• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 462
  • 14
  • 14
  • 14
  • 11
  • 8
  • 6
  • 6
  • 2
  • 2
  • 2
  • 1
  • Tagged with
  • 469
  • 156
  • 127
  • 78
  • 62
  • 49
  • 46
  • 42
  • 37
  • 33
  • 32
  • 31
  • 30
  • 28
  • 28
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
251

Obtenção de microcápsulas poliméricas contendo um agente formador de filme em seu núcleo para o desenvolvimento de revestimentos autorreparadores. / Development of polymeric microcapsules containing a film-forming agent to design self-healing coatings.

Cotting, Fernando 19 October 2017 (has links)
A aplicação de uma ou mais camadas de tinta sobre as superfícies metálicas é a maneira mais comum e eficaz de proteger os substratos metálicos contra o fenômeno da corrosão. No entanto, os sistemas de pintura podem vir a falhar precocemente por diferentes motivos, causando um ataque corrosivo inesperado no metal a ser protegido. Por esta razão, o processo de repintura em estruturas metálicas é realizado frequentemente para garantir a integridade da estrutura pintada e aumentar sua vida útil. Como o processo de repintura gera impactos econômicos e ambientais, sistemas de pintura capazes de sofrerem uma reparação sem a necessidade de uma intervenção humana, precisam ser desenvolvidos. O encapsulamento de agentes de reparação, com propriedades de formação de filme, em microcápsulas poliméricas é uma excelente alternativa para que os sistemas de pintura se autorreparem, aumentando os intervalos de repintura. Após o processo de encapsulamento, as microcápsulas contendo o agente de reparação são incorporadas na preparação da tinta, para que o sistema de pintura seja aplicado sobre a estrutura metálica. Este tipo de aditivação confere ao revestimento a propriedade de autorreparação, pois quando o sistema de pintura é danificado as microcápsulas são rompidas e liberam o agente de reparação no local danificado, protegendo novamente o substrato metálico. Neste trabalho foi desenvolvido um sistema autorreparador monocomponente, através do microencapsulamento de uma resina a base de éster de epóxi, pelo método de polimerização in-situ. Também foi desenvolvido um sistema autorreparador bicomponente, através do microencapsulamento de uma resina a base de epóxi, pelo método de emulsão e polimerização in-situ de ureia-formaldeído-melamina e do seu endurecedor a base de poliamida, pelo método de extração de solvente em paredes de poliestireno. Foi realizado um planejamento estatístico para estudar a emulsão precursora das microcápsulas de poli(ureia-formaldeído-melamina) contendo o sistema monocomponente, onde foram estudados: o tipo e a velocidade de agitação, a presença de cloreto de sódio na formulação, o uso de uma sonda ultrassônica após a etapa de dispersão, a concentração de tensoativo na formulação e o tensoativo utilizado. Como variáveis de resposta foram determinadas: a estabilidade visual das emulsões e o diâmetro das gotículas formadas. A melhor condição de emulsificação determinada foi utilizada para a obtenção das microcápsulas de poli(ureia-formaldeídomelamina) contendo a resina éster de epóxi e das microcápsulas de poli(ureiaformaldeído-melamina) contento a resina epóxi. Entre as condições de emulsificação estudadas, apenas a condição utilizando o tensoativo goma arábica possibilitou a obtenção das microcápsulas de poli(ureia-formaldeído-melamina) na faixa de diâmetro desejada. O método escolhido para o encapsulamento do endurecedor possibilitou a obtenção de microcápsulas de poliestireno, porém com uma baixa capacidade de armazenamento. A liberação dos agentes de reparação encapsulados foi observada pela microscopia óptica e comprovada pela técnica de espectroscopia na região do infravermelho (FTIR) e pela técnica de espectroscopia Raman. Os aditivos autorreparadores desenvolvidos (mono e bicomponente) foram adicionados separadamente em uma tinta epóxi, nas proporções mássicas em base seca de 10 e 15 %. O sistema de pintura foi aplicado em um esquema de três camadas e o aditivo de autorreparação foi incorporado na primeira e/ou segunda camada aplicada. O sistema de pintura contendo o aditivo autorreparador monocomponente apresentou um aspecto visual melhor do que o sistema de pintura contendo o aditivo autorreparador bicomponente, porém o sistema bicomponente forneceu melhores propriedades de aderência, de impermeabilidade, anticorrosivas e de autorreparação à tinta aditivada. As medidas com as técnicas eletroquímicas de espectroscopia de impedância eletroquímica (EIE) e de varredura com eletrodo vibratório (SVET) comprovaram que os dois aditivos desenvolvidos proporcionaram o efeito autorreparador aos sistemas de pintura aditivados, quando estes foram danificados mecanicamente com uma microbroca ou com um estilete. Ensaios acelerados de corrosão em câmara de névoa salina e ensaios de exposição ao intemperismo natural mostraram que os aditivos desenvolvidos promoveram uma proteção adicional ao aço carbono, quando o sistema de pintura foi danificado mecanicamente. / The application of one or more coating layers on the metallic surfaces is the most common and effective way to protect metallic substrates against corrosion. Nevertheless, the coating layer may fail early for different reasons, leading to an unexpected corrosive attack on the protected metal. For this reason, the coating repair process is performed to ensure the integrity during the service life of the coated metallic structures. Due to the fact that coating repair process generates economic and environmental impacts; there is a great need for the development of systems capable to repair themselves, without human intervention. The encapsulation of repairing agents, with film forming properties, in polymeric microcapsules is an excellent alternative to the coating self-repair, decreasing the coating repair process frequency. After the encapsulation process, the microcapsules containing the repair agent are incorporated into the paint preparation and the coating system could be applied normally to the metallic surface. This kind of additivation confers to the coating the self-healing property, because when the coating system is damaged the microcapsules suffers a rupture and release the repair agent into the damaged site, protecting the metallic substrate from corrosion. In this work, a mono-component self-healing system was developed, through the microencapsulation of an epoxy ester resin, by the in-situ polymerization method. A bi-component self-healing system was also developed, by the microencapsulation of an epoxy resin, through the emulsion and in-situ polymerization method and by the microencapsulation of a polyamide hardener, by the double emulsion and solvent extraction method. A factorial design was developed to study the precursor emulsion of the poly (urea-formaldehyde-melamine) microcapsules containing the monocomponent system, where the studied factors were: the type and speed of the agitation, the presence of sodium chloride in the formulation, the use of an ultrasonic probe after the emulsification, the surfactant type and concentration. The analyzed response variables were: the visual stability of the emulsions and the mean diameter of the formed droplets. The best obtained emulsification conditions were employed to produce the poly(urea-formaldehyde-melamine) microcapsules containing the epoxy ester resin and poly(urea-formaldehyde-melamine) microcapsules containing the epoxy resin. Among the studied emulsification conditions, only using arabic gum surfactant the poly (urea-formaldehyde-melamine) microcapsules were obtained. The selected method for the hardener encapsulation was efficient to obtain polystyrene microcapsules, but with low loading capacity. The release of the encapsulated repair agents was observed by optical microscopy and confirmed by infrared spectroscopy (FTIR) technique and Raman spectroscopy technique. The developed self-healing additives (mono and bicomponent) were added separately in an epoxy commercial coating, using the dry mass ratios 10% and 15 %. The coating system was applied in a three layer coating system and the self-healing additive was incorporated into the first and/or second layer. The coated samples containing the mono-component additive had a better visual appearance than the bi-component additive system; nevertheless the bi-component system provided better adhesion, impermeability, anti-corrosion and self-healing properties to the doped coating. The electrochemical impedance spectroscopy (EIS) and scanning vibrating electrode technique (SVET) measurements proved that the two developed additives provided self-healing properties to the doped coating systems, when they were mechanically damaged with a micro drill or a blade. Accelerated corrosion tests in the salt spray chamber and natural atmospheric corrosion tests showed that the developed additives provided an additional protection to the carbon steel, when the coating system has been mechanically damaged.
252

Reformulação de esmaltes cerâmicos a partir de vidros de CRT / Reformulation of ceramic glazes from recycled CRT glass

Revelo Tobar, Raul Julian 23 September 2014 (has links)
A atual problemática da disposição de resíduos eletroeletrônicos estimula a realização de pesquisas visando o reaproveitamento desse tipo de resíduo na fabricação de novos produtos ou na utilização dos mesmos em processos já existentes. O descarte de monitores de computadores e TVs com a tecnologia de tubos de raios catódicos (CRT) não é simples, pois os mesmos contêm metais pesados e há poucas alternativas de reciclagem estabelecidas, o que gera um passivo ambiental ainda sem solução. O CRT corresponde a 80% do peso de um monitor de computador e é constituído por três tipos de vidro, com diferentes composições. A relação aproximada (em % peso) é: 65% painel, 30% funil e 5% pescoço. Entre os diferentes vidros dos quais é fabricado os CRTs, o painel tem altas porcentagens de óxidos de metais alcalino e alcalino-terrosos e assim grande potencial para ser aproveitado como substituto de fritas na formulação de esmaltes cerâmicos. Uma vantagem adicional é o fato de que os metais pesados são estabilizados na forma de óxidos, tendo a mínima dissolução após a sinterização e vitrificação. Neste trabalho as composições químicas do vidro de painel de CRT e da frita foram caracterizadas pela técnica de FRX e ICP-AES. Depois os valores do coeficiente de expansão térmica e a viscosidade como função da temperatura foram calculados usando modelos empíricos que relacionam essas propriedades com a composição química do vidrado, através do software e banco de dados SciGlass®. Substituições parciais de frita por vidro de painel de CRT foram experimentalmente testadas na formulação de um esmalte transparente típico. Suspensões com 10 a 40% em peso de vidro de painel de CRT como substituto da frita tradicional foram preparadas e aplicadas sobre a superfície de substratos de argila conformados por prensagem. Subsequentemente, as placas foram queimadas seguindo um ciclo térmico similar ao utilizado industrialmente. Os valores do coeficiente de expansão térmica foram caracterizados por dilatometria. A viscosidade do esmalte foi medida a temperaturas elevadas (viscosidades baixas). A cor e a transparência dos esmaltes após a queima foram caracterizadas por colorimetria. Em uma análise comparativa, a substituição de 20% em peso de frita por vidro de painel de CRT resultou em revestimentos com propriedades equivalentes as de esmaltes comerciais. / The current problem of disposal of electronic waste stimulates research aiming at the reuse of this type of waste in the manufacture of new products or existing processes. The disposal of computer monitors and televisions based on the technology of cathode ray tube (CRT) is not simple, since they contain heavy metals and there are few recycling alternatives nearby the consumer center, generating an unsolved environmental liability. The CRT corresponds to approximately 85 wt% of a computer monitor, and is composed by three silicate glasses with different compositions, in the approximate proportions (wt%): 65% panel, 30% funnel and 5% neck glass. Among the different glasses of which the CRT\'s are made, the panel has higher percentages of alkali and alkaline earth metal oxides, which thus give them potential to be used as frits substitute in the formulation of ceramic glazes. An additional advantage is the fact that these heavy metals are stabilized in the form of oxides, presenting minimal dissolution after sintering and vitrification. In the present work, the chemical compositions of a CRT\'s panel glass and glaze frits were characterized by XRF and ICP-AES. Then, the value of thermal expansion coefficients and viscosity were calculated as a function of temperature using empirical models that relate such properties with the glass chemical composition, aided by the SciGlass software. The partial replacement of frits for CRT\'s panel glass was experimentally tested in the composition of a typical transparent ceramic glaze. Aqueous suspensions containing 10 to 40 wt% of CRT\'s panel glass as a substitute for the traditional frit were prepared and applied on the surface of substrates formerly obtained by pressing a clay raw material into plates. Subsequently, the plates were fired following a thermal treatment similar to the used industrially. The resulting thermal expansion coefficients were characterized by dilatometry. The glaze viscosity was measured at high temperatures (low viscosities). The color and transparency of the glazes after firing were characterized by colorimetry. In a comparative analysis, the substitution of 20 wt% of frit by CRT\'s panel glass resulted in ceramic tiles with properties equivalent to those of the commercial glazes.
253

Paredes exteriores de edifícios em pano simples : fundamentos, desempenho e metodologia de análise

Alves, Sérgio Gabriel Quádrio da Mota January 2001 (has links)
Tese de mestrado. Engenharia Civil. Faculdade de Engenharia. Universidade do Porto. 2001
254

Influência da deformação de lajes fungiformes no comportamento de revestimentos cerâmicos de piso

Gonçalves, Nuno Eduardo Santos January 2012 (has links)
Tese de Mestrado Integrado. Engenharia Civil (Construções Civis). Faculdade de Engenharia. Universidade do Porto. 2012
255

Análise exigencial comparada de soluções de coberturas leves de armazéns e edifícios industriais

Carreiro, António Luís Fonseca January 2011 (has links)
Mestrado Integrado. Engenharia Civil - Especialização em Construções. Faculdade de Engenharia. Universidade do Porto. 2011
256

Efeito autorreparador em primer carregado com inibidor de corrosão encapsulado em haloisita. / Self-healing effect of primer loaded with corrosion inhibitor encapsulated in halloysite.

Carvas, Gabriela Silva Ferreira 14 June 2019 (has links)
O objetivo deste trabalho é avaliar o efeito autorreparador de um primer alquídico base solvente (SB) e um primer acrílico base água (WB) aditivados com nanocontainers de haloisita carregados com inibidor de corrosão dodecilamina (DDA) aplicados em aço carbono. O efeito inibidor da dodecilamina foi avaliado através de ensaios eletroquímicos de espectroscopia de impedância eletroquímica (EIS) em diferentes condições, sendo verificada que a sua eficiência aumenta em meio ácido. Com o intuito de aumentar o lúmen da haloisita, gerando mais capacidade de carregamento de inibidor, a haloisita foi tratada com ácido sulfúrico 2 mol/L por 6 h a 55 °C. A haloisita tratada foi caracterizada através de análises termogravimétricas (TGA) e microscopia eletrônica de varredura (MEV). Em seguida, a dodecilamina foi carregada em haloisita tratada, através da técnica de pulso de vácuo. A cinética de liberação do inibidor de dentro da haloisita foi estudada através da técnica de EIS, onde foi constatada que a sua atuação é dependente do pH, com maior velocidade de liberação em pH 2. Os nanocontainers foram adicionados em um primer alquídico base solvente e um primer acrílico base água para a avaliação da resistência à corrosão dos sistemas através de espectroscopia de impedância eletroquímica (EIS), técnica de varredura com eletrodo vibratório (SVET) e ensaios acelerados de corrosão em câmara de névoa salina (SSC). A aderência dos dois sistemas foi avaliada através do ensaio de aderência por tração (pull-off). Para os dois sistemas avaliados foi possível verificar o efeito autorreparador, porém ele não foi tão longo, provavelmente devido à baixa eficiência no carregamento da dodecilamina na haloisita. A análise de custo da haloisita carregada com dodecilamina mostrou a necessidade de otimização dos processos de carregamento a fim de viabilizar o projeto na indústria de tintas. / The aim of this work is to evaluate the self-healing effect of a solvent based (SB) alkyd primer and a water based (WB) acrylic primer loaded with dodecylamine (DDA) corrosion inhibitor encapsulated in halloysite nanocontainers on carbon steel. The inhibitor effect of dodecylamine was evaluated by electrochemical impedance spectroscopy (EIS) under different conditions, and it was verified that its efficiency increases in acid medium. To enlarge halloysite lumen and increase its loading capacity, halloysite was treated with 2 mol/L sulfuric acid for 6 h at 55 °C. Halloysite before and after treatment was characterized by thermogravimetric analysis (TGA) and scanning electron microscopy (SEM). Thereafter, the dodecylamine was loaded into treated halloysite by the vacuum pulse technique. The release kinetics of the inhibitor from within halloysite nanotubes were studied through the EIS technique where it was found that the action of halloysite is pH-dependent, with a higher release kinetics at pH 2. The nanocontainers were loaded in a solvent based alkyd primer and a water based acrylic primer for the evaluation of the corrosion resistance of the systems through electrochemical impedance spectroscopy (EIS), scanning vibration electrode technique (SVET) and accelerated corrosion tests in a salt spray chamber (SSC). The adhesion of the two systems was evaluated through the pull-off adhesion test. For the two systems evaluated, it was possible to verify the self-healing effect, but this effect was not long, probably due to the low loading efficiency of dodecylamine in halloysite nanotubes. The cost analysis of halloysite loaded with dodecylamine showed that the loading process needs an optimization in order to make this project feasible in the coating industry.
257

Análise do substrato e revestimento de próteses de quadril fabricadas em titânio puro e liga Ti-6Al-4V. / Substrate analysis and coating of hip prostheses made of pure titanium and Ti-6Al-4V alloy.

DONATH, Katia Shimabukuro. 16 April 2018 (has links)
Submitted by Johnny Rodrigues (johnnyrodrigues@ufcg.edu.br) on 2018-04-16T19:14:07Z No. of bitstreams: 1 KATIA SHIMABUKURO DONATH - DISSERTAÇÃO - PPG-CEMat 2014..pdf: 2790645 bytes, checksum: b24d34b39a32402a89c30625e71e1979 (MD5) / Made available in DSpace on 2018-04-16T19:14:07Z (GMT). No. of bitstreams: 1 KATIA SHIMABUKURO DONATH - DISSERTAÇÃO - PPG-CEMat 2014..pdf: 2790645 bytes, checksum: b24d34b39a32402a89c30625e71e1979 (MD5) Previous issue date: 2014-10-27 / Revestimentos porosos metálicos têm sido utilizados nas próteses ortopédicas de quadril para promover a fixação biológica da prótese ao osso. Dentre os materiais mais utilizados para fabricação da prótese e do revestimento estão o titânio comercialmente puro e a liga de titânio Ti-6Al-4V. O titânio e suas ligas apresentam alotropia, sendo suas características e propriedades influenciadas por dois fatores principais: composição química e microestrutura. As características de espessura, porosidade, tamanho de poros e interconectividade dos poros no revestimento são importantes para que haja a melhor condução do crescimento ósseo e fixação da prótese. Têm sido reportados na literatura diferentes mecanismos de falha de próteses de quadril em decorrência do revestimento depositado na prótese. Neste trabalho foram identificados 32 normas técnicas e documentos relacionadas ao material, a forjados e a pós metálicos para revestimento de Ti cp e liga de Ti-6Al-4V, além de normas de avaliação do revestimento e guias, alguns com critérios de aceitação, outros não. Na norma ABNT NBR 15628-4 foi verificada inconsistência nos requisitos microestruturais alfa case. Normas técnicas foram comparadas e relacionadas com dados da literatura, pontos críticos foram relacionados ao revestimento poroso metálico, métodos de produção, seus efeitos no substrato de Ti-6Al-4V e características do revestimento poroso. Foram avaliados 8 produtos comercializados no Brasil, considerando o Registro Anvisa, avaliação laboratorial do substrato e do revestimento. No substrato, a composição química foi determinada por Espectroscopia de emissão ótica. A microscopia Ótica (MO) foi utilizada para avaliação microestrutural do substrato e para avaliação estereológica do revestimento. Quanto à composição química do substrato, foram identificados 2 componentes fabricados em Ti cp e 6 em liga Ti-6Al-4V, sendo detectada divergência entre a informação do Registro Anvisa e o produto avaliado. Na avaliação microestrutural do substrato a maior incidência de problemas ocorreu nos produtos fabricados por sinterização, de fabricantes estrangeiros, sendo que 50% dos produtos em liga Ti-6Al-4V apresentaram microestruturas com fase alfa contínua no contorno de grão beta, prejudicial à resistência à fadiga e corrosão do produto, sendo possível a associação com processamento a temperaturas maiores que a temperatura beta transus. Na avaliação da espessura do revestimento todas as amostras de fabricantes estrangeiros tiveram maiores espessuras que a dos fabricantes nacionais, sendo que não foi verificada espessura maior que 500µm entre os nacionais. É possível concluir que as microestruturas são afetadas pelos processos térmicos e que essas precisam de um maior controle, regulamentação e fiscalização para o fornecimento de produtos mais seguros e eficazes, sugerindo a criação de um regulamento específico que reúna de forma clara e concisa as características necessárias para o produto final. / Metallic porous coatings have been used on hip orthopedic prostheses to promote ingrowth of bone into the porous coating prostheses. Among different materials used to manufacture hip prostheses and coatings are titanium materials. Mostly used and available are commercially pure titanium and Ti-6Al4V alloy. Titanium and its alloys are allotrope. Its characteristics are influenced by two principal factors: chemical composition and microstructure. Thickness, porosity, pore size e interconnectivity between pores and coating are important for the bone growth and prosthesis fixation. Different mechanism of hip prosthesis failures in result of the coating placed on the prosthesis have been reported in the literature. In this thesis various technical standards for Titanium commercially pure and Ti-6Al-4V were identified. They are related to the material, the forging and metallic powders for coatings, Furthermore, evaluation methods for coating and industry guidelines, some with acceptance criteria, some without, were found. Within the standard ABNT NBR 15628-4 inconsistencies regarding the required microstructures were found. Technical standards were compared and linked to data from the literature. Critical points related to porous metallic coating, production methods, its effects on Ti-6Al-4V substrate and characteristics of porous coatings. 8 in Brazil commercially available products were evaluated considering their registration at ANVISA and analysis of their coatings in a lab. The chemical composition of the substrate was determined by optical emission spectroscopy. Optical microscopy was used to evaluate the microstructure of the substrate and for stereological analysis of the coating. Chemical composition analyses of the substrate pointed 2 components made of Titanium commercially pure and 6 made of Ti-6Al-4V. One sample had results of substrate according Ti-6Al-4V alloy besides registration information at ANVISA described substrate made of Ti commercially pure. Regarding the microstructural analysis of the substrate, the majority of problems occurred with products made by sintering and by foreign producers. 50% of products made by Ti-6Al-4V presented microstructures with continuous alpha phase on the beta grain boundaries. Therefore it can be concluded that they were processed at temperatures higher than beta transus temperatures. Analyzing the thickness of the coating, all samples from foreign producers had a bigger thickness than any national product. No national product had a thickness bigger than 500µm. Therefore it is possible to conclude that the microstructure was affected by the thermic processes and that those need better controls, regulation and surveillance in order to supply more secure and effective products.
258

Avaliação da perda de massa de revestimento duro depositado por soldagem com arame tubular de liga FeCrC-Ti

Colaço, Fernando Henrique Gruber 17 June 2013 (has links)
Fundação Araucária / Neste trabalho estudou-se a perda de massa de revestimento duro aplicado pelo processo de soldagem com arame tubular com a variação de energia de soldagem, gás de proteção e número de camadas do revestimento. Com arame tubular autoprotegido de liga Fe-Cr-C-Ti foram depositados cordões simples sobre chapas de aço ao Carbono AISI 1020 para a análise da morfologia, diluição e dureza. Para a análise da perda de massa foram depositados cordões sobreposto formando camadas de revestimento. Por meio de análise de imagem foram feitas medições do reforço, largura e penetração do cordão de solda e, por consequência, obtida a diluição. Foram realizadas medições de dureza na secção transversal dos cordões e na superfície dos corpos de prova de desgaste. Abrasômetro tipo roda de borracha foi usado para determinar a perda de massa dos revestimentos. Os revestimentos apresentaram microestrutura martensítica e austenita retida com carbonetos finamente dispersos na matriz. Os principais fatores que contribuíram para o aumento na perda de massa foram as trincas devido a maior taxa de resfriamento das amostras depositadas com baixa energia de soldagem, a diluição na primeira camada de todas as amostras também contribuíram para o aumento na perda de massa. As menores perdas de massa foram dos revestimentos de duas e quatro camadas depositados com alta energia de soldagem. A fração volumétrica de carbonetos de Titânio contribuíram para a diminuição do caminho livre médio entre as partículas de carbonetos aumentando a resistência ao desgaste dos revestimentos. / In this work we have studied the mass loss of hardfacing applied by flux cored arc welding. Heat input, shielding gas and number of layers coating. Were changed to application of Fe-Cr-Ti-C self-shielded tubular wire. Single beads were deposited on plates of carbon steel AISI 1020 to analyze the morphology, hardness and dilution. For the analysis of mass loss were deposited beads forming overlapped layers coatings. By means of image analysis measurements were made of the reinforcement, width and penetration and, consequently, the dilution obtained. Hardness measurements were performed on cross-section of the beads and the surface of the specimens of wear. Rubber wheel abrasion tester was used to access the mass loss of coatings. The coatings had retained austenite and martensite microstructure with carbides finely dispersed in the matrix. The main factors that contributed to the increase in mass loss were the cracks due to higher cooling rate of the samples deposited with low heat input, the dilution in the first layer of all samples also contributed to the increase in mass loss. The smallest mass losses were those deposited coatings with high heat input the second and fourth layer, the samples AC2, AC4 and AS2. The volume fraction of titanium carbides contributed to the decrease in the mean free path between the particles of carbides increase the wear resistance of the coatings.
259

Influência de diferentes pilares e materiais de recobrimento estético na manutenção da pré-carga do parafuso de retenção de coroas implantosuportadas

Delben, Juliana Aparecida [UNESP] 23 March 2009 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:58Z (GMT). No. of bitstreams: 0 Previous issue date: 2009-03-23Bitstream added on 2014-06-13T18:58:13Z : No. of bitstreams: 1 delben_ja_me_araca.pdf: 1525895 bytes, checksum: 08b0efeaeab10edf292abba40231b759 (MD5) / A longevidade das próteses e implantes é dependente da adequada adaptação entre os componentes bem como da distribuição favorável de forças às estruturas de suporte. O afrouxamento do parafuso de retenção é uma falha mecânica comumente observada devido à redução da pré-carga gerada no parafuso de retenção, responsável pela manutenção da estabilidade da união parafusada e resistência às forças que tendem a separar os componentes. O objetivo do estudo foi avaliar a influência de diferentes pilares e materiais de recobrimento estético na manutenção da pré-carga do parafuso de retenção de coroas implantosuportadas, submetidos a sucessivos reapertos e ciclagem mecânica. Foram confeccionadas 60 coroas de acordo com os grupos de estudo (n=12): Grupo I - pilares Gold UCLA fundidos em liga de ouro para obtenção de coroas metalocerâmicas, Grupo II - pilares Gold UCLA fundidos em liga de ouro para obtenção de coroas metaloplásticas, Grupo III – pilares do tipo UCLA fundidos em liga de titânio para obtenção de coroas metalocerâmicas, Grupo IV – pilares do tipo UCLA fundidos em liga de titânio para obtenção de coroas metaloplásticas, Grupo IV - pilares de zircônia obtidos pelo sistema CAD/CAM (computer-aided design/computer-aided manufacturing) para obtenção de coroas cerâmicas. As coroas foram unidas a implantes de hexágono externo por meio de parafuso de retenção quadrado de ouro com torque de inserção de 35 Ncm e submetidas à ciclagem mecânica com aplicação de carregamento vertical dinâmico de 50N a uma freqüência de 2Hz. Valores de destorque foram mensurados antes da ciclagem mecânica e após cada período de 1x105 ciclos seguido de reaperto com 35 Ncm de modo a completar 1x106 ciclos. Mensurações da desadaptação vertical na interface pilar-implante foram realizadas através de estereomicroscopia inicialmente e ao final da... / The longevity of prostheses and implants depends on fit betweenn components as well as adequate forces distribution to supporting structures. Retaining screw loosening is a commom mechanical complication due to preload reduction that provides joint stability and resistance to separating forces. The aim of this study was to evaluate the influence of different abutments and veneering materials on preload maintenance of retaining screw of implant-supported crowns submitted to repeated tightening and mechanical cycling. Sixty crowns were obtained according to the groups (n=12): Group I – Gold UCLA abutment cast in gold allow with ceramic vennering, Group II – Gold UCLA abutment cast in gold alloy with resin veneering, Group III – UCLA abutment cast in titanium with ceramic veneering, Group IV – UCLA abutment cast in titanium with resin veneering, and Group V – zirconia abutment obtained by CAD/CAM (computer-aided desing/computer-aided manufacturing) system with ceramic veneering. The crowns were attached to external hexagon implants by gold retaining screws with insertion torque of 35Ncm. The replicas were submitted to mechanical cycling with vertical dinamic loading of 50N at 2Hz. Detorque measurements were performed initially and after each period of 1x105 cycles followed by retightening of retaining screw with 35Ncm until 1x106 cycles. Measurements of vertical misfit on abutment-implant interface were performed through estereomicroscopy initially and after mechanical cycling. Data were submitted to analysis of variance, Fisher’s exact test, paired t test, Student’s t-test and Pearson correlation (P<.05). All detorque measurements were lower than insertion torque of 35Ncm. There was statistically significant difference among the 5 groups (P<.05) for detorque values obtained initially and after mechanical cycling. However, there was no statistically significant difference... (Complete abstract click electronic access below)
260

Análise numérica e experimental da fadiga termomecânica em argamassas colantes no sistema de revestimento cerâmico / Numerical and experimental analysis of thermomechanical fatigue in adhesive mortars in ceramic coat system

Uchôa, João Carlos Barleta 04 November 2015 (has links)
Tese (doutorado)—Universidade de Brasília, Faculdade de Tecnologia, Departamento de Engenharia Civil e Ambiental, 2015. / Submitted by Fernanda Percia França (fernandafranca@bce.unb.br) on 2016-04-29T15:08:48Z No. of bitstreams: 1 2015_JoãoCarlosBarletaUchôa.pdf: 3846326 bytes, checksum: 2b2b3ba5f4d48b6a1c1379d1c7ab9da9 (MD5) / Approved for entry into archive by Raquel Viana(raquelviana@bce.unb.br) on 2016-05-04T22:51:47Z (GMT) No. of bitstreams: 1 2015_JoãoCarlosBarletaUchôa.pdf: 3846326 bytes, checksum: 2b2b3ba5f4d48b6a1c1379d1c7ab9da9 (MD5) / Made available in DSpace on 2016-05-04T22:51:47Z (GMT). No. of bitstreams: 1 2015_JoãoCarlosBarletaUchôa.pdf: 3846326 bytes, checksum: 2b2b3ba5f4d48b6a1c1379d1c7ab9da9 (MD5) / Uma das principais patologias do sistema de revestimento cerâmico é o destacamento de peças cerâmicas por fissuração do material de fixação das peças. Há um desconhecimento, por parte dos projetistas e normas técnicas, do real comportamento dos materiais dos sistemas de revestimentos sob ação de intempéries, como a variação de temperatura ao longo do dia. Os deslocamentos gerados pela variação da temperatura produzem tensões no interior do sistema de revestimento. A diferença no comportamento térmico e higrométrico dos materiais das camadas do sistema de revestimento origina deformações e tensões diferentes entre essas camadas. Este trabalho utiliza uma abordagem experimental e numérica para o estudo do comportamento da fadiga das argamassas colantes industrializadas ACII e ACIII. Tais argamassas compõem o sistema de revestimento cerâmico sob carregamento cíclico de tensões. Na abordagem experimental, foram realizados ensaios de caracterização para identificar a resistência à tração e à compressão, a consistência da pasta e o módulo de elasticidade das argamassas ACII e ACIII. Em seguida, foi proposta uma metodologia de ensaio de fadiga das argamassas ACII e ACIII sob tração e compressão axiais. Os resultados dos ensaios de fadiga permitiram traçar a Curva S-N de Wöhler e obter o limite de resistência à fadiga das argamassas ACII e ACIII. Na abordagem de análise numérica, utilizou-se o método dos elementos finitos para se propor uma metodologia para a avaliação das tensões geradas no sistema de revestimento cerâmico submetido a um transiente térmico conservador representativo de Brasília, DF. Com os valores das tensões alternadas obtidos das análises numéricas, é possível, com a metodologia apresentada, avaliar a resistência à fadiga das argamassas colantes industrializadas ACII e ACIII em sistema de revestimento cerâmico de fachadas. / One of the main pathologies of the ceramic coating facades is the detachment of ceramic tiles by cracking of the material for fixing the tiles. On the part of designers and technical standards, there is a lack of knowledge of the real behavior of the materials in coatings systems exposed to hazardous weather conditions like the everyday variation of weather temperature. The displacements generated by temperature variations produce stresses within the ceramic coating system. The difference in the thermal and hygrometric behavior of the materials in the different layers of the coating system affords different deformations and stresses between those layers. This work uses experimental and numerical investigations to study the fatigue behavior of industrialized adhesive mortars known as ACII and ACIII. Those mortars compose the ceramic coating system subjected to cyclic stresses. In the experimental investigation, testes were undertaken to characterize traction and compression resistance, consistency, and modulus of elasticity of ACII and ACIII mortars. Afterwards, a methodology for fatigue testing of mortars ACII and ACIII under axial traction and compression was proposed. The fatigue test results allowed plotting the S-N Wöhler curve and get the fatigue resistance limit of mortars ACII and ACIII. In the numerical analysis approach, the finite element method was used to set a proposed methodology for evaluating the stresses generated in the ceramic coating system under a conservative thermal transient typical of Brasilia, DF. With the values of the alternating stresses obtained by numerical analysis, it was possible, with the proposed methodology, to evaluate the fatigue resistance of the industrialized adhesive mortars ACII and ACIII in ceramic coating facades.

Page generated in 0.105 seconds