• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 21
  • 9
  • 3
  • 3
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 40
  • 40
  • 20
  • 20
  • 18
  • 16
  • 11
  • 8
  • 8
  • 7
  • 7
  • 7
  • 6
  • 6
  • 6
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

Detecção de fraturas radiculares verticais em radiografias convencionais e digitais obtidas em três diferentes sistemas na presença e ausência de material intracanal / Detection of vertical root fractures in conventional and digital radiography obtained in three different systems in the presence and absence of intracanal materials

Nascimento, Helena Aguiar Ribeiro do, 1986- 24 August 2018 (has links)
Orientador: Deborah Queiroz de Freitas França / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-24T14:50:35Z (GMT). No. of bitstreams: 1 Nascimento_HelenaAguiarRibeirodo_M.pdf: 1294865 bytes, checksum: aad6a2937765cf9381c0d31a4575d026 (MD5) Previous issue date: 2014 / Resumo: O objetivo no presente estudo foi avaliar a detecção de fraturas radiculares verticais (FRVs) em radiografias convencionais (RCs) e obtidas em três sistemas digitais com diferentes condições intracanal. Foram utilizados 40 dentes humanos unirradiculares com as coroas seccionadas na junção cemento-esmalte. Em seguida, os dentes foram divididos em dois grupos com 20 dentes em cada: grupo controle sem fratura e grupo com FRV. As FRVs foram induzidas em uma máquina de ensaio universal. Após, todos os dentes foram posicionados individualmente no alvéolo de uma secção mandíbula humana seca. Foram obtidas imagens de todos os dentes de acordo com a condição intracanal: sem preenchimento, com guta-percha, com pino metálico e com pino de fibra de vidro. As imagens foram obtidas utilizando-se a técnica do paralelismo e três incidências (orto, mésio e distorradial), com filme convencional (Kodak), placas de armazenamento de fósforo (Digora Optime® e VistaScan®) e um sensor CMOS (SnapShot®). Todas as imagens foram avaliadas por cinco examinadores em uma escala de 5 pontos. Após trinta dias, 25% da amostra foi reavaliada. As reprodutibilidades intra e interexaminador foram avaliadas por meio do Teste Kappa ponderado. Foram calculados os valores de sensibilidade, especificidade, acurácia, valores preditivos positivo e negativo. A comparação das avaliações com o padrão-ouro foi obtida utilizando a área sob a curva ROC, comparadas por meio da análise de variância dois critérios com teste post-hoc de Tukey e nível de significância de 5%. As reprodutibilidades intra e interexaminador exibiram valores de moderado a substancial. Apenas a sensibilidade apresentou diferença significante entre as modalidades de imagem, com valores superiores para o SnapShot (53,3%) e VistaScan (46,0%), seguidos pela RC (41,0%) e Digora (37,5%). Ainda o sistema SnapShot (0,82) apresentou área sob a curva ROC maior que os demais (VistaScan: 0,70; Digora: 0,64; RC: 0,68) na presença do pino de fibra de vidro. Foi possível concluir que todas as modalidades de exame apresentaram um bom desempenho no diagnóstico de FRV na ausência de material intracanal e inferior na presença do pino metálico ou guta-percha. Na condição com pino de fibra de vidro, sistemas digitais com maiores resoluções devem ser preferidos / Abstract: This study aimed to evaluate the detection of vertical root fractures (VRFs) in conventional radiography (CR) and three digital systems in teeth with different intracanal condition. The sample consisted of forty single-rooted human teeth, in which the crowns were sliced at the cementoenamel junction. Then, the teeth were divided equally in two groups: control without fracture and root fracture. The VRFs were induced through a universal testing machine. After this process, all teeth were individually placed in a dry mandible. The images were obtained of all teeth according to the intracanal condition: no filling, gutta-percha, metal and fiberglass post. The images were obtained using the parallelism technique with three different horizontal angulations (ortho, mesial and distorradial) with conventional film (CF) (Kodak), two storage phosphor plates (Digora Optime® and VistaScan®) and one CMOS sensor system (SnapShot®). All images were evaluated by five examiners on a 5-point scale. After thirty days, 25% of the images were re-evaluated. The intra and interobserver reproducibility were calculated using the weighted-kappa test. Values of sensitivity, specificity, accuracy, positive and negative predictive values were calculated. The area under the ROC curve of all modalities in the presence of different intracanal materials was calculated and compared using the two-way analysis of variance (ANOVA) with post-hoc Tukey test and a significance level of 5%. The intra- and interobserver reproducibility values ranged from moderate to substantial. Only the sensitivity showed a significant difference between imaging modalities, with higher values for SnapShot (53,3%) and VistaScan (46,0%), followed by the CR (41,0%) and Digora (37,5%). Also SnapShot (0,82) had an area under the ROC curve greater than the others in the fiberglass post group (VistaScan: 0,70; Digora: 0,64; CR: 0,68). It was concluded that all imaging modalities had a good performance in the diagnosis of VRF in the absence of intracanal materials and lower in the presence of the metal post or gutta-percha. In the fiberglass post group, digital systems with higher resolution should be used / Mestrado / Radiologia Odontologica / Mestra em Radiologia Odontológica
22

Comparison of an intra-oral approach using a contra-angle hand piece with the transbuccal technique for mandibular angle fracture repair

De Waal, Andre Stephanus January 2010 (has links)
Magister Chirurgiae Dentium - MChD / Purpose: To compare the intra-oral approach using a contra-angled hand piece with the standard transbuccal approach in the treatment of mandibular angle fractures. Patients and Methods: Thirty patients with isolated fractures of the mandibular angle were treated by open reduction and internal fixation using one three-dimensional “strut” or “geometric” Synthes® angle plate. Patients were selected randomly for placement of two-millimeter self-threading screws, either through the standard transbuccal technique or with an intra-oral approach using a contra-angle hand piece. None of the patients were placed into post-surgical maxillomandibular fixation (MMF). Swelling and pain were measured pre-operatively and again twenty-four hours after surgery. The actual cutting time from first incision to placement of last suture was documented, as well as the perception of difficulty of the specific case by a single operating surgeon. Results: No statistically significant difference in perception of pain was experienced between the two groups of patients during the first twenty-four hours after surgery. There was also no statistically relevant difference in cutting time between the two placement techniques. A small statistically relevant difference (p-value = 0.089) was found in the amount of swelling post-operatively between the two groups, with more swelling in the control group. Conclusion: The use of a contra-angle hand piece to place screws in the compression band area in a mandible angle fracture is an acceptable alternative to the transbuccal approach. / South Africa
23

Avaliação dos traumatismos dentários atendidos no Serviço de Trauma Dental da Faculdade de Odontologia de Piracicaba = estudo retrospectivo de 10 anos / Evaluation of tooth injuries treated by Dental Trauma Service at Piracicaba Dentistry School : a 10 years retrospective study

Lins, Fernanda Freitas 18 August 2018 (has links)
Orientador: Adriana de Jesus Soares / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-18T14:40:53Z (GMT). No. of bitstreams: 1 Lins_FernandaFreitas_M.pdf: 2426957 bytes, checksum: ff06c275f24b04dd8e054840e6559579 (MD5) Previous issue date: 2011 / Resumo: O propósito do presente estudo restrospectivo foi avaliar os diversos aspectos relacionados às injúrias dentárias traumáticas em relação a sua etiologia, prevalência e classificação, nos pacientes atendidos no Serviço de Trauma Dental da Área de Endodontia da Faculdade de Odontologia de Piracicaba-UNICAMP, no período de Julho de 2000 a Julho de 2010. Os dados obtidos foram tabulados e a análise dos resultados incluiu distribuição de freqüência, teste Qui-quadrado e teste de Mann-Whitney, com nível de significância de 5%. O número total de pacientes foi de 450 (300 do gênero masculino e 150 do gênero feminino) com 1284 dentes traumatizados, representando aproximadamente 2,8 dentes por paciente. Os resultados mostraram que a faixa etária mais prevalente foi de 11 a 15 anos de idade (31,5%) e os fatores etiológicos mais encontrados foram as quedas (35,6%) e os acidentes ciclísticos (26,2%). Os incisivos centrais superiores foram os dentes com maior percentual de trauma (53,7%). O tipo de injúria aos tecidos dentários mais prevalente foi a fratura de esmalte e dentina, enquanto as avulsões e as subluxações foram os tipos de injúrias aos tecidos de suporte mais frequentes. O mês e o dia em que mais ocorreram os traumas foi o mês de Maio e aos Sábados. O gênero exerceu influência em relação a etiologia do trauma (p < 0,05/ Teste Qui-quadrado) e não obteve diferença significativa com as diferentes faixas etárias (p > 0,05 / Teste Mann Whitney). Concluiu-se que o gênero masculino, a faixa etária de 11 a 15 anos, as quedas, os incisivos centrais superiores, as fraturas de esmalte e dentina e as avulsões foram os achados mais freqüentes / Abstract: The purpose of this retrospective study was to evaluate several aspects related to traumatic dental injuries regarding its etiology, prevalence and classification in the patients of Service of Dental Trauma of the Endodontics Area, Faculty of Dentistry of Piracicaba-UNICAMP, from July 2000 to July 2010. The statistical treatment analysed data from frequency distribution, Chi-square test and Mann-Whitney test. The level of significance was set at 5% for all analyses. A total of 450 patients (150 females and 300 males) with 1284 injured teeth, approximately 2,8 per patient. The results showed that the prevalent age group was 11 to 15 years (31.5%) and the most frequent etiological factors of tooth injuries were falls (35.6%) and bicycle accidents (26.2%). The upper central incisors were the teeth with higher percentage of trauma (53.7%). The most prevalent type of injury to dental tissue was fracture of enamel and dentin, while avulsions and subluxations were the most frequently types of injuries to the supporting tissues. The month and day that most occurred dental injuries was May and Saturday respectively. Gender exerted influence over the etiology of trauma (p <0.05 / Chi?square) and had no significant difference with the different age groups (p> 0.05 / Mann Whitney). It was concluded that male gender, age range 11 to 15 years, falls, upper central incisors, the enamel and dentin fractures and avulsions were the most frequently findings / Mestrado / Endodontia / Mestre em Clínica Odontológica
24

Influência do uso da ferramenta de redução do artefato no diagnóstico de fraturas radiculares verticais em exames de tomografia computadorizada de feixe cônico : estudo in vitro / Influence of an artifact reduction tool on the diagnosis of vertical root fractures in teeth with metal posts

Bezerra, Ilana Sanamaika Queiroga, 1984- 26 August 2018 (has links)
Orientadores: Deborah Queiroz de Freitas França, Gláucia Maria Bovi Ambrosano / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-26T13:33:44Z (GMT). No. of bitstreams: 1 Bezerra_IlanaSanamaikaQueiroga_D.pdf: 1698292 bytes, checksum: 997da55ad95075c898e9eae4519d6525 (MD5) Previous issue date: 2014 / Resumo: O objetivo neste trabalho foi verificar a influência da ferramenta para redução de artefato (FRA) na qualidade da imagem e no diagnóstico de FRVs, em dentes com pino metálico intracanal. A amostra foi composta por trinta dentes unirradiculares, que tiveram suas coroas removidas e seus canais instrumentados. Do total, foram induzidas fraturas completas e incompletas em vinte raízes e ao final, todas as raízes foram divididas em três grupos: controle (n=10), fratura radicular completa (n=10) e fratura radicular incompleta (n=10). Cada raiz recebeu um pino metálico intracanal e foi escaneada duas vezes no tomógrafo Picasso Trio 3D® (Vatech, Hwaseong, Coreia do Sul): uma sem e uma com o emprego da FRA. As imagens foram avaliadas objetiva e subjetivamente. A avaliação objetiva foi feita no ImageJ (NIH, Bethesda, MD, EUA), em uma região de interesse circular padronizada, na qual foram mensuradas os valores médios e a variação dos tons de cinza e a taxa contraste-ruído (TCR) nas imagens com e sema FRA. A avaliação subjetiva foi realizada de duas formas: inicialmente, cinco avaliadores (cirurgiões-dentistas, especialistas em Radiologia Odontológica) treinados analisaram as imagens no software EZ3D quanto à presença de FRV, utilizando uma escala de cinco pontos: Posteriormente, um avaliador quantificou os artefatos formados. Foram avaliados o cupping, as bandas hipodensas e as estrias hiperdensas. A imagem obtida com FRA foi comparada à sua respectiva sem FRA para atribuição de um dos três escores: (0) não houve mudança na quantidade de artefato formado; (1) houve diminuição e (2) houve aumento. As concordâncias intra e interexaminador foram avaliadas pelo teste Kappa ponderado. A comparação dos resultados do diagnóstico de FRV com o padrão-ouro foi realizada pela curva ROC (Receive Operating Characteristic). Além disso, também foram calculados os valores de sensibilidade, especificidade e acurácia. A comparação dos resultados da análise objetiva, dos valores das áreas sob a curva ROC e dos testes de diagnóstico nas aquisições com e sem a FRA foi realizada por meio do Teste t. A presença de artefatos foi avaliada por análise descritiva. Os resultados mostraram diminuição significativa dos valores médios dos tons de cinza (p=0,002) e da TCR (p=0,000) com utilização da FRA. Quanto à avaliação subjetiva, os valores das áreas sob a curva ROC, sensibilidade, especificidade e acurácia também foram inferiores com a utilização da FRA, sendo os dois últimos estatisticamente significativos, para os casos de fratura incompleta (p=0,028 e p=0,037, respectivamente) e fratura completa (p=0,021 e p=0,031, respectivamente). Em relação aos artefatos avaliados, de uma maneira geral houve diminuição dos mesmos nas imagens com FRA. Dessa forma, concluiu-se que a utilização da FRA causou uma diminuição nos artefatos formados, porém não houve não houve melhora na qualidade da imagem avaliada de maneira objetiva nem repercussão no diagnóstico de FRVs em raízes com pino metálico intracanal, uma vez que o mesmo foi prejudicado / Abstract: This study aimed to verify the influence of the artifact reduction algorithm in the image quality and the diagnosis of VFR. The sample was composed of thirty single-rooted teeth, which the crown was removed and the root canal was prepared. In twenty roots, fractures were induced. The roots were divided into three groups: control (n=10), complete (n=10) and incomplete (n=10) VRF. In each root canal it was inserted a well-fitted metal post and it was scanned in the Picasso Trio 3D® CBCT device (Vatech, Hwaseong, South Korea) with and without the artifact reduction algorithm. The images were evaluated objective- and subjectively. The objective evaluation was performed in the ImageJ software (NIH, Bethesda, MD, USA), by a standard round region of interest, on which it was measured the mean value of the grey level and contrast-to-noise ratio (CNR). Five observers (oral radiologists) performed blindly the subjective evaluation in EZ3D software to diagnosis VRF, which was classified according to a 5-point scale. Posteriorly, one observer quantified the presence of the beam hardening artifacts. It was evaluated the cupping artifacts, hypodense halos and streak artifacts. The images with and without the artifact reduction algorithm was compared according three scores: no change, increase or decrease of the beam hardening artifact. The intra- and interobserver agreement were calculated by the weighted-Kappa test. The ROC (Receiver Operating Characteristic) curve was used to compare the diagnosis of VRF and the gold standard. Also, the sensitivity, specificity and accuracy were obtained. The comparison of the grey levels and the CNR were performed by the t-Test. The production of beam hardening artifacts was descriptive analyzed. The results showed a significant decrease of the grey level (p=0,002) and CNR (p=0,000) with the artifact reduction algorithm. The ROC curve values, sensitivity, specificity and accuracy were lower with the artifact reduction algorithm for the diagnosis of VRF. It was observed a statistically significant difference in the specificity and accuracy. Regarding to the quantity of the beam hardening artifacts, it was observed an overall reduction in images with the artifact reduction algorithm. In conclusion, the use of the artifact reduction algorithm produced a decrease of the beam hardening artifacts; however, it was observed negative influence in image quality and in the diagnosis of VRF in the presence of metal post / Doutorado / Radiologia Odontologica / Doutora em Radiologia Odontológica
25

Avaliação da resistência à fratura vertical de dentes tratados endodonticamente com diferentes materiais obturadores / Vertical fracture resistance of endodontically treated teeth with different root filling materials

Garcia, Liliani Fernanda Marques 16 October 2009 (has links)
O presente estudo teve como objetivo avaliar comparativamente in vitro a resistência à fratura radicular de dentes tratados endodonticamente usando diferentes materiais obturadores: AH Plus (Dentsply/De Trey, Alemanha), Real Seal (Sybron Endo, EUA), GuttaFlow (Coltène/Whaledent, Suíça) , ActiV GP (Brasseler, EUA) e Thermafil (Dentsply-Tulsa Dental, EUA). Sessenta e quatro pré-molares inferiores foram divididos em Grupo Controle (n=4), onde as raízes não foram nem instrumentadas nem obturadas e outros 5 grupos de acordo com os materiais obturadores empregados: Grupo AH Plus (n=12); Grupo Real Seal (n=12); Grupo GuttaFlow (n=12); Grupo ActiV GP (n=12); Grupo Thermafil (n=12). As raízes foram instrumentadas com o sistema Protaper Universal (Dentsply-Maillefer, Suíça), e em seguida foram obturadas com os respectivos materiais. Após a obturação, todos os espécimes foram armazenados à 37º C com 100% de umidade por 72 horas e incluídos em resina acrílica. O ligamento periodontal foi simulado com Impregum, que formou uma fina camada entre a raiz e a resina acrílica. Os espécimes foram submetidos ao teste de resistência à fratura em uma máquina de ensaios triaxiais (1,0mm/min). Os valores médios obtidos e o desvio padrão (em Newtons) em ordem decrescente foram: Grupo controle 394,25 ± 56,17 N; Grupo ActiV GP 263 ± 89,32 N; Grupo Thermafil 198,17 ± 61,65 N; Grupo AH Plus 158,08 ± 31,56 N; Grupo Real Seal 154,92 ± 42,64 N e Grupo GuttaFlow 107,92 ± 20,72 N. Os dados foram submetidos aos testes ANOVA e Dunett (5%). Dentre os grupos experimentais, as raízes obturadas com ActiV GP mostraram-se mais resistentes à força vertical aplicada, porém similares aos grupos controle e Thermafil. Os grupos AH Plus, Real Seal e Thermafil mostraram-se similares estatisticamente quanto à resistência à fratura. O grupo GuttaFlow apresentou menores valores médios de resistência à fratura. / The aim of this study was to evaluate the in vitro vertical fracture resistance of endodontically treated teeth using different root filling materials: AH Plus (Dentsply/De Trey, Alemanha), Real Seal (Sybron Endo, EUA), GuttaFlow (Coltène/Whaledent, Suíça) , ActiV GP (Brasseler, EUA) and Thermafil (Dentsply- Tulsa Dental, EUA). Sixty four single-rooted human lower premolar were assigned into a Control Group (n=4), where the roots were not prepared or filled, and five experimental groups (n=12) according to the root filling materials: Group AH Plus; Group Real Seal; Group GuttaFlow; Group ActiV GP; Group Thermafil. The roots were prepared using Protaper Universal system (Dentsply-Maillefer, Suíça) and filled using one of the root filling materials. Then, the specimens were stored at 37º C at 100% humidity for 72 hours and included in acrylic resin. The periodontal ligament was simulated by the use of Impregum, which made a thin layer between the root and acrylic resin. The specimens were submitted to a vertical fracture resistance using a testing machine triaxiais (1,0mm/min). The values (Newton) and standard deviations obtained were: Control Group 394,25 ± 56,17N; Group ActiV GP 263 ± 89,32N; Group Thermafil 198,17 ± 61,65N; Group AH Plus 158,08 ± 31,56N; Group Real Seal 154,92 ± 42,64N and Group GuttaFlow 107,92 ± 20,72N. The data were submitted to ANOVA e Dunett tests (5%). Among the experimental groups, roots filled with ActiV GP showed the highest values of resistance of load vertical was applied, and were similar to Control Group and Thermafil. AH Plus, Real Seal and Thermafil groups showed statistical similar fracture resistance. GuttaFlow Group showed the lowest values of fracture resistance.
26

Estudo in vitro da perfuração radicular por diferentes diâmetros de mini-implantes / In vitro study of root perforation by different mini-implant diameters

Roberto Bombonatti 07 November 2014 (has links)
Este trabalho teve como objetivo avaliar o torque e a carga axial de inserção e a severidade das lesões radiculares em dentes humanos decorrentes da utilização de diferentes diâmetros de mini-implantes com finalidade ortodôntica. Sessenta pré-molares extraídos foram inclusos em osso artificial e divididos em 3 grupos, correspondentes a 3 diferentes diâmetros de mini-implante (1,4mm, 1,6mm e 1,8mm). Em cada raiz dentária foram inseridos manualmente 2 mini-implantes autoperfurantes utilizando dois métodos de inserção (com e sem perfuração prévia inicial com fresa) e em duas alturas (apical e cervical). Quinze mini-implantes foram inseridos apenas em osso artificial como parâmetro de comparação. Foram quantificados o torque e a carga axial de inserção através de um torquímetro axial digital e uma célula de carga respectivamente. Os dentes foram, então, escaneados e analisados através de microtomografia computadorizada (Micro-CT) a fim de se observar as severidades das lesões radiculares provocadas pelos mini-implantes. Os dados referentes ao torque e à carga axial dos mini-implantes inseridos em pré-molares foram submetidos à análise de variância (ANOVA) a três critérios, sendo aplicados posteriormente testes de Tukey para comparação entre os grupos. A diferença dos torques e das cargas axiais entre os mini-implantes inseridos no osso artificial e nas raízes dentárias foi estimada por testes t. Foram aplicados também testes de Qui-Quadrado para avaliar as severidades das lesões radiculares. Tanto os torques como as cargas axiais de inserção dos mini-implantes inseridos em raízes de dentes humanos apresentaram diferenças estatisticamente significantes entre os diferentes diâmetros avaliados, porém sem um padrão definido. Os miniimplantes inseridos nas raízes apresentaram valores maiores estatisticamente significantes do que os inseridos em osso artificial somente em relação à carga axial. As lesões radiculares de dentes humanos decorrentes dos mini-implantes se tornaram mais severas estatisticamente com a perfuração prévia inicial ao procedimento de inserção. / The aim of this study was to evaluate placement torque, axial placement load and severity of root lesions in human teeth caused by different diameters of orthodontic mini-implants. Sixty extracted premolars were included in artificial bone and divided into three groups according to different mini-implant diameters (1.4mm, 1.6mm and 1.8mm). Two self-drilling mini-implants were manually inserted into each root using two placement methods (with and without initial pre-drilling) in the apical and cervical regions. Fifteen mini-implants were inserted into artificial bone as a comparison parameter. Placement torque and axial placement load were quantified by a digital torquimeter and a load cell, respectively. The teeth were scanned and analyzed with microcomputed tomography (Micro-CT) to observe the severity of root lesions caused by the mini-implants. The torque and the axial load of mini-implants inserted into premolars were analyzed by 3-way analysis of variance (ANOVA), followed by Tukey tests. Differences in the torques and axial loads between the mini-implants inserted in dental roots and artificial bone were compared with t tests. Chi-square tests were applied to assess the severity of root lesions. The placement torques and the axial placement loads of mini-implants inserted into human dental roots showed significant differences between the different diameters evaluated, but with no standardized effect. Mini-implants inserted into the roots showed significantly higher axial placement load values than those inserted into artificial bone. The root lesions of human teeth caused by mini-implants became statistically more severe with initial pre-drilling.
27

Estudo in vitro da perfuração radicular por diferentes diâmetros de mini-implantes / In vitro study of root perforation by different mini-implant diameters

Bombonatti, Roberto 07 November 2014 (has links)
Este trabalho teve como objetivo avaliar o torque e a carga axial de inserção e a severidade das lesões radiculares em dentes humanos decorrentes da utilização de diferentes diâmetros de mini-implantes com finalidade ortodôntica. Sessenta pré-molares extraídos foram inclusos em osso artificial e divididos em 3 grupos, correspondentes a 3 diferentes diâmetros de mini-implante (1,4mm, 1,6mm e 1,8mm). Em cada raiz dentária foram inseridos manualmente 2 mini-implantes autoperfurantes utilizando dois métodos de inserção (com e sem perfuração prévia inicial com fresa) e em duas alturas (apical e cervical). Quinze mini-implantes foram inseridos apenas em osso artificial como parâmetro de comparação. Foram quantificados o torque e a carga axial de inserção através de um torquímetro axial digital e uma célula de carga respectivamente. Os dentes foram, então, escaneados e analisados através de microtomografia computadorizada (Micro-CT) a fim de se observar as severidades das lesões radiculares provocadas pelos mini-implantes. Os dados referentes ao torque e à carga axial dos mini-implantes inseridos em pré-molares foram submetidos à análise de variância (ANOVA) a três critérios, sendo aplicados posteriormente testes de Tukey para comparação entre os grupos. A diferença dos torques e das cargas axiais entre os mini-implantes inseridos no osso artificial e nas raízes dentárias foi estimada por testes t. Foram aplicados também testes de Qui-Quadrado para avaliar as severidades das lesões radiculares. Tanto os torques como as cargas axiais de inserção dos mini-implantes inseridos em raízes de dentes humanos apresentaram diferenças estatisticamente significantes entre os diferentes diâmetros avaliados, porém sem um padrão definido. Os miniimplantes inseridos nas raízes apresentaram valores maiores estatisticamente significantes do que os inseridos em osso artificial somente em relação à carga axial. As lesões radiculares de dentes humanos decorrentes dos mini-implantes se tornaram mais severas estatisticamente com a perfuração prévia inicial ao procedimento de inserção. / The aim of this study was to evaluate placement torque, axial placement load and severity of root lesions in human teeth caused by different diameters of orthodontic mini-implants. Sixty extracted premolars were included in artificial bone and divided into three groups according to different mini-implant diameters (1.4mm, 1.6mm and 1.8mm). Two self-drilling mini-implants were manually inserted into each root using two placement methods (with and without initial pre-drilling) in the apical and cervical regions. Fifteen mini-implants were inserted into artificial bone as a comparison parameter. Placement torque and axial placement load were quantified by a digital torquimeter and a load cell, respectively. The teeth were scanned and analyzed with microcomputed tomography (Micro-CT) to observe the severity of root lesions caused by the mini-implants. The torque and the axial load of mini-implants inserted into premolars were analyzed by 3-way analysis of variance (ANOVA), followed by Tukey tests. Differences in the torques and axial loads between the mini-implants inserted in dental roots and artificial bone were compared with t tests. Chi-square tests were applied to assess the severity of root lesions. The placement torques and the axial placement loads of mini-implants inserted into human dental roots showed significant differences between the different diameters evaluated, but with no standardized effect. Mini-implants inserted into the roots showed significantly higher axial placement load values than those inserted into artificial bone. The root lesions of human teeth caused by mini-implants became statistically more severe with initial pre-drilling.
28

Influência da miliamperagem sobre a qualidade do diagnóstico das fraturas radiculares por meio de tomografia computadorizada de feixe cônico: estudo in vitro / Influence of milliamperage on the diagnostic quality of root fractures using cone-beam computed tomography: in vitro study

Meira, Ricardo Manoel Tângari de Araújo e [UNESP] 28 April 2016 (has links)
Submitted by RICARDO MANOEL TÂNGARI DE ARAÚJO E MEIRA null (tangarimeira@gmail.com) on 2016-06-07T21:20:56Z No. of bitstreams: 1 Dissertação.pdf: 1713062 bytes, checksum: dea4b5a0cb16097137546acd6f9efe5e (MD5) / Approved for entry into archive by Ana Paula Grisoto (grisotoana@reitoria.unesp.br) on 2016-06-08T18:32:21Z (GMT) No. of bitstreams: 1 meira_rmta_me_arafo.pdf: 1713062 bytes, checksum: dea4b5a0cb16097137546acd6f9efe5e (MD5) / Made available in DSpace on 2016-06-08T18:32:21Z (GMT). No. of bitstreams: 1 meira_rmta_me_arafo.pdf: 1713062 bytes, checksum: dea4b5a0cb16097137546acd6f9efe5e (MD5) Previous issue date: 2016-04-28 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O objetivo deste trabalho foi avaliar a influência da miliamperagem (mA) sobre a qualidade do diagnóstico das fraturas radiculares por meio de TCFC. Foram selecionados 58 dentes anteriores e posteriores extraídos de humanos, sendo que todos tiveram os condutos radiculares preparados e, metade destes, foram obturados. Os dentes foram distribuídos em dois grupos (n=29): controle (GC) e fraturado (GF). Fraturas radiculares nos dentes anteriores e posteriores foram induzidas em uma máquina universal de ensaios mecânicos e, posteriormente, os dentes foram inseridos em um crânio macerado adulto de humano composto por maxila e mandíbula. Em seguida, o volume de imagem de cada dente foi adquirido no aparelho de TCFC (Scanora 3Dx), utilizando-se cinco diferentes protocolos de miliamperagem (4; 5; 6,3; 8 e 10 mA). As imagens foram aleatorizadas e avaliadas por dois especialistas em Radiologia Odontológica e Imaginologia, que as classificaram quanto a presença ou ausência de fraturas, seguindo uma escala de confiança de cinco pontos. A concordância intra e interexaminador foi estimada por meio da estatística Kappa com ponderação linear. O desempenho do diagnóstico foi determinado pela área sob a curva ROC (AUROC) por ponto e por intervalo de 95% de confiança (IC95%), sendo adotado nível de significância de 5%. As reprodutibilidades intra e interexaminador indicaram concordâncias substancial e moderada, respectivamente. Observou-se que todos os protocolos de mA tiveram capacidade de diagnóstico (p<0,0001). A AUROC foi significativamente maior com os protocolos de 8 e 10 mA (p≤0,0389) e, consequentemente, promoveram uma melhor eficácia de diagnóstico. Pôde-se concluir que a miliamperagem exerce uma influência significativa sobre a qualidade do diagnóstico das fraturas radiculares em imagens de TCFC. A sua redução é possível e deve ser realizada com cautela, a fim de que não haja prejuízo para a eficácia de diagnóstico dessa condição. / The aim of this study was to assess the influence of mA on diagnostic quality of RF in CBCT imaging. Fifty-eight (58) anterior and posterior human teeth were selected, in which all had their root canals prepared and half of them were endodontically filled. The teeth were divided into two groups (n=29): control (CG) and fractured (FG). A universal testing machine induced RF(s) on anterior and posterior teeth. Prior to the image acquisition, these teeth were inserted in the upper and lower empty alveolar sockets of an adult dried skull (phantom). Then, the imaging volume of each tooth was acquired in the Scanora 3DX machine, using five different protocols of mA(s): 4; 5; 6.3; 8 and 10. Two oral radiologists, independently and blind to the identification of the samples, interpreted the randomized images. On suspicion of the presence/absence of root fractures, they were interpreted using a five points confidence scale. The intra and interexaminer agreement was estimated by the Kappa statistic with linear weighting. The diagnostic performance was determined by the area under the ROC curve (AUROC) by point and by 95% confidence interval (95% CI), being adopted the significance level of 5%. The intra and interexaminer reproducibility indicated calibration substantial and moderate, respectively. It was observed that all protocols of mA have diagnostic capability (p <0.0001). The AUROC was significantly higher with the protocols 8 and 10 mA (p≤0,0389) and, consequently, they had better diagnostic efficacy. It was concluded that the mA has a significant influence on the quality of diagnosis of root fractures in CBCT images. The reduction is possible and should be performed with caution, so that there is no damage to the efficacy of diagnosis of this condition.
29

Influência da miliamperagem sobre a qualidade do diagnóstico das fraturas radiculares por meio de tomografia computadorizada de feixe cônico : estudo in vitro /

Meira, Ricardo Manoel Tângari de Araújo. January 2016 (has links)
Orientador: Guilherme Monteiro Tosoni / Banca: Andréa Gonçalves / Banca: Matheus Lima de Oliveira / Resumo: O objetivo deste trabalho foi avaliar a influência da miliamperagem (mA) sobre a qualidade do diagnóstico das fraturas radiculares por meio de TCFC. Foram selecionados 58 dentes anteriores e posteriores extraídos de humanos, sendo que todos tiveram os condutos radiculares preparados e, metade destes, foram obturados. Os dentes foram distribuídos em dois grupos (n=29): controle (GC) e fraturado (GF). Fraturas radiculares nos dentes anteriores e posteriores foram induzidas em uma máquina universal de ensaios mecânicos e, posteriormente, os dentes foram inseridos em um crânio macerado adulto de humano composto por maxila e mandíbula. Em seguida, o volume de imagem de cada dente foi adquirido no aparelho de TCFC (Scanora 3Dx), utilizando-se cinco diferentes protocolos de miliamperagem (4; 5; 6,3; 8 e 10 mA). As imagens foram aleatorizadas e avaliadas por dois especialistas em Radiologia Odontológica e Imaginologia, que as classificaram quanto a presença ou ausência de fraturas, seguindo uma escala de confiança de cinco pontos. A concordância intra e interexaminador foi estimada por meio da estatística Kappa com ponderação linear. O desempenho do diagnóstico foi determinado pela área sob a curva ROC (AUROC) por ponto e por intervalo de 95% de confiança (IC95%), sendo adotado nível de significância de 5%. As reprodutibilidades intra e interexaminador indicaram concordâncias substancial e moderada, respectivamente. Observou-se que todos os protocolos de mA tiveram capacidade de diag... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The aim of this study was to assess the influence of mA on diagnostic quality of RF in CBCT imaging. Fifty-eight (58) anterior and posterior human teeth were selected, in which all had their root canals prepared and half of them were endodontically filled. The teeth were divided into two groups (n=29): control (CG) and fractured (FG). A universal testing machine induced RF(s) on anterior and posterior teeth. Prior to the image acquisition, these teeth were inserted in the upper and lower empty alveolar sockets of an adult dried skull (phantom). Then, the imaging volume of each tooth was acquired in the Scanora 3DX machine, using five different protocols of mA(s): 4; 5; 6.3; 8 and 10. Two oral radiologists, independently and blind to the identification of the samples, interpreted the randomized images. On suspicion of the presence/absence of root fractures, they were interpreted using a five points confidence scale. The intra and interexaminer agreement was estimated by the Kappa statistic with linear weighting. The diagnostic performance was determined by the area under the ROC curve (AUROC) by point and by 95% confidence interval (95% CI), being adopted the significance level of 5%. The intra and interexaminer reproducibility indicated calibration substantial and moderate, respectively. It was observed that all protocols of mA have diagnostic capability (p <0.0001). The AUROC was significantly higher with the protocols 8 and 10 mA (p≤0,0389) and, consequently, they had bette... (Complete abstract click electronic access below) / Mestre
30

Avaliação das propriedades mecânicas e químicas em função de diferentes cimentos resinosos e pinos não-metálicos /

Bandéca, Matheus Coelho. January 2009 (has links)
Resumo: Este estudo objetivou: (1) testar a hipótese que a utilização de pinos nãometálicos em dentes tratados endodonticamente está associado a longevidade da restauração através de uma revisão sistemática; (2) avaliar o grau de conversão de dois cimentos resinosos em diferentes tempos após a fotoativação; (3) avaliar a resistência adesiva de diferentes cimentos resinosos usando dois pinos não-metálicos; (4) e avaliar a resistência a fratura e padrão de falha de dentes submetidos ao clareamento dental interno usando peróxido de hidrogênio a 35% restaurados com diferentes procedimentos. No artigo 1, 157 artigos participaram do estudo e após os critérios de inclusão-exclusão, restaram apenas 5 artigos. Para o artigo 2, vinte espécimes foram confeccionados para cada cimento, Panavia® F2.0 e RelyXTM Unicem Applicap. Cada espécime foi curado com luz LED e foram analisados imediatamente, 24 horas, 48 horas e 7 dias após a fotoativação. Os testes usados foram grau de conversão (FT-IR) e termogravimetria. No artigo 3, oitenta dentes pré-molares unirradiculares livres de coroas foram usados e divididos em 8 grupos: os pinos Exacto! e Everstick! foram cimentados com Breeze!, Nexus! 3, Panavia! e Bistite!. Os dentes foram obturados e preparados para cimentação dos pinos não-metálicos. Cada espécime foi perpendicularmente seccionado em aproximadamente 1 mm de espessura em 6 discos e divididos em região ! cervical, médio e apical. No artigo 4, oitenta dentes incisivos inferiores foram usados e metade foram clareados. Os dentes foram restaurados com resina composta, pinos de resina reforçado com fibra e pinos de fibra de vidro. Os pinos foram cimentados com Breeze! e Panavia!. Os espécimes foram submetidos ao teste de resistência a fratura pela máquina de testes universal. Todos os dados foram submetidos ao devido tratamento estatístico. Os pinos usados... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: This study aimed: (1) To test the hypothesis that the placement of nonmetallic post in endodontically treated teeth is associated with improved survival rate of the restored teeth althouth systematic review; (2) to evaluate the degree of conversion of two resin cements in differents times after light-activated; (3) to evaluate the microtensile bond strength of different resin cement systems using two nonmetallic posts; (4) to evaluate the fracture resistance and failure pattern of endodontically treated teeth after intracoronal bleaching using 35% hydrogen peroxide with different restorative procedures. For the article 1, 157 papers were used and after the inclusion-exclusion procedure, only 5 papers remained. For the article 2, twenty specimens were made for each cement, Panavia® F2.0 and RelyXTM Unicem Applicap. Each specimen were cured with LED and were tested immediately, 24 hours, 48 hours and 7 days after light-activated. The tests used were degree of conversion (FT-IR) and thermogravimetric. For the article 3, eighty single-rooted human mandibular first premolar free crown were used and divided into 8 groups: Exacto! and Everstick! posts were cemented with Breeze!, Nexus! 3, Panavia! F 2.0 and Bistite! II DC. The teeth were obtured and prepared for cementation of the nonmetallic posts. Each specimen were perpendicularly sectioned into approximately 1 mm thick sections resulting in 6 serial slices and divided in cervical, meddium and apical region. For the !article 4, eighty mandibular incisors were used and the half teeth were bleached. The teeth were restored with composite resin, fiber-reinforced composite post and glass fiber post. The posts were cemented with Breeze! and Panavia!. The specimens were submitted to the fracture resistance test by universal test machine. Statistical analyses were performed for each article. The posts used... (Complete abstract click electronic access below) / Orientador: Sizenando de Toledo Porto Neto / Coorientador: Omar El-Mowafy / Coorientador: Alessandra Nara de Souza Rastelli / Banca: Roberto Cury Saad / Banca: Darlon Martins Lima / Mestre

Page generated in 0.0989 seconds