• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 187
  • 4
  • 3
  • 1
  • Tagged with
  • 195
  • 195
  • 126
  • 103
  • 101
  • 82
  • 49
  • 48
  • 38
  • 38
  • 35
  • 34
  • 33
  • 31
  • 30
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
161

Distorções harmônicas produzidas por inversores de geração distribuída fotovoltaica em condição de ressonância paralela / Harmonic distortion produced by inverters photovoltaic distributed generation in parallel resonance condition

Fortes, Rárison Roberto Acácio [UNESP] 12 March 2016 (has links)
Submitted by RARISON ROBERTO ACACIO FORTES null (rarisonfortes@yahool.com) on 2016-05-05T14:43:06Z No. of bitstreams: 1 RFortes.pdf: 3576878 bytes, checksum: 1f31f85eeeb5bf64f3b8b9781d51941c (MD5) / Approved for entry into archive by Felipe Augusto Arakaki (arakaki@reitoria.unesp.br) on 2016-05-09T13:45:49Z (GMT) No. of bitstreams: 1 fortes_rra_me_ilha.pdf: 3576878 bytes, checksum: 1f31f85eeeb5bf64f3b8b9781d51941c (MD5) / Made available in DSpace on 2016-05-09T13:45:49Z (GMT). No. of bitstreams: 1 fortes_rra_me_ilha.pdf: 3576878 bytes, checksum: 1f31f85eeeb5bf64f3b8b9781d51941c (MD5) Previous issue date: 2016-03-12 / Fundação de Amparo à Pesquisa do Estado do Acre (FAPAC) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Como os sistemas de energia têm sido tradicionalmente projetados para produção centralizada, a penetração de sistemas de geração distribuída na rede tem causado mudança nesse perfil, criando novos desafios operacionais que se fazem importantes para a reestruturação dos sistemas tradicionais. No entanto, este novo cenário do sistema elétrico, introduzido pela resolução 482/2012 da Agência Nacional de Energia Elétrica – ANEEL, trouxe às distribuidoras de energia um novo panorama para as atividades de operação e manutenção de suas redes e ativos, principalmente devido à bidirecionalidade do fluxo de potência na rede, originado pela conexão de sistemas de geração distribuída. Os impactos técnicos devem ser previstos e analisados, sobretudo em redes de distribuição, para garantir os padrões mínimos de qualidade da energia no ponto de consumo e evitar o comprometimento das cargas alimentadas. Dentre os impactos, destaca-se o efeito sobre os bancos de capacitores devido à injeção de distorções harmônica produzida pelos inversores de sistemas fotovoltaicos, que sob certas condições, produzem conteúdo harmônico com nível acima do limite normatizado, podendo excitar uma condição prévia de ressonância no barramento. Neste contexto, esta dissertação tem como principal objetivo analisar o comportamento do sistema elétrico em condição de ressonância paralela e avaliar o grau de comprometimento dos bancos de capacitores instalados no sistema de distribuição com presença de frequências harmônicas e sugerir rotinas técnicas para evitar sua operação contingenciada. / As energy systems have been traditionally projected for centralized production, the penetration of distributed generation systems have caused a change in this profile, creating new operational challenges that are important for traditional systems restructuring. However, this new electrical system scenario, introduced by resolution 482/2012 of Brazilian Electricity Regulatory Agency – ANEEL, brought to energy distributors a new view to the operational and maintenance activities of their nets and actives, specially due to the net power flow bidirectionality, created by the distributed generation systems connection. Technical impacts must be estimated and analyzed, specially in distribution nets, to ensure minimum energy quality standards in the consumption point and avoid fed charges commitment. Among the impacts stands out the capacitor bench effects due to harmonic distortions injection produced by photovoltaic systems inverters, that under some conditions, produce harmonic content over the regulated limit, being able to excite a preview condition of resonance in the bus. In this context, this essay has the main objective to analyze the electrical system behavior in parallel resonance condition and evaluate the degree of commitment of the capacitor bench installed in the distribution system with harmonic frequencies and suggest technical routines to avoid the contingent operation. / FAPAC: 6068-14-0000093
162

Desenvolvimento de um inversor fotovoltaico trifásico não isolado conectado à rede elétrica / Development of a grid-connected transformerless three-phase photovoltaic inverter

Giacomini, Julian Cezar 09 March 2015 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / This Master Thesis presents the development of a grid-connected transformerless three-phase photovoltaic inverter. The Neutral Point Clamped (NPC) three-level inverter was chosen for implementation. The grid connection is made with a modified LCL filter (MLCL), where the common point of the output filter capacitors is connected directly to the dc bus central point (neutral point). The MLCL filter reduces the leakage current of photovoltaic system and attenuates the current harmonics injected in the grid. A passive damping of MLCL filter resonance peak was employed in order to avoid instability in the grid connection. In this sense, this Master Thesis contributes proposing a passive damping design method which is based not only on the stability requirement, but also considers the leakage current of photovoltaic system, once that passive damping impacts on the high frequency components of voltage on parasitic capacitance. Therefore, based on leakage current limit and current loop stability, a range for the damping resistance was obtained. The control system of the threephase inverter was developed in a synchronous reference frame (dq0), where the proper alignment with the grid voltage reference vector allows the independent control of active and reactive power inject in the grid. Simulation and experimental results are shown to evaluate the inverter performance and to validate the theoretical analysis. / Esta Dissertação de Mestrado apresenta o desenvolvimento de um inversor fotovoltaico trifásico não isolado conectado à rede. A topologia desenvolvida foi a de um inversor trifásico três níveis com ponto neutro grampeado (NPC Neutral Point Clamped). A conexão com a rede é feita através de um filtro LCL modificado (LCLM), que possui o ponto comum dos seus capacitores conectado ao ponto central do barramento CC do inversor. O filtro LCLM possui a finalidade de reduzir a corrente de fuga do sistema fotovoltaico ao mesmo tempo em que atenua os harmônicos de corrente injetados na rede. De modo a evitar problemas de instabilidade da malha de corrente do inversor, um sistema de amortecimento passivo do pico de ressonância do filtro LCLM foi empregado. Neste sentido, esta Dissertação de Mestrado contribui propondo um método de projeto do amortecimento passivo que se baseia não somente no critério de estabilidade, mas que também considera a corrente de fuga do sistema fotovoltaico, uma vez que o amortecimento impacta na atenuação das componentes de alta frequência da tensão sobre a capacitância parasita dos módulos fotovoltaicos. Com isso, uma faixa de valores para a resistência de amortecimento foi obtida a partir do limite permitido para a corrente de fuga e da estabilidade da malha de corrente. O sistema de controle do inversor trifásico foi desenvolvido com base no sistema de coordenadas síncronas dq0, cujo correto alinhamento com o vetor de referência das tensões da rede permite o controle independente das potências ativa e reativa injetadas na rede. Resultados experimentais e de simulação são apresentados de modo a comprovar o desempenho do inversor trifásico.
163

Estudo de características elétricas e térmicas de inversores para sistemas fotovoltaicos conectados à rede

Rampinelli, Giuliano Arns January 2010 (has links)
Os sistemas fotovoltaicos conectados à rede convertem diretamente a energia solar em energia elétrica entregando à rede elétrica de distribuição uma energia limpa e renovável. Esses sistemas são formados basicamente por um conjunto de módulos fotovoltaicos e inversores que são responsáveis por converterem energia elétrica em corrente contínua em energia elétrica em corrente alternada. Esta Tese apresenta um estudo de características elétricas e térmicas de inversores utilizados em sistemas conectados à rede a partir de uma análise teórica e experimental. Os ensaios de inversores foram realizados em duas etapas: a primeira etapa foi desenvolvida no Laboratório de Energia Solar (Labsol) da Universidade Federal do Rio Grande do Sul (UFRGS) onde foi utilizado um sistema fotovoltaico de 4,8 kWP e dez modelos de inversores de diferentes fabricantes. As características elétricas de inversores que foram medidas e analisadas são: eficiência de conversão de corrente contínua em corrente alternada, eficiência do seguidor do ponto de máxima potência, fator de potência e distorção harmônica na corrente e na tensão. Ensaios térmicos de inversores também foram realizados e os resultados apresentados e analisados. A segunda etapa dos ensaios foi desenvolvida no Laboratório de Energia Solar Fotovoltaica do Centro de Investigaciones Energéticas, Medioambientales y Tecnológicas (CIEMAT) na Espanha onde foi utilizado um sistema fotovoltaico de 3 kWP e sete modelos de inversores de diferentes fabricantes. Os inversores ensaiados são monofásicos de potência até 5 kW e de diferentes topologias (transformador de alta freqüência, baixa freqüência e sem transformador). A influência da tensão CC de entrada no comportamento da eficiência CC/CA e do fator de potência foi analisada. Os resultados obtidos nos ensaios permitiram o desenvolvimento de modelos matemáticos que descrevem o comportamento elétrico e térmico de inversores. Os modelos matemáticos propostos foram inseridos em um programa de simulação computacional desenvolvido no Labsol da UFRGS, denominado FVConect. A evolução dos resultados da simulação comparada valida plenamente os modelos utilizados. A análise dos resultados do comportamento de inversores amplia o conhecimento sobre o funcionamento desses equipamentos e a sua interação dinâmica com os demais componentes de sistemas fotovoltaicos conectados à rede. / Grid-connected photovoltaic systems directly convert solar energy into electrical energy delivering to the distribution grid a clean and renewable energy. These systems are basically formed by an array of photovoltaic modules and inverters. The inverters are responsible for converting direct current to alternating current. This Thesis presents a study of electrical and thermal characteristics of inverters used in grid-connected photovoltaic systems from a theoretical and experimental analysis. The inverters tests were carried out in two stages: the first stage was performed at Solar Energy Laboratory at Federal University of Rio Grande do Sul where it was used a 4,8 KWP grid-connected photovoltaic system and ten inverters of different manufacturers. The proposed mathematical models were inserted into computer simulation software developed at UFRGS named FVConect. The evolution of the simulation results compared to the experimental results validates the proposed models. The analysis of the behavior of the inverters improves the understanding of the operating of such equipment and their dynamic interaction with other grid-connected photovoltaic system components.
164

Energia solar fotovoltaica conectada à rede de energia elétrica em Cuiabá : estudo de caso

Apolônio, Daniel Moussalem 25 August 2014 (has links)
Submitted by Simone Souza (simonecgsouza@hotmail.com) on 2017-10-06T15:12:15Z No. of bitstreams: 1 DISS_2014_Daniel Moussalem Apolonio.pdf: 7540330 bytes, checksum: 1d1c94a7cce19da52ea4511636e5f609 (MD5) / Approved for entry into archive by Jordan (jordanbiblio@gmail.com) on 2017-11-06T13:59:30Z (GMT) No. of bitstreams: 1 DISS_2014_Daniel Moussalem Apolonio.pdf: 7540330 bytes, checksum: 1d1c94a7cce19da52ea4511636e5f609 (MD5) / Made available in DSpace on 2017-11-06T13:59:30Z (GMT). No. of bitstreams: 1 DISS_2014_Daniel Moussalem Apolonio.pdf: 7540330 bytes, checksum: 1d1c94a7cce19da52ea4511636e5f609 (MD5) Previous issue date: 2014-08-25 / A crescente utilização da energia solar fotovoltaica decorrente do aumento da competitividade econômica na instalação de sistemas fotovoltaicos conectados à rede (SFCR) demanda estudos de aplicabilidade e inovações tecnológicas e de processos nessa área do conhecimento. A evolução da aplicação de geração solar dos países pioneiros demonstra a grande possibilidade de investimentos no setor em um futuro próximo, principalmente após a possibilidade de conexão à rede e de geração distribuída regularizada e normatizada pela ANEEL no Brasil. O objetivo deste trabalho é o estudo de sistemas solares fotovoltaicos conectados à rede no que tange ao seu dimensionamento, funcionamento, operação, qualidade da energia gerada, eficiência energética do sistema e quantidade de energia gerada, obtida por medição e simulação, através de um estudo de caso de um sistema instalado na Universidade Federal de Mato Grosso (UFMT), campus Cuiabá. O sistema de 510 Wp gerou 583,66 kWh de energia elétrica durante um ano de medição e apresentou performance ratio de 0,657 frente aos 0,731 definido como padrão pela NREL (2005). Algumas características técnicas do sistema foram averiguadas e comparadas com os valores de placa. Os resultados obtidos com o uso dos programas computacionais mostram-se apropriados na etapa de elaboração dos projetos, previsão de geração de energia e retorno financeiro dos sistemas a serem instalados. O retorno financeiro para o sistema instalado se dará em aproximadamente 20 anos e para sistemas de 3 kWp em que 100% da carga é utilizada na própria edificação com tarifa B a viabilidade financeira será alcançada em 2016. O retorno financeiro de investimentos em SFCR varia de acordo com o sistema a ser aplicado, e tende a ser suscetível a mudanças bruscas devido principalmente às legislações, incentivos tributários por parte do governo e variações no preço dos componentes dos sistemas e das tarifas de energia. / The increasing usage of solar photovoltaic systems because of the growth of economic competitiveness demands studies in applications and technological or process innovations in this field of knowledge. The evolution of the application of solar generation by the pioneers countries demonstrate the possibility of large investments in the sector in a near future, especially after the possibility of grid connection and distributed generation regulated by ANEEL in Brazil. The objective of this work is to study on-grid solar photovoltaic systems regarding its project, operation, power quality, system efficiency and the amount of energy generated, obtained by simulations and measurements, through a case study of an installed system working at the Federal University of Mato Grosso (UFMT), Cuiabá campus. The 510 Wp system generated 583,66 kWh of electric energy during a year of measurements and presented performance ratio of 0,657 in comparison to the 0,731 standard for PV systems of NREL (2005). Some system technical characteristics were checked and compared with nominal values on the manual. The results obtained by the softwares are appropriated as an assistant for projecting, energy generation prediction e financial feasibility for the incoming systems. The payback for the installed system is predicted to approximately 20 years and for 3 kWp systems in which the generation is used in the building before injected with B energy fee the viability is going to be reached in 2016. The payback of the investment on on-grid photovoltaic systems vary from each system, and tend to be susceptible to harsh variations, mainly due to legislations and government support and changes in the photovoltaics equipment prices and the electric energy rates.
165

Distorções harmônicas produzidas por inversores de geração distribuída fotovoltaica em condição de ressonância paralela /

Fortes, Rárison Roberto Acácio January 2016 (has links)
Orientador: Luís Carlos Origa de Oliveira / Resumo: Como os sistemas de energia têm sido tradicionalmente projetados para produção centralizada, a penetração de sistemas de geração distribuída na rede tem causado mudança nesse perfil, criando novos desafios operacionais que se fazem importantes para a reestruturação dos sistemas tradicionais. No entanto, este novo cenário do sistema elétrico, introduzido pela resolução 482/2012 da Agência Nacional de Energia Elétrica – ANEEL, trouxe às distribuidoras de energia um novo panorama para as atividades de operação e manutenção de suas redes e ativos, principalmente devido à bidirecionalidade do fluxo de potência na rede, originado pela conexão de sistemas de geração distribuída. Os impactos técnicos devem ser previstos e analisados, sobretudo em redes de distribuição, para garantir os padrões mínimos de qualidade da energia no ponto de consumo e evitar o comprometimento das cargas alimentadas. Dentre os impactos, destaca-se o efeito sobre os bancos de capacitores devido à injeção de distorções harmônica produzida pelos inversores de sistemas fotovoltaicos, que sob certas condições, produzem conteúdo harmônico com nível acima do limite normatizado, podendo excitar uma condição prévia de ressonância no barramento. Neste contexto, esta dissertação tem como principal objetivo analisar o comportamento do sistema elétrico em condição de ressonância paralela e avaliar o grau de comprometimento dos bancos de capacitores instalados no sistema de distribuição com presença de frequências harmô... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: As energy systems have been traditionally projected for centralized production, the penetration of distributed generation systems have caused a change in this profile, creating new operational challenges that are important for traditional systems restructuring. However, this new electrical system scenario, introduced by resolution 482/2012 of Brazilian Electricity Regulatory Agency – ANEEL, brought to energy distributors a new view to the operational and maintenance activities of their nets and actives, specially due to the net power flow bidirectionality, created by the distributed generation systems connection. Technical impacts must be estimated and analyzed, specially in distribution nets, to ensure minimum energy quality standards in the consumption point and avoid fed charges commitment. Among the impacts stands out the capacitor bench effects due to harmonic distortions injection produced by photovoltaic systems inverters, that under some conditions, produce harmonic content over the regulated limit, being able to excite a preview condition of resonance in the bus. In this context, this essay has the main objective to analyze the electrical system behavior in parallel resonance condition and evaluate the degree of commitment of the capacitor bench installed in the distribution system with harmonic frequencies and suggest technical routines to avoid the contingent operation. / Mestre
166

An?lise de impactos na rede de distribui??o de energia el?trica decorrentes da inser??o de sistemas de gera??o fotovoltaicos

Nunes, Evandro Ailson de Freitas 30 June 2017 (has links)
Submitted by Automa??o e Estat?stica (sst@bczm.ufrn.br) on 2017-10-02T23:37:04Z No. of bitstreams: 1 EvandroAilsonDeFreitasNunes_DISSERT.pdf: 2832434 bytes, checksum: fbd09520d8dfca43784e60b088545e00 (MD5) / Approved for entry into archive by Arlan Eloi Leite Silva (eloihistoriador@yahoo.com.br) on 2017-10-07T00:23:58Z (GMT) No. of bitstreams: 1 EvandroAilsonDeFreitasNunes_DISSERT.pdf: 2832434 bytes, checksum: fbd09520d8dfca43784e60b088545e00 (MD5) / Made available in DSpace on 2017-10-07T00:23:58Z (GMT). No. of bitstreams: 1 EvandroAilsonDeFreitasNunes_DISSERT.pdf: 2832434 bytes, checksum: fbd09520d8dfca43784e60b088545e00 (MD5) Previous issue date: 2017-06-30 / Coordena??o de Aperfei?oamento de Pessoal de N?vel Superior (CAPES) / Atualmente, os incentivos ? gera??o de energia el?trica a partir da fontes consideradas limpas v?m aumentando consideravelmente devido ? escassez dos combust?veis f?sseis, at? ent?o utilizados em abund?ncia. Em paralelo, unidades de gera??o distribu?da que utilizam fontes renov?veis tamb?m ganha for?a com a diminui??o dos impostos aplicados sobre os componentes constituintes dos sistemas de gera??o que utilizam este tipo de fonte de energia. No entanto, a qualidade da energia el?trica tem sido severamente afetada pelo aumento do n?mero desses sistemas ligados ?s redes de distribui??o de baixa tens?o. Com base nisso, nesta disserta??o s?o avaliados os impactos na rede de distribui??o de energia el?trica decorrentes da conex?o de instala??es fotovoltaicas, em v?rios n?veis de penetra??o. Nesse intuito, ? realizado um estudo de caso que consiste em operar uma planta fotovoltaica de 9 kWp conectada ao ponto de acoplamento comum de uma subesta??o com pot?ncia nominal de 15 kVA. O sistema fotovoltaico utilizado, se divide em: i) sistema trif?sico fixo de 8 kWp e ii) sistema monof?sico fixo de 1 kWp. A avalia??o ? feita com base nos indicadores da qualidade da energia el?trica, que indicam as caracter?sticas de pot?ncia, harm?nicos de tens?o e corrente, desequil?brios entre fases do sistema e regula??o do fator de pot?ncia. A partir da an?lise desses indicadores, obtidos com aux?lio da transformada discreta de Fourier, ? realizada uma an?lise do impacto gerado pela planta fotovoltaica no ponto de conex?o com a rede el?trica. Por meio de resultados experimentais, os indicadores s?o estimados durante a opera??o do sistema fotovoltaico e s?o analisados e comparados com o padr?o internacional estabelecido pelo IEEE (do ingl?s, Institute of Electrical and Electronics Engineers). / Currently, incentives for clean energy generation have been increasing considerably due to the limitation of fossil fuels, until then used in abundance. In parallel, distributed generations increase with the reduction of the taxes of the embedded components of the renewable energy sources. However, the power quality (PQ) has been severely affected by the increasing number of these types of energy sources connected to low voltage distribution networks. In this dissertation, the impact on the utility grid will be evaluated under varying levels of a photovoltaic system penetration. A 9 kWp photovoltaic plant, composed of three system topologies connected to a 15 kVA substation common coupling point, will be carried out: a 8 kWp three-phase fixed topology and a 1 kWp fixed single phase. These photovoltaic systems are power electronics based devices, such as inverters constructed from semiconductor switches, which, due to their construction and operation, affect the waveform of the electrical voltage and current, deteriorating the PQ. From the analysis of PQ indices, obtained by means of discrete Fourier transform, for power characteristics, voltage and current harmonics, imbalanced levels among system phases and power factor regulation, an analysis of the impact generated by the photovoltaic plant at its point of connection with the utility grid will be performed. The indices will be analyzed and compared to the standards established by the Institute of Electrical and Electronics Engineers (IEEE) in order to evaluate the impact caused by the connection of the photovoltaic system at the PCC.
167

Inversor flyback a quatro transistores controlado por um dispositivo FPGA para obter MPPT em sistemas fotovoltaicos

Marques, Fernando Nunes 04 November 2008 (has links)
Conselho Nacional de Desenvolvimento Científico e Tecnológico / Electrical energy generation with photovoltaic cells is being more utilized. Not only on large scale systems, but also in small ones connected to the grid. Parallel operating with the great generators from power companies, in a non-centralized way of operation, supplying low power, installed in houses, commerce establishments, industry, with the goal to minimize the loss in transmission, for being installed at the same consumption place. This work presents a FPGA device controller of a four transistor flyback inverter for maximum power point in photovoltaic systems. Despite this system has low power it contributes to search simple and low cost alternatives for generating of electrical power in a decentralized manner, which does not use battery banks connected parallel to network of energy near to consumers. / Geração de energia elétrica a partir de painéis fotovoltaicos vem sendo cada vez mais utilizada, não somente em sistemas fotovoltaicos de grande porte, como também em pequenos sistemas conectados a rede CA. Interligada paralelamente aos grandes geradores da concessionária de energia de forma descentralizada em sistemas de pequeno porte e baixas potências, instalados em residências, estabelecimentos comerciais, indústria, com o objetivo de minimizar perdas por transmissão por estarem instalados nos próprios locais. Este trabalho apresenta um controle num dispositivo FPGA de um inversor flyback a quatro transistores para máxima potência em sistemas fotovoltaicos. Apesar da baixa potência este contribui para a busca de alternativas simples e de baixo custo para geração de energia elétrica de forma descentralizada, não utilizando bancos de bateria conectados paralelamente a rede de energia próxima aos consumidores. / Mestre em Ciências
168

Degradação induzida pelo potencial em módulos e instalações fotovoltaicas de c-Si / Potential induced degradation on c-Si photovoltaic modules and installations

Gilberto Figueiredo Pinto Filho 14 November 2017 (has links)
Este trabalho apresenta abordagens para a avaliação do fenômeno da Degradação Induzida pelo Potencial (PID do inglês Potential Induced Degradation) em módulos e instalações fotovoltaicas de c-Si. Nos ensaios em laboratório, a IEC TS 62804-1:2015 foi aplicada e ações adicionais são sugeridas como forma de adaptação da especificação técnica para o acompanhamento da degradação durante o ensaio e para melhor indicar a propensão do equipamento a se recuperar das consequências da aparição de PID. Nos ensaios em campo, avaliou-se a solução convencional do mercado de reverter a degradação através de circuitos anti-PID, além de apresentar a aplicação de técnicas de detecção do fenômeno em sistemas operacionais. A abordagem teórica e os resultados práticos mostram que o procedimento de aferição de tensões individuais de operação é um método útil para detectar PID. Os estudos de caso apresentados indicam que esta metodologia é eficaz inclusive na detecção precoce do fenômeno para diferentes topologias de células fotovoltaicas de c-Si. / This work presents approaches to assess the Potential Induced Degradation (PID) on c-Si photovoltaic modules and installations. The IEC TS 62804-1:2015 was applied to the laboratory tests and some additional actions are suggested. The adaptation of the technical specification aims to monitor the degradation rates during the tests and also to consider the capacity of the photovoltaic modules to recover from the degradation. In the field detection methodologies are presented and anti-PID circuits were also tested. The theoretical approach reveals that individual voltage measurements are useful to detect PID even in its early stage, as can be seen on the case studies presented.
169

Estudo de características elétricas e térmicas de inversores para sistemas fotovoltaicos conectados à rede

Rampinelli, Giuliano Arns January 2010 (has links)
Os sistemas fotovoltaicos conectados à rede convertem diretamente a energia solar em energia elétrica entregando à rede elétrica de distribuição uma energia limpa e renovável. Esses sistemas são formados basicamente por um conjunto de módulos fotovoltaicos e inversores que são responsáveis por converterem energia elétrica em corrente contínua em energia elétrica em corrente alternada. Esta Tese apresenta um estudo de características elétricas e térmicas de inversores utilizados em sistemas conectados à rede a partir de uma análise teórica e experimental. Os ensaios de inversores foram realizados em duas etapas: a primeira etapa foi desenvolvida no Laboratório de Energia Solar (Labsol) da Universidade Federal do Rio Grande do Sul (UFRGS) onde foi utilizado um sistema fotovoltaico de 4,8 kWP e dez modelos de inversores de diferentes fabricantes. As características elétricas de inversores que foram medidas e analisadas são: eficiência de conversão de corrente contínua em corrente alternada, eficiência do seguidor do ponto de máxima potência, fator de potência e distorção harmônica na corrente e na tensão. Ensaios térmicos de inversores também foram realizados e os resultados apresentados e analisados. A segunda etapa dos ensaios foi desenvolvida no Laboratório de Energia Solar Fotovoltaica do Centro de Investigaciones Energéticas, Medioambientales y Tecnológicas (CIEMAT) na Espanha onde foi utilizado um sistema fotovoltaico de 3 kWP e sete modelos de inversores de diferentes fabricantes. Os inversores ensaiados são monofásicos de potência até 5 kW e de diferentes topologias (transformador de alta freqüência, baixa freqüência e sem transformador). A influência da tensão CC de entrada no comportamento da eficiência CC/CA e do fator de potência foi analisada. Os resultados obtidos nos ensaios permitiram o desenvolvimento de modelos matemáticos que descrevem o comportamento elétrico e térmico de inversores. Os modelos matemáticos propostos foram inseridos em um programa de simulação computacional desenvolvido no Labsol da UFRGS, denominado FVConect. A evolução dos resultados da simulação comparada valida plenamente os modelos utilizados. A análise dos resultados do comportamento de inversores amplia o conhecimento sobre o funcionamento desses equipamentos e a sua interação dinâmica com os demais componentes de sistemas fotovoltaicos conectados à rede. / Grid-connected photovoltaic systems directly convert solar energy into electrical energy delivering to the distribution grid a clean and renewable energy. These systems are basically formed by an array of photovoltaic modules and inverters. The inverters are responsible for converting direct current to alternating current. This Thesis presents a study of electrical and thermal characteristics of inverters used in grid-connected photovoltaic systems from a theoretical and experimental analysis. The inverters tests were carried out in two stages: the first stage was performed at Solar Energy Laboratory at Federal University of Rio Grande do Sul where it was used a 4,8 KWP grid-connected photovoltaic system and ten inverters of different manufacturers. The proposed mathematical models were inserted into computer simulation software developed at UFRGS named FVConect. The evolution of the simulation results compared to the experimental results validates the proposed models. The analysis of the behavior of the inverters improves the understanding of the operating of such equipment and their dynamic interaction with other grid-connected photovoltaic system components.
170

Otimização da forma para captação da radiação solar sobre superfícies de edifícios : um exercício de integração entre os programas Rhinoceros e Ecotect

Vannini, Virgínia Czarnobay January 2011 (has links)
Este trabalho tem como objetivo explorar a forma de planos de fachada vinculados à incidência solar, potencializando a aplicação de sistemas fotovoltaicos. A identificação e parametrização de formas segundo os princípios geométricos de captação fotovoltaica, sugerem a aplicação de uma metodologia de projeto para superfícies de fachadas fotovoltaicas, de modo a otimizar a incidência direta da radiação solar, incorporada a volumetria da edificação. O modelo de otimização de fachadas fotovoltaicas consiste em quatro etapas. Inicialmente define-se a tecnologia fotovoltaica e a localização geográfica (1). Posteriormente, é realizada a modelagem elementar tridimensional (2) através do editor de algoritmos gráficos Grasshopper – integrado à ferramenta de modelagem Rhinoceros3D – estabelecendo assim, as restrições e variáveis da forma. Na terceira etapa, correlacionamse transformações geométricas tridimensionais (twist, taper e shear) e incidência solar (3) por meio dos softwares Ecotect Analysis e Grasshopper. Com isso, os parâmetros dimensionais atribuídos às variáveis – transformações geométricas – são vinculados aos parâmetros de radiação solar, visando à geração de formas. Após a seleção das formas com maior potencial fotovoltaico, identificam-se as zonas com maior incidência de radiação solar e realiza-se a manipulação dos pontos de controle das superfícies NURBS (4). Através das transformações geométricas taper, shear e twist foi possível gerar um conjunto de soluções otimizadas, correlacionando dados energéticos e geométricos, integrando métodos de geração de formas e avaliação performática da radiação solar. O estudo identificou que as possibilidades de articulação entre os planos fotovoltaicos e a eficiência energética têm implicações positivas, correlacionando variabilidade formal e geração de energia elétrica. / This work aims explore the shape of façade planes linked to the solar incidence, in order to optimize the use of photovoltaic systems. The identification and parameterization of forms according to geometric principles of photovoltaic capture suggest the application of a design methodology for optimizing the photovoltaic surface façade in order to optimize direct solar radiation, incorporating the volume of the building. The optimization model of photovoltaic façade consists of four steps. Initially decide on the photovoltaic technology and geographic location (1). Subsequently, three-dimensional elementary modeling is performed (2) through the graphic-algorithm editor, Grasshopper, – integrated with the modeling tool, Rhinoceros 3D, – thus establishing, restrictions and variables in shape. In the third stage, threedimensional geometric transformations are correlated (twist, taper and shear) and solar incidence (3) through the computer interfaces of Ecotect Analysis and Grasshopper software. With this, the dimensional parameters assigned to the variables – geometric transformations – are linked to parameters of solar radiation, in order to generate shapes. After the selection of potential photovoltaic shapes, zones with the greatest incident solar radiation are identified and the control points of NURBS surface are manipulated (4). Using the geometric transformations taper, shear and twist, it was possible to generate a set of optimal solutions, correlating geometric and energetic data, integrating shape generating methods and performatic evaluation of solar exposure. The work identified that possibilities of articulation between photovoltaic planes and energetic efficiency have positive results, correlating shape variability and electricity generation.

Page generated in 0.0999 seconds