• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 24
  • 1
  • Tagged with
  • 25
  • 13
  • 11
  • 9
  • 8
  • 8
  • 8
  • 7
  • 6
  • 6
  • 6
  • 5
  • 4
  • 4
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Adaptação Fisiológica de idosos com sepse: diagnósticos e intervenções de enfermagem / Physiological adaptation of elderly patients with sepsis: nursing diagnoses and interventions.

Oliveira, Danielle Samara Tavares de 18 March 2013 (has links)
Made available in DSpace on 2015-05-08T14:47:32Z (GMT). No. of bitstreams: 1 ArquivoTotalDanielleSamara.pdf: 1565154 bytes, checksum: 99bd7bd92e97b2084e8fb93b433025fa (MD5) Previous issue date: 2013-03-18 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES / Introduction: Sepsis is a serious disease, with high morbidity and mortality, especially when it affects the elderly, because, as a result of the aging process, he may have worse prognosis in relation to the general population. Objectives: Check, in the light of specific components of the mode of physiological adaptation of Callista Roy, adaptive problems of elderly patients with sepsis admitted to intensive care unit, related to these components, as well as draw up a proposal for nursing care containing diagnoses, results and interventions for these patients. Method: This is a cross-sectional study with a quantitative approach, developed in the Intensive Care Unit of a hospital school, between February and June 2012. The sample was composed of 25 elderly patients with medical diagnosis of sepsis, severe sepsis or septic shock. Data collection was subsidized by a structured instrument, based on the Theory of Callista Roy, using the technique of systematic observation and physical examination, in addition to record information from the medical record. It is noteworthy that, in the research process were respected ethical principles laid down in Resolution 196/96. The data were analyzed by statistical treatment of descriptive and discussed in the light of the relevant literature. For the construction of the diagnoses and nursing interventions, were used, respectively, the Classifications North American Nursing Diagnosis Association International and Nursing Interventions Classification. Results: In the interpretation of the findings, it was found that the septic picture occurred not only in the elderly more long-lived, but in the elderly young, with greater incidence between males and those with low education and low socioeconomic level. The lowest period of hospitalization was associated with the highest rates of mortality, which indicates great risk of death in these patients, when the clinical picture evolves for sepsis to septic shock. The main problems adaptive found were related to the components oxygenation and disposal. We identified 28 nursing diagnoses in group researched and obtained an average of 19.6 diagnoses per elderly person. Among the most frequent, stood out 22 diagnoses that have reached a frequency greater than or equal to 50 %. The most incidents were: spontaneous ventilation impaired, impaired gas exchange, imbalanced nutrition: less than the body needs, self-care deficit: bath, intimate hygiene and feeding and the risk of unstable blood glucose. Thus, for these nursing diagnoses, were drawn up results and nursing interventions that could subsidize the decision-making process of the nurse, which contributes to solve or minimize such diagnoses. Conclusion: The data obtained by means of this research suggest that nursing care is essential and a priority for the elderly in septic process, especially when based on Adaptation Model of Roy. Considering this, it was drawn up a plan of care with a view to promoting a care directed at the needs of elderly septic that may help to reduce/minimize the situations of physiological adaptation ineffective. / Introdução: A sepse é uma doença grave, de elevada morbimortalidade, especialmente quando acomete o idoso, pois, em decorrência do processo de envelhecimento, ele pode apresentar pior prognóstico em relação à população geral. Objetivos: Verificar, à luz de componentes específicos do Modo Fisiológico de Adaptação de Callista Roy, problemas adaptativos de idosos com sepse internados em Unidade de Terapia Intensiva, relacionados a esses componentes, assim como elaborar uma proposta de assistência de enfermagem contendo diagnósticos, resultados e intervenções para esses pacientes. Método: Trata-se de um estudo transversal, com abordagem quantitativa, desenvolvido em Unidade de Terapia Intensiva de um hospital-escola, entre fevereiro e junho de 2012. A amostra foi composta por 25 idosos com diagnóstico médico de sepse, sepse grave e ou choque séptico. A coleta de dados foi subsidiada por um instrumento estruturado, fundamentado na Teoria de Callista Roy, utilizando-se a técnica de observação sistemática e de exame físico, além de registro de informações do prontuário. Ressalta-se que, no processo de pesquisa, foram respeitados os princípios éticos previstos na Resolução 196/96. Os dados foram analisados mediante tratamento estatístico do tipo descritivo e discutidos à luz da literatura pertinente. Para a construção dos diagnósticos e das intervenções de enfermagem, foram utilizadas, respectivamente, as Classificações North American Nursing Diagnosis Association International e a Nursing Interventions Classification. Resultados: Na interpretação dos achados, verificou-se que o quadro séptico ocorreu não apenas em idosos mais longevos, mas nos idosos jovens, com maior incidência entre o sexo masculino e naqueles de baixa escolaridade e baixo nível socioeconômico. O menor período de hospitalização relacionou-se às maiores taxas de mortalidade, o que indica grande risco de óbito nesses pacientes, quando o quadro clínico evolui de sepse para choque séptico. Os principais problemas adaptativos encontrados estiveram relacionados aos componentes oxigenação e eliminação. Foram identificados 28 diagnósticos de enfermagem no grupo pesquisado e obtida uma média de 19,6 diagnósticos por idoso. Dentre os mais frequentes, destacaram-se 22 diagnósticos que atingiram uma frequência maior ou igual a 50%. Os mais incidentes foram: ventilação espontânea prejudicada, troca de gases prejudicada, nutrição desequilibrada: menos que as necessidades corporais, déficit de autocuidado: banho, higiene intima e alimentação e risco de glicemia instável. Assim, para esses diagnósticos de enfermagem, foram elaborados resultados e intervenções de enfermagem que poderão subsidiar a tomada de decisão do enfermeiro, o que contribui para resolver ou minimizar tais diagnósticos. Conclusão: Os dados obtidos por meio desta investigação apontam que o cuidado de enfermagem é essencial e prioritário para o idoso em processo séptico, especialmente quando fundamentado no Modelo de Adaptação de Roy. Considerando isso, foi elaborado um plano de cuidados com vistas a promover um cuidado direcionado às necessidades de idosos sépticos, que poderá contribuir para reduzir/minimizar as situações de adaptação fisiológica ineficaz.
12

Avaliação de métodos para testes de suscetibilidade in vitro de enxaguantes bucais frente a espécies do gênero Candida / Evaluation of methods for in vitro susceptibility testing of mouthwashes against species of the gender Candida

Rodrigues, Manuela Luiza Toti 08 December 2008 (has links)
A candidíase é uma infecção fúngica oportunista freqüente, causada por leveduras do gênero Candida. A utilização de anti-sépticos como medida complementar na higiene oral é cada vez mais difundida. Sendo assim, é de grande importância a avaliação das metodologias que são utilizadas para avaliação da atividade antifúngica. A avaliação in vitro da sensibilidade de leveduras a anti-sépticos tem sido pouco relatada e os resultados nem sempre são concordantes, pois as metodologias são divergentes. O objetivo desse estudo foi avaliar três metodologias: macro e microdiluição em caldo e difusão em ágar por meio de poços, com utilização dos meios de cultura RPMI 1640 e Mueller-Hinton para suscetibilidade dos anti-sépticos bucais Listerine®, Malvatricin® Dentes Sensíveis, Noplak®Max, Oral B®, Periogard®, Plax® e Reach® frente a C. albicans ATCC 64548, C. glabrata ATCC 90030, C. krusei ATCC 6258, C. parapsilosis ATCC 22019 e C. tropicalis ATCC 750. Em relação à comparação das concentrações inibitórias mínimas de cada meio de cultura, os índices kappa foram bons ou excelentes (0,73 a 1,00). Na metodologia da difusão em ágar o coeficiente de correlação de concordância entre os resultados dos meios de cultura também foi excelente (0,95 a 0,99). Concluímos que ambos os meios de cultura podem ser utilizados na avaliação da suscetibilidade de anti-sépticos bucais frente espécies de Candida, pois apresentaram índices de concordância e correlação de bom à excelente. Quanto à correlação entre as metodologias de macro e microdiluição, o kappa foi excelente (1,00) para todas as cepas no meio Mueller-Hinton e variou de 0,42 a 0,72 (bom a excelente) no meio RPMI-1640. As CIMs geradas pela macro e microdiluição em caldo são concordantes possibilitando a utilização de ambas as metodologias na avaliação de anti-sépticos bucais, no entanto a microdiluição detectou a ação inibitória de anti-sépticos voláteis em menores concentrações. A utilização da difusão em ágar é discutível visto que os anti-sépticos voláteis Listerine® e Malvatricin® não apresentaram atividade inibitória nesta metodologia. Todos os anti-sépticos avaliados apresentaram atividade fungistática e fungicida in vitro pelas metodologias de diluição frente a cepas ATCC de Candida quando avaliado na formulação disponibilizada pelos fabricantes. Os anti-sépticos bucais Oral B® e Periogard® apresentaram ações inibitórias (CIM) e fungicidas (CFM) de 1,25% para todas as cepas, meios e metodologias. O Noplak® e o Plax®, CIM e CFM variando de 1,25% a 2,5% para todas as cepas, meios e metodologias. Os anti-sépticos Listerine® e Malvatricin® apresentaram CIM de 5% a 50% e CFM de 5% a 100% dependendo do meio e metodologia. O anti-séptico Reach® apresentou CIM e CFM variando de 1,25% a 50% dependendo da cepa avaliada. Estudos com maior número de isolados, maior diversidade de espécies, concentrações intermediárias de anti-séptico e resultados interlaboratoriais poderão contribuir na padronização de métodos para avaliação de anti-sépticos bucais. / Candidosis is a frequent opportunistic fungal infection caused by yeasts of the gender Candida. The use of mouthwashes as a preventive measure in oral hygiene has been more and more diffused. Therefore it is of great importance the evaluation of the methodologies that are used on the antifungal evaluation. The in vitro evaluation of yeast susceptibility to mouthwashes has been little reported and the results are not always in agreement. The goal of this study was to evaluate three methodologies: broth macro and microdilution and agar well diffusion, using the media RPMI 1640 and Mueller-Hinton on the susceptibility of the mouthwashes Listerine®, Malvatricin® Dentes Sensíveis, Noplak®Max, Oral B®, Periogard®, Plax® e Reach® against C. albicans ATCC 64548, C. glabrata ATCC 90030, C. krusei ATCC 6258, C. parapsilosis ATCC 22019 e C. tropicalis ATCC 750. The kappa indexes for the comparison between the minimal inhibitory concentrations obtained with each culture medium were good to excellent (0,73 to 1,00). On the agar well diffusion method, the concordance correlation coefficients between the results obtained with the different media were also excellent (0,95 to 0,99). We concluded that both culture media can be used to evaluate the susceptibility of mouthwashes against species of Candida because they have concordance and correlations that go from good to excellent. The kappa indexes for the correlation between the broth macro and microdilution methodologies were excellent (1,00) for all the isolates in the Mueller-Hinton media and varied from 0,42 to 0,72 (good to excellent) with RPMI 1640. The MICs generated by broth macro and microdilution agree which makes it possible to use both methodologies on the evaluation of mouthwashes; however the microdilution detects the inhibitory action of volatile mouthwashes at smaller concentrations. The use of the agar well diffusion method is not advised since the volatile mouthwashes Listerine® and Malvatricin® have not presented inhibitory action in that methodology. All the evaluated mouthwashes presented fungistatic and fungicide activity at the formulation available in the market. The mouthwashes Oral B® and Periogard® presented MICs and MFCs of 1,25% for all strains, methodologies and media. Noplak® and Plax®, MIC and MFC that ranged from 1,25% to 2,5% for all strains, methodologies and media. The mouthwashes Listerine® and Malvatricin® MICs ranged from 5% to 50% and MFCs from 5% to 100% depending on media and methodology. The mouthwash Reach® presented MICs and MFCs ranging from 1,25% to 50% depending on the strain evaluated. Studies with a higher number of strains, bigger variety of species, intermediary concentrations of mouthwashes and interlaboratory results can contribute to the standardization of methods to evaluate mouthwashes.
13

Impacto do lançamento de lodo de tanques/fossas sépticas em estação de tratamento de esgoto com reator anaeróbio de fluxo ascendente e manta de lodo (UASB) / Impact of sludge disposal of septic tanks on wastewater treatment plant with upflow anaerobic sludge blanket (UASB)

Gonçalves, Camila do Prado 31 October 2008 (has links)
Neste trabalho avaliou-se o desempenho de um reator anaeróbio de fluxo ascendente e manta de lodo (UASB) no tratamento combinado de esgoto sanitário com o lançamento de lodo proveniente de tanques sépticos. O estudo foi desenvolvido em escala plena na Estação de Tratamento de Esgoto (ETE) do Campus I da Universidade de São Paulo (USP) em São Carlos-SP. Foram utilizados dois reatores UASB com 18,8 m³ cada, um reator (UASB I) com função de controle e o outro reator (UASB II) no qual foi descarregado o lodo séptico. A pesquisa foi dividida em duas etapas: a primeira compreendeu o início de operação e o monitoramento dos reatores e, da segunda fez parte os ensaios de lançamento de lodo séptico no sistema. A partida foi efetuada sem utilização de inóculo e os reatores foram operados com tempo de detenção hidráulica médio (TDH) de 8 h, vazão afluente média de 2,35 m³/h e velocidade ascensional de 0,6 m/h. Em seis meses de operação os reatores apresentaram eficiências médias de remoção de DQO nos reatores UASB I e UASB II iguais a 49% e 65%. Quanto à remoção de sólidos os reatores UASB I e UASB II atingiram remoção de 36% e 37% para ST e de 67% e 63% para SST, respectivamente. Após esse período, deu-se início ao estudo que avaliou o impacto do lançamento de lodo séptico no UASB II. Foram realizados três ensaios com diferentes volumes de lodo (1; 3 e 5 m³) descarregados na forma de pulso com vazão média de 5,24 m³/h. Os lodos sépticos utilizados na pesquisa foram coletados por caminhões limpa-fossa e descarregados em um reservatório (15 m³) na ETE para posterior lançamento no reator UASB II. Foram feitas as caracterizações das amostras dos lodos sépticos (coletadas no ato da descarga em cada ensaio), com as quais pôde-se constatar a heterogeneidade da composição desse tipo de resíduo e sua viabilidade de pós-tratamento anaeróbio. Nos ensaios foram realizados monitoramentos temporais logo após a descarga de lodo para acompanhamento da resposta ao pulso de carga imposto. No geral, o reator UASB apresentou capacidade de degradar aproximadamente 2/3 da carga orgânica lançada com o lodo séptico. Os resultados são um indicativo de que a disposição de lodo sépticos em reatores UASB, quando bem programada, é uma solução viável e de grande importância para o tratamento dos resíduos provenientes de tanques/fossas sépticas. / The performance of upflow anaerobic sludge blanket (UASB) in the sanitary wastewater combined treatment with sludge disposal of septic tanks was evaluated in this work. The study was carried out (full scale) in the Wastewater Treatment Plant (WTP) located in campus I of the University of Sao Paulo (USP), city of Sao Carlos, State of Sao Paulo, Brazil. Two UASB reactors were used; volume of each reactor ~ 18,8 m³. UASB I was the control reactor, and UASB II was the reactor in which the septic sludge was disposed. The research was divided in two steps: the first one, which has taken into account the beginning of reactors operation and, the second one, in which occurred the disposal of septic sludge in the reactors. The start-up was carried out without utilization of inoculums. Reactors were operated with an average hydraulic retention time of 8 hours, average influent flow rate of 2.35 m³/h, and upflow velocity of 0.6 m/h. In six months, reactors presented average removal efficiencies of COD in UASB I and UASB II of 48% and 65%, respectively. Concerning to the solid removal, UASB I and UASB II have achieved removal of 36% and 37% for TS, and 67% and 63% for TSS, respectively. After this period of time, the evaluation of disposal impact of septic sludge was started in UASB II. Three essays with different sludge volume (1, 3, and 5 m³) were carried out; sludge volume was disposed in a pulse way with average flow rate of 5.24 m³/h. Septic sludge utilized in the research was collected by clean septic tank trucks, and disposed in a reservoir (volume of 15 m³) in WTP, in order to allow further disposal in the UASB II. By the hand of characterization of septic sludge samples (collected when disposal was carried out), it was possible to verify the heterogeneity about composition of this kind of waste and its availability in terms of anaerobic post-treatment. Temporal monitoring after the sludge disposal was carried out in order to allow the accompaniment of results provided by the pulse. In general, UASB reactor presented capacity in terms of degradation of approximately 2/3 of the organic load disposed with septic sludge. The results are a good indicative that the disposal of septic sludge in UASB reactors is a viable solution, and it is very important for the treatment of wastes from septic tanks.
14

Abordagem farmacocinética/farmacodinâmica (PK/PD) da vancomicina no controle da sepse por patógenos gram-positivos em pacientes queimados críticos pediátricos / Vancomycin pharmacokinetic-pharmacodynamic approach for the control of septic shock caused by gram-positive pathogens in paediatric critical burn patients

Macedo, Vedilaine Aparecida Bueno da Silva 07 November 2017 (has links)
INTRODUÇÃO - OBJETIVO: A vancomicina é um glicopeptídeo de primeira escolha largamente prescrito aos pacientes críticos no tratamento de infecções graves causadas por patógenos nosocomiais Gram-positivos susceptíveis. Os pacientes grandes queimados são considerados pacientes críticos pelas condições metabólicas e importantes alterações fisiopatológicas decorrentes do choque séptico que modificam a farmacocinética da vancomicina. Destaca-se, entretanto que nos pacientes críticos queimados pediátricos essa alteração ocorre em diferente proporção quando comparada aquela reportada para pacientes adultos. Assim sendo, a efetividade desse antimicrobiano é um desafio para a equipe clínica da terapia intensiva, uma vez que a dose empírica nesses pacientes tem fornecido concentrações inferiores às recomendadas, resultando em falha terapêutica pela falta de cobertura do antimicrobiano contra patógenos susceptíveis, CIM ≥1mg/L. O objetivo foi realizar o monitoramento das concentrações plasmáticas de vancomicina seguido da abordagem farmacocinética-farmacodinâmica (PK/PD) a fim de se avaliar a efetividade do regime empírico recomendado ao paciente crítico pediátrico e se realizar o ajuste de dose para erradicação dos patógenos. CASUÍSTICA E MÉTODOS: Incluíram-se 20 pacientes (14M/6F), função renal normal com média de idade 5,95 (4,5-7,4) anos, peso 25,2 (20,5-30)kg, superfície de área queimada total 31,1(25-37)%. Os acidentes foram causados pelo fogo/ combustão por álcool; registrou-se lesão inalatória (12/20) e uso de drogas vasoativas e ventilação mecânica em 13/20 pacientes. Os exames de rotina laboratorial foram realizados diariamente; antes do início da terapia antimicrobiana, colheram-se amostras de sangue no D0 para cultura e realização do teste de susceptibilidade. Os pacientes foram investigados em diferentes seguimentos durante o choque séptico; o regime de dose empírica recomendada pelo CCIH foi prescrito e 3-4 amostras seriadas de sangue (1,5 mL/cada) foram coletadas do CVC no intervalo de dose após a dose diária empírica recomendada e após a individualização da terapia medicamentosa. A quantificação de vancomicina plasmática foi realizada através da cromatografia líquida. Na modelagem PK utilizou-se o programa PK Solutions Noncompartmental Data Analysis versão 2.0. Na abordagem PK/PD e no tratamento estatístico aplicou-se o programa GraphPad Prisma v.5.0. Empregou-se a razão da área sob a curva (ASCss0-24) e concentração inibitória mínima superior a 400 (ASCss0-24/CIM>400) como índice preditivo de efetividade recomendada para o antimicrobiano. Aplicou-se estatística paramétrica com relação aos dados demográficos e laboratoriais, e estatística não paramétrica com relação à dose, concentração plasmática, área sob a curva, constantes farmacocinéticas e efetividade do antimicrobiano. Aplicaram-se nesse estudo os testes paramétricos (ANOVA e Teste T de Student) e não paramétricos (Wilcoxon e Mann Whitney) no programa GraphPad Prisma v.5.0., e o nível de alfa igual ou inferior a 0,05 (P<0,05) foi considerado na significância estatística. RESULTADOS: A dose empírica de vancomicina foi 50 (44-51) mg/kg dia, mediana (quartis, IQ25-75) mostrou que o alvo foi atingido para 85% (17/20) dos pacientes apenas contra cepas sensíveis (CIM&≤1mg/L), ficando desta forma todos os pacientes desprotegidos contra cepas CIM >1mg/L (CIM: 2-4 mg/L). Então, registrou-se alteração de conduta médica relativa à prescrição com aumento da dose diária de vancomicina 94 (85-104) mg/Kg. Esse aumento se mostrou significativo com relação a dose inicial empírica, p<0,05. Após nova estabilização pela terapia dose ajustada, e coletas de sangue no platô, o alvo PK/PD foi alcançado para todos os pacientes, contra patógenos CIM 1mg/L. Entretanto, apenas 5/20 pacientes alcançaram o alvo PK/PD contra cepas susceptíveis CIM: 2mg/L, sendo que nenhum paciente se mostrou coberto contra cepas CIM 4mg/L. CONCLUSÃO: O regime empírico de dose recomendado para a vancomicina não se mostrou efetivo contra os patógenos sensíveis isolados. Concluindo, o controle terapêutico, estudo da farmacocinética e abordagem PK/PD realizado em tempo real possibilitou a alteração precoce de prescrição da vancomicina nos pacientes pediátricos grandes queimados de forma a otimizar a terapia antimicrobiana e o controle das infecções causadas por patógenos hospitalares susceptíveis (CIM ≥1mg/L). / INTRODUCTION- OBJECTIVE: Vancomycin is a first choice glycopeptide largely prescribed to critically ill adult or pediatric patients under therapy of severe infections caused by gram-positive susceptible nosocomial strains. Burn patients have metabolic conditions that change the pharmacokinetics of vancomycin in the treatment of severe infections. Pediatric patients are even more complicated because pharmacokinetic changes are quite different compared to adults, then effective vancomycin dose regimen is a challenge to clinic staff, once the initial dose recommended cannot reach the target against MIC ≥ 1 mg/L strains. Then therapeutic fail with impact on desired outcome. Therefore the rational of study was to apply therapeutic drug plasma monitoring (TDM) in order to identify the pharmacokinetic changes that occur in paediatric burns through PK/PD approach to perform in a real time the dose adjustment required. METHODS - CASUISTRY: Twenty septic burn pediatric patients was investigated after the admission in the Intensive Care Unit of Burns (ICBU) Plastic Surgery Division of HCFMUSP. Vancomycin empiric dose regimen recommended was prescribed 500mg every 6 hours, and patients received one hour drug infusion. Blood sampling was performed after drug infusion at time dose interval (1.5 mL/tube, sodium EDTA): 2nd or 3rd h, 4th, and before the next dose. Vancomycin was quantified by liquid chromatography (LC). Pharmacokinetics was investigated on the basis on one compartment open model by Noncompartmental Data Analysis PK Solutions v 2.0, software. PK/PD approach was based on the ratio of area under the plasma concentration - time curve (AUCss0-24) and the minimum inhibitory concentration (MIC) performed by GraphPad Prism v 5.0 software. The predictive index of drug effectiveness recommended was ASCss0-24/CIM>400. Statistics also was performed through by GraphPad Prism v 5.0 software by application of parametric tests to demographic data and also to laboratorial data (ANOVA, Student T test). Nonparametric statistics was applied related to dose, drug plasma measurements and AUC, kinetic data, data related to drug effectiveness (Mann Whitney). Statistical significant difference was considered, alpha lower than 0,05 (P<0,05). RESULTS -CONCLUSION: It was shown that the therapeutic target was reached to 85% (17/20) patients with the empiric daily dose of vancomycin (44-51) mg/kg, median (quartiles, IQ25-75) only for susceptible strains (MIC≤1mg/L). Then, changes of the prescription occurred in a real time and the daily dose was increased to 94 (85-104) mg/kg, p<0.05. New blood sampling was done at the steady state for TDM, PK and PK/PD approach and the target was reached for all patients MIC 1 mg/L strains; while the target was reached only 5/20 patients against MIC: 2mg/L susceptible strains, and none patient reached the target against MIC 4mg/L strains. It was shown that the drug effectiveness wasn\'t guaranteed by the vancomycin dose regimen recommended for the treatment of sepsis caused by nosocomial MIC≥1mg/L strains. In conclusion, TDM, pharmacokinetic study and PK/PD approach must be considered important tools do change vancomycin prescription in a real time in order to optimize the antimicrobial treatment of septic shock caused by nosocomial pathogens.
15

Simulação do co-tratamento de resíduo de tanque séptico em estação de tratamento de esgoto doméstico

Pistorello, Josiane January 2018 (has links)
O presente trabalho avaliou a possibilidade de receber e tratar resíduo de tanques sépticos num sistema dimensionado para tratar esgoto doméstico. Neste sentido, o objetivo deste estudo foi avaliar o co-tratamento deste resíduo numa estação de tratamento de esgoto composta por processo de lodos ativados. Para a realização desta avaliação utilizou-se o modelo matemático ASM1 e o software WRc Stoat 5.0. O modelo ASM1 descreve a remoção de matéria orgânica carbonácea, a nitrificação e a desnitrificação. Para atender ao objetivo proposto, foram realizadas simulações de quatro grupo de cenários, sendo que em cada grupo a ETE operava com uma vazão fixa e foi alterada a parcela de resíduo de tanque séptico a ser tratada no sistema. Para a realização das simulações, previamente realizou-se a estruturação do modelo matemático ao sistema de tratamento selecionado, ajustes dos coeficientes estequiométricos e parâmetros cinéticos e determinaram-se as concentrações de entrada e o fracionamento da DQO e do nitrogênio para o esgoto bruto e para o resíduo de tanque séptico. As simulações geraram como resultado a possibilidade de, num sistema dimensionado para uma vazão média de 180 m3/h e operado com uma vazão de 45 m3/h de esgoto doméstico receber 4,3 m3/h de resíduo de tanque séptico sem comprometer os padrões de lançamento. Já, no caso da mesma ETE operando com 90 m3/h, 135 m3/h e 162 m3/h, as parcelas possíveis de serem recebidas de resíduo de tanque séptico e concomitantemente atendendo aos padrões de lançamento definidos na legislação foram 3,6 m3/h, 3,3 m3/h e 2,9 m3/h. Os resultados obtidos permitem concluir que é viável co-tratar resíduo de tanque séptico com o esgoto doméstico e ao mesmo tempo atender aos padrões de lançamento definidos na legislação, desde que respeitados os fatores limitantes e as cargas máximas. O recebimento e o tratamento do resíduo de tanque séptico em sistemas projetados para esgoto doméstico mostram-se como práticas que podem ser implantados na gestão dos sistemas de esgotamento sanitário. Esta aplicação poderia contribuir para ampliar a correta destinação dos esgotos e consequentemente com a melhoria dos índices de atendimento do esgotamento sanitário. / The present work evaluated the possibility of receiving and treating septic tank residue in a system designed to treat domestic sewage. Therefore, the objective of this study was to evaluate the co-treatment of this residue in a sewage treatment plant with an activated sludge process. The ASM1 model and software WRc Stoat 5.0 were used to perform this evaluation. The ASM1 model describes the removal of carbonaceous organic matter, nitrification and denitrification processes. To attend the proposed objective, simulations of four scenarios group were realized and in each group the system operated with a fixed flow and was changed the portion of septic tank residue. Before running the simulations, the mathematical model was structured to the selected treatment system, adjustments of the stoichiometric coefficients and kinetic parameters and were determined the inputs and fractionations concentration of the COD and nitrogen for the sewage and the septic tank residue. The simulation results show that is possible, in a system designed for an average flow of 180 m3/h and underloaded with a domestic sewage flow of 45 m3/h to receive 4.3 m3/h of septic tank residue without compromising the standards. For systems operating at 90 m3/h, 135 m3/h and 162 m3/h, the possible parcels to be received from septic tank residue without compromising standards defined in the legislation were, respectively, 3.6 m3/h, 3.3 m3/h and 2.9 m3/h. The results allow the conclusion that it is feasible to co-treat septic tank residue with domestic sewage and at the same time respect the standards defined in the legislation, once the limiting flowrates and maximum loads are respected. The acceptance and treatment of septic tank residue in systems designed for domestic sewage are practices that can be implemented in the management of sanitary sewage systems. That can be enplaned to improve the management of sewage systems, therefore, expanding the correct destination of wastewater and consequently contribute to the improvement of sanitary sewage index.
16

Abordagem farmacocinética/farmacodinâmica (PK/PD) da vancomicina no controle da sepse por patógenos gram-positivos em pacientes queimados críticos pediátricos / Vancomycin pharmacokinetic-pharmacodynamic approach for the control of septic shock caused by gram-positive pathogens in paediatric critical burn patients

Vedilaine Aparecida Bueno da Silva Macedo 07 November 2017 (has links)
INTRODUÇÃO - OBJETIVO: A vancomicina é um glicopeptídeo de primeira escolha largamente prescrito aos pacientes críticos no tratamento de infecções graves causadas por patógenos nosocomiais Gram-positivos susceptíveis. Os pacientes grandes queimados são considerados pacientes críticos pelas condições metabólicas e importantes alterações fisiopatológicas decorrentes do choque séptico que modificam a farmacocinética da vancomicina. Destaca-se, entretanto que nos pacientes críticos queimados pediátricos essa alteração ocorre em diferente proporção quando comparada aquela reportada para pacientes adultos. Assim sendo, a efetividade desse antimicrobiano é um desafio para a equipe clínica da terapia intensiva, uma vez que a dose empírica nesses pacientes tem fornecido concentrações inferiores às recomendadas, resultando em falha terapêutica pela falta de cobertura do antimicrobiano contra patógenos susceptíveis, CIM ≥1mg/L. O objetivo foi realizar o monitoramento das concentrações plasmáticas de vancomicina seguido da abordagem farmacocinética-farmacodinâmica (PK/PD) a fim de se avaliar a efetividade do regime empírico recomendado ao paciente crítico pediátrico e se realizar o ajuste de dose para erradicação dos patógenos. CASUÍSTICA E MÉTODOS: Incluíram-se 20 pacientes (14M/6F), função renal normal com média de idade 5,95 (4,5-7,4) anos, peso 25,2 (20,5-30)kg, superfície de área queimada total 31,1(25-37)%. Os acidentes foram causados pelo fogo/ combustão por álcool; registrou-se lesão inalatória (12/20) e uso de drogas vasoativas e ventilação mecânica em 13/20 pacientes. Os exames de rotina laboratorial foram realizados diariamente; antes do início da terapia antimicrobiana, colheram-se amostras de sangue no D0 para cultura e realização do teste de susceptibilidade. Os pacientes foram investigados em diferentes seguimentos durante o choque séptico; o regime de dose empírica recomendada pelo CCIH foi prescrito e 3-4 amostras seriadas de sangue (1,5 mL/cada) foram coletadas do CVC no intervalo de dose após a dose diária empírica recomendada e após a individualização da terapia medicamentosa. A quantificação de vancomicina plasmática foi realizada através da cromatografia líquida. Na modelagem PK utilizou-se o programa PK Solutions Noncompartmental Data Analysis versão 2.0. Na abordagem PK/PD e no tratamento estatístico aplicou-se o programa GraphPad Prisma v.5.0. Empregou-se a razão da área sob a curva (ASCss0-24) e concentração inibitória mínima superior a 400 (ASCss0-24/CIM>400) como índice preditivo de efetividade recomendada para o antimicrobiano. Aplicou-se estatística paramétrica com relação aos dados demográficos e laboratoriais, e estatística não paramétrica com relação à dose, concentração plasmática, área sob a curva, constantes farmacocinéticas e efetividade do antimicrobiano. Aplicaram-se nesse estudo os testes paramétricos (ANOVA e Teste T de Student) e não paramétricos (Wilcoxon e Mann Whitney) no programa GraphPad Prisma v.5.0., e o nível de alfa igual ou inferior a 0,05 (P<0,05) foi considerado na significância estatística. RESULTADOS: A dose empírica de vancomicina foi 50 (44-51) mg/kg dia, mediana (quartis, IQ25-75) mostrou que o alvo foi atingido para 85% (17/20) dos pacientes apenas contra cepas sensíveis (CIM&≤1mg/L), ficando desta forma todos os pacientes desprotegidos contra cepas CIM >1mg/L (CIM: 2-4 mg/L). Então, registrou-se alteração de conduta médica relativa à prescrição com aumento da dose diária de vancomicina 94 (85-104) mg/Kg. Esse aumento se mostrou significativo com relação a dose inicial empírica, p<0,05. Após nova estabilização pela terapia dose ajustada, e coletas de sangue no platô, o alvo PK/PD foi alcançado para todos os pacientes, contra patógenos CIM 1mg/L. Entretanto, apenas 5/20 pacientes alcançaram o alvo PK/PD contra cepas susceptíveis CIM: 2mg/L, sendo que nenhum paciente se mostrou coberto contra cepas CIM 4mg/L. CONCLUSÃO: O regime empírico de dose recomendado para a vancomicina não se mostrou efetivo contra os patógenos sensíveis isolados. Concluindo, o controle terapêutico, estudo da farmacocinética e abordagem PK/PD realizado em tempo real possibilitou a alteração precoce de prescrição da vancomicina nos pacientes pediátricos grandes queimados de forma a otimizar a terapia antimicrobiana e o controle das infecções causadas por patógenos hospitalares susceptíveis (CIM ≥1mg/L). / INTRODUCTION- OBJECTIVE: Vancomycin is a first choice glycopeptide largely prescribed to critically ill adult or pediatric patients under therapy of severe infections caused by gram-positive susceptible nosocomial strains. Burn patients have metabolic conditions that change the pharmacokinetics of vancomycin in the treatment of severe infections. Pediatric patients are even more complicated because pharmacokinetic changes are quite different compared to adults, then effective vancomycin dose regimen is a challenge to clinic staff, once the initial dose recommended cannot reach the target against MIC ≥ 1 mg/L strains. Then therapeutic fail with impact on desired outcome. Therefore the rational of study was to apply therapeutic drug plasma monitoring (TDM) in order to identify the pharmacokinetic changes that occur in paediatric burns through PK/PD approach to perform in a real time the dose adjustment required. METHODS - CASUISTRY: Twenty septic burn pediatric patients was investigated after the admission in the Intensive Care Unit of Burns (ICBU) Plastic Surgery Division of HCFMUSP. Vancomycin empiric dose regimen recommended was prescribed 500mg every 6 hours, and patients received one hour drug infusion. Blood sampling was performed after drug infusion at time dose interval (1.5 mL/tube, sodium EDTA): 2nd or 3rd h, 4th, and before the next dose. Vancomycin was quantified by liquid chromatography (LC). Pharmacokinetics was investigated on the basis on one compartment open model by Noncompartmental Data Analysis PK Solutions v 2.0, software. PK/PD approach was based on the ratio of area under the plasma concentration - time curve (AUCss0-24) and the minimum inhibitory concentration (MIC) performed by GraphPad Prism v 5.0 software. The predictive index of drug effectiveness recommended was ASCss0-24/CIM>400. Statistics also was performed through by GraphPad Prism v 5.0 software by application of parametric tests to demographic data and also to laboratorial data (ANOVA, Student T test). Nonparametric statistics was applied related to dose, drug plasma measurements and AUC, kinetic data, data related to drug effectiveness (Mann Whitney). Statistical significant difference was considered, alpha lower than 0,05 (P<0,05). RESULTS -CONCLUSION: It was shown that the therapeutic target was reached to 85% (17/20) patients with the empiric daily dose of vancomycin (44-51) mg/kg, median (quartiles, IQ25-75) only for susceptible strains (MIC≤1mg/L). Then, changes of the prescription occurred in a real time and the daily dose was increased to 94 (85-104) mg/kg, p<0.05. New blood sampling was done at the steady state for TDM, PK and PK/PD approach and the target was reached for all patients MIC 1 mg/L strains; while the target was reached only 5/20 patients against MIC: 2mg/L susceptible strains, and none patient reached the target against MIC 4mg/L strains. It was shown that the drug effectiveness wasn\'t guaranteed by the vancomycin dose regimen recommended for the treatment of sepsis caused by nosocomial MIC≥1mg/L strains. In conclusion, TDM, pharmacokinetic study and PK/PD approach must be considered important tools do change vancomycin prescription in a real time in order to optimize the antimicrobial treatment of septic shock caused by nosocomial pathogens.
17

Avaliação de métodos para testes de suscetibilidade in vitro de enxaguantes bucais frente a espécies do gênero Candida / Evaluation of methods for in vitro susceptibility testing of mouthwashes against species of the gender Candida

Manuela Luiza Toti Rodrigues 08 December 2008 (has links)
A candidíase é uma infecção fúngica oportunista freqüente, causada por leveduras do gênero Candida. A utilização de anti-sépticos como medida complementar na higiene oral é cada vez mais difundida. Sendo assim, é de grande importância a avaliação das metodologias que são utilizadas para avaliação da atividade antifúngica. A avaliação in vitro da sensibilidade de leveduras a anti-sépticos tem sido pouco relatada e os resultados nem sempre são concordantes, pois as metodologias são divergentes. O objetivo desse estudo foi avaliar três metodologias: macro e microdiluição em caldo e difusão em ágar por meio de poços, com utilização dos meios de cultura RPMI 1640 e Mueller-Hinton para suscetibilidade dos anti-sépticos bucais Listerine®, Malvatricin® Dentes Sensíveis, Noplak®Max, Oral B®, Periogard®, Plax® e Reach® frente a C. albicans ATCC 64548, C. glabrata ATCC 90030, C. krusei ATCC 6258, C. parapsilosis ATCC 22019 e C. tropicalis ATCC 750. Em relação à comparação das concentrações inibitórias mínimas de cada meio de cultura, os índices kappa foram bons ou excelentes (0,73 a 1,00). Na metodologia da difusão em ágar o coeficiente de correlação de concordância entre os resultados dos meios de cultura também foi excelente (0,95 a 0,99). Concluímos que ambos os meios de cultura podem ser utilizados na avaliação da suscetibilidade de anti-sépticos bucais frente espécies de Candida, pois apresentaram índices de concordância e correlação de bom à excelente. Quanto à correlação entre as metodologias de macro e microdiluição, o kappa foi excelente (1,00) para todas as cepas no meio Mueller-Hinton e variou de 0,42 a 0,72 (bom a excelente) no meio RPMI-1640. As CIMs geradas pela macro e microdiluição em caldo são concordantes possibilitando a utilização de ambas as metodologias na avaliação de anti-sépticos bucais, no entanto a microdiluição detectou a ação inibitória de anti-sépticos voláteis em menores concentrações. A utilização da difusão em ágar é discutível visto que os anti-sépticos voláteis Listerine® e Malvatricin® não apresentaram atividade inibitória nesta metodologia. Todos os anti-sépticos avaliados apresentaram atividade fungistática e fungicida in vitro pelas metodologias de diluição frente a cepas ATCC de Candida quando avaliado na formulação disponibilizada pelos fabricantes. Os anti-sépticos bucais Oral B® e Periogard® apresentaram ações inibitórias (CIM) e fungicidas (CFM) de 1,25% para todas as cepas, meios e metodologias. O Noplak® e o Plax®, CIM e CFM variando de 1,25% a 2,5% para todas as cepas, meios e metodologias. Os anti-sépticos Listerine® e Malvatricin® apresentaram CIM de 5% a 50% e CFM de 5% a 100% dependendo do meio e metodologia. O anti-séptico Reach® apresentou CIM e CFM variando de 1,25% a 50% dependendo da cepa avaliada. Estudos com maior número de isolados, maior diversidade de espécies, concentrações intermediárias de anti-séptico e resultados interlaboratoriais poderão contribuir na padronização de métodos para avaliação de anti-sépticos bucais. / Candidosis is a frequent opportunistic fungal infection caused by yeasts of the gender Candida. The use of mouthwashes as a preventive measure in oral hygiene has been more and more diffused. Therefore it is of great importance the evaluation of the methodologies that are used on the antifungal evaluation. The in vitro evaluation of yeast susceptibility to mouthwashes has been little reported and the results are not always in agreement. The goal of this study was to evaluate three methodologies: broth macro and microdilution and agar well diffusion, using the media RPMI 1640 and Mueller-Hinton on the susceptibility of the mouthwashes Listerine®, Malvatricin® Dentes Sensíveis, Noplak®Max, Oral B®, Periogard®, Plax® e Reach® against C. albicans ATCC 64548, C. glabrata ATCC 90030, C. krusei ATCC 6258, C. parapsilosis ATCC 22019 e C. tropicalis ATCC 750. The kappa indexes for the comparison between the minimal inhibitory concentrations obtained with each culture medium were good to excellent (0,73 to 1,00). On the agar well diffusion method, the concordance correlation coefficients between the results obtained with the different media were also excellent (0,95 to 0,99). We concluded that both culture media can be used to evaluate the susceptibility of mouthwashes against species of Candida because they have concordance and correlations that go from good to excellent. The kappa indexes for the correlation between the broth macro and microdilution methodologies were excellent (1,00) for all the isolates in the Mueller-Hinton media and varied from 0,42 to 0,72 (good to excellent) with RPMI 1640. The MICs generated by broth macro and microdilution agree which makes it possible to use both methodologies on the evaluation of mouthwashes; however the microdilution detects the inhibitory action of volatile mouthwashes at smaller concentrations. The use of the agar well diffusion method is not advised since the volatile mouthwashes Listerine® and Malvatricin® have not presented inhibitory action in that methodology. All the evaluated mouthwashes presented fungistatic and fungicide activity at the formulation available in the market. The mouthwashes Oral B® and Periogard® presented MICs and MFCs of 1,25% for all strains, methodologies and media. Noplak® and Plax®, MIC and MFC that ranged from 1,25% to 2,5% for all strains, methodologies and media. The mouthwashes Listerine® and Malvatricin® MICs ranged from 5% to 50% and MFCs from 5% to 100% depending on media and methodology. The mouthwash Reach® presented MICs and MFCs ranging from 1,25% to 50% depending on the strain evaluated. Studies with a higher number of strains, bigger variety of species, intermediary concentrations of mouthwashes and interlaboratory results can contribute to the standardization of methods to evaluate mouthwashes.
18

Simulação do co-tratamento de resíduo de tanque séptico em estação de tratamento de esgoto doméstico

Pistorello, Josiane January 2018 (has links)
O presente trabalho avaliou a possibilidade de receber e tratar resíduo de tanques sépticos num sistema dimensionado para tratar esgoto doméstico. Neste sentido, o objetivo deste estudo foi avaliar o co-tratamento deste resíduo numa estação de tratamento de esgoto composta por processo de lodos ativados. Para a realização desta avaliação utilizou-se o modelo matemático ASM1 e o software WRc Stoat 5.0. O modelo ASM1 descreve a remoção de matéria orgânica carbonácea, a nitrificação e a desnitrificação. Para atender ao objetivo proposto, foram realizadas simulações de quatro grupo de cenários, sendo que em cada grupo a ETE operava com uma vazão fixa e foi alterada a parcela de resíduo de tanque séptico a ser tratada no sistema. Para a realização das simulações, previamente realizou-se a estruturação do modelo matemático ao sistema de tratamento selecionado, ajustes dos coeficientes estequiométricos e parâmetros cinéticos e determinaram-se as concentrações de entrada e o fracionamento da DQO e do nitrogênio para o esgoto bruto e para o resíduo de tanque séptico. As simulações geraram como resultado a possibilidade de, num sistema dimensionado para uma vazão média de 180 m3/h e operado com uma vazão de 45 m3/h de esgoto doméstico receber 4,3 m3/h de resíduo de tanque séptico sem comprometer os padrões de lançamento. Já, no caso da mesma ETE operando com 90 m3/h, 135 m3/h e 162 m3/h, as parcelas possíveis de serem recebidas de resíduo de tanque séptico e concomitantemente atendendo aos padrões de lançamento definidos na legislação foram 3,6 m3/h, 3,3 m3/h e 2,9 m3/h. Os resultados obtidos permitem concluir que é viável co-tratar resíduo de tanque séptico com o esgoto doméstico e ao mesmo tempo atender aos padrões de lançamento definidos na legislação, desde que respeitados os fatores limitantes e as cargas máximas. O recebimento e o tratamento do resíduo de tanque séptico em sistemas projetados para esgoto doméstico mostram-se como práticas que podem ser implantados na gestão dos sistemas de esgotamento sanitário. Esta aplicação poderia contribuir para ampliar a correta destinação dos esgotos e consequentemente com a melhoria dos índices de atendimento do esgotamento sanitário. / The present work evaluated the possibility of receiving and treating septic tank residue in a system designed to treat domestic sewage. Therefore, the objective of this study was to evaluate the co-treatment of this residue in a sewage treatment plant with an activated sludge process. The ASM1 model and software WRc Stoat 5.0 were used to perform this evaluation. The ASM1 model describes the removal of carbonaceous organic matter, nitrification and denitrification processes. To attend the proposed objective, simulations of four scenarios group were realized and in each group the system operated with a fixed flow and was changed the portion of septic tank residue. Before running the simulations, the mathematical model was structured to the selected treatment system, adjustments of the stoichiometric coefficients and kinetic parameters and were determined the inputs and fractionations concentration of the COD and nitrogen for the sewage and the septic tank residue. The simulation results show that is possible, in a system designed for an average flow of 180 m3/h and underloaded with a domestic sewage flow of 45 m3/h to receive 4.3 m3/h of septic tank residue without compromising the standards. For systems operating at 90 m3/h, 135 m3/h and 162 m3/h, the possible parcels to be received from septic tank residue without compromising standards defined in the legislation were, respectively, 3.6 m3/h, 3.3 m3/h and 2.9 m3/h. The results allow the conclusion that it is feasible to co-treat septic tank residue with domestic sewage and at the same time respect the standards defined in the legislation, once the limiting flowrates and maximum loads are respected. The acceptance and treatment of septic tank residue in systems designed for domestic sewage are practices that can be implemented in the management of sanitary sewage systems. That can be enplaned to improve the management of sewage systems, therefore, expanding the correct destination of wastewater and consequently contribute to the improvement of sanitary sewage index.
19

Simulação do co-tratamento de resíduo de tanque séptico em estação de tratamento de esgoto doméstico

Pistorello, Josiane January 2018 (has links)
O presente trabalho avaliou a possibilidade de receber e tratar resíduo de tanques sépticos num sistema dimensionado para tratar esgoto doméstico. Neste sentido, o objetivo deste estudo foi avaliar o co-tratamento deste resíduo numa estação de tratamento de esgoto composta por processo de lodos ativados. Para a realização desta avaliação utilizou-se o modelo matemático ASM1 e o software WRc Stoat 5.0. O modelo ASM1 descreve a remoção de matéria orgânica carbonácea, a nitrificação e a desnitrificação. Para atender ao objetivo proposto, foram realizadas simulações de quatro grupo de cenários, sendo que em cada grupo a ETE operava com uma vazão fixa e foi alterada a parcela de resíduo de tanque séptico a ser tratada no sistema. Para a realização das simulações, previamente realizou-se a estruturação do modelo matemático ao sistema de tratamento selecionado, ajustes dos coeficientes estequiométricos e parâmetros cinéticos e determinaram-se as concentrações de entrada e o fracionamento da DQO e do nitrogênio para o esgoto bruto e para o resíduo de tanque séptico. As simulações geraram como resultado a possibilidade de, num sistema dimensionado para uma vazão média de 180 m3/h e operado com uma vazão de 45 m3/h de esgoto doméstico receber 4,3 m3/h de resíduo de tanque séptico sem comprometer os padrões de lançamento. Já, no caso da mesma ETE operando com 90 m3/h, 135 m3/h e 162 m3/h, as parcelas possíveis de serem recebidas de resíduo de tanque séptico e concomitantemente atendendo aos padrões de lançamento definidos na legislação foram 3,6 m3/h, 3,3 m3/h e 2,9 m3/h. Os resultados obtidos permitem concluir que é viável co-tratar resíduo de tanque séptico com o esgoto doméstico e ao mesmo tempo atender aos padrões de lançamento definidos na legislação, desde que respeitados os fatores limitantes e as cargas máximas. O recebimento e o tratamento do resíduo de tanque séptico em sistemas projetados para esgoto doméstico mostram-se como práticas que podem ser implantados na gestão dos sistemas de esgotamento sanitário. Esta aplicação poderia contribuir para ampliar a correta destinação dos esgotos e consequentemente com a melhoria dos índices de atendimento do esgotamento sanitário. / The present work evaluated the possibility of receiving and treating septic tank residue in a system designed to treat domestic sewage. Therefore, the objective of this study was to evaluate the co-treatment of this residue in a sewage treatment plant with an activated sludge process. The ASM1 model and software WRc Stoat 5.0 were used to perform this evaluation. The ASM1 model describes the removal of carbonaceous organic matter, nitrification and denitrification processes. To attend the proposed objective, simulations of four scenarios group were realized and in each group the system operated with a fixed flow and was changed the portion of septic tank residue. Before running the simulations, the mathematical model was structured to the selected treatment system, adjustments of the stoichiometric coefficients and kinetic parameters and were determined the inputs and fractionations concentration of the COD and nitrogen for the sewage and the septic tank residue. The simulation results show that is possible, in a system designed for an average flow of 180 m3/h and underloaded with a domestic sewage flow of 45 m3/h to receive 4.3 m3/h of septic tank residue without compromising the standards. For systems operating at 90 m3/h, 135 m3/h and 162 m3/h, the possible parcels to be received from septic tank residue without compromising standards defined in the legislation were, respectively, 3.6 m3/h, 3.3 m3/h and 2.9 m3/h. The results allow the conclusion that it is feasible to co-treat septic tank residue with domestic sewage and at the same time respect the standards defined in the legislation, once the limiting flowrates and maximum loads are respected. The acceptance and treatment of septic tank residue in systems designed for domestic sewage are practices that can be implemented in the management of sanitary sewage systems. That can be enplaned to improve the management of sewage systems, therefore, expanding the correct destination of wastewater and consequently contribute to the improvement of sanitary sewage index.
20

Impacto do lançamento de lodo de tanques/fossas sépticas em estação de tratamento de esgoto com reator anaeróbio de fluxo ascendente e manta de lodo (UASB) / Impact of sludge disposal of septic tanks on wastewater treatment plant with upflow anaerobic sludge blanket (UASB)

Camila do Prado Gonçalves 31 October 2008 (has links)
Neste trabalho avaliou-se o desempenho de um reator anaeróbio de fluxo ascendente e manta de lodo (UASB) no tratamento combinado de esgoto sanitário com o lançamento de lodo proveniente de tanques sépticos. O estudo foi desenvolvido em escala plena na Estação de Tratamento de Esgoto (ETE) do Campus I da Universidade de São Paulo (USP) em São Carlos-SP. Foram utilizados dois reatores UASB com 18,8 m³ cada, um reator (UASB I) com função de controle e o outro reator (UASB II) no qual foi descarregado o lodo séptico. A pesquisa foi dividida em duas etapas: a primeira compreendeu o início de operação e o monitoramento dos reatores e, da segunda fez parte os ensaios de lançamento de lodo séptico no sistema. A partida foi efetuada sem utilização de inóculo e os reatores foram operados com tempo de detenção hidráulica médio (TDH) de 8 h, vazão afluente média de 2,35 m³/h e velocidade ascensional de 0,6 m/h. Em seis meses de operação os reatores apresentaram eficiências médias de remoção de DQO nos reatores UASB I e UASB II iguais a 49% e 65%. Quanto à remoção de sólidos os reatores UASB I e UASB II atingiram remoção de 36% e 37% para ST e de 67% e 63% para SST, respectivamente. Após esse período, deu-se início ao estudo que avaliou o impacto do lançamento de lodo séptico no UASB II. Foram realizados três ensaios com diferentes volumes de lodo (1; 3 e 5 m³) descarregados na forma de pulso com vazão média de 5,24 m³/h. Os lodos sépticos utilizados na pesquisa foram coletados por caminhões limpa-fossa e descarregados em um reservatório (15 m³) na ETE para posterior lançamento no reator UASB II. Foram feitas as caracterizações das amostras dos lodos sépticos (coletadas no ato da descarga em cada ensaio), com as quais pôde-se constatar a heterogeneidade da composição desse tipo de resíduo e sua viabilidade de pós-tratamento anaeróbio. Nos ensaios foram realizados monitoramentos temporais logo após a descarga de lodo para acompanhamento da resposta ao pulso de carga imposto. No geral, o reator UASB apresentou capacidade de degradar aproximadamente 2/3 da carga orgânica lançada com o lodo séptico. Os resultados são um indicativo de que a disposição de lodo sépticos em reatores UASB, quando bem programada, é uma solução viável e de grande importância para o tratamento dos resíduos provenientes de tanques/fossas sépticas. / The performance of upflow anaerobic sludge blanket (UASB) in the sanitary wastewater combined treatment with sludge disposal of septic tanks was evaluated in this work. The study was carried out (full scale) in the Wastewater Treatment Plant (WTP) located in campus I of the University of Sao Paulo (USP), city of Sao Carlos, State of Sao Paulo, Brazil. Two UASB reactors were used; volume of each reactor ~ 18,8 m³. UASB I was the control reactor, and UASB II was the reactor in which the septic sludge was disposed. The research was divided in two steps: the first one, which has taken into account the beginning of reactors operation and, the second one, in which occurred the disposal of septic sludge in the reactors. The start-up was carried out without utilization of inoculums. Reactors were operated with an average hydraulic retention time of 8 hours, average influent flow rate of 2.35 m³/h, and upflow velocity of 0.6 m/h. In six months, reactors presented average removal efficiencies of COD in UASB I and UASB II of 48% and 65%, respectively. Concerning to the solid removal, UASB I and UASB II have achieved removal of 36% and 37% for TS, and 67% and 63% for TSS, respectively. After this period of time, the evaluation of disposal impact of septic sludge was started in UASB II. Three essays with different sludge volume (1, 3, and 5 m³) were carried out; sludge volume was disposed in a pulse way with average flow rate of 5.24 m³/h. Septic sludge utilized in the research was collected by clean septic tank trucks, and disposed in a reservoir (volume of 15 m³) in WTP, in order to allow further disposal in the UASB II. By the hand of characterization of septic sludge samples (collected when disposal was carried out), it was possible to verify the heterogeneity about composition of this kind of waste and its availability in terms of anaerobic post-treatment. Temporal monitoring after the sludge disposal was carried out in order to allow the accompaniment of results provided by the pulse. In general, UASB reactor presented capacity in terms of degradation of approximately 2/3 of the organic load disposed with septic sludge. The results are a good indicative that the disposal of septic sludge in UASB reactors is a viable solution, and it is very important for the treatment of wastes from septic tanks.

Page generated in 0.0635 seconds