1 |
An EPROM based waveform generator for a CCD test stationHsieh, Long-Bing January 1988 (has links)
No description available.
|
2 |
Detekce kyslíku pomocí senzoru plynů / Oxygen detection using gas sensorJelínek, Tomáš January 2012 (has links)
In this master´s thesis various types of gas sensors, their characteristics, principle, active layer and structure are described. This work is focused on semiconductor gas sensors. In the experimental part gas test station is used to measure the main characteristic of commercial sensor Figaro TGS 822 and own SnO2 gas sensors and reaction to oxygen. Both sensors and measurement results are compared with each other.
|
3 |
Selftest pro automatický průmyslový tester / Self-Test for Automatic Industrial TesterKyselý, Tomáš January 2017 (has links)
Work discusses about the test station in NXP Semiconductors Company in Rožnov pod Radhoštěm. It describes first the test station itself and its possibilities in software libraries testing. Second it describes automatic selftest of this station and sub-steps of this selftest. This work is also used as a documentation for company needs. KEYWORDS
|
4 |
Senzory plynů, jejich konstrukce a testování / Gas sensors, their construction and testingPytlíček, Zdeněk January 2010 (has links)
This work deals with branch of gas sensors, their construction and methodology of testing. The general aim is a design and implementation of a station for simple testing of conduction gas sensors. The whole station is conceived as virtual measuring apparatus, operated by PC in LabView environment. The station enables mixing of any two gases at concentration demanded and measuring of the basic conduction characteristics of the thick-film and thin-film gas sensors. The central communication interface and modular conception enable easy expansion of possibilities of the whole apparatus in the future. It is possible to measure up to eight gas sensors split into two TO-12 packages simultaneously.
|
5 |
Teststation för industriella UV-celler / Test station for industrial UV-cellsAhmed, Masud Omar January 2019 (has links)
GE Healthcare Bio-Sciences AB in Umeå produce a variety of chromatography systems. One of the main components in chromatography is the UV module, which measure the light absorption of different wavelengths in the liquid being pumped through a cell. Currently at the Umeå site two types of UV-cells are produced; lab cells and industrial cells. The current test station for the industrial UV-cells is outdated, in disrepair and no longer supported. GE has developed a test station for the lab cells that evaluates UV and flow properties, the data is stored in GE’s own production database, Prodas. The aim of this work is to design a test station for industrial UV-cells to improve the quality of the cells. The primary goal is a test station that can measure pressure, flow and absorption. The secondary goal is to discover and if possible, implement solutions that will streamline and automate the test station. A prototype of a test station for industrial UV-cells based on that for lab cells has been developed. The solution consists of an adapter that links the light path from the monitor through the UV-cell to the detector. The test station can measure pressure, flow and absorption but can only perform absorption and leakage tests. Automation and efficiency have been accomplished in the form of scripts used to conduct absorption and leakage tests. The test station requires further development before it can be used in the production line. / GE Healthcare Bio-Sciences AB i Umeå tillverkar ett flertal system, ett av systemen är vätskekromatografen. Vätskekromatografen är en kemisk separationsmetod som använder sig av en UV-monitor, UV-detektor och en UV-cell för att mäta absorptionen av en lösning och framta koncentrationen av det eftersökta ämnet. På anläggningen i Umeå tillverkas två typer av UV-celler; laborationceller och industriceller. För labbcellerna har GE utvecklat en teststation som testar och utvärderar UV och flödesegenskaper samt lagrar data i GE:s egen produktionsdatabas, Prodas. Den befintliga stationen för industriceller är äldre och omodern, en utveckling behövs för att upprätthålla högre kvalité. Syftet med detta projekt är att uppdatera teststationen för industriella UV-celler till samma nivå som stationen för laborationsceller. Det primära målet är att konstruera och designa en teststation för industriella UV-celler som kan mäta tryck, flöde och absorption. Det sekundära målet är att upptäcka och om möjligt verkställa lösningar som kommer effektivisera och automatisera mätningarna. En prototyp av en teststation för industriella UV-celler baserat på den för laborationceller har framtagits, och består av en adapterlösning som används för att sammanlänka ljusbanan från monitorn genom flödescellen till detektorn. Prototypen kan enbart utföra absorption och läckagemätningar. Automatisering och effektivisering har utförts i form av scripts som används för att genomföra absorptions och läckagemätning. Teststationen kräver fortsatt vidareutveckling innan den kan används i produktionslinjen.
|
Page generated in 0.1153 seconds