentes datas, abrangendo as quatro estações climáticas anuais, assim como analisar e propor os materiais de acabamento adequados nas centrais e salas de ar condicionado, verificar a limpeza dos dutos de condução e retorno do ar e analisar os laudos técnicos laboratoriais do ar; 2)verificar o sistema de descarte do produto químico, oriundo das processadoras para o meio ambiente; 3) analisar os espaços disponíveis nos hospitais para implantar a ETE e oreservatório de reúso de água, avaliar as análises do produto e sugerir o reúso nas instalações prediais, conforme os resultados. / Foi utilizada a avaliação pós-ocupação (APO) por meio de questionários aplicados aos usuários / funcionários das unidades estudadas, em diversos períodos do ano. Pelos resultados encontrados, variações internas de temperaturas do ar de 10º C e 12,5º C no HECC, de 11,4º C no HRPA e de 6º C no StPH, os dois hospitais do Brasil necessitam de ajustes no sistema de ar condicionado e o St. PH mostroumelhores condições internas de conforto térmico para o usuário. Fizeram a limpeza dos dutos por meio de robô e outro equipamento. O hospital do Canadá, embora nunca tenha feito limpeza robotizada nos dutos, foi o que melhores condições de conforto ambiental apresentou. Os produtos químicos descartados tiveram resultados diferentes nos trêshospitais. O HECC está em melhores condições seguras de trabalho e para o meio ambiente, e o do Canadá possui um sistema sem revelação de filme radiográfico, pois é digital. Quanto às ETEs, o HECC já a possui, só precisando fazer ajustes, o HRPA não tem, será proposta e é de interesse da Secretaria de Saúde local implantá-la e o StPH não tem e não mostrou interesse em construí-la. Os reservatórios de água de reúso nos dois hospitais brasileiros deverão ser construídos. Foram propostos manuais práticos de implantação e manutenção, além da realização de seminários relativos aos temas nas Secretarias de Saúdedo Rio de Janeiro e do Distrito Federal. / Conclui-se que, em relação aos três temas, os procedimentos adequados e as Normas de Saúde devem ser seguidos nos eselecimentos de saúde, conforme os Manuais Práticos propostos, e o Estado deve proporcionar condições de instalação e manutenção adequadas, além de fiscalizar e aplicar as penas cabíveis aos infratores, em detrimento da saúde pública. O olhar da arquitetura para a prevenção é ocaminho a ser seguido. A questão ambiental é fator fundamental, portanto, os três temas, ar condicionado, resíduos e esgoto e reúso de água estão relacionados ao meio ambiente,refletindo na saúde pública.
292

Avaliação das tensões residuais de soldagem em tubulações de pequeno diâmetro usadas em refinaria de petróleo / Welding Residual Stress Evaluation of Small Size Pipes Used in Petroleum Refinering

Silva, Cleiton Carvalho January 2007 (has links)
SILVA, Cleiton Carvalho. Avaliação das tensões residuais de soldagem em tubulações de pequeno diâmetro usadas em refinaria de Petróleo. 2007. 173 f. Dissertação (Mestrado em Engenharia e Ciência de Materiais) - Centro de Tecnologia, Universidade Federal do Ceará, Fortaleza, 2007. / Submitted by Marlene Sousa (mmarlene@ufc.br) on 2011-07-08T18:31:23Z No. of bitstreams: 1 2007_dis_ccsilva.pdf: 19425141 bytes, checksum: 3e8e0027e5b3a676e1aa1113e28a5f6d (MD5) / Approved for entry into archive by Marlene Sousa(mmarlene@ufc.br) on 2011-07-08T18:31:43Z (GMT) No. of bitstreams: 1 2007_dis_ccsilva.pdf: 19425141 bytes, checksum: 3e8e0027e5b3a676e1aa1113e28a5f6d (MD5) / Made available in DSpace on 2011-07-08T18:31:43Z (GMT). No. of bitstreams: 1 2007_dis_ccsilva.pdf: 19425141 bytes, checksum: 3e8e0027e5b3a676e1aa1113e28a5f6d (MD5) Previous issue date: 2007 / The aim of this work was to evaluate the behavior of welding residual stress in small size pipes of ASTM A106 Gr. B steel, welded by manual and automatic GTAW processes. It was also evaluated the effect of the welding heat input on residual stress profile, as well as to correlate the results with microstructure and hardness. The residual stress measurement was accomplished through X-ray diffraction, using a minidiffractometer for measurement in field. Metallographics analysis were accomplished in the traverse section of the welded joint, using optic microscopy and scanning electron microscopy. The microhardness profiles in the outer and inner surfaces of pipe were determined. The results showed that the measures of residual stress by X-ray diffraction with minidiffractometer for applications in field was shown quite effective in the residual stress profile determination, however, it is necessary the accomplishment of diffractograms fittings by analytic functions, to determine the correct peak localization, reducing the measures error. The measurements of the axial residual stress accomplished in the outer surface pipes showed that the profile is formed by compressive stresses in the welds region (fusion zone and heat affected zone - HAZ) and for tension stresses in the areas more distant of weld bead. High levels of compressive axial residual stress were observed in the outer surface of small size pipes, located in the welds region, which can represent a critical situation, because the linear behavior of the through-thickness residual stress due to “tourniquet” effect is consensual and, therefore, indicates the presence of high levels of tension residual stress in the inner surface, especially in the root weld metal and HAZ. The welding heat input of the finish pass caused an intense grain refining and a significant reduction of hardness of the weld metal in the inner surface, exception of 2" diameter sample welded with high heat input. None of the welded samples presented values of hardness above the maximum established for standard, which is 248 HV, showing that the fact of the welded joint to present low hardness, it does not necessarily represent that this is not subject to a high level of residual stress. / Este trabalho teve como objetivo, avaliar o comportamento das tensões residuais em tubulações de aço ASTM A106 Gr. B com pequeno diâmetro, soldada pelos processos TIG manual e automático. Buscou-se também avaliar o efeito do aporte térmico sobre o perfil de tensões, bem como correlacionar os resultados com a microestrutura e dureza. A medição das tensões foi realizada através de difração de raio-X, utilizando um minidifratômetro empregado para medição em campo. Análises metalográficas foram realizadas na seção transversal da junta, através de microscopia ótica e microscopia eletrônica de varredura. Foram levantados os perfis de microdureza nas superfícies externa e interna. Os resultados mostraram que a medição de tensões residuais por difração de raio-X, usando o minidifratômetro para aplicações em campo, é eficaz na determinação do perfil de tensões, contudo, é necessária a realização de ajustes dos difratogramas por funções analíticas, para determinar a correta localização do pico de difração de raio-X, reduzindo o erro das medidas. As medições das tensões residuais axiais realizadas na superfície externa dos tubos mostraram que o perfil é formado por tensões compressivas na região da solda (zona fundida e zona afetada pelo calor) e por tensões trativas nas regiões mais afastadas. Foram observados elevados níveis de tensões residuais axiais compressivas na superfície externa de tubos de parede fina, na região da solda, os quais podem representar uma situação crítica, visto que o comportamento linear das tensões ao longo da espessura devido ao efeito torniquete é consensual e, portanto, isso indica a presença de elevados níveis de tensões residuais de tração no metal de solda e na zona afetada pelo calor. O ciclo térmico do passe de acabamento ocasionou um intenso refino de grão e uma significativa redução de dureza, especialmente no metal de solda e na superfície interna dos tubos, a exceção das amostras de 2” de diâmetro soldadas com elevado aporte térmico. Nenhuma das amostras soldadas apresentou valores de dureza acima do máximo estabelecido por norma, que é de 248 HV, mostrando que o fato da junta apresentar dureza baixa, não necessariamente representa que esta não esteja sujeita a um elevado nível de tensões residuais.
293

Caracterização do lodo gerado em estações de tratamento de esgoto sanitário da região metropolitana de Fortaleza visando sua utilização na agricultura / Characterization of sludge generated at wastewater treatment plants health of the metropolitan region of Fortaleza aiming its use in agriculture

Bezerra, Keyve Mayane 27 August 2014 (has links)
BEZERRA, K. M. Caracterização do lodo gerado em estações de tratamento de esgoto sanitário da região metropolitana de Fortaleza visando sua utilização na agricultura. 2014. 133 f. Dissertação (Mestrado em Engenharia Civil: Saneamento Ambiental) – Centro de Tecnologia, Universidade Federal do Ceará, Fortaleza, 2014. / Submitted by Marlene Sousa (mmarlene@ufc.br) on 2015-04-10T14:42:46Z No. of bitstreams: 1 2014_dis_kmbezerra.pdf: 3552208 bytes, checksum: 810875a07b96947113d4c597e6077787 (MD5) / Approved for entry into archive by Marlene Sousa(mmarlene@ufc.br) on 2015-04-15T17:41:02Z (GMT) No. of bitstreams: 1 2014_dis_kmbezerra.pdf: 3552208 bytes, checksum: 810875a07b96947113d4c597e6077787 (MD5) / Made available in DSpace on 2015-04-15T17:41:02Z (GMT). No. of bitstreams: 1 2014_dis_kmbezerra.pdf: 3552208 bytes, checksum: 810875a07b96947113d4c597e6077787 (MD5) Previous issue date: 2014-08-27 / The high production of sludge in large urban centers, coupled with the need for proper disposal, has generated serious environmental problems in the country. Most of sludge produced worldwide is intended for incineration, landfilling and agricultural use. Among the alternatives to reuse a viable technique is to use as organic fertilizer because the nutrients contained, making it an input with high economic value. The aim of this study was to characterize the sludge from the wastewater treatment plants located in the Metropolitan Region of Fortaleza, in order to reuse in agriculture and providing alternative routes to their final destination. Monthly samples of sludge were carried out in the period August to November 2013 After collection, the analysis of the parameters was performed: temperature, pH, total alkalinity, conductivity, alkalinity of Volatile Acids (AAV), Volatile Fatty Acids (VFA) , specific weight, moisture content, solids and nitrogen, total phosphorus, chemical oxygen demand (COD), and Total Coliform and Escherichia Coli and inorganic substances (heavy metals and some nutrients). The results indicate that the sludge contains nutrients such as nitrogen and phosphorus necessary for the growth of plants and may be used as a form of recycling in agriculture, providing an environmentally friendly target, provided that pass through a suitable treatment for the removal or reduction of pathogens before its application. All slurries exhibited stable for agricultural use, whereas in one study SV / ST ratio less than 0.70 was found. According to the concentration of heavy metals, they could be reused in agriculture, as had lower values ​​compared with the limits established in legislation braseileira, but no restriction, just, septic sludge, due to the concentration range of zinc exceeds the maximum limit concentration permitted by CONAMA Resolution No. 375/2006. / A elevada produção de lodo nos grandes centros urbanos, aliada à necessidade de destinação final adequada, tem gerado sérios problemas ambientais no país. A maior parte do lodo produzida no mundo é destinada à incineração, disposição em aterros e uso agrícola. Dentre as alternativas de reaproveitamento, uma técnica viável é a utilização como adubo orgânico, devido aos nutrientes contidos, tornando-o um insumo com elevado valor econômico. O objetivo desse trabalho foi caracterizar o lodo proveniente de estações de tratamento de esgotos sanitários situadas na Região Metropolitana de Fortaleza, visando à reutilização na agricultura e possibilitando rotas alternativas para seu destino final. Foram realizadas coletas mensais de lodo no período de agosto a novembro de 2013. Após a coleta, foi realizada a análise dos parâmetros: temperatura, pH, alcalinidade total, condutividade elétrica, Alcalinidade de Ácidos Voláteis (AAV), Ácidos Graxos Voláteis (AGV), peso específico, teor de umidade, série de sólidos e nitrogênio, fósforo total, Demanda Química de Oxigênio (DQO), além de Coliforme total e Escherichia Coli e substâncias inorgânicas (metais pesados e alguns nutrientes). Os resultados obtidos indicam que os lodos contêm nutrientes, como nitrogênio e fósforo, necessários ao crescimento das plantas, podendo ser utilizados como forma de reciclagem na agricultura, proporcionando um destino ambientalmente favorável, desde que passe por um tratamento adequado para a remoção ou redução dos patógenos antes de sua aplicação. Todos os lodos apresentaram-se estáveis para fins de utilização agrícola, visto que no estudo foi encontrada uma relação SV/ST menor que 0,70. De acordo com a concentração de metais pesados, eles poderiam ser reutilizados na agricultura, pois apresentaram baixos valores em relação aos limites estabelecidos na legislação braseileira, porém há restrição, apenas, ao lodo séptico, devido à faixa de concentração do zinco exceder o limite máximo de concentração permitido pela Resolução nº CONAMA 375/2006.
294

Avaliação de micropoluentes emergentes em esgotos e águas superficiais / Evaluation of emerging organic micropollutants in sewage and surface water

Souza, Neyliane Costa de 11 1900 (has links)
SOUZA, N. C. de. Avaliação de micropoluentes emergentes em esgotos e águas superficiais. 2011. 166 f. Tese (Doutorado em Engenharia Civil - Saneamento Ambiental) - Centro de Tecnologia, Universidade Federal do Ceará, Fortaleza, 2011. / Submitted by Marlene Sousa (mmarlene@ufc.br) on 2012-02-28T19:43:37Z No. of bitstreams: 1 2011_tese_ncsouza.pdf: 3004356 bytes, checksum: 1fb2dc46b73bd3f09a8920c22635e2a8 (MD5) / Approved for entry into archive by Marlene Sousa(mmarlene@ufc.br) on 2012-02-28T19:44:35Z (GMT) No. of bitstreams: 1 2011_tese_ncsouza.pdf: 3004356 bytes, checksum: 1fb2dc46b73bd3f09a8920c22635e2a8 (MD5) / Made available in DSpace on 2012-02-28T19:44:35Z (GMT). No. of bitstreams: 1 2011_tese_ncsouza.pdf: 3004356 bytes, checksum: 1fb2dc46b73bd3f09a8920c22635e2a8 (MD5) Previous issue date: 2011-11 / In Brazil, studies evaluating emerging micropollutants in environmental matrices such as sewage and hospital wastewater, as well as surface waters, are still quite incipient as well as the removal of these compounds in low cost Wastewater Treatment Plants (WWTPs) such as stabilization ponds, as well as in activated sludge systems or anaerobic/aerobic compact systems. This work aimed to investigate the presence of micropollutants in environmental matrices such as sewage and hospital wastewaters, and in surface waters. Additionally, this study evaluated the removal of these compounds in low-cost WWTPs and studied the advanced oxidation process (AOP) – UV/H2O2 – as a post-treatment option. The main emerging micropollutants studied were: 2,4,6-trichlorophenol, pentachlorophenol, caffeine (CAF), dipyrone (DIP), sodium diclofenac (DCF), bis (2-ethylhexyl) phthalate (DEHP), estrone (E1), 17β-estradiol (E2), estradiol acetate (EA2), 17α-ethinyl estradiol (EE2) and cholesterol (CHO). The samples were collected from WWTPs located in Fortaleza and its metropolitan region. The receiving surface waters investigated were: Maranguapinho River and Paupina Creek. For the pre-concentration studies of micropollutants, solid phase extraction (SPE) with C-18 cartridges was used, as well as the liquid-liquid extraction (LLE) method. The SPE technique was the most efficient method in concentrating the majority of emerging micropollutants, and the LLE proved to be the best technique for organochlorine compounds. Optimization studies were performed to detect the ideal conditions to determine the compounds by using gas chromatography (GC) and gas chromatography-mass spectrometry (GC/MS) techniques. In all wastewater samples pharmaceuticals and endocrine disrupting compounds were identified, and the range of effluent concentrations were: CAF (3.0-15.8 μg/L), DIP (0.3 μg/L), DCF (1.9 μg/L), DEHP (0.01-8.5μg/L), E1 (0.04-1.7 μg/L), E2 (0.03-4.0 μg/L), EA2 (0.14-9.3 μg/L), EE2 (1.0 μg/L) and CHO (0.01-6.2 μg/L). Endocrine disrupting compounds were identified in the Maranguapinho River and Paupina Creek. The wastewater treatment in the WWTPs was not enough for the complete removal of all micropollutants studied; however, the efficiency level for most of compounds was above 50%. Regarding the evaluation in stabilization ponds systems, the study revealed good removal of micropollutants in systems composed of anaerobic pond followed by facultative and maturation ponds, in which the lowest efficiency levels were verified when a single facultative pond was present. The evaluation of the AOP as a post-treatment option by multivariate factorial design showed that the optimal conditions for the removal of emerging micropollutants were acidic pH (pH 3), hydrogen peroxide concentration above 400 mg/L and hydraulic retention times in the reactor above 50 minutes. / No Brasil, estudos de avaliação de micropoluentes emergentes em matrizes ambientais como esgotos sanitários e hospitalares, e corpos de água, ainda são bastante incipientes, assim como a remoção desses compostos em Estações de Tratamento de Esgotos (ETEs) de baixo custo como lagoas de estabilização, assim como em sistemas de lodos ativados e sistemas anaeróbio-aeróbio compactos. O presente trabalho teve como objetivo geral investigar a presença de micropoluentes em matrizes ambientais como esgotos sanitários e hospitalares, e água superficial, avaliar a remoção destes compostos em ETEs de baixo custo e aplicar o processo de oxidação avançada (POA) UV/H2O2 como opção de pós-tratamento. Os principais micropoluentes emergentes estudados foram: 2,4,6-triclorofenol, pentaclorofenol, cafeína (CAF), dipirona (DIP), diclofenaco de sódio (DCF), bis (2-etil-hexil) ftalato (DEHP), estrona (E1), 17β-estradiol (E2), β-estradiol 17-acetato (EA2), 17α-etinilestradiol (EE2) e colesterol (COL). As amostras foram coletadas em ETEs localizadas em Fortaleza e em sua região metropolitana. Os corpos receptores investigados foram o Rio Maranguapinho e o Riacho Paupina. Para a pré-concentração dos micropoluentes utilizou-se extração em fase sólida (SPE) com cartuchos C-18 e extração líquido-líquido (ELL). A SPE foi a técnica mais eficiente na concentração da maioria dos micropoluentes emergentes, e a ELL se mostrou a melhor técnica para compostos organoclorados. Foram realizados estudos de otimização das condições de detecção dos compostos pelo uso de técnicas de cromatografia gasosa acoplada à espectrometria de massas (GC/MS). Foram identificados compostos farmacêuticos e desreguladores endócrinos em todas as amostras de esgotos com as seguintes faixas de concentrações efluentes: CAF (3,0-15,8 μg/L), DIP (0,3 μg/L), DCF (1,9 μg/L), DEHP (0,01-8,5μg/L), E1 (0,04-1,7 μg/L), E2 (0,03-4,0 μg/L), EA2 (0,14-9,3 μg/L), EE2 (1,0 μg/L) e COL (0,01-6,2 μg/L). Nos dois corpos receptores estudados (Rio Maranguapinho e Riacho Paupina) foram identificados desreguladores endócrinos. Os tratamentos realizados pelas ETEs não foram suficientes para remoção total de todos os micropoluentes estudados, no entanto, a eficiência para a maioria dos compostos foi acima de 50%. Em se tratando da avaliação em sistemas de lagoas de estabilização, o estudo revelou boas eficiências de remoção em sistemas constituídos de lagoa anaeróbia seguida de facultativa e de maturação, sendo os menores valores de remoção alcançados quando uma única lagoa facultativa primária estava presente. A avaliação do uso do POA por meio do planejamento fatorial multivariado revelou que as melhores condições para remoção de micropoluentes emergentes foram pH ácido (pH 3), concentração de peróxido de hidrogênio acima de 400 mg/L e tempos de detenção hidráulica no reator acima de 50min.
295

Avaliação de tensões residuais de soldagem em chapas planas do aço estrutural ASTM A516 G70 / Welding residual stress evaluation in flat samples of structural ASTM A516 G70 steel

Oliveira, George Luiz Gomes de 15 January 2009 (has links)
OLIVEIRA, G. L. G. Avaliação de tensões residuais de soldagem em chapas planas do aço estrutural ASTM A516 G70. 2009. 123 f. Dissertação (Mestrado em Ciência de Materiais) – Centro de Tecnologia, Universidade Federal do Ceará, Fortaleza, 2009. / Submitted by Marlene Sousa (mmarlene@ufc.br) on 2016-03-31T17:20:13Z No. of bitstreams: 1 2009_dis_glgoliveira.pdf: 24809108 bytes, checksum: 2166d82c6a23f05c49867432431a26d6 (MD5) / Approved for entry into archive by Marlene Sousa(mmarlene@ufc.br) on 2016-04-07T17:40:03Z (GMT) No. of bitstreams: 1 2009_dis_glgoliveira.pdf: 24809108 bytes, checksum: 2166d82c6a23f05c49867432431a26d6 (MD5) / Made available in DSpace on 2016-04-07T17:40:03Z (GMT). No. of bitstreams: 1 2009_dis_glgoliveira.pdf: 24809108 bytes, checksum: 2166d82c6a23f05c49867432431a26d6 (MD5) Previous issue date: 2009-01-15 / The main aim of this work was to evaluate the employed welding procedure effect on the level and profile of the final residual stresses on a multipass joint, with emphasis in the welding energy, chamfer and used welding technique. It was also evaluated the effect of the welding current and speed on these stresses, as well as it was correlated the results with microstructure and microhardness. The residual stress measurement was accomplished through X-ray diffraction, using a minidiffractometer for measurement in field. Metallographic analysis was accomplished in the transverse section of the welded joint, using optic microscopy and scanning electron microscopy. It were determined the microhardness profiles in the traverse section of the welded joint. The results showed that the multipass welding residual stresses on the surface of the analyzed samples are compressive in the weld metal and tensile in the HAZ. In the weld root, the welding residual stresses are tensile as in the weld metal as in the HAZ. The welding energy showed a non-linear relationship with the founded residual stresses and it was observed that the most influential parameter was the welding speed, what can be a trouble, since this parameter is the less controlled in manual weldings. The semi-v chamfered samples were the ones that present the fewer levels of residual stresses, due to the stress relief created by plastic deformations during the welding, what do not occur in the X chamfered samples. The double layer technique showed that it can be used in the welding of ASTM A516 Gr70 steel, because, besides promote a refinement and a drawing back of the CG-HAZ, it increased compressive residual stress in the whole surface of the analyzed samples. The founded microstructures and microhardness were similar for all samples and it has believed that the acicular ferrite founded in the weld metal was one of the the main causes for the compressive characteristics of the welding residual stresses in the joints / O objetivo principal desse trabalho foi avaliar o efeito do procedimento de soldagem empregado, com foco na energia de soldagem, no tipo de chanfro empregado e na técnica de soldagem utilizada, sobre o nível e a distribuição das tensões residuais resultantes em junta submetida à soldagem multipasse. Foi avaliado também o efeito da corrente e da velocidade de soldagem de forma isolada sobre estas tensões, bem como a correlação desses resultados com a microestrutura e dureza encontrada. As tensões residuais foram medidas utilizando a técnica de difração de raios-x, através de um minidifratômetro para medição em campo. As análises metalográficas foram realizadas na seção transversal da junta, através de microscopia ótica e microscopia eletrônica de varredura. Foram levantados os perfis de microdureza na seção transversal da junta. Os resultados mostraram que as tensões residuais originadas da soldagem multipasse na superfície das amostras analisadas são compressivas no metal de solda e trativas da ZAC. As tensões residuais encontradas na raiz das amostras analisadas se mostraram trativas tanto no metal de solda quanto na ZAC. A energia de soldagem apresentou uma relação não linear com as tensões residuais encontradas, sendo encontrado que o parâmetro que apresentou maior influência foi a velocidade de soldagem, o que representa um problema, pois geralmente tal parâmetro é o menos controlado nas soldagens manuais. As amostras chanfradas em meio-v foram as que apresentaram os menores níveis de tensões residuais, devido a alívios de tensão gerados por deformações plásticas geradas durante a soldagem, fato que não ocorre nas amostras chanfradas em X. A técnica da dupla camada mostrou-se uma ferramenta bastante útil à soldagem do aço ASTM A516 Gr70, pois além de promover o refinamento e revenimento da ZAC-GG das amostras soldadas, acrescentou tensões residuais compressivas ao longo de toda a superfície analisada das amostras. As microestruturas e durezas encontradas nas juntas foram bem similares para todas as amostras, sendo a ferrita acicular encontrada no metal de solda uma das prováveis causas da característica compressiva das tensões residuais encontradas
296

Estudo da otimização do processo H2O2/UV para degradação do corante remazol vermelho RB 133% / Study of the process optimization h2O2/UV for degradation of the dye Remazol Red RB 133%

Ribeiro, Jefferson Pereira 25 May 2011 (has links)
RIBEIRO, J. P. Estudo da otimização do processo H2O2/UV para degradação do corante remazol vermelho RB 133%. 2011. 89 f. Dissertação (Mestrado em Engenharia Civil: Saneamento Ambiental) – Centro de Tecnologia, Universidade Federal do Ceará, Fortaleza, 2011. / Submitted by João silva (jpauloqxb@gmail.com) on 2016-05-13T16:43:02Z No. of bitstreams: 1 2011_dis_jpribeiro.pdf: 1571759 bytes, checksum: 21f017748be8743ca27783d0c7f877b9 (MD5) / Approved for entry into archive by Marlene Sousa (mmarlene@ufc.br) on 2016-05-25T17:02:04Z (GMT) No. of bitstreams: 1 2011_dis_jpribeiro.pdf: 1571759 bytes, checksum: 21f017748be8743ca27783d0c7f877b9 (MD5) / Made available in DSpace on 2016-05-25T17:02:04Z (GMT). No. of bitstreams: 1 2011_dis_jpribeiro.pdf: 1571759 bytes, checksum: 21f017748be8743ca27783d0c7f877b9 (MD5) Previous issue date: 2011-05-25 / Industrial processes that consume excess of water, typically generates a high volume of effluent, where the textile industry is a typical example. The oxidation chemistry is one of the alternative processes for the textile dyes treatment. In this context, the Advanced Oxidation Processes (AOPs) are based on the generation of hydroxyl radicals (.OH) on which are highly oxidizing compounds can decompose quickly and non-selective contaminant solutes, for a partial or complete mineralization. This study investigated the use of advanced oxidation process for degradation of the dye Remazol Red RB 133%. The studies were conducted in two stages. For first step, in the reactor with 710 mL of working volume , were studies the parameters: kinetic effect, hydrogen peroxide dosage, temperature, pH, addition of hydrogen peroxide in the line. The kinetics study decolorization and the inhibitory effect of anions were also studied. The study of kinetic showed that in 250 minutes there was a complete decolorization of the solution using a H2O2 dose of 1% (v/v) through the use of UV radiation, and a 78.41% removal in Chemical Oxygen Demand (COD) was observed. The pH effect not influenced in the decolorization process; however has been influenced in removal of COD. The study of temperature effect showed that for an increase in temperature the decolorization rate increases, but a small improvement in the efficiency of COD removal. The addition of H2O2 during the process increased the efficiency of COD removal. The results of the efficiencies of the end of the process indicated that there was no difference between treatments in the presence of anions in the studied concentration (10 mM) when compared to degradation without the presence of these anions, since the end of all treatments, the solution was colorless. In the second stage, was carried in the reactor with 520 mL of working volume flow studies were performed and power of UV radiation. The studies of flow rate showed that for flow rate of 1.0; 2.0 and 3.0 L/min there was no significant difference in the process decolorization process. The of organic matter concentrations at 480 minutes of experiment for the three flow rates were 36.63%, 51.08% and 48.35% respectively. The increased power of UV radiation caused an increase in the XII efficiency of discolouration and degradation of organic matter. The study showed a real effluent with low efficiency to reduce color and chemical oxygen demand. / As atividades industriais que consomem excesso de água no seu processo industrial, geralmente geram um elevado volume de efluentes, onde a indústria têxtil é um exemplo típico. A oxidação química é um dos processos alternativos para o tratamento de efluentes contendo corantes têxteis, entre eles destacam-se os POAs que são baseados na geração de radicais hidroxilas (.OH) no qual são altamente oxidantes, podendo decompor compostos de maneira rápida e não-seletiva, conduzindo a mineralização parcial ou completa do contaminante. O presente trabalho estudou o uso de processo oxidativo avançado para a degradação do corante Remazol Vermelho RB 133%. Os estudos foram realizados em duas etapas. Na primeira etapa, no reator com 710 mL de volume útil, foram realizados estudos de otimização dos parâmetros: cinética de descoloração, dosagem do peróxido de hidrogênio, pH, temperatura, adição de peróxido de hidrogênio em linha. A cinética de descoloração, e o efeito inibitório de ânions também foram estudados. O estudo de cinética mostrou que em 250 minutos houve uma descoloração completa da solução usando uma dosagem de peróxido de hidrogênio de 1% H2O2 mediante o uso da radiação UV. Nestas condições houve uma remoção de 78,41% na DQO. O pH não influenciou no processo de descoloração da solução, em contraste, para valores de pH iniciais 8 e 10 houve uma maior remoção na DQO. O estudo do efeito da temperatura do sistema mostrou que com o aumento temperatura a velocidade de descoloração é pouco influenciada, ao passo que o aumento da temperatura (80°C) diminuiu a eficiência do processo de remoção da DQO. A adição de H2O2 em linha do processo aumentou a eficiência na remoção de DQO. Os resultados das eficiências de remoção ao final do processo indicaram que não houve diferença entre os tratamentos na presença dos ânions na concentração estudada (10 mM) quando comparada a degradação sem a presença desses ânions, pois ao final de todos os tratamentos a solução ficou incolor. Na segunda etapa, no reator com 520 mL de volume útil, foram realizados estudos de vazão e potência de radiação UV. O estudo mostrou que para as vazões estudadas 1,0; 2,0 e 3,0 L/min não houve uma X diferença significativa no processo de descoloração. As concentrações da matéria orgânica ao final de 480 minutos de experimento para as três vazões foram 36,63%; 51,08% e 48,35%, respectivamente. O aumento da potência de radiação UV proporcionou um aumento na eficiência do processo de descoloração e degradação da matéria orgânica. O estudo com efluente real mostrou uma baixa eficiência na redução de cor e de demanda química de oxigênio.
297

Integração dos processos de eletroflotação e filtração granular descendente para o tratamento de água de produção de petróleo

Nonato, Thyara Campos Martins January 2017 (has links)
Tese (doutorado) - Universidade Federal de Santa Catarina, Centro Tecnológico, Programa de Pós-Graduação em Engenharia Ambiental, Florianópolis, 2017. / Made available in DSpace on 2017-07-04T04:03:47Z (GMT). No. of bitstreams: 1 346682.pdf: 3020190 bytes, checksum: cbda2a4f3af233416b319b831e62b800 (MD5) Previous issue date: 2017 / Um dos principais problemas enfrentado pela indústria petrolífera está relacionado à quantidade de água de produção gerada durante o processo de extração de petróleo e, consequentemente, a destinação final deste efluente, o qual deve passar por processos de tratamento visando atender as especificações para descarte nos oceanos ou injeção em poços de petróleo. Dessa forma, a presente pesquisa teve como objetivo avaliar a eficiência da integração dos processos de eletroflotação e filtração granular descendente no tratamento de água de produção de petróleo, utilizando para isso um efluente simulado preparado pela mistura de água de torneira, óleo lubrificante e NaCl. Para este fim, primeiramente foram estudados em sistema piloto, os efeitos das variáveis operacionais: taxa de escoamento do efluente, densidade de corrente elétrica e concentração de NaCl para a otimização do processo de eletroflotação e, posteriormente, foi estudada a integração dos processos. O desempenho do sistema piloto foi determinado por meio da redução do teor de óleos e graxas (TOG) do efluente tratado. De acordo com os resultados obtidos, o processo de eletroflotação teve o seu melhor desempenho com uma taxa de escoamento do efluente de 62,0 m3m-2d-1, densidade de corrente elétrica de 80,0 A m-2 e concentração de NaCl de 7900 mg L-1. Nessas condições, o processo de eletroflotação apresentou uma redução do TOG inicial (361,88 mg L-1) de mais de 94 % (20,15 mg L-1) após 180 min de eletrólise. Com a integração dos processos estudados, obteve-se uma redução média do TOG do efluente de mais de 98 % (6,42 mg L-1) ao longo de 12 h de tratamento, com um consumo energético do reator eletroquímico de 1,47 kWh m-3. Os processos integrados demonstraram ser também eficientes na redução de outros poluentes do efluente, além do TOG. Foram reduzidos 99,88 % de turbidez, 99,12 % de cor aparente, 90 % da absorbância no UV a 254 nm e 40 % de carbono orgânico dissolvido. Esses resultados demonstram a eficiência da integração dos processos de eletroflotação e filtração granular descendente na redução do TOG do efluente estudado a níveis aceitáveis pelo Conselho Nacional do Meio Ambiente (CONAMA) (< 29 mg L-1) e encorajam a aplicabilidade dessa tecnologia como um processo de tratamento para a indústria petroquímica.<br> / Abstract : One of the main problems faced by the oil industry is related to the amount of produced water generated during the oil extraction process and, consequently, the final destination of this effluent, which must undergo treatment processes in order to meet the specifications for disposal in the oceans or injection into oil wells. Thus, the present research had as objective to evaluate the efficiency of the integration of the processes of electroflotation and down-flow granular filtration in the treatment of water of petroleum production, using a simulated effluent prepared by the mixture of tap water, lubricating oil and NaCl. For this purpose, the effects of the operational variables: effluent flow rate, electric current density and NaCl concentration for the optimization of the electroflotation process were first studied in a pilot system, and the integration of the processes was studied later. The performance of the pilot system was determined by reducing the oils and grease content (OG) of the treated effluent. According to the results obtained, the electroflotation process had its best performance with an effluent flow rate of 62.0 m3m-2d-1, electric current density of 80.0 A m-2 and NaCl concentration of 7900 mg L-1. Under these conditions, the electroflotation process showed a reduction of the initial OG (361.88 mg L-1) of more than 94 % (20.15 mg L-1) after 180 min of electrolysis. With the integration of the studied processes, a mean reduction of the OG of the effluent of more than 98 % (6.42 mg L-1) was achieved over a 12 hour treatment, with an energy consumption of the electrochemical reactor of 1.47 kwh m-3. The integrated processes have also been shown to be efficient in reducing other effluent pollutants besides OG. 99.88 % turbidity, 99.12 % apparent color, 90 % UV absorbance at 254 nm and 40 % dissolved organic carbon was reduced. These results demonstrate the efficiency of the integration of the processes of electroflotation and descending granular filtration in reducing the OG of the studied effluent to levels acceptable to the national council of the environment (CONAMA) (< 29 mg L-1) and encourage the applicability of this technology as a process for the petrochemical industry.
298

Susceptibilidade antimicrobiana em isolados bacterianos de amostras de água do sistema de abastecimento de água e dos efluentes líquidos em hospitais do Vale dos Sinos / Antimicrobial susceptibility in bacterial isolates of water samples from drinking water distribution system and liquid effluents at hospitals of the Sinos Valley

Matos, Julyana Sthéfanie Simões January 2017 (has links)
A disseminação das infecções associadas aos cuidados da saúde é complexa e multifatorial. Neste sentido, a abordagem da participação do ambiente na disseminação de bactérias, avaliando-se os efluentes líquidos, visa contribuir para melhor compreensão e definição das recomendações e políticas de controle dentro dos estabelecimentos de saúde. O objetivo deste trabalho foi avaliar a presença de bactérias E. coli, Pseudomonas sp., Klebsiella sp. e Staphylococcus sp. na água proveniente do Sistema de Abastecimento de Água (SAA) que chega aos hospitais localizados em um município da região do Vale dos Sinos e nos seus respectivos efluentes líquidos bem como a pesquisa dos genes blaSHV, blaTEM e blaCTX-M nos isolados encontrados no efluente. Os isolados foram triados por testes bioquímicos convencionais e posteriormente tiveram sua identificação confirmatória pela metodologia Maldi – TOF. A detecção dos genes blaSHV, blaTEM e blaCTX-M foi realizada nos isolados de E. coli, Pseudomonas sp. e Klebsiella sp. Obtiveram-se, nos efluentes pesquisados, 100 isolados. Destes isolados, 20/100 (20%) foram do gênero Klebsiella sp., 09/100 (9%) do gênero Staphylococcus sp., 05/100 (5%) do gênero Pseudomonas sp. e 09/100 (9%) foram E. coli. Evidenciou-se perfil de multirresistência em 70% dos isolados de E. coli, 41,66% dos isolados de K. variicola, 66,66% dos isolados de K. pneumoniae e 75% dos isolados de Pseudomonas sp. De 30 isolados avaliados para genes de resistência, quatro (04/30) apresentaram o gene blaSHV, três (03/30) apresentaram os genes blaSHV e blaTEM, seis (06/30) apresentaram o gene blaCTX-M e um isolado (01/30) apresentou os genes blaSHV e blaCTX-M. Na água do SAA foi encontrado um isolado do gênero Staphylococcus sp. sensível a todos os antimicrobianos testados. Nos efluentes dos pontos avaliados ocorreu a presença das bactérias potencialmente patogênicas e dos genes de resistência pesquisados. Portanto, este corpo d’água pode estar atuando na disseminação de fatores de resistência. / The spread of infections associated with health care is complex and multifactorial. In this sense, to approach the role of the environment in the bacterial dissemination, evaluating liquid effluents, aims to contribute to a better understanding and definition of recommendations and control policies within health facilities. The aims of this study was to evaluate the presence of E. coli, Pseudomonas sp., Klebsiella sp. and Staphylococcus sp. in the water samples from the Water Distribution System (WDS) that enter the hospitals located in a municipality in the Sinos Valley region and in their respective liquid effluents, as well as the blaSHV, blaTEM and blaCTX-M resistance genes in the effluent isolates. The isolates were screened by conventional biochemical tests and later confirmed by the Maldi - TOF methodology. Detection of the blaSHV, blaTEM and blaCTX-M genes was performed in E. coli, Pseudomonas sp. and Klebsiella sp. A hundred isolates were obtained at the effluents samples surveyed. Of these isolates, 20% were Klebsiella sp., 9% were Staphylococcus sp., 5% were Pseudomonas sp. and 9% were E. coli. A multidrug resistance profile was found in 70% of the E. coli isolates, 41.66% of the K. variicola isolates, 66.66% of the K. pneumoniae isolates and 75% of the Pseudomonas sp. isolates. In the 30 isolates evaluated for the resistance genes, four had the blaSHV gene, three had the blaSHV and blaTEM genes, six had the blaCTX-M gene and one isolate presented the blaSHV and blaCTX-M genes. In the WDS water, a Staphylococcus sp. was found and it was sensitive to all tested antimicrobials. At the effluent from the evaluated points, the presence of potencial patogenic bacteria and the resistance genes studied were observed. Therefore, it might be taking part in the dissemination of resistant factors in this environment.
299

Avaliação do reúso agrícola na adequação de efluentes domésticos urbanos aos padrões da resolução 357/05 do CONAMA: esudo de caso da cidade de Sto. Antônio - BA

Medeiros Netto, Rogério de 15 March 2011 (has links)
Submitted by LIVIA FREITAS (livia.freitas@ufba.br) on 2015-12-04T15:06:36Z No. of bitstreams: 1 Disertação MEAU Rogério de Medeiros Netto.pdf: 36176323 bytes, checksum: 9e35834fd5bb96e036a09daf7cc53bdb (MD5) / Approved for entry into archive by LIVIA FREITAS (livia.freitas@ufba.br) on 2016-01-11T19:00:44Z (GMT) No. of bitstreams: 1 Disertação MEAU Rogério de Medeiros Netto.pdf: 36176323 bytes, checksum: 9e35834fd5bb96e036a09daf7cc53bdb (MD5) / Made available in DSpace on 2016-01-11T19:00:44Z (GMT). No. of bitstreams: 1 Disertação MEAU Rogério de Medeiros Netto.pdf: 36176323 bytes, checksum: 9e35834fd5bb96e036a09daf7cc53bdb (MD5) / Os crescentes problemas de escassez dos recursos hídricos, provocados pelo aumento da demanda em virtude do crescimento populacional e o comprometimento dos mananciais devido ao lançamento de esgotos, levaram a que o reúso da água voltasse a ser considerado. Outro fator que contribuiu para o desenvolvimento das práticas de reúso foi o maior rigor das legislações ambientais em relação ao padrão de qualidade dos efluentes. O estado da Bahia tem cerca de 70% de sua área incluída na região semiárida, onde habita, aproximadamente, a metade da população, sendo que pouco mais da metade em áreas urbanas. As condições climáticas e geológicas do semiárido fazem com que a maioria dos rios seja intermitente, os quais se caracterizam por não ter vazão nos períodos de estiagem, o que requer um nível alto de tratamento para que não haja poluição dos rios. Quanto maior o nível do tratamento, maiores são os custos, o que inviabiliza a adoção em grande escala. Os estudos tiveram por objetivo avaliar a eficiência do reúso agrícola, associado a um sistema de tratamento simplificado e de baixo custo de implantação e operação, como estratégia de redução da poluição de rios localizados em regiões semiáridas. Para tanto, implantou-se um sistema de tratamento simplificado, composto por um conjunto fossa-filtro, na cidade de Sto. Antônio,situada na região nordeste do estado da Bahia a 250 Km de Salvador e sede de um dos distritos do município de São Domingos. O efluente do sistema de tratamento foi aplicado num sistema de irrigação, composto de 8 sulcos com 30m de extensão. Embaixo da linha de plantio foram instalados drenos, a 0,6m e a 1,2m de profundidade para captar efluente infiltrado no solo e submetê-lo a análise laboratorial. Como não houve retenção de efluente nos drenos, procedeu-se a análise do solo para verificar eventuais alterações devido ao lançamento de efluentes. Os parâmetros analisados foram Matéria Orgânica. Fósforo Total e Nitrogênio Amoniacal. Os resultados indicam que o sistema solo-planta foi capaz de remover a matéria orgânica, bem como o Nitrogênio Amoniacal e o Fósforo. A remoção dos parâmetros analisados indica que o reúso agrícola pode ser uma ferramenta a ser utilizada na Gestão dos Recursos Hídricos, sobretudo em regiões semiáridas. As análises de Condutividade Elétrica e de Sólidos Dissolvidos no efluente tratado indicaram que o efluente tem um potencial elevado de provocar salinização no solo.
300

A interferência de diferentes níveis de radiação solar no tratamento de esgoto sanitário em lagoas de alta taxa

ALVES, Luna Gripp Simões January 2012 (has links)
Submitted by Teresa Cristina Rosenhayme (teresa.rosenhayme@cprm.gov.br) on 2015-02-25T13:43:17Z No. of bitstreams: 1 Dissertacao Luna .pdf: 1413009 bytes, checksum: 9a836f2438a7905278719c4f5729b62b (MD5) / Approved for entry into archive by Roberta Silva (roberta.silva@cprm.gov.br) on 2015-07-06T12:17:24Z (GMT) No. of bitstreams: 1 Dissertacao Luna .pdf: 1413009 bytes, checksum: 9a836f2438a7905278719c4f5729b62b (MD5) / Approved for entry into archive by Roberta Silva (roberta.silva@cprm.gov.br) on 2015-07-06T12:17:55Z (GMT) No. of bitstreams: 1 Dissertacao Luna .pdf: 1413009 bytes, checksum: 9a836f2438a7905278719c4f5729b62b (MD5) / Made available in DSpace on 2015-07-06T12:33:09Z (GMT). No. of bitstreams: 1 Dissertacao Luna .pdf: 1413009 bytes, checksum: 9a836f2438a7905278719c4f5729b62b (MD5) Previous issue date: 2012

Page generated in 0.0567 seconds