• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 6
  • 4
  • 1
  • Tagged with
  • 19
  • 19
  • 8
  • 6
  • 6
  • 6
  • 6
  • 5
  • 5
  • 5
  • 5
  • 5
  • 4
  • 4
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Efficacy and mechanisms of hydrotherapy in rheumatoid arthritis

Hall, Jane January 2002 (has links)
No description available.
2

Heat Removal From A Large Scale Warm Water Storage

Kayserilioglu, Yavuz Selim 01 August 2004 (has links) (PDF)
ABSTRACT HEAT REMOVAL FROM A LARGE SCALE WARM WATER STORAGE Kayserilioglu, Yavuz Selim M.S., Department of Mechanical Engineering Supervisor: Prof. Dr. R&uuml / knettin Oskay August 2004, 88 Pages A preliminary experimental study was performed in order to investigate the charging and heat removal characteristics of a sensible heat storage. Two sets of experiments were performed at two aspect ratios. Heat removal processes of these two sets were different while the charging processes were similar. In the first set of experiments, after the charging of the storage unit with relatively warm water was complete, heat removal process was started with simple heat exchangers from different elevations within the storage while the charging of the storage unit was continued. In the second set of experiments, after the charging of the storage unit was complete, heat removal from the storage unit was started without further charging of the storage unit. Charging water was fed into the storage from the top of one side and relatively colder water was drained from the bottom of the opposite side. Internal heat exchangers were used for the heat removal. Vertical temperature profile developments during the charging and heat removal periods were investigated. Thermal stratification was observed in all experiments. Heat exchangers extracted heat from different elevations in different experiments and the trend was that more heat can be extracted in upper elevations. Comparable heat can be extracted from the same elevation of lower and higher aspect ratio. Keywords: Sensible Heat Storage, Heat Removal, Thermal Stratification, Warm Water Storage
3

Řídicí systém spalovacího systému EKOGEM / The control system of the combustion system EKOGEM

Holešovský, Petr January 2015 (has links)
This master´s thesis deals with automatic control of solid fuel boiler. Main goal of this thesis is to design control system for combustion system EKOGEM. In this thesis is introduced combustion system and its designed control. Thesis describes realization of control system and presents results, in which shows its benefits for combustion system. Control system is realized in NI LabVIEW environment.
4

Physiological Constraints on Warm-Water Habitat Site Selection and Utilization by the Florida Manatee (Trichechus manatus latirostris) in East Central Florida

Spellman, Ann 01 January 2014 (has links)
Living at the northern limits of its geographic range, the Florida manatee is particularly susceptible to cold stress-related mortality during the winter months, with most deaths occurring in the lower two-thirds of the state. Contributing to this cold stress susceptibility is the manatee's limited physiological and behavioral responses available when thermally stressed. While capable of migrating south in response to falling water temperatures, manatees must still find warm water when ambient river temperature drops below 20°C for more than a few days. This is in part due to the species low metabolic rate, limited capacity for thermogenesis, and limited ability to raise its metabolic rate. Prolonged exposure to cold temperatures may result in cold stress syndrome, which involves a number of potentially life-threatening, if not fatal physiological changes. Survival during the winter months is therefore, dependent upon the manatee's ability to balance basic physiological needs, primarily the need to forage and to obtain fresh water with the need to stay warm. When identifying which animals are most susceptible and where, analyses of statewide manatee mortality records from 1996 through 2011 (n = 823) indicated that, size and location matter. Medium to large-sized calves accounted for the majority of documented death from cold stress (46.6%), while subadults and small calves were the least represented size classes (14.3 % and 9.5%, respectively). Adults slightly outnumbered subadults (15.8%). Males outnumbered females in all size classes but gender differences were not statistically significant. With regards to location, two areas of the state, the southwest and central east coasts showed the highest incidents of cold stress-related mortality. Both are regions with no primary, natural warm-water springs and whose principal warm-water refugia are power plant effluents. Brevard County on the central east coast is the area most at risk during cold weather events accounting for more than 25% of all cold stress deaths statewide. Warm-water sites within this region are few and relatively underrepresented in the literature in an area well-studied in terms of manatee abundance and distribution relative to the operational power plant. Results from cold stress data analyses emphasize the importance of identifying and characterizing the physical attributes of both known and suspected secondary warm-sites used by manatees in this region for both long and short term protection of the species, and its critical habitat. Three locations within Brevard County identified as passive thermal basins (PTBs), and classified as secondary warm-water sites, have been documented supporting in excess of 100 manatees on numerous occasions, and during winters of varying severity. Unique in physical appearance, distance to forage, hydrology including thermal profiles, and when it was used by manatees, each site challenged the accepted definitions and criteria of what constitutes an acceptable and appropriate warm-water site. Through analyses of photo-identification records, site fidelity at two of these warm-water sites, the Berkeley Canal and the Desoto Canal, was established for a minimum of 20 highly identifiable animals, 15 of which used adjacent sites within the same year, and 6 that used both sites but during different years. Observations of daily use patterns within the sites supported optimization of thermoregulation through adjustments in both vertical and horizontal movement, the latter of which seemed to follow the path of the sun. Manatees using the sites also made use of bottom sediment presumably to stay warm at all three locations. Temperature data indicated that water temperatures monitored in the sediment at secondary sites were some of the highest in the county. The predictable movements during all but the coldest weather fronts indicated that manatees utilized these sites during the early morning and afternoon hours when ambient river temperatures were coldest, gradually returning to the river to feed as ambient temperatures began to rise later in the afternoon. The availability of PTBs in proximity to primary warm-water sites within the region may provide an important component needed for manatees to successfully balance the need to forage with the need to stay warm by providing a network that allows for more efficient foraging while reducing exposure to sub-critical ambient river temperatures. The challenge of balancing the need to forage and to maintain homeostasis in the face of thermal stress is complex. This complexity was best approached and better understood through use of a manatee energetics model. The model was designed to facilitate simulation of an unlimited number of different case scenarios involving the exposure of virtually created manatees to a variety of winter conditions as might be experienced by real manatees in a natural system. Sixty-four different simulations were run using six virtual manatees of differing ages, gender, physical parameters, and knowledge of warm-water sites. Simulations were conducted using actual winter water temperature data from Brevard secondary sites and the ambient river from both a mild and a severe winter season. Outcomes, measured as changes in physical parameters indicative of body condition (i.e. mass, percent body fat, blubber depth, girths, etc.), showed that all else being equal, calves in the 2 year-old range fared poorly in all scenarios when compared to individuals of larger size. Subadults fared better than larger adults. This outcome illustrates the complex relationship between size, energy requirements and the synergistic effects of body mass, body fat and blubber thickness on SA:V ratio. Model outcomes agree closely with manatee cold stress mortality analyses predicting that medium to large-sized calves are most susceptible to CS, followed by adults, then subadults. Because all models are simplifications of complex systems, the manatee energetics model is not without its flaws and limitations. The current version of the model could not predict the point at which cold stress mortality would occur. However, a cold stress warning system incorporated into the design alerts the user if potential CSS is likely based on changing physical parameters. Another limitation was the inability of the model to account for the behavioral plasticity of individual subjects since virtual manatees respond to water temperatures based on the user defined rules. A number of additional limitations related to gaps in existing manatee data the gaps were identified and defined. Despite these gaps, the model is designed to allow for incorporation of additional interactions, feedback loops and relevant data as it becomes available and as additional physiological interactions and energy requirements are more clearly defined. Sensitivity analyses, a feature of the model that allowed for modifications in a number of physical as well as environmental parameters, provided an otherwise unlikely opportunity to see how incremental changes in input values, specifically the starting values for mass, percent body fat and blubber depth affected the model's outcome. Ultimately the goal of the model was to facilitate a better understanding of complex relationships by challenging our preconceived understanding of the manatee and its environment.
5

Energy analysis between traditional hot water circulation system and an innovative pipe-in-pipe system

Abellán Guallarte, Alejandro January 2022 (has links)
We are at a time when energy efficiency and the reduction in the use of non-renewable energy is an important objective in all aspects and will continue to be so, therefore it is necessary to try to reduce energy and heat losses in the systems used in homes and, in particular, in the domestic hot water (DHW) system. This study aims to find out the advantages and disadvantages of an innovative pipe-in-pipe (PIP) system for DHW circulation with respect to the conventional system of two separate pipes. Previous studies have shown that DHW circulation is indeed an important point of energy losses in the home and that it is possible to reduce these losses by using the innovative system under study. The properties and coefficients defining the heat transfer system have been obtained for both the traditional and innovative systems by using empirical equations and iterative processes, indicating a 32% reduction in heat losses in favour of the pipe-in-pipe system. However, this result has been obtained in a kind of case study, using some simplifying assumptions, needed to accomplish to work within limited time. So the result could vary if a somewhat different system is studied, which is why it is necessary to carry out further studies and research on this subject in order optimize DHW systems in buildings.
6

The Effects of a New Bridge on Manatee (Trichechus manatus latirostris) Use of the FPL Discharge Canal at Port Everglades, Florida

Viragh, Brea 01 July 2012 (has links)
The Florida manatee (Trichechus manatus latirostris) is an endangered species that migrates to warm water refuges such as natural springs or power plant effluents during the winter months to escape cold water. The Florida Power and Light (FPL) discharge canal in Port Everglades, Ft. Lauderdale, FL., is utilized as a refuge by overwintering manatees. Construction of a new bridge over the FPL effluent canal had a potential effect on manatee usage of the canal. Discharge is often 10-15° C warmer in the winter season than the surrounding waters of the Intracoastal Waterway. Previous data, including age class and cow/calf abundance from pre-bridge winters (2004-2009), were compared with data from winter 2010, during bridge construction and winter 2011, postbridge construction. No manatees were present at the survey sites during winter until surface water temperatures fell below 22° C. Although monthly mean surface water temperatures were not statistically different between 2008-2009, 2009-2010, and 2010-2011 (21.9±0.4° C, 21.8±1.8° C and 21.4±0.6° C respectively), manatee abundance did vary. 2008-2009 had higher monthly mean numbers of manatees per survey from December through March (29.7, 27.3, 48.1, 2 respectively) than 2009-2010 (0, 30, 10.7, 5 respectively) and 2010-2011 (18.7, 6.7, 0.1, 0 respectively). A Poisson distribution analysis showed a significant difference in adult manatee counts among the study years (α < 0.05). No significant differences were found for juveniles and calves. While I cannot decisively state that bridge construction reduced the number of overwintering adult manatees during 2010, there appears to be the potential for an effect.
7

Návrh tepelného okruhu teplárny s kogenerační jednotkou 1600kWe / Heat layout of heating power plant with cogeneration unit 1600kWe

Buřil, Tomáš January 2013 (has links)
Main target of this master´s thesis is a projection of a thermal circuit of a heating plant, which uses waste heat of a cogeneration unit with power of 1600 kWe. Electric power of a cogeneration unit is supplemented with an electric power produced from a waste heat. All heat is further used for heating in a warm water heating system. Within this thesis are executed projections of a thermal circuit of a heating plant, choice of particular devices, determination of a thermal power of devices and also determination of conditions of particular heat – transferring substances. Furthermore, design of particular devices is made, mainly for basic dimensions and heat transfer.
8

Diurnal Movements and Site Fidelity of the Florida Manatee, Trichechus manatus latirostris, in Fort Lauderdale, FL.

Walsh, Kym 11 January 2010 (has links)
The diurnal movements of Florida manatees (Trichechus manatus latirostris) in warmwater refugia are poorly understood and these may prove critical in accurately estimating populations of these animals. Previous studies indicate that manatee populations in such refuges in Tampa Bay, FL, peak mid-day and decline towards evening when the animals leave to forage. This trend suggests that variation in the timing of aerial manatee population surveys may hamper accurate estimation of the true population size. Aerial survey counts are known to underestimate population size, yet the extent of the underestimation may be greater than expected. In this study data were collected over three seasons from land-based surveys monitoring the presence of manatees in the effluent canal from the Florida Power and Light electricity generating facility in Port Everglades, FL between 15 November and 31 March. My findings indicated there was no significant difference in the number of manatees observed during the seasons studied despite a significant difference in ambient water temperatures. There was a significant correlation in the number of manatees an observer can expect to see based on time of day with the trend indicating there are higher numbers of observable manatees in the morning compared to later in the day. This suggests that early morning aerial counts will more accurately reflect true manatee presence in the Port Everglades power plant. Photographs of individual manatees yielded a total of 58 animals with unique scaring patterns.
9

Energiprisstrukturens inverkan på val av energieffektiviseringsåtgärder : En analys av trender inom el- och fjärrvärmeprissättning och dess inverkan på effektiviseringsåtgärder i bostadsbeståndet

Wallenbert, Henrik January 2017 (has links)
The purpose of this examination is to see how energy efficiency measures affect peak loads in multifamily buildings. In addition, how much of an energy share warm water has in peak loads. The Swedish building sector represents 40 % of all energy used. The thesis was restricted to multifamily buildings, which is dominated by district heating. The most common energy measures to save peak cost and reduce peak loads that are focus in this thesis work, e.g. changing windows, isolate walls and attics but also lowering indoor temperature. It was assumed in the thesis that the cost of peak loads will increase in the future and therefore the choice of energy efficiency measures is important. The calculations to determine the effectiveness of the energy measures where done by using hourly temperature data from the year 2014 in combination with, known investment costs for each energy measure. The only measures that went with profit over a 40-year period was the attics isolation and lower indoor temperature. The highest peak load savings in heating was the change of windows and wall isolation, but the investment cost was too high to gain a profit. The conclusion is that the best energy efficiency measures are attic isolation and lower indoor temperature because of its low investment cost and quick payback time, but also effective at lowering peak load by reducing the temperature difference between outdoor and indoor temperature in multifamily buildings. The analysis of warm water energy's share of the peak loads varied much between the 15 given multifamily buildings, where a base load and a peak load where compared. The result was between 10-50 % were the difference between the buildings warm water energy share off the peak loads. It where concluded that a standard value of 20 % would give much inaccuracy in determining the warm water share. It is therefore, suggested to use this method to determine the warm water share of the hourly peak load. / I detta arbete har syftet varit att hitta de vanligaste energieffektiviseringsåtgärderna som görs idag i det svenska bostadsbeståndet. Energieffektiviseringsåtgärderna påverkar effekttoppar i flerbostadshus och har undersökts. Om det antas att energiprisstrukturen går mot en mer effektbaserad taxa kan åtgärderna få större påverkan på energipriset i framtiden. I arbetet har varmvattnets andel av timeffekttoppar undersökts, med stöd av energianvändningsdata från 15 anonymiserade flerbostadshus med fjärrvärme. Energianvändningen i bostadsbeståndet står för ca 40 % av Sveriges energianvändning. Det ställs då krav på de lågenergihus som byggs idag och vid renovering av hus att möta Sveriges som såväl EU 2020 målet att minska energianvändningen i bostäder genom att implementera energieffektiviseringsåtgärder. De vanligaste energieffektiviseringsåtgärderna i flerbostadshus har varit isolering av väggar och vind, installation av energiglas och frånluftssystem med värmeåtervinning. En sänkt inomhus temperatur har även medtagits. För fastighetsägare av flerbostadshus, där energianvändning för uppvärmning och varmvatten domineras av fjärrvärme är prisutvecklingen viktig. Om i framtiden ett antagande görs att el och fjärrvärmepriset övergår från en energibaserad taxa kr/kWh till en mer effektbaserad taxa kr/kW där kunden betalar för de högsta effekttopparna under ett år. I denna studie redovisas det när effekttoppar uppstår och vilka energieffektiviseringsåtgärder som påverkar effekttopparna i flerbostadshus. De högsta effekttopparna uppstår oftast under vinterårstiden då uppvärmningsbehovet är störst. I ett framtaget typbostadshus där de valda energiåtgärderna beräknades, det visade sig att energiglas minskar effektbehovet och effektpriset mest, därefter väggisolering med mineralull. Emellertid ger energiglas och väggisolerings åtgärderna ger förluster i lönsamhetsberäkningen. Det skiljer sig från tilläggsisolering med mineralull av vinden och sänkt inomhus temperatur som har en investerings vinst över en 40 års period. I beräkningarna användes temperaturdata från år 2012 både på typhuset innan och efter implementerad åtgärd.En viktig parameter vid minskning av uppvärmningsbehovet är U-värdet. Tilläggsisolering av vind samt sänkt temperatur är de åtgärder som rekommenderas då båda påverkar effektbehovet och ger en lönsam investering. Åtgärd vid fönster och väggar minskar dock uppvärmningsbehovet mest men ger en olönsam ekonomisk investering. Varmvattenandelen av den högsta timeffekttoppen över året togs fram genom att jämföra baslasten och effekttoppen under dagen då effektbehovet är som högst. Resultatet visade att varmvattenandelen av effekttoppen tycks variera mellan ca 10- 50 %. Varmvattenandelen av effekttoppen varierar stort och därför föreslås användningen av metoden i detta examensarbete istället för ett schablonvärde på 20 % vid undersökning av varmvattenandelen av timeffekttoppen.
10

Differential Use of Two Warm-Water Effluents by the Florida Manatee (Trichechus manatus latirostris) and Temporal Distributions throughout Broward County, Florida

Eldredge, Laura F 27 July 2017 (has links)
The threatened Florida manatee (Trichechus manatus latirostris) migrates seasonally to warm-water refugia throughout the state of Florida due to metabolic requirements from low thermal conductance. Broward County’s two power plant refugia, Port Everglades (PEP) and Lauderdale (LPP), are known heavily-utilized aggregation sites for the Atlantic sub-population. Broward County collected relative abundance counts via aerial surveys from 2004–2013 siting 31,418 manatees during 169 surveys within 18 defined waterway zones. Counts during manatee wintering seasons were significantly different from January 2005-March 2008 and November 2008-March 2013, likely related to flight path and frequency standardization. Mean percentage of adults (90.12%) to calves (9.88%) demonstrates a higher usage by cow-calf pairs than other aggregation sites. Counts of manatees traveling south to Miami-Dade County comprised only 0.83% of all aerial counts, contrary to the theory of the extensive usage of Biscayne Bay foraging grounds. The LPP zone had 57.21% of all manatees with Port Everglades Inlet zone accounting for 23.88% and the South Fork New River zone with 5.95%. This study provided a baseline for pre-construction distributions prior to Port Everglades plant reenergization. With PEP construction now finished and LPP planned for reenergization in the next 10 years, monitoring data studies be compared to these baseline data to better assess the impact of the disruption of Broward County’s main refugia sources.

Page generated in 0.0809 seconds