• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 148
  • 126
  • 29
  • 17
  • 10
  • 9
  • 6
  • 6
  • 6
  • 6
  • 6
  • 6
  • 3
  • 3
  • 3
  • Tagged with
  • 442
  • 442
  • 153
  • 140
  • 125
  • 112
  • 104
  • 68
  • 66
  • 64
  • 64
  • 63
  • 59
  • 58
  • 48
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
371

Simulação do co-tratamento de resíduo de tanque séptico em estação de tratamento de esgoto doméstico

Pistorello, Josiane January 2018 (has links)
O presente trabalho avaliou a possibilidade de receber e tratar resíduo de tanques sépticos num sistema dimensionado para tratar esgoto doméstico. Neste sentido, o objetivo deste estudo foi avaliar o co-tratamento deste resíduo numa estação de tratamento de esgoto composta por processo de lodos ativados. Para a realização desta avaliação utilizou-se o modelo matemático ASM1 e o software WRc Stoat 5.0. O modelo ASM1 descreve a remoção de matéria orgânica carbonácea, a nitrificação e a desnitrificação. Para atender ao objetivo proposto, foram realizadas simulações de quatro grupo de cenários, sendo que em cada grupo a ETE operava com uma vazão fixa e foi alterada a parcela de resíduo de tanque séptico a ser tratada no sistema. Para a realização das simulações, previamente realizou-se a estruturação do modelo matemático ao sistema de tratamento selecionado, ajustes dos coeficientes estequiométricos e parâmetros cinéticos e determinaram-se as concentrações de entrada e o fracionamento da DQO e do nitrogênio para o esgoto bruto e para o resíduo de tanque séptico. As simulações geraram como resultado a possibilidade de, num sistema dimensionado para uma vazão média de 180 m3/h e operado com uma vazão de 45 m3/h de esgoto doméstico receber 4,3 m3/h de resíduo de tanque séptico sem comprometer os padrões de lançamento. Já, no caso da mesma ETE operando com 90 m3/h, 135 m3/h e 162 m3/h, as parcelas possíveis de serem recebidas de resíduo de tanque séptico e concomitantemente atendendo aos padrões de lançamento definidos na legislação foram 3,6 m3/h, 3,3 m3/h e 2,9 m3/h. Os resultados obtidos permitem concluir que é viável co-tratar resíduo de tanque séptico com o esgoto doméstico e ao mesmo tempo atender aos padrões de lançamento definidos na legislação, desde que respeitados os fatores limitantes e as cargas máximas. O recebimento e o tratamento do resíduo de tanque séptico em sistemas projetados para esgoto doméstico mostram-se como práticas que podem ser implantados na gestão dos sistemas de esgotamento sanitário. Esta aplicação poderia contribuir para ampliar a correta destinação dos esgotos e consequentemente com a melhoria dos índices de atendimento do esgotamento sanitário. / The present work evaluated the possibility of receiving and treating septic tank residue in a system designed to treat domestic sewage. Therefore, the objective of this study was to evaluate the co-treatment of this residue in a sewage treatment plant with an activated sludge process. The ASM1 model and software WRc Stoat 5.0 were used to perform this evaluation. The ASM1 model describes the removal of carbonaceous organic matter, nitrification and denitrification processes. To attend the proposed objective, simulations of four scenarios group were realized and in each group the system operated with a fixed flow and was changed the portion of septic tank residue. Before running the simulations, the mathematical model was structured to the selected treatment system, adjustments of the stoichiometric coefficients and kinetic parameters and were determined the inputs and fractionations concentration of the COD and nitrogen for the sewage and the septic tank residue. The simulation results show that is possible, in a system designed for an average flow of 180 m3/h and underloaded with a domestic sewage flow of 45 m3/h to receive 4.3 m3/h of septic tank residue without compromising the standards. For systems operating at 90 m3/h, 135 m3/h and 162 m3/h, the possible parcels to be received from septic tank residue without compromising standards defined in the legislation were, respectively, 3.6 m3/h, 3.3 m3/h and 2.9 m3/h. The results allow the conclusion that it is feasible to co-treat septic tank residue with domestic sewage and at the same time respect the standards defined in the legislation, once the limiting flowrates and maximum loads are respected. The acceptance and treatment of septic tank residue in systems designed for domestic sewage are practices that can be implemented in the management of sanitary sewage systems. That can be enplaned to improve the management of sewage systems, therefore, expanding the correct destination of wastewater and consequently contribute to the improvement of sanitary sewage index.
372

Integração entre os processos foto Fenton e lodo ativado no tratamento de efluentes contendo compostos orgânicos recalcitrantes. / Integration of photo-Fenton and activated sludge processes on the treatment of wastewater containing recalcitrant organic compounds.

Fernando Carlos Nascimento Sassano 24 October 2008 (has links)
O Fenol e compostos fenolicos foram classificados como poluentes primarios pela Environmental Protection Agency (EPA USA). Eles sao geralmente encontrados em efluentes industriais como: poupa e papel; madeireiras; plasticos e polimeros sinteticos; farmaceuticos, pesticidas, oleo e petroquimicas. Os tratamentos de agua convencionais tem mostrado ineficiencia em altas concentracoes de fenol. Este trabalho visa o tratamento de solucao aquosa de fenol via Processos Oxidativos Avancados (POAs) com o objetivo de aumentar a biodegradabilidade possibilitando a aplicacao de um processo convencional (lodos ativados) como pos-tratamento. O pre-tratamento e usado para modificar a estrutura do fenol levando-o a seus subprodutos como substancias aromaticas e acidos carboxilicos. Os experimentos mostraram a eficiencia do pre-tratamento atraves do parametro de biodegradabilidade (DBO5/DQO) apresentando 0,19 em 30 min de reacao foto- Fenton, com concentracao inicial de fenol de 1000 mg.L-1 de Carbono Organico Total (TOC), 1 mmol.L-1 de FeSO4 e 100 mmol.L-1 de H2O2, dosado durante 2 horas de reacao. Apos pre-tratada fotoquimicamente, esta mesma solucao foi utilizada como fonte de carbono em um sistema continuo de lodos ativados para remocao da materia organica residual, apresentando reducao de 92% do TOC inicial. Estes resultados evidenciam a eficiencia da integracao entre os processos foto-Fenton e lodo ativado no tratamento de efluentes contendo compostos recalcitrantes. / Phenol and phenolic compounds have been listed as priority-pollutants by the Environmental Protection Agency (EPA USA). They are often found in industrial effluents such as from pulp and paper, timber, plastics and synthetic polymer, pharmaceutical, pesticide, oil and petrochemical industries. Most of the traditional wastewater treatments have shown inefficiency against high phenol concentrations. This work aims to treat phenol solution via Advanced Oxidation Processes (AOP´s) to enhance medium biodegradability and using it as an effluent in a continuous activated sludge process. The purpose of the pre treatment is to modify the phenol structure leading it to its byproducts such as aromatics compounds and carboxylic acids. The experiments have shown the effectiveness of the pre-treatment by the biodegradability parameter BOD5/COD which was achieved 0,19 at 30 min of photo- Fenton reaction with a initial phenol concentration of 1000 mg.L-1 of TOC, 1 mmol.L-1 of FeSO4 and 100 mmol.L-1 of H2O2, added with a peristaltic pump along 2 hours of reaction. After the photochemical pre treatment, the same solution was used as a carbon source in a continuous activated sludge system for removing residual organic matter, with a reduction of 92% of the TOC initial. Those results have shown the efficiency when integrating photo-Fenton and activated sludge processes on the treatment of effluents containing recalcitrant organic compounds.
373

Emprego da flotação lamelar de alta taxa e convencional como pós-tratamento do efluente de sistema constituído de reator anaeróbio seguido de reator aeróbio tratando esgoto sanitário / Lamella design (high rate) and conventional flotation units applied to the post-treatment of the effluent from a system made up anaerobic reactor followed by aerobic reactor treating domestic sewage

Renata Cristina Moretti 20 May 2005 (has links)
O presente trabalho teve como objetivo o estudo da potencialidade de aplicação da flotação por ar dissolvido (FAD) lamelar (de alta taxa) e convencional como parte final de sistema de tratamento sequencial de esgoto sanitário, constituído de reatores anaeróbios de manta de lodo (UASB) seguidos de tanque de aeração. O trabalho, desenvolvido na Estação de Tratamento de Esgotos Jardim das Flores da cidade de Rio Claro, foi dividido em três etapas. Na primeira etapa, realizada com equipamento Flotateste, foram investigados os valores mais adequados de dosagens de polímero sintético catiônico, amido de araruta, cloreto férrico e associações entre cloreto férrico e polímero ou amido de araruta, de razão ar/sólidos (A/S), bem como de tempo e gradiente de mistura rápida e de floculação. Nessa etapa, os melhores desempenhos da FAD foram obtidos com o emprego de polímero catiônico, tanto isoladamente quanto associado ao cloreto férrico, sendo esta última condição imprescindível para maior remoção de fósforo. A flotação de liquor misto utilizando apenas o cloreto férrico como coagulante, apresentou desempenho extremamente insatisfatório, com a formação de flocos com características ruins de flotabilidade. Além disso, observou-se que a flotação desse tipo de efluente requisitou condições mais amenas de mistura, sendo que, em muitos casos, os melhores resultados foram obtidos mediante a eliminação da mistura rápida ou da floculação. Nas segunda e terceira etapas, realizadas com unidades piloto de flotação lamelar de alta taxa (FADAT) e convencional, respectivamente, e empregando apenas polímero como auxiliar de floculação/flotação (dosagem em torno de 1 g de polímero/kg de SST), foram investigados os valores mais adequados de Taxa de Aplicação Superficial (TAS), Taxa de Aplicação de Sólidos (TS) e quantidade de ar fornecida à flotação, calculada através da razão A/S ou da dosagem de ar (Dar), em g de ar/'M POT.3' de esgoto afluente, dependendo da concentração de sólidos suspensos totais afluentes à flotação (SSTafl). Através dos resultados dos ensaios pôde-se observar que a razão A/S é mais adequada para o cálculo da quantidade de ar na flotação de suspensões concentradas (SSTafl acima de 1100 mg/L no presente estudo), ao passo que Dar é mais representativo no caso da flotação de suspensões diluídas. Empregando a unidade FADAT, alimentada com liquor misto de tanque de aeração em boas condições de biofloculação, foi possível obter resultados satisfatórios para TAS de até 350 'M POT.3'/'M POT.2'.dia e TS entre 120 e 250 kg de SST/'M POT.2'.dia, desde que fornecida quantidade adequada de ar ao processo (Dar na faixa de 15,0 a 18,0 g de ar/'M POT.3' de afluente), para SSTafl entre 800 e 1100 mg/L. Na flotação lamelar de alta taxa, constatou-se que o bom desempenho esteve diretamente relacionado a baixos valores de SSTafl. As recomendações para a flotação com unidade de FAD convencional tiveram que ser mais conservadoras, devido às condições ruins de biofloculação apresentadas pelo liquor misto do tanque de aeração durante a realização da terceira etapa do trabalho. Nesses ensaios, os resultados mais satisfatórios foram obtidos com o emprego de TAS em torno de 200 'M POT.3'/'M POT.2'.dia, TS menor que 200 kg de SST/'M POT.2'.dia e A/S em torno de 0,020 (Dar de 21,0 g de ar/'M POT.3' de afluente), para SSTafl em torno de 1400 mg/L / The aim of this research was the study of the lamella design (high rate) and conventional dissolved air flotation (DAF) process potentiality of application as the final part of a domestic sewage sequential treatment system made up anaerobic reactors (UASB) followed by aeration tank. The work, developed at the Jardim das Flores WWTP of Rio Claro city, was separated in three phases. In the first phase, using the flotatest apparatus, the most suitable values of chemical (synthetic cationic polymer, arrow-root starch, ferric chloride and ferric chloride combined with polymer or arrow-root starch) dosages, air to solids ratio (A/S), as well as rapid mix and flocculation time and mean velocity gradient values, were investigated. In this phase, the best DAF performances were obtained with the application of cationic polymer, alone and associated to ferric chloride. The use of ferric chloride was essential to obtain better phosphorus removal results. The mixed liquor flotation using ferric chloride alone as primary coagulant presented extremely unsatisfactory performance, with the formation of flocks showing bad characteristics of flotability. Moreover, it was observed that flotation of this kind of effluent had requested gentler mixture conditions. In many cases, the best results were obtained by means of rapid mix or flocculation step elimination. In the second and third phases, using the lamella design and conventional flotation units respectively and cationic polymer as the only flocculation/flotation aid (dosage around 1 g of polymer/kg TSS), the most suitable values of Overflow Rate (OR), Solids Application Rate (SAR) and amount of air supplied to the flotation process, expressed as the A/S ratio or air dosage (AD, in g of air/'M POT.3' of influent) depending on influent total suspended solids concentration (TSSinfl), were investigated. The flotation essays results showed that the A/S ratio is more suitable for the air supply estimation in flotation of concentrated suspensions (TSSinfl above 1100 mg/L in this study). Contrarily, the parameter AD is more representative in cases of flotation of diluted suspensions. Using the lamella design unit, fed with aeration tank mixed liquor presenting good bio-flocculation conditions, it was possible to obtain adequate results applying OR as high as 350 'M POT.3'/('M POT.2'.day) combined with SAR values between 120 and 250 kg of TSS/('M POT.2'.day), since the adequate amount of air has been provided for the process (AD values between 15,0 and 18,0 g of air/'M POT.3' of influent), for TSSinfl between 800 and 1100 mg/L. For the lamella flotation, it was noticed that the best performance has been directly associated to lower values of TSSinfl. The recommendations for flotation using the conventional DAF unit had to be more conservative, taking into account the poor bio-flocculation conditions presented by the mixed liquor during the third phase of work. In theses essays, the more adequate results were obtained by applying OR around 200 'M POT.3'/('M POT.2'.day), SAR under 200 kg of TSS/('M POT.2'.day) and A/S ratio around 0,020 (AD of 21,0 g of air/'M POT.3' of influent), for TSSinfl around 1400 mg/L
374

Caracterização do cromo presente no lodo de galvanoplastia: avaliação técnica e econômica de processos de remoção / Characteristics of chromium from electroplating sludge: technical and economic evaluation of removal processes

ALVES, LUCAS C. 22 June 2016 (has links)
Submitted by Claudinei Pracidelli (cpracide@ipen.br) on 2016-06-22T12:30:02Z No. of bitstreams: 0 / Made available in DSpace on 2016-06-22T12:30:02Z (GMT). No. of bitstreams: 0 / O lodo gerado em processos de galvanoplastia é classificado pela ABNT NBR 10.004/04 como perigoso (classe I). Na literatura encontram-se poucos estudos referentes à recuperação do cromo presente no lodo gerado em sistemas de tratamento de efluentes de indústrias de galvanoplastia. Neste sentido, o presente estudo avaliou a remoção do cromo presente no lodo de galvanoplastia por meio de dois processos, visando avaliar à eficiência técnica e a viabilidade econômica de ambos. O Processo 1 consistiu na remoção do cálcio utilizando o ácido cítrico, seguida de lixiviação ácida. Na etapa de oxidação, variou-se a temperatura em 40ºC, 60ºC e 80ºC e no tempo de 30, 60 e 90 minutos, tendo em vista que a eficiência do processo de oxidação depende da temperatura e tempo. Nesta etapa do processo as concentrações de peroxido de hidrogênio (H2O2) utilizadas foram de 1,50, 3,00 e 4,50 mol.L-1. O Processo 2 realizou a oxidação do cromo sem efetuar as etapas de extração do cálcio e a lixiviação ácida. A oxidação do cromo ocorreu pelo mesmo método apresentado no Processo 1. A caracterização elementar da amostra determinou que o principal elemento constituinte do lodo é o cálcio (20,05% em massa), e que dentre os metais pesados destacam-se o cromo e o níquel (6,52% e 4,33% em massa, respectivamente). A maior eficiência de remoção do cálcio foi obtida na razão mássica de 8,00 (ácido cítrico/hidróxido de cálcio), com 51,76% em massa, seguida pela razão mássica de 5,50 com 36,75% em massa e 2,50 com 24,83% em massa. O melhor resultado de oxidação do cromo no Processo 1 foi obtido com tempo de 30 minutos, temperatura de 60ºC e concentração de peroxido de hidrogênio de 3,00 mol.L-1, com eficiência de 41,09% em massa. No Processo 2, obteve-se a remoção de 37,96% em massa de cromo a temperatura de 80ºC, por uma hora e 3,00 mol.L-1 de peróxido de hidrogênio. Avaliando os custos para remoção do cromo dos dois processos, determinou-se que o Processo 1 foi mais oneroso que o 2, porém ambos não apresentaram viabilidade econômica para aplicação em escala industrial. Nos dois processos efetuou-se a oxidação do cromo presente no lodo de galvanoplastia, permitindo a sua remoção parcial neste resíduo. Com isso obtiveram-se ganhos ambientais, pela diminuição deste elemento no resíduo de galvanoplastia, que na maioria das vezes é disposto em aterros classe I, gerando um passivo ambiental. / Dissertação (Mestrado em Tecnologia Nuclear) / IPEN/D / Instituto de Pesquisas Energeticas e Nucleares - IPEN-CNEN/SP
375

Microbiologia e cinética de sistema de lodos ativados como pós-tratamento de efluente de reator anaeróbio de leito expandido / Microbiology and kinetic of activated sludge system as post treatment of expanded bed anaerobic reactor

Luciana Coêlho Mendonça 22 November 2002 (has links)
Os principais objetivos deste trabalho foram analisar o desempenho de sistema combinado (escala piloto), constituído por reator anaeróbio de leito expandido (Ralex) seguido por sistema de lodos ativados, utilizado no tratamento de esgoto sanitário, correlacionar as características da microbiota do sistema de lodos ativados com os resultados físico-químicos e determinar a cinética de consumo de substrato no sistema de lodos ativados. O desempenho do sistema combinado quanto à remoção de DQO total e DQO filtrada foi de 82% e 80%, respectivamente. No sistema combinado, a remoção de nitrogênio total foi de 65% e a remoção de fósforo foi de 35%. A população de protozoários foi bem diversificada, sendo condizente com as características operacionais do sistema de lodos ativados. Arqueas metanogênicas foram capazes de sobreviver no tanque de aeração, porém em número reduzido. O modelo cinético que melhor representou a degradação de DQO filtrada, no sistema de lodos ativados, foi o de primeira ordem com residual. A constante aparente específica média foi de 0,05L/gSSV.dia. Nas condições estudadas, não ficou evidenciado o efeito da temperatura na cinética, provavelmente devido à resistência de transferência de massa. / The major objectives of this study were: (i) to evaluate the performance of a combined system (pilot scale) treating wastewater, composed by an expanded bed anaerobic reactor and an activated sludge system; (ii) to correlate microorganisms characteristics of the activated sludge system with the physical-chemical results; and (iii) to determinate the substrate consumption kinetics of the activated sludge system. The performance of the combined system in terms of total and filtrated COD was 82% and 80% respectively. Total nitrogen removal was 65% and total phosphorous removal was 35%, in the combined system. Protozoa populations were well diversified, according to operational characteristics of activated sludge. Methanogenics archeas survived into aeration tank, but in a reduced number. First order with residual kinetic model represented the filtered COD degradation, in the activated sludge system. The mean apparent specific constant was 0,05L/gVSS.day. In this study, the effect of temperature on kinetics was not evident, probably due to mass transfer resistance.
376

Definição do ciclo operacional de um reator seqüencial em batelada aeróbio (SBR) para tratamento de esgoto sanitário / Definition of the operational cycle of an aerobic sequencing batch reactor (SBR) for the treatment of sanitary sewage

Rodrigo Gibbin Marconi 19 January 2001 (has links)
No processo de lodos ativados por batelada, a definição de um ciclo operacional é de fundamental importância para o bom funcionamento de uma estação de tratamento de esgotos que utiliza esse tipo de tratamento. A adoção de um ciclo adequado pode trazer vários benefícios como o aumento da eficiência de tratamento, a introdução da remoção da matéria nitrogenada, por meio dos processos de nitrificação e desnitrificação do efluente e até diminuir o consumo de energia que é relativamente alto nesse tipo de tratamento. Foi aplicada então, a definição do ciclo operacional à ETE Bueno de Andrada que utiliza o processo de lodos ativados por batelada aeróbio para o tratamento da fase líquida. Foram experimentados alguns ciclos de operação com tempos e estratégias diferentes, variando-se os tempos de aeração, mistura, enchimento ou sedimentação. A aplicabilidade de cada estratégia de ciclo foi avaliada em termos da eficiência de remoção da matéria orgânica carbonácea, retratada com as análises de DBO e DQO do esgoto afluente e do efluente final. Foi desenvolvido também, o processo de automação da ETE Bueno de Andrada com o estudo e ajuste de um programa computacional que gera um arquivo de controle utilizado para controle do ciclo de operação dos SBRs. Os resultados mostraram que os ciclos operacionais entre 10 e 12h, consegue-se uma eficiência de remoção da matéria orgânica carbonácea entre 95 e 97%. / The definition of an adequate operational cycle for the batch activated sludge process is of fundamental importance for the proper operation of a sewage treatment plant. The use of a suitable cycle can bring many benefits namely the increase of the treatment efficiency, the introduction of the nitrogen organic material removal through the nitrification and denitrification process of the eflluent and the decrease of energy consumption that is relatively high in this process. The operational cycle definition is then applied to the Sewage Treatment Plant of Bueno de Andrada that use the aerobic batch activated sludge process for the liquid phase treatment. Some operational cycles are experimented with different times and strategies, changing the aeration, rnixture, filling or sedimentation times. The applicability of each cycle strategy was checked by the carbon organic material removal efficiency, measured through the BOD and COD analyses of the influent sewage and the treated eflluent. It was developed, too, the automation process of the Sewage Treatment Plant of Bueno de Andrada, cornplementing and adjusting the control computer program for the PLC that controls the SBRs operational cycle. The results showed that with operational cycles between 10 and 12 hours, the removal efficiency of the carbon organic material was between 95 and 97%.
377

Avaliação do tratamento combinado de lixiviado de aterro sanitário e esgoto sanitário em sistema de lodos ativados / Evaluation of the combined treatment of landfill leachate and domestic sewage in activated sludge system

Edilincon Martins de Albuquerque 05 June 2012 (has links)
Um dos principais resíduos gerados nos aterros é o lixiviado, que possui elevada concentração de matéria orgânica biodegradável e refratária e de matéria inorgânica, como nitrogênio amoniacal e metais pesados. O tratamento combinado de lixiviado com esgoto sanitário tem sido utilizado em algumas estações de tratamento de esgoto (ETE) brasileiras. No entanto, o processo ainda sofre vários questionamentos e incertezas, especialmente sobre os efeitos da adição do lixiviado sobre o sistema de tratamento. Nesse contexto, o presente trabalho visou avaliar a eficiência do tratamento combinado de lixiviado/esgoto em sistema de lodos ativados, em diferentes condições. Na primeira etapa desta pesquisa, foram realizados experimentos de tratabilidade em escala de bancada (regime de batelada) utilizando as proporções volumétricas de 0% (controle), 0,2%, 2% e 5% de lixiviado em diferentes condições experimentais. Dentre eles, o Experimento 2 (lixiviado pré-tratado por alcalinização e air stripping) se mostrou mais viável tecnicamente, alcançando eficiências de remoção da DBO, da DQO e do COD acima de 97, 82, 60%, respectivamente, até a proporção de 2% de lixiviado pré-tratado. Na segunda etapa da pesquisa, foi avaliada a tratabilidade utilizando reatores em escala piloto (regime contínuo) tratando esgoto sanitário com 2% (P1) e 0% (P2-controle) de lixiviado pré-tratado, com relação microrganismo-alimento de 0,22 kgDBO/kgSSV.dia, tempo de detenção hidráulica de 24 horas e idade do lodo de 20 dias. Os resultados indicaram viabilidade do tratamento nas condições estudadas com 2% de lixiviado pré-tratado, cujas eficiências médias de remoção da DBO, da DQO, do COD foram de 93, 84 e 60%, respectivamente. Esta pesquisa foi desenvolvida com apoio financeiro (Processo N° 2010/51955-2) da Fundação de Amparo à Pesquisa de São Paulo (FAPESP). / The leachate is one of the main wastes generated in landfills, it has a high concentration of biodegradable and refractory organic matter and inorganic matter, such as ammonia and heavy metals. The combined treatment of leachate with sewage has been used in various sewage treatment plants in Brazil. However, there are still many questions and uncertainties about the process, especially the effects of adding leachate on the treatment system. In this context, this study aimed at evaluating the efficiency of combined treatment of leachate/sewage in activated sludge under different conditions. In the first stage of this research, treatability experiments were carried out in a bench scale (SBR) using the volumetric proportions of 0% (control), 0.2%, 2% and 5% leachate under different experimental conditions. The Experiment 2 (leachate pretreated by alkalinization and air stripping) was more technically feasible, achieving efficiencies of removal of BOD, COD and DOC above 97, 82, 60%, respectively, until the proportion of 2% pre-treated leachate. In the second stage of the research was evaluated the treatability using pilot-scale reactors (continuous flow) for sewage treatment with 2% (P1) and 0% (P2-control) leachate pretreated. The operational parameters adopted were food-microorganism rate of 0.22 kgDBO/ kgSSV.d, hydraulic retention time of 24 hours and the sludge retention time of 20 days. The results indicated the viability of the combined treatment with 2% leached pretreated, whose average efficiency of removing BOD, COD, DOC were 93, 84 and 60% respectively. This research was developed with financial support (case No. 2010/2-51955) of Fundação de Amparo à Pesquisa de São Paulo (FAPESP).
378

Estudo da tratabilidade das soluções de lactose com ácidos húmicos e lactose com lixiviado de aterro sanitário por lodos ativados em escala de bancada

Rafaella Campos 20 March 2013 (has links)
O lixiviado de aterro sanitário é uma água residuária com elevada concentração de DQO, DBO, amônia, traços de metais pesados e substâncias orgânicas dificilmente biodegradáveis, tais como substâncias húmicas e celulósicas (lignina). Dada essas características, torna-se necessário que ele seja recolhido e devidamente tratado para evitar danos ao meio ambiente e à saúde humana. Uma prática que tem sido adotada por alguns municípios brasileiros é o direcionamento do lixiviado para tratamento consorciado em estações de tratamento de esgoto (ETE). No entanto, são poucos os estudos que avaliam a eficácia desse procedimento. Um dos questionamentos sobre o tratamento biológico diz respeito à remoção do material orgânico dificilmente biodegradável, representado principalmente pelas substâncias húmicas e, dentro dessa classe, destaca-se a fração de ácidos húmicos no lixiviado. Nesse contexto, o presente trabalho teve como objetivo verificar a tratabilidade das soluções contendo lactose, lactose com ácidos húmicos, lactose com 2% em volume de lixiviado de aterro sanitário bruto e lactose com 2% em volume de lixiviado pré-tratado por \"air stripping\", quando submetidas ao tratamento biológico em reatores de lodos ativados em escala de bancada. Assim, buscou-se verificar se essa tecnologia de tratamento é capaz de estabilizar, ainda que parcialmente, compostos orgânicos de difícil biodegradação presentes no lixiviado. A quantificação das substâncias de difícil biodegradação antes e após o tratamento foi realizada pelo método tentativo do \"Equivalente em Ácidos Húmicos\" que se encontra em fase de estudo. Os resultados demonstraram que houve uma remoção parcial dessas substâncias. As análises de espectroscopia na região do infravermelho indicaram que não ocorreu a adsorção dos ácidos húmicos no lodo, o que pode ser uma evidencia de que a redução da concentração dessas substâncias é de fato devida ao seu consumo e não pela precipitação no lodo. Além disso, a adição de 2% em volume do lixiviado não ocasionou redução da população de microrganismos no sistema. / Leachate from sanitary landfills is a type of effluent with high concentrations of COD, BOD, ammonia, heavy metal traces and hardly biodegradable organic compounds such as humic and cellulosic substances (lignin). Thus this effluent needs to be collected and treated in order to prevent damages to the environment and to human health. A common practice in Brazilian cities is to destine the leachate to a sewage treatment plant (STP). However, there are few studies that assess the efficiency of this procedure. One of the questions regarding the biological treatment concerns its efficiency in removing hardly biodegradable organic compounds, represented in the most part by the humic substances, given the high levels of humic acid in the leachate. Within this context, the present study had the objective to verify the treatability of solutions containing lactose, lactose with humic acids, lactose with 2% (in volume) of untreated sanitary landfill leachate, and lactose with 2% of leachate pre-treated by air stripping, submitted to biological treatment in laboratory-scale activated sludge reactors. Thus this paper assessed if such treatment technology can stabilize, even if only partially, the hardly biodegradable organic compounds found in leachate. The quantification of these substances prior to and after treatment was made by using a tentative method called Humic Acids Equivalent, which is still in the phase of studies. The results show that there was a partial removal of these substances. The spectroscopy analyses on the infrared region indicated that there was no adsorption of humic acids onto the sludge, which evidences that the decrease in the levels of these substances was due to their consumption and not precipitation onto the sludge. Also, the addition of 2% of leachate did not reduce the population of microorganisms in the system.
379

Pós-tratamento por lodos ativados de efluente de um reator anaeróbio compartimentado no tratamento de esgoto sanitário / Post-treatment by activated sludge of anaerobic baffled reactor effluent in the treatment of sanitary sewage

Fábio José Coletti 15 December 1997 (has links)
Estudou-se nesta pesquisa o processo de lodos ativados para pós-tratamento do efluente proveniente de um reator anaeróbio compartimentado, que recebe esgoto sanitário. Isso se deu em vários ensaios em sistema descontínuo (\"batch\'\') para avaliar a biodegradabilidade dessa água residuária e em um ensaio em sistema contínuo com finalidade de melhorar a qualidade do efluente final e determinar os coeficientes cinéticos, os parâmetros a\' e b \', a taxa de utilização de oxigênio e o coeficiente &#945. Também realizaram-se ensaios hidrodinâmicos para verificação do tipo de reator utilizado. A pesquisa desenvolveu-se com base em uma célula de aeração, em escala de laboratório, composta por quatro câmaras (reatores) que possuíam tanque de aeração e decantador secundário justapostos, separados por uma cortina fixa. Não houve controle de temperatura nos dois sistemas utilizados. No ensaio em sistema contínuo quatro reatores foram operados simultaneamente com as respectivas idades do lodo de 5, 10, 15 e 20 dias durante 35 dias. O tempo de detenção hidráulico foi mantido próximo de 8 horas. Nesse ensaio os reatores quando se encontravam estabilizados dinamicamente, apresentaram remoção superior a 95% para DBO bruta, 90% para DBO filtrada, 87% para DQO bruta, 80% para DQO filtrada e 95% para SST. Mesmo não sendo realizado processo adicional para remoção de nutrientes, os reatores, após a estabilização dinâmica, apresentaram remoção de fosfato de até 28% e de nitrogênio amoniacal até níveis de não serem detectados pelos métodos de análises utilizados. Os ensaios hidrodinâmicos mostraram que os reatores são do tipo mistura completa. / In this work the activated sludge process for post-treatment of effluent anaerobic baffled reactor which receives sanitary sewage was studied. This was established during various experiments in batch system to evaluate the biodegradable of this wastewater and also in an experiment of continuous system aiming to improve the quality of the final effluent and to determine the kinetic coefficients, the a\' and b\' parameters, the oxygen uptake rate and the &#945 coefficient. Hydrodynamic tests to verify the type of reactor used in this research were also perfonned. The work was developed and based on an aeration cell bench-scale, composed of four chambers (reactors) which had an aeration tank and a secondary settling tank in the same chamber, separated by a fixed baffle. Temperature control was not used in both systems. In the experiment of continuous system, four reactors were simultaneously operated with sludge age of 5, 10, 15 and 20 days during 35 days. The hidraulic retention time was maintained at around 8 hours. When the reactors were dynamically stabilized, they showed an average removal superior to 95% for BOD (biochemical oxygen demand), 90% for filtrated BOD, 87% for COD (chemical oxygen demand), 80% for filtrated COD and 95% for TSS (total suspended solids). Without additional process of nutrient removal, after the dynamic stabilization the reactors presented up to 28% of total phosphate removal and ammonia nitrogen up to levels of not being detected by the analyses methods used. The hydrodynamic tests showed that the reactors are of the complete-mix type.
380

Design and performance evaluation of an anaerobic sludge blanket reactor with mechanical mixing system and a high-rate settler treating domestic wastewater / Concepção e avaliação do desempenho de um reator anaeróbio de manta de lodo dotado de agitador mecânico e decantador de alta taxa tratando esgoto sanitário

Bruno Pessotto 24 April 2015 (has links)
The UASB (Upflow Anaerobic Sludge Blanket) reactor, developed by Prof. Gatze Lettinga and his colleagues in the Netherlands more than thirty years ago, is successfully employed in many sewage treatment plants in countries with tropical and subtropical climate. However, are still reported serious operational issues related to the three-phase separators and problematic aspects involving the complexity of its influent distribution system. The focus of this research was to simplify the introduction and dispersion of the sewage in the reactor as well as enhancing the sludge retention, by replacing the characteristic piping system for a mechanical mixing apparatus and substituting the (conventional) three-phase separators by a high-rate settler, respectively. In essence, it was proposed a system partitioned into two distinct regions: one for reaction (i.e. anaerobic digestion of organic matter), in which the sludge blanket was mechanically mixed through the action of a rotating impeller, and another for the removal of suspended solids by the use of a lamella plate clarifier; a sludge recirculation system was also implanted, to pump the settled biomass back to the digestion compartment. The research was subdivided into three main phases: in the first two phases, bench-scale experiments were performed in order to obtain basic data for the design of the mechanical mixing and sedimentation devices, while the third phase consisted of the application of these technologies in a pilot-scale system with total volume of 20.8 m3 (comprised of a 17.0 m3 digestion chamber and a 3.8 m3 compartment for solids removal), as well as its performance assessment. During the development of the research, domestic sewage was applied to feed the experimental system, which was located at the School of Engineering of São Carlos (Campus I) in São Carlos (São Paulo State, Brazil). Throughout the period of effective operation, which lasted 130 days, four distinct operating modes were tested (characterized by intermittent mixing and varying hydraulic loading rates, ranging between 27.6 and 66.5 m3.d-1) and the system reached maximum removal efficiencies of BOD, COD and TSS at rates of 82%, 72% and 83%, respectively. The high-rate settler presented an impressive efficiency removing suspended solids (rates up to 98%). The research showed that the new \"Anaerobic Activated Sludge Blanket\" system (A2SB) can provide satisfactory performance even operating without the three-phase separator and influent distribution system. / O reator UASB, desenvolvido pelo Prof. Gatze Lettinga e colaboradores na Holanda há mais de trinta anos, é utilizado com sucesso em muitas estações de tratamento de esgoto sanitário em países de clima tropical e subtropical. Entretanto, ainda são relatadas sérias questões operacionais relacionadas aos separadores trifásicos e aspectos problemáticos envolvendo a complexidade de seu sistema de distribuição do esgoto afluente. O foco da presente pesquisa foi o de simplificar a distribuição e dispersão do esgoto no reator, assim como aprimorar a retenção de lodo, mediante substituição do sistema convencional de tubos por misturador mecânico e do (tradicional) separador trifásico por decantador de alta taxa, respectivamente. Em essência, propôs-se reator dividido em duas regiões distintas: uma para reação (i.e. digestão anaeróbia da matéria orgânica), na qual a manta de lodo foi agitada mecanicamente através do movimento rotacional de um impelidor, e outra, para remoção de sólidos suspensos mediante uso de decantador com placas paralelas; um sistema de recirculação do lodo também foi implantado, para bombear a biomassa sedimentada até o compartimento de digestão. A pesquisa foi subdividida em três fases: nas duas primeiras, experimentos em escala de bancada foram realizados visando obtenção de dados básicos para dimensionamento dos sistemas de agitação e de decantação, enquanto que a terceira fase consistiu na aplicação dessas tecnologias em sistema de tratamento, em escala piloto, com volume útil total de 20,8 m3 (composto por uma câmara de digestão de 17,0 m3 e um compartimento de 3,8 m3 para remoção de sólidos), assim como na análise de seu desempenho. Durante a pesquisa, esgoto sanitário foi utilizado para alimentar o sistema experimental, instalado na Escola de Engenharia de São Carlos. Ao longo do período de operação, que durou 130 dias, quatro condições operacionais foram testadas (caracterizadas pela agitação intermitente e diferentes taxas de carregamento hidráulico, que variaram entre 27,6 e 66,5 m3.d-1) e o sistema alcançou eficiências de remoção máxima para DBO, DQO e SST de 82%, 72% e 83%, respectivamente. O decantador de alta taxa apresentou surpreendente eficiência de remoção de sólidos suspensos (taxas de até 98%). A pesquisa demonstrou que o novo sistema A2SB (Anaerobic Activated Sludge Blanket) pode apresentar desempenhos satisfatórios, mesmo operando sem separador trifásico e sistema de distribuição do esgoto afluente.

Page generated in 0.0368 seconds