• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1943
  • 190
  • 59
  • 33
  • 33
  • 32
  • 27
  • 26
  • 13
  • 8
  • 7
  • 4
  • 3
  • 3
  • 3
  • Tagged with
  • 2241
  • 1162
  • 243
  • 241
  • 201
  • 158
  • 126
  • 122
  • 122
  • 116
  • 104
  • 103
  • 102
  • 85
  • 84
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
271

Temperaturas Mínimas en el Valle de Casablanca: Descripción de su Variabilidad y Comparación con Resultados del Modelo WRF

Montes Verdugo, Carlo César January 2010 (has links)
No description available.
272

Características fermentativas e econômicas da produção de biogás utilizando dejetos de cabras leiteiras /

Biagioli, Bruno. January 2013 (has links)
Orientador: Kléber Tomás de Resende / Coorientador: Márcia Helena Machado da Rocha Fernandes / Banca: Jorge de Lucas Júnior / Banca: João Antônio Galbiatti / Banca: Silvio Doria de Almeida Ribeiro / Banca: Heraldo César Gonçalves / Resumo: Muitos fatores interferem na produção de biogás, mas pouco se sabe como eles interagem entre si ou qual é a melhor combinação entre eles. O objetivo deste estudo foi buscar a melhor combinação de fatores que podem ser manipulados a fim de otimizar a produção de biogás e também desenvolver equações capazes de predizer a produção de biogás e a produção de metano do dejeto caprino. Para avaliar a digestão anaeróbia de dejetos de cabras foram utilizados 24 biodigestores distribuídos em esquema fatorial 3x3x3x2, e considerados os seguintes fatores: temperatura (20,11ºC; 21,48ºC; 30,24ºC; 33,74ºC e 34,67ºC); pH (6,8; 6,84; 7,0; 7,15; 7,22); sólidos totais (2,63%; 3,53%; 4,46%; 6,85%; 6,87%) e da forma do dejeto (cíbalas inteira e cíbalas quebradas) em um desenho experimental composto central, submetidos a 49 dias de fermentação. A produção de biogás foi significativamente dependente da interação entre temperatura, pH e sólidos totais, cujo melhor volume de produção de biogás foi obtido nas condições de 34,67 ºC; pH 7 e 6,87% de sólidos totais, respectivamente, as equações de predição de biogás e metano podem ser utilizadas como forma de manejo e gerenciamento do capril / Abstract: Many factors affect the production of biogas, but is unknown how they interact each other or what is the best combination of then. The aim of this study was to seek the best combination of factors that can be manipulated to optimize biogas production and also develop equations capable of predicting the production of biogas and methane production of goat manure. To evaluate the anaerobic digestion of manure from goats, 24 digesters were used in a factorial scheme 3x3x3x2, and considered the following factors: temperature (20.11º C, 21.48º C, 30.24º C, 33.74º C and 34.67º C), pH (6.8, 6.84, 7.0, 7.15, 7.22), total solids (2.63%, 3.53%, 4.46%, 6.85%, 6.87%) and the form of manure (feces broken and whole) in a central composite design, submitted to 49 days of fermentation. The biogas production was significantly dependent on the interaction between temperature, pH and total solids, whose best volume of biogas production was achieved under the conditions of 34,67 ° C, pH 7 and 6.87% total solids, respectively, the equations prediction of biogas and methane can be used as a form of management and administration of the goat culture / Doutor
273

Uma investigação sobre o papel do interlocutor de libras como mediador em aulas de física para alunos com deficiência auditiva /

Almeida, Thiago Jose Batista de. January 2013 (has links)
Orientador: Eder Pires de Camargo / Co-orientador: Denise Fernandes de Mello / Banca: Luciano Gonsalves Costa / Banca: Roberto Nardi / Resumo: A investigação relatada se insere no contexto do ensino de física para alunos surdos mediado por interlocutor de Língua Brasileira de Sinais - LIBRAS. As interações investigadas foram: (a) interlocutor/aluno surdo; (b) docente/aluno surdo e (c) aluno ouvinte/surdo. Entende-se que a mediação pode se dar em torno de dois aspectos: o conteúdo de Física e as ações indiretas em relação ao conteúdo, tais como a organização da sala para procedimentos metodológicos. A presente pesquisa, de natureza qualitativa, utilizou como fonte de dados a filmagem da interpretação da Língua Portuguesa para a LIBRAS, realizada pela interlocutora em seis aulas, onde foram discutidos os principais tópicos que envolvem os conceitos de calor e de temperatura. A fim de compreender o que interpretado pela interlocutora, foi realizada a transcrição de sua interpretação para a Língua Portuguesa, estabelecida por uma professora intérprete de LIBRAS. Foi realizada também uma entrevista semiestruturada com a interlocutora, visando complementar os dados da pesquisa. As informações obtidas na filmagem indica que, em alguns momentos, há semelhanças, e em outros, diferenças entre a fala da professora e a tradução realizada pela interlocutora. Segundo nossa análise, as diferenças estão relacionadas a três fatores: 1. Pouco tempo de atuação da interlocutora, que possuía um vocabulário em LIBRAS ainda pouco expressivo, devida a sua formação em LIBRAS corresponder a um curso de 120 horas; 2. Dificuldade na interprestação dos conteúdos físicos, devido à interlocutora ter formação acadêmica em Letras e não em Física; 3. Ausência de sinais em LIBRAS dos conceitos físicos investigados. Conclui-se, dessa forma, que a mediação dos conteúdos físicos não foi satisfatória, sobretudo em função desses três pontos citados / Abstract: The research reported is in the physics teaching for hearing impaired studentes mediated by an Brazilian sing language (LIBRAS) interlocutor. The interaction researched were: (a) interpreter /deaf student; (b) Teacher/deaf student and hearing student/deaf student. It is understood that mediation can be related with two aspects: the physics component and the indirect actions related with the contempt as class organization to methodological procedures. This is qualitative research, filming of the interpretation from Portuguese into LIBRAS was used as a source for data. Those filming were made through six classes and the interpretation was done by the interpreter, in which there were discussed the main topics that involves concepts of heat and temperature. To understand what was interpreted by the interpreter, it was made, by a Libras teacher and interpreter, the transcription of that into Portuguese. It was also done a semi organized interview with the interpreter in order to complement the data of the research. The information obtained in the film shows that, in some moments, there are similarities and in others there are differences between the speech of the teacher and the translation made by the interpreter. According to our analysis, the differences were related to three factors: 1. Shor time of experience of the interpreter, who had gotten a little expressive vocabulary in LIBRAS, in due her formation in LIBRAS in a course of only 120 hours; 2. Difficulties in the interpretation of physics content, because of the interpreter formation in languages and not physics; 3. Lack of sings for researched physics content in LIBRAS. We concluded that the mediation of physics content in LIBRAS. We concluded that the mediation of physics content wasn't satisfactory, above all in due those points cited above / Mestre
274

Diseño de un contrastador de temperatura para termómetros de termocuplas tipo K

Bedoya Martínez, Daniel Arturo 18 February 2014 (has links)
Este trabajo de tesis muestra el diseño de un equipo contrastador de temperatura para el Laboratorio de Energía de Ingeniería Mecánica de la Facultad de Ciencias e Ingeniería de la PUCP. Cuando se habla de mediciones de temperatura, el instrumento más utilizado para este fin, es la termocupla, la cual muestra los valores de temperatura medidos, por medio de su termómetro digital acoplado. Este termómetro, con el tiempo y uso, suele descalibrarse y es responsabilidad del operario del instrumento efectuar calibraciones periódicas del aparato con el fin de asegurar la confiabilidad de las mediciones. Por ese motivo se diseñó, en este trabajo, un equipo contrastador térmico de una termocupla tipo K. Este dispositivo simula el comportamiento de dicha termocupla y podrá ser acoplado a los termómetros digitales, permitiendo a los usuarios de tales termómetros, contrastarlos, para determinar si necesitan calibrarse. El equipo permitirá el ingreso de valores con saltos de 10 ° C, y tendrá un rango de - 30 a 250 ° C. Para el presente proyecto, primero se identificó las partes más importantes que conforman tales equipos, y posteriormente con ayuda de un diagrama de bloques se diseñó la estructura interna del simulador. Para cada parte del diagrama se hizo una selección de componentes que permitieron cumplir con los requisitos de cada bloque respectivo. Seguidamente se escogió, justificando con los debidos criterios de selección, los componentes más apropiados para cada bloque. Una vez escogidas todas las partes del diagrama se procedió a realizar simulaciones de determinados bloques junto con un análisis de error, de cada uno de los componentes, para conocer la máxima desviación o el máximo error que se podría obtener en la salida del equipo, consiguiendo un valor satisfactorio de error igual a 1.78 ° C, en el peor de los casos. Es importante mencionar que este proyecto se llevó a cabo con el fin de ser una referencia para personas que deseen efectuar una investigación más profunda en lo que respecta a la generación de centenas de microvoltios de un transductor.
275

Desenho urbano climaticamente orientado: a influência da vegetação no ambiente térmico externo

Minella, Flávia Cristina Osaku 01 August 2014 (has links)
CAPES / A vegetação pode produzir efeitos positivos mensuráveis no campo térmico dos recintos urbanos. Diante das inadequações térmicas verificadas nos espaços citadinos, existe a necessidade de projetos e planos urbanos que considerem a utilização da vegetação como elemento estratégico para a criação de condições de conforto térmico em espaços abertos. Nesse sentido, a pesquisa assume relevância ao propor um índice que identifique a quantidade de cobertura vegetal necessária para reduzir a temperatura do ar em ambientes urbanos. O índice foi desenvolvido para a cidade de Curitiba, especialmente para a Avenida Sete de Setembro e a Avenida Linha Verde. Adicionalmente, são apresentados estudos pilotos para as cidades de Genebra, Paris e São Paulo. De caráter experimental, a pesquisa utiliza medições em campo para coleta de dados microclimáticos e simulação computacional com o modelo ENVI-met, o qual viabilizou a comparação entre cenários atuais e cenários alternativos. Todas as simulações foram realizadas considerando situações de verão. Os índices Temperatura Fisiológica Equivalente (PET) e Universal Thermal Climate Index (UTCI) foram utilizados para avaliar os níveis de estresse térmico na escala do pedestre. De forma geral, observou-se que a inserção de áreas arborizadas (especialmente sob copa densa) poderia reduzir o potencial de aquecimento das áreas urbanas no período diurno, com mudanças substanciais nas categorias de estresse térmico. A máxima redução na temperatura do ar conseguida foi de 2,5°C, verificada nos estudos piloto de São Paulo e Paris. Na Sete de Setembro a redução máxima de temperatura do ar foi de 1,2°C e na Linha Verde foi de 1,5°C. Verificou-se que os fatores que contribuem para reduções na temperatura ambiente são a forma de distribuição das árvores e a densidade da copa (fator relacionado à qualidade da sombra). O índice proposto (proporção entre cobertura vegetal e a área construída) pode explicar a redução média de Ta em 83,1%. A partir da aplicação do mesmo, pode-se concluir que a redução de 1°C na temperatura do ar deve ser esperada para um aumento de 49% de cobertura vegetal. Em cidades com ocorrência de ondas de calor, a vantagem de um plano de arborização é o custo relativamente baixo de implantação se considerar o benefício na redução das categorias de estresse térmico. A importância do índice (e da metodologia proposta para seu desenvolvimento) reside na possibilidade da sua aplicação no desenho urbano climaticamente orientado. / Vegetation can produce measurable positive effects on the thermal field of urban spaces. In view of thermal inadequacies in outdoor spaces, there is a need for projects and urban plans which consider the use of vegetation as strategic element for the creation of thermal comfort conditions in open spaces. In this sense, the relevance of this study is the proposition of an index which estimates the amount of vegetation fraction needed to reduce the air temperature in urban environments. The index was developed for the city of Curitiba, specifically for its central arteries such as Avenida Sete de Setembro and Avenida Linha Verde. Additionally, pilot studies for the cities of Geneva, Paris and São Paulo are presented. The experimental research uses field measurements for collecting microclimatic data and computer simulations with the ENVI-met model, which allowed the comparison of current and alternative scenarios. All simulations were carried out for summer conditions. The thermal comfort indices Physiological Equivalent Temperature (PET) and Universal Thermal Climate Index (UTCI) were used to assess levels of thermal stress at the pedestrian level. In general, it was observed that the insertion of green areas (particularly under dense canopy) could reduce the daytime heating in urban areas, with substantial changes in heat stress categories. The maximum reduction of air temperature was 2.5°C, observed in the pilot studies in São Paulo and Paris. In the Sete de Setembro the maximum reduction of air temperature was 1.2°C and in the Linha Verde it was 1.5°C. It was found that contributing factors to ambient temperature reductions are the distribution of trees and the canopy density (related to the shadow quality). The proposed index (ratio between the increase of vegetated over built-up area) may explain the reduction of mean air temperature by 83.1%. From its application, it can be concluded that a 1°C reduction in air temperature should be expected for an increase of 49% in vegetated fraction. In cities impacted by heat waves, the advantage of greenery insertion is the relatively low investment with considerable benefits in changes of heat stress categories. In cities impacted by heat waves, the advantage of greenery insertion is the relatively low investment with considerable benefits in changes of heat stress categories. The importance of the index (and the proposed methodology behind it) lies in the possibility of its application in climate- responsive urban design.
276

Ciclo reprodutivo de fêmeas de Devario aequipinnatus (Cypriniformes, Cyprinidae) submetidas a diferentes temperaturas /

Silva, Laíza Maria de Jesus. January 2016 (has links)
Orientador: Rosicleire Veríssimo-Silveira / Resumo: A influência antrópica vem crescendo continuamente no ambiente assim os impactos negativos nos ambientes causam alterações sobre a distribuição e abundância das espécies aquáticas se estendendo de pequenos córregos a grandes rios. Em teleósteos, a gametogênese é um processo altamente complexo, modulado pelas variações ambientais e fisiológicas. Desta forma, o presente estudo teve por objetivo avaliar a influência de três diferentes temperaturas sobre o desenvolvimento ovariano de Devario aequipinnatus. Foram utilizadas exemplares fêmeas e adultas de Devario aequipinnatus e para a condução do experimento foram utilizados 3 aquários com capacidade para 9 L, mantidos a 18°C, 24°C e 30°C, o experimento foi realizado com uma temperatura a cada período. Cinco indivíduos de cada tratamento foram coletados de modo aleatório a cada quatro dias, no período entre o 1° e 37° dia experimental nas temperaturas de 24°C e 30°C e no período entre o 1° e 33° dia na temperatura de 18°C. O material coletado foi processado conforme técnicas usuais para microscopia de luz. Na foliculogênese, as células oogônias, são as menores da linhagem germinativa e passam pelas diferentes fases da profáse meiótica. Na oogênese, os estágios foram classificados em previtelogênese inicial e final, vitelogênese inicial e final e por fim maturação. Já as fases reprodutivas foram classificadas em Regeneração, Desenvolvimento inicial e final, Apto à desova e Regressão. Desta forma foi verificado que na temperatura de... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The antropogenic influence has grown continuously in the environment, thus negative impacts on the environment cause changes on the distribution and abundance of aquatic species extending from small streams to large rivers. In teleosts, gametogenesis is a highly complex process, modulated by environmental and physiological changes. This study aimed to evaluate the influence of three different temperatures on ovarian development of Devario aequipinnatus. They were used adult females specimens, and for the experiment were used three aquariums with a capacity of 9 L, kept at 18°C, 24°C and 30°C, the experiment was conducted with a temperature of each period. Five individuals from each treatment were collected randomly every four days in the period between 1st and 37th experimental day at temperatures of 24°C and 30°C and the period between 1st and 33th day at temperature of 18°C. The material were processed according to the usual techniques for light microscopy. In folliculogenesis, the oogonia, cells are the smallest of the germ line and go through different stages of meiotic prophase. In oogenesis, stages were classified into initial and final previtelogenic, initial and final vitellogenesis and maturation. Already reproductive phases were classified into Regenerating, initial and final Developing, Spawning Capable and Regressing. Thus, it was found that at 24°C (T24) of final Developing and Spawning capable phases were observed. However, in other temperatures, 18°C (T18) and ... (Complete abstract click electronic access below) / Mestre
277

Elaboración de herramientas necesarias para calificar y validar un sistema de embalaje para la distribución de productos farmacéuticos que requieren mantención de la cadena de frío

López Requena, Pablo Esteban January 2015 (has links)
Unidad de práctica para optar al título de Químico Farmacéutico / Autor no autoriza el acceso a texto completo de su documento / En el presente trabajo se llevó a cabo la elaboración de herramientas necesarias para calificar y validar un sistema de embalaje cuya finalidad es la distribución de productos farmacéuticos que requieran mantención de la cadena de frío, cuya investigación y desarrollo se efectuó durante el período abril-noviembre del año 2014 en las instalaciones de Laboratorios Pharma Isa Ltda. Quilicura. Se evaluó y determinó de qué forma se transportarán los productos farmacéuticos que distribuye Laboratorio Pharma Isa Ltda., para que no pierdan la cadena de frio. Se evaluó los tipos de cajas de aislapol (cajas térmicas) que existen en el medio local, y determinó cuales se usarán en Laboratorio Pharma Isa Ltda., para transportar los productos. Se elaboró y desarrolló distintos sistemas de embalaje en el despacho de productos refrigerados incluyendo configuración y caja térmica. Se elaboró, desarrolló y estableció un instructivo del armado interno de cada caja térmica dependiendo si el despacho es para Santiago o para regiones fuera de Santiago. Se llevó a cabo la calificación de funcionamiento o desempeño (en inglés Performance Qualification, PQ) del sistema de despacho de productos refrigerados. Se evaluaron los datos obtenidos (repetibilidad de los datos) de cada una de las pruebas realizadas como parte del protocolo de calificación y determinó de acuerdo al veredicto final del proceso si cumplió o no con la calificación. De los resultados obtenidos, queda establecido que el sistema de embalaje de despacho de productos refrigerados dentro de Santiago asegura la cadena de frío por ocho horas, quedando calificado el sistema. Sin embargo, para el envío de productos a regiones fuera de Santiago, los despachos cuyos sistemas de embalaje poseen una capacidad de carga media (10 productos) y máxima (20 productos) cumplen con la calificación de desempeño, no así, el sistema de embalaje con capacidad de carga mínima (1 producto) que necesita ser nuevamente estudiado y evaluado, considerando para aquello la incorporación de medidas correctivas
278

Estudio Electromagnético, Térmico, Hidráulico y de los Efectos Sobre Seres Vivos de un Equipo para Calentamiento de Fluidos por Inducción Magnética

Otárola Lagos, Inés del Carmen January 2010 (has links)
En este trabajo se desarrolló un modelo que permite estudiar mediante simulaciones computacionales, las variables electromagnéticas, térmicas e hidráulicas involucradas en la operación de un equipo para calentamiento de fluidos utilizando el principio de inducción magnética. Esta tecnología presenta ciertas ventajas en comparación a los métodos actuales de calentamiento de fluidos, como por ejemplo que requiere de menos espacio y posee menores costos de mantenimiento. Sin embargo, es necesario tener la certeza de que el campo magnético generado por el equipo en su entorno no exceda los valores máximos recomendados por organismos internacionales. Estas recomendaciones surgieron a partir de diversos estudios relativos al tema, que han definido como seguros valores de intensidad de campo magnético que no producirán efectos sobre los seres vivos expuestos a ellos. Para el desarrollo de esta tesis se realizó, en primer lugar, una revisión bibliográfica del estado del arte sobre la investigación de efectos de campos electromagnéticos sobre seres vivos y las normas internacionales relacionadas con los límites máximos de exposición a estos campos. A continuación se desarrolló un modelo en COMSOL Multiphysics, que permite simular, desde el punto de vista eléctrico, térmico e hidráulico, un sistema de calentamiento por inducción magnética (CIM) para una configuración dada. Luego, en una planta de CIM piloto de 15 kW de potencia, se realizaron mediciones experimentales de la temperatura del agua y de los campos alrededor del equipo, con el fin de validar el modelo de simulación desarrollado, el cual, por limitaciones de capacidad computacional se desarrolló en un escenario bidimensional, encontrándose una muy buena concordancia entre ambos tipos de resultados. Una vez evaluado y validado el modelo, fue posible extender la metodología para predecir los valores que se obtendrían para las variables en una planta semi-industrial de 500 kW, con una determinada configuración. En relación a la generación de campos en torno al equipo, se pudo comprobar que los valores de los campos alrededor de la planta piloto de 15 kW cumplen con lo exigido por las normas internacionales, mientras que para la planta semi-industrial de 500 kW, se determinó que esto comienza a cumplirse a partir de cierta distancia desde el equipo. El trabajo fue desarrollado en el marco del proyecto Fondef D05I-10098 “Mejoramiento de Operaciones de Biolixiviación de Minerales de Cobre y Electro-Obtención en Plantas a Gran Altura Mediante Calentamiento de Soluciones por Inducción Magnética”, en el que participan la Universidad de Chile, Universidad Técnica Federico Santa María y las empresas IDT S.A. y Anglo American Chile.
279

Implementation of a four probes measuring system to determine the resistivity of thin lms with temperature dependence

Salas Casapino, Carlos Alberto 28 June 2017 (has links)
Resistivity measurements in thin film samples depending on the temperature and on the film thickness is always a subject of interest, above all when it comes to new materials. This work presents the implementation of a measuring system for thin film resistivity based on four probes showing the dependency of the resistivity on the temperature as well as on the film thickness. In order to change the temperature of the samples, a heat source based on a Peltier element was implemented into the measuring system. A Graphical User Interface using a LabVIEW software controls all the devices of the measuring system and allows the user to calculate the thin film resistivity choosing between four measuring method: Van der Pauw, Modified Van der Pauw, Linear Van der Pauw and Linear Four Probes methods. Resistivity in aluminum and tungsten thin film samples with 100, 300, and 600 nm thickness were measured at temperatures between 303K and 373K with increments of 5 K. The results obtained are higher than bulk resistivity values and agrees with the present theory. Moreover, it is shown that the resistivity values obtained and its corresponding temperature coefficients increases as the film thickness decreases. / Tesis
280

Calificación de camiones y validación de embalajes para transporte de productos refrigerados en una empresa de logística farmacéutica

Valdés Muñoz, Evelyn Solange January 2014 (has links)
Unidad de práctica para optar al título de Químico Farmacéutico / No autorizada por el autor para ser publicada a texto completo en el Portal de Tesis Electrónicas / En el presente trabajo se llevó a cabo la calificación de los camiones de transporte refrigerado pertenecientes a la Droguería Perilogistics con la finalidad de obtener evidencia objetiva y documentada de que los sistemas de refrigeración instalados funcionan correctamente, siendo seguro y eficaz su uso para el despacho y/o retiro de productos que requieren conservación a temperatura controlada. Se elaboró un protocolo de calificación donde se hace una descripción de los camiones y de sus unidades de refrigeración en base a los manuales de los proveedores. Luego, se realizó la calificación de instalación (en inglés Installation Qualification, IQ), calificación de operación (en inglés Operational Qualification, OQ) y calificación de desempeño (en inglés Performance Qualification, PQ). Con los resultados se redactaron los informes finales, dando por aprobado con base documentada la calificación de los camiones. Por otro lado, se realizó la revalidación del proceso de embalaje de productos refrigerados usado para despacho de productos dentro de Santiago y en regiones. Todo esto en época estival, como lo indica el plan maestro de validación. Durante este proceso se reconfiguró la forma de embalar para hacer más eficiente el proceso y la duración de la mantención de la cadena de frío. Para probar su eficacia los embalajes fueron enviados a ruta dentro de la ciudad de Santiago y a regiones, usando distintos tipos de embalajes: Ostra, Erizo y Laboratorio. Todos ellos con sensores TempTale 4 en su interior para observar el comportamiento real, bajo condiciones normales. De los resultados obtenidos, queda establecido que las cajas usadas dentro de Santiago aseguran una hora de mantención de la cadena de frío para los medicamentos que son despachados con urgencia en caja Ostra, y, en el caso de los embalajes para despachos normales usando la caja Erizo, se asegura por tres horas la mantención de la cadena de frío. Para el envío de productos a regiones, utilizando cajas Laboratorio, se asegura 24 horas de mantención de la cadena

Page generated in 0.273 seconds