• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 36
  • 1
  • Tagged with
  • 37
  • 32
  • 21
  • 20
  • 18
  • 16
  • 13
  • 13
  • 12
  • 12
  • 12
  • 10
  • 10
  • 9
  • 8
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Modelos analíticos no estudo do comportamento estrutural de tubos flexíveis e cabos umbilicais. / Analytical models for the study of the structural behavior of flexible pipes and umbilical cables.

Roberto Ramos Junior 21 December 2001 (has links)
Tubos flexíveis e cabos umbilicais têm sido bastante utilizados pela indústria petrolífera em aplicações offshore nos últimos anos. Os primeiros consistem num tipo de tubulação usada para o transporte de vários tipos de fluidos, geralmente trabalhando a alta pressão. Já os cabos umbilicais são usados para permitir o controle e a comunicação entre equipamentos submersos e de superfície. Quanto à concepção estrutural, os dois tipos de produto são muito semelhantes, apresentando diversas camadas metálicas combinadas com camadas plásticas concêntricas de modo a formar uma estrutura com grande rigidez axial e torcional, porém baixa rigidez flexional. O escopo deste trabalho é o estudo de modelos analíticos para a previsão do comportamento estrutural de tubos flexíveis e cabos umbilicais. Inicialmente são propostos modelos para a análise local destas estruturas, sob a ação de carregamentos de tração, torção, pressão interna, externa e flexão, agindo isoladamente ou combinados. São propostos modelos analíticos consistentes para cada camada, resultando num sistema de equações algébricas que, ao ser resolvido, fornece os valores de tensões e deformações nas diversas camadas, bem como os valores de rigidez equivalente axial, flexional e torcional do tubo/cabo. São feitas várias comparações entre os resultados obtidos analiticamente e resultados experimentais obtidos na literatura para diversos tubos e cabos. A importância dos modelos desenvolvidos fica evidente numa análise do comportamento global para a previsão de instabilidade de linhas sob carregamento combinado de torção e compressão dinâmica. Através de uma análise consistente, mostra-se que a clássica equação de Greenhill também pode ser utilizada para a determinação das cargas críticas de flambagem em barras curvas de grande comprimento, sendo o comprimento de flambagem da barra estimado a partir da relação de dispersão de onda flexional numa viga reta. Vários exemplos de determinação da carga crítica de flambagem são abordados, envolvendo tanto risers rígidos quanto flexíveis. Uma atenção especial ao estabelecimento e discussão de hipóteses é dada em todos os modelos propostos. / Flexible pipes and umbilical cables have been largely used by the oil industry in offshore applications in these last years. The former are a kind of pipeline structure used for conducting several fluids, often working at high pressure, while the latter are cables used to provide control and communication links between seafloor and surface equipments. Regarding their structural design, both flexible pipes and umbilicals are quite similar, presenting a number of steel armour layers combined with polymeric layers disposed in such a way to form a structure which is stiff under torsion and traction, but compliant under bending. The aim of this work is the study of analytical models to predict the structural behaviour of flexible pipes and umbilicals. At first, local analysis of such structures is undertaken, considering combined loadings of traction, torsion, internal and external pressures and bending. Consistent analytical models, proposed for each layer, are then combined to result in a system of algebraic equations that is solved for the stresses and deformations in the layers. Equivalent axial, torsional and flexural stiffness values for the pipe/umbilical are also obtained. Several comparisons between analytical results and experimental results obtained in the literature are also made, involving both flexible pipes and umbilicals. The importance of the developed models is highlighted in an analysis of the global structural behaviour made to predict the instability condition of flexible lines under the action of dynamic compression and twisting moment. Through a consistent analysis, it is shown that the classical Greenhill formula can also be used to determine critical buckling loads for long curved rods. In this case, an estimate for the buckling lenght is given by the flexural wave dispersion relation of a straight beam. Several examples, involving both SCRs and flexible pipes, illustrate the method of critical buckling load determination. Emphasis is also given in the establishment and discussion of hypotheses for all proposed models.
2

O estudo doppler da função cardíaca fetal e da artéria umbilical na rotura prematura das membranas amnióticas pré-termo

Müller, Ana Lúcia Letti January 2009 (has links)
Introdução: A conduta padrão para gestante com Rotura Prematura das Membranas Amnióticas (ROPREMA) com idade gestacional (IG) inferior a 34 semanas, sem trabalho de parto e sem evidências clínicas de infecção ou sofrimento fetal é a expectante, onde a interrupção só é feita quando se identificam sinais de infecção ou comprometimento fetal, pois as complicações da prematuridade pesam mais. No feto, a infecção intrauterina é também conhecida como Síndrome de Resposta Inflamatória Fetal (SRIF). Já se sabe que em mais de 50% dos casos de ROPREMA pré-termo os fetos desenvolverão a SRIF, e identificá-la torna-se importante no manejo das complicações neonatais. Alguns estudos têm demonstrado que a interrupção da gestação antes das 34 semanas pode ser benéfica para fetos já atingidos pela infecção, não diagnosticada pelos métodos atualmente usados. Objetivos: Verificar se existe associação entre as alterações do Doppler cardíaco e da artéria umbilical e a SRIF, confirmada por sepse neonatal e corioamnionite histológica em pacientes com ROPREMA pré-termo, para interferência no manejo expectante. Métodos: Realizado estudo de coorte controlado com pacientes com gestação única, maiores de 18 anos, com ROPREMA confirmada, atendidas no Centro Obstétrico do Hospital de Clínicas de Porto Alegre (CO – HCPA), com IG entre 24 a 33 semanas e 4 dias, que internaram para conduta expectante, no período de outubro de 2007 a março de 2008. A conduta incluiu uso de corticóide, rastreamento de infecções através do hemograma e realização de perfil biofísico fetal (PBF) diário nestas pacientes de acordo com a rotina. Além disso, realizou-se ecocardiografia fetal com Doppler e estudo Doppler da artéria umbilical a cada 7-10 dias até a interrupção da gestação. Os controles foram pacientes com gestação única de evolução normal, com a mesma IG e com pré-natal em unidade básica de saúde, incluídas com a realização da ecocardiografia fetal, acompanhadas até o nascimento. As placentas com seus anexos foram enviados para exame histopatológico e foram acompanhados os recém-nascidos (RNs) para investigação do diagnóstico de sepse neonatal. Resultados: Foram incluídas 15 pacientes com ROPREMA pré-termo (grupo 1) e 15 controles (grupo 2). A sepse neonatal foi diagnosticada em 73,3% e a corioamnionite histológica confirmou-se como marcador para a SRIF em 86,7% das pacientes do grupo 1 versus 6,7% de sepse e 26,7% de corioamnionite no grupo 2 (P < 0,001 e 0,003, respectivamente), onde também houve casos de ROPREMA a termo, com indução imediata do parto. No grupo 1, o PBF só foi alterado em 30% das pacientes, o hemograma mostrou-se infeccioso em 35%, a infecção ovular clínica só foi diagnosticada em 20%, e 27,3% dos RNs sépticos tiveram sua gestação interrompida somente pela IG limite de 34 semanas. Os parâmetros do Doppler cardíaco como o tempo de ejeção e o índice Tei (índice de desempenho miocárdico) do ventrículo esquerdo mostraram diferença significativa entre os grupos (P=0,003 e 0,007 respectivamente). O índice Tei foi mais alto no grupo 1 do que no grupo 2 (0,628 x 0,508), onde o valor dos controles normais foi semelhante aos valores encontrados na literatura. A média do índice de resistência (IR) da artéria umbilical das pacientes do grupo 1 foi estatisticamente diferente da média utilizada nos exames de ultrassonografia na população, considerando-se a amostra de controles representativa da mesma (0,661 x 0,611; P=0,02). No grupo 1, o IR também mostrou diferença significativa entre os RNs sépticos e os não-sépticos (0,692 x 0,576; P=0,003). Os valores do IR da artéria umbilical das pacientes com ROPREMA cujos RNs foram diagnosticados com sepse neonatal estavam no limite superior da normalidade deste índice de acordo com os achados da literatura. Conclusões: O estudo demonstrou que existem alterações do Doppler cardíaco e da artéria umbilical em pacientes com ROPREMA pré-termo, possivelmente relacionadas com a presença de comprometimento inflamatório fetal confirmado pelo diagnóstico de corioamnionite e sepse neonatal. Este achado pode interferir na atual conduta utilizada no manejo expectante da ROPREMA pré-termo, levando à interrupção da gestação antes de 34 semanas.
3

O estudo doppler da função cardíaca fetal e da artéria umbilical na rotura prematura das membranas amnióticas pré-termo

Müller, Ana Lúcia Letti January 2009 (has links)
Introdução: A conduta padrão para gestante com Rotura Prematura das Membranas Amnióticas (ROPREMA) com idade gestacional (IG) inferior a 34 semanas, sem trabalho de parto e sem evidências clínicas de infecção ou sofrimento fetal é a expectante, onde a interrupção só é feita quando se identificam sinais de infecção ou comprometimento fetal, pois as complicações da prematuridade pesam mais. No feto, a infecção intrauterina é também conhecida como Síndrome de Resposta Inflamatória Fetal (SRIF). Já se sabe que em mais de 50% dos casos de ROPREMA pré-termo os fetos desenvolverão a SRIF, e identificá-la torna-se importante no manejo das complicações neonatais. Alguns estudos têm demonstrado que a interrupção da gestação antes das 34 semanas pode ser benéfica para fetos já atingidos pela infecção, não diagnosticada pelos métodos atualmente usados. Objetivos: Verificar se existe associação entre as alterações do Doppler cardíaco e da artéria umbilical e a SRIF, confirmada por sepse neonatal e corioamnionite histológica em pacientes com ROPREMA pré-termo, para interferência no manejo expectante. Métodos: Realizado estudo de coorte controlado com pacientes com gestação única, maiores de 18 anos, com ROPREMA confirmada, atendidas no Centro Obstétrico do Hospital de Clínicas de Porto Alegre (CO – HCPA), com IG entre 24 a 33 semanas e 4 dias, que internaram para conduta expectante, no período de outubro de 2007 a março de 2008. A conduta incluiu uso de corticóide, rastreamento de infecções através do hemograma e realização de perfil biofísico fetal (PBF) diário nestas pacientes de acordo com a rotina. Além disso, realizou-se ecocardiografia fetal com Doppler e estudo Doppler da artéria umbilical a cada 7-10 dias até a interrupção da gestação. Os controles foram pacientes com gestação única de evolução normal, com a mesma IG e com pré-natal em unidade básica de saúde, incluídas com a realização da ecocardiografia fetal, acompanhadas até o nascimento. As placentas com seus anexos foram enviados para exame histopatológico e foram acompanhados os recém-nascidos (RNs) para investigação do diagnóstico de sepse neonatal. Resultados: Foram incluídas 15 pacientes com ROPREMA pré-termo (grupo 1) e 15 controles (grupo 2). A sepse neonatal foi diagnosticada em 73,3% e a corioamnionite histológica confirmou-se como marcador para a SRIF em 86,7% das pacientes do grupo 1 versus 6,7% de sepse e 26,7% de corioamnionite no grupo 2 (P < 0,001 e 0,003, respectivamente), onde também houve casos de ROPREMA a termo, com indução imediata do parto. No grupo 1, o PBF só foi alterado em 30% das pacientes, o hemograma mostrou-se infeccioso em 35%, a infecção ovular clínica só foi diagnosticada em 20%, e 27,3% dos RNs sépticos tiveram sua gestação interrompida somente pela IG limite de 34 semanas. Os parâmetros do Doppler cardíaco como o tempo de ejeção e o índice Tei (índice de desempenho miocárdico) do ventrículo esquerdo mostraram diferença significativa entre os grupos (P=0,003 e 0,007 respectivamente). O índice Tei foi mais alto no grupo 1 do que no grupo 2 (0,628 x 0,508), onde o valor dos controles normais foi semelhante aos valores encontrados na literatura. A média do índice de resistência (IR) da artéria umbilical das pacientes do grupo 1 foi estatisticamente diferente da média utilizada nos exames de ultrassonografia na população, considerando-se a amostra de controles representativa da mesma (0,661 x 0,611; P=0,02). No grupo 1, o IR também mostrou diferença significativa entre os RNs sépticos e os não-sépticos (0,692 x 0,576; P=0,003). Os valores do IR da artéria umbilical das pacientes com ROPREMA cujos RNs foram diagnosticados com sepse neonatal estavam no limite superior da normalidade deste índice de acordo com os achados da literatura. Conclusões: O estudo demonstrou que existem alterações do Doppler cardíaco e da artéria umbilical em pacientes com ROPREMA pré-termo, possivelmente relacionadas com a presença de comprometimento inflamatório fetal confirmado pelo diagnóstico de corioamnionite e sepse neonatal. Este achado pode interferir na atual conduta utilizada no manejo expectante da ROPREMA pré-termo, levando à interrupção da gestação antes de 34 semanas.
4

O estudo doppler da função cardíaca fetal e da artéria umbilical na rotura prematura das membranas amnióticas pré-termo

Müller, Ana Lúcia Letti January 2009 (has links)
Introdução: A conduta padrão para gestante com Rotura Prematura das Membranas Amnióticas (ROPREMA) com idade gestacional (IG) inferior a 34 semanas, sem trabalho de parto e sem evidências clínicas de infecção ou sofrimento fetal é a expectante, onde a interrupção só é feita quando se identificam sinais de infecção ou comprometimento fetal, pois as complicações da prematuridade pesam mais. No feto, a infecção intrauterina é também conhecida como Síndrome de Resposta Inflamatória Fetal (SRIF). Já se sabe que em mais de 50% dos casos de ROPREMA pré-termo os fetos desenvolverão a SRIF, e identificá-la torna-se importante no manejo das complicações neonatais. Alguns estudos têm demonstrado que a interrupção da gestação antes das 34 semanas pode ser benéfica para fetos já atingidos pela infecção, não diagnosticada pelos métodos atualmente usados. Objetivos: Verificar se existe associação entre as alterações do Doppler cardíaco e da artéria umbilical e a SRIF, confirmada por sepse neonatal e corioamnionite histológica em pacientes com ROPREMA pré-termo, para interferência no manejo expectante. Métodos: Realizado estudo de coorte controlado com pacientes com gestação única, maiores de 18 anos, com ROPREMA confirmada, atendidas no Centro Obstétrico do Hospital de Clínicas de Porto Alegre (CO – HCPA), com IG entre 24 a 33 semanas e 4 dias, que internaram para conduta expectante, no período de outubro de 2007 a março de 2008. A conduta incluiu uso de corticóide, rastreamento de infecções através do hemograma e realização de perfil biofísico fetal (PBF) diário nestas pacientes de acordo com a rotina. Além disso, realizou-se ecocardiografia fetal com Doppler e estudo Doppler da artéria umbilical a cada 7-10 dias até a interrupção da gestação. Os controles foram pacientes com gestação única de evolução normal, com a mesma IG e com pré-natal em unidade básica de saúde, incluídas com a realização da ecocardiografia fetal, acompanhadas até o nascimento. As placentas com seus anexos foram enviados para exame histopatológico e foram acompanhados os recém-nascidos (RNs) para investigação do diagnóstico de sepse neonatal. Resultados: Foram incluídas 15 pacientes com ROPREMA pré-termo (grupo 1) e 15 controles (grupo 2). A sepse neonatal foi diagnosticada em 73,3% e a corioamnionite histológica confirmou-se como marcador para a SRIF em 86,7% das pacientes do grupo 1 versus 6,7% de sepse e 26,7% de corioamnionite no grupo 2 (P < 0,001 e 0,003, respectivamente), onde também houve casos de ROPREMA a termo, com indução imediata do parto. No grupo 1, o PBF só foi alterado em 30% das pacientes, o hemograma mostrou-se infeccioso em 35%, a infecção ovular clínica só foi diagnosticada em 20%, e 27,3% dos RNs sépticos tiveram sua gestação interrompida somente pela IG limite de 34 semanas. Os parâmetros do Doppler cardíaco como o tempo de ejeção e o índice Tei (índice de desempenho miocárdico) do ventrículo esquerdo mostraram diferença significativa entre os grupos (P=0,003 e 0,007 respectivamente). O índice Tei foi mais alto no grupo 1 do que no grupo 2 (0,628 x 0,508), onde o valor dos controles normais foi semelhante aos valores encontrados na literatura. A média do índice de resistência (IR) da artéria umbilical das pacientes do grupo 1 foi estatisticamente diferente da média utilizada nos exames de ultrassonografia na população, considerando-se a amostra de controles representativa da mesma (0,661 x 0,611; P=0,02). No grupo 1, o IR também mostrou diferença significativa entre os RNs sépticos e os não-sépticos (0,692 x 0,576; P=0,003). Os valores do IR da artéria umbilical das pacientes com ROPREMA cujos RNs foram diagnosticados com sepse neonatal estavam no limite superior da normalidade deste índice de acordo com os achados da literatura. Conclusões: O estudo demonstrou que existem alterações do Doppler cardíaco e da artéria umbilical em pacientes com ROPREMA pré-termo, possivelmente relacionadas com a presença de comprometimento inflamatório fetal confirmado pelo diagnóstico de corioamnionite e sepse neonatal. Este achado pode interferir na atual conduta utilizada no manejo expectante da ROPREMA pré-termo, levando à interrupção da gestação antes de 34 semanas.
5

Modelos analíticos no estudo do comportamento estrutural de tubos flexíveis e cabos umbilicais. / Analytical models for the study of the structural behavior of flexible pipes and umbilical cables.

Ramos Junior, Roberto 21 December 2001 (has links)
Tubos flexíveis e cabos umbilicais têm sido bastante utilizados pela indústria petrolífera em aplicações offshore nos últimos anos. Os primeiros consistem num tipo de tubulação usada para o transporte de vários tipos de fluidos, geralmente trabalhando a alta pressão. Já os cabos umbilicais são usados para permitir o controle e a comunicação entre equipamentos submersos e de superfície. Quanto à concepção estrutural, os dois tipos de produto são muito semelhantes, apresentando diversas camadas metálicas combinadas com camadas plásticas concêntricas de modo a formar uma estrutura com grande rigidez axial e torcional, porém baixa rigidez flexional. O escopo deste trabalho é o estudo de modelos analíticos para a previsão do comportamento estrutural de tubos flexíveis e cabos umbilicais. Inicialmente são propostos modelos para a análise local destas estruturas, sob a ação de carregamentos de tração, torção, pressão interna, externa e flexão, agindo isoladamente ou combinados. São propostos modelos analíticos consistentes para cada camada, resultando num sistema de equações algébricas que, ao ser resolvido, fornece os valores de tensões e deformações nas diversas camadas, bem como os valores de rigidez equivalente axial, flexional e torcional do tubo/cabo. São feitas várias comparações entre os resultados obtidos analiticamente e resultados experimentais obtidos na literatura para diversos tubos e cabos. A importância dos modelos desenvolvidos fica evidente numa análise do comportamento global para a previsão de instabilidade de linhas sob carregamento combinado de torção e compressão dinâmica. Através de uma análise consistente, mostra-se que a clássica equação de Greenhill também pode ser utilizada para a determinação das cargas críticas de flambagem em barras curvas de grande comprimento, sendo o comprimento de flambagem da barra estimado a partir da relação de dispersão de onda flexional numa viga reta. Vários exemplos de determinação da carga crítica de flambagem são abordados, envolvendo tanto risers rígidos quanto flexíveis. Uma atenção especial ao estabelecimento e discussão de hipóteses é dada em todos os modelos propostos. / Flexible pipes and umbilical cables have been largely used by the oil industry in offshore applications in these last years. The former are a kind of pipeline structure used for conducting several fluids, often working at high pressure, while the latter are cables used to provide control and communication links between seafloor and surface equipments. Regarding their structural design, both flexible pipes and umbilicals are quite similar, presenting a number of steel armour layers combined with polymeric layers disposed in such a way to form a structure which is stiff under torsion and traction, but compliant under bending. The aim of this work is the study of analytical models to predict the structural behaviour of flexible pipes and umbilicals. At first, local analysis of such structures is undertaken, considering combined loadings of traction, torsion, internal and external pressures and bending. Consistent analytical models, proposed for each layer, are then combined to result in a system of algebraic equations that is solved for the stresses and deformations in the layers. Equivalent axial, torsional and flexural stiffness values for the pipe/umbilical are also obtained. Several comparisons between analytical results and experimental results obtained in the literature are also made, involving both flexible pipes and umbilicals. The importance of the developed models is highlighted in an analysis of the global structural behaviour made to predict the instability condition of flexible lines under the action of dynamic compression and twisting moment. Through a consistent analysis, it is shown that the classical Greenhill formula can also be used to determine critical buckling loads for long curved rods. In this case, an estimate for the buckling lenght is given by the flexural wave dispersion relation of a straight beam. Several examples, involving both SCRs and flexible pipes, illustrate the method of critical buckling load determination. Emphasis is also given in the establishment and discussion of hypotheses for all proposed models.
6

Valores de referência para área de secção transversa do cordão e vasos umbilicais aferidos pela ultrassonografia em gestações gemelares dicoriônicas / Reference values for cross-sectional area of the umbilical cord and vessels measured by ultrasound in dichorionic twin pregnancies

Fernandes, Douglas Bandeira 14 May 2014 (has links)
OBJETIVO: Determinar os valores de referência, e examinar a correlação da área de secção transversa do cordão umbilical, e de seus componentes, com a idade gestacional (IG), em gestações gemelares. Examinar a correlação da área de secção transversa do cordão umbilical com o peso fetal estimado (PFE). MATERIAIS E MÉTODOS: Estudo prospectivo longitudinal envolvendo gestações gemelares dicoriônicas, não complicadas. Medidas ultrassonográficas das áreas de secção transversa do cordão umbilical (ASTCU), da veia (AVU) e artérias umbilicais (AAU), e da geleia de Wharton (AGW) foram obtidas em plano adjacente, próximo ao abdômen fetal, a cada três semanas. A correlação entre os parâmetros avaliados e a idade gestacional foi investigada por meio de modelo de regressão polinomial hierárquica, levando-se em consideração a variância segundo a idade gestacional, entre medidas obtidas em fetos da mesma gestação e, entre diferentes gestações. Para cada parâmetro estudado, foram calculados os valores correspondentes aos percentis 5, 10, 50, 90 e 95, para cada semana gestacional. RESULTADOS: Foram realizadas 334 avaliações ultrassonográficas em 44 gestações gemelares, entre 18 e 33 semanas (média: 3,8 ± 0,7 exames/gestação; intervalo médio entre exames: 3,3 ± 0,9 semanas). Os valores log-transformados de todos os parâmetros avaliados apresentaram correlação significativa (p<0,001) com a idade gestacional: Log(ASTCU) = - 2,287498 + 0,149298 x IG - 0,002302 x IG2, desvio-padrão DP = 0,113, R2 = 0,65; Log (AVU) = - 2,721487 + 0,119853 x IG - 0,001507 x IG2, DP=0,165, R2 = 0,58; Log (AAU) = - 4,223546 + 0,195454 x IG - 0,003080 x IG2, DP=0,163, R2 = 0,57; Log (AGW) = - 2,511648 + 0,157737 x IG - 0,002564 x IG2, DP=0,123, R2 = 0,55. A área de secção transversa do cordão umbilical apresentou correlação significativa com o peso fetal estimado (Log (ASTCU) = -1,602447 + 0,554502 x Log (PFE), R2 = 0,65, p < 0,001). CONCLUSÃO: Em gestações gemelares dicoriônicas, a área de secção transversa do cordão umbilical, e de seus componentes, mostram correlação positiva e significativa com a idade gestacional. A área de secção transversa do cordão umbilical também correlaciona-se significativamente com o peso fetal estimado / OBJECTIVE: To determine reference values, and examine the correlation between the cross-sectional area of the umbilical cord, and its components, with gestational age (GA) in twin pregnancies. To examine the correlation between the cross-sectional area of the umbilical cord with the estimated fetal weight (EFW). MATERIALS AND METHODS: A prospective longitudinal study involving uncomplicated dichorionic twin pregnancies. Sonographic measurements of the cross-sectional areas of the umbilical cord (UCCSA), umbilical vein (UVA) and arteries (UAA) and Wharton\'s jelly (WGA) were obtained in a plane adjacent to the fetal abdomen, every three weeks. The correlation between these parameters and gestational age was examined with hierarchical polynomial regression analysis. This modeling took into account the variance according to gestational age, fetuses within the same pregnancy and changes across different pregnancies. For each parameter, 5th, 10th, 50th, 90th and 95th centiles were calculated for each gestational week. RESULTS: 334 ultrasound scans were performed in 44 twin pregnancies, between 18 and 33 weeks (mean: 3.8 ± 0.7 scans/pregnancy, mean interval between scans: 3.3 ± 0.9 weeks). All umbilical cord log-transformed values showed a significant correlation (p < 0.001) with gestational age: Log (UCCSA) = - 2.287498 + 0.149298 x GA - 0.002302 x IG2, SD = standard deviation 0.113, R2 = 0.65, Log (UVA) = - 2.721487 + 0.119853 x GA - 0.001507 x IG2, SD = 0.165, R2 = 0.58, Log (UAA) = - 4.223546 + IG x 0.195454 - 0.003080 x IG2, SD = 0.163, R2 = 0.57, Log (WGA) = - 2.511648 + 0.157737 x GA - 0.002564 x IG2 , SD = 0.123, R2 = 0.55. The cross-sectional area of the umbilical cord also correlated significantly with the estimated fetal weight (Log (UCCSA) = -1.602447 + 0.554502 x Log (EFW), R2 = 0.65, p < 0.001). CONCLUSION: In dichorionic twin pregnancies, the cross-sectional areas of the umbilical cord, and its components, show a positive and significant correlation with gestational age. The cross-sectional area of the umbilical cord also has correlates significantly with the estimated fetal weight
7

Valores de referência para área de secção transversa do cordão e vasos umbilicais aferidos pela ultrassonografia em gestações gemelares dicoriônicas / Reference values for cross-sectional area of the umbilical cord and vessels measured by ultrasound in dichorionic twin pregnancies

Douglas Bandeira Fernandes 14 May 2014 (has links)
OBJETIVO: Determinar os valores de referência, e examinar a correlação da área de secção transversa do cordão umbilical, e de seus componentes, com a idade gestacional (IG), em gestações gemelares. Examinar a correlação da área de secção transversa do cordão umbilical com o peso fetal estimado (PFE). MATERIAIS E MÉTODOS: Estudo prospectivo longitudinal envolvendo gestações gemelares dicoriônicas, não complicadas. Medidas ultrassonográficas das áreas de secção transversa do cordão umbilical (ASTCU), da veia (AVU) e artérias umbilicais (AAU), e da geleia de Wharton (AGW) foram obtidas em plano adjacente, próximo ao abdômen fetal, a cada três semanas. A correlação entre os parâmetros avaliados e a idade gestacional foi investigada por meio de modelo de regressão polinomial hierárquica, levando-se em consideração a variância segundo a idade gestacional, entre medidas obtidas em fetos da mesma gestação e, entre diferentes gestações. Para cada parâmetro estudado, foram calculados os valores correspondentes aos percentis 5, 10, 50, 90 e 95, para cada semana gestacional. RESULTADOS: Foram realizadas 334 avaliações ultrassonográficas em 44 gestações gemelares, entre 18 e 33 semanas (média: 3,8 ± 0,7 exames/gestação; intervalo médio entre exames: 3,3 ± 0,9 semanas). Os valores log-transformados de todos os parâmetros avaliados apresentaram correlação significativa (p<0,001) com a idade gestacional: Log(ASTCU) = - 2,287498 + 0,149298 x IG - 0,002302 x IG2, desvio-padrão DP = 0,113, R2 = 0,65; Log (AVU) = - 2,721487 + 0,119853 x IG - 0,001507 x IG2, DP=0,165, R2 = 0,58; Log (AAU) = - 4,223546 + 0,195454 x IG - 0,003080 x IG2, DP=0,163, R2 = 0,57; Log (AGW) = - 2,511648 + 0,157737 x IG - 0,002564 x IG2, DP=0,123, R2 = 0,55. A área de secção transversa do cordão umbilical apresentou correlação significativa com o peso fetal estimado (Log (ASTCU) = -1,602447 + 0,554502 x Log (PFE), R2 = 0,65, p < 0,001). CONCLUSÃO: Em gestações gemelares dicoriônicas, a área de secção transversa do cordão umbilical, e de seus componentes, mostram correlação positiva e significativa com a idade gestacional. A área de secção transversa do cordão umbilical também correlaciona-se significativamente com o peso fetal estimado / OBJECTIVE: To determine reference values, and examine the correlation between the cross-sectional area of the umbilical cord, and its components, with gestational age (GA) in twin pregnancies. To examine the correlation between the cross-sectional area of the umbilical cord with the estimated fetal weight (EFW). MATERIALS AND METHODS: A prospective longitudinal study involving uncomplicated dichorionic twin pregnancies. Sonographic measurements of the cross-sectional areas of the umbilical cord (UCCSA), umbilical vein (UVA) and arteries (UAA) and Wharton\'s jelly (WGA) were obtained in a plane adjacent to the fetal abdomen, every three weeks. The correlation between these parameters and gestational age was examined with hierarchical polynomial regression analysis. This modeling took into account the variance according to gestational age, fetuses within the same pregnancy and changes across different pregnancies. For each parameter, 5th, 10th, 50th, 90th and 95th centiles were calculated for each gestational week. RESULTS: 334 ultrasound scans were performed in 44 twin pregnancies, between 18 and 33 weeks (mean: 3.8 ± 0.7 scans/pregnancy, mean interval between scans: 3.3 ± 0.9 weeks). All umbilical cord log-transformed values showed a significant correlation (p < 0.001) with gestational age: Log (UCCSA) = - 2.287498 + 0.149298 x GA - 0.002302 x IG2, SD = standard deviation 0.113, R2 = 0.65, Log (UVA) = - 2.721487 + 0.119853 x GA - 0.001507 x IG2, SD = 0.165, R2 = 0.58, Log (UAA) = - 4.223546 + IG x 0.195454 - 0.003080 x IG2, SD = 0.163, R2 = 0.57, Log (WGA) = - 2.511648 + 0.157737 x GA - 0.002564 x IG2 , SD = 0.123, R2 = 0.55. The cross-sectional area of the umbilical cord also correlated significantly with the estimated fetal weight (Log (UCCSA) = -1.602447 + 0.554502 x Log (EFW), R2 = 0.65, p < 0.001). CONCLUSION: In dichorionic twin pregnancies, the cross-sectional areas of the umbilical cord, and its components, show a positive and significant correlation with gestational age. The cross-sectional area of the umbilical cord also has correlates significantly with the estimated fetal weight
8

Análise de confiabilidade estrutural de cabos umbilicais. / Analysis of structural reliability of umbilical cables.

Cordovés, Dagné de La Caridad Suñé 01 December 2008 (has links)
O presente trabalho propõe um modelo para avaliar a confiabilidade estrutural do cabo umbilical, levando em consideração os mecanismos de falha por escoamento e por fadiga mecânica. Esta análise é focada na avaliação estrutural das armaduras metálicas, dado que estes elementos suportam quase toda a carga à tração e limitam as deformações axiais da estrutura sem prejudicar significativamente a flexibilidade; desconsidera-se, portanto, o efeito estrutural do núcleo electro-óptico e das camadas polimérica interna e externa. Para esta finalidade são consideradas as tensões originadas pelos carregamentos das ondas do mar atuantes no cabo umbilical durante sua vida em serviço (plataforma semi-submersível GVA 4500 que opera na Bacia de Campos numa lâmina d água de 1000 m), assim como a geometria e as propriedades mecânicas das armaduras de tração utilizadas nos umbilicais dessas plataformas. Através da formulação de um modelo do cabo umbilical feito pelo Método dos Elementos Finitos determinou-se o histórico de tensões atuantes na estrutura, foram estimadas as funções de densidade de probabilidade da tensão estática e da tensão alternada corrigida para curto e longo prazo, as quais caracterizam o carregamento atuante provocado pelas ondas do mar. A caracterização do material é alcançada através de análise química e ensaios de tração. Finalmente, a metodologia proposta, que considera os mecanismos de falha por escoamento e por fadiga mecânica é implementada na prática. / A model to evaluate the structural reliability of the umbilical cable, taking into accounts the failure mechanism for yield strength and mechanical fatigue is proposed in this work. This analysis is focused on the structural evaluation of the metallic armors, given that these elements almost support the whole tensile load and they limit the axial deformations of the structure without harming the flexibility significantly, therefore, the structural effect of the electro-optical nucleus and the internal and external polymeric layers are not considered. For this purpose, the tensions originated by the loading of the waves of the active sea in the umbilical during its service life are considered (semi-submergible platform GVA 4500 that operates in Bacia de Campos into 1000 meters water depth), as well as the geometry and the mechanical properties of the tensile armors used in the umbilical of this platform. Through the formulation of a model for the umbilical cable, developed by the Finite Elements Method, the sequence of active tensions in the structure was determined and then the functions of density of probability of the static tension and of the alternate tension corrected for short and long period were estimated, which characterize the active loading caused by the waves of the sea. The characterization of the material is achieved through chemical analysis and tensile test. Finally, the proposed methodology, which considers the failure mechanisms by yields and mechanical fatigue is implemented in practice.
9

Modelo tridimensional em elementos finitos para a análise de cabo umbilical STU submetido ao carregamento de crushing. / Three-dimensional finite element model for the analysis of STU umbilical cable subjected to crushing load.

Guttner, William Corrêa 22 February 2016 (has links)
Este trabalho desenvolve e apresenta um modelo tridimensional em elementos finitos de um cabo umbilical do tipo STU (Steel Tube Umbilical) utilizado na extração offshore de petróleo. Tal modelo é utilizado para estudar o carregamento de crushing, que é imposto ao cabo umbilical pelas sapatas do tensionador durante o seu lançamento, de modo a obter de forma detalhada a distribuição de tensões nos componentes do núcleo, com foco nos tubos de aço utilizados para o transporte de fluidos. A metodologia empregada no desenvolvimento do modelo é descrita detalhadamente ao longo do trabalho, de forma que possa vir a ser utilizada no estudo de outras configurações de cabos umbilicais. O modelo elaborado é utilizado (i) como paradigma para a validação de um modelo bidimensional, que visa analisar o mesmo problema de forma mais simples e rápida, e (ii) para o estudo do comportamento das tensões nos tubos de aço na região de transição de entrada/saída da sapata. Na comparação entre os modelos bi e tridimensional, o trabalho conclui pela validade do modelo bidimensional na avaliação das tensões nos tubos de aço resultantes do carregamento de crushing, na região central do cabo. O estudo realizado na região de transição de entrada/saída da sapata permitiu verificar que ocorre um aumento dos níveis de tensão nos tubos de aço nessas regiões de transição, com redistribuição do campo de tensões após plastificação. / This project proposes a three-dimensional finite element model of a Steel Tube Umbilical Cable used in the offshore oil extraction. This model is used to study the crushing load imposed to the cable by the shoes of the tensioner during its installation, in order to obtain a detailed distribution of stresses in the components of the core, focusing on the steel tubes used for fluid transportation. The methodology employed in the development of the model will be fully described throughout the study, allowing to reproduce it in the analysis of different umbilical configurations. The developed model is used (i) as a paradigm for the validation of a two-dimensional model, which aims to analyze the same problem in an easier and faster manner, and (ii) to study the behavior of the stresses in the steel tubes in the entry/exit transition region of the shoe. Comparison between the two and three-dimensional models allows to conclude for the validity of the two-dimensional in evaluating the stresses in the steel tube resulting from the crushing load, in the central region of the cable. The study performed in the entry/exit transition region of the shoe has enabled do verify that there is an increase of the stress levels in the steel tubes in these transition regions, with field stress redistribution after plastification.
10

Análise de falha da camada polimérica externa de cabos umbilicais. / Failure analysis of the polymeric external layer of the umbilical cables.

Cárdenas Olivier, Nelson 14 November 2007 (has links)
No presente trabalho é proposto um método para estabelecer um critério de falha da camada polimérica externa dos cabos umbilicais usados em operações offshore. O método proposta baseia-se na determinação do incremento da quantidade de água absorvida pela camada polimérica externa do cabo devido à deterioração provocada pelos carregamentos cíclicos e o envelhecimento originados pelo meio marinho. Este método propõe a realização de um ensaio de fadiga à tração uniaxial no polímero que compõe a camada externa do cabo. O teste é feito simulando as solicitações a que é submetida a camada externa do umbilical durante os ensaios de fadiga feitos, segundo a norma API 17E, durante o processo de homologação do cabo. Além disso, se propõe fazer um ensaio de envelhecimento artificial no polímero da camada externa simulando as condições de serviço do cabo no meio marinho. Com o fim de avaliar a influência dos carregamentos cíclicos e o os agentes do meio marinho nas propriedades do polímero, são feitos ensaios de absorção de água segundo a norma ASTM D 570, ensaios de tração segundo a norma ASTM D 638, ensaios de dureza segundo a norma ASTM D 2240 e observações num microscópio eletrônico de varredura. Finalmente a partir do incremento de massa sofrido pelo polímero no ensaio de absorção de água foi estimado o dano no material da camada externa do cabo. Os resultados obtidos no trabalho mostraram que os carregamentos cíclicos e o meio marinho aceleraram o processo de degradação da camada polimérica externa do umbilical demonstrando assim a eficiência do método proposto. / In the present work is proposed a method to establish a failure criterion of the polymeric external layer of umbilical cables used in offshore operations. The proposed method is based on the determination of the increment of the quantity of absorbed water by the polymeric external layer of the cable due to deterioration caused by cyclic loads and the aging process originated by the marine environment. The method proposes to carry out a uniaxial fatigue test on the polymer that composes the external layer of the cable. This test is made simulating the cyclical deformation that the external layer is submitted in the umbilical during the fatigue test done, according to the API 17E standard, during the process of cable homologation. It is also intended to make an artificial aging test in the polymeric external layer simulating the service conditions of the cable in the marine environment. In order to evaluate of the cyclical loads and the sea set aging influence on the properties of the polymer, carry out water absorption test according to the ASTM D 570 standard, traction test according to the ASTM D 638 standard, hardness test according to the ASTM D 2240 standard and observations in an scanning electron microscopy. Finally starting from the mass increment suffered by the polymer in the water absorption test it was estimated the damage in the external layer material of the cable. The results obtained in this work showed that the cyclical loads and marine environment accelerated the degradation process of polymeric external layer of umbilical cable demonstrating the efficiency of the proposed method.

Page generated in 0.0615 seconds