• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 358
  • 158
  • 58
  • 39
  • 7
  • 6
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 3
  • 3
  • Tagged with
  • 742
  • 742
  • 146
  • 140
  • 82
  • 68
  • 67
  • 54
  • 53
  • 39
  • 37
  • 36
  • 36
  • 35
  • 34
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
301

Determination of effective dose and entrance skin dose from dose area product values for barium studies in adult patients at a large tertiary hospital in the Western Cape

Peters, Nazlea Behardien January 2017 (has links)
Thesis (MSc (Radiography))--Cape Peninsula University of Technology, 2018. / Background and objectives The issue of patient doses received during fluoroscopy procedures, raised concerns for the researcher, as there may have been probable past skin injuries or deterministic injuries that may not have been documented. Amongst the radiology staff, there was very little understanding of what the actual dose area product (DAP) value means in real terms of effective dose and entrance skin dose. The aims of the study were to: i) Measure the radiation doses received by the patient and determine a simple means of defining the DAP value to the radiographer in terms of the dose received by the patient. ii) Determine the effective dose, entrance skin dose and the relationship with the DAP value to assist with developing a conversion co-efficient for dose indicators. Method Direct radiation dose measurements can be obtained through DAP meters attached to the diagnostic equipment, but the DAP value is not an direct indication of the effective dose received by the patient. The DAP values captured from the DICOM header information for barium fluoroscopic procedures at a large tertiary was analysed and Diagnostic Reference levels (DRL) were determined for barium swallow, meal and enema procedures. The effective and skin doses were calculated by means of the Monte Carlo program. The results were compared to published values. The relationship between the entrance skin dose and the DAP value was determined and conversion factors were calculated. Results Correlation between the DAP and entrance skin dose and comparative 75th percentile threshold values were determined for barium swallow (BaS), barium meal (BaM) and barium enema (BaE) procedures. Effective to DAP conversation factors for BaS, BaM and BaE are 0.19, 0.26 and 0.60 respectively and 0.15, 0.11 and 0.14 for entrance skin to DAP. Conclusion The the research showed the relationship between the effective dose, entrance skin dose and DAP value and a simple, practical and applicable explanation of the DAP value by means of conversion factors.
302

Espectroscopia de raios X na faixa de energia de 5 a 200 keV, utilizando fotodiodos PIN de silício / X-ray spectroscopy in the energy range from 5 to 200 keV, using silicon PIN photodiodes

Marcia de Carvalho Silva 21 February 2001 (has links)
O conhecimento da distribuição espectral da radiação X emitida por unidades de radiodiagnóstico fornece importantes informações, que podem ser aplicadas aos programas de Garantia de Qualidade e de Proteção Radiológica. Detectores que utilizam fotodiodos PIN de Si como ponta de prova vêm sendo utilizados nos últimos anos devido, principalmente, ao seu baixo custo e por trabalharem a temperatura ambiente, não precisando dos tanques de nitrogênio líquido necessários em detectores de Ge e Si(Li). Embora, a princípio, os fotodiodos PIN tenham uma pior resolução, quando comparada com os detectores de Ge, ela é suficientemente boa para a maior parte das aplicações em radiodiagnóstico. Além disso, o desenvolvimento de sistemas refrigerados termoelétricamente e de pré-amplificadores de baixo ruído têm feito com que os fotodiodos PIN cheguem a resoluções comparáveis às do Ge. Este trabalho visa estabelecer as propriedades de detectores constituídos por fotodiodos PIN de Si e desenvolver o processo de correção dos espectros brutos para a eficiência do detector e outros fatores pertinentes, a fim de se obter o espectro real emitido por equipamentos de radiodiagnóstico. Espectros de radiação de equipamentos de radiodiagnóstico obtidos experimentalmente foram comparados com espectros teóricos calculados a partir de um modelo semi-empírico. Além disso, foram obtidos espectros de radiação emitidos por unidades de mamografia, espalhados por um objeto simulador de mama. Como aplicação direta dos espectros medidos experimentalmente, foram desenvolvidas metodologias para a determinação da tensão aceleradora de tubos de Raios X (kVp), para fins de calibração de medidores de kVp, e da camada semi-redutora (CSR) dos feixes de interesse. / Knowledge of the spectral distribution of radiation emitted by radiodiagnostic units provides important information, which can be applied to the Quality Assurance and Radiological Protection programs. Detectors which utilize Silicon PIN Photodiodes have been increasingly used in recent years, due to their low cost and being worked with at room temperature, the liquid nitrogen containers used with Ge and Si(Li) detectors not being necessary. Although, initially, the PIN photodiodes have a poorer energy resolution, as compared with Ge detectors, it\'s good enough for most purposes. Moreover, the development of thermoelectrically cooled systems and low noise level pre-amplifiers have resulted in PIN photodiodes achieving comparable resolutions to Ge ones. This work seeks to establish the properties of detectors made with Silicon PIN photodiodes and to develop the correctional process of the raw specffa both for the efficiency of the detector and other relevant factors, with the aim of obtaining the true spectrum emitted by radiodiagnostic equipment. The radiation spectra of radiodiagnostic equipment experimentally obtained were compared with theoretical spectra calculated from a semi-empirical model. Furthermore, mammography x-ray spectra scattered by a breast simulator were obtained. As a direct application of these experimentally measured spectra, methodologies were developed to determine the peak kilovoltage (kvp) of X-Ray tubes, to be able to calibrate kVp meters, and the half-value layer (HW) of the beams of interest.
303

O efeito da radiação X e do alendronato de sódio na microarquitetura óssea e no reparo ósseo de ratas com deficiência de estrogênio / X-ray effects and sodium alendronate on bone microarchitecture and bone repair in rats with estrogen deficiency

Gomes, Carolina Cintra, 1979- 05 March 2013 (has links)
Orientador: Solange Maria de Almeida / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-22T22:27:04Z (GMT). No. of bitstreams: 1 Gomes_CarolinaCintra_D.pdf: 2371162 bytes, checksum: a83060f2fb962062c6ec3fa55ea99748 (MD5) Previous issue date: 2013 / Resumo: Nesse estudo teve-se como objetivo avaliar o efeito do alendronato de sódio e de 15 Gy de radiação X no processo de reparação tecidual de defeitos ósseos e na microarquitetura óssea em ratas com deficiência de estrogênio. Foram utilizadas quarenta ratas (Rattus Norvegicus, Albinus Wistar), adultas, com idade de 90 dias. Os animais foram divididos aleatoriamente nos seguintes grupos: Controle ovariectomizado, Ovariectomizado / Alendronato, Ovariectomizado / Irradiado, Ovariectomizado / Alendronato / Irradiado. O alendronato (5 mg/kg corpóreo) foi administrado durante quatro semanas nos grupos Ovariectomizado / Alendronato e Ovariectomizado / Alendronato/ Irradiado. Doze dias após a terapêutica com alendronato de sódio um defeito ósseo foi confeccionado na tíbia esquerda dos animais. Três dias após, os grupos Ovariectomizado /Irradiado e Ovariectomizado / Alendronato / Irradiado tiveram os membros posteriores irradiados com 15 Gy de radiação X. As eutanásias ocorreram 10 e 33 dias após a confecção dos defeitos ósseos. O reparo ósseo foi analisado por histomorfometria e a microarquitetura óssea analisada por micro-TC. Em relação ao processo de reparação tecidual dos defeitos ósseos, a radiação X e o alendronato não apresentaram efeitos significativos (p > 0,05). Em relação à microarquitetura óssea, a radiação X aumentou a espessura da cortical óssea no tempo de 10 dias (p < 0,05); e no tempo de 33 dias, diminuiu o número de trabéculas por unidade de comprimento e aumentou a distância média entre as trabéculas (p < 0,05); o alendronato de sódio inibiu o efeito deletério da radiação X evitando o aumento da distância entre as trabéculas e a redução do número de trabéculas por unidade de comprimento no tempo de trinta e três dias (p < 0,05). Nessas condições experimentais conclui-se que a radiação X apresentou um efeito deletério sobre a microarquitetura óssea e o alendronato de sódio preservou o tecido ósseo submetido à radiação X / Abstract: The aim of the present study was to evaluate the effect of sodium alendronate in the process of tissue repair of bone defects, artificially produced in estrogen-compromised rats irradiated with 15 Gy. We selected forty female adults rats (Rattus norvegicus, Wistar Albinus), aged 90 days. The animals were randomly divided into the following groups: ovariectomized; ovariectomized-alendronate; ovariectomized-irradiated; and ovariectomized-alendronate-irradiated. Sodium alendronate (5 mg/kg) was administered three times a week, for four weeks, in ovariectomized-alendronate and ovariectomized-alendronate-irradiated groups. Twelve days after the end of treatment with alendronate, a bone defect was created in animals' left tibia. Three days later, the posterior legs of ovariectomized-irradiated and ovariectomized-alendronate-irradiated group animals were irradiated with 15 Gy. The euthanasias occurred 10 and 33 days after bone defects creation. The presence of bone repair was analyzed by histomorphometry, and the bone microarchitecture was analyzed by micro computed tomography. In relationship to the process of tissue repair on osseous defects, the X radiation and the alendronate do not represent significant effects (p > 0,05). In relationship to the osseous microstructure, the X radiation increased the thickness of the cortical bone in the time of 10 days (p < 0,05); decreased the number of trabeculae per unit of length and increased the medium distance between the trabeculae in the time of 33 days (p < 0,05); the sodium alendronate inhibited the deleterious effect of the X radiation avoiding the increase in distance between the trabeculae and reduced the number of trabeculae per unit of length in the time of 33 days (p < 0,05). In these experimental conditions it is concluded that the radiation X had a deleterious effect on bone microarchitecture and alendronate sodium preserved bone tissue subjected to the radiation X / Doutorado / Radiologia Odontologica / Doutora em Radiologia Odontológica
304

A physical model for the variability properties of X-ray binaries

Ingram, Adam Russell January 2012 (has links)
Emission from X-ray binaries is variable on a wide range of timescales. On long timescales, changes in mass accretion rate drive changes in spectral state. There is also rapid variability, the power spectrum of which consists of a low frequency quasi-periodic oscillation (QPO) superimposed on a broad band noise continuum. Here I investigate a model intended to quantitatively explain the observed spectral and variability properties. I consider a truncated disc geometry whereby the inner regions of an optically thick, geometrically thin accretion disc evaporate to form an optically thin, large scale height accretion flow. The QPO is driven by Lense-Thirring precession of the entire hot flow and the broad band noise is due to fluctuations in mass accretion rate which propagate towards the central object. Mass conservation ties these two processes together, enabling me to define a model for the QPO and broad band noise which uses only one set of parameters. I am thus able fit the model to data. The accretion rate fluctuations drive fluctuations in the precession frequency, giving rise to a quasi-periodic oscillation rather than a pure periodicity. The model thus predicts recent observations which show the QPO frequency to correlate with flux on short timescales. I then investigate a more unique model prediction. As the flow precesses, the patch of the disc preferentially illuminated by the flow rotates such that a non face on observer sees a quasi-periodic shift between blue and red shift in the iron K alpha line. An observation of such an effect would constitute excellent evidence for the model.
305

The crystal structure of caesium permanganate by x-ray diffraction

Nassimbeni, L R January 1963 (has links)
The crystal structure of caesium permanganate has been determined. CsMn0₄ crystallises in the orthorhombic space group Pnma. There are four molecules per unit cell with a = 10.0692 Å, b = 5.8080 Å, c = 7.9470 Å. The structure was determined by Fourier syntheses on the (010) and (001) projections and refined by two-dimensional difference syntheses. The structure is similar to that of KMn0₄. The manganese is surrounded by four oxygen atoms at an average distance of 1.629 Å arranged in a slightly distorted tetrahedron. The caesium is surrounded by eight manganese atoms at an average distance of 4.381 Å.
306

Die ontwikkeling van apparaat en analitiese tegnieke vir gekoppelde X-straaldiffraksie-ontledings van flodders

Clark, Wilma 02 April 2014 (has links)
M.Sc. (Geology) / This study involves the quantitative analysis of fluorspar-containing slurries by two X-ray diffraction methods, whereby these two methods of on-stream analysis are compared. The first method involves a single counter with a diffracted beam monochromator, and the second method involves a fixed geometry with an incident beam monochromator. The second method is a cheaper and more robust apparatus, which can withstand the harsh environment of the flotation plants. A new algorithm was developed for a more accurate calibration method. Programmes for calibration, recalibration and measuring of unknown samples were developed. The measuring apparatus was interfaced with a microcomputer for computerised operation of the system. Results from both methods were comparable, with more accurate results obtained for the feed and tailings than for the concentrate samples. The single detector apparatus can thus be replaced by the fixed geometry model, which is less expensive and more robust.
307

Characterisation by X-ray diffraction of naturally occurring polycrystalline diamond samples from different origins

Moipolai, Tshegofatso Bridgette 12 November 2015 (has links)
M.Phil. (Energy Studies) / Non-destructive investigations of unusual natural polycrystalline diamond samples are reported. The samples originate from various international locations discovered in soils and sediments and may have been formed by di erent mechanisms which are the subject of debate. Analysis techniques include scanning electron microscopy, with energy dispersive spectroscopy and X-ray di raction. Sample composition, structure and surface stresses were investigated. The samples (two Egyptian nodules, two Brazillian carbonados, two Venetian ballas diamonds and a polycrystalline diamond compact sample consisting of a polycrystalline diamond layer sintered onto a Co-cemented tungsten carbide support) are cubic diamonds, with varying amounts of minority phases. In most cases the minority phases could not be identi ed unambiguously due to their low intensities and the overlap of Bragg peaks. The Egyptian nodule samples in particular showed a large presence of oxygen that could not be linked to speci c metal oxides. The Ballas samples had the lowest impurity content. Using a Rietveld based quanti cation analysis, the crystalline cubic diamond contents were determined respectively as 99 wt.%, 98 wt.% and 76 wt.% in the Ballas, Brazilian carbonado and Egyptian nodule samples. A signi cant result from this study is the substantial inhomogeneous peak broadening observed in the X-ray diffraction patterns of the Egyptian samples. This is indicative of the presence of nano-crystalline diamond grains in addition to substantial mechanical deformation with extensive accumulation of dislocations and crystalline defects. These observations are supportive of a recently proposed impact mechanism for their formation.
308

Decay of some excited nuclear states

Thomas, M. F. January 1965 (has links)
No description available.
309

X-ray diffraction study of metal to metal bonds

Mannan, Kh. A. I. F. Mafizul January 1965 (has links)
No description available.
310

Determination of the crystal structure of three organic compounds by X-ray diffraction

Schaffrin, Roger Michael January 1970 (has links)
The crystal structure of dibenzothiophene has been determined by X-ray diffraction. Mo-Kα [subscript omitted] scintillation counter data were used for this analysis; the sulfur atom position was determined by means of a Patterson function; the carbon atoms were located from a Fourier synthesis, and the hydrogen atoms, from a difference synthesis. Refinement of positional and thermal parameters was by least-squares methods. The molecule is slightly folded, the dihedral angles between the five-membered ring and the six-membered rings being 0.4° and 1.2°. The bond distances and valency angles are similar to those in related molecules. The C-S bond length is 1.740 A, and the C-S-C angle is 91.5°. The crystal structure of DL-ornithine hydrobromide has been determined by means of visual Cu-Kα [subscript omitted] data. The bromine ion position was found by Patterson methods; carbon, nitrogen, and oxygen atoms were located on Fourier summations and the hydrogen atoms, on a difference synthesis. The positional and thermal parameters were refined by least-squares. The ornithine molecule is a zwitterion, with both nitrogens accepting protons. The mean bond distances are C-0, 1.249 A; C-N, 1.469 A; C-C, 1.532 A. The structure is held together by a system of N—H …… 0 (2.84, 2.84, 2.89 A) and N—H…..Br (3.29, 3.36,.3.46 A) hydrogen bonds. The crystal and molecular structure of histamine diphosphate monohydrate has been determined with scintillation counter Mo-Kα [subscript omitted] data. The positions of the phosphorus atoms were determined by Patterson methods; the carbon, nitrogen and oxygen atoms were located by means Fourier syntheses; the hydrogen atoms were found on a difference synthesis. The thermal and positional parameters were refined by least-squares. The atoms of this histamine cation lie in two almost perpendicular planes, the plane of the imidazole ring and that of the side chain. The bond lengths and angles are similar to the corresponding values in histidine hydrochloride monohydrate. The dimensions of the two P0₂(OH) ₂⁻ ions are P-0 1.51 A, P-OH 1.57 A, O-P-0 115.5°, and HO-P-OH 107.0°. The most important feature of the packing is a complex system of 0-H.....0 and N-H...0 hydrogen bonds. / Science, Faculty of / Chemistry, Department of / Graduate

Page generated in 0.0324 seconds