11

Projeto em tempo discreto de controladores ressonantes aplicados a fontes ininterruptas de energia

Keiel, Guilherme January 2017 (has links)
Este trabalho apresenta um estudo da discretização de controladores ressonantes aplicados a fontes ininterruptas de energia (UPSs, do termo em inglês, Uninterruptible Power Suppllies). Primeiramente, diferentes métodos de discretização serão considerados na obtenção de um modelo em tempo discreto da UPS. Além disso, estes métodos serão comparados do ponto de vista frequencial para a definição da formulação do controlador ressonante a ser utilizado. Então, uma metodologia de projeto robusto do controlador ressonante em tempo discreto é proposta a partir de uma representação em espaço de estados do sistema em malha fechada e os parâmetros do controlador são obtidos através da solução de um problema de otimização convexa sujeito a restrições na forma de Desigualdades Matriciais Lineares (do inglês, Linear Matrix Inequalities - LMIs). A estratégia proposta foi validada por meio de resultados de simulação e experimentais obtidos com um inversor comercial de 3,5 kVA considerando os critérios estabelecidos na norma IEC 62040-3. Nestas condições, demonstrara-se um desempenho melhor do que os obtidos com a discretização do controlador projetado em tempo contínuo, sobretudo quando consideradas frequências de amostragem menores. / This work presents a study about discrete-time resonant controllers applied to uninterruptible power supplies (UPSs). First, different discretization methods are considered to obtain an equivalent UPS discrete-time model. Moreover, these methods are compared in the frequency domain in order to define the resonant controller structure to be employed. Then, a robust design methodology to the discrete-time resonant controller is proposed using a state-space representation of the closed-loop system and the controller parameters are obtained by solving a convex optimization problem subject to constraints in the form of Linear Matrix Inequalities (LMIs). The proposed strategy was validated by means of simulation and experimental results obtained with a 3.5 kVA commercial inverter taking into account the IEC 62040-3 norm requirements. In this conditions, a better performance was achieved than those obtained through discretization of a continuous-time controller, especially when considering smaller sampling frequencies.
12

Projeto em tempo discreto de controladores ressonantes aplicados a fontes ininterruptas de energia

Keiel, Guilherme January 2017 (has links)
Este trabalho apresenta um estudo da discretização de controladores ressonantes aplicados a fontes ininterruptas de energia (UPSs, do termo em inglês, Uninterruptible Power Suppllies). Primeiramente, diferentes métodos de discretização serão considerados na obtenção de um modelo em tempo discreto da UPS. Além disso, estes métodos serão comparados do ponto de vista frequencial para a definição da formulação do controlador ressonante a ser utilizado. Então, uma metodologia de projeto robusto do controlador ressonante em tempo discreto é proposta a partir de uma representação em espaço de estados do sistema em malha fechada e os parâmetros do controlador são obtidos através da solução de um problema de otimização convexa sujeito a restrições na forma de Desigualdades Matriciais Lineares (do inglês, Linear Matrix Inequalities - LMIs). A estratégia proposta foi validada por meio de resultados de simulação e experimentais obtidos com um inversor comercial de 3,5 kVA considerando os critérios estabelecidos na norma IEC 62040-3. Nestas condições, demonstrara-se um desempenho melhor do que os obtidos com a discretização do controlador projetado em tempo contínuo, sobretudo quando consideradas frequências de amostragem menores. / This work presents a study about discrete-time resonant controllers applied to uninterruptible power supplies (UPSs). First, different discretization methods are considered to obtain an equivalent UPS discrete-time model. Moreover, these methods are compared in the frequency domain in order to define the resonant controller structure to be employed. Then, a robust design methodology to the discrete-time resonant controller is proposed using a state-space representation of the closed-loop system and the controller parameters are obtained by solving a convex optimization problem subject to constraints in the form of Linear Matrix Inequalities (LMIs). The proposed strategy was validated by means of simulation and experimental results obtained with a 3.5 kVA commercial inverter taking into account the IEC 62040-3 norm requirements. In this conditions, a better performance was achieved than those obtained through discretization of a continuous-time controller, especially when considering smaller sampling frequencies.
13

Projeto de controladores para o seguimento de referências periódicas em sistemas com atuadores saturantes

Flores, Jeferson Vieira January 2012 (has links)
Este trabalho aborda o problema de seguimento e rejeição de sinais periódicos em sistemas lineares sujeitos a saturação nos atuadores. Para garantir o seguimento/rejeição, dois controladores baseados no princípio do modelo interno são considerados: o primeiro baseia-se no modelo interno em sua formulação clássica, isto é, um controlador dinâmico contendo um número finito de modos (marginalmente) instáveis da referência/perturbação é introduzido na malha de controle, em uma abordagem chamada de controladores ressonantes; a segunda abordagem considera o controlador repetitivo, onde um elemento de atraso é inserido namalha de controle emumlaço de realimentação positiva, fazendo o papel do modelo interno de ordem infinita. Nos dois casos, o objetivo principal é a obtenção de condições na forma de inequações matriciais lineares (do inglês, Linear Matrix Inequalities - LMIs) para a síntese simultânea de uma realimentação de estados estabilizante e do ganho do laço estático de anti-windup. Partindo do pressuposto que as referências e perturbações pertencem a um certo conjunto admissível, estes ganhos garantem que as trajetórias do sistema em malha fechada inciadas em um certo conjunto elipsoidal convergem para outro conjunto elipsoidal invariante contido na região de operação linear do sistema. Nesta região, a presença do modelo interno na malha de controle garante o seguimento e a rejeição dos sinais de interesse. Nas duas abordagens são propostos problemas de otimização visando a maximização do conjunto invariante de estados admissíveis e/ou a maximização do conjunto de referências/perturbações admissíveis. Extensões da metodologia para sistemas de tempo discreto também são apresentadas. / This work addresses the tracking/rejection problem of periodic signals for linear systems subject to control saturation. To ensure the tracking/rejection, two internal model based controllers are considered: the first one considers the internal model in a classical framework, i.e. a dynamic controller containing a finite number of (marginally) unstable modes of the reference/disturbance signal is introduced in the control loop. In this work, this approach is called resonant controller. The second approach considers the repetitive controller, where a delay element is introduced in the control loop in a positive feedback loop, playing the role of an infinite order internal model. In both cases, the main objective is to obtain conditions in the form of LMIs to simultaneously compute a stabilizing state feedback gain and an anti-windup gain. Assuming that the references and disturbances signals belong to a certain admissible set, these gains guarantee that the trajectories of the closed-loop system starting in a certain ellipsoidal set contract to another invariant ellipsoidal set inside the linearity region of the closed-loop system. In this region the presence of the internal model ensures tracking/rejection of the considered periodic signals. In both frameworks, optimization problems aiming at the maximization of the invariant set of admissible states and/or the maximization of the set of admissible references/disturbances are proposed. Extensions of the proposed framework to discrete-time systems are also presented.
14

Projeto de controladores para o seguimento de referências periódicas em sistemas com atuadores saturantes

Flores, Jeferson Vieira January 2012 (has links)
Este trabalho aborda o problema de seguimento e rejeição de sinais periódicos em sistemas lineares sujeitos a saturação nos atuadores. Para garantir o seguimento/rejeição, dois controladores baseados no princípio do modelo interno são considerados: o primeiro baseia-se no modelo interno em sua formulação clássica, isto é, um controlador dinâmico contendo um número finito de modos (marginalmente) instáveis da referência/perturbação é introduzido na malha de controle, em uma abordagem chamada de controladores ressonantes; a segunda abordagem considera o controlador repetitivo, onde um elemento de atraso é inserido namalha de controle emumlaço de realimentação positiva, fazendo o papel do modelo interno de ordem infinita. Nos dois casos, o objetivo principal é a obtenção de condições na forma de inequações matriciais lineares (do inglês, Linear Matrix Inequalities - LMIs) para a síntese simultânea de uma realimentação de estados estabilizante e do ganho do laço estático de anti-windup. Partindo do pressuposto que as referências e perturbações pertencem a um certo conjunto admissível, estes ganhos garantem que as trajetórias do sistema em malha fechada inciadas em um certo conjunto elipsoidal convergem para outro conjunto elipsoidal invariante contido na região de operação linear do sistema. Nesta região, a presença do modelo interno na malha de controle garante o seguimento e a rejeição dos sinais de interesse. Nas duas abordagens são propostos problemas de otimização visando a maximização do conjunto invariante de estados admissíveis e/ou a maximização do conjunto de referências/perturbações admissíveis. Extensões da metodologia para sistemas de tempo discreto também são apresentadas. / This work addresses the tracking/rejection problem of periodic signals for linear systems subject to control saturation. To ensure the tracking/rejection, two internal model based controllers are considered: the first one considers the internal model in a classical framework, i.e. a dynamic controller containing a finite number of (marginally) unstable modes of the reference/disturbance signal is introduced in the control loop. In this work, this approach is called resonant controller. The second approach considers the repetitive controller, where a delay element is introduced in the control loop in a positive feedback loop, playing the role of an infinite order internal model. In both cases, the main objective is to obtain conditions in the form of LMIs to simultaneously compute a stabilizing state feedback gain and an anti-windup gain. Assuming that the references and disturbances signals belong to a certain admissible set, these gains guarantee that the trajectories of the closed-loop system starting in a certain ellipsoidal set contract to another invariant ellipsoidal set inside the linearity region of the closed-loop system. In this region the presence of the internal model ensures tracking/rejection of the considered periodic signals. In both frameworks, optimization problems aiming at the maximization of the invariant set of admissible states and/or the maximization of the set of admissible references/disturbances are proposed. Extensions of the proposed framework to discrete-time systems are also presented.
15

CONTROLE DE CORRENTE APLICADO EM INVERSOR MONOFÁSICO DE TENSÃO / CURRENT CONTROL APPLIED IN SINGLE-PHASE VOLTAGE INVERTERS

Lima, Marcel Soares 20 February 2015 (has links)
Made available in DSpace on 2016-08-17T14:52:39Z (GMT). No. of bitstreams: 1 DISSERTACAO_MARCEL SOARES LIMA.pdf: 17818100 bytes, checksum: 95b36384b873fd5da81040a537b53ec1 (MD5) Previous issue date: 2015-02-20 / With advancement of power electronics and the wide range of applications involving single-phase inverter voltage, current controllers has gained great prominence, because they control the flow of energy supplied to the grid or to a load and compensate some quality energy problems. For this, various techniques for controlling power has been studied in order to meet the robustness characteristics, accuracy and speed of response. In addition, another important characteristic, which has been adopted for accurately determining the choice of the current driver is the possibility of eliminating disturbances in specific frequency, such as those caused by harmonicas of the fundamental signal. This paper presents the study, analysis and resonant controller design. Since this controller is equivalent to adding two PI controllers synchronously, a positive sequence and negative sequence other, implemented in the stationary frame of reference, we will investigate the possible resonance structures of controlling synchronous equivalent to PI controllers, and vector classic and the advantages and disadvantages of each. The analyses of resonant controllers are held in the continuous domain and then the drivers are implemented in discrete domain, taking into account the computational delay. It is also performed the analysis and design of strategies for controlling resonant with and without a delay compensator. Finally, experimental tests will be performed to confirm the analyzes in this paper. / Com o avanço da eletrônica de potência e a vasta gama de aplicações que envolvem os inversores monofásicos de tensão, os controladores de corrente têm ganhado grande destaque, pois controlam o fluxo de energia fornecida à rede elétrica ou a uma carga e compensam alguns problemas de qualidade de energia. Para isso, diversas técnicas de controladores de corrente têm sido estudadas com o intuito de atender as características de robustez, precisão e rapidez na resposta. Além disso, outra característica importante, e que tem sido rigorosamente adotada para determinar a escolha dos controladores de corrente, é a possibilidade de eliminar distúrbios em frequências específicas, como por exemplo, aqueles causados por harmônicas do sinal fundamental. Esta dissertação apresenta o estudo, análise e projeto do controlador ressonante. Uma vez que este controlador é equivalente à adição de dois controladores PI síncronos, um de sequência positiva e outro de sequência negativa, implementados no referencial estacionário, serão investigados as possíveis estruturas dos controladores ressonantes equivalentes aos controladores PI síncronos, clássico e vetorial, bem como as vantagens e desvantagens de cada um. As análises dos controladores ressonantes são realizadas no dominio contínuo e, posteriormente, os controladores são implementados no dominio discreto, levando em consideração o atraso computacional. Também é realizada a análise e projeto das estratégias de controladores ressonantes com e sem um compensador de atraso. Por fim, serão realizados ensaios experimentais para confirmar as análises realizadas no decorrer deste trabalho.
16

Operation of Three Phase Four Wire Grid Connected VSI Under Non-Ideal Conditions

Ghoshal, Anirban January 2013 (has links) (PDF)
The necessity to incorporate renewable energy systems into existing electric power grid and need of efficient utilization of electrical energy are growing every day. A shunt connected Voltage Source Inverter(VSI) capable of bidirectional power flow and fast control has become one of the building block to address such requirements. However with growing number of grid connected VSI, new requirements related to harmonic injection, higher overall efficiency and better performances during short term grid disturbances have emerged as challenges. For this purpose a grid connected three phase four wire VSI with LCL filter can be considered as a general module to study different control approaches and system behavior under ideal and non-ideal grid conditions. This work focuses on achieving enhanced performance by analyzing effect of non-ideal conditions on system level and relating it to individual control blocks. In this work a phase locked loop structure has been proposed which is capable of extracting positive sequence fundamental phase information under non-ideal grid conditions. It can also be used in a single phase system without any structural modification. The current control for the three phase four wire VSI system has been implemented using Proportional Resonant (PR) controller in a per phase basis in stationary reference frame. A simplified controller design procedure based on asymptotic representation of the system transfer function is proposed. Using this method expressions for controller gains can be derived. A common mode model of the inverter system has been derived for low frequencies. Using this model a controller is designed to mitigate DC bus imbalance caused by sensor and ADC channel offsets. A multi-rate approach for digital implementation of PR controller with low resource consumption, that is suitable for an FPGA like digital controller ,is proposed. This multi-rate method can maintain resonance frequency accuracy even at low sampling frequency and can easily be frequency adaptive. Anti-wind up methods for PI controller have been studied to find suitable anti-wind up methods for PR controller. The tracking anti-wind up method is shown to be suitable for use with a PR controller. The effectiveness of this method under sudden disconnection and reconnection of VSI from grid is experimentally verified. A resonant integrator based second order filter is shown to be useful for active damping of LCL filter resonance with a wide range of grid inductance variation. The proposed method utilizes the LCL filter capacitor voltage to estimate resonance frequency current. Suitability of fundamental current PR controller for active damping alone, and with the proposed method show the superiority of the proposed method especially for low switching frequencies. Design oriented analysis of the above topics are included in the thesis. The theoretical understandings developed have been verified through experiments in the laboratory and can be readily implemented in industrial power electronic systems.
17

Modes d'Alimentation et de Commande des lampes sodium haute pression en vue d’éviter les résonances acoustiques / Supply and control methods for acoustic resonances avoidance in high intensity discharge lamp

Chhun, Labo 07 May 2010 (has links)
Grâce au développement de la technologie des semi-conducteurs, les ballasts électroniques fonctionnant en haute fréquence offrent des avantages considérables par rapport aux ballasts électromagnétiques conventionnels. Il en résulte une augmentation de la durée de vie de la lampe, une diminution du volume et du poids du système et surtout un meilleur contrôle de son fonctionnement afin de réduire notamment la consommation électrique. Parmi des lampes à décharge, la lampe sodium haute pression a une excellente efficacité lumineuse et une longue durée de vie. Pourtant, quand la lampe fonctionne en haut fréquence, des perturbations de type « résonance acoustique (RA) » peuvent entraîner l’instabilité de la décharge, son extinction ou pire, la destruction de la lampe. Cette thèse, intitulée « Modes d’Alimentation et de Commande des lampes sodium haute pression en vue d’éviter les résonances acoustiques », traite de plusieurs problèmes. Les caractéristiques de la décharge haute pression, le phénomène de RA, ses conditions d’excitation (notamment au travers d’un phénomène d’hystérésis original) et la variation des paramètres électriques due à la présence de résonances acoustiques dans la lampe, ont été étudiés. Les résultats sont issus de travaux de simulation et expérimentaux menés au sein du laboratoire LAPLACE. Grâce à ces acquis fondamentaux, plusieurs nouvelles méthodes d’alimentation par l’injection de signaux à fréquences proches ont été proposées dans nos travaux. Il s’agit d’éviter la résonance acoustique dans la lampe alimentée par un ballast de structure très réduite par rapport aux solutions classiques. Cette méthode est basée sur le choix judicieux des signaux injectés dans la lampe et leur répartition, (alimentation par deux, trois ou cinq signaux, répartition symétrique, asymétrique totale ou partielle). Le résultat est un meilleur étalement du spectre et donc une réduction de puissances harmoniques sélectionnées permettant de s’adapter, à terme aux conditions d’excitation des RA, mais aussi les limitations de ces méthodes compte tenu du facteur crête. Enfin, différents types de commande en boucle fermée sont proposés, ils permettent d’assurer la stabilité de la décharge et le contrôle des puissances imposées dans la lampe. Les études théoriques, en simulation et expérimentales qui ont été conduites nous ont permis d’aboutir à des résultats concluants. / For high pressure sodium (HPS) lamps, the progress of semi-conductor technology has provided considerable advantages in the design of high frequency operated electronic ballasts, compared to conventional electromagnetic ballasts. The advantages deal with lamp lifetime improvement, ballast volume and mass reduction, and particularly with a better control of lamp operation for optimized power consumption. Among discharge lamps, high pressure sodium (HPS) lamp has excellent efficacy and long lifetime. However, when it is operated at high frequency, discharge perturbation namely “acoustic resonances (AR)” can provoke some lamp arc instabilities, extinction or, even worst, lamp destruction. The present thesis, entitled “Supply and control methods for acoustic resonances avoidance in high intensity discharge lamps” deals with several matters.  High intensity discharge (HID) characteristics, AR phenomenon, its excitation conditions (including the original features of AR hysteresis) and lamp electrical parameters variation due to AR presence, will be studied. The obtained results were provided by simulations and experimentations carried out in LAPLACE laboratory. Thanks to the acquired results of previous studies, several novel lamp supply strategies via adjacent frequency signals injection were proposed. The main concepts here consist in the avoidance of AR presented in a lamp supplied by designed electronic ballast with reduced structure, compared to classical solutions. Otherwise, the presented methods are based on pertinent choices of injected signals applied to the lamp and their frequency distributions (two, three or five signals and symmetric, partial asymmetric or total asymmetric signals). The studies actually showed better spreading of signal spectrum and power harmonic amplitudes reduction adapted to AR excitation conditions, while taking into account crest factor limitation. Finally, different control laws (PI, Hysteresis, Self-oscillation, Resonant controllers) were also proposed in order to guarantee lamp discharge stabilization and power controls. The theoretical and experimental studies including simulations were conducted to reach concluding results of our works.
18

Otimização meta heurística e controle baseado no modelo interno aplicados em sistemas de geração fotovoltaica conectados à rede elétrica monofásica

Chaves, Eric Nery 18 November 2016 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Este trabalho apresenta o estudo, desenvolvimento e aplicação de novas técnicas de controle aos sistemas de geração de energia fotovoltaica, conectados à rede elétrica monofásica, visando a melhoria da eficiência destes sistemas em relação aos métodos de controle tipicamente utilizados. O trabalho é dividido em duas partes principais, as quais estão relacionadas ao rastreamento do ponto de máxima potência (Maximum Power Point Tracking – MPPT) e, depois, ao controlador interno dos conversores boost-quadrático – lado dos painéis fotovoltaicos – assim como aos controladores do inversor de tensão, no lado da rede elétrica monofásica. A primeira parte do trabalho consiste no desenvolvimento de um algoritmo de meta heurística para o MPPT, o qual é baseado no método do recozimento simulado (Simulated Annealing - SA) e tem como objetivo a determinação do ponto de máximo global, buscando soluções fora de uma vizinhança próxima, de modo a evitar o atracamento em máximos locais da curva de potência de saída do arranjo de painéis fotovoltaicos, melhorando, assim, o aproveitamento da energia em situações de sombreamento parcial. A segunda parte do trabalho apresenta o projeto de controladores baseados no modelo interno (Internal Model Control – IMC) com 1 grau de liberdade (1 Degree of Freedom – 1 DOF) aplicados, primeiramente, ao conversor CC-CC Boost Quadrático, utilizado para o MPPT, e, posteriormente, a um inversor de tensão com filtro LCL, conectado à rede elétrica monofásica, operando no modo de injeção de corrente. É apresentada a modelagem matemática de ambos os conversores e analisada a compensação da realimentação interna ao sistema do inversor de tensão, correspondente ao desacoplamento da tensão da rede, através da estratégia de alimentação à frente (Feedforward). Visando-se uma base de comparação, para a análise de desempenho do conversor IMC – 1DOF, também é aplicado ao sistema de injeção de corrente, o controlador Proporcional-Ressonante (P+Res). São apresentados resultados de simulação computacional e experimentais de ambos os 8 controladores, os quais permitem verificar o desempenho do sistema em situação de rede fraca e carga local não-linear. / This paper presents the study, development and application of new control techniques for photovoltaic power generation systems, connected to single-phase power grid in order to improve the efficiency of these systems in relation to control methods typically used. The work is divided into two main parts, which are related to tracking the maximum power point (Maximum Power Point Tracking - MPPT) and then the internal controller of boost quadratic converters - side of the photovoltaic panels - as well as the controllers the voltage inverter, the side of the single-phase mains. The first part of the work is the development of a heuristic goal algorithm for MPPT, which is based on the method of simulated annealing (Simulated Annealing - SA) and aims at determining the overall maximum point, seeking out solutions in a close vicinity, so as to prevent the docking local maxima in the curve of power output of the photovoltaic array, thereby improving the utilization of energy in partial shading situations. The second part presents the design of controllers based on internal model (Internal Model Control - IMC) with 1 degree of freedom (1 Degree of Freedom - 1 DOF) applied, first, the DC-DC Boost Quadratic converter, used for MPPT, and thereafter, a voltage inverter with LCL filter connected to the single phase power supply operating in current injection mode. A mathematical modeling of both converters and analyzed the compensation of internal feedback to the voltage inverter system corresponding to the disconnection of the mains voltage through the power strategy a head (feedforward). A basis of comparison for the performance analysis of IMC-1DOF converter is aiming at, is also applied to the current injection system, Proportional-Resonant Controller (P + Res). They are presented computer simulation and experimental results of both controllers, which allow you to check the system performance in low and non-linear local load network situation. / Tese (Doutorado)
19

Controladores baseados no princípio do modelo interno com ação Anti-Windup / Controllers basead on internal model principle with anti-windup

Soares, Claudio Eduardo 28 April 2011 (has links)
Made available in DSpace on 2016-12-12T17:38:37Z (GMT). No. of bitstreams: 1 CLAUDIO EDUARDO SOARES.pdf: 20046362 bytes, checksum: 135e6d7d3a6f98bef9152afe645904c4 (MD5) Previous issue date: 2011-04-28 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / The controllers based on the internal model principle have found emphasis on control systems due to its ability to perform robust tracking of signals whose generator models are embedded in their internal structures. Controllers with integral, resonant and repetitive terms are examples of this principle. However, the control systems are subject to physical limitations that restrict their operation under certain conditions. The amplitude saturation of the control action is the most common type of restriction found in real systems. The impacts of the saturation of control action are known as windup and its consequences for systems with integral action have already been exhaustive examined. However, the impacts of saturation of control action are not restricted to this type of controller. Other controllers based on the internal model principle are also affected by the windup phenomenon due to saturation of the action control. The impacts of the windup phenomenon for resonant, multi-resonant and repetitive controllers are investigated in this dissertation and an anti-windup technique is suggested to mitigate the impacts of the control saturation on these controllers. The proposed anti-windup technique is based on the conditional integration technique, originally developed for the controllers with integral action, and it is named conditional update. Simulation results are presented to validate the proposed technique. / Os controladores baseados no princípio do modelo interno têm encontrado destaque no controle de sistemas devido a sua capacidade de realizar o rastreamento robusto dos sinais cujos modelos geradores estejam embutidos nas suas estruturas internas. Os controladores com ação integral, ressonantes e repetitivos são exemplos da aplicação deste princípio. Contudo, os sistemas de controle estão sujeitos a limitações físicas que restringem suas condições de operação. A saturação da amplitude da ação de controle é o tipo de limitação mais comum encontrada nos sistemas reais. Os impactos da saturação da ação de controle são conhecidos como windup e suas consequências para os sistemas com ação integral já foram exaustivamente analisadas. Porém, os impactos da saturação da ação de controle não se restringem a este tipo de controlador. Outros controladores baseados no princípio do modelo interno também são afetados pelo fenômeno windup decorrente da saturação da ação de controle. Os impactos do fenômeno windup sobre os controladores ressonantes, multiressonantes e repetitivos são investigados nesta dissertação e uma técnica anti-windup é sugerida para atenuar os impactos da saturação da ação de controle sobre estes controladores. A técnica anti-windup proposta é baseada na técnica da integração condicional, originalmente desenvolvida para os controladores com ação integral e, por isso, denominada de atualização condicional. Resultados de simulação são apresentados para validação da técnica proposta.
20

Alimentação de cargas hospitalares críticas utilizando conversores estáticos

Oliveira, Yuri Calil Loures de 12 January 2016 (has links)
Submitted by Renata Lopes (renatasil82@gmail.com) on 2016-05-05T18:23:07Z No. of bitstreams: 1 yuricalillouresdeoliveira.pdf: 2613361 bytes, checksum: b14d216c9e91ffe085e35724d58bc704 (MD5) / Approved for entry into archive by Adriana Oliveira (adriana.oliveira@ufjf.edu.br) on 2016-06-07T15:42:11Z (GMT) No. of bitstreams: 1 yuricalillouresdeoliveira.pdf: 2613361 bytes, checksum: b14d216c9e91ffe085e35724d58bc704 (MD5) / Made available in DSpace on 2016-06-07T15:42:11Z (GMT). No. of bitstreams: 1 yuricalillouresdeoliveira.pdf: 2613361 bytes, checksum: b14d216c9e91ffe085e35724d58bc704 (MD5) Previous issue date: 2016-01-12 / CNPq - Conselho Nacional de Desenvolvimento Científico e Tecnológico / Esta dissertação apresenta um estudo de estratégias de alimentação de cargas hospitalares críticas utilizando conversores estáticos de energia. As cargas hospitalares escolhidas foram os equipamentos de raio x, tomografia computadorizada e ressonância magnética, sendo comparadas as seguintes formas de integração à rede: (i) estrutura com um retificador trifásico conectado à rede e três inversores monofásicos conectados às cargas ou (ii) estrutura com três retificadores monofásicos conectados à rede e três inversores monofásicos conectados às cargas. Por questões de patente, houve dificuldade em se encontrar os circuitos de front-end das fontes de alimentação das cargas hospitalares. Logo, as mesmas foram construídas dentro do ambiente de simulação do software PSIM utilizando dados de medição obtidos na literatura. O controle dos retificadores trifásico e monofásico foi realizados utilizando duas malhas de controle em cascata, com a malha interna controlando a corrente consumida da rede e a malha externa regulando a tensão no barramento CC. Para os três inversores monofásicos de saída foram implementados os controles PI RES e PI SRF visando uma comparação quanto ao desempenho. Como forma de validar o modelo matemático do sistema e o algoritmo de controle, foram feitas simulações utilizando o software PSIM. A análise feita comprovou que os resultados de simulação se mostraram coerentes com a modelagem matemática do sistema. / This master thesis presents a study about feeding strategies of critical hospital loads through power static converters. The chosen hospital loads were the x ray equipment, the computed tomography and the magnetic resonance. The following forms of grid integration were compared: (i) structure with a three-phase rectifier connected to the network and three single-phase inverters connected to the loads or (ii) structure with three single-phase rectifiers connected to the network and three single-phase inverters connected to the loads. Due to patent issues, it was difficult to find the front-end circuits for power supplies of hospital loads. Therefore, the loads were implemented in PSIM software environment using measurement data obtained from literature. The control of three-phase and single-phase rectifiers was implemented using two cascaded control loops, with the inner loop controlling the current drawn from the network and the outer loop regulating the DC bus voltage. For the single-phase inverter, PI RES and PI SRF controls were implemented, targeting a comparison in terms of performance. In order to validate the mathematical model of the system and the control algorithm, simulations were performed using the PSIM software. The analysis showed that the simulation results were consistent with the mathematical modeling of the system.