211 |
Avaliação da resistência de união entre dentes artificiais e resinas acrílicas para base protética. Efeito de termociclagemMarra, Juliê [UNESP] 23 March 2007 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:55Z (GMT). No. of bitstreams: 0
Previous issue date: 2007-03-23Bitstream added on 2014-06-13T18:58:02Z : No. of bitstreams: 1
marra_j_me_arafo.pdf: 564454 bytes, checksum: ccab0b66e3c9fe8f4225ae09cf3fc905 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / O estudo avaliou a resistência de união entre dentes artificiais e resinas acrílicas para base protética e o efeito da termociclagem. Para isso foram utilizadas três marcas comerciais de dentes artificiais de resina acrílica (Biotone, Trilux e Ivoclar) e quatro de resinas acrílicas para base protética, sendo duas termopolimerizáveis por banho de água quente (Lucitone 550 e QC-20), uma polimerizada por meio da energia de microondas (Acron MC) e uma fotopolimerizável (Versyo.com). Vinte espécimes foram confeccionados para cada combinação de dente artificial e resina acrílica e divididos em 2 grupos (n=10) nas seguintes condições experimentais: sem a ação da termociclagem (grupo controle) e com a ação da termociclagem. Os espécimes dos grupos com termociclagem foram submetidos 5000 ciclos com temperatura variando entre 4º e 60ºC e tempo de imersão de 30 segundos em cada. Em seguida, os espécimes foram submetidos ao ensaio mecânico de cisalhamento em máquina universal a uma velocidade de 1mm/min. Os dados foram submetidos à análise de variância a três fatores seguida pelo teste de Bonferroni para comparações múltiplas (a=0,05). Os resultados demonstraram que a termociclagem reduziu significantemente os valores médios de resistência de união da resina acrílica Lucitone 550 quando associada aos dentes Biotone e Trilux e com a resina Versyo.com e os dentes Ivoclar P<0,05). E que as médias de resistência de união das resinas acrílicas Acron MC e Lucitone 550 quando associadas aos dentes Ivoclar aumentaram significantemente após a ação da termociclagem (P<0,05). Conclui-se que algumas combinações de dente artificial e resina acrílica podem ser mais afetadas pela ação da termociclagem, e esses efeitos variam de acordo com os materiais selecionados. / The purpose of this in vitro study was to evaluate the bond strength of denture base resins to acrylic denture teeth and the effect of the thermocycling. Three acrylic denture teeth (Biotone, Trilux and Ivoclar) were chosen for bonding to four denture base resins: one microwave-polymerized (Acron MC), two heat-polymerized (Lucitone 550 and QC-20) and one light-polymerized (Versyo.com). Twenty specimens were produced for each denture base/acrylic denture tooth combination and were divided into 2 groups (n=10) as follows: without thermocycling (control groups) and thermocycled groups that were submitted to 5,000 cycles between 4º and 60ºC with a dwell time of 30 seconds in each bath. Shear strength tests (MPa) were performed with a universal testing machine at a crosshead speed of 1 mm/min until fracture. Statistical analysis of the results was carried out with 3-way ANOVA and Bonferroni's multiple comparisons post hoc analysis for test groups (a=.05). A significant interaction between denture base resin, acrylic denture teeth and thermocycling (P<.001) was observed. The shear bond strengths of Lucitone 550/Biotone, Lucitone 550/Trilux and Versyo.com/Ivoclar specimens were significantly decreased by thermocycling compared with the corresponding control groups (P<.05). The shear bond strengths of Acron/Ivoclar and Lucitone/Ivoclar specimens significantly increased after thermocycling (P<.05). Some acrylic tooth/denture base resin combinations can be more affected by thermocycling; the effects vary based upon the materials used.
|
212 |
Avaliação da resistência ao cisalhamento de sistemas para reparo em metalocerâmicasSantos, Juliana Gomes dos [UNESP] 01 December 2004 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:55Z (GMT). No. of bitstreams: 0
Previous issue date: 2004-12-01Bitstream added on 2014-06-13T20:37:52Z : No. of bitstreams: 1
santos_jg_me_arafo.pdf: 726799 bytes, checksum: ba399d198e118a915d5001ecb642c403 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP) / O reparo em próteses metalocerâmicas é um procedimento útil em determinadas situações clínicas. Recentemente surgiram no mercado alguns materiais designados para tal finalidade que, segundo seus fabricantes, são promissores. Neste trabalho foi avaliada a resistência ao cisalhamento de determinados sistemas de reparo para metalocerâmicas. Foram confeccionadas amostras cilíndricas em liga de NiCr (Vera Bond II) e em porcelana feldspática (Noritake). Após inclusão destas em anel de PVC, suas superfícies foram lixadas (320) e, com auxílio de matriz bi-partida (5 mm diâmetro e 2 mm altura), receberam um dos seguintes tratamentos (n=10): 1) sistema Clearfil SE Bond/Clearfil AP-X (Kuraray), 2) sistema Bistite II DC/Palfique (Tokuyama), 3) sistema Cojet Sand/Z100 (3M-ESPE), 4) jateamento com Al2O3 e sistema Scotchbond Multi Uso Plus/Z100 (3M-ESPE) (grupo controle), e 5) jateamento com Cojet Sand e sistema Scotchbond Multi Uso Plus/Z100. Os corpos-de-prova foram armazenados por 24 horas em água destilada a 37ºC, termociclados (1.000 ciclos - 5º a 55ºC) e, então, deixados nas condições descritas acima por mais 8 dias. O ensaio foi realizado em máquina MTS 810 com velocidade de 0,5 mm/min. Os valores originais foram submetidos à análise de variância (ANOVA) e teste de Tukey. No metal, as médias de resistência dos grupos de 1 a 5 foram respectivamente de 18,40 MPa (B), 8,57 MPa (D), 25,24 MPa (A), 16,26 MPa (BC) e de 13,11 MPa (C) (valor crítico 3,2). Em porcelana, foram de 16,91 MPa (B), 18,04 MPa (AB), 19,54 MPa (AB), 21,05 MPa (A) e de 16,18 MPa (B) (valor crítico 3,7). A melhor opção mediante exposição em metal foi o sistema Cojet Sand. Em porcelana, os sistemas Scotchbond Multi Uso Plus associado ao jateamento com Al2O3, Cojet Sand e Bistite II DC apresentaram os melhores resultados. / Fracture of porcelain in metal-ceramic restorations is a common clinical problem and sometimes the repair is a useful solution. Recently some new repair materials with promising results according to their manufactures are available. The aim of this study was to evaluate the shear bond strengths of porcelain repair systems. Fifty disks in NiCr alloy (Vera Bond II) and in feldspatic porcelain (Noritake) were made. The specimens were included in acrylic resin and the surfaces were ground with 320-grit silicon carbide paper. Metal and porcelain specimens were divided into five groups of ten each and the bonding sites received one of the following treatments: 1) Clearfil SE Bond/Clearfil AP-X (Kuraray), 2) Bistite II DC/Palfique (Tokuyama), 3) Cojet Sand System/Z100 (3M-ESPE), 4) air-abrading with Al2O3 and Scotchbond Multi Purpose/Z100 (3M-ESPE) (control group) and 5) air-abrading with Cojet Sand and Scotchbond Multi Purpose/Z100. After storage for 24 hours in distilled water at 37°C, thermocycling (1.000 cycles - 5º and 55ºC) and storage for more 8 days at the same conditions above, the shear bond strength test was performed in a testing machine MTS 810 at a crosshead speed of 0.5mm/min until fracture. Statistical analysis of the data was accomplished by analysis of variance (ANOVA) and Tukey's test. In metal, the bond strengths of groups 1 to 5 were, respectively 18,40 MPa (B), 8,57 MPa (D), 25,24 MPa (A), 16,26 MPa (BC) and 13,11 MPa (C). In porcelain, the bond strengths of the five groups were 16,91 MPa (B), 18,04 MPa (AB), 19,54 MPa (AB), 21,05 MPa (A) and 16,18 MPa (B). The best option when occurs metal exposure is Cojet Sand System. In porcelain, air-abrading with Al2O3 and Scotchbond Multi Purpose, Cojet Sand System and Bistite II DC showed the best results.
|
213 |
Estudo da influência da ciclagem mecânica sobre a resistência de união ao cisalhamento entre uma cerâmica de recobrimento estético e duas cerâmicas infiltradas por vidroLandim, Karine Tenório [UNESP] 23 June 2006 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:28:58Z (GMT). No. of bitstreams: 0
Previous issue date: 2006-06-23Bitstream added on 2014-06-13T19:16:56Z : No. of bitstreams: 1
landim_kt_me_sjc.pdf: 2945410 bytes, checksum: dc611c58884c00b0e53c9d1dcae05bbe (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Este estudo avaliou a influência da ciclagem mecânica na resistência de união ao cisalhamento entre cerâmicas infiltradas por vidro para infra-estrutura (In-Ceram Alumina - Vita Zahnfabrik e In-Ceram Zircônia - Vita Zahnfabrik) e uma cerâmica vítrea de recobrimento (VITA VM7 - Vita Zahnfabrik). Foram preparadas vinte e quatro amostras cilíndricas nas dimensões de 4mm de diâmetro por 5mm de altura para cada cerâmica de infra-estrutura. Posteriormente, a cerâmica de recobrimento estético foi aplicada, resultando em corpos-de-prova com 4mm de diâmetro e 9mm de altura, os quais foram divididos em 4 grupos: ICA; ICAM; ICZ e ICZM. Os grupos ICAM e ICZM receberam ciclagem mecânica, com força de 50N, freqüência de 1Hz, durante 20000 ciclos. O ensaio de cisalhamento foi realizado em máquina de ensaio universal (modelo DL - 1000, EMIC - Equipamentos e Sistemas LTDA., São José dos Pinhais - PR - Brasil) com velocidade de 0,5mm/min e as amostras carregadas até a fratura. As interfaces das amostras pós-fratura foram analisadas em estereomicroscópio (20x) e microscopia eletrônica de varredura. As médias e desvios padrão obtidos foram: ICA (30,04 l 11,74); ICAM (32,17 l 9,59); ICZ (44,33 l 11,47); ICZM (43,52 l 8,33). Os dados obtidos (MPa) foram analisados estatisticamente por meio de análise de variância (ANOVA) dois fatores e teste de Tukey (P<0,05). Os resultados mostraram diferença estatisticamente significante entre os grupos In-Ceram Alumina e In-Ceram Zircônia, porém a ciclagem mecânica não influenciou na resistência de união entre as cerâmicas de infra-estrutura e de recobrimento estético estudadas / This study evaluated the influence of cyclic loading on shear bond strength between two glass-infiltrated ceramics for substructure (In-Ceram Alumina - Vita Zahnfabrik and In-Ceram Zirconia - Vita Zahnfabrik) and one glass veneer ceramic (VITA VM7 - Vita Zahnfabrik). Twenty four cylindrical samples with 4mm diameter per 5mm high was to prepare for each ceramics for substructure. Subsequently, the venner ceramic was applied to ceramic substructure, resulting in 4mm diameter per 9mm high specimens. They were divided in four groups ICA; ICAM; ICZ and ICZM. The groups ICAM and ICZM where cyclic loadind from 50N, 1Hz during 20000 cycles. Shear bond testing was performed in a universal testing machine (DL - 1000 model, EMIC - Equipamentos e Sistemas LTDA., São José dos Pinhais - PR - Brasil), with crosshead speed of 0,5mm/min and the specimens were loaded until failure. The interfaces of representative fractured specimens of each group were examined with microscopy (20x) and scanning electron microscopy. The mean values and standard deviations were: ICA (30,04 l 11,74); ICAM: (32,17 l 9,59); ICZ: (44,33 l 11,47); ICZM: (43,52 l 8,33). Data for shear bond strength (MPa) where statistically analysed by variance analysis (ANOVA) two factors and Tukey's test (P<0,05). The results showed statistically significant differences between the groups In-Ceram Alumina and In-Ceram Zirconia, however the cyclic loading effect was not influenced on bond strength between ceramics for substructure and veneer ceramic studied
|
214 |
Avaliação da resistência ao cisalhamento de sistemas para reparo em metalocerâmicas. Efeito do armazenamento em água /Haneda, Isabella Gagliardi. January 2007 (has links)
Orientador: Renata Garcia Fonseca / Banca: Carlos Alberto dos Santos Cruz / Banca: Mauro Antonio de Arruda Nobilo / Resumo: O reparo de restaurações metalocerâmicas fraturadas pode ser considerado um desafio, principalmente quando grande quantidade de metal é exposta. O estabelecimento de uma união forte e durável entre material reparador e substrato da restauração fraturada é essencial para o sucesso do reparo. Este estudo avaliou a resistência ao cisalhamento entre diferentes sistemas de reparo e liga de NiCr e a durabilidade desta união após armazenamento em água por um longo período. Foram confeccionados 100 discos (9 OE 3 mm) em liga de NiCr. Esses foram incluídos em anel de PVC com resina acrílica e tiveram suas superfícies regularizadas com lixas (120, 220 e 320) em politriz. Cada espécime recebeu um dos seguintes tratamentos: 1) Clearfil SE Bond, 2)Bistite II DC, 3)Cojet, 4) Scotchbond Multi Uso Plus (Grupo controle), e 5) uma variação do Grupo controle, na qual foram empregadas partículas de sílica do sistema Cojet Sand em substituição às de óxido de alumínio. Os espécimes foram armazenados água destilada a 37ºC por 24 horas, termociclados (1.000 ciclos - 5º e 55ºC) e, então, armazenados nas mesmas condições descritas anteriormente, por um período adicional de 24 horas ou 6 meses. O ensaio de cisalhamento foi realizado em máquina de ensaios Material Test System 810 com velocidade de 0,5 mm/minuto. Para cada período de armazenamento, os resultados foram analisados por meio de análise de variância (ANOVA) e teste de Tukey. Para cada sistema, os valores obtidos às 24 horas foram comparados aos encontrados após 6 meses empregando-se teste t de Student não pareado. (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: When clinical fractures of metal-ceramic prostheses occur, exposing the metal substructure, repair may be considered a challenge. The clinical success of repair depends on establishing a strong and long-term durable bond between the repair material and the metal surface of the failed restoration. This study evaluated shear bond strength of different repair systems to NiCr alloy and bond durability after long-term water storage. One hundred cylindrical specimens (9 OE 3 mm) were fabricated in a nickel-chromium alloy. The NiCr cylinders were embedded in a PVC ring and all specimen bonding surfaces were smoothed with silicon carbide papers (120, 220, and 320 grit) using a polisher. Specimens were divided into 5 groups of 20, which received one of the following bonding and resin composite repair systems (n=10): 1) Clearfil SE Bond/Clearfil AP-X, 2) Bistite II DC/Palfique, 3) Cojet /Z100, 4) Scotchbond Multipurpose Plus /Z100 (control group), and 5) Cojet Sand plus Scotchbond Multipurpose Plus /Z100. The specimens were stored in distilled water for 24 hours at 37ºC, thermal cycled (1,000 cycles - 5º to 55ºC) and stored in distilled water at 37ºC for either 24 hours or 6 months. Shear bond tests were performed in a mechanical testing machine with a crosshead speed of 0.5 mm/minute. Data (MPa) were analyzed using 1-way ANOVA and Tukey HSD test (a=.05) for each storage time. The results obtained at 24 hours for each repair system were compared with those found at 6 months using Student's t-test. Each specimen was examined under a stereoscopic lens with OE30 magnification, and mode of failure was classified as adhesive, cohesive or combination. (Complete abstract, click electronic access below) / Mestre
|
215 |
Efeito de tratamento de superfície do titânio comercialmente puro na resistência de união com cimentos ionomérico e resinosos /Abi Rached, Filipe de Oliveira. January 2011 (has links)
Orientador: Renata Garcia Fonseca / Banca: Gelson Luis Adabo / Banca: Paulo Francisco Cesar / Resumo: O titânio, em virtude de suas atrativas propriedades, foi introduzido na área de reabilitação oral podendo ser indicado para a confecção de restaurações metalocerâmicas dento- ou implanto-suportadas. No entanto, apresenta dificuldade de união com materiais resinosos, o que poderia comprometer a longevidade dessas restaurações, considerando a importância da qualidade de união na interface metal/cimento. Para contornar este problema, pode-se lançar mão de tratamentos de superfície do titânio, empregados isoladamente ou em associação. Este estudo avaliou a eficácia de diferentes tratamentos de superfície na resistência ao cisalhamento (RC) da união do cimento ionomérico modificado por resina RelyX Luting 2 e dos cimentos resinosos RelyX ARC e RelyX U100 ao titânio comercialmente puro (Ti cp). Duzentos e quarenta discos (9 x 3 mm) foram fundidos em Ti cp, incluídos em tubos de PVC e regularizados com lixas de carbeto de silício (150, 400 e 600) em politriz. Os espécimes foram divididos aleatoriamente em oito grupos (n=30), os quais receberam um dos seguintes tratamentos de superfície: (1) Al2O3 50 μm; (2) Al2O3 120 μm; (3) Al2O3 250 μm; (4) Al2O3 50 μm + silano; (5) Al2O3 120 μm + silano; (6) Al2O3 250 μm + silano; (7) Cojet Sand (30 μm) + silano; (8) Al2O3 120 μm + Rocatec (110 μm) + silano. Os cimentos (1) RelyX Luting 2; (2) RelyX ARC; (3) RelyX U100 foram aplicados às superfícies tratadas do Ti cp (n=10). Os espécimes foram termociclados (5.000 ciclos, 5 e 55 °C, 30 segundos de imersão) e, então, submetidos ao ensaio de cisalhamento (0,5 mm/min). O modo de fratura foi avaliado em estereomicroscópio (x20). Os dados foram analisados por ANOVA 2 fatores e teste de Tukey (α=0,05). Os cimentos RelyX Luting 2 e RelyX U100 apresentaram comportamento semelhante com relação ao tratamento de superfície... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Titanium was introduced in the field of oral rehabilitation because of its attractive properties, as it can be indicated for fabricating tooth- or implant-supported metal ceramic restorations. However, difficulties have been shown to exist as regards the bond between resin-based materials and titanium, which could compromise the longevity of these restorations, considering the importance of the bond quality at the metal/cement interface. To overcome this problem, titanium surface treatments can be applied alone or they can be combined with each other. This study evaluated the efficacy of different surface treatments on the shear bond strength (SBS) of RelyX Luting 2 resin-modified glass ionomer cement, RelyX ARC and RelyX U100 resin cements to commercially pure titanium (CP Ti). Two hundred and forty discs (9 x 3 mm) were cast from CP Ti, embedded in PVC tubes and smoothed with silicon carbide papers (150, 400 and 600) using a polisher. Specimens were randomly divided into 8 groups (n=30), which received one of the following surface treatments: (1) 50 μm Al2O3; (2) 120 μm Al2O3; (3) 250 μm Al2O3; (4) 50 μm Al2O3 + silane; (5) 120 μm Al2O3 + silane; (6) 250 μm Al2O3 + silane; (7) Cojet Sand (30 μm) + silane; (8) 120 μm Al2O3 + Rocatec (110 μm) + silane. The luting cements (1) RelyX Luting 2; (2) RelyX ARC; (3) RelyX U100 were applied to the treated CP Ti surfaces (n=10). Specimens were thermal cycled (5,000 cycles, 5 and 55 °C, 30-second dwell time), and afterwards submitted to SBS testing (0.5 mm/min). Failure mode was evaluated under a stereomicroscope (x20). Data were analyzed using 2-way ANOVA and Tukey's test (α=0.05). The RelyX Luting 2 and RelyX U100 luting cements exhibited similar behavior regards to the surface treatment. For both, only the group abraded with 50 μm Al2O3 particles promoted lower SBS than the other groups (P>.05)... (Complete abstract click electronic access below) / Mestre
|
216 |
Mechanical behaviour of fibre reinforced unsaturated clay : this investigation is to determine the improvement in the mechanical behaviour of unsaturated clayey soil after inclusion of carpet fibre wasteSaad, Suleiman S. E. January 2016 (has links)
To acquire deeper understanding and insights into the mechanical behaviour of fibre reinforced saturated/unsaturated cohesive soils, a programme of work was designed and included. 1) Conducting standard Consolidation Undrained (CU) tests to investigate mechanical behaviour of non-reinforced fully saturated soil. 2) Studying the strength of fibre reinforced clay though unconfined compression tests. 3) Testing the behaviour of unsaturated reinforced soil in unsaturated triaxial tests. 4) Determining the soil-water characteristic curves (SWCC) on soil sample with different fibre content. The investigation was undertaken on a clay of low plasticity index. Samples tested with addition of 1, 3 and 5 % fibre content and different values of matric suction of 50, 100 and 200 kPa, one of the challenges that were encountered in this research are how to prepare homogenous samples. A method for prepared compacted fibre reinforced soils with improved fibre distribution and density profile has been proposed and examined. The test results indicated that waste carpet fibres increase the shear strength of unsaturated clay soils. It was also found that relative increase in strength is also a function of applied suction. An increase in waste carpet fibres was found to reduce the hysteresis of soil. A data analysis conducted on the results of unsaturated tests as a function of fibre content and matric suction. The behaviour modelled was shown to be a perfect fit with the experimental data.
|
217 |
Mecanismos de penetração dinâmica em solos granulares / Dynamic penetration mechanisms in cohesionless soilsLobo, Bianca de Oliveira January 2009 (has links)
Ensaios de penetração dinâmica são ferramentas de investigação geotécnica de fácil execução e baixo custo. Estas características tornaram o ensaio SPT na técnica de investigação mais utilizada em diversos países como Canadá, Estados Unidos, Japão e principalmente, no Brasil. Em contrapartida, a penetração dinâmica de amostradores produz um complexo mecanismo de reação do solo, função da energia entregue ao sistema e da capacidade de absorção desta energia pelo próprio solo. Na prática de engenharia, este mecanismo é simplificado através do uso de abordagens empíricas. Pesquisas na década de 1970, realizadas por Schmeertmmann & Palacius (1979) e Schmertmmann (1979), avaliaram a energia inserida no sistema haste-amostrador objetivando a padronização do ensaio SPT para diferentes equipamentos e procedimentos. Pesquisas recentes de interpretação do ensaio utilizam conceitos de conservação de energia e trabalho realizado pelo amostrador ao penetrar no solo, visando equacionar a resistência mobilizada (eg. Oderebrecht, 2003; Odebrecht et al, 2005; Schnaid, 2005). Na presente pesquisa, são utilizados os conceitos de conservação de energia, associados com equações de equilíbrio dinâmico e com a teoria de expansão de cavidades (Vésic, 1972) para desenvolver uma rotina de simulação numérica capaz de modelar os principais mecanismos de reação do solo devido cravação de um amostrador. A partir da validação da rotina de simulação numérica para ensaios dinâmicos de distintas geometrias (ensaios SPT, ILPT, NALPT e RLPT), avalia-se a variabilidade da energia entregue ao solo devido às diferenças de compacidade do solo, eficiência do golpe, geometria do martelo, tipo e comprimento da composição de hastes. Destas simulações, é possível observar as diferenças de resultados entre ensaios de distintas geometrias de martelo e composição de hastes, concluindo-se que pequenas variações geométricas produzem diferenças no índice de resistência à penetração. Como conseqüência, sugere-se que a interpretação dos resultados depende de um método racional de análise capaz de incorporar estes efeitos à estimativa de propriedades de comportamento de solos. Na identificação dos mecanismos de ruptura para solos de diferentes compacidades foram desenvolvidas duas metodologias que permitem estimar a resistência ao cisalhamento de solos granulares a partir do índice de resistência à penetração medida em ensaios de penetração dinâmica. A primeira metodologia utiliza a rotina de simulação numérica desenvolvida através de uma análise do Problema do valor inverso, enquanto a segunda proposta utiliza os pressupostos do Teorema de Buckingham no estabelecimento de uma solução analítica que permita estimar o ângulo de atrito de pico de materiais granulares. As duas alternativas foram validadas através de estudo de casos, permitindo concluir que as soluções produzem estimativas de ângulo de atrito realistas, de mesma ordem de magnitude que outras abordagens difundidas no meio técnico e compatíveis com resultados de ensaios de campo e laboratório. / Dynamic penetration tests are simple, economic and easily performed geotechnical investigation tools. Due to these general characteristics, the test has been used systematically in many countries such as Canada, United States, Japan and Brazil. Despite the attractive conditions of performing a simple test, dynamic penetration of a any tool into a soil mass produces a complex soil reaction mechanism that depends on the energy delivered to the soil, as well as the capability of the soil to absorb this energy. Given this complexity a simple approach of interpreting the test by using empirical correlations has prevailed. In 1970, Schmeertmmann & Palacius (1979) and Schmertmmann (1979) develop the first rational methodology to compute the energy delivered to the rod-sampler system that has been incorporated to engineering practice by normalizing different practices in terms of a reference energy. Most recent researches of SPT test interpretation make uses of energy concepts and work to compute the mobilized soil-resistance due to the sampler penetration (e.g. Oderebrecht, 2003; Odebrecht et al, 2005; Schnaid, 2005). In present research these recent approaches are extended through the use of energy concepts associated with dynamic equilibrium equations and cavity expansion theory (Vésic, 1972). Constitutive equations have been incorporated to a numerical simulation routine able to reproduce the some of the most important processes of soil reaction during dynamic in cohesionless soil. The model validation for different dynamic penetration test geometries (SPT, ILPT, NALPT and RLPT) enabled the energy delivered to soil to be evaluated and the effects of soil density, blow efficiency, hammer geometry, rod type and length to be assessed. From a number of simulations, it was possible to describe the differences related typical geometrical changes (i.e. hammer length, rod cross section and length). Conclusions from the analysis are that small geometrical changes in hammer and rod characteristics - typically observed in different SPT practices - produce differences into the measured blow count. As consequence, it is suggested that interpretation of dynamic penetration test results will depend on a model capable of incorporating all these effects when attempting to derive soil constitutive parameters. This is one of the outputs of the present study that lead to the development of two rational methodologies to assess the internal friction angle of cohesionless soils from dynamic penetration blow count. The first one uses the numerical simulation routine as a Inverse Boundary Value problem while the second one uses the Buckingham’s Theorem to develop an analytical equations that correlates the N-SPT with the soil shear strength. Both methodologies have been validated by a series of case studies designed to demonstrate that the proposed solution produces friction angle values of the same order of magnitude of other approaches and compatible to measurements produced by laboratory and in situ tests.
|
218 |
Resistência ao microcisalhamento de diferentes sistemas adesivos no esmalte dental humano /Nagayassu, Marcos Paulo. January 2007 (has links)
Orientador: Marcelo Fava de Moraes / Banca: Victor Elias Arana Chavez / Banca: Matsuyoshi Mori / Banca: Silvio Issáo Myaki / Banca: Lafayette Nogueira Junior / Resumo: O objetivo deste estudo foi avaliar in vitro a resistência ao microcisalhamento de 5 sistemas adesivos ao esmalte, sendo 1 adesivo monocomponente (M), 2 primers autocondicionantes (P) e 2 adesivos autocondicionantes (A). Foram utilizadas 60 faces (vestibular ou lingual) de pré-molares, aplainadas com lixas d'água (400 e 600) e divididas aleatoriamente em 5 grupos (n=12), de acordo com o adesivo utilizado: SB2- Single Bond2 (M); CSE- Clearfil SE Bond (P); ADS- AdheSE (P); PLP- Adper Prompt L-Pop (A); XE3- Xeno III (A). Tubos de Tygon delimitaram a área de adesão em 0,8mm de diâmetro, para se obter os cilindros de resina composta (Z250). Após armazenamento em água destilada a 37ºC por 24h e termociclagem, foi realizado o teste de microcisalhamento (velocidade de 0,5mm/min).). Os dados foram submetidos aos testes de ANOVA e Tukey ('alfa'=5%). Os valores de média (MPa'mais ou menos'DP) e os resultados do teste de Tukey foram: SB2: 36,36('mais ou menos'3,34)a; ADS: 33,03('mais ou menos'7,83)a; XE3: 32,76('mais ou menos'5,61)a; CSE: 30,61('mais ou menos'6,68)a; PLP: 22,17('mais ou menos'6,05)b. Grupos com a mesma letra não apresentaram diferenças significantes. Pode-se concluir que não houve diferença estatística entre SB2, ADS, XE3 e CSE, apesar dos diferentes padrões de condicionamento destes adesivos. Apenas o PLP apresentou valores médios de adesão inferiores aos demais. / Abstract:The aim of this in vitro study was to evaluate the micro-shear bond strength of 5 adhesive systems to enamel, one single-bottle acid-etch adhesive (O), two selfetching primers (P) and two all-in-one self-etching adhesives (S). Sixty premolar enamel surfaces (buccal or lingual) were ground flat with 400- and 600-grit SiC papers and randomly divided into 5 groups (n=12), according to adhesive system: SB2 - Single Bond 2 (O); CSE - Clearfil SE Bond (P); ADS - AdheSE (P); PLP - Adper Prompt L-Pop (S); XE3 - Xeno III (S). Tygon tubing (internal diameter of 0,8mm) restricted the bonding area to obtain the resin composite (Z250) cylinders. After storage in distilled water at 37oC for 24h and thermocycling, micro-shear testing was performed (crosshead speed of 0.5mm/min). Data were submitted to one-way ANOVA and Tukey test ('alfa'=5%). Mean bond strength values (MPa'mais ou menos'SD) and the results of Tukey test were: SB2: 36.36('mais ou menos'3.34)a; ADS: 33.03('mais ou menos'7.83)a; XE3: 32.76('mais ou menos'5.61)a; CSE: 30.61('mais ou menos'6.68)a; PLP: 22.17('mais ou menos'6.05)b. Groups with the same letter were not statistically different. It can be concluded that no significant difference was there between SB2, ADS, XE3 and CSE, in spite of different etching patterns of these adhesives. Only PLP presented statistically lower bond strengths compared with others. / Doutor
|
219 |
Desenvolvimento de um equipamento triaxial de grande porte para avaliação de agregados utilizados como camada de pavimentos / Development of triaxial equipment for testing large specimens of unbound aggregates for paving purposesMalysz, Rodrigo January 2009 (has links)
Camadas granulares desempenham um importante papel no comportamento global de pavimentos, especialmente daqueles com revestimentos delgados ou sem revestimento. Para conhecer as características de resistência e deformabilidade de materiais componentes dessas camadas são realizados ensaios triaxiais. No caso de ensaios em materiais granulares, o corpo de prova deve ter diâmetro de pelo menos cinco vezes o tamanho máximo de partícula e altura igual a duas vezes o seu diâmetro. Como as especificações do DNIT permitem o emprego de agregados de até 5 cm em camadas de brita graduada ou solo-agregado, os corpos-de-prova devem ter diâmetro de 25 cm e altura de 50 cm. Equipamentos capazes de ensaiar corpos-deprova com estas dimensões são raros no mundo e inexistiam no Brasil até 2008. Com o intuito de superar esta carência e avançar no conhecimento do comportamento mecânico de agregados graúdos, a pesquisa relatada nesta tese teve como objetivos desenvolver um equipamento triaxial de grande porte capaz de aplicar carregamentos estáticos, monotônicos e cíclicos em corpos-de-prova de grandes dimensões (25 cm x 50 cm); bem como realizar e interpretar os primeiros ensaios. A concepção e a montagem do equipamento são descritas considerando as partes principais. Também é detalhada a instrumentação utilizada composta por: duas células de carga, três transdutores de deslocamento e dois transmissores de pressão. Para os primeiros ensaios foi escolhida uma brita graduada de basalto, anteriormente utilizada em pistas experimentais solicitadas por simulador de tráfego. Ensaios em corpos-de-prova de 10 cm de diâmetro e 20 cm de altura foram realizados para comparação com resultados de ensaios em corpos-de-prova maiores, realizados no novo equipamento. Os ensaios de módulo de resiliência foram conduzidos segundo o método de ensaio do DNIT, com algumas modificações para adequá-lo ao padrão internacional. Os ensaios triaxiais monotônicos e os cíclicos de deformações permanentes foram conduzidos tanto em multiestágios, quanto em estágio único de tensões. Os resultados obtidos foram interpretados segundo diversas teorias e modelos, obtendo-se parâmetros de resistência e de deformabilidade. Uma análise mecanística utilizando os parâmetros obtidos nos ensaios permitiu analisar o comportamento do material estudado como camada de pavimento. Conclui-se que o equipamento triaxial de grande porte atende as necessidades para as quais foi projetado, permitindo obter parâmetros para caracterização do comportamento de agregados graúdos e prever desempenho de pavimentos, quanto a deformações permanentes e ruptura por cisalhamento de camadas granulares. / Unbound aggregates layers play an important role in the performance of thinly surfaced or unsurfaced pavements. In order to assess the strength-strain characteristics of soils and aggregates used in those layers, triaxial tests must be carried out on cylindrical specimens with diameter not smaller than 5 times the particle maximum size and height twice the diameter. Since Brazil National Roads Department allows using 2” aggregates in granular bases, specimens for triaxial tests should be at least 25 cm in diameter and 50 cm in height. All over the world there are only a few equipments for testing such specimens; and up to 2008 none of them in Brazil. Aiming at overcoming this deficiency and enhance the knowledge on the mechanical behavior of coarse aggregates, the objectives of research reported in this thesis were to develop a triaxial equipment capable of applying static, monotonic and repeated loadings on large specimens (25 cm x 50 cm) and perform and analyze the first tests. The design and assemblage of the equipment are describe, detailing its main components and the instrumentation, that included two load cells, three displacement transducers and two pressure transmitters. The first tests were carried out on specimens made of dense crushed aggregates, formerly used in APT test sections. Tests were also carried out on specimens with 10.0 cm diameter and 20.0 cm height, in order to compare their results to those of tests carried out in larger specimens tested in the new triaxial equipment. Resilient modulus tests were carried out according to the Brazilian standard, but some modifications were introduced to follow international patterns. Triaxial monotonic and repeated loading permanent deformation tests were carried out both in multiple stages and unique stage of stresses. The results were interpreted were calculated taking into account several theories and models, strength and strain parameters being obtained. A mechanistic analysis using parameters obtained in tests allowed analyzing the behavior of the studied aggregates making part of pavement layers. It is concluded the new triaxial equipment for large specimens fulfills the requirements that motivated its design and construction, making possible to obtain parameters for characterizing the behavior of coarse aggregates and estimating pavements performance regarding permanent deformation and shear failure of granular layers.
|
220 |
Nova abordagem para previsão de parâmetros de resistência ao cisalhamento de uma areia artificialmente cimentadaSachetti, Álisson Silveira January 2014 (has links)
É extremamente comum que o solo de uma determinada região não tenha os parâmetros geotécnicos favoráveis a implementação de projetos de pavimentação e fundações. Com o passar do tempo, o homem ocupou praticamente todos os locais onde as características do solo são favoráveis à construção civil, principalmente nos grandes centros urbanos, restando os locais que desafiam os projetistas a fazerem obras de baixo custo e qualidade técnica. Com intuito de solucionar este problema, vários trabalhos estão sendo desenvolvidos através da técnica de melhoramento ou estabilização de solos com agentes cimentantes. Deste modo, o presente trabalho teve como objetivo validar uma nova abordagem para a obtenção de parâmetros de resistência ao cisalhamento de uma areia artificialmente cimentada. Para aplicação desta abordagem, utilizou-se resultados de compressão simples e diametral, sendo estes comparados com os resultados obtidos a partir de ensaios de compressão triaxial consolidados e drenados com as mesmas características dos ensaios de compressão não confinada. Com o intuito de enriquecer o conhecimento sobre o assunto, também foram aplicados outros modelos de previsão de resistência ao cisalhamento, tais como, o critério de ruptura de Griffith (1921) e o modelo experimental de Mitchell (1981). Para isto, o solo utilizado foi uma areia de granulometria fina com adição de Cimento Portland CPV-ARI, com três diferentes porcentagens de cimento em relação a massa de solo seco (3, 5,1 e 8,6) e, para tempos de cura de 03, 07, 28 e 90 dias. Baseados nos resultados obtidos através deste trabalho, concluiu-se que: quanto ao comportamento tensão-deformação, os ensaios apresentaram pico de resistência bem definido com comportamento de material rígido e queda acentuada da resistência após a ruptura; quanto a utilização da nova abordagem proposta, os parâmetros de resistência do modelo quando comparados com os resultados obtidos pelos ensaios triaxiais foram satisfatórios, deste modo validando esta metodologia. O emprego da teoria de Griffith e do modelo de Mitchell, não apresentaram resultados com a mesma qualidade obtida pela nova abordagem proposta. / It is extremely common that the soil of a particular region does not have the favorable geotechnical parameters for implementing paving and foundations projects. With the passage of time men has occupied virtually all locations where soil characteristics are favorable for constructions, especially in large urban centers, leaving the places that challenge engineers to design works of low cost and technical quality. In order to solve this problem, several studies are being developed through soil improvement and stabilization technique with cementing agents. Thus, the present study aimed to validate a new approach to obtain shear strength parameters of an artificially cemented sand. To apply this approach, results of unconfined compression tests were used, which were compared to the results obtained from consolidated and drained triaxial compression tests, with the same characteristics of the unconfined compressive tests. In order to enrich the knowledge on this subject, other models were applied to predict parameters of resistance, such as the Griffith (1921) failure criterion and the experimental model of Mitchell (1981). The soil used was a fine grained sand with addition of Portland cement CPV-ARI, with 3.00, 5.06 and 8.60 percentage of cement in relation to the mass of dry soil at curing times of 03, 07, 28 and 90 days. Based on the results obtained through this work, it was concluded that the use of the new approach proposed is valid because the strength parameters of the model when compared with the results obtained by the triaxial tests were satisfactory. The use of the Griffith theory and Mitchell model did not obtain results with the same quality obtained by the new approach proposed. Regarding the stress-strain behavior, the triaxial tests showed peak strength with well-defined behavior of rigid material and sharp drop in resistance after the rupture.
|
Page generated in 0.0826 seconds