161 |
Bioindicadores para determinação de metais pesados no Reservatório da Itaipu Binacional, Paraná, Brasil / Bioindicators for the determination of heavy metals in the reservoir of Itaipu, Paraná, BrazilChambo, Ana Paula Sartório 26 August 2011 (has links)
Made available in DSpace on 2017-07-10T17:48:28Z (GMT). No. of bitstreams: 1
Ana_Paula_Sartorio_Chambo.PDF: 2055310 bytes, checksum: 572f35f1e55b0455d7858396549a5810 (MD5)
Previous issue date: 2011-08-26 / Fundação Araucária / This study was conducted in the reservoir of Itaipu Hydroelectric Plant, located in the western region of Paraná State, during the March/2010 to April/2009 and aimed to study the chemical composition (macronutrients, micronutrients and toxic heavy metals), the bioaccumulation of biologically essential metals, copper (Cu), iron (Fe), zinc (Zn) and manganese (Mn), and non-essential toxic heavy metals, cadmium (Cd), chromium (Cr) and lead (Pb) in tissues of the armado (P. granulosus), mollusks (L. fortunei) and aquatic plants (E. densa and E. crasssipes), beyond the study of water quality and sediment under modified atmospheres, such as reservoirs for multiple uses, during the season the year. Fifteen fish were collected monthly to determine the factor relative corporal condition (Kn), the index of viscera total (IVT), visceral fat index (IGV), the hepatosomatic index (HSI) and the metal pollution index (MPI), as well as samples the sediment, water and the biomarkers golden mussel and two species of aquatic macrophytes, E. crassipes and E. dense. It was observed that the carcass of the armado bioaccumulate in the following order Fe, Ca, Zn, Pb, Mn, K, Mg, Cr, Cu e Cd. The nitrogen was concentrated in greater proportion in the carcass (110.58 g kg-1) and fillet (109.96 g kg-1) and phosphorus in the liver (43.26 g kg-1). The Cd was present in 50% of carcass samples (1.20 mg kg-1) and skin (1.00 mg kg-1) and 100% of the samples of gills (1.00 mg kg-1). The Cr was detected in 33% of carcass samples (2.75 mg kg-1) and gills (1.00 mg kg-1) and 17% of fillet samples (2.00 mg kg-1). The presence of lead was found in 100% of samples with levels ranging from 20.17 mg kg-1 in the carcass and 7.83 mg kg-1 in the fillet. The distribution of Cu, Zn and Mn in the sediment and water did not change seasonally. The analytical method used did not detect the presence of Cu and Zn in the water sample. The physical and chemical variables of water were not oscillated along the year season. The index calculated for the E. densa responded significantly seasonal fluctuations, with the highest rates were obtained during the summer followed by spring, winter and autumn. The armado captured during the experiment were contaminated by heavy metals Cd, Cr and Pb at levels above those recommended by current legislation. The rate of metal contamination suggests that the liver is the organ most bioaccumulate heavy metals in the gun. The deposition of heavy metals in sediment and water did not change seasonally, the sampling of sediment, E. densa and root of E. crassipes may indicate the composition of environmental contamination / Este trabalho foi realizado no reservatório da Usina Hidrelétrica de Itaipu Binacional, localizada na região oeste do Estado do Paraná, durante o período de abril/2009 a março/2010 e teve como objetivo o estudo sobre a composição química (macronutrientes, micronutrientes e metais pesados tóxicos), a bioacumulação de metais pesados biologicamente essenciais, cobre (Cu), ferro (Fe), zinco (Zn) e manganês (Mn), e metais pesados tóxicos, cádmio (Cd), cromo (Cr) e chumbo (Pb), nos tecidos do armado (P. granulosus), moluscos (L. fortunei) e plantas aquáticas (E. densa e E. crasssipes), além do estudo da qualidade da água e dos sedimentos em ambientes modificados, como os reservatórios de usos múltiplos, durante as estações do ano. Foram coletados mensalmente quinze peixes para determinação do fator de condição corporal relativo, o índice de víscera total, o índice de gordura visceral, o índice hepatossomático e o índice de poluição por metais, bem como amostras de sedimento, água e dos bioindicadores mexilhão dourado e duas espécies de macrófitas aquáticas E. crassipes e E. densa. Observou-se que a carcaça do armado bioacumulou os elementos na seguinte ordem decrescente Fe, Ca, Zn, Pb, Mn, K, Mg, Cr, Cu e Cd. O nitrogênio concentrou-se em maior proporção na carcaça (110,58 g kg-1) e no filé (109,96 g kg-1) e o fósforo no fígado (43,26 g kg-1). O Cd esteve presente em 50% das amostras de carcaça (1,20 mg kg-1) e pele (1,00 mg kg-1) e em 100% das amostras de brânquias (1,00 mg kg-1). O Cr foi detectado em 33% das amostras de carcaça (2,75mg kg-1) e brânquias (1,00 mg kg-1) e em 17% das amostras de filé (2,00 mg kg-1). A presença de chumbo foi constatada em 100% das amostras com teores variando entre 20,17 mg kg-1 na carcaça e 7,83 mg kg-1 no filé. A distribuição dos metais Cu, Fe, Zn e Mn no sedimento e na água não sofreram efeito sazonal. O método analítico utilizado não detectou a presença de Cu e Zn na água do reservatório. As variáveis físicas e químicas da água não oscilaram ao longo do ano. O índice de metais pesados calculado para a E. densa respondeu significativamente as oscilações sazonais, sendo que os maiores valores obtidos durante o verão seguidos pela primavera, inverno e outono. Os armados capturados durante o período experimental estavam contaminados pelos metais pesados Cd, Cr e, Pb em níveis acima dos recomendados pela legislação vigente. O índice de contaminação por metais aponta que o fígado é o órgão que mais bioacumulou metais pesados no armado. As deposições de metais pesados no sedimento e na água não sofreram efeito sazonal. A amostragem dos sedimentos, E. densa e raiz da E. crassipes pode indicar a composição da contaminação do ambiente e a E. densa pode ser utilizado como bioindicador em áreas poluídas
|
162 |
Impacto do lançamento de lodo de tanques/fossas sépticas em estação de tratamento de esgoto com reator anaeróbio de fluxo ascendente e manta de lodo (UASB) / Impact of sludge disposal of septic tanks on wastewater treatment plant with upflow anaerobic sludge blanket (UASB)Camila do Prado Gonçalves 31 October 2008 (has links)
Neste trabalho avaliou-se o desempenho de um reator anaeróbio de fluxo ascendente e manta de lodo (UASB) no tratamento combinado de esgoto sanitário com o lançamento de lodo proveniente de tanques sépticos. O estudo foi desenvolvido em escala plena na Estação de Tratamento de Esgoto (ETE) do Campus I da Universidade de São Paulo (USP) em São Carlos-SP. Foram utilizados dois reatores UASB com 18,8 m³ cada, um reator (UASB I) com função de controle e o outro reator (UASB II) no qual foi descarregado o lodo séptico. A pesquisa foi dividida em duas etapas: a primeira compreendeu o início de operação e o monitoramento dos reatores e, da segunda fez parte os ensaios de lançamento de lodo séptico no sistema. A partida foi efetuada sem utilização de inóculo e os reatores foram operados com tempo de detenção hidráulica médio (TDH) de 8 h, vazão afluente média de 2,35 m³/h e velocidade ascensional de 0,6 m/h. Em seis meses de operação os reatores apresentaram eficiências médias de remoção de DQO nos reatores UASB I e UASB II iguais a 49% e 65%. Quanto à remoção de sólidos os reatores UASB I e UASB II atingiram remoção de 36% e 37% para ST e de 67% e 63% para SST, respectivamente. Após esse período, deu-se início ao estudo que avaliou o impacto do lançamento de lodo séptico no UASB II. Foram realizados três ensaios com diferentes volumes de lodo (1; 3 e 5 m³) descarregados na forma de pulso com vazão média de 5,24 m³/h. Os lodos sépticos utilizados na pesquisa foram coletados por caminhões limpa-fossa e descarregados em um reservatório (15 m³) na ETE para posterior lançamento no reator UASB II. Foram feitas as caracterizações das amostras dos lodos sépticos (coletadas no ato da descarga em cada ensaio), com as quais pôde-se constatar a heterogeneidade da composição desse tipo de resíduo e sua viabilidade de pós-tratamento anaeróbio. Nos ensaios foram realizados monitoramentos temporais logo após a descarga de lodo para acompanhamento da resposta ao pulso de carga imposto. No geral, o reator UASB apresentou capacidade de degradar aproximadamente 2/3 da carga orgânica lançada com o lodo séptico. Os resultados são um indicativo de que a disposição de lodo sépticos em reatores UASB, quando bem programada, é uma solução viável e de grande importância para o tratamento dos resíduos provenientes de tanques/fossas sépticas. / The performance of upflow anaerobic sludge blanket (UASB) in the sanitary wastewater combined treatment with sludge disposal of septic tanks was evaluated in this work. The study was carried out (full scale) in the Wastewater Treatment Plant (WTP) located in campus I of the University of Sao Paulo (USP), city of Sao Carlos, State of Sao Paulo, Brazil. Two UASB reactors were used; volume of each reactor ~ 18,8 m³. UASB I was the control reactor, and UASB II was the reactor in which the septic sludge was disposed. The research was divided in two steps: the first one, which has taken into account the beginning of reactors operation and, the second one, in which occurred the disposal of septic sludge in the reactors. The start-up was carried out without utilization of inoculums. Reactors were operated with an average hydraulic retention time of 8 hours, average influent flow rate of 2.35 m³/h, and upflow velocity of 0.6 m/h. In six months, reactors presented average removal efficiencies of COD in UASB I and UASB II of 48% and 65%, respectively. Concerning to the solid removal, UASB I and UASB II have achieved removal of 36% and 37% for TS, and 67% and 63% for TSS, respectively. After this period of time, the evaluation of disposal impact of septic sludge was started in UASB II. Three essays with different sludge volume (1, 3, and 5 m³) were carried out; sludge volume was disposed in a pulse way with average flow rate of 5.24 m³/h. Septic sludge utilized in the research was collected by clean septic tank trucks, and disposed in a reservoir (volume of 15 m³) in WTP, in order to allow further disposal in the UASB II. By the hand of characterization of septic sludge samples (collected when disposal was carried out), it was possible to verify the heterogeneity about composition of this kind of waste and its availability in terms of anaerobic post-treatment. Temporal monitoring after the sludge disposal was carried out in order to allow the accompaniment of results provided by the pulse. In general, UASB reactor presented capacity in terms of degradation of approximately 2/3 of the organic load disposed with septic sludge. The results are a good indicative that the disposal of septic sludge in UASB reactors is a viable solution, and it is very important for the treatment of wastes from septic tanks.
|
163 |
Estudo da influência da malha computacional, modelos de turbulência e aspectos numéricos da modelagem CFD em impelidores PBT usando malhas não-estruturadas / Investigation on the influence of computational mesh, turbulence models and numerical aspects of CFD modeling in PBT impellers using non-structured meshesVergel, José Luis Gomez, 1985- 22 August 2018 (has links)
Orientadores: José Roberto Nunhez, Nicolas Spogis / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Química / Made available in DSpace on 2018-08-22T07:47:05Z (GMT). No. of bitstreams: 1
Vergel_JoseLuisGomez_M.pdf: 8156840 bytes, checksum: f0b5d7b4b0875d4716285f8ec3ce5fa2 (MD5)
Previous issue date: 2013 / Resumo: O uso de malhas não estruturadas recentemente tem recebido uma considerável atenção para discretização do domínio computacional em simulações CFD (Vakili & Esfahany, 2009; Cabrales, et al., 2011). A malha não estruturada (comumente tetraédricas) permite uma adequada adaptação em geometrias irregulares e uma geração automática na maioria dos softwares comerciais em CFD. Na literatura constantemente tem sido sugerido que as malhas hexaédricas são preferidas as tetraédricas, porém esta última pode ser usada, desde que alguns cuidados sejam tomados para proporcionar uma boa representação do fenômeno físico do problema. Alguns trabalhos recentemente publicados mostram que as malhas tetraédricas quando utilizadas com cuidado, podem obter resultados satisfatórios (Spogis & Nunhez, 2009). A maioria dos trabalhos desenvolvidos com uso da simulação CFD para processos de mistura utilizam malha hexaédrica, enquanto os resultados obtidos com malhas tetraédricas não possuem a mesma aprovação (Joaquim Junior et al., 2007), parte deste trabalho esta focado em mostrar que elas podem fornecer bons resultados em simulações de processos de mistura. Outro objetivo desse trabalho é mostrar o efeito do refinamento em malhas tetraédricas. Investigou-se a influência dos elementos prismáticos perto da parede sobre parâmetros globais, tais como o número de potência e número de bombeamento. Foi também realizada uma análise inicial da sensibilidade de alguns modelos de turbulência e esquemas de discretização sobre o campo de fluxo produzido. Além disso, simulações com diferentes refinamentos de malha foram feitas usando a abordagem de múltiplos sistemas de referência (MFR); enquanto em outros casos foi proporcionada uma abordagem de malhas deslizantes (SG) no impelidor. Os esquemas de discretização foram limitados aos esquemas Upwind, High resolution e blend fator, uma vez que esquemas diferentes não funcionam adequadamente com elementos tetraédricos. O software comercial de CFD CFX 14.0 foi utilizado para simular os resultados. Um impelidor de pás inclinadas (PBT 45°, com bombeamento para baixo) foi simulado em regime turbulento. Os resultados obtidos pelas simulações CFD para o número de potência e bombeamento, e perfil da componente axial da velocidade são discutidos e comparados com dados experimentais (Machado et al. et al., 2011). A velocidade foi medida usando a técnica PIV (Particle Image Velocimetry). Uma significativa influencia foi observada em alguns parâmetros na determinação de importantes variáveis nos processos de mistura. De forma geral, a predição do perfil da velocidade é influenciada, de alguma forma, pela resolução da malha, pelo modelo de turbulência e pelo esquema de discretização / Abstract: The use of non-structured meshes has received recently considerable attention for discretization of the computational domain in CFD simulations (Vakili & Esfahany, 2009; Cabrales et al., 2011). The non-structured meshes (the most common are tetrahedral) allow adequate adaptation of irregular geometries and easy use of automated algorithms for mesh generation in most commercial CFD software. It has been consistently suggested in the literature that hexahedral meshes are preferred over tetrahedral. However, they can be used, provided that some care is taken to provide a good representation of the physical phenomena of the problem. Recently published works have been proving that if they are used with care, satisfactory results are obtained (Spogis & Nunhez, 2009). Most of works developed with the use of CFD simulation for mixing processes use hexahedral and to date tetrahedral do not have the same acceptance of hexahedral (Joaquim Junior et al., 2007) and part of this work is aimed at showing that they can provide good results when simulating mixing processes. Another objective of this work is to show the effect of mesh refinement in tetrahedral meshes. It is investigated the influence of the prismatic elements near wall on global parameters such as the Power and Flow numbers. An initial analysis of the sensitivity of some turbulence models (Standard k-? model, the shear stress transport (SST) and BSL-Reynolds stress model) and the discretization scheme on the flow field produced were also carried out in this work. In addition, simulations with different mesh resolutions were made using the multiple reference frame (MFR) approach; whereas other cases a sliding mesh modeling was provided for the impeller. The discretization schemes were limited to upwind, high resolution and blend factor, since other schemes do not work well with tetrahedral. The commercial CFD software CFX 14.0 was used to simulate the results. A pitched blade turbine (PBT 45°, down-pumping), was simulated in turbulent flow. The results obtained for the Power and Flow numbers, the axial velocity profile component of the model in CFD are discussed and compared with experimental data (Machado et al. et al., 2011). The velocity was measured using the PIV technique (Particle Image Velocimetry). A significant influence of some parameters is observed on the determination of some important variable mixing. In general, the predictions of the velocity profile are influenced in some way by the resolution of the mesh, turbulence model and the discretization scheme / Mestrado / Desenvolvimento de Processos Químicos / Mestre em Engenharia Química
|
164 |
Diseño de un reservorio circular de almacenamiento de agua potable ubicado en la ciudad de Lima de 2500 m3 de capacidadVillegas Herrera, Romel Adolfo 06 October 2021 (has links)
El presente trabajo de diplomatura tiene como objetivo general presentar el
predimensionamiento, análisis por cargas de gravedad y sísmicas, y el diseño estructural en
concreto armado de un reservorio de agua potable apoyado sobre el suelo ubicado en la
ciudad de Lima. El reservorio tiene forma circular y por requerimientos hidráulicos tiene un
volumen de 2500 m3, diámetro de 22 m y una altura de 7.5 m. El estudio de mecánica de
suelos consideró un suelo de perfil tipo S1 con una capacidad portante de 3.5 kg/cm2 y un
módulo de balasto de 2.5 kg/cm3. Este está compuesto por una losa de fondo, paredes
cilíndricas, una cúpula esférica en la parte superior y una viga tipo anillo que une la cúpula
con las paredes.
El análisis por cargas de gravedad y sismo del reservorio simplemente apoyado están
modelados tridimensionalmente en el programa SAP 2000, siguiendo exigencias y
estipulaciones de la Norma Técnica E.020, E.030 del año 2018 y el código ACI 350 06.3.
Para el diseño de la cúpula, paredes, viga tipo anillo y losa de fondo se consideran la norma
peruana E.060 y el código ACI 350-06.
|
165 |
Diseño estructural en concreto armado de un reservorio circular de almacenamiento de agua potable de 2700 m3 ubicado en la ciudad de LimaMontenegro Carrillo, Renzo Adolfo 01 February 2023 (has links)
El presente trabajo de suficiencia profesional tiene como objetivo general presentar el
predimensionamiento, el análisis por cargas de gravedad y sísmicas, y el diseño estructural
en concreto armado de un reservorio circular de almacenamiento de agua potable ubicado
en la ciudad de Lima. Dicho reservorio tiene una capacidad de 2700 m3, 25 m de diámetro
y una altura de 6.50 m.
El sistema de concreto para contención de líquidos consta de una losa de fondo, paredes
cilíndricas, una cúpula esférica en la parte superior y una viga tipo anillo que une la cúpula
con las paredes. Asimismo, toda la base de este reservorio está apoyada en un suelo de perfil
tipo S1 con un módulo de balasto de 2.0 kg/cm3.
Con respecto a las consideraciones especiales en el diseño en concreto armado de
reservorios tal como la calidad del concreto, el factor de durabilidad y fisuración, se siguen
las estipulaciones de la ACI 350-06 referente al Code Requirements for Environmental
Engineering Concrete Structures.
Por otro lado, para el análisis de cargas de gravedad y sísmico, así como el diseño estructural
del reservorio, se consideran tanto normas peruanas como internacionales, específicamente,
la Norma Técnica Peruana E.020 Cargas, E0.30 Diseño Sismoresistente, E.060 Concreto
Armado y el ACI 350.3-06 correspondiente al Seismic Design of Liquid-Containing Concret
Structures y, además, las ecuaciones provenientes del sistema mecánico equivalente
simplificado (Housner, 1963).
Como resultado de diseño de los elementos estructurales del reservorio, se obtiene un
espesor tanto para las paredes cilíndricas como del fondo de losa de 40cm. La cúpula fue
diseñada con un espesor de 7cm y una flecha de 2.50m y el anillo con una sección de 60x40
cm. Por último, ya concluido el diseño del reservorio, se realiza el control de fisuración por
flexión y tracción directa según los parámetros estipulados en la norma ACI 350.3-06.
|
166 |
Calidad de recepción de materia prima y aumento de eficiencia en recuperación de aceite a partir del agua de bombeo en una planta pesqueraAlva Rondón, José Luis 09 May 2011 (has links)
En este trabajo monográfico se quiere poder determinar mediante experiencias y el
análisis de otros trabajos realizados en diferentes empresas pesqueras a nivel
nacional; de los cuales se ha podido realizar una determinada recolección de datos
y mejores maneras del aprovechamiento en la recuperación de las grasas de la materia prima, en esta monografía se trata de dar algunas pautas para una adecuada programación en la recuperación de sólidos grasos en el agua de bombeo, la cual pasa a ser un tema importante a tratar ya que de acuerdo a los limites permisibles contenidos de grasa en este elemento, se está tratando de controlar las evacuaciones al mar con la menor diferencia de grasa posible
normándose mediante resoluciones dadas por el Ministerio de la Producción.
|
167 |
Practical implementation of fault detection scheme in a three tank systemCórdova Ricapa, Fernando 22 June 2016 (has links)
This thesis presents a practical implementation of fault detection scheme in a real
system by using residuals signals. These residuals have been generated applying the
method of a model-based fault diagnosis. Different approaches have been studied
and the corresponding algorithms developed. The object of the investigation is
the three tank system in which different kind of methods of fault detection were
performed. Various scenarios in which faults are simulated in actuators, sensors or
components are analyzed considering also the presence of noise. Due to the inherent
system characteristics it presents four possible work regions which are usually not
taken into account in literature, but studied in this thesis. Also special cases, when
the system goes from one region to another through critical points in which the
system presents singularities, are shown. Faults will be performed around the time
when the system states lie in the neighborhood of the critical points and the main
task is now to overcome these singularities and achieve successfully a fault detection. / Tesis
|
168 |
Efeitos do cultivo experimental de peixes em tanques-rede sobre a estrutura da comunidade fitoplanctônica em um braço do reservatório de Salto Caxias, região Sudoeste do Estado do Paraná / Effects of experimental fish farming in net cages on phytoplankton structure in an arm of Salto Caxias reservoir, Southeast of Paraná StateBartozek, Elaine Cristina Rodrigues 11 June 2012 (has links)
Made available in DSpace on 2017-07-10T18:13:32Z (GMT). No. of bitstreams: 1
Elaine C Rodrigues Bartozek.pdf: 1985797 bytes, checksum: a358025d50258b7eaddead48b3a3dc40 (MD5)
Previous issue date: 2012-06-11 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / In Brazil, hydroelectric powerplant reservoirs are used for multiple purposes, among them, fish farming in net cages. The present study aimed to evaluate spacial and temporal variations of the abiotic variables, nutrients concentration, trophic state and composition and structure of the phytoplankton community in an arm of Salto Caxias reservoir influenced by experimental fish cultivation in net cages. Samples were bimontly betweem September 2010 and July 2011 at the subsurface of the pelagic zone in four sampling stations, been two of them placed in the arm influenced by the cultivation of 30 net cages and the other two in the cagaless arm. No significant differences were observed for composition, diversity, density and phytoplankton biomass between the treatments. The results of the analisys performed showed only seasonal variations, separating the dry from the rainy period. The values of species richness and Shannon diversity were low during the entire study period. Evenness was high in the dry period and low in the rainy period. Both arms were classified as oligotrophic, possible demonstrating low influence of the net cages in the environment. Phytoplankton density and biomass were higher during the rainy period. The dry period was represented mainly for Bacillariophyceae taxa and the rainy period by Cyanobacteria and Chlorophyceae. Two functional groups (FG) were observed (FG F and K), both of them typical from shallow environments with high transparency water. Variations in the phytoplakton structure seem to have been influenced mainly by the seazonality. The effects of the net cages in the nutrients concentration and phytoplankton structure were probably low, possibly due to the low number of net cages and fishes emploied and environment dinamics, influenced by the inflows of the upstream rivers. / No Brasil, reservatórios de usinas hidrelétricas são utilizados para múltiplas propostas, entre elas, o cultivo de peixes em tanques-rede. O presente estudo objetivou avaliar as variações espaciais e temporais das variávies abióticas, concentração de nutrientes, estado trófico e da composição e estrutura da comunidade fitoplanctônica em um braço do reservatório de Salto Caxias influenciado pelo cultivo experimental de peixes em tanques-rede. Foram realizadas amostragens bimestrais, entre setembro de 2010 e julho de 2011, à subsuperfície da zona pelágica, em quatro estações de amostragem, sendo duas localizadas em um braço influenciado pelo cultivo em 30 tanques-rede e duas em um braço não influenciado. Não foram registradas diferenças significativas para a composição, diversidade, densidade e biomassa fitoplanctônica entre os tratamentos utilizados. Os resultados das análises realizadas evidenciaram apenas variações sazonais, separando o período seco do período chuvoso. Os valores de riqueza de espécies e diversidade de Shannon foram baixos durante todo o período de estudo. A equitabilidade foi elevada no período seco e baixa no período chuvoso. Ambos os braços foram classificados como oligotróficos, demonstrando possivelmente baixa influência dos tanques-rede sobre o ambiente. A densidade e biomassa fitoplanctônica foram maiores durante o período chuvoso. O período seco foi representado principalmente por táxons de Bacillariophyceae e o período chuvoso por Cyanobacteria e Chlorophyceae. Dois grupos funcionais (GF) fitoplanctônicos foram observados (GF F e K), ambos característicos de ambientes rasos e com elevada transparência da água. As variações da estrutura fitoplanctônica parecem ter sido influenciadas principalmente pela sazonalidade. Os efeitos dos tanques-rede sobre a concentração de nutrientes e estrutura da comunidade fitoplanctônica parecem ter sido pouco significativos, possivelmente devido ao pequeno número de tanques-rede e peixes utilizados e a hidrodinâmica dos ambientes estudados, influenciados pelos influxos dos rios à montante.
|
169 |
[en] STUDY ABOUT MARITIME OIL EXPORTS: METROLOGICAL ASPECT / [pt] ESTUDO SOBRE A EXPORTAÇÃO MARÍTIMA DE PETRÓLEO: ASPECTO METROLÓGICOROBERTO DA COSTA CARDOSO 07 January 2015 (has links)
[pt] Por muito tempo, os sistemas de medição dinâmica de petróleo não foram
usados para a transferência de custódia. Eles eram utilizados basicamente para
fins operacionais, como detectar vazamentos e transferências internas. O aumento
progressivo dos preços do barril de petróleo exigiu das medições de petróleo uma
incerteza cada vez menor, o que provocou o desenvolvimento de novas
tecnologias que resultaram em sistemas dinâmicos de medição de alta precisão a
serem utilizados na transferência de custódia. Nesta pesquisa foi avaliada a
substituição das medições estáticas por medições dinâmicas no faturamento de
exportações marítimas de petróleo, com o objetivo de agilizar as operações de
carregamento de navios em píeres diminuindo a indisponibilidade dos recursos
logísticos envolvidos, de minimizar a exposição da companhia a perdas
financeiras devido a faturamentos errôneos e de verificar que essa diminuição da
exposição justifica o investimento em sistemas de medição dinâmica. Foram
descritas as medições de tanques de terra, as medições de tanques de navio e os
sistemas de medição dinâmica, avaliando procedimentos, equipamentos, além de
restrições, problemas e incertezas associadas a cada método. Foi dada atenção
especial aos procedimentos de arqueação de tanques para armazenamento de
granéis líquidos, comparando procedimentos utilizados no Brasil pelo Inmetro aos
requisitos da Norma ISO -7507, e a rastreabilidade metrológica dos equipamentos
de medição em relação aos procedimentos utilizados na sua calibração. / [en] For many years, dynamic measurement systems have not been used in the
petroleum industry for custody transfer applications, only for operational reasons
like detecting leaks and internal transfers. The progressive growth of crude oil
prices required measurements with a smaller uncertainty, leading to developing
news technologies, resulting in high accuracy flow meters to be used in custody
transfer. The main objective of this research was evaluate the replacement of static
measurements by dynamic measurements in oil exports sales in order to speed up
the loading of vessels, decreasing the unavailability of logistical resources
involved, to minimize the company s exposure to economic losses due to
erroneous bill of ladings and verify if this justifies the investment in dynamic
measurement systems. This research has discussed a number of issues associated
with the uncertainty of the shore tanks, vessels tanks and dynamic measurements,
evaluating procedures, equipment, and restrictions, problems and accuracy
associated with each method. It also included a discussion about the difference
between calibration of vertical cylindrical tanks procedures used in Brazil by
Inmetro and the requirements of ISO -7507, and about traceability of measuring
equipment calibration.
|
170 |
Estudo de uma metodologia para o dimensionamento de um tanque de provas do tipo reboque. / Study of a methodology for the desing of a towink tank.Saldarriaga Muñoz, Jaime Miguel Mariano 17 December 2010 (has links)
Um tanque de provas do tipo reboque permite a realização de ensaios hidrodinâmicos com modelos em escala, sua presença é importante devido à possibilidade de obter características hidrodinâmicas que dimensionam a potência e qualidade do comportamento dos navios durante a sua operação, otimizando os projetos de forma particular ou geral, tanto para a navegação marítima, lacustre ou fluvial. O objetivo principal desta pesquisa é estudar e propor uma metodologia para o dimensionamento e concepção de um tanque de reboque para o Serviço Industrial da Marinha (SIMA PERU), principal estaleiro do Peru, de maneira que possa realizar os ensaios hidrodinâmicos correspondentes aos diferentes tipos de embarcações produzidas pelo SIMA PERU. Como propósito de estudo será desenvolvido uma análise de um tanque de reboque que permitirá ensaiar modelos de diferentes tipos de embarcações, levando em consideração as diferentes condições ambientais e climáticas relacionadas ao litoral peruano em toda sua extensão, isto é, uma condição marítima equivalente a uma escala Beaufort 5. Estas são as condições que foram requeridas para atuar na costa peruana. Será proposto um tanque de reboque com características próprias, baseado no razoável dimensionamento dos modelos reduzidos e nas necessidades e requerimentos de ensaio de acordo às recomendações apresentadas pela Conferência Internacional de Tanques de Reboque (International Towing Tank Conference- ITTC). / A towing tank allows hydrodynamic testing with scale models, their presence is important because allows to obtain hydrodynamics characteristics that they measure the power and quality of behavior during the operation, optimizing the designs in general or particular form of vessels for sea, lake or river. The main objective of this research is to study and propose a method for sizing and development of a towing tank for the Naval Industrial Service; SIMA - PERU, main shipyard from Peru, so it carry out hydrodynamics tests corresponding to different types of vessels produced by SIMA - PERU. The purpose of study will be developed analysis of a towing tank that will test models of different types of vessels, taking into account the different environmental and climatic conditions related to the Peruvian coast, in other words, sea conditions equivalent to a Beaufort \"5\". These are the conditions that were required to act on the Peruvian coast. Will be offered a towing tank with its own characteristics, needs and requirements based on the consistent sizing of reduced models and according to the recommendations made by the International Towing Tank Conference - ITTC.
|
Page generated in 0.064 seconds