201 |
Utilização de biodiesel animal em turbinas a gás /Silva, Ramon Eduardo Pereira. January 2009 (has links)
Resumo: Estudos têm sido realizados em relação à utilização de biodiesel em motores alternativos de ciclo Diesel, porém pouco material é encontrado quando se utiliza este combustível em turbinas a gás. Este trabalho analisou os parâmetros de desempenho e emissões de poluentes para várias misturas de biodiesel/querosene de aviação em um turboeixo Rover 1/S60. Os testes mostraram que não houve alterações significativas na operação do turboeixo. O estudo mostrou, também, que houve decréscimo de eficiência térmica e aumento de consumo de combustível com a utilização de misturas mais ricas em biodiesel. As emissões de poluentes também decresceram com o aumento de teor de biodiesel na mistura. / Abstract: Several tests have been performed comparing diesel and several kinds of esthers (biodiesel), most in reciprocating engines but also in micro-gas-turbines. This work studies a stationary turboshaft Rover 1/S60 performance and pollution emissions in the utilization of several blends of aviation kerosene and biodiesel. The tests also show that no significative changes occurred in turboshaft operation. This study also shows an increase of fuel consumption and a decrease in thermal efficiency and a decrease of pollutant species emission as the higher biodiesel proportion at blends are used at turboshaft operation. / Orientador: João Andrade de Carvalho Junior / Coorientador: Pedro Teixeira Lacava / Banca: Petronio Masanobu Tanisho / Banca: Luiz Daré Neto / Mestre
|
202 |
Diseño e implementación de un sistema supervisor con modelos basados en similitud para la detección y aislamiento de fallas en turbina a gas naturalFuentealba Toro, Sebastián Felipe January 2012 (has links)
Ingeniero Civil Electricista / Debido al constante aumento en los estándares de producción y calidad, así como las exigencias impuestas por estrictas normativas ambientales y de seguridad, existe en la industria moderna la necesidad de incrementar la eficiencia y complejidad de los sistemas de control asociados. Sin embargo, existen perturbaciones que no pueden ser eficazmente manejadas por los controladores a menos que exista una adecuada caracterización del modo de operación. He ahí la necesidad de incorporar sistemas de monitoreo para detección y aislamiento de anomalías que pudiesen condicionar el funcionamiento del proceso.
En este sentido, el objetivo general de este trabajo es diseñar e implementar un sistema supervisor en línea con modelos basados en similitud (SBM) que permita la detección y el aislamiento de anomalías en procesos industriales multivariados y en particular, en el caso de una turbina a gas natural. El diseño del sistema supervisor incluye una etapa preliminar fuera de línea y de tres etapas que operan en tiempo real. La etapa preliminar corresponde al análisis del proceso en estudio y de los modos de falla de interés, así como la generación de los modelos SBM que serán utilizados en la etapa de implementación en línea. A través de esta metodología de estudio de eventos se determinan las variables más relevantes en cada anomalía con el fin de optimizar el procedimiento de generación de modelos. Las etapas asociadas a la implementación en línea se han denominado fases . Fase I genera una señal de alarma si la salida estimada por un modelo clasificador SBM, diseñado en la etapa preliminar, supera un umbral determinado en la etapa preliminar. Si se produce una alarma, entonces se ejecuta la Fase II que determina el vector de residuos entre las salidas medidas y las salidas estimadas por el modelo SBM, para cada posible anomalía en gestación. Fase III calcula el indicador de Hotelling de cada vector de residuos. Se genera una alarma de anomalía si este indicador supera un umbral determinado en la etapa preliminar.
Este sistema es aplicado en una turbina a gas natural para el estudio de dos anomalías que ocasionan una disminución significativa en la potencia: (i) temperatura de un álabe fuera de rango (Anomalía #1) y, (ii) suciedad excesiva en el compresor (Anomalía #2). Los porcentajes de detección de las Anomalías #1 y #2 son 96% y 76%, respectivamente. Estos porcentajes se estiman en función del número de datos. Debido al tamaño de los conjuntos de datos disponibles, es imposible en esta aplicación utilizar probabilidades para caracterizar al sistema supervisor. Las principales ventajas de disponer de este sistema supervisor son: (1) con una metodología de estudio de eventos, se obtienen aquellas variables que son más relevantes en cada anomalía, (2) con la Fase I se logran descartar del análisis aquellas observaciones que representan un modo normal de operación y (3) a través de señales binarias Normal o Alarma se logra centralizar la información que entregan todos los modelos.
|
203 |
Thermodynamic, economic and emissions analysis of a micro gas turbine cogeneration system operating on biofuels /Kunte, Benjamin. January 2015 (has links)
Orientador: José Alexandre Matelli / Coorientador: José Luz Silveira / Banca: Celso Eduardo Tuna / Banca: Pedro Lacava / Resumo: Os métodos mais promissores para reduzir gases de efeito estufa, bem como combater o iminente esgotamento das reservas de energia fóssil, são: a) o uso de combustíveis alternativos obtidos a partir da biomassa, como o biogás ou gás de síntese (syngas); b) o aumento da eficiência do sistema através da redução da percentagem de energia útil perdido para o ambiente. Enquanto a otimização da eficiência de uma determinada máquina da central elétrica, por exemplo, turbina a gás ou compressor, é um desenvolvimento muito demorado, a cogeração pode rápida e significativamente aumentar a eficiência global da central. Neste trabalho, análise termodinâmica, econômica e de emissões de um sistema de cogeração baseado em uma microturbina a gás de 200 kW combinado com uma caldeira de recuperação são conduzidas. Além disso, a operação de biogás e syngas é comparada com a operação de gás natural para investigar a pertinência destes dois combustíveis alternativos para o uso em micro turbinas a gás. A central de cogeração proposta mostrou-se tecnicamente viável para todos os combustíveis, porque a microturbina selecionada é disponível em várias versões, específicas para cada combustível, com sistemas de injeção de combustível otimizados. A central apresentou eficiências energéticas globais de 50,9%, 48,6% e 47,9% para operação com gás natural, biogás e syngas, respectivamente. Devido aos preços muito elevados do gás natural e do syngas, a central de cogeração apresentou viabilidade econômica apenas no caso de operação com biogás, com curtos períodos de retorno de aproximadamente 2,8 anos e alta economia anual esperada. Além disso, o biogás tem a maior eficiência ecológica e, portanto, apresentou-se como a melhor alternativa aos combustíveis fósseis / Abstract: The most promising methods to reduce greenhouse gases as well as counteract against the imminent depletion of fossil fuels are: a) the use of alternative fuels obtained from biomass, such as biogas or bio-syngas; b) enhancing the power plant efficiency by decreasing the percentage of useful energy lost to the environment. Whereas efficiency optimisation of a particular machine in a power plant, e.g. gas turbine or compressor, is a very longsome development, cogeneration can quickly and significantly increase the overall efficiency of a power plant. In this work, energetic, exergetic, emissions and economic analyses of a cogeneration system consisting of a 200 kW micro gas turbine combined with a heat recovery steam generator are introduced and conducted. Furthermore, biogas and syngas operation are compared to natural gas operation, to investigate the adequacy of these two alternative fuels for use in micro gas turbines. The proposed cogeneration plant proved to be technically feasible for all fuels, because the selected micro gas turbine Capstone C200 is available in various, fuel-specific versions with optimised fuel injection systems. The plant presented overall energetic efficiencies of 50.9%, 48.6% and 47.9% for natural gas, biogas and syngas operation, respectively. Due to very high natural gas and syngas prices, the cogeneration plant presented economic feasibility only in case of biogas operation, with short payback periods of approximately 2.8 years and high expected annual saving. Moreover, biogas has the highest ecologic efficiency and was therefore found to be the best alternative to fossil fuels / Mestre
|
204 |
Avaliação técnico-econômica da incorporação de ciclos combinados associados à gaseificadores de leito fluidizado circulante no setor sucroalcooleiro /Copa Rey, José Ramón. January 2018 (has links)
Orientador: Celso Eduardo Tuna / CoOrientador: José Luz Silveira / Banca: Eliana Vieira Canettieri / Banca: João Andrade de Carvalho Júnior / Banca: Christian Jeremi Coronado Rodriguez / Banca: Carlos Manuel Romero Luna / Resumo: O bagaço e a palha são resíduos do processamento industrial da cana-de-açúcar que constituem uma importante fonte de recurso para cogeração de energia no setor sucroalcooleiro. Os sistemas de cogeração neste setor geram potência mecânica ou elétrica e vapor, que são utilizados no próprio processo e o excedente é vendido as concessionárias de energia. Porém, estes sistemas encontram-se bem abaixo do potencial real. Uma alternativa tecnológica que poderá contribuir com a oferta de excedentes de energia elétrica é a introdução da tecnologia BIG-GT (gaseificadores de biomassa associados a turbina a gás e caldeira de recuperação). O presente trabalho, tem como objetivo o estudo termoeconômico da incorporação desta tecnologia em usinas sucroalcooleiras como alternativa para o aumento de geração de eletricidade. As análises energéticas e exergéticas foram realizadas para quatro possíveis configurações de uma usina sucroalcooleira com a integração da tecnologia BIG-GT com o objetivo de avaliar a eficiência de geração de eletricidade e vapor de processo, bem como o aproveitamento global de energia de cada uma delas. Na análise termoeconômica, é determinado o custo de produção de gás de gaseificação, eletricidade e vapor do processo no sistema proposto, assim como, tempo de recuperação do investimento. Na parte final do trabalho foi realizada a otimização multiobjetiva do sistema considerando três funções objetivo: tecnológica, econômica e ambiental, para identificar a configuração com... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: Bagasse and straw are residues from the industrial processing of sugarcane that constitute an important source for cogeneration of energy in the sugar-alcohol sector. The cogeneration systems in this sector generate mechanical or electrical power and steam, which are used in the process itself and the surplus is sold to energy distribution companies. However, these systems are well below real potential. One of the technological alternatives that may improve the supply of surplus electricity is the introduction of BIG-GT technology (biomass gasifier associated with gas turbine and Heat recovery steam generator). In this work, it is proposed to conduct thermoeconomic studies of the incorporation of this technology in the sugarcane ethanol plants as an alternative to increasing the supply of electricity generation. The energetic and exergetic analyses were performed for four possible configurations of a sugarcane ethanol plant with the integration of BIG-GT technology with the objective of evaluating the efficiency of electricity generation and process steam as well as the global energy utilization of each one of them. In the thermoeconomic analysis, it is determined the cost of production of producer gas, electricity and steam of the process in the proposed system, as well as the investment payback period. In the final part of the work, it is developed the multiobjective optimization of the system considering three objective functions: technological, thermoeconomic and environmental, for identifying the configuration with better behavior. According to the results obtained in the study, it is concluded that case III and case IV are presented as the best of the proposed options / Doutor
|
205 |
[en] DEVELOPMENT OF A METHODOLOGY FOR CALIBRATING A TURBINE METER USED FOR MEASURING THE DISPLACED AIR VOLUME AND DETERMINATION OF ITS UNCERTAINTY OF MEASUREMENT / [pt] DESENVOLVIMENTO DE UMA METODOLOGIA PARA A CALIBRAÇÃO DE UMA TURBINA UTILIZADA PARA MEDIÇÃO DO VOLUME DESLOCADO DE AR E DETERMINAÇÃO DA SUA INCERTEZA DE MEDIÇÃOFLAVIOMAR SOARES DE SOUZA 11 December 2007 (has links)
[pt] Tendo em vista que as normas existentes não apresentam uma
metodologia
em relação à calibração de medidores tipo turbina e a
determinação da incerteza
de medição do volume deslocado de gases neste medidor,
este trabalho apresenta
uma metodologia para sistematizar os processos de
calibração. Para isso, foi
utilizado uma bancada de calibração com uma turbina. Com
os dados obtidos nos
testes foi possível processar os resultados obtidos para a
determinação das
incertezas de medição das variáveis envolvidas e avaliar o
desempenho do
medidor. Os dados experimentais de temperatura, pressão e
rotação da turbina
foram obtidos para ar com uma bancada já existente em um
laboratório de
calibração, tanto para a turbina master como para o
objeto, e os resultados obtidos
neste estudo estão sendo utilizados para sua acreditação
junto à Rede Brasileira
de Calibração (RBC). Os procedimentos de teste foram
desenvolvidos a partir de
normas existentes, especificação dos equipamentos e seu
desempenho, em
condições que permitissem a otimização da incerteza de
medição, calculada de
acordo com o ISO GUM. Assim, foi mostrado que a incerteza
de medição de
volume com a turbina de teste decresce quando o volume de
gás utilizado
aumenta, até um valor aproximadamente constante, definindo
sua condição de
calibração. Finalmente, uma metodologia foi desenvolvida
para determinar o fator
da turbina (K-factor) como uma função contínua do volume
indicado pela turbina de
teste ao longo da sua faixa de utilização, simplificando o
procedimento a ser
utilizado. / [en] Due to the fact that the existing standards don´t have a
methodology related to
the calibration of turbine meters and determination of the
measurement uncertainty
of the displaced gas volume in this meter, this research
presents a methodology for
standardizing the calibration processes. It was made
possible by the use of a
turbine based calibration rig. By processing the data
acquired during the tests, it
was possible to determine the measurement uncertainty of
the involved variables
and to evaluate the meter performance. Its temperature and
pressure, together with
the turbine speed, were measured in an existing rig of a
calibration laboratory, for
both master and test turbines, and the results are being
used to accredit the
laboratory to the Brazilian Calibration Network (RBC). The
test procedures were
developed from existing standards for similar testes,
equipment specification and
performance, and test conditions that allow the
optimization of the uncertainty of
measurement, in accordance to ISO GUM. This way, it was
shown that the
uncertainty of measurement of volume with the test turbine
decreases when the gas
volume increases, up to an approximately constant value,
which determines the
calibration condition. Finally, a methodology was
developed to determine the turbine
calibration factor (K-Factor) as a continuous function of
the indicated value by the
teste turbine along its operation range, simplifying the
procedure to be used.
|
206 |
Alternatives to the use of the crowbar circuit in DFIG based wind turbines during balanced voltage dips. / Alternativas ao uso do sistema Crowbar em turbinas eólicas equipadas no DFIG durante afundamentos balanceados de tensão na rede.Avila Naranjo, Rafael Ricardo 17 July 2014 (has links)
Most of the modern wind turbines are based on doubly fed induction generators (DFIG), with a back to back power converter connecting the rotor to the network. It is known that voltage dips at the stator terminals can cause overcurrents in the rotor windings, which could threaten the converter integrity. In order to protect the converter, several strategies have been proposed in technical literature, requiring in some cases the converter deactivation, which disables the control that the converter has over the power transference between the generator and the system. This last is not a desirable behavior since it can put on risk the voltage stability of the electric system. It is the aim of this dissertation to introduce and compare five of those protection strategies, through the computational simulation of their performance in case of balanced voltage dips. In order to achieve this, the electromagnetic dynamic model of the DFIG was theoretically developed, as well as the models of the strategies of interest. Subsequently, the computational model of the system was assembled in the software Matlabs Simulink to finally perform the desired simulations and its corresponding analysis. / A maioria das turbinas eólicas modernas é baseada em geradores de indução duplamente alimentados (GIDE), com um back to back conversor de energia que liga o rotor para a rede. Sabe-se que as quedas de tensão nos terminais do estator podem causar sobrecorrentes nos enrolamentos do rotor, que podem ameaçar a integridade do conversor. A fim de proteger o conversor, várias estratégias têm sido propostas na literatura técnica, exigindo, em alguns casos, a desativação do conversor, o qual desativa o controlo do conversor, que possui ao longo da transferência de energia entre o gerador e o sistema. Este último não é um comportamento desejável, uma vez que pode colocar em risco a estabilidade de tensão do sistema elétrico. É o objetivo desta dissertação apresentar e comparar cinco dessas estratégias de proteção, através da simulação computacional de seu desempenho em caso de quedas de tensão equilibrada. A fim de alcançar este objetivo, o modelo dinâmico eletromagnética do DFIG teoricamente foi desenvolvido, bem como os modelos das estratégias de interesse. Subsequentemente, o modelo computacional do sistema foi montado no software Simulink do Matlab para finalmente executar as simulações desejadas e sua análise correspondente.
|
207 |
Efeito de remoção eletrolítica para reparo do revestimento de WC-10Co-4Cr aplicado por HVOF em aplicação de desgaste erosivo. / Effect of electrochemical removal for a WC-10Co-4Cr costing applied by HVOF in erosive wear application.Nagasima, Denis Marcel Pires 19 September 2018 (has links)
A operação de uma turbina hidráulica para hidrogeração alocada em um rio com sedimentos pode levar ao desgaste erosivo e, consequentemente, manutenção prematura do componente. Visando mitigar esse problema, em geral, aplicam-se revestimentos que aumentam a vida útil das turbinas, mas não eliminam o desgaste erosivo ocorrido, o que leva à necessidade de reparo do componente. O reparo se inicia com a remoção do revestimento remanescente e reconstituição da geometria por solda, para então, reaplicação de um novo revestimento. Nem sempre as regiões afetadas são grandes, o que possibilitaria a aplicação de um reparo por soldagem e também reparo de revestimento localizado na turbina. O reparo sobre o revestimento pode ser aplicado tanto na recuperação de componentes que sofrem desgaste erosivo, bem como, para consertar problemas ocorridos durante o processo de revestimento anterior. O presente trabalho visa compreender e verificar a possibilidade de reparo em um revestimento de WC-10Co-4Cr executado pelo processo de aspersão térmica HVOF (high velocity oxy fuel), bem como, suas limitações em desgaste erosivo. O estudo foca na preparação sobre um revestimento existente (remoção eletroquímica) e aplicação de uma nova camada. Como avaliação inicial o trabalho considerou o ensaio de desgaste erosivo, onde foi encontrado aumento de 22% na quantidade de material erodido nos corpos de prova com reparo. A observação e comparação dos corpos de prova com e sem reparo, utilizando microscopia eletrônica de varredura (MEV), mostra que a diferença em desgaste está na delaminação entre camadas devido à falha coesiva, a qual pôde ser observada através do ensaio de adesão. A falha coesiva pode ser explicada com base em análise por EDS dos corpos de prova, por intermédio da qual foi verificado um aumento na quantidade de oxigênio e, consequentemente, presença de óxido na preparação superficial por remoção eletroquímica. / The operation of a hydraulic turbine for hydropower generation located in a river with sediments can lead to erosive wear, and, as a consequence, premature maintenance of the component. In order to minimize such problem, coatings are applied to increase turbine lifetime, but they do not eliminate erosive wear, which leads to the necessity of component repair. The repair starts with the removal of the remaining coating and reconstitution of the geometry by welding, and then reapplication of a new coating. The affected regions are not necessarily large, which would allow the application of a localized repair by welding and localized repair by coating. The coating repair can be applied in two situations: recovery of components with erosive wear and to fix problems during coating manufacturing. The present work aims to understand and verify the possibility of repair in a WC-10Co-4Cr coating performed by the thermal spraying HVOF process (high velocity oxy fuel), as well as, its limitations in erosive wear. This study focuses in the preparation of an existing coating (electrochemical removal) and application of new coating layers. The start point was an evaluation using an erosion test rig, which indicated an increase of 22% in material removal for the test samples with repair. Using scanning electron microscope (SEM), the test samples with and without repair were compared and showed a wear difference related to delamination between layers due to cohesive failure, which was also observed in the adhesion test. The cohesive failure can be explained by EDS, where it was found a high content of oxygen in the repaired zones, and, as a consequence, presence of oxide in the surface preparation by electrochemical removal.
|
208 |
Resfriamento de ar de entrada em turbinas a gás no parque gerador elétrico brasileiro / Cooling air inlet gas turbine electric generating facilities in BrazilCarvalho Junior, Manoel Lélio Martins de 27 April 2012 (has links)
Nos últimos 15 anos houve um grande aumento na presença de turbinas a gás no parque gerador de eletricidade brasileiro. O Brasil tem predominantemente climas tropicais e subtropicais com temperaturas oscilando entre 20 e 35C na maior parte do ano. A máxima potência que pode ser gerada por uma turbina a gás aumenta com a redução da temperatura do ar de entrada na turbina. Decorre daí o interesse na aplicação de sistemas de resfriamento do ar de entrada de turbinas. Dentre os sistemas de resfriamento, os de aplicação mais simples são o de resfriamento por meio evaporativo rígido e o de resfriamento por ciclo de compressão com acionamento elétrico. Não há na literatura um estudo sistemático da aplicação de sistemas de resfriamento de ar de entrada de turbinas a gás para operação no Brasil. Este trabalho estuda a aplicação dos dois tipos mais simples de sistemas de resfriamento de ar de entrada em turbinas operando ou a serem instaladas no território brasileiro. Um modelo para simulação da resposta de turbinas a gás às variações nas condições climáticas do ar de entrada (temperatura, umidade e pressão atmosférica) é desenvolvido. O modelo necessita como parâmetros somente de dados publicados em catálogo pelo fabricante da turbina. A simulação é feita para 27 localidades brasileiras comparando a operação de um mesmo tipo de turbina sem resfriamento e com os dois tipos de resfriamento. O dados climáticos usados são dos tipos anos metereológicos típicos e anos teste de referência. O modelo de turbina desenvolvido simula de maneira satisfatória as curvas de uma turbina comercial do tipo heavy duty. Um aumento de energia anual gerada de até 4,2% foi observado para o sistema de resfriamento por meio evaporativo rígido. O aumento de energia no resfriamento evaporativo depende da depressão de bulbo úmido média do local de instalação da turbina. Para o resfriamento por ciclo de compressão com acionamento elétrico o aumento observado foi de até 11,2%. O aumento de energia para este tipo de sistema depende da temperatura de bulbo seco média do local. / In the last 15 years an ever increasing presence of gas turbines was felt in electrical power generation in Brazil. Tropical and subtropical climates dominate most of the country, with temperatures ranging from 20 to 35C during most of the year. The maximum power that can be generated by a gas turbine increases at lower inlet air temperatures. Consequently, there is great interest in applying inlet air cooling systems in gas turbines. Among the inlet air cooling systems, the evaporative cooling by rigid wet media and the compression thermal cycle with electrical power chiller systems are the ones with most straightforward implementation. There is no systematic study of the application of gas turbine inlet air cooling systems for turbines operating in Brazil. This thesis studies the application of the two methods of gas turbine inlet air cooling mentioned above in turbines operating or to be installed in Brazil. A model to simulate the response of gas turbines to changes in the inlet air (temperature, humidity and pressure) is developed. The model uses turbine catalogue data as parameters. The simulation is performed for 27 Brazilian locations, comparing the operation of a model of turbine operating with and without cooling systems, for both types of cooling systems. Typical meteorological year and test reference year data are used in the study. The turbine model developed reproduces the turbines data curves with satisfactory accuracy. An annual increase in energy generation of up to 4,2% was observed for evaporative cooling. The energy gain for evaporative cooling depends on the annual mean wet bulb depression of the local. The compression thermal cycle increases the annual energy generation by up to 11,2%. The energy increase in this type of system depends on the mean dry bulb temperature of the local.
|
209 |
Design de difusor aerodinâmico compacto para uma turbina eólica de pequena escalaXimenes, Fernando Silveira January 2018 (has links)
Este trabalho tem como proposta desenvolver um difusor aerodinâmico compacto para uma turbina eólica de pequena escala, objetivando alcançar um melhor start rotacional (menor torque de partida para rotacionar) em baixas velocidades de vento. Um difusor é uma estrutura em forma de aro envolta ao rotor da turbina eólica, sua função é amplificar a captação e aceleração do vento, explorando os efeitos aerodinâmicos das zonas de vórtices de baixa pressão na saída do difusor. O estudo concentrar-se-á na manipulação da geometria dos difusores, analisando como seu design impacta no seu comportamento aerodinâmico impacta na capacidade do difusor equacionar as zonas de alta e baixa pressão ao longo de sua estrutura, essa relação é determinante para o efeito aerodinâmico que acelera o escoamento de ar, resultando em um start rotacional em baixas velocidade de vento. O ponto de partida para este trabalho são os estudos desenvolvidos por Ohya et al. (2010) sobre difusores compactos-flangeados (compact-type brimmed diffuser) para turbinas eólicas, denominado Wind-lens Technology. Para alcançar os objetivos, esta pesquisa vai utilizar simulações por CFD com software de túnel de vento virtual e ensaios experimentais em túnel de vento físico para avaliar o comportamento dinâmico (turbina + difusor). Foram desenvolvidas dezenove geometrias a partir de uma área construtiva padronizada para o design de difusores. Desenvolveu-se também, a partir dos resultados encontrados, um MFI (microseparador de fluxo interno), que consiste em uma estrutura adicional com função de potencializar as zonas de vórtices (baixa pressão) no plano de saída do escoamento de ar dos difusores. Os resultados mostraram que a manipulação da geometria do difusor produziu resultados promissores em comparação com o modelo de referência, alcançando em algumas geometrias de difusores um melhor start rotacional. O MFI mostrou-se eficaz para potencializar as zonas de baixa pressão e melhorou o start rotacional. Ao final, definiu-se dois modelos de difusores e suas respectivas versões com MFI como as melhores opções para o start rotacional. / This work aims to develop a compact wind turbine for a turbine and a small scale, aiming at a better rotational start at low wind speeds (lower starting torque to rotate). A diffuser is a rim-shaped structure wrapped around the wind turbine rotor, its function is to amplify the wind uptake and acceleration, exploiting the aerodynamic effects of the low-pressure vortex zones at the diffuser outlet. The study will focus on the manipulation of the diffuser geometry, analyzing how its design impacts on its aerodynamic behavior, especially on the diffuser's ability to equate the high and low pressure zones along its structure, this relation is decisive for the aerodynamic effect that accelerates the air flow, resulting in a rotational start at low wind speeds. The basis for this work are studies developed by Ohya et al. (2010) on compact-flanged diffusers for wind turbines, called Wind-lens Technology. To achieve the objectives, this research will use CFD simulations with virtual wind tunnel software and experimental tests in physical wind tunnel to evaluate the dynamic behavior (turbine + diffuser). Nineteen geometries were developed from a standardized design area for the design of diffusers. An MFI (internal flow microseparator) has also been developed, which is an additional structure whose function is to potentiate the low pressure zones of the diffusers. The results showed that the manipulation of the diffuser geometry produced promising results in comparison to the reference model, reaching in some conditions superior results in RPM and initial start. The MFI proved to be effective in boosting the low pressure zones and improved the initial start. At the end, two models of diffusers and their respective versions with MFI were defined as the best options for the initial start.
|
210 |
Dimensionamiento de las tuberías forzadas y selección de turbinas para la minicentral hidroelétrica del distrito de Monobamba. Provincia de Jauja. Departamento de JunínPari Llantoy, Angel January 2018 (has links)
Publicación a texto completo no autorizada por el autor / El documento digital no refiere asesor / Aborda el dimensionamiento de las tuberías forzadas y la selección de las turbinas para la minicentral hidroeléctrica de Monobamba, en la provincia de Jauja, departamento de Junín, como parte del proyecto integral de repotenciación y mejoramiento de la central. Ante la insuficiente generación de energía eléctrica y el deficiente servicio ofrecido a la comunidad, debido al deterioro de las estructuras hidráulicas de captación y conducción y de las turbinas hidráulicas, el proyecto consideró un incremento del caudal de captación a 1,558 m3 /s. Este caudal será conducido a la central mediante tres líneas de tuberías forzadas de acero estructural tipo A-36 con diámetros de 0.48 m, ¼ de pulgada de espesor y 83 m de longitud cada una. Con los datos de altura neta de 41,07 m y el caudal de 0,556 m3 /se seleccionaron tres turbinas hidráulicas, dos de ellas tipo Michell Banki (crossflow) y otro tipo Francis, ambas de eje horizontal, con potencia en el eje de 180 kW cada una y con eficiencia estimada del 80%. / Trabajo de suficiencia profesional
|