• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 14
  • 5
  • 1
  • Tagged with
  • 22
  • 22
  • 14
  • 8
  • 8
  • 8
  • 7
  • 6
  • 6
  • 6
  • 5
  • 4
  • 4
  • 4
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Propriedades físico-químicas de uma nova formulação de cimento biocerâmico

Mendes, Aline Teixeira January 2017 (has links)
O sucesso do tratamento endodôntico a longo prazo depende do preparo químico mecânico e também da obturação dos sistemas de canais radiculares, que tem como objetivo prover o preenchimento de forma tridimensional com um material inerte. Um cimento endodôntico ideal deve ser biocompatível, ter tempo de presa adequado, estabilidade dimensional, união à dentina, baixa solubilidade, fácil manuseio e ser radiopaco. Para estabelecer um padrão nas pesquisas de materiais odontológicos algumas especificações são determinadas pela ISO e ANSI/ADA, onde são determinados os testes a serem realizados para cada tipo de material a ser avaliado. O objetivo desse estudo foi avaliar as propriedades físico-químicas de um novo cimento à base de silicato de cálcio tendo como fonte de comparação um cimento à base de resina epóxi. Para a avaliação do pH e liberação de cálcio, tubos de polietileno de 1mm de diâmetro interno e 10 mm de comprimento foram preenchidos com os cimentos e imersos em 10 ml de água deionizada. Após os períodos experimentais de 1, 24, 72 e 168 horas as amostras foram avaliadas quanto ao pH e a liberação de cálcio em um medidor de pH e espectrofotômetro colorimétrico respectivamente. Na análise da radiopacidade, solubilidade e tempo de presa foram confeccionados anéis com 10mm de diâmetro e 1mm de espessura do cimento; o valor da radiopacidade foi determinado de acordo com a densidade radiográfica (mm Al). Para a solubilidade os espécimes foram imersos em 50ml de água destilada por 7 dias, onde foi aferida a massa inicial (antes da imersão) e a final (após a imersão e desumidificação). A avaliação do tempo de presa foi realizada com agulhas Gilmore de 100g e 456,3g. O escoamento foi realizado com base na ISO 6876:2001. Os dados foram analisados por análise de variância e teste de Tukey (P<0,05). Os resultados encontrados nesse estudo, para valores de pH e Ca- foram significativamente maiores para o cimento Biosealer quando comparados ao AH Plus (P<0,05). Nos testes de escoamento, radiopacidade e tempo de presa o cimento biocerâmico demonstrou valores inferiores ao AH Plus (P<0,05). O Biosealer demonstrou uma alta solubilidade comparativamente ao AH Plus (P<0,05). É lícito concluir que, o cimento Biosealer demonstrou boas propriedades físico-químicas tais como; pH, liberação de cálcio, escoamento, radiopacidade e tempo de presa. Essa nova formulação de cimento endodôntico apresentou uma maior solubilidade do que a prevista na ISO 6876:2012. / The success of long-term endodontic treatments depend on mechanical and chemical preparation, as well as on the root canal fillings, the purpose of which being providing filling in a three-dimensional fashion using inert material. The ideal endodontic cement must be biocompatible, have an appropriate setting time, dimensional stability, dentin bond strength, low solubility, be easy to manipulate and radiopaque. In order to set up a standard for research involving dental materials, some specifications are set forth by ISO and ANSI/ADA, in which the tests to be carried out for each material to be assessed are provided for. The goal of this study is to assess the physical and chemical properties of a new calcium silicate-based cement, to be compared with an epoxy resin-based cement. In order to assess calcium release and pH levels, polyethylene tubes with internal diameter of 1 mm and 10 mm in length have been filled with the cements and immersed in 10 ml of deionized water. After trial periods of 1, 24, 72 and 168 hours, the samples were assessed with regard to their calcium release and pH levels, using a colorimetric spectrophotometer and a pH mete, respectively. In order to assess radiopacity, solubility and setting time, rings with 10 mm in diameter and 1 mm in thickness were manufactured using the cements; the radiopacity levels were calculated in accordance with their radiographic density (mm Al). In order to assess solubility, the items were immersed in 50 ml of distilled water for seven days, with the initial mass (before immersion) and final mass (after immersion and dehumidification) being measured. The setting time assessment was carried out using Gilmore needles weighing 100 g and 456.3 g. Yield test was carried out based on ISO 6876:2001. The data obtained were analyzed through analysis of variance and Tukey test (P<0.05). The results found in this study with regard to pH e Ca- levels were significantly higher for the Biosealer cement, when compared with AH Plus (P<0.05). In the yield, radiopacity and setting time tests, the results for the bioceramic cement were lower when compared with AH Plus (P<0.05). The results for the Biosealer indicated higher solubility levels, when compared with AH Plus (P<0.05). It is conceivable to conclude that the Biosealer has shown good physical-chemical properties, such as pH, calcium release, yield, radiopacity and setting time. This new endodontic cement formulation has shown a higher solubility when compared with the level set forth in ISO 6876:2012.
12

Laboratory study on cavity liners as protectors of the pulp against the effect of silicate cement a thesis submitted in partial fulfillment ... [operative dentistry] /

Segat, Leon. January 1948 (has links)
Thesis (M.S.)--University of Michigan, 1948.
13

Propriedades físico-químicas de uma nova formulação de cimento biocerâmico

Mendes, Aline Teixeira January 2017 (has links)
O sucesso do tratamento endodôntico a longo prazo depende do preparo químico mecânico e também da obturação dos sistemas de canais radiculares, que tem como objetivo prover o preenchimento de forma tridimensional com um material inerte. Um cimento endodôntico ideal deve ser biocompatível, ter tempo de presa adequado, estabilidade dimensional, união à dentina, baixa solubilidade, fácil manuseio e ser radiopaco. Para estabelecer um padrão nas pesquisas de materiais odontológicos algumas especificações são determinadas pela ISO e ANSI/ADA, onde são determinados os testes a serem realizados para cada tipo de material a ser avaliado. O objetivo desse estudo foi avaliar as propriedades físico-químicas de um novo cimento à base de silicato de cálcio tendo como fonte de comparação um cimento à base de resina epóxi. Para a avaliação do pH e liberação de cálcio, tubos de polietileno de 1mm de diâmetro interno e 10 mm de comprimento foram preenchidos com os cimentos e imersos em 10 ml de água deionizada. Após os períodos experimentais de 1, 24, 72 e 168 horas as amostras foram avaliadas quanto ao pH e a liberação de cálcio em um medidor de pH e espectrofotômetro colorimétrico respectivamente. Na análise da radiopacidade, solubilidade e tempo de presa foram confeccionados anéis com 10mm de diâmetro e 1mm de espessura do cimento; o valor da radiopacidade foi determinado de acordo com a densidade radiográfica (mm Al). Para a solubilidade os espécimes foram imersos em 50ml de água destilada por 7 dias, onde foi aferida a massa inicial (antes da imersão) e a final (após a imersão e desumidificação). A avaliação do tempo de presa foi realizada com agulhas Gilmore de 100g e 456,3g. O escoamento foi realizado com base na ISO 6876:2001. Os dados foram analisados por análise de variância e teste de Tukey (P<0,05). Os resultados encontrados nesse estudo, para valores de pH e Ca- foram significativamente maiores para o cimento Biosealer quando comparados ao AH Plus (P<0,05). Nos testes de escoamento, radiopacidade e tempo de presa o cimento biocerâmico demonstrou valores inferiores ao AH Plus (P<0,05). O Biosealer demonstrou uma alta solubilidade comparativamente ao AH Plus (P<0,05). É lícito concluir que, o cimento Biosealer demonstrou boas propriedades físico-químicas tais como; pH, liberação de cálcio, escoamento, radiopacidade e tempo de presa. Essa nova formulação de cimento endodôntico apresentou uma maior solubilidade do que a prevista na ISO 6876:2012. / The success of long-term endodontic treatments depend on mechanical and chemical preparation, as well as on the root canal fillings, the purpose of which being providing filling in a three-dimensional fashion using inert material. The ideal endodontic cement must be biocompatible, have an appropriate setting time, dimensional stability, dentin bond strength, low solubility, be easy to manipulate and radiopaque. In order to set up a standard for research involving dental materials, some specifications are set forth by ISO and ANSI/ADA, in which the tests to be carried out for each material to be assessed are provided for. The goal of this study is to assess the physical and chemical properties of a new calcium silicate-based cement, to be compared with an epoxy resin-based cement. In order to assess calcium release and pH levels, polyethylene tubes with internal diameter of 1 mm and 10 mm in length have been filled with the cements and immersed in 10 ml of deionized water. After trial periods of 1, 24, 72 and 168 hours, the samples were assessed with regard to their calcium release and pH levels, using a colorimetric spectrophotometer and a pH mete, respectively. In order to assess radiopacity, solubility and setting time, rings with 10 mm in diameter and 1 mm in thickness were manufactured using the cements; the radiopacity levels were calculated in accordance with their radiographic density (mm Al). In order to assess solubility, the items were immersed in 50 ml of distilled water for seven days, with the initial mass (before immersion) and final mass (after immersion and dehumidification) being measured. The setting time assessment was carried out using Gilmore needles weighing 100 g and 456.3 g. Yield test was carried out based on ISO 6876:2001. The data obtained were analyzed through analysis of variance and Tukey test (P<0.05). The results found in this study with regard to pH e Ca- levels were significantly higher for the Biosealer cement, when compared with AH Plus (P<0.05). In the yield, radiopacity and setting time tests, the results for the bioceramic cement were lower when compared with AH Plus (P<0.05). The results for the Biosealer indicated higher solubility levels, when compared with AH Plus (P<0.05). It is conceivable to conclude that the Biosealer has shown good physical-chemical properties, such as pH, calcium release, yield, radiopacity and setting time. This new endodontic cement formulation has shown a higher solubility when compared with the level set forth in ISO 6876:2012.
14

Análise de cimentos à base de silicato de cálcio associado a diferentes radiopacificadores /

Costa, Bernardo Cesar. January 2016 (has links)
Orientador: Mario Tanomaru-Filho / Resumo: O MTA e cimento Portland (PC) são cimentos de silicato de cálcio. O óxido de bismuto presente na MTA pode afetar as propriedades físico-químicas e biológicas do material. Novos radiopacificadores como óxido de itérbio (Yb2O3) e o tungstato de cálcio (CaWO4) podem melhorar propriedades do material. No capítulo 1, foram realizadas avalições de propriedades físico-químicas, citotoxicidade e potencial bioativo do MTA Angelus (MTA), cimento de silicato de cálcio (CSC) e CSC com 30% de óxido de Itérbio (CSC/Yb2O3). O tempo de presa inicial e final foi avaliado com agulhas Gilmore. A resistência à compressão foi analisada em máquina de ensaios mecânicos. A radiopacidade foi verificada com radiografias dos materiais e escala de alumínio. O teste de solubilidade e escoamento foram realizados de acordo com ISO 6876/2002. Os dados foram submetidos ao teste ANOVA e Tukey (5% de significância). A viabilidade celular foi avaliada por meio do ensaio MTT e corante Vermelho Neutro, enquanto o potencial de mineralização por meio da atividade de fosfatase alcalina e vermelho de Alizarina. Os dados foram submetidos aos testes Anova e Tukey e Bonferroni (5% de significância). O potencial bioativo foi avaliado em microcopia eletrônica de varredura. No capítulo 2, materiais à base de silicato tricálcico (TSC) associado ao tungstato de cálcio (CaWO4) e Yb2O3 foram avaliados em comparação ao MTA (Angelus, Londrina, Brasil) e ao TSC. O tempo de presa inicial e final foi avaliado com agulhas Gilmore. A... (Resumo completo, clicar acesso eletrônico abaixo) / Doutor
15

Propriedades físico-químicas de uma nova formulação de cimento biocerâmico

Mendes, Aline Teixeira January 2017 (has links)
O sucesso do tratamento endodôntico a longo prazo depende do preparo químico mecânico e também da obturação dos sistemas de canais radiculares, que tem como objetivo prover o preenchimento de forma tridimensional com um material inerte. Um cimento endodôntico ideal deve ser biocompatível, ter tempo de presa adequado, estabilidade dimensional, união à dentina, baixa solubilidade, fácil manuseio e ser radiopaco. Para estabelecer um padrão nas pesquisas de materiais odontológicos algumas especificações são determinadas pela ISO e ANSI/ADA, onde são determinados os testes a serem realizados para cada tipo de material a ser avaliado. O objetivo desse estudo foi avaliar as propriedades físico-químicas de um novo cimento à base de silicato de cálcio tendo como fonte de comparação um cimento à base de resina epóxi. Para a avaliação do pH e liberação de cálcio, tubos de polietileno de 1mm de diâmetro interno e 10 mm de comprimento foram preenchidos com os cimentos e imersos em 10 ml de água deionizada. Após os períodos experimentais de 1, 24, 72 e 168 horas as amostras foram avaliadas quanto ao pH e a liberação de cálcio em um medidor de pH e espectrofotômetro colorimétrico respectivamente. Na análise da radiopacidade, solubilidade e tempo de presa foram confeccionados anéis com 10mm de diâmetro e 1mm de espessura do cimento; o valor da radiopacidade foi determinado de acordo com a densidade radiográfica (mm Al). Para a solubilidade os espécimes foram imersos em 50ml de água destilada por 7 dias, onde foi aferida a massa inicial (antes da imersão) e a final (após a imersão e desumidificação). A avaliação do tempo de presa foi realizada com agulhas Gilmore de 100g e 456,3g. O escoamento foi realizado com base na ISO 6876:2001. Os dados foram analisados por análise de variância e teste de Tukey (P<0,05). Os resultados encontrados nesse estudo, para valores de pH e Ca- foram significativamente maiores para o cimento Biosealer quando comparados ao AH Plus (P<0,05). Nos testes de escoamento, radiopacidade e tempo de presa o cimento biocerâmico demonstrou valores inferiores ao AH Plus (P<0,05). O Biosealer demonstrou uma alta solubilidade comparativamente ao AH Plus (P<0,05). É lícito concluir que, o cimento Biosealer demonstrou boas propriedades físico-químicas tais como; pH, liberação de cálcio, escoamento, radiopacidade e tempo de presa. Essa nova formulação de cimento endodôntico apresentou uma maior solubilidade do que a prevista na ISO 6876:2012. / The success of long-term endodontic treatments depend on mechanical and chemical preparation, as well as on the root canal fillings, the purpose of which being providing filling in a three-dimensional fashion using inert material. The ideal endodontic cement must be biocompatible, have an appropriate setting time, dimensional stability, dentin bond strength, low solubility, be easy to manipulate and radiopaque. In order to set up a standard for research involving dental materials, some specifications are set forth by ISO and ANSI/ADA, in which the tests to be carried out for each material to be assessed are provided for. The goal of this study is to assess the physical and chemical properties of a new calcium silicate-based cement, to be compared with an epoxy resin-based cement. In order to assess calcium release and pH levels, polyethylene tubes with internal diameter of 1 mm and 10 mm in length have been filled with the cements and immersed in 10 ml of deionized water. After trial periods of 1, 24, 72 and 168 hours, the samples were assessed with regard to their calcium release and pH levels, using a colorimetric spectrophotometer and a pH mete, respectively. In order to assess radiopacity, solubility and setting time, rings with 10 mm in diameter and 1 mm in thickness were manufactured using the cements; the radiopacity levels were calculated in accordance with their radiographic density (mm Al). In order to assess solubility, the items were immersed in 50 ml of distilled water for seven days, with the initial mass (before immersion) and final mass (after immersion and dehumidification) being measured. The setting time assessment was carried out using Gilmore needles weighing 100 g and 456.3 g. Yield test was carried out based on ISO 6876:2001. The data obtained were analyzed through analysis of variance and Tukey test (P<0.05). The results found in this study with regard to pH e Ca- levels were significantly higher for the Biosealer cement, when compared with AH Plus (P<0.05). In the yield, radiopacity and setting time tests, the results for the bioceramic cement were lower when compared with AH Plus (P<0.05). The results for the Biosealer indicated higher solubility levels, when compared with AH Plus (P<0.05). It is conceivable to conclude that the Biosealer has shown good physical-chemical properties, such as pH, calcium release, yield, radiopacity and setting time. This new endodontic cement formulation has shown a higher solubility when compared with the level set forth in ISO 6876:2012.
16

AVALIAÇÃO DA GENOTOXICIDADE E MUTAGENICIDADE DO BIODENTINE / EVALUATION OF GENOTOXICITY AND MUTAGENICITY OF BIODENTINE

Logar, Gustavo de Almeida 23 May 2014 (has links)
Made available in DSpace on 2016-01-26T18:55:40Z (GMT). No. of bitstreams: 1 Gustavo Logar.pdf: 371330 bytes, checksum: 461b03ba76909955dcf6db3c8b004b60 (MD5) Previous issue date: 2014-05-23 / The Biodentine is a new material suitable for various clinical situations in dentistry. Despite being a promising material, there are few studies evaluating the characteristics of this material, especially its genotoxicity and mutagenicity. Objective: This study aims to evaluate the genotoxic and mutagenic potential of Biodentine "in vivo". Methods: We used 24 Wistar albino rats, males were divided into 3 groups: A - 8 rats where specimens of Biodentine measuring 2 mm in diameter x 10mm length on the dorsum were placed, B - 8 rats, which received cyclophosphamide in single subcutaneous dose (50mg/kg) on the first day of the experiment (positive control group), C - 8 rats where specimens measuring 2 mm in diameter x 10mm long without Biodentine on the dorsum were placed (negative control group). After 24 hours, all animals were euthanized and material from bone marrow of femurs was collected to perform the Comet assay and micronucleus test. Results: Biodentine showed levels of DNA damage (tail intensity %) in bone marrow cells of 23.57 ± 7.70, cyclophosphamide of 27,43 ± 7,40 and negative control of 24.75 ± 5 55 (p < 0.05). The average number of micronuclei in the exposed Biodentine group was 6.25 (standard deviation - SD = 3.53), in the group exposed to cyclophosphamide was 9.75 (SD = 2.49) and negative control group was 0.75 (SD = 1.03) (p < 0.0001). Conclusion: The Biodentine showed an increase in the frequency of micronuclei, but no genotoxicity effect by the Comet assay. / O Biodentine é um novo material indicado para diversas situações clínicas na odontologia. Apesar de ser um material promissor, ainda há poucos trabalhos avaliando as características deste material, em especial sua genotoxicidade e mutagenicidade. Objetivo: Este estudo visa avaliar o potencial genotóxico e mutagênico do Biodentine in vivo . Material e métodos: Foram utilizados 24 ratos Wistar albinos, machos, distribuídos em 3 grupos: A 8 ratos onde foram colocados corpos de prova medindo 2mm de diâmetro x 10mm de comprimento com Biodentine no subcutâneo do dorso; B 8 ratos, que receberam ciclofosfamida em dose única subcutânea (50mg/kg) no primeiro dia do experimento (grupo controle positivo); C 8 ratos onde foram colocados corpos de prova medindo 2mm de diâmetro x 10mm de comprimento sem Biodentine no subcutâneo do dorso (grupo controle negativo). Após 24 horas, todos os animais foram eutanasiados e material da medula óssea dos fêmures foi coletado para realização do Teste do Cometa e do Teste do micronúcleo. Resultados: O Biodentine apresentou níveis de danos no DNA (tail intensity %) em células da medula óssea de 23,57 ± 7,70, a ciclofosfamida de 27,43 ± 7,40 e o controle negativo de 24,75 ± 5,55 (p<0,05). A média de micronúcleos no grupo exposto ao Biodentine foi de 6,25 (desvio padrão DP= 3,53), no grupo exposto a ciclofosfamida foi de 9,75 (DP= 2,49) e no grupo de controle negativo foi 0,75 (DP= 1,03) (p<0,0001). Conclusão: O Biodentine apresentou aumento na frequência de micronúcleos, mas não apresentou efeito genotóxico observado pelo teste do Cometa.
17

AVALIAÇÃO DA GENOTOXICIDADE E MUTAGENICIDADE DO BIODENTINE / EVALUATION OF GENOTOXICITY AND MUTAGENICITY OF BIODENTINE

Logar, Gustavo de Almeida 23 May 2014 (has links)
Made available in DSpace on 2016-07-18T17:53:13Z (GMT). No. of bitstreams: 1 Gustavo Logar.pdf: 371330 bytes, checksum: 461b03ba76909955dcf6db3c8b004b60 (MD5) Previous issue date: 2014-05-23 / The Biodentine is a new material suitable for various clinical situations in dentistry. Despite being a promising material, there are few studies evaluating the characteristics of this material, especially its genotoxicity and mutagenicity. Objective: This study aims to evaluate the genotoxic and mutagenic potential of Biodentine "in vivo". Methods: We used 24 Wistar albino rats, males were divided into 3 groups: A - 8 rats where specimens of Biodentine measuring 2 mm in diameter x 10mm length on the dorsum were placed, B - 8 rats, which received cyclophosphamide in single subcutaneous dose (50mg/kg) on the first day of the experiment (positive control group), C - 8 rats where specimens measuring 2 mm in diameter x 10mm long without Biodentine on the dorsum were placed (negative control group). After 24 hours, all animals were euthanized and material from bone marrow of femurs was collected to perform the Comet assay and micronucleus test. Results: Biodentine showed levels of DNA damage (tail intensity %) in bone marrow cells of 23.57 ± 7.70, cyclophosphamide of 27,43 ± 7,40 and negative control of 24.75 ± 5 55 (p < 0.05). The average number of micronuclei in the exposed Biodentine group was 6.25 (standard deviation - SD = 3.53), in the group exposed to cyclophosphamide was 9.75 (SD = 2.49) and negative control group was 0.75 (SD = 1.03) (p < 0.0001). Conclusion: The Biodentine showed an increase in the frequency of micronuclei, but no genotoxicity effect by the Comet assay. / O Biodentine é um novo material indicado para diversas situações clínicas na odontologia. Apesar de ser um material promissor, ainda há poucos trabalhos avaliando as características deste material, em especial sua genotoxicidade e mutagenicidade. Objetivo: Este estudo visa avaliar o potencial genotóxico e mutagênico do Biodentine in vivo . Material e métodos: Foram utilizados 24 ratos Wistar albinos, machos, distribuídos em 3 grupos: A 8 ratos onde foram colocados corpos de prova medindo 2mm de diâmetro x 10mm de comprimento com Biodentine no subcutâneo do dorso; B 8 ratos, que receberam ciclofosfamida em dose única subcutânea (50mg/kg) no primeiro dia do experimento (grupo controle positivo); C 8 ratos onde foram colocados corpos de prova medindo 2mm de diâmetro x 10mm de comprimento sem Biodentine no subcutâneo do dorso (grupo controle negativo). Após 24 horas, todos os animais foram eutanasiados e material da medula óssea dos fêmures foi coletado para realização do Teste do Cometa e do Teste do micronúcleo. Resultados: O Biodentine apresentou níveis de danos no DNA (tail intensity %) em células da medula óssea de 23,57 ± 7,70, a ciclofosfamida de 27,43 ± 7,40 e o controle negativo de 24,75 ± 5,55 (p<0,05). A média de micronúcleos no grupo exposto ao Biodentine foi de 6,25 (desvio padrão DP= 3,53), no grupo exposto a ciclofosfamida foi de 9,75 (DP= 2,49) e no grupo de controle negativo foi 0,75 (DP= 1,03) (p<0,0001). Conclusão: O Biodentine apresentou aumento na frequência de micronúcleos, mas não apresentou efeito genotóxico observado pelo teste do Cometa.
18

THE INFLUENCE OF PORE SYSTEM CHARACTERISTICS ON ABSORPTION AND FREEZE-THAW RESISTANCE OF CARBONATED, LOW-LIME CALCIUM SILICATE CEMENT (CSC) BASED MATERIALS

HyunGu Jeong (8816915) 08 May 2020 (has links)
This dissertation presents the study of freeze-thaw resistance of carbonated, low-lime calcium silicate cement based paste, mortar, and concrete and the pore system of these materials characterized by MIP, SEM, and image J analysis.
19

Resposta dos tecidos periodontais aos cimentos de silicato tricálcico associado ao óxido de zircônio ou óxido de nióbio usados no selamento de perfurações de furca em molares de ratos /

Barbosa, Derik Damasceno. January 2016 (has links)
Orientador: Paulo Sérgio Cerri / Banca: Lea Assed Bezerra da Silva / Banca: Mario Tanomaru Filho / Resumo: Perfurações radiculares acidentais ocorrem em cerca de 2-12% dos dentes tratados endodonticamente. Estas perfurações causam injúria aos tecidos periodontais adjacentes e, frequentemente, promovem a invasão bacteriana culminando com a inflamação do ligamento periodontal e reabsorção óssea podendo levar a perda do elemento dental. Dentre os materiais indicados para o selamento destas perfurações, o MTA tem sido largamente usado. O MTA é basicamente composto por silicatos de cálcio (80%) e óxido de bismuto (Bi2O3; 20%), usado como agente radiopacificador. Silicato tricálcico (STC) é um biomaterial utilizado associado ao óxido de zircônio (ZrO2) e o óxido de nióbio (Nb2O5) é um radiopacificador alternativo. O objetivo deste estudo foi avaliar a resposta dos tecidos periodontais promovida pelo silicato tricálcico puro (Mineral Research Processing, Meyzieu, França) associado ao ZrO2 ou ao Nb2O5 comparando-os ao MTA-Angelus, em perfuração de furca de molares de ratos. Foram utilizados 80 ratos, distribuídos em 4 grupos: GS (sham), STC+ZrO2, STC+Nb2O5 e GMTA, de acordo com o material de selamento. No grupo GS, as perfurações no assoalho da câmara pulpar não foram seladas. O acesso da cavidade foi restaurado com cimento de ionômero de vidro fotopolimerizável. Os 1os molares esquerdos, sem perfurações no assoalho da câmara pulpar, foram usados como controle (GC). Após os períodos de 7, 15, 30 e 60 as maxilas foram removidas, fixadas, descalcificadas e incluídas em parafina. Os cortes c... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Accidental radicular perforation occurs in about 2-12% of endodontically treated teeth. These perforations lead to injury of periodontal tissues and frequently promote bacterial invasion inducing to periodontal ligament inflammation and bone resorption may lead to tooth loss. Among the materials suitable for the sealing of these perforations, the MTA has been widely used. MTA is basically composed of calcium silicate (80%) and bismuth oxide (Bi2O3, 20%), a radiopacifying agent. Tricalcium silicate (TCS) is a biomaterial used associated with zirconium oxide (ZrO2) and niobium oxide (Nb2O5) is an alternative radiopacifier. Our purpose was to evaluate response of the periodontium adjacent to furcation perforations in rat molars filled with pure tricalcium silicate (Mineral Research Processing, Meyzieu, France) associated with ZrO2 or Nb2O5 and MTA-Angelus. Eighty rats were distributed into four groups: SG (sham), TCS+ZrO2, TCS+Nb2O5 and MTAG according to the sealing material. In the SG group, the perforations in the pulp chamber floors were not sealed. The access cavity was restored with light-cure glass-ionomer cement. The left upper first molars, without perforations in the pulp chamber floors, were used as controls (CG). After 7, 15, 30 and 60 days, fragments of maxilla were fixed, decalcified and embedded in paraffin. In the HE-stained sections, the volume density of inflammatory cells (VvIC), fibroblasts (VvFb) and blood vessels (VvBV) was obtained. The width of the periodo... (Complete abstract click electronic access below) / Mestre
20

Cimento de silicato de cálcio modificado com nanopartículas de vidro bioativo para aplicação como substituto de dentina /

Corral Núñez, Camila María. January 2017 (has links)
Orientador: Hernane da Silva Barud / Resumo: Os cimentos de silicato de cálcio têm se desenvolvido rapidamente durante as últimas décadas; com a aparição de novos cimentos para uso em odontologia restauradora. Estes cimentos apresentam diferentes composições químicas e por tanto provavelmente diferente radiopacidade. A incorporação de nanopartículas de vidro bioativo poderia melhorar a bioatividade dos cimentos de silicato de cálcio. O objetivo foi avaliar a composição química e radiopacidade dos cimentos a base de silicato de cálcio Biodentine (BD) e TheraCal LC e a contribuição do acréscimo de nanopartículas de vidro bioativo (nVB) no BD. Método: Foram realizados testes de radiopacidade de acordo com norma ISO 9917 e caracterização com microscopia eletrônica de varredura e análise elementar (MEV/EDX) dos novos cimentos de silicato de cálcio BD e TheraCal LC. Posteriormente, nVB foram sintetizadas com técnica sol-gel, e foram preparados nanocompósitos do BD com 1 e 2% em peso de nVB (1%nVB/BD e 2%nVB/BD). A bioatividade dos nanocompósitos foi avaliada in vitro e caracterizado com MEV/EDX, análise de espectroscopia no infravermelho por transformada de Fourier e difração de raios-X (DRX). Também os nanocompósitos foram aplicados em discos de dentina e a interface caracterizada com MEV-EDX. Resultados: BD apresentou zircônio como elemento radiopacificante e maiores valores de radiopacidade do que o TheraCal LC, que apresentou bário, estrôncio e zircônio como radiopacificadores. A incorporação de nVBs em BD melhorou a bioa... (Resumo completo, clicar acesso eletrônico abaixo) / Doutor

Page generated in 1.1514 seconds