Spelling suggestions: "subject:"residual""
271 |
Operação de reatores com atividade anammox visando remoção de altas cargas de nitrogênioCasagrande, Caroline Golin 26 October 2012 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico, Programa de Pós-Graduação em Engenharia Química, Florianópolis, 2011 / Made available in DSpace on 2012-10-26T05:46:32Z (GMT). No. of bitstreams: 0 / Na suinocultura, a elevada carga de nutrientes, somada ao grande volume de dejetos, são os maiores desafios de manejo da atividade. Na maioria dos casos, a falta de áreas cultiváveis para disposição do efluente no solo exige o uso de técnicas de tratamento com capacidade de remoção de elevadas cargas de nutrientes. Nesse cenário surge o processo ANAMMOX, precedido por um sistema de nitritação parcial. O objetivo desse trabalho foi otimizar a operação de reatores com diferentes configurações com atividade ANAMMOX realizando progressão de carga por diferentes condições operacionais. Três reatores, denominados reator A, B e C, foram inoculados e partidos, em fluxo ascendente, temperatura controlada em 35 oC, concentração de OD inferior a 0,2 mg.L-1, com biomassa em suspensão, utilizado como inóculo biomassa com atividade ANAMMOX estável proveniente de um reator piloto, em diferentes concentrações. O tempo de partida do reator A, inoculado com 1 % de biomassa (v/v) foi de aproximadamente 100 dias, e dos reatores B e C, inoculados com 30 % de biomassa (v/v) foi de aproximadamente 60 dias, mostrando que é possível dar partida a reatores com baixa concentração de inóculo e que maiores
concentrações reduzem significativamente o tempo de partida do sistema. Para comprovar a veracidade do processo ANAMMOX nos reatores acompanhou-se o comportamento das formas nitrogenadas, calculou-se os coeficientes estequiométricos (que ficaram próximos aos encontrados na literatura) e realizou-se análises de FISH com sonda específica (AMX 368) (com resultados positivos). Através de estudo cinético determinou-se as velocidades específicas de consumo de amônio e nitrito e produção de nitrato, que foram: µN-NH3 = 47,94 mgNNH3. gSSV-1.d-1; µN-NO2 = 59,39 mgN-NO2 -.gSSV-1.d-1 e µN-NO3 = 14,75 mgN-NO3 -.gSSV-1.d-1. Em relação à progressão de carga o processo se mostrou mais sensível ao aumento da concentração que as reduções de TRH, a máxima carga removida pelo reator A, que operou com aumento de concentração, foi 1,53 KgN.m-3.d-1, aos 331 dias de operação, sendo alimentado com 560 mgN.L-1.d-1 e com TRH de 6h, e pelo reator C, que operou com redução do TRH, foi 16,24 KgN.m-3.d-1, aos 193 dias de operação sendo alimentado com 200 mgN.L-1.d-1 e com TRH de 0,2h. / In the swine production, the high nutrient load, coupled with the large volume of wastewater, are the biggest challenges of management activity. Generally, the lack of arable land for disposal of effluent on the ground requires the use of treatment techniques capable of removing high loads of nutrients. There are numerous alternatives for nitrogen removal from wastewater, including anammox process preceded by a system of partial nitritation. The aim of this study was to optimize the operation of anammox reactors with different configurations and perform cargo progression through different operating conditions. Three reactors, called A, B and C, were inoculated and started, in upward flow, temperature controlled at 35 ° C, DO concentration below 0.2 mg L-1, with suspended biomass and used as inoculum biomass with stable anammox activity from a pilot reactor at different concentrations. The starting time of the reactor, inoculated with 1% biomass (v / v) was approximately 100 days, and the reactors B and C, inoculated with 30% biomass (v / v) was approximately 60 days, showing it is possible to start the reactors with low inoculum concentration and higher
concentrations significantly reduce the start up time of the system. To prove the veracity of the anammox process in the reactors was monitored the behavior of nitrogen forms, we calculated the stoichiometric coefficients (which were close to those found in literature) and was carried of the FISH analysis with specific probe (AMX 368) (with results positive). Through the kinetic study was determined the specific consumption rates of ammonium and nitrite and nitrate production, which were µN-NH3=47,94mgN-NH3.gSSV-1.d-1; µN-NO2 = 59,39 mgN-NO2 -.gSSV-1.d-1 e µN-NO3 = 14,75 mgN-NO3 -.gSSV-1.d-1. the process was more sensitive to the increased nitrogen concentration that reductions in HRT, the maximum load removed by the reactor A, which operated with increasing concentration was 1.53 KgN.m-3.d-1, to 331 days of operation, being fed 560 mgN.L-1.d-1 and HRT of 6h, and in the reactor C, which operated with reduced HRT was 16.24 KgN.m-3.d-1, to 193 days of operation being fed 200 mgN.L-1.d-1 and HRT of 0.2 h.
|
272 |
Recuperação da amônia removida por processo de air stripping aplicado ao tratamento de lixiviados de aterro sanitárioSantos, Heloísa Alves Pereira dos January 2011 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico, Programa de Pós-Graduação em Engenharia Ambiental, Florianópolis, 2011 / Made available in DSpace on 2012-10-26T08:21:55Z (GMT). No. of bitstreams: 1
295148.pdf: 2267799 bytes, checksum: 9e13a4d305b5dcdb4f58ed362621c68f (MD5) / Altas concentrações de nitrogênio amoniacal presente nos lixiviados de aterro sanitário podem causar impactos ambientais e à saúde pública. O objetivo deste trabalho foi a remoção de amônia de lixiviado de aterro sanitário pelo processo de air stripping (arraste com ar) e sua recuperação através de absorção em solução ácida. Para issoq foi utilizada uma torre de PVC com 150 mm de diâmetro e 1,95 m de altura útil recheada com anéis tipo "raschig" de 5 cm de comprimento e 2,5 cm de diâmetro. As vazões de lixiviado testadas foram de 9, 18, 20 e 40 L/h, e as vazões de ar foram de 1.800 e 3.600 L/h. As relações entre vazão de ar e vazão de lixiviado foram de 200, 90 e 45. Também foram testados alguns produtos químicos para promover a alcalinização do lixiviado antes do processo de air stripping: hidróxido de cálcio padrão analítico; cal hidratada comercial tipo CHIII e hidróxido de sódio padrão analítico. Para recuperar a amônia foram usados 3 frascos lavadores, de vidro, contendo 2,5 L de solução de ácido fosfórico, com concentrações de 0,12 e 0,24 mol/L. Para as condições avaliadas neste trabalho, foram necessários de 9 a 21 m3 ar para cada grama de nitrogênio amoniacal removido. Os resultados mostraram que é possível remover todo o nitrogênio amoniacal do lixiviado usando air stripping. Além disso, a amônia pode ser recuperada em até 92% utilizando ácido fosfórico, gerando-se assim o fosfato de amônio.
|
273 |
Tratamento de lodo anaeróbio em wetlands construídos operados em alta taxa e com a recirculação de líquido percoladoKäfer, Silvana Cristina January 2015 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico, Programa de Pós-Graduação em Engenharia Ambiental, Florianópolis, 2015. / Made available in DSpace on 2015-11-10T03:09:38Z (GMT). No. of bitstreams: 1
335892.pdf: 2614464 bytes, checksum: e3f36fdce4f48c36ee61e16826889421 (MD5)
Previous issue date: 2015 / Com o objetivo de avaliar a eficiência dos wetlands construídos para o tratamento de lodo (WCL) foi realizada a operação e monitoramento de um experimento com dois wetlands piloto: um plantado com Cyperus papyrus (WP) e outro com Typha domingensis (WT). O tratamento foi baseado nos processos de desaguamento e estabilização de lodo proveniente de um tanque séptico. Os WCL foram operados com a aplicação de alta taxa de alimentação, intercalada com a recirculação do líquido percolado na própria unidade. A operação e monitoramento foram divididos em duas fases. Na Fase 1 (Outubro a Dezembro/2013) foram avaliadas as características físico-químicas do lodo do tanque séptico, do líquido percolado 1 (LP1) de cada wetland, bem como do líquido percolado 2 (proveniente da recirculação do LP1). Na Fase 2 (Janeiro a Novembro/2014), a alimentação dos WCL foi cessada e o lodo acumulado permaneceu em repouso durante onze meses. Amostras do lodo acumulado foram coletadas e foram analisados parâmetros físico-químicos, microbiológicos e seu potencial agronômico (este último ao final da Fase 2). De acordo com os resultados o teor de água do lodo foi reduzido, em média, 80% durante o desaguamento na Fase 1. Entre os parâmetros monitorados no LP1 destacam-se a remoção de 99% da carga de DQO e sólidos e de 96 e 97% da carga de amônia em WT e WP, respectivamente. Quanto à recirculação, WT e WP alcançaram, em média, 71 e 33% de remoção de água no LP1, e ainda tiveram um bom percentual de redução da carga poluidora, destacando-se 80% de remoção da carga de DQO e fósforo e 72% de remoção da carga de amônia em WT. Em WP houve remoção de 64% da carga de fósforo e de 31% na carga de amônia. Verificou-se que a maior redução das frações voláteis se deu durante o desaguamento do lodo (22% em média), enquanto nos onze meses de repouso houve redução de apenas 5 e 9% para WT e WP. As concentrações de compostos inorgânicos no lodo acumulado foram pequenas e estavam bem abaixo do limite máximo permitido pela Resolução CONAMA 375/2006. Houve, também, uma redução significativa quanto aos indicadores/patógenos, sendo que Salmonella e Adenovírus estavam ausentes em todas as amostras, e a concentração de E.coli foi < 10² NMP. g-1. O teor de matéria orgânica encontrado no lodo acumulado foi de 17%, superior ao que preconiza a Instrução Normativa do Ministério da Agricultura, Pecuária e Abastecimento Nº 25 de 2009. O teor de nitrogênio total encontrado no lodo acumulado no final do experimento foi quase o triplo do que o mínimo recomendado pela Instrução. Os teores de NPK do lodo acumulado foram de 1,83/1,25/0,02%. Os WCL associados às condições climáticas locais proporcionaram, portanto, um tratamento efetivo do lodo e de seus subprodutos.<br> / Abstract : In order to evaluate the efficiency of constructed wetlands for sludge treatment (WCL) two pilot wetlands were operated: one with Cyperus papyrus (WP) and the other with Typha domingensis (WT). The treatment was based on dewatering and stabilizing the sludge from a septic tank. The WCL were operated at high feeding rate, alternating with recirculation of the leachate liquid. The operation and monitoring of the system was divided in two phases. In Phase 1 (from October to December/2013) the physicochemical characteristics of the sludge from the septic tank, the leachate liquid (LP1) of each wetland, and the leachate liquid 2 (from the recirculation of LP1) were evaluated. In Phase 2 (from January to November/2014), the feeding of the WCL was stopped and the accumulated sludge was at a standstill for eleven months. Samples of the accumulated sludge were collected and analyzed for physical, chemical, and microbiological parameters as well as for the agronomic potential (the latter at the end of Phase 2). The results showed that the sludge water content was reduced by around 80% during the dewatering in Phase 1. Among the monitored parameters in LP1, the removal of 99% for COD and solids loads; and of 96 and 97% for ammonia load in WT and WP, respectively, can be highlighted. Regarding the recirculation, the average water removal in LP1 reached 71 and 33% for WT and WP, respectively. Furthermore, the systems were able to reduce the polluting load, with removal of 80% for COD and phosphorus, and of 72% for ammonia in WT. In WP 64% of the phosphorus load and 31% of the ammonia load were removed. It was found that further reduction of volatile fractions occurred during sludge dewatering (22% on average); while during the eleven months of standstill period the reduction was only of 5 and 9% for WT and WP, respectively. The concentrations of inorganic compounds in the accumulated sludge were small and below the maximum values permitted by the Resolution 375/2006 of CONAMA. A significant reduction of pathogens was also observed. Salmonella and Adenovirus were absent in all samples, and the concentration of E. coli was of <10² NMP.g-1. The organic matter content found in the accumulated sludge was of 17%. This value is higher than the limit permitted by the Ministry of Agriculture Normative Instruction, Livestock, and Food Supply nº 25/2009. The total nitrogen content found in the accumulated sludge at the end of the experiment was almost the triple than the minimum recommended by the aforementioned Instruction. NPK rates of the accumulated sludge were 1.83 / 1.25 / 0.02%. The WCL associated to local climatic conditions were, therefore, an effective treatment of sludge and its by-products.
|
274 |
Uso da casca do fruto de Cereus hildmannianus no tratamento de águas residuáriasGilioli, Andressa January 2015 (has links)
Tese (doutorado) - Universidade Federal de Santa Catarina, Centro Tecnológico, Programa de Pós-Graduação em Engenharia Química, Florianópolis, 2015. / Made available in DSpace on 2015-11-17T03:06:28Z (GMT). No. of bitstreams: 1
336049.pdf: 1439360 bytes, checksum: 83074ed34cf38796c02683060cb2b8ad (MD5)
Previous issue date: 2015 / Alguns biomateriais naturais provenientes de produtos ou subprodutos agrícolas têm sido explorados como novas fontes de adsorventes nos últimos anos, particularmente devido ao seu baixo custo. Recentemente uma patente foi desenvolvida, no laboratório em que este trabalho foi desenvolvido, para utilização do fruto doCereus hildmannianus K. Schum, uma espécie de cactus que ocorre naturalmente em regiões áridas do Brasil, para obtenção de suco,o que pode vir a gerar quantidades significativas de resíduos, que por sua vez podem ter uso no tratamento de efluentes. O presente trabalho tem como objetivo caracterizar e avaliar a viabilidade de o uso da casca do fruto de Cereus hildmannianus K. Schum como adsorvente Após lavagem, a casca do fruto foi seca e moída. Esse material foi modificado quimicamente por hidrólise, esterificação e metilação visando aumentar a sua capacidade de adsorção. Os diferentes adsorventes foram caracterizados por análises físico-químicas como ponto de carga zero, grupos funcionais de superfície, porosidade e área superficial. Os resultados indicaram que a adsorção do corante azul de metileno pela biomassa e pelos adsorventes modificados quimicamente é um processo de adsorção física que ocorre rapidamente, entre 30 e 120 min, segundo uma cinética de pseudo-segunda ordem. Quanto às isotermas de adsorção, os diferentes adsorventes foram descritos por diferentes modelos: a biomassa bruta pelo modelo de Temkin, a biomassa hidrolisada e metilada pelo modelo de Freundlich, enquanto que a biomassa esterificada pelo modelo de Langmuir. A metilação aumentou a adsorção do corante em 137% (4,6 mg·g-1), 44,33% com a biomassahidrolisada (2,8 mg·g-1) e 75,25% com aesterificada (3,4 mg·g-1) em relação a biomassa bruta. Os testes de adsorção de proteinas foram desenvolvidos utilizando a biomassa bruta e a proteína BSA (Albumina de soro bovino), sendo que os resultados encontrados caracterizam a adsorção do BSA como um processo químico, com lenta cinética da reação (24 horas).A capacidade de adsorçãoda casca de Cereushildmannianusvariou de 360,5 a 554,5mg·g-1 paraas trêsconcentrações iniciaisavaliadas.Um modelo de pseudo-segunda ordem descreveu a cinética de adsorção do BSA,enquanto que as isotermas de adsorçãode equilíbrioforam descritasde forma satisfatóriapelo modelo deLangmuir. Os resultados encontrados neste trabalho mostram que os adsorventes obtidos de Cereus hildmannianus podem ser utilizado no tratamento de efluentes, principalmente na adsorção de proteína, onde foram obtidas as maiores capacidades de adsorção.<br> / Abstract : Some natural biomaterials derived from agricultural products or byproducts have been explored as new adsorbents sources in the recent years, particularly due to its low cost. Recently a patent was developed to use the Cereus hildmannianus K. Schum fruit, a cactus species that occurs naturally in arid regions of Brazil. The object of this patent is the obtaining of mucilage juice, which, after process, can generate a significant amount of waste. In turn, the residue can be used in wastewater treatment. The present work aims to study the adsorption capacity of theCereus hildmannianus K. Schum fruit peel of dyes and proteins for use in effluents from textile and food industry. After washing, the fruit peel was dried and ground. This material was chemically modified by hydrolysis, esterification and methylation to increase the adsorption capacity of methylene blue dye. The results showed that the adsorption of methylene blue dye by the biomass and modified adsorbents is a physical adsorption process that occurs quickly, between 30 and 120 minutes, according to a pseudo-second order kinetic. As for the adsorption isotherms, different models were adjusted to the distinct systems. The Temkin modelwas adjusted tothe gross biomass, the Freundlich model to the hydrolyzed and methylated biomass, while the Langmuir model was fitted on the esterified biomass data. Methylation increased thedye adsorption in 137% (4.6 mg·g-1), hydrolyzed biomass in 44,33% (2.8 mg·g-1) and esterified in 75,25% (3,4 mg·g-1 ) compared to gross biomass. Protein adsorption tests have been made by gross biomass on model protein (BSA), and initial results characterize the BSA adsorption as a chemical process with slow reaction kinetics (24 hours). The adsorption capacity of the Cereus hildmannianuspeel ranged from 360,5 to 554,5 mg·g-1 for the three initial concentrations evaluated. The adsorption kinetics of BSA followed a pseudo- second order model and the isotherms were described satisfactorily by the Langmuir model. The results of this study show that the adsorbents obtained with the Cereus hildmannianusK. Schum peel may be used in the treatment of effluents, particularly in protein adsorption where the largest adsorption capacities were obtained.
|
275 |
Modificação química da casca do coco bruto (Cocos Nucifera) para remoção de Cu(II) de efluente sintético e industrial: estudo de isoterma de adsorção, cinética e coluna de leito fixo / Chemical modification of bark gross coco (Cocos Nucifera) removal of Cu (II) and synthetic industrial effluent from: study of adsorption isotherm, kinetic and fixed bed columnSousa Neto, Vicente de Oliveira 31 October 2012 (has links)
SOUSA NETO, V. O. Modificação química da casca do coco bruto (Cocos Nucifera) para remoção de Cu(II) de efluente sintético e industrial: estudo de isoterma de adsorção, cinética e coluna de leito fixo. 2012. 161 f. Tese (Doutorado em Engenharia Hidráulica e Ambiental) - Centro de Tecnologia, Universidade Federal do Ceará, Fortaleza, 2012. / Submitted by Marlene Sousa (mmarlene@ufc.br) on 2013-01-18T12:26:33Z
No. of bitstreams: 1
2012_tese_vosousaneto.pdf: 2941102 bytes, checksum: ef6d6e13bf21e894b11095413a9b8923 (MD5) / Approved for entry into archive by Marlene Sousa(mmarlene@ufc.br) on 2013-02-08T17:57:00Z (GMT) No. of bitstreams: 1
2012_tese_vosousaneto.pdf: 2941102 bytes, checksum: ef6d6e13bf21e894b11095413a9b8923 (MD5) / Made available in DSpace on 2013-02-08T17:57:00Z (GMT). No. of bitstreams: 1
2012_tese_vosousaneto.pdf: 2941102 bytes, checksum: ef6d6e13bf21e894b11095413a9b8923 (MD5)
Previous issue date: 2012-10-31 / The heavy metals are known to be highly toxic at very low concentrations in water. At this point, numerous studies have been dedicated to their removal to acceptable limits of an environmental point of view. Such researches are focused mainly in developing an efficient removal and low cost. Many methods have been proposed for removing heavy metals, for example, precipitation, membrane filtration, ion exchange and adsorption. The precipitation is one method that has been used more although an inappropriate method regarding the environmental impact for generating residues. The bagasse, coconut offers natural facility to be found and handled, so it is one of the most studied materials for reuse. This paper aims to make a study of adsorption of Cu 2+ using bagasse as adsorbent modified coconut. The modifications were employed (a) by polymerization of formaldehyde in sulfuric acid medium, b) treatment with ionic líguido c) Esterification acid and multicarboxílicos multifenólicos. The models applied to the study of isotherms were Langmuir, Freundlich, Temkin and Dubinin-Raduschevich. Applying the model in the study of Langmuir Adsorption of Cu (II) adsorbent modified BCFB the maximum adsorption capacity qm and kL were contained 125 mg.g-1 and 1.11 x10-2L.mg for Cu +2. For adsorbentes BC / LI and BCTânico the qm value were 64.5 and 99mg.g-1 respectively as kL value were 5.3 x10-2 5.6 x10-2 respectively. The kinetic model that best fit the phenomenon was the second order. The results showed that the coconut coir chemically modified is a potential adsorbent for removing Cu2+. The study column was used to verify the performace of the adsorbent when employing industrial effluent. Under the conditions employed in this study was modified with tannic acid that had shown the best removal performance desempenho removal. Also the reusability of the adsorbent is remarkable since it promotes a lowering cost, considering its applicability on an industrial scale. / Os metais pesados são conhecidos por serem altamente tóxicos em baixíssimas concentrações na água. Sendo assim, numerosos estudos tem sido dedicados à sua remoção a limites aceitáveis do ponto de vista ambiental. Tais pesquisas se concentram, principalmente, no desenvolvimento de uma remoção eficiente e de baixo custo. Muitos métodos têm sido propostos para remoção de metais pesados, por exemplo, precipitação, membranas filtrantes, troca iônica e adsorção. A precipitação é um dos métodos que mais vem sendo utilizado embora seja um método inadequado no que se refere a impactos ambientais por gerar resíduos. A casca de coco oferece facilidade natural de ser encontrado e manejado, por isso é um dos materiais mais estudados para fins de reaproveitamento. Este trabalho se propõe a fazer um estudo de adsorção de Cu+2 utilizando casca de coco modificado como adsorbente. As modificações empregadas foram (a) por polimerização do formaldeído em meio sulfúrico; b) Tratamento com líquido iônico e c) Esterificação por ácido multicarboxílicos e multifenólicos. Os modelos aplicados para o estudo de isotermas foram de Langmuir, Freundlich, Temkin e Dubinin –Raduschevich. Aplicando o modelo de Langmuir no estudo de adsorção de Cu(II) no adsorbente modificado BCFB a capacidade máxima de adsorção qm e a constante KL foram 125 mg/g e 1,11x10-1 L.mg-1 para o Cu+2 . Para os adsorbentes BC/LI e BCTânico o valor de qm foram 64,5 e 99mg.g-1 , respectivamente enquanto o valor de KL foram 5,3x10-2 e 5,6x10-2 , respectivamente . O modelo cinético que melhor se ajustou ao fenômeno foi o de segunda ordem. Os resultados obtidos mostraram que a casca de coco quimicamente modificado é um potencial adsorbente para remoção de Cu+2. O estudo de coluna foi empregado para verificar a desempenho do adsorbente quando se emprega efluente industrial. Nas condições empregadas neste estudo a modificação com ácido tânico foi a que teve melhor desempenho de remoção. Destaca-se também a capacidade de reutilização do adsorbente que promove uma diminuição do custo operacional quando é considerada sua aplicabilidade numa escala industrial.
|
276 |
Remoção de nitrito, nitrato e amônia de efluentes de indústrias petrolíferas através de reatores biológicos inoculados com “Aspergillus niger” / Nitrite removal, nitrate and ammonia from oil industry effluents by biological reactors inoculated with "Aspergillus niger"Freitas Neto, Mário de Alencar January 2005 (has links)
FREITAS NETO, M. A. Remoção de nitrito, nitrato e amônia de efluentes de indústrias petrolíferas através de reatores biológicos inoculados com “Aspergillus niger”. 2005. 92 f. Dissertação (Mestrado em Engenharia Civil: Saneamento Ambiental) – Centro de Tecnologia, Universidade Federal do Ceará, Fortaleza, 2005. / Submitted by João silva (jpauloqxb@gmail.com) on 2016-06-08T18:36:36Z
No. of bitstreams: 1
2005_dis_mafreitasneto.pdf: 845871 bytes, checksum: 3b2dd0932a47a69f308f96fbfcb40ea7 (MD5) / Approved for entry into archive by Marlene Sousa (mmarlene@ufc.br) on 2016-07-25T17:29:30Z (GMT) No. of bitstreams: 1
2005_dis_mafreitasneto.pdf: 845871 bytes, checksum: 3b2dd0932a47a69f308f96fbfcb40ea7 (MD5) / Made available in DSpace on 2016-07-25T17:29:30Z (GMT). No. of bitstreams: 1
2005_dis_mafreitasneto.pdf: 845871 bytes, checksum: 3b2dd0932a47a69f308f96fbfcb40ea7 (MD5)
Previous issue date: 2005 / The purpose of this research was to evaluate the removal of nitrogen compounds found in petroleum industry wastewater, by employing a biologic process with fungi. During 156 days, two aerobic biologic reactors with fungi (BRF), with immobilized biomass and continuous up flow were built and operated. Both reactors were made in acrylic and presented identical dimensions height 60 cm, 10 cm diameter and 4,5 L liquid volume. The first reactor (R1) had polyamide bed as support medium and the second one (R2) used polyurethane foam. Initially, the reactors containing the wastewater were inoculated with 2 x 106 spores.mL-1, of Aspergillus niger AN 400. They remained in rest, with no aeration, for 24 h mycelium growth. After this period, the aeration and recirculation of the effluent started and here mointained for one week. The recirculation was then suspended and it was initiated the reactors feeding with wastewater and the parameters monitoring. The research was divided in four phases, with different HRT and different glucose concentrations (except phase I) as primary source of carbon. In phase I, the reactors were operated for 35 days with 8h HRT and with no addition of primary source of carbon. Good nitrite removal efficiencies were observed, with mean values of 82% and 89%, for R1 and R2, respectively. For nitrate, the mean values were 53% for R1 and 55% for R2. In relation to ammonia, the mean values in effluent concentration were: R1, 10,31 mg N-NH3.L-1 and R2, 10,62 mg N-NH3.L-1, which were higher than the affluent values, with a mean value of 7,87 mg N-NH3.L-1. In phase II, the reactors were operated for 59 days with HRT of 8h and 0,5 g/L of glucose were added to the affluent. The mean values of ammonia removal were 57% for R1 and 51% for R2. Nitrite, values were 82% and 84% for R1 and R2 respectively, nitrate 70% for R1 and 80% for R2. In phase III, the HRT was reduced to 4h and the addition of glucose was sustained. In this phase, the reactors were operated for 38 days. The removal values observed for ammonia were 54% for R1 and 57% and R2. In relation to nitrite, these values were 90% and 76% for R1 and R2 respectively and for nitrate the values were 63% and 62% for R1 and R2. In phase IV, reactors were operated for 24 days, with HRT of 4h and addition of 1,0 g.L-1 of glucose to the affluent. The removal values obtained for ammonia were 48% and 53% for R1 and R2, and for nitrate these values were 76% and 79% for R1 and R2. In relation to nitrite, the mean value of the effluent was 0,04 mg N-NO2.L-1 for both reactors, twice the value of the affluent (0,02 mg N-NO2.L-1). In this research, it was observed an alternation between production and removal of ammonia and nitrite however the reactors when operated in phase II and III showed efficient in the removal of nitrite, nitrate and ammonia present in petroleum industry wastewater. / A proposta desta pesquisa foi avaliar a remoção de compostos nitrogenados presentes em águas residuárias de indústrias petrolíferas, empregando processo biológico com fungos. Foram montados e operados durante 156 dias, em escala de laboratório, dois reatores biológicos aeróbios com fungos (RBF), com biomassa imobilizada e fluxo contínuo ascendente. Os dois reatores eram constituídos de acrílico e apresentavam dimensões idênticas com 60 cm de altura, 10 cm de diâmetro e volume útil de 4,5 L, sendo que o primeiro reator (R1) teve como meio suporte manta agulhada de poliamida, e o segundo reator (R2) espuma de poliuretano. Inicialmente, os reatores contendo a água residuária a ser estudada foram inoculados com 2 x 106 esporos/mL, de Aspergillus niger AN 400, e deixados em repouso, sem aeração por 24h para crescimento do micélio. Após esse período iniciou-se a aeração e a recirculação do efluente dos reatores que foi mantida por uma semana. Em seguida a recirculação foi suspensa, iniciou-se a alimentação dos reatores com a água residuária e os parâmetros de interesse passaram a ser monitorados. A pesquisa foi dividida em 4 fases, nas quais foram aplicados diferentes TDH e concentrações variadas de glicose (exceto fase I) como fonte primária de carbono. Na fase I os reatores foram operados durante 35 dias com TDH de 8h, sem adição de fonte primária de carbono. Foi observada, boa eficiência de remoção de nitrito, com valores médios de 82%, e 89%, para R1 e R2, respectivamente. Para Nitrato as remoções foram de 53% para o R1 e de 55% para o R2. Com relação à amônia, os valores médios das concentrações nos efluentes, foram: R1 igual a 10,31mgN-NH3 /L, e R2 igual a 10,62 mgN-NH3 /L, as quais foram superiores aos de entrada, com valor médio de 7,87 mgN-NH3 /L. Na fase II os reatores foram operados durante 59 dias com TDH de 8h, com adição de 0,5g de glicose/L ao afluente. Os valores médios de remoção de amônia foram iguais a 57% e 51% para R1 e R2 respectivamente, de nitrito foram 82% para R1 e 84% para R2, e para nitrato os valores de remoção foram de 70% para R1 e 80% para R2. Na fase III o TDH foi reduzido para 4h, manteve-se a adição de 0,5g de glicose/L, ao afluente, sendo que os reatores operaram durante 38 dias. Foram observados valores de remoção de amônia de 54%, e 57% para R1 e R2, respectivamente e para nitrito, estes valores foram de 90%, e 76% para R1 e R2 e para nitrato os valores foram de 63% e 62% para R1 e R2. Na fase IV os reatores foram operados durante 24 dias, com TDH de 4h e adição de 1,0g de glicose/L ao afluente. A remoção de amônia foi de 48% e 53% para R1 e R2, nitrato 76% e 79% para R1 e R2. Em relação ao nitrito, o valor médio no efluente foi de 0,04 mgN-NO2 /L para os dois reatores, sendo o dobro do valor do afluente 0,02 mgN-NO2 /L. Nesta pesquisa os reatores R1 e R2, quando operados nas fases II e III, mostraram-se eficientes na remoção de nitrito, nitrato e amônia de efluentes de indústrias petrolíferas.
|
277 |
Efeito da adição de lodo ao inóculo de reator anaeróbio híbrido sólido-líquido tratando fração orgânica de resíduos sólidos urbanos / Slurry addition of the inoculum effect of solid-liquid hybrid anaerobic reactor treating organic fraction of municipal solid wasteCarneiro, Pedro Henrique January 2005 (has links)
CARNEIRO, P. H. Efeito da adição de lodo ao inóculo de reator anaeróbio híbrido sólido-líquido tratando fração orgânica de resíduos sólidos urbanos. 2005. 115 f. Dissertação (Mestrado em Engenharia Civil: Hidráulica e Saneamento) – Escola de Engenharia de São Carlos, Universidade de São Paulo, São Paulo, 2005. / Submitted by João silva (jpauloqxb@gmail.com) on 2016-06-15T19:26:37Z
No. of bitstreams: 1
2005_dis_phcarneiro.pdf: 13382343 bytes, checksum: 17f4952682ce52601f457435aeb2ebeb (MD5) / Approved for entry into archive by Marlene Sousa (mmarlene@ufc.br) on 2016-08-22T11:15:28Z (GMT) No. of bitstreams: 1
2005_dis_phcarneiro.pdf: 13382343 bytes, checksum: 17f4952682ce52601f457435aeb2ebeb (MD5) / Made available in DSpace on 2016-08-22T11:15:28Z (GMT). No. of bitstreams: 1
2005_dis_phcarneiro.pdf: 13382343 bytes, checksum: 17f4952682ce52601f457435aeb2ebeb (MD5)
Previous issue date: 2005 / Treatment of organic solid wastes like wastewater treatment plant sludges and organic
fraction of municipal solid wastes are current issues in environmental engineering.
Biological processes are more appropriate to treat these wastes. Recent trends like Kyoto
protocol and clean development mechanisms (CDM) are improving anaerobic digestion
of organic solid wastes. It was investigated the effect of adding anaerobic sludge to
bioreactor landfill leachate applied like seed in hybrid anaerobic solid-liquid bioreactor
treating organic fraction of municipal solid wastes. It was verified that sludge addition
improved anaerobic digestion, accelerating volatile fatty acids degradation, anticipating
biogas generation, increasing methane percentile composition and promoting more variability
and presence of microorganisms. Sludge addition also increased total solids and
total volatile solids conversion. / O tratamento de resíduos sólidos orgânicos, como lodos de estação de tratamento de
esgotos e a fração orgânica de resíduos sólidos urbanos, são desafios atuais da engenharia
sanitária e ambiental. Os processos biológicos são os mais apropriados para o tratamento
desses resíduos. Acordos recentes como o Protocolo de Kyoto e os mecanismos
de desenvolvimento limpo (MDL) estão contribuindo para o crescimento da digestão
anaeróbia de resíduos sólidos orgânicos em todo o mundo. Nesta pesquisa foi investigado
o efeito da adição de lodo anaeróbio ao lixiviado de aterro sanitário empregado como
inóculo de reator anaeróbio híbrido sólido-líquido tratando a fração orgânica de resíduos
sólidos urbanos. Foi verificado que a adição de lodo melhorou a digestão anaeróbia,
acelerando a degradação de ácidos graxos voláteis, antecipando a geração de biogás,
aumentando a composição percentual de metano e promovendo maior variabilidade e
presença de microrganismos. A adição de lodo também aumentou a eficiência de conversão
de sólidos totais e sólidos totais voláteis.
|
278 |
Oxidação fotoquímica UVC/H2O2 de águas residuárias têxteis visando o reuso no beneficiamento têxtilSalim, Márcia Michele Fialho Farias January 2017 (has links)
Tese (doutorado) - Universidade Federal de Santa Catarina, Centro Tecnológico, Programa de Pós-Graduação em Engenharia Química, Florianópolis, 2017. / Made available in DSpace on 2018-01-30T03:14:44Z (GMT). No. of bitstreams: 1
349695.pdf: 4391269 bytes, checksum: 0286f5e3702cbd861ce7735c8611cff2 (MD5)
Previous issue date: 2017 / Os Processos Oxidativos Avançados (POAs) têm-se destacado nos últimos anos como uma tecnologia alternativa ao tratamento de várias matrizes ambientais, dentre elas, as águas residuárias têxteis. Aplicou-se a oxidação fotoquímica (UVC/H2O2) no tratamento de três águas residuárias têxteis reais, previamente tratadas biologicamente, denominadas de ART-A, ART-B e ART-C. Primeiramente, para a oxidação fotoquímica (UVC/H2O2), um estudo cinético foi realizado para determinar as condições operacionais, tais como a dosagem de peróxido de hidrogênio (0 ? 100 mM), pH da solução (3,0; 5,0; 9,0 e pH natural das águas residuárias: 8,1 (ART-A), 7,7 (ART-B) e 8,3 (ART-C)) e temperatura da solução (15, 23, 35 e 50 ºC). A fotólise do peróxido de hidrogênio sob radiação UVC demonstrou ser uma tecnologia eficiente na remoção de cor das três águas residuárias têxteis reais. O processo UVC/H2O2 aplicado à ART-A e ART-B, respectivamente, resultou em uma remoção de cor de 81% e 68% (método Pt-Co), 83% e 72% (DFZ436nm), 88% e 76% (DFZ525nm) e 86% e 69% (DFZ620nm), utilizando 25 mM de H2O2 e 8,3 e 5,5 kJUVC L-1 em 180 min e 120 min, respectivamente. A água residuária têxtil ? C (ART-C) apresentou parâmetros para remoção de cor, tais como, menor tempo/energia para descoloração, temperatura de saída do reator biológico favorável à descoloração e pH da própria água residuária como melhor resultado para a descoloração. Sendo estes de 90 min/4,1 kJUVC L-1; 35 ºC e 8,31 respectivamente. O processo UVC/H2O2 aplicado à ART-C resultou em uma remoção de cor de 92% (método Pt-Co), 94% (DFZ436nm), 96% (DFZ525nm) e 94% (DFZ620nm). Considerando o lançamento das águas residuárias tratadas em corpos receptores, a biodegradabilidade de ART-A e ART-B, foi avaliada a partir do teste Zahn-Wellens, o qual demonstrou um aumento significativo no percentual de carbono biodegradável ao final do foto-tratamento (62% para ART-A e 45% para ART-B). Por outro lado, com o propósito de reúso no beneficiamento têxtil, ART-C foi utilizada como água de banho durante o processo de tingimento do substrato de algodão e as amostras obtidas resultaram em bons indicadores de qualidade quando comparados ao processo padrão. A percentagem máxima de águas residuárias têxteis tratadas por oxidação fotoquímica que podem ser reutilizadas ? a fim de cumprir os critérios de aceitação mais restritivos do mercado têxtil ? foi de 50%. / Abstract : The Advanced Oxidation Processes (AOPs) have emerged as an alternative technology to the treatment of many environmental matrices, among them, the textile wastewaters. This work concerns the application of photochemical oxidation (UVC/H2O2) in the treatment of three real textile wastewaters (ART-A, ART-B, and ART-C), which were previously biologically treated. A kinetic study was performed aiming to determine the optimum operating conditions such as, the dosage of hydrogen peroxide (0 - 100 mM), solution pH (3.0, 5.0, 9.0 and natural wastewater pH: 8.1 (ART-A), 7.7 (ART-B), and 8.3 (ART-C)), and solution temperature (15, 23, 35, and 50 °C). The photolysis of hydrogen peroxide under UVC radiation showed to be an efficient decolourization technology. UVC/H2O2 reaction applied to the ART-A and ART-B resulted in a color reduction of 81% and 68% (Pt-Co method), 83% and 72% (DFZ436nm), 88% and 76% (DFZ525nm) and 86% and 69% (DFZ620nm) using 25 mM H2O2 and 8.3 and 5.5 kJUVC L-1 at 180 min and 120 min of reaction, respectively. The textile wastewater - C (ART-C) presented the parameters for decolourization, such as, less time/energy for decolourization, exit temperature of the biological reactor favorable to the decolourization, and pH of the wastewater itself as the best result for a decolourization. Finally, for the purpose of reuse in textile processing, UVC/H2O2 reaction applied to the ART-C resulted in a color reduction of 92% (Pt-Co method), 94% (DFZ436nm), 96% (DFZ525nm) and 94% (DFZ620nm) using 25 mM H2O2 and 4.1 kJUVC L-1 at 90 min of reaction. The biodegradability of the textile wastewaters was evaluated using the Zahn-Wellens test, and it was observed a significant increase in the percentage of biodegradable carbon along the photo-treatment (62% for TWA and 45% for TWB). ART-C was used in the dyeing of the cotton substrate, and was performed in order to evaluate the reuse capacity of photochemical textile wastewaters treated in textile processing. The maximum percentage of textile waste water treated by photochemical oxidation which can be reused with the purpose of the acceptance criteria and restrictive of the textile market - was 50%.
|
279 |
Influência do meio suporte e da presença de vegetação no desempenho de filtros biológicos percoladores / Influence of the filter media and the presence of vegetation at the performance of biological trickling filtersMartins, Vinícius Ferreira 15 February 2016 (has links)
Submitted by Marco Antônio de Ramos Chagas (mchagas@ufv.br) on 2017-05-18T13:02:30Z
No. of bitstreams: 1
texto completo.pdf: 1075107 bytes, checksum: 115269fdc25234332c893ca4b1000bcc (MD5) / Made available in DSpace on 2017-05-18T13:02:30Z (GMT). No. of bitstreams: 1
texto completo.pdf: 1075107 bytes, checksum: 115269fdc25234332c893ca4b1000bcc (MD5)
Previous issue date: 2016-02-15 / Conselho Nacional de Desenvolvimento Científico e Tecnológico / A situação precária do esgotamento sanitário no Brasil, juntamente com a demanda por sistemas de tratamento de esgoto que contemplem menores custos de implantação, operação e manutenção, faz da tecnologia da biomassa aderida, mais especificamente os filtros biológicos percoladores (FBPs) uma alternativa para o tratamento de esgotos sanitários no país. Visando ampliar os aspectos funcionais do sistema FBP, o presente estudo objetivou avaliar o desempenho de filtros biológicos percoladores com a inserção do capim-vetiver (Chrysopogon zizanioides) nos meios suporte brita e argila expandida, consistindo em uma nova abordagem para o tratamento de esgotos. Para isso, o experimento contou com quatro FBPs com diferentes configurações: FBP AV (argila expandida como substrato, cultivada com vetiver); FBP A (argila expandida como substrato, sem o cultivo de vetiver); FBP BV (brita no1 como substrato, cultivado com vetiver); e FBP B (brita no1 como substrato, sem o cultivo de vetiver). Como resultados as concentrações efluentes de DBO bruta foram de 142, 119, 104 e 120 mg L -1 para FBP AV , FBP A , FBP BV e FBP B , respectivamente, e comparando as concentrações notou-se diferença significativa para FBP A e FBP B provendo os melhores resultados para a DBO bruta. Para fósforo as médias efluentes foram de 6,63, 6,57, 6,42 e 5,61 mg L -1 para FBP AV , FBP A , FBP BV e FBP B , respectivamente e o meio suporte brita (FBP BV e FBP B ) diferiu significativamente da argila (FBP A e FBP AV ), na qual a brita proveu melhor resultado para a remoção de fósforo devido a sua capacidade de retenção e que a vegetação não contribuiu significativamente para a remoção desse parâmetro. As concentrações de nitrogênio total Kjeldahl (NTK) para efluente foram de 39,5, 43,1, 42,1 e 37,7 mg L -1 , nitrogênio amoniacal total (NAT) de 31, 37,9, 37,7 e 31,9 mg L -1 e nitrato de 0,352, 0,027, 0,057 e 0,104 mg L -1 correspondente aos filtros FBP AV , FBP A , FBP BV e FBP B . Analisando a série nitrogenada percebe-se uma tendência do filtro com o meio suporte brita (FBP B ) de se ser mais eficiente em remover as formas mais particuladas de nitrogênio (NTK) e o FBP AV (associação argila/vetiver) ser mais expressivo para as formas dissolvidas (NAT e nitrato). De maneira geral o meio suporte argila expandida e a inserção do capim-vetiver mostraram-se como boas alternativas para o tratamento de esgotos sanitários no FBP. / The precarious sewage management in Brazil together with the demand for low- cost and low-maintenance systems makes the attached biomass technology - specifically the trickling filters (TF) - an alternative for treatment of sewage in developing countries. Aiming to expand the functional aspects of the TF system, this study intended to evaluate the performance of TFs with grown vetiver grass (Chrysopogon zizanioides) in gravel and expanded clay substrates, consisting of a new approach for sewage treatment. Thus, the experiment had four TFs with different configurations: FBP AV (expanded clay media grown with vetiver); FBP A (expanded clay media without vegetation); FBP BV (gravel # 1 media grown with vetiver); and FBP B (gravel # 1 media without vegetation). The effluent concentrations of unfiltered BOD were 142, 119, 104 and 120 mg L -1 for FBP AV , FBP A , FBP BV and FBP B respectively and comparing the concentrations was noticed a statistical difference for FBP A and FBP B providing better results for unfiltered BOD. To phosphorus, the effluent means were 6.63, 6.57, 6.42 and 5.61 mg L -1 for FBP AV , FBP A , FBP BV and FBP B respectively and the gravel media (FBPB V and FBP B ) differed statistically from the expanded clay (FBP A and FBP AV ), where the gravel media provided better results for phosphorus removal due to its retention capacity and the vegetation do not contributed to this removal. The TKN effluent means were 39.5, 43.1, 42.1 and 37.7 mg L -1 , TAN were 31, 37.9, 37.7 and 31.9 mg L -1 and for nitrate 0.352, 0.027, 0.057 and 0.104 mg L -1 corresponding to FBP AV , FBP A , FBP BV and FBP B filters. Analyzing nitrogen series was noticed that gravel media (FBP B ) is more efficient in removing more particulate forms of nitrogen (TKN) and FBP AV (association clay / vetiver) is more expressive for more dissolved forms (TAN and nitrate). In general, booth the expanded clay media and the cultivation of grass vetiver seemed to be a good alternative for the treatment of wastewater in TFs.
|
280 |
Desempenho de estações de tratamento de águas cinzas e negras para residências rurais, envolvendo filtros orgânicos e reatores solares / Performance overview of grey and black water treatment plants for rural residences, involving organic filters and solar reactorsRocha, André Luiz Marques 04 February 2013 (has links)
Submitted by Reginaldo Soares de Freitas (reginaldo.freitas@ufv.br) on 2017-05-31T12:27:30Z
No. of bitstreams: 1
texto completo.pdf: 2353197 bytes, checksum: c7857ff947a3da3dfb17abdaa73dd50c (MD5) / Made available in DSpace on 2017-05-31T12:27:30Z (GMT). No. of bitstreams: 1
texto completo.pdf: 2353197 bytes, checksum: c7857ff947a3da3dfb17abdaa73dd50c (MD5)
Previous issue date: 2013-02-04 / Conselho Nacional de Desenvolvimento Científico e Tecnológico / A água de reuso é uma opção promissora do ponto de vista ambiental, já que contribui para diminuição da captação e consequentemente redução nas vazões de lançamento de efluentes. O lançamento de águas cinzas e águas negras sem tratamento no ambiente deprecia a qualidade de vida das populações em função do surgimento de várias doenças. O presente trabalho objetivou monitorar e avaliar a eficiência de uma estação de tratamento de águas cinzas (ETAC) e de uma estação de tratamento de águas negras (ETAN), visando o reaproveitamento não-potável das águas cinzas e das águas negras em comunidades rurais de baixa renda. A ETAC foi montada na comunidade rural Macena, no município de Viçosa-MG. Tal sistema era constituído de biofiltro, reatores solares e sumidouro, o qual foi monitorado no período de 23 de julho de 2009 a 01 de outubro de 2009. As análises físico-químicas e microbiológicas dos efluentes foram realizadas em distintos pontos do sistema para avaliação do desempenho. A ETAC foi montada no Delineamento Inteiramente Casualizado com três tratamentos (pontos de amostragem) e cinco repetições no tempo. De acordo com os resultados obtidos durante a avaliação da estação de tratamento de águas cinzas (ETAC), conclui-se que a (ETAC) proporcionou eficiências médias de remoções de 28%, 56%, 71,3%, 76,5%, 52,5%, 71%, 61%, 4,6% e 87% nas concentrações de Condutividade Elétrica (CE), Turbidez (TB), Demanda Química de Oxigênio (DQO), Demanda Bioquímica de Oxigênio (DBO), Sólidos Totais (ST), Sólidos Suspensos Totais (SST), Fósforo Total (P total ), Nitrogênio Total (N total ) e Óleos e Graxas (OG), respectivamente. Com relação às características microbiológicas, a ETAC obteve uma eficiência de remoção média de E. coli de 3 unidades logarítmicas. A ETAN foi montada na comunidade rural de Água Limpa do município de Cajuri-MG. Tal sistema foi constituído de caixa de gordura, tanque séptico, biofiltro, reatores solares e sumidouro, o qual foi monitorado no período de 7 de maio de 2009 a 25 de junho de 2009. As análises físico-químicas e microbiológicas dos efluentes foram realizadas em distintos pontos do sistema para avaliação do desempenho. O experimento para tratamento de águas negras foi montado no Delineamento Inteiramente Casualizado com quatro tratamentos (pontos de amostragem) e seis repetições no tempo. De acordo com os resultados obtidos durante a avaliação da estação de tratamento de águas negras (ETAN), conclui-se que a (ETAN) proporcionou eficiências médias de remoções de 46%, 88%, 78,2%, 85,8%, 61,5%, 91%, 75%, 14,4% e 67,8% nas concentrações de Condutividade Elétrica (CE), Turbidez (TB), Demanda Química de Oxigênio (DQO), Demanda Bioquímica de Oxigênio (DBO), Sólidos Totais (ST), Sólidos Suspensos Totais (SST), Fósforo Total (P total ), Nitrogênio Total (N total ) e Óleos e Graxas (OG), respectivamente. Com relação às características microbiológicas, a ETAN proporcionou uma eficiência de remoção média de E. coli de 2 unidades logarítmicas. / The water reuse is a promising alternative for the viewpoint of the environment, contributing to reduced absorption and reduces the flow of effluent discharge. The release of greywater and untreated sewage depreciates environmental quality of life of populations due to the onset of various diseases. This study aimed to monitor and evaluate the capacity of a treatment plant for greywater and a treatment of sewage, for non-potable reuse of greywater and blackwater in communities low-income rural. The treatment plant grey water was set up in the rural community Macena in Viçosa-MG. This system consists of biofilters, solar reactors and sinkhole, which was controlled in the period from July 23, 2009 to October 1, 2009. The physico-chemical and microbiological characteristics of the effluents were realized in different parts of the performance evaluation system. The treatment plant greywater was mounted in a completely randomized design with three treatments (sampling points) and five replications in time. According to the results obtained during the evaluation of the water treatment station ash, it is concluded that this treatment stationgave mean elimination efficiency of 28%, 56%, 71.3%, 76.5 %, 52.5%, 71%, 61%, 4.6% and 87% concentrations of electrical conductivity, turbidity, chemical oxygen demand, biochemical oxygen demand, total solids, total suspended solids, total phosphorus, total oil and grease, nitrogen, respectively. Regarding the microbiological characteristics, the treatment plant greywater obtained an average efficiency of removal of E. coli three logarithmic units.The station blackwater treatment was mounted in the rural community of Água Limpa, in Cajuri-MG.This system consisted of the grease trap, septic tank, biological filter, solar reactors and the sinkhole, which is monitored in the period from May 7, 2009 to June 25, 2009. The physico-chemical and microbiological characteristics of the effluents were carried out in different parts of the performance evaluation system. Experience in wastewater treatment was mounted in a completely randomized design with four treatments (sampling points) and six replications in time. According to the results obtained during the evaluation of treatment plant sludge, is follows that a gave mean elimination efficiency of 46%, 88%, 78.2%, 85.8%, 61.5%, 91%, 75%, 14.4% and 67.8% to levels of electrical conductivity, turbidity, chemical oxygen demand, biochemical oxygen demand, total solids, total suspended solids, total phosphorus, nitrogen total, oil and grease, respectively. Regarding the microbiological characteristics, the station blackwater treatment obtained an average efficiency of removal of E. coli two logarithmic units.
|
Page generated in 0.0569 seconds