• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 62
  • 4
  • 4
  • Tagged with
  • 72
  • 72
  • 37
  • 35
  • 23
  • 21
  • 20
  • 19
  • 18
  • 17
  • 17
  • 17
  • 17
  • 13
  • 13
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
71

Efeito do protocolo de ativação da polimerização e envelhecimento acelerado em algumas propriedades de cimentos resinosos / Effects of polymerization activation protocol and accelerated aging in some resin cements properties

Thiago Amadei Pegoraro 26 February 2010 (has links)
Este estudo teve como objetivo avaliar os efeitos de variações no protocolo de ativação e envelhecimento acelerado em algumas propriedades de cimentos resinosos de polimerização dual. Adicionalmente, investigaram-se os efeitos da variação da temperatura ambiente e envelhecimento acelerado no tempo de trabalho e tempo de presa dos cimentos quando ativados exclusivamente pela reação química. As propriedades avaliadas foram o grau de conversão, determinado por espectrometria no infravermelho com transformada de Fourier (FTIR-ATR), microdureza Knoop, expressa em KHN, e resistência mecânica à tração expressa em MPa. Os tempos de trabalho e tempos de presa foram determinados por um reômetro oscilatório com controle de temperatura da plataforma de teste estabelecida em 24oC ou 37oC. O envelhecimento acelerado foi determinado pela armazenagem dos cimentos, em suas embalagens originais, e após os testes iniciais, em estufa a 37oC por 12 semanas.A variável de modo de ativação foi determinada em 3 níveis. Os cimentos foram manipulados de acordo com as instruções dos fabricantes e ativados por luz imediatamente (controle), ativados por luz após 10 minutos de reação química no escuro (Exp 1) ou mantidos no escuro por 15 minutos, permitindo a reação química, mas sem fotoativação (Exp 2). Os cimentos tiveram suas propriedades avaliadas em função desses diferentes modos de ativação, antes e após o envelhecimento acelerado. Cimento exclusivamente ativado pela reação química foi empregado como controle quando necessário. Os diversos resultados podem ser resumidos em alguns aspectos de interesse. O tempo de trabalho e o tempo de presa de todos cimentos foram afetados significantemente pela temperatura e envelhecimento (p<0.05). O aumento da temperatura acelerou os tempos de trabalho e presa. Os efeitos do envelhecimento foram materiaisdependentes. Alguns materiais apresentaram redução, enquanto outros apresentaram aumento dos tempos de trabalho e presa, independentemente da variação da temperatura. O modo de ativação e envelhecimento afetaram significantemente as propriedades dos cimentos (p<0.05). Em geral, o grau de conversão aumentou com o tempo após a fotoativação. O retardo da fotoativação por 10 minutos causou alterações no grau de conversão, independentemente do envelhecimento, e para alguns produtos somente. O envelhecimento afetou a cinética da reação química de polimerização dos cimentos. Alguns materiais não apresentaram suficiente reação química após o envelhecimento. As propriedades variaram amplamente de acordo com o modo de ativação e produto. O envelhecimento foi a variável que causou alterações mais significantes e com grande implicação na utilização clínica dos produtos. Alguns materiais se tornaram impróprios para uso após o envelhecimento acelerado. / The study aimed to evaluate the effects of curing protocol and accelerated aging on some properties of dual-cure resin cements. Additionally, the effects of different ambient temperature and aging on the working and setting times were investigated when cements were self-cured only. Properties evaluated were degree of conversion as determined by FTIR-ATR spectroscopy, Knoop microhadness as expressed by KHN, and tensile strength as expressed in MPa. Working time and setting time were determined by an oscilating rheometer with controlled temperature stage at either 24oC or 37oC. Accelerated aging was performed by storing the original product kits in an oven at 37oC for 12 weeks after initial testing had been executed. Different curing protocols were established in 3 levels. Cements were manipulated according to the manufacturers instructions and light-activated immediately (control), light-activated after 10 minutes delay of self-curing in the dark (Exp 1), or simply allowed to self-cure for 15 minutes in the dark (Exp 2). Properties were evaluated according to the different curing protocol and both before and after aging. Exclusively self-curing cement was used as control product when appropriate. The results can be summarized in some aspects of interest. The working time and setting time of all products were significantly affected by temperature and aging (p<0.05). Increased temperature resulted in shorter working time and setting time. The effects of aging were material dependent. Some products presented reduced working and setting times, while others behave otherwise, regardless of the temperature. Curing mode and aging significantly affected the properties of the cements (p<0.05). In general, the degree of conversion increased with time after light-activation. The curing delay for 10 minutes caused alterations in the degree of conversion, regardless of aging, for some products, but not all. Aging affected the curing kinectics and general properties of all cements. Some materials did not present sufficient cure after aging. Properties varied widely according to curing protocol and product. Aging was the variable that most affected the products and the most relevant regarding the clinical use of the materials. Some products were deemed improper for clinical use after accelerated aging.
72

Uso de materiais diretos e indiretos para amplas restaurações: implicações clínicas e laboratoriais / Use of direct and indirect materials for extensive restorations: clinical and laboratory implications

Skupien, Jovito Adiel 14 March 2014 (has links)
Made available in DSpace on 2014-08-20T14:30:19Z (GMT). No. of bitstreams: 1 Tese_Jovito_Adiel_Skupien.pdf: 8297294 bytes, checksum: 72ce694b2bb9e499cf0353c4c4b8df4e (MD5) Previous issue date: 2014-03-14 / Glass fiber posts and composite resins are widely used materials in restorative dentistry. The various forms of presentation and technical approach, as well as different handling prior to their use, can result in diverse outcomes, which can determine the success or failure of the restorative procedure. Thus, the aim of this study was to evaluate the performance of glass fiber posts and composite resins in front of several factors related to it uses in dentistry. For this, the study was divided into three parts: An in vitro study, an in vivo study and a systematic review. The in vitro study aimed to evaluate the effect of cementation delay of indirect composite resin restorations in previously hybridized dentin. Three strategies of cementation were tested through different protocols. Beam-shaped specimens from tooth/restoration were obtained and submitted to microtensile testing to evaluate the bond strength and types of failures, where the results were analyzed by ANOVA and Tukey s post hoc tests and linear regression. Regular cement and adhesive threestep etch-and-rinse adhesive system showed the highest values of bond strength, followed by the same cement and two-step etch-and-rinse adhesive system and the lowest values for self-adhesive cement groups. Linear regression showed an improvement in the bond strength values when three-step adhesive system was used, however, all groups had adequate values of bond strength, even in unfavorable situations. The randomized clinical trial evaluated the longevity of metal-ceramic crown and composite resin restorations performed in endodontically treated teeth that received a glass fiber post. Fifty-six severely damaged teeth but with at least one entire wall were randomly allocated into two groups according to the type of restoration. The longevity was assessed through Kaplan-meier and clinical evaluation by descriptive analysis. The recall rate was 100%, fifty-six teeth were re-evaluated with no absolute failure. However, eight composite resin restorations had failed (all reparable). A significant difference between type of restoration was found. Indirect restorations provided higher acceptable clinical performance after two-year of followup, although composite failures were liable to repair. The systematic review compared factorts that can influence retention of glass fiber posts to intraradicular based on in vitro studies which compared the bond strength of resin cements. Searches were carried out in Pubmed and Scopus database up to December 2013. Thirty-four studies were included in the review and several variables were extracted. The presence of endodontic treatment significantly decrease the bond strength, meanwhile other variables can influence according to the type of resin cement. Thus, factors as type of cement application and pretreatment of post can influence glass fiber post retention, however, self-adhesive resin cements are less sensitive to luting procedures / Pinos de fibra de vidro e resinas compostas são materiais amplamente utilizados em odontologia restauradora. As diferentes formas de apresentação e técnicas de emprego, bem como diferentes manobras prévias às suas utilizações podem implicar em desfechos clínicos mais ou menos favoráveis, que podem determinar o sucesso ou falha de um procedimento restaurador. Assim, o objetivo deste estudo foi avaliar o desempenho de pinos de fibra de vidro e resinas compostas frente a diversos fatores relacionados ao seu uso em odontologia. Para isso, o estudo foi dividido em três partes: estudo in vitro, estudo in vivo e revisão sistemática. O estudo in vitro objetivou avaliar o efeito do retardamento da cimentação de restaurações indiretas de resinas compostas em dentina previamente hibridizada. Três estratégias de cimentação foram testadas com diferentes protocolos. Palitos do conjunto dente/restauração foram obtidos e submetidos ao teste de microtração para avaliação da resistência de união e padrão de fratura, onde os valores foram analisados através de ANOVA e teste post hoc Tukey (!=0,05) e regressão linear. Cimento convencional e sistema adesivo de 3 passos apresentaram os maiores valores de resistência de união, seguidos do mesmo cimento e sistema de 2 passos, sendo os menores valores para o grupo do cimento auto-adesivo. A regressão linear demonstrou uma melhora significativa nos valores de resistência quando o sistema de 3 passos foi utilizado, entretanto, todos os grupos tiveram resultados adequados, mesmo em condições desfavoráveis. O ensaio controlado randomizado avaliou a longevidade de restaurações metalo-cerâmicas e de resinas compostas confeccionadas em dentes tratados endodonticamente que receberam um pino de fibra de vidro. Cinqüenta e seis dentes com a coroa danificada, porém, com uma face intacta, foram alocados em dois grupos aleatoriamente, de acordo com o tipo de restauração. A longevidade das restaurações foi avaliadas através de Kaplan- Meier e critérios clínicos foram analisados de forma descritiva. Com uma taxa de rechamada de 100%, 56 dentes foram reavaliados e nenhum foi perdido. Porém, 8 restaurações de resina composta falharam e sofreram reparos. Houve uma diferença significativa para o tipo de restauração em relação ao sucesso. Assim, restaurações indiretas apresentaram uma melhor performance clínica após 2 anos de acompanhamento, embora as falhas apresentadas no grupo que recebeu resinas diretas tenham sido reparáveis. A revisão sistemática comparou fatores que podem influenciar na retenção de pinos de fibra de vidro em dentina intra-radicular baseado em estudos in vitro que compararam a resistência de união de cimentos resinosos. Após uma busca realizada nos bancos de dados Pubmed e Scopus até dezembro de 2013, trinta e quatro estudos foram incluídos na revisão e diferentes variáveis foram extraídas. A presença de tratamento endodôntico diminuiu significativamente a resistência de união, enquanto que demais variáveis variam sua influência de acordo com o tipo de cimento resinoso. Assim, fatores como método de aplicação do cimento e pré-tratamento do pino podem influenciar a retenção de pinos de fibra de vidro, porém, cimentos auto-adesivos são menos sensíveis à técnica de cimentação

Page generated in 0.3729 seconds