• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 1964
  • 1900
  • 365
  • 227
  • 184
  • 146
  • 83
  • 54
  • 53
  • 48
  • 46
  • 38
  • 26
  • 24
  • 24
  • Tagged with
  • 6192
  • 1010
  • 778
  • 721
  • 628
  • 626
  • 615
  • 587
  • 536
  • 506
  • 461
  • 453
  • 399
  • 382
  • 374
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
831

Contribuição do glutaraldeído como componente de sistemas adesivos dentinários / Influence of glutaraldehyde priming on bond strengths of an experimental adhesive system applied to wet and dry dentin

Cilli, Renato 10 August 2007 (has links)
Neste trabalho foram testadas as seguintes hipóteses nulas: 1) Não há diferença entre os valores de resistência de união entre resina restauradora e dentina quando uma solução aquosa de glutaraldeído é aplicada como primer dentinário antes do emprego do agente adesivo; 2) Não há diferença entre os valores de resistência de união, quando a aplicação do mesmo sistema adesivo se dá em condições de dentina úmida ou seca. Dentes humanos foram selecionados, e tiveram sua porção oclusal desgastada, expondo a parte média da dentina coronária para adesão. Quatro grupos foram formados, variando-se a aplicação ou não do primer de glutaraldeído e a condição de umidade dentinária: úmida ou seca. Após aplicação e fotopolimerização do sistema adesivo experimental, foram confeccionados blocos resina composta de 4mm de altura sobre a superfície oclusal e os dentes foram preparados para o teste de microtração para a avaliação da resistência de união. Os resultados obtidos foram submetidos à análise de variância a um critério e teste de Tukey (\'alfa\'\'=0,05). A aplicação do primer de glutaraldeído aumentou significativamente os resultados de resistência de união. Não houve diferença estatística entre o mesmo sistema experimental se aplicado em dentina seca ou úmida. A hipótese 1 não se confirma e aceita-se a hipótese 2. / This work tested the following null hypothesis: 1) There is no difference between resin-dentin bond strengths when a glutaraldehyde primer solution is applied onto demineralized dentin during adhesive bonding. 2) There is no difference between resin-dentin bond strengths when the same experimental adhesives systems are applied whether in dry or wet demineralized dentin conditions. Human, extracted upper third molars were selected. The oclusal surfaces were ground flat, and midcoronal dentin was exposed for bonding. Four groups of six teeth were formed. Two groups were designated for dry dentin technique and two for the wet one. After application and photopolymerization of the bonding system, a 4 mm-high resin core build-up was fabricated over the adhesive layer. Specimens were then prepared for microtensile bond test for bond strengths evaluation. The obtained data were submitted to ANOVA and Tukey test (\'alpha\'=0.05). Glutaraldehyde primer application significantly improved resin-dentin bond strength. No significant difference was observed when the same experimental adhesive system was applied whether in dry or wet dentin conditions. Such results require to reject the first null hypothesis and accept the second one.
832

Macroarchitecture et résistance osseuse : rôle de l'os cortical / Macroarchitecture and bone strength : role of the cortical bone

Briot, Karine 04 December 2009 (has links)
L’objectif de ce travail était d’étudier certains aspects de la géométrie ou macroarchitecture afin de mieux comprendre la contribution de la géométrie sur le risque de fracture. Pour les os tubulaires, l’apposition périostée tente de compenser la perte osseuse après la ménopause et il existe peu d’études pour les vertèbres. Dans une étude prospective, les dimensions des corps vertébraux augmentent significativement à 3 ans chez les femmes ménopausées ostéoporotiques et que cette augmentation est fortement associée à la taille initiale des os suggérant que les os plus grands ont besoin d’une expansion périostée plus importante pour maintenir la résistance osseuse. Des études antérieures ont suggéré qu’il fallait évaluer la géométrie du rachis dans sa globalité en étudiant le rôle des courbures rachidiennes. Dans une deuxième étude prospective de 3 ans chez des femmes ménopausées ostéoporotiques, la cyphose thoracique est un facteur de risque de fractures vertébrales même après ajustement sur la présence de fractures vertébrales prévalentes. Une troisième étude prospective qui a cherché à identifier les paramètres géométriques associés au risque de fracture de hanche chez les femmes ménopausées ostéoporotiques non traitées montre que l’épaisseur corticale fémorale mesurée par l’outil HSA (Hip Structural Analysis) améliore la prédiction du risque de fracture de hanche indépendamment de la mesure de la densité minérale osseuse (DMO). L’outil géométrique que nous avons développé pour s’affranchir de l’influence de la DMO montre que l’augmentation de la distance intertrochantérienne est associée à une augmentation du risque de fracture indépendamment de la DMO. En revanche l’outil actuel est peu reproductible pour la mesure de la corticale fémorale. / The aim of the study was to study certain aspects of bone geometry or macroarchitecture to understand better the contribution of bone geometry on the risk of fracture. For tubular bones, periosteal apposition can occur to compensate bone loss after the menopause and there is no data concerning the prospective changes in vertebral body dimensions. In a prospective study of women with postmenopausal osteoporosis, vertebral body dimensions increase over 3 years in women and the bigger bones need more periosteal expansion to maintain bone strength. Previous studies showed that whole spine geometry and especially the spinal curvatures need be evaluated to understand the role of vertebral geometry on the risk of fracture. In a second prospective study in postmenopausal osteoporotic women, thoracic kyphosis is a risk factor for vertebral fractures over 3 years, even after adjusting on presence of prevalent fractures. A third prospective study aimed at identifying the geometric parameters associated with an increase risk of hip fracture in postmenopausal osteoporotic women untreated. Femoral cortical thickness measured by HSA tool (Hip Structural Analysis) is associated with an increase risk of hip fracture, independently of bone mineral density (BMD). The geometrical tool which we developed to eliminate the influence of the BMD shows that increase in the intertrochanteric distance is associated with an increase risk of hip fracture.
833

Degradação quimica da união de materiais adesivos ao substrato dentinario : analise mecanica e micromorfologica / Chemical degradation of adhesive materials bonded to dentin substrate : mechanical and micromorphologic analysis

Correr, Ana Rosa Costa, 1977- 05 October 2018 (has links)
Orientador: Regina Maria Puppin-Rontani / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-10-05T18:32:34Z (GMT). No. of bitstreams: 1 Costa_AnaRosa_M.pdf: 3213917 bytes, checksum: 992b632a45094f40763749a7a2048776 (MD5) Previous issue date: 2009 / Resumo: O propósito neste estudo foi avaliar o efeito da ciclagem dinâmica de pH (solução DES/RE) e o tempo de armazenagem na degradação da união resina/dentina, por meio do ensaio de resistência da união à microtração e quantificar os íons flúor liberados do sistema adesivo. A superfície da face oclusal de terceiros molares humanos extraídos foi desgastada com lixa de carbeto de silício de granulação 600. Em seguida, os dentes foram separados em 2 grupos de acordo com o sistema adesivo utilizado (n=4): Clearfil Protect Bond (PB) (Kuraray) e Clearfil SE Bond (SE) (Kuraray). Um bloco de resina composta TPH (Dentsply) de aproximadamente 6 mm de espessura foi unido ao dente com os sistemas adesivos, preparados de acordo com as recomendações do fabricante e cada camada de 2 mm de espessura foi irradiada por 40 segundos. Após 24 horas em umidade relativa à 37º C, as amostras foram seccionadas perpendicularmente à área de união, para obter palitos com área de secção transversal de 1mm2 e separados em 6 grupos de acordo com o período de armazenagem: G1 - PBI (imediato - controle); G2 - PBC (ciclagem dinâmica de pH); G3 - PBA (armazenagem em água deionizada por 140 dias); G4 - SEI (imediato - controle); G5 - SEC (ciclagem dinâmica de pH); e, G6 - SEA (armazenagem em água deionizada por 140 dias). Em seguida, os palitos foram submetidos ao ensaio de resistência de união à microtração em máquina de ensaio universal (Instron) a velocidade de 0,5 mm/minuto. Para análise da liberação de flúor, os palitos foram armazenados individualmente em 1 mL de solução DES (n=8), RE (n=8) ou água deionizada (n=23) para o sistema adesivo Clearfil Protect Bond com um eletrodo íon específico conectado a um potenciômetro, usando 0,05 mL do sistema tampão concentrado TISAB III adicionado a 0,5 mL da solução da amostra, por 1 a 4 (DES, RE e água deionizada) e 30 dias (água deionizada). Os dados foram submetidos à Análise de Variância, ao teste de Tukey (5%) e ao teste de Friedman's. Os valores de resistência de união à microtração (MPa) foram: 30,4±11,6 (PBI), 29,5±9,1 (PBC), 27,1±11,6 (PBA), 28,9±11,1 (SEI), 27,1±7,6 (SEC) e 21,3±10,9 (SEA). Nenhuma diferença estatística foi observada entre os dois sistemas adesivos em todas as condições de tratamento (p>0,05). O PBI e o SEI apresentaram valores de resistência de união à microtração significativamente maiores em relação ao PBA e ao SEA (p<0,05). A ciclagem dinâmica de pH no PB e SE não mostrou diferença significativa nos valores de resistência de união à microtração, quando comparado com o imediato e a armazenagem em água deionizada por 140 dias (p>0,05). A concentração de flúor presente nas soluções DES/RE foi menor que 0,03125 ppm e nenhuma quantidade esteve presente na água, para o sistema adesivo testado (Clearfil Protect Bond). Conclui-se, portanto, que nenhuma diferença significativa foi observada entre os sistemas adesivos. A armazenagem em água deionizada por 140 dias diminuiu os valores de resistência da união à microtração, para os dois sistemas adesivos. / Abstract: The purpose of this study was to evaluate the effect of the dynamic chemical challenge pH (DES/RE solutions) and storage regimen on degradation of resin/dentin-bonding using the microtensile bond strength (µTBS) and quantify fluoride release from the adhesive system. Superficial occlusal dentin of extracted human molars was exposed and wet ground with 600-grit SiC paper. Then, teeth were randomly distributed into 2 groups according to adhesive systems (n=4): Clearfil Protect Bond (PB) (Kuraray) and Clearfil SE Bond (SE) (Kuraray). A block of composite resin TPH (Dentsply) with 6 mm thickness was bonded to the tooth with the adhesive systems according to manufacturer's instructions and each thickness with 2 mm was light cured for 40 seconds. After 24 hours in moist environment at 37oC, the specimens were sectioned perpendicular to the bonding area to obtain 1mm2 sectional area sticks, which were randomly divided into 6 groups according to storage regimen: G1 - PBI (immediate-control); G2 - PBC (pH cycling model); G3 - PBW (140 days water storage); G4 - SEI (immediate - control); G5 - SEC (pH cycling model); and, G6 - SEW (140 days water storage). After that, the sticks were submitted to microtensile bond strength (µTBS) test in a Universal machine (Instron) at a crosshead speed of 0.5mm/min. Fluoride concentration in demineralization (n=8) / remineralization (n=8) solutions and deionized water (n=23) was obtained by collecting 0,5 mL of these solutions and 0,05 mL of TISAB III, from 1 to 4 days ( De, Re and deionized water) and 30 days (deionized water). Fluoride release was detected using a fluoride-specific electrode connected to a microprocessor ion analyzer.The data were submitted to ANOVA and Tukey's tests (p<0.05) and Friedman's tests. Microtensile bond strength- µTBS (MPa) mean values were 30.4±11.6 (PBI), 29.5±9.1 (PBC), 27.1±11.6 (PBW), 28.9±11.1 (SEI), 27.1±7.6 (SEC) and 21.3±10.9 (SEW). There was no significantly statistical difference between PB and SE in all conditions of treatment (p>0.05). The PBI and SEI showed significantly higher µTBS values compared to PBW and SEW (p<0.05). The pH cycling model in the PB and SE didn't show significantly difference on µTBS values when compared immediate and the deionized water storage for 140 days (p>0.05). Fluoride concentrations present in the DES/RE were less than 0.03125 ppm and no in deionized water, regardless of the adhesive system tested. No significantly difference was found between adhesive systems in all conditions. The 140-day water storage decreased the µTBS values from two adhesives systems. / Mestrado / Materiais Dentarios / Mestre em Materiais Dentários
834

Concreto de alta resistência: composição, propriedades e dimensionamento / High-strength concrete: composition, properties and design

Silva, Inês Santana da 03 February 1995 (has links)
Concretos de alta resistência têm sido usados em estruturas, atualmente, em diversas partes do mundo. Entretanto, no Brasil, pouco se conhece sobre seu comportamento. Este trabalho fornece uma visão geral das aplicações, dos materiais empregados na produção, das propriedades mecânicas e do comportamento estrutural dos concretos de alta resistência. Resultados experimentais obtidos por alguns pesquisadores, para pilares com carga axial e para vigas sujeitas a flexão e a cisalhamento, são comparados com valores teóricos, calculados com procedimentos usuais relativos a concretos de resistência usual. Para os pilares, é inquestionável a necessidade do confinamento do núcleo de concreto, utilizando armadura de cintamento. Na flexão das vigas, as taxas mínimas para armadura longitudinal, sugeridas pelas normas para concretos usuais, não são suficientes; é importante ter valores maiores que esses. E para cisalhamento, as recomendações das normas são satisfatórias. / Nowadays, high-strength concrete has been used in structures all over the world. However, in Brazil, not much is known about its behavior. This work provides an overview of the applications, the materials employed in production, the mechanical properties, and the structural behavior of high-strength concrete. Experimental results obtained by several researchers, for columns under axial load and beams under flexure and shear, are confronted with theoretical values, computed by normal procedures relative to normal strength concrete. For columns, it is unquestionable the need of confinement of the concrete core by transverse reinforcement. In beams under flexure, the minimum rates for longitudinal reinforcement, suggested by the codes for usual concrete, are not enough; it is important to have values greater than those. And for shear, the codes requirements are satisfactories.
835

Relação entre a força propulsora e a velocidade nos quatro estilos competitivos da natação / Relationship between the propulsive force and speed in the four competitive strokes in swimming

Santos Junior, Joel Moraes 29 January 2013 (has links)
Embora muitos estudos tenham investigado a contribuição da força propulsora na velocidade de nadadores, a maioria das pesquisas se restringiu ao estilo crawl e no nado como um todo. Sendo assim, o objetivo do presente estudo foi mensurar e comparar a força propulsora e o desempenho de velocidade nos quatro estilos competitivos e verificar a relação entre elas durante o nado completo, o nado somente de pernas e o nado somente de braços em nadadores competitivos. Participaram do estudo 37 nadadores do sexo masculino com experiência competitiva de no mínimo dois anos, com idade entre 15 e 19 anos. A amostra foi dividida pelos estilos borboleta (n=9), costas (n=7), peito (n=9) e crawl (n=12). Foram medida as variáveis de força propulsora (VFP) no nado atado (NA) nas seguintes situações; força propulsora máxima de nado em 10 segundos (FPM10), força propulsora máxima de pernas em 10 segundos (FPMp), força propulsora máxima de braços em 10 segundos (FPMb), força propulsora máxima de nado em 25 segundos (FPM25) força propulsora média de nado em 25 segundos (FPm25). Também foi mensurada a velocidade nas metragens de 15 e 50 metros (V15 e V50). Cada nadador realizou os testes de força e velocidade nos principais estilos de competição. Os resultados demonstraram correlações entre as VFP com a velocidade para os quatro estilos competitivos no nado completo (entre r=0,62 e 0,97), na força propulsora de pernas nos estilos costas e crawl (r=, 0,77, 0,73 e 0,72) e para a força propulsora de braços no estilo crawl (r=0,73). O estilo peito se correlacionou de maneira moderada negativamente (r=, -0,69, -0,75, -0,76 e -0,77) com a FPM10, FPM25, FPM25 e FPm25. Conclui-se que a força propulsiva apresentou relação com a velocidade nos quatro estilos competitivos e que tal relação é melhor no nado completo quando comparada aos membros inferiores e superiores / Although many studies have investigated the contribution of propulsive force in speed of swimmers, most studies has been restricted to crawl and complete swimming. So, the objective of this study was to measure and compare the propulsive force and speed performance on all four competitive strokes and the relation between them during complete swimming, propulsive force of the legs and of the arms. The study included 37 male swimmers competitive with at least two years, with ages between 15 and 19 years old. The sample was divided by styles butterfly (n = 9), back (n = 7), breast (n = 9) and crawl (n = 12). We analyze the propulsive force variables (VFP) in tethered swimming (NA) in situations: maximum propulsive force of swimming in 10 seconds (FPM10) maximum propulsive force of legs in 10 seconds (FPMp), maximum propulsive force of arms in 10 seconds (FPMb), maximum propulsive force of swimming in 25 seconds (FPM25) mean propulsive force of swimming in 25 seconds (FPm25). Also the speed was measured at distances of 15 and 50 meters (V15 and V50). Each swimmer performed the tests of strength and speed in the main styles of competition. The results showed correlations between VFP with speed for the four competitive swimming in complete swimming (between r = 0.62 and 0.97), in the propulsive force of legs in the back and crawl styles (r = 0.77, 0.73 and 0.72) and the propulsive force of arms in the crawl (r = 0.73). The breaststroke showed moderate negative correlation (r = -0.69, -0.75, -0.76 and -0.77) with FPM10, FPM25, and FPM25 FPm25. It is concluded that the propulsive force was related to the speed in four competitive and that this relationship is better in comparison to the complete swimming upper and lower limbs
836

Estudo do efeito springback em aços avançados de alta resistência aplicados a indústria automobilística /

Silva, Erika Aparecida da. January 2012 (has links)
Orientador: Marcelo dos Santos Pereira / Banca: Marcelino Pereira Nascimento / Banca: Rosinei Batista Ribeiro / Resumo: Este projeto é um estudo do efeito springback em quatro tipos de aços de alta resistência, sendo estes bifásico, baixo carbono, endurecível após pintura e com interstícios livres, aplicados atualmente como matéria-prima na produção de veículos. Neste contexto está inserido o desenvolvimento de novos aços avançados de alta resistência em consonância com o projeto ULSAB-AVC, que visa à produção de veículos seguros e econômicos para o século 21. A caracterização mecânica do efeito springback foi realizada por intermédio de ensaio de conformação mecânica, denominado dobramento de três pontos ao ar, como uma adaptação ao ensaio de flexão cilíndrica livre. Foram avaliadas também as propriedades mecânicas do material definidas pelo ensaio de tração, objetivando a determinação da resistência à tração, do limite de escoamento e do alongamento. Além disso, foi avaliada a caracterização microestrutural dos aços avançados, identificando e quantificando-se as fases presentes em coexistência por meio do processamento digital de imagens. Os resultados mostram que o efeito springback no aço bifásico, devido à sua alta resistência mecânica, apresenta as maiores taxas de springback e causa uma diminuição na "razão de aspecto" dos grãos que sofreram conformação mecânica e tentaram retornar às suas formas originais. Aços de baixo carbono e endurecíveis após a pintura, não sofrem efeito springback suficiente para causar alteração na forma dos grãos, sendo que a variação da "razão de aspecto" depende da combinação do alongamento e resistência mecânica destes aços. Já o aço com interstícios livres, devido a sua menor resistência mecânica, o efeito springback apresenta as menores taxas e a variação da razão de aspecto depende somente da capacidade de alongamento desse aço / Abstract: This is a study of the springback effect on four kinds of high strength steel, wich are dual-phase, low carbon, bake hardening and interstitial free, currently used as feedstock in the production of vehicles. In this context is inserted the development of new advanced high steel resistance in accordance with the project ULSAB-AVC, which aims to produce safe and economical vehicle for the 21st century. The mechanical characterization of the springback effect was performed by means of a test of mechanical conformation, called three-point air bending, done by adapting to unconstrained cylindrical bending test. Were also evaluated the mechanical properties of material defined by the tensile test, in order to determine the tensile strength, yield strength and the elongation. Furthermore, was performed the microstructural characterization of advanced steels by identificating and quantificating of present phases in coexistence by means digital image processing. The results indicates that the springback effect in dual-phase steel, due to its high mechanical strength, has the highest springback rates and causes a decrease in the "aspect ratio" of the grains that suffered mechanical conformation attempting to return to its original forms. Low carbon and bake hardening steels, have not enough springback effect to cause change in the shape of the grains and the change of the "ratio aspect" depends on the combination of both elongation and mechanical strength of these steels. Yet on the interstitial free steel, due to its lower mechanical strength, the springback effect has the lowest rates and the change in "aspect ratio" depends only on elongation capacity of the steel / Mestre
837

Estimadores da resistência mecânica característica da madeira /

Pinheiro, Wendell, 1976- January 2011 (has links)
Orientador: Adriano Wagner Ballarin / Banca: José Raimundo de Souza Passos / Banca: Luiz Antonio Targa / Resumo: A qualificação da madeira para uso estrutural é feita com base na sua resistência característica à compressão paralela às fibras. A partir de valores individuais de resistência à compressão paralela de corpos de prova de uma amostra representativa do lote de madeira, a resistência característica é avaliada com estimador específico, proposto pela NBR 7190 (ABNT, 1997). Com o valor da resistência característica, o lote de madeira é classificado em classes de resistência (três classes distintas para madeiras de coníferas e quatro classes distintas para madeira de folhosas) que variam de 20 MPa a 60 MPa. Lotes de madeira com maior valor de resistência característica levam, na maioria das vezes, à otimização dos projetos estruturais. O objetivo principal deste trabalho foi avaliar a eficiência de vários estimadores da resistência característica de lotes de madeira de distintas procedências, gêneses e idades das árvores, com base em suas aplicações em amostras de diferentes tamanhos amostrais. Para o estudo foram utilizados lotes de resultados de resistência mecânica da madeira de diversos conjuntos de dados, abrangendo resistências à compressão paralela às fibras e resistências ao cisalhamento de madeiras nativas e de reflorestamento, coníferas e folhosas. Com uso do software estatístico SAS, para cada lote sortearam-se repetidamente amostras, variando-se os tamanhos amostrais e, a partir dos valores de resistência dos indivíduos de cada amostra foram calculadas as resistências características dos lotes. Tomando-se a resistência característica do lote (aqui assumido como população) como referencial, foi avaliada comparativamente a eficiência de cada estimador, com base no erro quadrático médio e no desvio da estimativa. 2 Os resultados mostraram que o estimador... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: In Brazil, lumber classification for structural purposes is based on its characteristic strength in compression parallel to grain. From individual values of strength in compression parallel obtained from specimens of a sample, characteristic strength is evaluated with a particular estimator proposed by the standard NBR 7190 - Design of wood structures (ABNT, 1997) for general usage (all the mechanical properties). With this characteristic strength, lumber lot is classified into classes of strength (three different classes of coniferous woods and four different classes for hardwood) ranging from 20 MPa to 60 MPa. Lumber lots with higher characteristic strength leads, in general, to a design optimization. The main objective of this study was to evaluate the efficiency of several estimators of characteristic strength of lumber lots with distinct origin, genesis and ages, based on their application in samples with different size. Lots of results of strength in compression and in shear parallel to grain of conifers and hardwood from native and reforested plantation were used. Using SAS - Statistical Analysis System - specimens were randomly sampled from each lot - varying sample size from 6 to 42 specimens - from which the characteristic strength of the lot was calculated each time based on the estimators. Taking as referential the characteristic strength of the full lot (assumed as the population), comparative efficiency of the estimators were analyzed based on MSE (mean squared error) and deviation of the estimation. Results showed that the estimator proposed by NBR 7190(ABNT, 1997) was not the more efficient in all cases. For compression and shear parallel to grain, best estimations of characteristic strength were obtained with the estimator that uses lots central tendency and dispersion parameters in its formulation... (Complete abstract click electronic access below) / Mestre
838

\"Influência da fluorose dental na resistência de união de sistemas adesivos ao esmalte: análise em microscopia eletrônica de varredura e teste de microtração\" / Influence of dental fluorosis on the bond strength of adhesive system to enamel

Luciana Faria Sanglard Peixoto 11 December 2006 (has links)
Objetivou-se observar a influência da fluorose dental nas características do padrão de condicionamento ácido e na penetração de sistemas adesivos no esmalte, por microscopia eletrônica de varredura (MEV) e na resistência de união de sistemas adesivos ao esmalte, por teste de microtração. Para tal, 196 dentes permanentes posteriores foram classificados seguindo o Índice Thylstrup e Fejerskov (TF= 0, 1 e 4), sendo selecionados 69 deles. Adesivos de 2 passos, um autocondicionante, Clearfil SE Bond®, e um de condicionamento ácido total, Adper Single Bond 2® foram usados. Para análise em MEV do padrão de condicionamento e das réplicas de resina, 27 pré-molares foram seccionados no sentido mesiodistal e divididos em 9 grupos (n=3). As superfícies vestibulares foram selecionadas e seccionadas no sentido longitudinal, sendo metade para cada análise. Os espécimes pertencentes ao grupo do ácido fosfórico foram condicionados com tempos de 15 ou 60 segundos, lavados com ar/água por 20 segundos e secos. Os espécimes do grupo Clearfil SE Bond® receberam aplicação do primer do material, e em seguida, tratamento para removê-lo. Para obter as réplicas de resina, as superfícies foram delimitadas (2x2mm) com fita isolante, tratadas com cada adesivo, e submetidas à construção de bloco de resina (Filtek Z250TM ? 3M do Brasil) com 2 mm de altura. Esses espécimes foram imersos em HCl a 18% por 48h e lavados com água destilada em ultra-som por 15 minutos. O teste de microtração foi realizado na superfície vestibular intacta de 42 terceiros molares divididos em 7 grupos e subdivididos de acordo com grau de fluorose e com sistemas adesivos sendo que no grupo TF4 foram usados dois tempos condicionamento (15 e 60 segundos). Após profilaxia com pedra-pomes, lavagem e secagem, procedeu-se à aplicação dos sistemas adesivos. e construção de bloco de resina composta Filtek Z250TM (3M ESPE) de 5x5x5mm sobre a superfície tratada. Após 24h, os blocos foram seccionados no sentido X e Y perpendiculares à interface de união, obtendo-se palitos com área aproximada de 1mm2. Os palitos foram submetidos às forças de tração à velocidade de 1mm/min e os valores obtidos à Análise de Variância (p<0,05). As superfícies condicionadas, as réplicas e palitos fraturados foram processados para análise em MEV. Houve diferença estatística significativa entre os adesivos (p = 0,008), sendo que o Single Bond 2® apresentou os maiores valores de resistência de união. A severidade da fluorose não influenciou nos valores de resistência de união, no padrão de condicionamento ou na formação de tags de resina. O aumento do tempo de condicionamento, testado em TF4 influenciou na resistência de união, mostrando menores valores em 60 segundos. Concluiu-se que o adesivo de condicionamento ácido total mostrou-se melhor que o autocondicionante em termos de resistência de união, padrão de condicionamento e penetração de sistemas adesivos, independentemente do grau de fluorose. O aumento do tempo de condicionamento na fluorose mais severa (TF4) prejudicou a resistência de união. / The purpose of this study was to observe the influence of dental fluorosis on the characteristics of the acid etch pattern and penetration of adhesive systems into enamel, by means of scanning electron microscopy (SEM), and on the bond strength of adhesive systems to enamel, through microtensile testing. In order to do so, 196 permanent posterior teeth were classified according to the Thylstrup and Fejerskov Index (TF= 0.1 and 4) and 69 of them were selected. Two-steps adhesive systems, one self-etching, Clearfil SE Bond®, and one total-etching, Adper Single Bond 2®, were used. For SEM analysis of the etch pattern and of the resin replicas, 27 premolars were sectioned mesiodistally and divided into 9 groups (n=3). The buccal surfaces were selected and longitudinally sectioned, using the half for each analysis. Specimens of the phosphoric acid gel at 37% (Magic acid®) group were etched using the two etching times (15 and 60 seconds), washed with air/water for 20 seconds and dried. Specimens of the Clearfil SE Bond® group received application of the material?s primer followed by a treatment to remove it. In order to obtain the resin replicas, the surfaces were outlined (2x2mm) using insulating tape, they were treated with each adhesive and underwent the building of a resin block (Filtek Z250TM ? 3M ESPE Brazil) of 2mm height. These specimens were immersed in 18% HCl for 48 hours and washed with distilled water under ultrasonication for 15 minutes. Microtensile testing was conducted on the intact buccal surface of 42 third molars that were divided into 7 groups and subdivided according to the degree of fluorosis and to the type of adhesive system, being that two etch times (15 and 60 seconds) were used in the TF4 group. After prophylaxis with pumice, washing and drying, the adhesive systems were applied and the composite resin blocks (Filtek Z250TM ? 3M ESPE Brazil) of 5x5mm were built upon a treated surface. After 24 hours, the blocks were sectioned in the X and Y directions perpendicular to the bond interface in order to obtain stick-shaped specimens with an area of approximately 1mm2. The sticks were submitted to tensile forces at a speed of 1mm/min and the values obtained underwent variance analysis (p<0.05). The etched surfaces, the replicas and fractured sticks were processed for analysis by SEM. There was a statistically significant difference between the adhesives (p = 0.008), being that Single Bond 2® presented the highest bond strength values. The severity of fluorosis did not influence the bond strength values, the etch pattern or the formation of resin tags. The increase in etch time, tested in TF4, influenced the bond strength, showing lower values for the 60 seconds time. In conclusion, the total-etch adhesive presented better results than the self-etch one in terms of bond strength, etch pattern and penetration of adhesive systems, regardless of the degree of fluorosis. The increase in etch time for the most severe fluorosis (TF4) cases impaired bond strength.
839

Wear-quantification of textured geomembranes using digital imaging analysis

Zaharescu, Catalin A. January 2018 (has links)
During the past decades there has been an increase in the use of geosynthetics in construction due to their versatility in providing a wide array of functions such as reinforcement, containment, separation, filtration and drainage. Often, geosynthetics are used in conjunction with other geosynthetics to accomplish these functions. However, geosynthetics create possible planes of weakness which can lead to failures. Textured geomembranes are widely used within landfill and mining industries due to their containment and shear strength properties, however, there are subjected to a wide array of loads and environments which are potentially hazardous, as such is of utmost importance to retain their integrity in order to avoid ecological disasters. The challenge is to understand how geomembranes resist damage, wear and which of these factors control the development of wear on textured geomembranes. Digital imaging techniques have been used in order to develop a protocol that describes the quantification of wear on textured structured geomembranes. Direct shear tests were performed to induce wear on the geomembrane textures (asperities) to analyse the wear mechanisms and study the factors that induce wear on the asperities. The research showed that normal stress and shear displacement have a major role in the development of wear on interfaces. However, the geometrical characteristics of the geomembrane asperities control the amount of wear the geomembrane can sustain without significant shear strength loss. These outcomes help to better understand the behaviour of interfaces which have as component geomembranes, leading to more robust designs. This study also proposed new asperity texture shapes by using Rapid Prototyping (RP) techniques, such as Selective Laser Sintering and Fused Filament Fabrication. Using RP techniques to create new textures for the geomembrane, could allow the creation of textures which have increased shear strength thresholds and better withstand wear, allowing for more advanced and economical designs.
840

\"Influência da fluorose dental na resistência de união de sistemas adesivos ao esmalte: análise em microscopia eletrônica de varredura e teste de microtração\" / Influence of dental fluorosis on the bond strength of adhesive system to enamel

Peixoto, Luciana Faria Sanglard 11 December 2006 (has links)
Objetivou-se observar a influência da fluorose dental nas características do padrão de condicionamento ácido e na penetração de sistemas adesivos no esmalte, por microscopia eletrônica de varredura (MEV) e na resistência de união de sistemas adesivos ao esmalte, por teste de microtração. Para tal, 196 dentes permanentes posteriores foram classificados seguindo o Índice Thylstrup e Fejerskov (TF= 0, 1 e 4), sendo selecionados 69 deles. Adesivos de 2 passos, um autocondicionante, Clearfil SE Bond®, e um de condicionamento ácido total, Adper Single Bond 2® foram usados. Para análise em MEV do padrão de condicionamento e das réplicas de resina, 27 pré-molares foram seccionados no sentido mesiodistal e divididos em 9 grupos (n=3). As superfícies vestibulares foram selecionadas e seccionadas no sentido longitudinal, sendo metade para cada análise. Os espécimes pertencentes ao grupo do ácido fosfórico foram condicionados com tempos de 15 ou 60 segundos, lavados com ar/água por 20 segundos e secos. Os espécimes do grupo Clearfil SE Bond® receberam aplicação do primer do material, e em seguida, tratamento para removê-lo. Para obter as réplicas de resina, as superfícies foram delimitadas (2x2mm) com fita isolante, tratadas com cada adesivo, e submetidas à construção de bloco de resina (Filtek Z250TM ? 3M do Brasil) com 2 mm de altura. Esses espécimes foram imersos em HCl a 18% por 48h e lavados com água destilada em ultra-som por 15 minutos. O teste de microtração foi realizado na superfície vestibular intacta de 42 terceiros molares divididos em 7 grupos e subdivididos de acordo com grau de fluorose e com sistemas adesivos sendo que no grupo TF4 foram usados dois tempos condicionamento (15 e 60 segundos). Após profilaxia com pedra-pomes, lavagem e secagem, procedeu-se à aplicação dos sistemas adesivos. e construção de bloco de resina composta Filtek Z250TM (3M ESPE) de 5x5x5mm sobre a superfície tratada. Após 24h, os blocos foram seccionados no sentido X e Y perpendiculares à interface de união, obtendo-se palitos com área aproximada de 1mm2. Os palitos foram submetidos às forças de tração à velocidade de 1mm/min e os valores obtidos à Análise de Variância (p<0,05). As superfícies condicionadas, as réplicas e palitos fraturados foram processados para análise em MEV. Houve diferença estatística significativa entre os adesivos (p = 0,008), sendo que o Single Bond 2® apresentou os maiores valores de resistência de união. A severidade da fluorose não influenciou nos valores de resistência de união, no padrão de condicionamento ou na formação de tags de resina. O aumento do tempo de condicionamento, testado em TF4 influenciou na resistência de união, mostrando menores valores em 60 segundos. Concluiu-se que o adesivo de condicionamento ácido total mostrou-se melhor que o autocondicionante em termos de resistência de união, padrão de condicionamento e penetração de sistemas adesivos, independentemente do grau de fluorose. O aumento do tempo de condicionamento na fluorose mais severa (TF4) prejudicou a resistência de união. / The purpose of this study was to observe the influence of dental fluorosis on the characteristics of the acid etch pattern and penetration of adhesive systems into enamel, by means of scanning electron microscopy (SEM), and on the bond strength of adhesive systems to enamel, through microtensile testing. In order to do so, 196 permanent posterior teeth were classified according to the Thylstrup and Fejerskov Index (TF= 0.1 and 4) and 69 of them were selected. Two-steps adhesive systems, one self-etching, Clearfil SE Bond®, and one total-etching, Adper Single Bond 2®, were used. For SEM analysis of the etch pattern and of the resin replicas, 27 premolars were sectioned mesiodistally and divided into 9 groups (n=3). The buccal surfaces were selected and longitudinally sectioned, using the half for each analysis. Specimens of the phosphoric acid gel at 37% (Magic acid®) group were etched using the two etching times (15 and 60 seconds), washed with air/water for 20 seconds and dried. Specimens of the Clearfil SE Bond® group received application of the material?s primer followed by a treatment to remove it. In order to obtain the resin replicas, the surfaces were outlined (2x2mm) using insulating tape, they were treated with each adhesive and underwent the building of a resin block (Filtek Z250TM ? 3M ESPE Brazil) of 2mm height. These specimens were immersed in 18% HCl for 48 hours and washed with distilled water under ultrasonication for 15 minutes. Microtensile testing was conducted on the intact buccal surface of 42 third molars that were divided into 7 groups and subdivided according to the degree of fluorosis and to the type of adhesive system, being that two etch times (15 and 60 seconds) were used in the TF4 group. After prophylaxis with pumice, washing and drying, the adhesive systems were applied and the composite resin blocks (Filtek Z250TM ? 3M ESPE Brazil) of 5x5mm were built upon a treated surface. After 24 hours, the blocks were sectioned in the X and Y directions perpendicular to the bond interface in order to obtain stick-shaped specimens with an area of approximately 1mm2. The sticks were submitted to tensile forces at a speed of 1mm/min and the values obtained underwent variance analysis (p<0.05). The etched surfaces, the replicas and fractured sticks were processed for analysis by SEM. There was a statistically significant difference between the adhesives (p = 0.008), being that Single Bond 2® presented the highest bond strength values. The severity of fluorosis did not influence the bond strength values, the etch pattern or the formation of resin tags. The increase in etch time, tested in TF4, influenced the bond strength, showing lower values for the 60 seconds time. In conclusion, the total-etch adhesive presented better results than the self-etch one in terms of bond strength, etch pattern and penetration of adhesive systems, regardless of the degree of fluorosis. The increase in etch time for the most severe fluorosis (TF4) cases impaired bond strength.

Page generated in 0.0328 seconds