• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 207
  • 1
  • Tagged with
  • 210
  • 89
  • 78
  • 63
  • 60
  • 49
  • 48
  • 42
  • 36
  • 29
  • 29
  • 27
  • 26
  • 25
  • 24
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
71

Estudo do escoamento em condutores horizontais de sistemas de coleta de esgotos sanitários de edifícios residenciais. / Study of the flow in horizontal conductors of waste water systems of residential buildings.

Lúcia Helena de Oliveira 22 May 1991 (has links)
Os condutores horizontais dos sistemas de coleta de esgotos sanitários, no Brasil e em quase todos os países do mundo, tem sido dimensionados considerando-se o escoamento em regime permanente, o que na realidade não ocorre. Sabendo-se que o escoamento no interior destes condutores acontece em regime não permanente, caracterizado pelo movimento de ondas, devido a aleatoriedade de uso dos aparelhos. Neste trabalho, apresentamos o estudo do escoamento não permanente, verificado, nos ramais e coletores dos sistemas de coleta de esgotos sanitários de edifícios residenciais. As equações diferenciais da continuidade e da quantidade de movimento, que regem este escoamento, são resolvidas pelo método das características. Apresentamos, também, os resultados e análise de várias simulações do programa de computador desenvolvido com base no método das características pelo professor Swaffield, da Universidade Heriot-Watt, Escócia. Os dados de entrada para estas simulações foram obtidos a partir de ensaios laboratoriais de algumas configurações de ambientes sanitários brasileiros, também apresentados neste trabalho. Os resultados destas simulações mostram que a consideração do escoamento em regime não permanente, possibilita a redução dos diâmetros dos ramais e coletores, e consequentemente, a redução dos custos destes sistemas. / Usually horizontal waste pipes of Building Drainage Systems, in Brazil and almost all of countries in the world, are dimensioned considering a steady flow, that does not exist. The random use of the sanitary appliances connected to the Drainage Systems of the building is the responsible for the unsteady flow. We present a study of unsteady partially filled pipeflow for drains and sewers. The differential equations of continuity and motion are solved via the method of characteristics. We present, also, the results and analysis of several simulations using a computational program developed by Prof. Swaffield-Heriot - Watt University, Scotland. The data entry were obtained through laboratorial tests which considered brazilian bathroom configurations, presented in this work. The results show us that the consideration of unsteady flow conduct to the reductions of horizontal waste pipes diameters, consequently to the reduction of the Building Drainage Systems costs.
72

Redução dos diâmetros de ramais e coletores nos sistemas prediais de esgotos sanitários. / Diameter reduction on drains and main drains of building dranaige system.

Bruno Tavares Baroni 04 June 2018 (has links)
O aumento da demanda por água potável em função do crescimento populacional, vem sendo objeto de estudo de diversos pesquisadores que buscam meios de otimizar o uso desse recurso. Desse modo, ao longo dos anos os equipamentos sanitários foram sendo aperfeiçoados para tornarem-se mais eficientes. Uma preocupação é o impacto nos ramais e coletores de sistemas prediais de esgotos sanitários, uma vez que os componentes economizadores ao demandarem menos água em sua operação, retornam vazões menores para a rede predial de esgoto sanitário e, consequentemente, geram ondas menores que impactam negativamente na autolimpeza dos condutos horizontais. Nesse sentido, o objetivo da pesquisa foi investigar, em laboratório, as vazões e profundidades da lâmina d´água do escoamento em ramais e coletores do sistema de esgotos sanitários de edifícios residenciais unifamiliares, tendo em vista a redução de diâmetros de 100 mm para 75 mm. A pesquisa foi realizada em laboratório vertical, onde foi montada uma configuração típica de um banheiro residencial, localizada no pavimento superior. Foram utilizadas bacias sanitárias com volume nominal de descarga de 6 L e 4,8 L, um chuveiro com vazão constante de 0,20 L/s e um lavatório com vazão constante de 0,15 L/s. As bacias sanitárias foram ensaiadas para calibração, segundo a NBR 15097 (ABNT, 2011) e ambas obtiveram resultados satisfatórios em todos os requisitos dessa norma. Foram variados os diâmetros dos ramais e coletores prediais de 100 mm para 75 mm, com e sem a contribuição da vazão em regime permanente de 0,35 L/s proveniente de um chuveiro e um lavatório e as declividades variadas em 0%, 1% e 2% nos ramais e 1%, 2% e 3% nos coletores de esgoto. Avaliou-se a influência dos parâmetros declividade, volume de descarga, presença ou não de vazão em regime permanente e diâmetro da tubulação, sobre a velocidade de escoamento da água. Concluiu-se que a redução dos diâmetros dos ramais e coletores de esgoto e a redução do volume de descarga de 6 L para 4,8 L contribuíram para o aumento da velocidade da onda sob as condições de estudo em todo o trecho ensaiado, ou seja, no trecho compreendido entre a bacia sanitária e o tubo de queda e ao longo de todo comprimento de 3 m do coletor de esgoto predial. Não foi estudada a influência da variação dos parâmetros sobre a velocidade de onda em trechos além do coletor de esgoto predial. Sob as condições de estudo, observou-se que a declividade não influencia, de maneira geral, no desempenho do sistema nos trechos ensaiados. A presença de uma vazão em regime permanente contribui para amortizar a energia da onda de descarga da bacia sanitária no ramal de descarga e consequentemente, reduz a velocidade de escoamento da água, o que pode contribuir para a piora do requisito de autolimpeza neste trecho da tubulação. No coletor de esgoto, não foi possível concluir que a presença de vazão em regime permanente tem impacto sobre a velocidade de escoamento da água. Por fim, conclui-se ser possível a redução dos diâmetros dos ramais e coletores do sistema predial de esgoto sanitário. / The increase in the demand for drinking water due to the population growth has been the object of study of several researchers who seek ways to optimize the use of this resource. In this way, over the years sanitary equipment has been improved to become more efficient. One concern is the impact on drains and main drains of building drainage system, since the economizing components, while using less water in their operation, return smaller flows to the sanitary sewage network and consequently lead to the formation of smaller waves that contribute to the self-cleaning of pipes. In this sense, the objective of the research was to investigate, in the laboratory, the flows and the depths of the flow in drains and main drains of residential building drainage system, in order to reduce diameters from 100 mm to 75 mm. The research was carried out in a vertical laboratory, where a typical configuration of a residential bathroom located on the second floor of a two story building was set up. A toilet with a nominal discharge volume of 6 L and 4,8L, a shower with a constant flow rate of 0.20 L/s and a lavatory with a constant flow rate of 0.15 L/s were used. The toilets were tested according to NBR15097 (ABNT, 2011) for calibration and both obtained satisfactory results in all the requirements of this standard. The diameters of the drains and main drains were varied from 100 mm to 75 mm with and without the contribution of the continuous flow rate of 0.35 L/s from a shower and lavatory and the slopes varying in 0%, 1% and 2% in the drains and 1%, 2% and 3% in the main drain. The influence of the parameters like slope, discharge volume, presence or not of continuous flow rate and pipe diameter, on the water flow velocity were evaluated. It was concluded that the reduction of the diameters of the drains and main drains and the reduction of the volume of discharge from 6 L to 4.8 L contribute to the increase of the velocity of the wave in the whole parts of the drain and main drain. It was not studied the influence of the variation of the parameters on the wave velocity on parts beyond the main drain. It was observed that the slope variation does not influence in general performance of the system. The presence of a continuous flow rate contributes to amortize the discharge wave energy from the toilet at the drains and consequently reduces the flow velocity of the water, which may contribute on deterioration of the self-cleaning requirements in this section of the pipeline. In the main drain, it was not possible to conclude that the presence of permanent flow has an impact on the flow velocity of the water.
73

Critérios de avaliação de sustentabilidade ambiental dos sistemas prediais hidráulicos e sanitários em edifícios de escritórios. / Assessment criteria for environmental sustainability on office buildings hydraulic and sanitary systems.

Andreza Kalbusch 06 July 2006 (has links)
A definição de desenvolvimento sustentável da World Commission on Environment and Devolopment aponta para um desenvolvimento econômico e social capaz de atender às necessidades desta geração, não comprometendo o atendimento das necessidades das gerações futuras. A gestão do uso da água, enquanto estratégia para preservação deste recurso, vem ao encontro do conceito de desenvolvimento sustentável, uma vez que pretende garantir que haja água disponível para as gerações futuras e que, sem este recurso, não há possibilidade de vida no planeta. Em relação a edifícios, a conservação da água pode ser alcançada através do emprego de práticas e de tecnologias que levem a uma utilização mais sustentável deste recurso, sem que haja interferência no conforto dos usuários. O presente trabalho pretende ser uma contribuição e um incentivo às práticas de conservação da água no ambiente construído, além de ser uma contribuição para a aplicação dos conceitos de sustentabilidade ambiental no projeto e execução de sistemas prediais hidráulicos e sanitários na construção civil brasileira. Para isso, detalha-se a maneira como alguns sistemas de avaliação de sustentabilidade ambiental de edifícios de escritórios avaliam itens relacionados aos sistemas prediais hidráulicos e sanitários e ao uso da água. O objetivo é aprofundar os critérios de avaliação de sustentabilidade ambiental dos sistemas prediais hidráulicos e do uso da água propostos para edifícios de escritório com base na documentação técnica e normalização brasileira consultadas. / The World Commission on Environment and Development definition for sustainable development points towards a social and economic development capable of taking care of the necessities of this generation without compromising the necessities of future generations. Water management creates strategies that secure the preservation of this resource and also fits the concept of sustainable development, since it intends to ensure the availability of water for generations to come and understands that without this resource there is no possibility of life on Earth. When it comes to buildings, water preservation is possible through the application of practices and technologies that will lead to a more sustainable use of this resource, without interfering on the daily activities of users and their needs and comfort. The purpose of this study is promoting actions regarding water preservation in buildings and contributing to the application of environmental sustainability concepts in hydraulic and sanitary systems on the Brazilian construction industry. For that reason it contains the details and the evaluation criteria on how some of the environmental assessment methods actually evaluate items that are related to hydraulic and sanitary systems and water usage. Therefore its main objective is to study the evaluation criteria for environmental sustainability on hydraulic and sanitary systems and water use for office buildings based on the consulted technical documentation and relevant Brazilian standards.
74

Avaliação de um sistema australiano de lagoas no tratamento conjunto de esgoto sanitário e líquidos percolados gerados em aterro sanitário / Evaluation of a system of stabilization lagoons for the joint treatment of wastewater and leachates

Marcus Cesar Avezum Alves de Castro 06 July 2001 (has links)
Um dos desafios na elaboração de projetos de aterros sanitários é o equacionamento do destino/tratamento dos líquidos percolados em função das elevadas concentrações de poluentes, associadas a grandes variações, e seu abrandamento natural ao longo do tempo. Nesse sentido, o trabalho avalia, a partir da montagem de unidade piloto, a viabilidade do lançamento dos líquidos percolados gerados no aterro de sanitário, localizado no município de Piracicaba-SP, na Estação de Tratamento de Esgoto que dispõe de sistema australiano de lagoas. A unidade foi montada na própria estação e operada durante 18 meses, sendo avaliado o comportamento da eficiência para vazões crescentes de líquidos percolados. No trabalho foi investigado também a adequação dos métodos Suíço, Racional e do Balanço Hídrico na previsão da taxa de geração de líquidos percolados, a partir da comparação das estimativas obtidas pela aplicação dos métodos com a observada na prática. De maneira geral, pode-se dizer que é viável o lançamento de chorume em estações de tratamento de esgoto, sem prejuízo na eficiência do sistema. Com relação às estimativas das vazões de chorume pela aplicação dos métodos, os erros variaram desde menos 22% até mais 20% da vazão obtida na prática. / One of the challenges in the project of sanitary landfills is the solution of the destination/treatment of leachates due to the high concentration of pollutants, which is also associated to large variations and a natural reduction with time. This work evaluates, based on a pilot unit, the feasibility of the treatment of leachates, produced in sanitary landfills, in a wastewater treatment plant that uses a system of stabilization lagoons. The pilot unit was mounted in the wastewater treatment site and operated for 18 months, in which the performance was monitored for crescent flowrates of leachates. It was also investigated the prediction of leachate flowrates by different methods (Swiss, Rational and Hydric Balance) based on the comparison of predicted leachate generation rates with observed data. In general, it is possible to perform the treatment of leachates in wastewater treatment plants because there was no reduction of efficiency. Related to the prediction of leachate volumes, the errors of the tested methods range from -22% to + 20% of the observed flowrates.
75

Estudo dos lixiviados das frações do aterro sanitário de São Carlos - SP por meio da caracterização físico-química / Study from de leachate of fractions from São Carlos landfill - SP through the physicochemical characterization

Adriana Gonçalves Ferreira 14 May 2010 (has links)
Este trabalho teve como objetivo determinar as fases de decomposição das frações dos resíduos dispostos no aterro sanitário de São Carlos - SP a partir do estudo das características dos lixiviados gerados. Foram coletadas amostras do lixiviado gerado na parte mais antiga do aterro (encerrada a 10 anos) e nas 1ª, 2ª e 3ª ampliações (esta última em operação). A coleta foi dividida em dois períodos: seco (junho a setembro de 2009) e chuvoso (outubro a dezembro de 2009). As seguintes análises foram realizadas: pH, alcalinidade, ácidos voláteis totais, DQO, sólidos, metais, NTK e \'N\' amoniacal. Em todos pontos os valores de pH encontrados foram superiores a 8. A alcalinidade variou entre 4000 e 12000 mg/L \'CA\'\'CO IND.3\' enquanto os AVT apresentaram concentrações sempre inferiores a 700 mg/L \'CA\'\'CO IND.3\'. A DQO apresentou concentrações entre 3000 e 7000 mg/L durante o período seco, decaindo para 2000 e 4000 mg/L no período chuvoso. Os resultados encontrados sugerem que o lixiviado de todos os pontos encontram-se na fase metanogênica de decomposição da matéria orgânica. A partir dos resultados de NTK e \'N\' amoniacal ficou evidente que a amônia é o poluente presente em maior concentração no lixiviado - corresponde a mais de 70% do NTK. A biodegradabilidade foi investigada através das relações AVT/DQO e STV/ST e resultaram em valores menores que 0,25 e 0,3 respectivamente, indicando que o lixiviado do aterro de São Carlos possui baixa biodegradabilidade. / This work aimed to determine the stages of the decomposition of the waste disposed in São Carlos - SP landfill fractions through the study of the characteristics of the generated leachate. Samples were collected from the older area of the landfill (closed 10 years ago), and also from the first, second and third new built areas (garbage is still being dumped in the third one). The samples were collected in two periods: the dry one (from June to September 2009) and the rainy one (from October to December 2009). The concentration of pH, alkalinity, total volatile acids, COD, solids, metals, sodium and potassium, total nitrogen and ammonium-\'N\' were determined in the study. In all the points sampled the values of pH were higher than 8. The alkalinity ranged from 4000 mg/L to 12000 mg/L \'CA\'\'CO IND.3\', while the total volatile acids concentrations were less than 700 mg/L \'CA\'\'CO IND.3\'. The COD present concentrations between 3000 e 7000 mg/L in the dry period decaying to 2000 and 4000 mg/L in the rainy period. The results found suggest that all the leachate analyzed is in the methanogenic phase of the organic matter. From the total nitrogen and ammonium \'N\' results it turned out to be evident that ammonia is the major pollutant present in the leachate - more than 70% of the total nitrogen. The biodegradability was investigated through the relations VFA/COD and VS/TS and resulted in values lower than 0,25 and 0,3 respectively, indicating that the leachate from São Carlos landfill has low biodegradability.
76

Protótipo de biofiltro percolador com uso de meio suporte sintético / Prototype of biofilter percolator with synthetic support

Bergamini, Natália Cedran, 1984- 26 August 2018 (has links)
Orientador: Carlos Gomes da Nave Mendes / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Civil, Arquitetura e Urbanismo / Made available in DSpace on 2018-08-26T02:02:33Z (GMT). No. of bitstreams: 1 Bergamini_NataliaCedran_M.pdf: 5745897 bytes, checksum: 69560c23a66d8d968b36f4b34e17bc8d (MD5) Previous issue date: 2014 / Resumo: Este trabalho consistiu em inovação tecnológica antes nunca testada desde a concepção, projeto, construção e operação de um biofiltro percolador de tratamento de esgoto sanitário em escala piloto. O reator foi desenvolvido nas instalações do Laboratório de Protótipos da Faculdade de Engenharia Civil da UNICAMP, cidade de Campinas, estado de São Paulo, é constituído de pré-filtro fabricado com a manta acrílica resinada, 3 reatores biológicos percoladores dispostos em séries, revestidos de não tecido sintético e filtro secundário confeccionado do mesmo material do pré-filtro. A vazão real média de alimentação do sistema era de 12,8 L h-1, tendo sido operado em regime hidráulico com tempo de detenção hidráulico variável de 82 a 100 minutos. A inovação baseou-se no uso de não tecido sintético com tripla função: a) proporcionar o fluxo do substrato sob ação da gravidade; b) promover a troca gasosa entre o meio líquido e a atmosfera; e c) constituir-se como meio suporte da biomassa, além de verificar as condições operacionais e tipos de mantas para viabilizar o tratamento de esgoto na remoção de matéria carbonácea sem a necessidade de aeração artificial. Neste estudo, foi analisada a remoção de sólidos suspensos (SS), turbidez, oxigênio dissolvido, DQO e DBO5. Os resultados médios de remoção de DQO e de DBO nas diferentes fases operacionais variaram de 75 a 86% e de 80 a 86%, respectivamente. As concentrações médias de DQO no efluente final variaram de 81 a 179 mg/L, enquanto as concentrações médias de DBO estiveram entre 47 a 97 mg/L. As médias globais de SST no efluente final foram mantidas em 49 mg/L. Com remoção de turbidez de 92,8%. O sistema PF/FBP (Pré-filtro/Filtro Biológico Percolador) pode se tornar uma alternativa muito promissora para o tratamento de esgoto sanitário de pequenas instalações do Brasil, uma vez que o sistema manifestou baixos tempo de detenção hidráulica e eficiência na remoção de DQO, DBO5 e sólidos suspensos, resultando em uma instalação compacta e de baixos custos. Além disso, o consumo de energia e os custos operacionais são mínimos / Abstract: This work consisted in technological innovation never before tested from conception, design, construction and operation of a trickling biofilter wastewater treatment in pilot scale. The reactor was developed on the premises of the Laboratory Prototypes of the Faculty of Civil Engineering, UNICAMP, Campinas, São Paulo, is constituted of prefilter manufactured with resin-coated acrylic blanket, three biological trickling reactors arranged in series, coated and synthetic nonwoven secondary filter made of the same material pre-filter. The average real power flow of the system was 12,8 L h-1, having been operated hydraulic system with variable hydraulic detention time of 82-100 minutes. The innovation is based on the use of non-synthetic fabric with three functions: a) providing the flow of the substrate under the action of gravity; b) promote gas exchange between the liquid medium and the atmosphere; c) to establish itself as a means of support biomass and to check the operating conditions and types of blankets to enable wastewater treatment for the removal of carbonaceous matter without the need for artificial aeration. In this study, we analyzed the removal of suspended solids (SS), turbidity, dissolved oxygen, COD and BOD5. The average results of COD removal and BOD in the different operational phases ranged 75-86% and 80 to 86%, respectively. The average concentrations of COD in the final effluent ranged 81-179 mg/L, while the average concentrations of BOD were between 47-97 mg/L. Global average of TSS in the final effluent were maintained on 49 mg/L. To remove turbidity of 92.8%. The PF / BTF (Pre-filter / Biological trickling filter) system can become a very promising alternative for treating sewage from small installations from Brazil, once the system showed low hydraulic retention time and removal efficiency of COD , BOD5 and suspended solids, resulting in a compact installation and low costs. Furthermore, the energy consumption and operating costs are minimal / Mestrado / Saneamento e Ambiente / Mestra em Engenharia Civil
77

Avaliação da toxicidade de efluente sanitário tratado e condicionado para aplicação na agricultura, utilizando Allium cepa, Daphnia similis e Vibrio fischeri, como organismos-teste / Toxicity assessment of treated sanitary effluent for application in agriculture, using Allium cepa, Vibrio fischeri and Daphnia similis as test organisms

Torres, Danila de Leone França e Freitas 21 August 2018 (has links)
Orientador: Alexandre Nunes Ponezi / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Civil, Arquitetura e Urbanismo / Made available in DSpace on 2018-08-21T07:25:38Z (GMT). No. of bitstreams: 1 Torres_DaniladeLeoneFrancaeFreitas_M.pdf: 2036503 bytes, checksum: 068ab775d9c675592e34d0bfdd2ca1e9 (MD5) Previous issue date: 2012 / Resumo: O uso de efluente tratado na agricultura irrigada constitui uma alternativa adequada para a preservação de mananciais, além de ser uma importante fonte de nutrientes. No entanto, os riscos de toxicidade devem ser avaliados. Testes ecotoxicológicos apresentam-se como uma ferramenta apropriada, devido à sensibilidade dos organismos e sua ampla aceitação por órgãos governamentais e científicos. O objetivo do presente estudo foi avaliar a toxicidade aguda na fotobactéria marinha Vibrio fischeri e no microcrustáceo Daphnia similis (CE50) e do potencial citotóxico, genotóxico e mutagênico em Allium cepa (cebola) de um efluente sanitário tratado usado para irrigação. Os ensaios foram realizados no efluente bruto e nos tratados utilizados para irrigação: anaeróbio e pos-tratamento anaeróbio (nitrificado). Os resultados evidenciaram que o efluente bruto, apresentou uma maior variação dos valores de CE50 para ambos os organismos. O efluente anaeróbio apresentou um efeito tóxico agudo maior para V. fischeri que para D. similis. Já o nitrificado (pos-tratamento anaeróbio) apresentou uma toxicidade aguda menor para ambos os organismos testados. Na avaliação das aberrações cromossômicas em A. cepa, os efluentes tratados apresentaram uma redução do potencial citotóxico (p<0,05) em relação ao efluente bruto. Pode-se concluir que os testes escolhidos foram adequados para o monitoramento do efluente. Recomenda-se que o uso de efluente tratado na agricultura seja realizado de forma regrada, atentando para os padrões de Boas Práticas Agrícolas (GAP) e de toxicidade. Além disso, em escala real é necessário um estudo de monitoramento periódico que avalie impactos a longo prazo, incluindo testes de toxicidade crônica / Abstract: The use of the treated effluent in agriculture has proven to be an important alternative, since its preservation of water and its potential as source of nutrients, with low potential for negative impact on the environment. However, toxicity remains an important issue. Ecotoxicological tests are appropriate tools to evaluate the toxicity of effluents. The aim of this study was to evaluate acute toxicity on marine bacteria Vibrio fischeri, on micro crustacean Daphnia similis (EC50) and on Allium cepa (onion) (assessment of cytotoxic, mutagenic and genotoxic potencial) in treated sanitary effluent used for irrigation. We tested the raw effluent, and in its treatments, used for irrigation: anaerobic and anaerobic posttreatment (nitrified). Our results showed that the raw effluent had a greater variation of EC50 for both organisms, due to an intrinsic variability of its composition. The anaerobic effluent had a greater acute toxic effect on V. fischeri than for D. similis. Yet, the nitrified (anaerobic post-treatment stage) showed a lower toxicity for both tested organisms. We found a reduction in the citotoxical potential in A. cepa as compared to the raw efluente. We concluded that the tests chosen were adequate for monitoring the effluent since the organisms showed adequate sensitivity. It is therefore suggested that the use of treated wastewater in agriculture should be standardized, noting Good Agricultural Practices (GAP) and toxicity stardards. Furthermore for larger scale assumption it is necessary a periodic monitoring study to assess long term impacts, including chronic toxicity tests / Mestrado / Saneamento e Ambiente / Mestra em Engenharia Civil
78

Análise dos critérios do meio físico aplicados na definição de áreas para aterros sanitários nos processos de licenciamento ambiental : realidade e perspectivas /

Aguiar, Maisa Comar Pinhotti January 2019 (has links)
Orientador: Marcus Cesar Avezum Alves de Castro / Resumo: O presente estudo teve como objetivo principal analisar a incorporação dos critérios do meio físico na seleção de áreas para implantação de aterros sanitários nos processos de licenciamento ambiental no Estado de São Paulo. A investigação foi realizada a partir da análise de estudos ambientais de aterros sanitários (EIA/RIMA e RAP) apresentados para a Companhia Ambiental do Estado de São Paulo (CETESB), em atendimento ao processo de licenciamento ambiental no Estado de São Paulo. A avaliação da incorporação dos critérios na seleção das áreas nos processos de licenciamento baseou-se em aterros sanitários localizados nas áreas de alta, média e baixa vulnerabilidade à contaminação de águas subterrâneas, conforme Mapa de Vulnerabilidade à Contaminação de Águas Subterrâneas do Estado de São Paulo (IG/DAEE/CETESB, 1997). Foram selecionados um (01) aterro na área de alta vulnerabilidade, dois (02) na de média vulnerabilidade e três (03) na área de baixa vulnerabilidade. A análise dos critérios do meio físico dos EIA-RIMA foi pautada nos capítulos de “Alternativas Locacionais” e “Diagnóstico do Meio Físico”. Com base nos resultados da avaliação dos relatórios ambientais verificou-se que, usualmente, o meio físico não foi considerado determinante na seleção da área de implantação do aterro, predominando critérios financeiros na escolha locacional dentre as alternativas apontadas para cada área. Quanto à caracterização do meio físico apresentada nos relatórios, ela atendeu, em linhas g... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The main objective of this study was to analyze the incorporation of the criteria of the The main objective of this study was to analyze the incorporation of the criteria of the physical environment in the selection of areas for the implementation of sanitary landfills in environmental licensing processes in the State of São Paulo. The investigation was carried out based on the analysis of environmental studies of sanitary landfills (EIA/RIMA and RAP) presented to the Environmental Company of the State of São Paulo (CETESB), in compliance with the environmental licensing process in the State of São Paulo. The evaluation of the incorporation of the criteria in the selection of the areas in the licensing processes was based on sanitary landfills located in areas of high, medium and low vulnerability to groundwater contamination, according to the Map of Vulnerability to Groundwater Contamination of the State of São Paulo (IG/DAEE/CETESB, 1997). One (01) landfill was selected in the area of high vulnerability, two (02) in the area of medium vulnerability and three (03) in the area of low vulnerability. The analysis of the criteria of the physical environment of the EIA-RIMA was based on the chapters "Local Alternatives" and "Diagnosis of the Physical Environment". Based on the results of the evaluation of the environmental reports, it was verified that, usually, the physical environment was not considered determinant in the selection of the area of implementation of the landfill,... (Complete abstract click electronic access below) / Doutor
79

Pós-tratamento de efluente de lagoa facultativa fotossintética em filtros biológicos percoladores visando remoção de nitrogênio amoniacal. / Post-treatment of photosynthetic facultative pond effluent on trickling filters in order to remove ammonia.

Medeiros, Mônica 01 April 2011 (has links)
Neste trabalho, estudou-se a utilização de filtros percoladores como tratamento complementar de efluente de lagoa de estabilização visando a remoção de nitrogênio, principal causador de problemas como a eutrofização de corpos hídricos em conjunto com o fósforo. A motivação principal para o desenvolvimento desta pesquisa foi a dificuldade encontrada para o atendimento ao padrão definido pela Resolução CONAMA 357/05, a qual define concentração máxima de nitrogênio para lançamento de efluentes em corpos hídricos receptores de 20 mg/l. Em 2008 foi promulgada a Resolução CONAMA nº 397 a qual estabeleceu, em seu Artigo 34, que o padrão de emissão de nitrogênio amoniacal seria suspenso temporariamente para efluentes de estação de tratamento de esgoto sanitário, continuando a valer a concentração máxima nos corpos receptores estabelecidas na Resolução CONAMA 357/05. Sendo assim, a questão sobre a remoção de nutrientes constitui uma preocupação diretamente relacionada ao emprego dos sistemas de lagoas de estabilização. Para esta pesquisa, utilizou-se os efluentes tratados por lagoas facultativas provenientes da Estação de Tratamento de Esgoto do município de Lins/SP e, para o experimento em questão, foram construídos dois filtros biológicos seguidos de decantadores, ambos em escala piloto. Os filtros foram construídos em um corpo cilíndrico de polipropileno com diâmetro de 1,2 metros e teve seu volume dividido igualmente por uma placa vertical também de polipropileno, propiciando área superficial de 1,13 m² e volume útil total de 4,52m³. Para o fornecimento de oxigênio, indispensável para o processo de nitrificação, o filtro foi apoiado sobre uma base de concreto com drenos de fundo para permitir a ventilação do sistema, garantindo a concentração de oxigênio necessária. Para comparação da eficiência na remoção do nitrogênio, cada filtro foi preenchido com determinado tipo de material, ou seja, um filtro continha pedra britada variando de 4 a 8, admitindo-se área superficial de 70 m²/m³ e possibilitando uma área para formação de biofilme de 316,7 m², enquanto que no outro filtro foram utilizado anéis plásticos com área superficial de 100m³/m³, fornecendo 542,9 m² de área superficial para a formação de biofilme. Também foram construídos decantadores após os filtros percoladores para a remoção dos sólidos em suspensão, não sendo alvo da pesquisa em questão Tendo em vista que o molhamento de todo o material de preenchimento se faz importante para a eficiência do sistema, foi utilizado um sistema de recalque para o transporte do esgoto para o filtro, distribuído continuamente sobre o meio suporte e com vazão divida igualmente para os dois filtros por meio de um sistema de distribuição de pvc perfurado com diâmetro de 40 mm e com funcionamento semelhante a um aspersor de jardim A taxa de aplicação superficial variou entre baixa, intermediária e alta, tendo aumento de vazão no sistema até que o processo de nitrificação cessasse e cada fase teve duração de 180 dias. Conforme verificado nos resultados obtidos, filtros percoladores apresentam boa eficiência na remoção do nitrogênio do efluente, seja pela desnitrificação via nitrito ou pela volatilização do nitrogênio. A ETAPA 1 apresentou resultados bastante satisfatórios para o filtro de brita em relação ao filtro com anéis plásticos, podendo ter sido ocasionado pela área rugosa das britas, a qual facilitou a formação do biofilme, enquanto que a superfície lisa dos anéis plásticos dificulta a formação do biofilme, resultando na baixa eficiência apesar da maior área superficial. Já na ETAPA 3, com taxas de aplicação maiores, o filtro preenchido com anéis plásticos apresentou maior eficiência do que o filtro com brita. Tal fato pode ter sido conseqüência da maior área disponível para a formação do biofilme nos anéis plásticos. Ambos os casos apresentaram eficiência suficiente para remoção de nitrogênio a concentrações inferiores a 20 mg/l. Tais resultados demonstram que os filtros percoladores possuem boa funcionalidade para a remoção do nitrogênio de efluente sanitário tratado por sistemas de lagoas de estabilização. / It was studied in this paper the use of trickling filters as a complementary treatment of wastewater stabilization pond seeking removal of nitrogen, the main cause of problems such as eutrophication of water bodies in conjunction with phosphorus. The main motivation for this research was the difficulty to meet the standard set by CONAMA 357/05 Resolution, which defines the maximum nitrogen concentration for disposal of effluents in water bodies as 20 mg / l. In 2008 was created the CONAMA Resolution 397 which established, in Article 34 that the emission pattern of ammonia nitrogen would be temporarily suspended for wastewater treatment plant discharge, continuing to enforce the maximum concentration in the water bodies established in CONAMA Resolution 357/05. Thus, the question on the removal of nutrients is a concern related to the use of systems of waste stabilization ponds. For this study, was used the treated effluent by anaerobic and facultative ponds from the Sewage Treatment Plant in the city of Lins/SP, and for this experiment was constructed two trickling filters followed by settlers, both in pilot scale. The filters were constructed on a cylindrical body of polypropylene with a diameter of 1.2 meters and its volume was divided symmetrically by a vertical plate also made of polypropylene, providing superficial area of 1.13m² and total net volume of 4.52m³. To supply oxygen, essential for the nitrification process, the filter was supported on a concrete base with bottom drains to allow the ventilation system, to supply the concentration of oxygen needed. To compare the efficiency of nitrogen removal, each filter was filled with a certain type of material, ie, a filter containing crushed rock ranging from 4 to 8, considering surface area of 70m²/m³ and a possible area for biofilm formation of 316.7m², while in the other filter was used plastic rings with surface area of 100m²/m³, providing 542.9m² of surface area for biofilm formation. Settlers were constructed after the trickling filters for the removal of suspended solids, because that are not the focus of this research. Considering that the wetness around the filling material is important for system efficiency, it was used a pumping system to transport sewage to the filter, continuously distributed on the support materials and flow split equally for both filters by a distribution system made of perforated PVC with a diameter of 40mm and functioning like a garden sprinkler. The application rate surface ranged from low, intermediate and high, having increased flow in the system until the process of nitrification ended and each phase lasted 180 days. As shown in the results, trickling filters show good efficiency in removing nitrogen from wastewater, either by denitrification by nitrite or by the volatilization of nitrogen. The STEP 1 showed satisfactory results for the filter of crushed rocks over the filter with plastic rings, which may have been caused by the rocks rough area, which facilitated the formation of biofilms, while the smooth surface of the plastic rings makes harder the formation of biofilm, resulting in low efficiency despite the larger surface area. In STEP 3, with higher rates of application, the filter filled with plastic rings showed higher efficiency than the filter with crushed rocks. This might have been a consequence of the greater area available for biofilm formation in plastic rings. Both cases had efficient enough to achieve nitrogen concentrations lower than 20 mg/l. These results demonstrate that the trickling filters have good functionality for removing nitrogen from sanitary wastewater treated systems for waste stabilization ponds.
80

Comportamento de Salmonella em ovo em pó em função da atividade de água (Aa) do binômio tempo x temperatura de armazenamento / Behavior of Salmonella in powdered egg according to its water activity (Aw) and time and temperature of storage

Martin, Gunnar 22 March 2005 (has links)
Salmonella sp. é um dos principais microrganismos causadores de surtos de enfermidades transmitidas por alimentos associados ao consumo de ovos e de alimentos formulados com este ingrediente. Ovos desidratados são largamente utilizados pelas indústrias de alimentos, por oferecer maior praticidade e maior padronização em relação ao produto \"in natura\". Apesar do processo tecnológico de desidratação do ovo incluir uma etapa de pasteurização, existe um risco de haver microrganismos sobreviventes, já que a pasteurização é feita em temperatura branda. Além disso, a pasteurização pode destruir os fatores intrínsecos antimicrobianos presentes na clara, possibilitando a multiplicação de microrganismos que sobreviveram ao processo de pasteurização ou que contaminaram o produto após a pasteurização. O controle da Aa do produto desidratado e o tempo de armazenamento são, portanto, fatores fundamentais para o controle da multiplicação de microrganismos indesejáveis. Nesse estudo, avaliou-se a cinética de multiplicação de Salmonella experimentalmente adicionada a ovo em pó Aa ajustada para 0,4, 0,6, 0,8 e 0,9, durante o armazenamento em quatro temperaturas: 8°C, 15°C, 25°C e 35°C. Os resultados indicaram que S. Enteritidis é capaz de sobreviver por longo tempo (pelo menos 56 dias) em ovo em pó com Aa próximo de 0,4 quando armazenado a 8°C, 15° e a 25°C. Essa sobrevivência é menor (até 28 dias) quando o armazenamento é feito a 35°C. No ovo em pó com Aa em tomo de 0,6 ou 0,8, S. Enteritidis sobrevive por menos tempo do que no produto com Aa de cerca de 0,4, independentemente da temperatura de armazenamento. No produto com Aa de cerca de 0,9, há grande multiplicação de S. Enteritidis quando o armazenamento é feito a 15°C, 25°C ou 35°C. Nesse produto, o armazenamento a 8°C impede a multiplicação do patógeno. Verificou-se também que Salmonella Radar, resistente a diversos antibióticos, apresentou o mesmo comportamento que S. Enteritidis nas amostras de ovo estudadas. / Salmonella is one of the major foodborne pathogens associated to the consumption of eggs and foods containing eggs. Powdered eggs are widely used in the food industry because they are more convenient and uniform than the in natura product. Despite the existence of a pasteurization step in the drying process, Salmonella can survive because the pasteurization of eggs should be done under mild temperature. Moreover, pasteurization can destroy the intrinsic antimicrobial components of the albumen, making the multiplication of Salmonella possible when the time and temperature of storage are not appropriate. Thus, the water activity (Aw) of the product and the storage time and temperature are essential factors in the control of Salmonella. In this work, we evaluated the growth kinetics of Salmonella in experimentally inoculated powdered egg, adjusted to different Aw values (0.4, 0.6, O.S and 0.9) during storage at 8°C, 15°C, 25°C and 35°C, up to 8 weeks. The results indicated that Salmonella Enteritidis is able to survive for long time in powdered eggs (at least 56 days) when the Aw is dose to 0.4 and the temperature is 8°C, or 15°C or 25°C. The survival is lower when the temperature is 35°C. When the Aw is dose to 0.6 or to 0.8, the pathogen survives for less time than in the product with Aw 0.4, regardless the storage temperature. When the Aw is dose to 0.9, there is an intensive growth of the pathogen when the storage is done at 15°C, 25°C or 35°C. However, storage at 8°C inhibits the growth of Salmonella at this Aw. Salmonella Radar, resistant to several antibiotics, presented the same growth partem as S. Enteritidis.

Page generated in 0.0334 seconds