421 |
Investigations in the correlation between hardness and flexural strength of composite resin restorative materials /Roeske, Svenja. January 1900 (has links)
Diss. med. dent. Zürich. / Literaturverz.
|
422 |
Contribuação dos estudos sobre alterações dimensionais, de resistência à tracção e de resistência ao dobramento, em corpos de prova de gesso, conseqüente à sua fratura, seguida de colagem Continuation of the studies about dimensional changes, traction and flexural strength in samples of gypsum, in consequence of their fractures, followed by sticking /Springmann, Werner. January 1975 (has links)
Thesis--Universidade federal de Santa Catarina, 1975.
|
423 |
Avaliação in vitro da biocompatibilidade de resinas acrílicas para base de próteses e materiais reembasadores resilientesChaves, Carolina de Andrade Lima [UNESP] 24 July 2013 (has links) (PDF)
Made available in DSpace on 2014-08-13T14:50:34Z (GMT). No. of bitstreams: 0
Previous issue date: 2013-07-24Bitstream added on 2014-08-13T18:01:13Z : No. of bitstreams: 1
000734605.pdf: 2209864 bytes, checksum: acb17f8f0ad0805c7336b7a12bf4ea7d (MD5) / O objetivo deste estudo foi avaliar a citotoxicidade de 3 resinas acrílicas (RA) para bases de prótese sendo duas polimerizadas por energia de microondas (Vipi Wave-VW e Nature Cryl-NC) e uma fotoativada (Eclipse-E); e a biocompatibilidade de materiais reembasadores resilientes (MRR), sendo 2 à base de silicone (Ufi Gel P e Sofreliner S), 2 à base de resina acrílica (Durabase Soft e Trusoft) e 2 condicionadores de tecidos (Softone e Coe Comfort) por meio de análises do metabolismo celular, da morfologia celular, do padrão de morte celular, da proliferação celular e da expressão do fator de crescimento TGFß 1, da integrina α5ß1 e de citocinas. A análise das RA foi realizada com células L929; para os MRR, as análises foram realizadas utilizando-se células L929, e/ou HaCaT e/ou RAW 264,7. Os resultados obtidos foram submetidos à análise estatística, realizada ao nível de significância de 5%. Todos os materiais quando testados com eluatos não apresentaram efeitos citotóxicos, e quando testados em contato direto (MTT e azul de alamar) alteraram significativamente a viabilidade celular, tendo sido os menores valores observados para o material NC quando comparado ao E. Para os materiais reembasadores o T, S e C. Maior taxa de necrose e apoptose foram observadas para os eluatos de todos os materiais quando avaliados no período de 24 horas; além disso, foi demonstrado que os materiais avaliados podem desencadear a expressão do TGFß 1, da integrina α5ß1 e de proteínas inflamatórias (fator de necrose tumoral - TNF-α, da citocina IL-1ß e de 5 quimiocinas: CCL2, CCL3, CCL5, CXCL2 e CXCL4). Sendo assim, de acordo com as limitações do presente estudo, pode-se concluir que a resina Nature Cryl resultou em menor viabilidade celular que a resina Eclipse e que os materiais Ufi Gel P e Sofreliner S apresentaram, em geral, melhor bicompatibilidade dentre os materiais reembasadores resilientes avaliados. / The aim of this study was to evaluate the cytotoxicity of 3 denture base acrylic resins with different polymerization methods (Eclipse, Vipi Wave and Nature Cryl) and the biocompatibility of soft lining materials, 2 silicone-based (Ufi Gel P and Sofreliner S), 2 acrylic-based (Durabase Soft and Trusoft) and 2 tissue conditioners (Softone and Coe Comfort), by analysing cell metabolism, cell morphology, pattern of cell death, cell proliferation and expression of growth factor TGFß 1, integrin α5ß1 and cytokines. For the acrylic resins, analyses were made with L929 cells, while for the resilient lining materials, analyzes were performed using L929, and/or HaCaT and/or RAW 264.7 cells. Results were statistically analyzed, at a significance level of 5%. The 24 and 48-h eluates from all materials were not cytotoxic to the cells. For the direct contact tests (MTT and Alamar Blue), a significant effect on cell viability was found, with the lowest values observed for materials NC when compared with E and between the reliners Trusoft, Softone and Coe Comfort. For all materials, increased rate of necrosis and apoptosis were observed for the 24 hs eluates. It was also demonstrated that all materials tested can trigger the expression of TGFß 1, α5ß1 integrin and inflammatory proteins (tumor necrosis factor -TNF-α, cytokine IL-1ß and 5 chemokines- CCL2, CCL3, CCL5, CXCL2 and CXCL4). Thus, within the limitations of this study, it can be concluded that the denture base acrylic resin Nature Cryl resulted in lower cell viability compared to the Eclipse resin and that the materials Ufi Gel P and Sofreliner S showed better biocompatibility among the soft liner materials evaluated.
|
424 |
Avaliação da influência do método de polimerização e da espessura da base de próteses totais na porosidade da resina acrílicaPero, Ana Carolina [UNESP] [UNESP] 17 February 2005 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:55Z (GMT). No. of bitstreams: 0
Previous issue date: 2005-02-17Bitstream added on 2014-06-13T20:58:46Z : No. of bitstreams: 1
pero_ac_me_arafo.pdf: 475502 bytes, checksum: 7962f5d801f2cc928c6960616073f175 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / O objetivo do presente trabalho foi avaliar a porosidade em bases de resina acrílica de prótese total maxilar, processadas em diferentes ciclos de polimerização e confeccionadas em três espessuras (2,0, 3,5 e 5,0 mm). Cinco grupos foram estabelecidos, de acordo com os ciclos de polimerização: A) Onda-Cryl, ciclo curto em microondas; B) Onda-Cryl, ciclo longo em microondas; C) Onda-Cryl, ciclo do fabricante; T) Clássico, banho de água; Q) Jet, ciclo em câmara de pressão. Após o seu processamento, as bases de resina acrílica foram pesadas em ar e em água e a porcentagem de porosidade foi relacionada com a absorção de água no interior desse material. Os dados de % de porosidade foram submetidos ao teste de Kruskal-Wallis para a comparação entre os grupos (a= 5%). Dentro das limitações do presente estudo, concluiu-se que os ciclos de polimerização e a espessura do espécime de resina acrílica têm influência na porosidade, já que diferenças estatisticamente significantes foram encontradas entre os ciclos e espessuras avaliados. Não houve diferença de porosidade entre as bases de resina polimerizadas no ciclo T para qualquer uma das espessuras. / The aim of this study was to evaluate the porosity on (acrylic resin) maxilar complete denture bases, processed through diferent polimerization cycles, procedure done in three different kinds of thickness (2,0, 3,5 e 5,0 mm). Five groups were proposed, according to the polimerization cycles: A) Onda-Cryl, short microwave cycle; B) Onda-Cryl, long microwave cycle; C) Onda-Cryl, manufacturing microwave cycle; T) Clássico, water bath; Q) Jet, press chamber cycle. After the process, the denture bases were weighted in air and in water, and the percent of porosity was related to the water absorption within this material. The porosityþs % data were submitted to the Kruskal-Wallis test to promote the comparison among the groups. In despite of the present paperþs limitations, we have concluded that the polimerization cycles and the specimenþs thickness of acrylic resin really influence the porosity. This result was reached because statistically significant differences were found in the cycles and thickness evaluated. It has been not observed porosity differences in the polimerized resin bases in T cycle in relation to any thickness.
|
425 |
Efeito de diferentes tratamentos térmicos sobre o conteúdo de monômero residual de resinas acrílicas para reembasamentoUrban, Vanessa Migliorini [UNESP] 27 February 2003 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:56Z (GMT). No. of bitstreams: 0
Previous issue date: 2003-02-27Bitstream added on 2014-06-13T19:16:53Z : No. of bitstreams: 1
urban_vm_me_arafo.pdf: 1219036 bytes, checksum: 4e3be4eb79ce75a36f6d11fd248eff4f (MD5) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / O objetivo deste estudo foi estabelecer, inicialmente, um método analítico em CLAE, para comparar o conteúdo de monômero residual de uma resina autopolimerizável para reembasamento imediato (Duraliner II - D) e uma resina termopolimerizável utilizada na confecção de bases de próteses (Lucitone 550 - L). Além disso, foi avaliado o efeito de dois tratamentos térmicos sobre esse conteúdo. Os monômeros utilizados como padrões foram o MMA (resina L) e o BMA (resina D). As condições cromatográficas para a análise foram: coluna ODS (15,0 x 0,46 cm), com 5 mm de tamanho de partícular e 100 Å de tamanho de poro, fase móvel ACN : H2O (55%: 45%) + 0,01% TEA, fluxo 0,8 mL/min, l 230 nm, volume de injeção 100 mL. As resinas foram proporcionadas e polimerizadas de acordo com as instruções dos fabricantes. Os corpos-de-prova (n = 18) dos dois materiais foram divididos em 3 grupos, com 6 corpos-de-prova cada. O grupo I (GI) não foi submetido a nenhum tratamento (controle). Para o grupo II (GII), os corpos-de-prova foram irradiados com microondas, a 550 W por 3 min para o material L e a 650 W por 4 min para o material D. Para o grupo III (GIII), os corpos-de-prova dos materiais L e D foram submetidos ao tratamento térmico por imersão em água a 55oC por 60 min e 10 min, respectivamente. Cada corpo-de-prova foi, então, fragmentado e submetido ao procedimento de extração em MeOH por 2 horas. Os valores de conteúdo de monômero residual foram transformados em porcentagem e analisados pelo teste de Kruskall-Wallis, ao nível de confiança de 99%. Em todos os grupos avaliados, o material D apresentou valores médios de monômero residual (GI - 0,87%; GII - 0,71%; GIII - 0,52%) significativamente maiores (p<0,01) que o material L (GI - 0,09%; GII - 0,06%; GIII - 0,05%). De acordo com a metodologia utilizada neste estudo, foram obtidas as seguintes conclusões: 1) O método... / The aim of this study was to firstly establish an analytical method, which was the most satisfactory with reference to optimization of chromatographic conditions for HPLC. The method was then used to compare the residual monomer content in one hard chair-side reline resin (Duraliner II - D) and one heat-polymerized denture base resin (Lucitone 550 - L). Also, it was investigated the effect of two after polymerization heat-treatments on this residual monomer content. The HPLC operating conditions established were column ODS (15.0 x 0.46 cm), with 5 mm particles, mobile phase - 55% ACN : 45% deionized distilled water, flow injection rate - 0.8 mL/min., wave length detection - UV 230 nm, amount of sample solution injection 100 mL. Calibration curves were produced using standard solutions containing known amounts of each monomer evaluated (MMA - L; BMA - D) in mobile phase. The materials (D and L) were mixed and polymerized according to the manufacturer's instructions. Specimens (n = 18) of both materials were then divided into three groups, of six specimens each. Group I specimens were left untreated (GI - control). Specimens of group II (GII) were given heat treatment by microwave irradiation with 550 W for 3 min for material L and 650 W for 4 min for material D. For group III (GIII), L and D specimens were submitted to a heat-treatment by immersion in water at 55oC for 60 min and 10 min, respectively. Each specimen were cut into small pieces and subjected to an extraction procedure in methanol for 2 hours. The residual monomer content was then expressed as a percentage of residual monomer in the specimen. The percentage residual monomer data were analyzed by non-parametric Kruskall-Wallis test, at 99% level of confidence. In all groups evaluated, material D showed significantly higher (p<0.01) residual monomer mean values (GI - 0.87%; GII - 0.71%; ...(Complete abstract, click electronic access below)
|
426 |
Efeito da complementação térmica de polimerização sobre a resistência flexural e dureza de resinas acrílicas para reembasamentoSeó, Rosangela Seiko [UNESP] 25 February 2003 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:56Z (GMT). No. of bitstreams: 0
Previous issue date: 2003-02-25Bitstream added on 2014-06-13T19:58:18Z : No. of bitstreams: 1
seo_rs_me_arafo.pdf: 703350 bytes, checksum: 5c30291cb31b160b0c3ae925308ad49c (MD5) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / O procedimento de reembasamento da prótese é normalmente utilizado para restabelecer a adaptação entre a prótese e o tecido bucal. As resinas autopolimerizáveis são um dos materiais indicados para o reembasamento. No entanto, tem sido demonstrado que, após a polimerização das resinas autopolimerizáveis, nem todo o monômero é convertido em polímero e esse monômero residual pode afetar as propriedades mecânicas desses materiais. Estudos têm sugerido que o conteúdo de monômero residual pode ser reduzido pela irradiação em microondas ou tratamento em banho de água. Esse estudo avaliou o efeito dos tratamentos térmicos sobre a resistência à flexão e dureza Vickers de quatro resinas autopolimerizáveis para reembasamento (Duraliner II - D, Kooliner-K, Tokuso Rebase Fast - TR e Ufi Gel Hard - UGH) e uma resina termopolimerizável (Lucitone 550 - L). Para cada material, trinta corpos-de-prova foram confeccionados e igualmente divididos em três grupos. No grupo controle, os corpos-de-prova foram submetidos ao teste de resistência à flexão imediatamente após sua polimerização. Previamente ao teste, os grupos 2 e 3 foram submetidos ao tratamentos complementares em banho de água e irradiação por microondas, respectivamente. Os corpos-de-prova do material para base de prótese foram armazenados em água por 48 horas a 37o l 1oC previamente ao teste. As medidas de força foram realizadas em máquina de ensaio universal MTS 810 com uma velocidade de 5 mm/min, utilizando o teste em três pontos a uma distância de 50 mm entre os apoios. Em seguida, um dos fragmentos do corpo-de-prova foi submetido ao teste de dureza Vickers. Os valores de dureza foram determinados utilizando-se uma carga de 25 gf (resinas K, TR, L e UGH) e 10 gf para a resina D, após 30 segundos de contato. Doze mensurações de dureza foram realizadas em cada corpo-de-prova e... / To maintain the prosthesis-tissue relationship, denture base reline procedure is commonly required. Autopolymerizing resins are one of the materials indicated for relining. It has been shown that, after polymerization, not all the monomer is converted to polymer in autopolymerizing resins and this residual monomer could detrimentally affect the mechanical properties of the materials. It has been suggested that the residual monomer could be decreased by microwave irradiation or water bath heat-treatments. This study investigated the effect of heat treatments on the flexural strength and Vickers hardness of four autopolymerizing reline resins (Duraliner II - D, Kooliner-K, Tokuso Rebase Fast-TR and Ufi Gel Hard-UGH) and one heat-polymerized resin (Lucitone 550-L). For each material, 30 specimens were made and equally divided into three groups. In control group, the specimens were submitted to the flexural strength test immediately after polymerization. Before testing, groups 2 and 3 were submitted to water bath and microwave post-cure treatments, respectively. The denture base material specimens were stored in water for 48 h at 37o l 1oC before they were bend-tested. Force measurements were made with a testing machine MTS 810 at a crosshead speed of 5 mm/min using a three-point bending fixture with a span of 50 mm. Thereafter, one fragment of specimen was submitted to Vickers microhardness test. The values were determined by using a 25 gf load (resins K, TR, UGH and L) and 10 gf for resin D, after 30 s contact. Twelve hardness measurements were taken on each specimen and the average was then calculated. Kruskal-Wallis non-parametric test was used for determination of statistical significance (p<0.01). The results demonstrated that: compared to the control groups, the flexural strength of TR and...(Complete abstract, click electronic access below)
|
427 |
Influência da interposição de diferentes cerâmicas no grau de conversão de agentes cimentantes resinososMarinho, Márcio Leandro Von Dreifus [UNESP] 01 March 2010 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:57Z (GMT). No. of bitstreams: 0
Previous issue date: 2010-03-01Bitstream added on 2014-06-13T20:58:50Z : No. of bitstreams: 1
marinho_mld_me_araca.pdf: 375522 bytes, checksum: 570c0f27d21f52f32fceab1b3e2a8557 (MD5) / 3M ESPE / O objetivo deste estudo foi avaliar o grau de conversão de agentes cimentantes resinosos polimerizados sob diferentes espessuras de cerâmica feldspática e diferentes sistemas cerâmicos de mesma espessura. No primeiro estudo, oitenta amostras dos cimentos resinosos RelyX ARC (3M Espe) e RelyX Veneer (3M Espe) foram confeccionadas sob discos de cerâmica convencional Starlight (DeguDent) com espessuras de 0,5mm, 1,2mm, 1,8mm e 2,4mm. No segundo estudo, oitenta amostras dos cimentos resinosos RelyX ARC (3M Espe) e Maxcem Elite (Kerr) foram confeccionadas sob discos de diferentes sistemas cerâmicos: Starlight (DeguDent), Empress (Ivoclair Vivadent), E-max (Ivoclair Vivadent), In Ceram Alumina (Vita) e In Ceram Zircônia (Vita) com espessuras de 2,0mm. A leitura do grau de conversão dos cimentos resinosos foi realizada 10 minutos, 1 hora e 24 horas após a fotoativação dos cimentos, em espectrofotômetro FTIR Nexus 670 (Nicolet). Os resultados do primeiro estudo mostraram que o cimento resinoso dual RelyX ARC apresentou maior grau de conversão que o cimento fotoativado RelyX Veneer em todas as espessuras de cerâmica, inclusive sem interposição (p<0.0001). Os valores de grau de conversão obtidos após 1 hora e 24 horas não diferiram estatisticamente entre si (p=0.7433), mas foram superiores aos analisados após 10 minutos (p<0.0001). Para o cimento fotoativado, houve aumento gradativo no grau de conversão de 10 minutos até 24 horas (p<0.0001). No segundo estudo, os maiores valores de grau de conversão foram obtidos para as amostras polimerizadas sob as cerâmicas reforçadas por leucita e dissilicato de lítio, sem diferença estatisticamente significante entre si (p=0.1181), enquanto os menores valores do grau de conversão obtidos foram das amostras polimerizadas sob cerâmicas reforçadas por alumina e zircônia, sem diferença entre si (p=0.2374). Com base nos resultados destes... / The aim of this study was to evaluate the degree of conversion of resin cements polymerized under different thicknesses of feldspatic ceramic and different ceramic systems with the same thickness. In the first study, eighty samples of RelyX ARC (3M Espe) and RelyX Veneer (3M Espe) were polymerized under conventional ceramic discs (Starlight, DeguDent) with thickness of 0.5 mm 1.2 mm, 1.8 mm and 2.4 mm. In the second study, eighty samples of RelyX ARC (3M Espe) and Maxcem Elite (Kerr) resin cements were polymerized over ceramics systems: Starlight (DeguDent), Empress (Ivoclar Vivadent), E-max (Ivoclar Vivadent), In Ceram Alumina (Vita) and In Ceram Zircon (Vita) with 2.0 mm of thickness. The degree of conversion of the resin cements was calculated 10 minutes, 1 hour and 24 hours after the curing of cements using a Nexus 670 FTIR spectrophotometer (Nicolet). The RelyX ARC showed higher values of degree of conversion than RelyX Veneer considering all the ceramics thickness in the first study. The measurements obtained after 1 hour and 24 hours did not differ significantly (p=0.7433), but were higher than those analyzed after 10 minutes (p<0.0001). Comparing the ceramic systems in the second study, the highest degree of conversion were obtained for samples polymerized under Empress and e.max ceramics, without statistically difference between them (p= 0.1181) and the lower values of conversion were obtained for the samples polymerized under In Ceram Alumina and In Ceram Zircon ceramics (p= 0.2374). Based on the results of these studies, we can conclude that the thickness of feldspatic porcelain as well as the ceramic system itself could influence the degree of conversion of light- and dual-cured resin cements. All the resin cements showed an increase on the degree of conversion after 24 hours, which could create an especial guideline for the clinical procedures using resin cements
|
428 |
Análise da estabilidade de cor de botões de íris artificiais obtidos por diferentes técnicas e após o envelhecimento aceleradoBannwart, Lisiane Cristina [UNESP] 23 April 2012 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:57Z (GMT). No. of bitstreams: 0
Previous issue date: 2012-04-23Bitstream added on 2014-06-13T20:18:38Z : No. of bitstreams: 1
000737733.pdf: 1813264 bytes, checksum: 5276c6bddbc491cf01ada48860d5d3d6 (MD5) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / As próteses oculares são responsáveis pela recuperação da estética e auto-estima do usuário. As técnicas existentes para a confecção da prótese ocular devem resultar em íris artificiais perfeitamente estéticas com conseqüente dissimulação do defeito facial. Dessa forma, este estudo tem como propósito verificar a alteração de cor do botão de íris artificial entre diferentes técnicas após a polimerização e o envelhecimento acelerado. Foram confeccionadas 60 amostras simulando próteses oculares distribuídas em grupos (n=10) de acordo com a técnica utilizada, sendo: PE: técnica convencional sem verniz, PEV: técnica convencional com verniz, CA: técnica com calota pré-fabricada sem verniz, CAV: técnica com calota pré-fabricada com verniz, PI: técnica da pintura invertida sem verniz, PIV: técnica da pintura invertida com verniz. A leitura de cor foi realizada por meio de um espectrofotômetro de reflexão ultravioleta visível utilizando o sistema CIE L*a*b*, antes e após polimerização, e após 252, 504 e 1008 de envelhecimento acelerado. Os dados obtidos foram submetidos à análise de variância (ANOVA), e teste de Tukey (p<0,05). O teste de cor mostrou que após polimerização e envelhecimento acelerado todas as amostras apresentaram alteração significativa da cor, porém, as amostras com verniz protetor de tinta tiveram menor alteração em todos os períodos analisados. / Ocular prostheses are responsible not only for the recovery of aesthetic but also for the self-esteem of the anophthalmic patient. The techniques used to fabricate ocular prosthesis should result in artificial iris with adequate aesthetic and natural appearance. When such characteristics are not achieved, the fabrication of new prosthesis is indicated even in the presence of good fit of the old prosthesis. Additionally, the color instability of iris is the most relevant factor that affects the longevity of ocular prosthesis, and is related to the polymerization process of the acrylic resin and its clinical use over time. Therefore, the present study investigated the color alteration of artificial iris buttons obtained by different techniques after polymerization and accelerated aging. A total of 60 samples simulating an ocular prosthesis were fabricated and divided into groups (n=10) according to the technique used: PE – conventional technique without varnish; PEV - conventional technique with varnish; CA - Prefabricated cap technique without varnish; CAV - Prefabricated cap technique with varnished; PI - Reverse painting technique without varnish; PIV - Reverse painting technique with varnish. Color measurements were performed by using a visible ultraviolet reflection spectrophotometer with the CIE L*a*b* system, before and after polymerization, and after 252, 504 and 1008 hours of accelerated aging. Data were submitted to analysis of variance (ANOVA) and Tukey test (p<.05). After polymerization and accelerated aging periods all samples exhibited statistically color alteration; however, the varnished samples had lower color change for all periods.
|
429 |
Influência da adição de nanopartículas na estabilidade de cor, microdureza e resistência à flexão de resina específica para confecção de próteses ocularesAndreotti, Agda Marobo [UNESP] 31 January 2014 (has links) (PDF)
Made available in DSpace on 2015-03-03T11:52:46Z (GMT). No. of bitstreams: 0
Previous issue date: 2014-01-31Bitstream added on 2015-03-03T12:07:03Z : No. of bitstreams: 1
000795011.pdf: 3623811 bytes, checksum: d8263b2bba7ed088e7be14e351d1311c (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / Uma alternativa segura para reabilitar pacientes com anoftalmia é a utilização de próteses oculares. O conhecimento das propriedades físicas e mecânicas da resina acrílica utilizada na confecção destas próteses é de suma importância. Nanopartículas vêm sendo adicionadas à cadeia polimérica das resinas com o objetivo de melhorar essas propriedades. Assim, o propósito desse estudo foi avaliar a influência da adição de nanopartículas na estabilidade de cor, microdureza e resistência à flexão da resina acrílica N1 específica para confecção da esclera artificial. Para isso, foram confeccionadas 300 amostras. As nanopartículas utilizadas foram Óxido de Zinco (ZnO), Dióxido de Titânio (TiO2) e Sulfato de Bário (BaSO4), nas concentrações de 1, 2 e 2,5%. As amostras foram distribuídas em 10 grupos (n=30) de acordo com o tipo e concentração de nanopartícula associada à resina acrílica N1: controle - sem nanopartícula (C), óxido de zinco 1% (ZnO 1%), óxido de zinco 2% (ZnO 2%), óxido de zinco 2,5% (ZnO 2,5%), dióxido de titânio 1% (TiO2 1%), dióxido de titânio 2% (TiO2 2%), dióxido de titânio 2,5% (TiO2 2,5%), sulfato de bário 1% (BaSO4 1%), sulfato de bário 2% (BaSO4 2%), sulfato de bário 2,5% (BaSO4 2,5%). Os ensaios de leitura de cor, microdureza e resistência à flexão foram realizados antes e após 1008 horas de envelhecimento acelerado. Os dados obtidos foram submetidos à análise estatística, utilizando-se os testes de nested ANOVA e teste de Tukey. Os resultados demonstraram que, comparando-se as diferentes nanopartículas, os grupos com TiO2 apresentaram melhor estabilidade de cor, para todas as concentrações. Em relação ao teste de microdureza, com exceção dos grupos C e com adição de óxido zinco, os valores de microdureza aumentaram após envelhecimento, sendo que, nas concentrações de 1 e 2%, os grupos com... / A safe, aesthetic and satisfactory alternative to rehab patients with anofthalmia is the use of ocular prosthesis. It is very important to know about the physical and mechanical properties of the acrylic resin used on this prosthesis production. Nanoparticles have been added to the acrylic resins polymeric chain in order to improve these properties. So, this study aims to assess the influence of nanoparticles addition on the color stability, microhardness, and flexural resistance of artificial sclera N1 acrylic resin. To this purpose, 300 samples were made. The nanoparticles used were Zinc Oxide (ZnO), Titanium Dioxide (TiO2) and Barium Sulfate (BaSO4), at the concentrations of 1, 2 and 2%. Samples were divided into 10 groups (n=30), according to the nanoparticle and concentration associated with the resin: control – without nanoparticle (C); zinc oxide 1% (ZnO 1%) ; zinc oxide 2% (ZnO 2%); zinc oxide 2,5% (ZnO 2,5%); titanium dioxide 1% (TiO2 1%); titanium dioxide 2% (TiO2 2%); titanium dioxide 2,5% (TiO2 2,5%); barium sulfate 1% (BaSO4 1%), barium sulfate 2% (BaSO4 2%); barium sulfate 2,5% (BaSO4 2,5%). The color stability, microhardness and flexural resistance tests were performed before and after 1008 hours of accelerated aging. Data were subjected to statistical analysis using nested ANOVA and Tukey test. The results showed that, comparing the different nanoparticles, the groups with TiO2 showed better color stability at all concentrations. Microhardness values increased after artificial aging, except for groups C and ZnO and groups with TiO2 at 1 and 2% showed the highest statistically significant values compared with the other nanoparticles. Regarding flexural strength, at initial period, there was statistically significant difference between control group and the other groups. By comparing the periods, the C group... / FAPESP: 12/02907-0
|
430 |
Avaliacao da resistencia a tracao de um sistema adesivo self - etching em dentina irradiada com ER: YAG laserMELLO, ANDREA M.D. de 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:44:45Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T13:58:01Z (GMT). No. of bitstreams: 1
06998.pdf: 4836505 bytes, checksum: 8807c39ebe15873ea228aaf490e0ed91 (MD5) / Dissertacao (Mestrado Profissionalizante em Lasers em Odontologia) / IPEN/D-MPLO / Intituto de Pesquisas Energeticas e Nucleares, IPEN/CNEN-SP; Faculdade de Odontologia, Universidade de Sao Paulo
|
Page generated in 0.2841 seconds