Spelling suggestions: "subject:"electroanalytical"" "subject:"bioanalytical""
21 |
Desenvolvimento de método para determinação de nitrosaminas em águas de interesse à saúde pública / Method development for the determination of nitrosamines in water of interest to public healthNascimento, Heliara Dalva Lopes do 05 December 2003 (has links)
Entre os compostos orgânicos tóxicos possíveis de serem encontrados em águas de consumo humano, estão as nitrosaminas, substâncias nitrogenadas originárias da reação de aminas com compostos nitrosantes e de dificil detecção pelos métodos convencIOnaIs. O objetivo deste estudo foi desenvolver uma metodologia de rotina alternativa para a determinação de nitrosaminas em águas e a aplicação deste procedimento em algumas amostras de interesse à Saúde Pública. Um minucioso estudo e otimização dos parâmetros envolvidos na detecção e separação cromatográfica empregando o detector de quimiluminescência induzida por ozônio ou Thermo Energy Analyser (TEA), permitiram melhorar em 10 vezes a sensibilidade deste equipamento, permitindo assim a análise de traços de nitrosaminas, com o auxílio de uma pré-concentração da amostra e sem a necessidade do dessorvedor térmico. Comparativamente a outros detectores, o uso do GCffEA elimina as várias etapas necessárias para a descontaminação de material, requisitadas no uso do NPD e apresenta sensibilidade compatível com as técnicas de espectrometria de massas empregadas (High Resolution Mass Spectroscopy (HRMS) e Positive Chemical Ionization Mass Spectroscopy (PCI MS)), com a vantagem de uma operação mais simples e de menor custo. Para o alcance do objetivo, a utilização do planejamento de experimentos foi uma ferramenta fundamental. Por intermédio dela, os parâmetros críticos, como o fluxo de gases, temperatura de pirólise, etc. das principais etapas envolvidas no processo analítico, puderam ser estudados e otimizados. A metodologia proposta para a análise de traços de nitrosaminas em águas empregando GC/TEA mostrou boa especificidade, linearidade e precisão adequada com coeficientes de variação, na análise cromatográfica, na faixa entre 6 a 12% para as nitrosaminas voláteis analisadas. Considerando o propósito das análises, os limites de detecção alcançados foram adequados, como por exemplo, 0,2 ngL-l para a N-nitrosopiperidina e 2,0 ngL-I para a N-nitrosopropilamina levando em conta a recuperação obtida na etapa de pré-concentração. O método foi aplicado em amostras de água tratada, água bruta de reservatório e de rio, água de poço artesiano e extratos orgânicos provenientes de amostras de águas bruta e tratada. Algumas nitrosaminas voláteis de interesse toxicológico foram detectadas, como por exemplo, a N-nitrosodimetilamina (NUMA), que foi encontrada, dependendo da amostra, em concentrações menores que 0,3 ngL-1, limite de detecção, até 5,0 ngL-1. / Among the poisonous organic compounds liable to be found in waters of human consumption, are the nitrosamines, nitrogenous substances originated from amine reaction with nitrousing compounds, and of difficult detection by the conventional methods. The scope of this study was to develop an altemative routine methodology for the nitrosamine determination in waters and the application of this procedure in some samples of interest to the Public Health. A meticulous study and optimization of the parameters involved in the detection and chromatographic separation using a chemiluminescense detector induced by ozone or Thermo Energy Analyser (TEA), allowed a 10 times improvement in the sensibility of this equipment, allowing trace analysis of nitrosamines, with the aid of a pre-concentration of the sample and without the need of the thermal desorber. Comparing to other detectors, the use of GC/TEA eliminates several necessary stages for material decontamination, required in the use of NPD and it comparable presents sensibility with such Mass Spectrometric techniques as High Resolution Mass Spectroscopy (HRMS) and Positive Chemical Ionization Mass Spectroscopy (PCI MS), with the advantage of simpler operation at lower cost. To achieve the objective, the use of statistical of experimental design was a fundamental tool. By means of it, the criticall parameters, such as the gas flow rate, pyrolysis temperature, among others involved in the analytical process, could be studied and optimized. The methodology proposed for the analysis of nitrosamine traces in waters using GC/TEA showed good specificity, linearity and appropriate precision with a coefficient variation, in the chromatographic analysis, in the range between 6 and 12% for the analyzed volatile nitrosamines. Considering the purpose of the analyses, the detection limits reached were appropriate, as for instance, 0,2 ngL-1 for N-nitrosopyperidine and 2,0 ngL-1 for N-nitrosopropylamine taking into account the recovery obtained in the pre-concentration stage. The method was applied to samples of treated water, raw water of reservoirs and rivers, water of artesian wells and organic extracts coming from samples of treated and raw waters. Some volatile nitrosamines of toxicological interest were detected, as for instance, N-nitrosodimethylamine (NDMA), that was found, depending on the sample, in concentrations below the 0,3 ngL-1 (detection limit) till up to 5,0 ngL-1.
|
22 |
Desenvolvimento de método para determinação de nitrosaminas em águas de interesse à saúde pública / Method development for the determination of nitrosamines in water of interest to public healthHeliara Dalva Lopes do Nascimento 05 December 2003 (has links)
Entre os compostos orgânicos tóxicos possíveis de serem encontrados em águas de consumo humano, estão as nitrosaminas, substâncias nitrogenadas originárias da reação de aminas com compostos nitrosantes e de dificil detecção pelos métodos convencIOnaIs. O objetivo deste estudo foi desenvolver uma metodologia de rotina alternativa para a determinação de nitrosaminas em águas e a aplicação deste procedimento em algumas amostras de interesse à Saúde Pública. Um minucioso estudo e otimização dos parâmetros envolvidos na detecção e separação cromatográfica empregando o detector de quimiluminescência induzida por ozônio ou Thermo Energy Analyser (TEA), permitiram melhorar em 10 vezes a sensibilidade deste equipamento, permitindo assim a análise de traços de nitrosaminas, com o auxílio de uma pré-concentração da amostra e sem a necessidade do dessorvedor térmico. Comparativamente a outros detectores, o uso do GCffEA elimina as várias etapas necessárias para a descontaminação de material, requisitadas no uso do NPD e apresenta sensibilidade compatível com as técnicas de espectrometria de massas empregadas (High Resolution Mass Spectroscopy (HRMS) e Positive Chemical Ionization Mass Spectroscopy (PCI MS)), com a vantagem de uma operação mais simples e de menor custo. Para o alcance do objetivo, a utilização do planejamento de experimentos foi uma ferramenta fundamental. Por intermédio dela, os parâmetros críticos, como o fluxo de gases, temperatura de pirólise, etc. das principais etapas envolvidas no processo analítico, puderam ser estudados e otimizados. A metodologia proposta para a análise de traços de nitrosaminas em águas empregando GC/TEA mostrou boa especificidade, linearidade e precisão adequada com coeficientes de variação, na análise cromatográfica, na faixa entre 6 a 12% para as nitrosaminas voláteis analisadas. Considerando o propósito das análises, os limites de detecção alcançados foram adequados, como por exemplo, 0,2 ngL-l para a N-nitrosopiperidina e 2,0 ngL-I para a N-nitrosopropilamina levando em conta a recuperação obtida na etapa de pré-concentração. O método foi aplicado em amostras de água tratada, água bruta de reservatório e de rio, água de poço artesiano e extratos orgânicos provenientes de amostras de águas bruta e tratada. Algumas nitrosaminas voláteis de interesse toxicológico foram detectadas, como por exemplo, a N-nitrosodimetilamina (NUMA), que foi encontrada, dependendo da amostra, em concentrações menores que 0,3 ngL-1, limite de detecção, até 5,0 ngL-1. / Among the poisonous organic compounds liable to be found in waters of human consumption, are the nitrosamines, nitrogenous substances originated from amine reaction with nitrousing compounds, and of difficult detection by the conventional methods. The scope of this study was to develop an altemative routine methodology for the nitrosamine determination in waters and the application of this procedure in some samples of interest to the Public Health. A meticulous study and optimization of the parameters involved in the detection and chromatographic separation using a chemiluminescense detector induced by ozone or Thermo Energy Analyser (TEA), allowed a 10 times improvement in the sensibility of this equipment, allowing trace analysis of nitrosamines, with the aid of a pre-concentration of the sample and without the need of the thermal desorber. Comparing to other detectors, the use of GC/TEA eliminates several necessary stages for material decontamination, required in the use of NPD and it comparable presents sensibility with such Mass Spectrometric techniques as High Resolution Mass Spectroscopy (HRMS) and Positive Chemical Ionization Mass Spectroscopy (PCI MS), with the advantage of simpler operation at lower cost. To achieve the objective, the use of statistical of experimental design was a fundamental tool. By means of it, the criticall parameters, such as the gas flow rate, pyrolysis temperature, among others involved in the analytical process, could be studied and optimized. The methodology proposed for the analysis of nitrosamine traces in waters using GC/TEA showed good specificity, linearity and appropriate precision with a coefficient variation, in the chromatographic analysis, in the range between 6 and 12% for the analyzed volatile nitrosamines. Considering the purpose of the analyses, the detection limits reached were appropriate, as for instance, 0,2 ngL-1 for N-nitrosopyperidine and 2,0 ngL-1 for N-nitrosopropylamine taking into account the recovery obtained in the pre-concentration stage. The method was applied to samples of treated water, raw water of reservoirs and rivers, water of artesian wells and organic extracts coming from samples of treated and raw waters. Some volatile nitrosamines of toxicological interest were detected, as for instance, N-nitrosodimethylamine (NDMA), that was found, depending on the sample, in concentrations below the 0,3 ngL-1 (detection limit) till up to 5,0 ngL-1.
|
23 |
Caracterização termoanalítica e estudo de cura de compósito de resina epóxi e mica com propriedades elétricas isolantes aplicado em máquinas hidrogeradoras / Thermoanalytical Charactherization and Cure Study of an Epoxy resin and Mica Composite with Insulating Electrical Properties applied in Hydrogenerators MachinesTamy Koreeda 11 March 2011 (has links)
Atualmente, a participação da energia elétrica na matriz energética mundial é um assunto em evidência. O estudo do compósito isolante da barra estatórica, um dos componentes principais da máquina hidrogeradora, permite a obtenção de informações físico-químicas relevantes ao aperfeiçoamento do sistema, e também de estudos de comportamento térmico quando este é exposto à alta temperatura, por diferentes intervalos de tempo submetidos a estresses mecânicos, elétricos e/ou químicos. O sistema em estudo é o MICALASTIC®, desenvolvido pela empresa Siemens em 1960. Neste trabalho, as propriedades térmicas do compósito isolante, formado por uma fita de mica, resina epóxi (DGEBA), endurecedor (MHHPA) e acelerador naftenato de zinco (N-Zn) foram estudadas. Utilizando-se as técnicas termoanalíticas Calorimetria Exploratória Diferencial (DSC) e Termogravimetria e Termogravimetria Derivada (TG/DTG), o comportamento térmico de cada um dos materiais foi avaliado. As curvas DSC e TG/DTG também evidenciaram as possíveis interações químicas entre os componentes. Os estudos referentes à cura do material e da degradação térmica do compósito curado foram realizados. Observou-se claramente a influência da quantidade de acelerador na polimerização do sistema. A partir das curvas DSC, observou-se dois mecanismos de cura diferentes coexistentes, um com menor quantidade de N-Zn e outro com concentração maior, resultando em eventos de cura com início em temperaturas diferentes. Esse fato ainda não havia sido estudado desde a origem do sistema. Além disso, a perda de massa referente à evaporação do endurecedor no início do processo de cura foi confirmada a partir da caracterização do compósito por espectroscopia de absorção na região do infravermelho, comparando-se os espectros antes e após o fenômeno. Na prática, dois perfis de impregnação, o Homogêneo e o Heterogêneo, de barras condutoras são utilizados, e uma diferença significativa entre eles foi observada. Os estudos desenvolvidos devem ser associados a testes elétricos específicos para o melhor entendimento da relação entre a aplicação do material e suas propriedades teóricas termoanalíticas. Além disso, foi realizado o estudo cinético da decomposição térmica do compósito curado por métodos termogravimétricos, isotérmico e dinâmico. / Currently, the electric energy participation in the world energy matrix is a significant issue. The insulating composite in stator bars, which are one of the most important components in hydrogenerator machines, allows the attainment of relevant physical and chemical information to system optimization, in addition to study thermal behavior when the material is exposed to high temperatures, for different time intervals and mechanical, chemical and/or electrical stress. The studied system is MICALASTIC®, developed by Siemens Company in 1960. In this work, thermal properties of this insulating composite, composed by mica tape, epoxy resin (DGEBA), hardener (MHHPA) and zinc naphtenate (N-Zn) as accelerator, were studied. Using thermoananalytical techniques as Differential Scanning Calorimetry (DSC) and Thermogravimetry and Derivative Thermogravimetry (TG/DTG), thermal behavior of each material was evaluated. DSC and TG/DTG curves evidenced chemical interactions between components. The study relative to material curing and cured composite thermal degradation were described. It was clearly observed the N-Zn amount influence in the cure of system, and through DSC curves, it was possible to observe two distinct polymerization coexisting mechanisms, one with lower quantity of N-Zn and another one with bigger concentration, resulting in cure events starting in different temperatures. This fact has not been studied yet since the system has been originated. Besides that, the weight loss related to hardener evaporation starting with curing process was confirmed by composite characterization by FTIR spectra, before and after phenomenon. In practice, two impregnation patterns (Homogeneous and Heterogeneous) of conductive bars are used and a significant difference between them was observed. The developed studies have to be associated to electrical tests to a best understanding about material application and theoretical thermoanalytical properties. In addition, it was performed thermal decomposition of cured composite kinetic study by isothermic and dynamic thermogravimetric methods
|
24 |
Análise térmica aplicada à síntese e caraterização de óxidos mistos de níquel e terras raras / Thermal analysis applied to the synthesis and characterization of mixed oxides of nickel and rare earthAdélia Maria Lima da Silva 15 January 1999 (has links)
Este trabalho apresenta um estudo sistemático sobre síntese, caracterização e análise térmica aplicada a óxidos mistos dos tipos TR2NiO4 [TR = La, Eu e Y (III)] e TRNiO3 [TR = Pr, Nd e Sm (III)]. Os primeiros óxidos foram obtidos a partir da decomposição térmica de acetatos de terras raras e níquel utilizando-se três métodos distintos: (1) mistura mecânica; (2) evaporação do solvente e (3) cristalização com acetona. Os acetatos simples e binários foram caracterizados por análise elementar, espectroscopia de absorção na região do infravermelho, difração de raios X, TG/DTG, DSC e DTA. Os resultados revelaram a formação de sais binários quando utilizaram-se os métodos 2 e/ou 3. Os produtos da decomposição térmica foram basicamente os óxidos individuais e após tratamento térmico obteveram-se os óxidos desejados. Os óxidos TRNiO3 foram preparados através de três métodos diferentes: (1) mistura de óxidos; (2) precipitação simultânea de hidróxidos e (3) processo sol-gel. Estas amostras foram sinterizadas em temperaturas 650 ≤ T ≤ 1000°C e sob pressões de até 70 atm de O2, caracterizadas por difração de raios X, resistividade elétrica, microscopia eletrônica de varredura e calorimetria exploratória diferencial. Os resultados indicaram que o método sol-gel produziu óxidos monofásicos. Os outros dois métodos, mistura de óxidos e hidróxidos, produziram a fase desejada e traços dos óxidos individuais. Desta forma, concluiu-se que a escolha do método a ser utilizado é fundamental para a obtenção do óxido misto desejado. / This work reports a systematic study on the synthesis, characterization and thermal analysis applied of mixed oxides type-TR2NiO4 [TR = La, Eu e Y (III)] e typeTRNiO3 [TR = Pr, Nd e Sm (III)]. The first oxides were prepared through thermal decomposition of rare earth and nickel acetates, which were synthesized by three methods: (1) mechanical mixture; (2) solvent evaporation and (3) crystallization with addition of acetone. The simply and binary acetates were characterized by elementare analyses, infrared spectroscopy, X ray diffraction, TG/DTG, DSC and DTA. The results revealed formation of binary salts when was used the second and/or third methods. The products of thermal decomposition were single oxides, but after thermal treatment were obtained the single phase of materials. The last oxides were prepared through three different methods: (1) mixture of oxides; (2) simultaneous precipitation of hydroxides and (3) sol-gel process. Samples were sintered at temperatures between 650 ≤ T ≤ 1000°C and under oxygen pressures until 70 atm, characterized by X ray diffraction, electrical resistivity, scanning electron microscopy and differential scanning calorimetry. The results revealed that the sol-gel method produced single phase oxides. The other two methods, mixture of oxides and hydroxides, led to have this phase with traces of single oxides. Therefore, it was concluded that the method used is fundamental to get the desired mixed oxides.
|
Page generated in 0.0605 seconds