• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 191
  • 189
  • 33
  • 13
  • 7
  • 6
  • 5
  • 3
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • Tagged with
  • 563
  • 170
  • 118
  • 82
  • 77
  • 72
  • 68
  • 48
  • 44
  • 41
  • 39
  • 38
  • 37
  • 36
  • 34
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
281

Resistência e elasticidade da madeira e de juntas coladas de Eucalyptus grandis W. Hill ex-Maiden e seus impactos na mecânica de vigas laminadas coladas / Strength and elasticity of wood and glued joints of Eucalyptus grandis W. Hill ex Maiden and their impacts on the mechanic of glued laminated beams

Serrano, Luisa Julieth Parra 21 June 2013 (has links)
A presente pesquisa teve como objetivo geral a otimização dos parâmetros de colagem para a fabricação de madeira laminada colada de Eucalyptus grandis, enfatizado na interação madeira-adesivo. Foi avaliada a influência da rugosidade, pressão de colagem, tipo de adesivo e tempo de armazenamento da madeira após a preparação das superfícies a serem coladas. Essas variáveis que afetam a qualidade da adesão foram analisadas a partir da resistência apresentada pelas uniões submetidas ao esforço de cisalhamento. Para complementar a compreensão da mecânica das juntas coladas, efetuou-se a caracterização qualitativa da linha de cola mediante análises microscópicas e imagens de raios-X. Estudaram-se as correlações existentes entre os pares possíveis das variáveis massa específica, resistência ao cisalhamento, rugosidade, profundidade de penetração e porcentagem de falha na madeira. A resistência do plano de cola em situação crítica de cisalhamento foi avaliada também em ensaios de flexão de vigas laminadas coladas. A eficiência adesiva, que é a relação entre a resistência da madeira maciça e a resistência da madeira laminada colada, não variou significativamente entre adesivo, pressão de colagem e acabamento de superfície. A eficiência adesiva das juntas coladas de madeira de Eucalyptus grandis com adesivos Cascophen e Jowapur foi satisfatória por ter estado sempre no intervalo de 90,9 a 127,8%. Observaram-se correlações muito fracas entre a espessura da linha de cola e as variáveis massa específica, resistência ao cisalhamento, eficiência adesiva e porcentagem de falha na madeira. As vigas solidarizadas com o adesivo Jowapur apresentaram um baixo módulo de elasticidade quando comparado ao da madeira maciça, sem apresentar diferenças significativa na resistência à flexão. Os processos de fabricação adotados garantiram uma qualidade ótima às juntas coladas, inferida pela observação das falhas que ocorreram tanto nos ensaios de cisalhamento quanto nos ensaios de flexão, nos quais as rupturas se deram ao longo da madeira maciça sem afetar o plano de cola. / The objective of the present study was to optimize the parameters of glue to manufacture laminated wood of E. grandis, emphasized the interaction wood-adhesive. The influence of the roughness, bonding pressure, adhesive type and time of storage of the timber after preparing the surfaces to be bonded were evaluated. These variables that affect the quality of adherence were analyzed from the resistance presented by the joints subjected to shear stress. To complement the understanding of the mechanics of bonded joints, we performed a qualitative characterization of the glue line by microscopy and X-ray imaging. Were studied correlations between possible pairs of variables: density, shear strength, roughness, depth of penetration, percentage of wood failure. The resistance of the bonding surface in critical shear was also measured using bending tests of glued laminated beams. The adhesive efficiency, which is the ratio between the resistance of the wood and the glued laminated wood resistance, did not vary significantly between adhesive, pressure bonding and surface finish. The adhesive efficiency of the bonded joints of Eucalyptus grandis with Cascophen and Jowapur was satisfactory falling always in the range from 90.9 to 127.8%. Very weak correlations were observed between the variables glue line thickness, density, shear strength, adhesive efficiency and percentage of wood failure. The beams glued with the adhesive Jowapur showed a low modulus of elasticity compared to solid wood, without showing significant differences in flexural strength. The manufacturing processes adopted ensured the optimal quality of bonded joints. This was inferred by observing the failures that occurred in both shear tests as in bending tests. Ruptures occurred within the wood without affecting the bonding surface.
282

Cola adesiva cirúrgica no reparo de lacerações perineais de primeiro grau no parto normal: estudo piloto aleatorizado controlado / Tissue adhesive for first-degree perineal tears repairing during normal delivery: a pilot randomized controlled trial

Teixeira, Thaís Trevisan 22 March 2018 (has links)
Introdução: O trauma perineal provocado pelo parto vaginal e seu reparo são importantes preocupações relacionadas ao períneo. A técnica ideal de reparo deve ser rápida, indolor, de fácil execução e que reduza a dor no puerpério. As evidências científicas apontam que a técnica e o material mais adequados para o reparo do trauma perineal são a sutura contínua e o fio poliglactina 910 de rápida absorção. Entretanto, em lacerações de primeiro e segundo graus, apesar de promover boa cicatrização, a sutura está relacionada à dor no períneo. A cola adesiva cirúrgica é um material utilizado em diversas cirurgias e especialidades médicas, com alto grau de resistência e facilidade no procedimento cirúrgico, o que parece se apresentar como uma alternativa eficaz no reparo perineal. Objetivo: Determinar a viabilidade de um ensaio clínico controlado e aleatorizado (ECA) sobre o uso da cola adesiva cirúrgica no reparo de lacerações perineais de primeiro grau durante o parto normal. Método: Estudo piloto paralelo, controlado e aleatorizado comparando a cola adesiva cirúrgica Epiglu® (etil-2-cianoacrilato) com o fio Vicryl Rapide® (poliglactina 910) no reparo perineal, realizado no Pronto Socorro e Maternidade Municipal Zoraide Eva das Dores, Itapecerica da Serra-SP. A amostra foi constituída por 20 mulheres com lacerações perineais de primeiro grau com necessidade de reparo durante o parto normal, distribuídas no grupo experimental (GE; n=10; submetidas ao reparo com Epiglu®) e grupo controle (GC; n=10; submetidas ao reparo com sutura com Vicryl Rapide®). O desfecho primário foi a ocorrência e intensidade da dor perineal após o parto e os desfechos secundários foram o processo de cicatrização, a satisfação da mulher com reparo perineal e o tempo dispendido pelo profissional para o reparo. Os desfechos foram avaliados pela Escala Visual Numérica de 11 pontos para intensidade da dor perineal; Escala REEDA, para cicatrização perineal; Escala Visual Analógica para satisfação da mulher; cronômetro digital para contagem do tempo de reparo dispendido em ambas as técnicas. Os dados foram coletados em quatro etapas: até 2 horas pós-parto, 12-24 horas, 36-48 horas e 10-20 dias pós-parto. Resultados: A média da intensidade da dor perineal foi significativamente menor entre as mulheres no GE, em todas as etapas do estudo (variação de 2,0-0,2 e 2,5-0,6 nos GE e GC, respectivamente). A cicatrização perineal apresentou escores significativamente melhores na escala REEDA entre as mulheres no GE, em todas as etapas (variação de 0,6-0,0 e 1,8-0,7, nos GE e GC, respectivamente). A satisfação das mulheres com reparo perineal foi significativamente superior no GE (100% estavam satisfeitas ou muito satisfeitas), em comparação com o GC (10% a 20% estavam insatisfeitas ou muito insatisfeitas). A média de tempo gasto para o reparo perineal foi 5 minutos no GE e 21 minutos no GC (p<0,001). Conclusão: O estudo mostrou que é viável adotar a técnica de reparo com Epiglu® utilizada no estudo piloto, bem como os mesmos desfechos e períodos de seguimento pós-parto. Além disso, os resultados foram importantes para comparar os métodos de reparo perineal e calcular o tamanho da amostra para o ECA. Protocolo: O estudo foi registrado no Portal de Registro Brasileiro de Ensaios Clínicos http://www.ensaiosclinicos.gov.br/rg/RBR-2h84gt/ / Introduction: One of the important concerns regarding the perineum is the trauma caused by the vaginal delivery and perinealrepair. The ideal perineal repair technique should be quick, painless, easy to perform in order to decrease pain in the puerperium. The scientific evidence indicates that the most suitable technique and material for the repair of perineal trauma are continuous suture and the polyglactin 910 rapid absorption thread. However, in the first and second degrees lacerations, despite promoting good healing, the suture is associated with perineum pain. The surgical adhesive is a tool used in several surgeries and medical specialties, had high resistance and is ease to manage during the surgical procedure, which seems to be an effective alternative for perineal repair. Objective: To determine the feasibility of a clinical randomized controlled trial (RCT) on the use of surgical adhesive in the repair of first-degree perineal trauma during vaginal delivery. Methods: Parallel, controlled and randomized pilot study comparing the outcomes of the use of surgical adhesive glue Epiglu (ethyl-2-cyanoacrylate) and Vicryl Rapide (polyglactin 910) thread in perineal repair. The research was performed at Pronto Socorro e Maternidade Zoraide Eva das Dores, Itapecerica da Serra-SP, Brazil. The sample comprised 20 women with first-degree perineal trauma that need repair during normal delivery, distributed in experimental group (EG, n=10, undergoing repair with Epiglu) and control group (CG;n=10, undergoing repair with Vicryl Rapide). The primary outcome was the occurrence and intensity of perineal pain after delivery and secondary outcomes were healing process, the womans satisfaction on perineal repair and the time spent by the professional to repair the trauma. The outcomes were evaluated by the 11-point Visual Numeric Scale for perineal pain intensity; REEDA Scale for perineal healing; Visual Analogue Scale for womens satisfaction; digital stopwatch for counting the repair time in both suture techniques. Data were collected in four stages: up to 2 hours after delivery, 12-24 hours, 36-48 hours and 10-20 days postpartum. Results: In all study stages, the average of the intensity of perineal pain among women in EG was significantly lower than CG (variation of 2.0-0.2 in EG and 2.5-0.6 in CG). In all stages, perineal healing showed significantly better REEDA scale scores among women in EG, (variation of 0.6-0.0 in EG and 1.8-0.7 in CG). The womens satisfaction with perineal repair was significantly higher in EG (100% were satisfied or very satisfied), compared with CG (10% to 20% were unsatisfied or very unsatisfied). The average time for perineal repair was 5 minutes in EG and 21 minutes in CG (p<0.001). Conclusion: The results of the study were important to compare perineal repair methods and calculate the sample size for the future RCT. In addition, we showed that is possible to adopt the perineal repair technique with Epiglu developed in the pilot study, as well as the same outcomes and postpartum follow-up periods. Protocol: The study was registered in the Brazilian Clinical Trials Registry http://www.ensaiosclinicos.gov.br/rg/RBR-2h84gt/
283

Influência da utilização de um adesivo no período de adaptação com próteses totais em pacientes com rebordos normais e reabsorvidos /

Silva, Marcela Dantas Dias Da January 2019 (has links)
Orientador: Ana Carolina Pero Vizoto / Resumo: O objetivo deste estudo foi avaliar o efeito do adesivo tipo pó no desempenho mastigatório e qualidade de vida associada à saúde bucal (QVSB) de pacientes edêntulos com rebordos mandibulares normais e reabsorvidos, durante o período de adaptação com próteses totais convencionais. Quarenta e dois indivíduos desdentados totais completaram o estudo, sendo assim distribuídos: participantes com rebordos normais com adesivo, 10; participantes com rebordos normais sem adesivo, 10; participantes com rebordos reabsorvidos com adesivo, 11; participantes com rebordos reabsorvidos sem adesivo, 11. Nos grupos com adesivo, os participantes foram orientados a utilizar o adesivo Corega pó durante o período do estudo, de acordo com as recomendações do fabricante. O desempenho mastigatório foi avaliado através do método dos tamises e a QVSB dos indivíduos usuários de próteses totais foi avaliada através do questionário Oral Health Impact Profile específico para pacientes desdentados totais (OHIP-EDENT), nos períodos 30, 60 e 90 dias após a instalação das próteses totais. Os dados foram submetidos ao teste de ANOVA dois fatores mista (desempenho mastigatório) e Equações de Estimações Generalizadas (QVSB), de acordo com o tipo de rebordo (α=0,05). Os resultados mostraram que o uso do adesivo resultou em melhor desempenho mastigatório no período de 30 (35,76±12,63% A) e 60 dias (30,06±10,54% A), para participantes com rebordos normais, em comparação com o período 90 dias (23,53±9,74% B). O uso de... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: This study evaluated the effect of powder adhesive on masticatory performance and oral health related quality of life (OHRQoL) in complete denture wearers with normal and resorbed mandibular ridges during adaptation period. Forty-two participants were distributed in four groups: normal mandibular ridges with adhesive, n=10; normal mandibular ridges without adhesive, n=10; resorbed mandibular ridges with adhesive, n=11; resorbed mandibular ridges without adhesive, n=11. Participants used Corega powder during the study according to the manufacturer's recommendations. The masticatory performance was evaluated using sieve method and OHRQoL was assessed by the Oral Health Impact Profile in Edentulous Adults (OHIP-EDENT) inventory at 30, 60 and 90 days after insertion of new complete dentures. Data were submitted to the 2-way ANOVA test (masticatory performance) and Generalized Estimating Equations (OHRQoL), according to the type of ridges (α=.05). The results showed that the use of adhesive resulted in a better masticatory performance at 30 (35.76±12.63% A) and 60 days (30.06±10.54% A) for participants with normal mandibular ridges than the 90-day period (23.53±9.74% B). The use of adhesive did not interfere on masticatory performance of participants with resorbed mandibular ridges during adaptation period with new complete dentures and had a negative effect on masticatory discomfort/disability OHRQoL subscale for participants with resorbed mandibular ridges at 30-day period [5.2(3.6, 6.8)] compared to 60 [2.6(0.9, 4.3)] and 90 days periods [1.7(0.2, 3.2)]. The use of adhesive did not influence OHRQoL in participants with normal mandibular ridges during adaptation period with new complete dentures. It was concluded that use of adhesive can improve the masticatory performance of new complete dentures wearers with normal mandibular...(Complete abstract electronic access below) / Mestre
284

Resistência e elasticidade da madeira e de juntas coladas de Eucalyptus grandis W. Hill ex-Maiden e seus impactos na mecânica de vigas laminadas coladas / Strength and elasticity of wood and glued joints of Eucalyptus grandis W. Hill ex Maiden and their impacts on the mechanic of glued laminated beams

Luisa Julieth Parra Serrano 21 June 2013 (has links)
A presente pesquisa teve como objetivo geral a otimização dos parâmetros de colagem para a fabricação de madeira laminada colada de Eucalyptus grandis, enfatizado na interação madeira-adesivo. Foi avaliada a influência da rugosidade, pressão de colagem, tipo de adesivo e tempo de armazenamento da madeira após a preparação das superfícies a serem coladas. Essas variáveis que afetam a qualidade da adesão foram analisadas a partir da resistência apresentada pelas uniões submetidas ao esforço de cisalhamento. Para complementar a compreensão da mecânica das juntas coladas, efetuou-se a caracterização qualitativa da linha de cola mediante análises microscópicas e imagens de raios-X. Estudaram-se as correlações existentes entre os pares possíveis das variáveis massa específica, resistência ao cisalhamento, rugosidade, profundidade de penetração e porcentagem de falha na madeira. A resistência do plano de cola em situação crítica de cisalhamento foi avaliada também em ensaios de flexão de vigas laminadas coladas. A eficiência adesiva, que é a relação entre a resistência da madeira maciça e a resistência da madeira laminada colada, não variou significativamente entre adesivo, pressão de colagem e acabamento de superfície. A eficiência adesiva das juntas coladas de madeira de Eucalyptus grandis com adesivos Cascophen e Jowapur foi satisfatória por ter estado sempre no intervalo de 90,9 a 127,8%. Observaram-se correlações muito fracas entre a espessura da linha de cola e as variáveis massa específica, resistência ao cisalhamento, eficiência adesiva e porcentagem de falha na madeira. As vigas solidarizadas com o adesivo Jowapur apresentaram um baixo módulo de elasticidade quando comparado ao da madeira maciça, sem apresentar diferenças significativa na resistência à flexão. Os processos de fabricação adotados garantiram uma qualidade ótima às juntas coladas, inferida pela observação das falhas que ocorreram tanto nos ensaios de cisalhamento quanto nos ensaios de flexão, nos quais as rupturas se deram ao longo da madeira maciça sem afetar o plano de cola. / The objective of the present study was to optimize the parameters of glue to manufacture laminated wood of E. grandis, emphasized the interaction wood-adhesive. The influence of the roughness, bonding pressure, adhesive type and time of storage of the timber after preparing the surfaces to be bonded were evaluated. These variables that affect the quality of adherence were analyzed from the resistance presented by the joints subjected to shear stress. To complement the understanding of the mechanics of bonded joints, we performed a qualitative characterization of the glue line by microscopy and X-ray imaging. Were studied correlations between possible pairs of variables: density, shear strength, roughness, depth of penetration, percentage of wood failure. The resistance of the bonding surface in critical shear was also measured using bending tests of glued laminated beams. The adhesive efficiency, which is the ratio between the resistance of the wood and the glued laminated wood resistance, did not vary significantly between adhesive, pressure bonding and surface finish. The adhesive efficiency of the bonded joints of Eucalyptus grandis with Cascophen and Jowapur was satisfactory falling always in the range from 90.9 to 127.8%. Very weak correlations were observed between the variables glue line thickness, density, shear strength, adhesive efficiency and percentage of wood failure. The beams glued with the adhesive Jowapur showed a low modulus of elasticity compared to solid wood, without showing significant differences in flexural strength. The manufacturing processes adopted ensured the optimal quality of bonded joints. This was inferred by observing the failures that occurred in both shear tests as in bending tests. Ruptures occurred within the wood without affecting the bonding surface.
285

Estudo do comportamento de argamassas colantes com aditivação de látex acrílico. / Study of behavior of dry set mortar modified with acrylic latex.

Matsusato, Marcelo 24 July 2007 (has links)
Os revestimentos cerâmicos aderidos têm grandes vantagens estéticas e funcionais e seu emprego no mercado nacional vem sendo crescente, sobretudo com o uso de placas de porcelanato. Essas vantagens somente se concretizam com uma adequada durabilidade e vida útil, o que não vem ocorrendo com esses revestimentos aplicados em bases sujeitas a deformações e ou movimentações, como o caso de fachadas. Como camada de ligação entre o substrato e a placa cerâmica, as argamassas colantes apresentam papel fundamental para o revestimento cerâmico, tais como: suportar deformações e ou movimentações diferenciais, apresentar resistência mecânica duradoura e ter capacidade de aderir com segurança em qualquer substrato e placa cerâmica. O objetivo desse trabalho foi de estudar o comportamento de argamassas colantes com a aditivação de látex acrílico. Foi realizado um estudo experimental comparativo entre argamassas colantes monocomponentes e argamassas colantes aditivadas com látex acrílico. Para verificar o comportamento que essa aditivação proporciona, foram realizados ensaios de resistência de aderência, flexibilidade, resistência à compressão, resistência à tração na flexão com determinação de módulo de deformação e tempo em aberto com placas de porcelanato. Os resultados mostraram de uma forma geral que a aditivação de argamassas colantes proporcionam aumento significativo na flexibilidade. Ocorre melhora na resistência de aderência, resistência à compressão e resistência à tração na flexão e também na capacidade de absorver deformações com o aumento do teor de polímero/argamassa. A aderência em placas de baixa porosidade como o porcelanato é melhorada e o tempo em aberto de laboratório também é estendido para as argamassas modificadas com látex. / The directed adhere ceramic tiles has aesthetic and functional advantages, and its use in the national market is increasing specially with the use along with porcelain tile. These advantages can only be seen though, if the system has adequate durability and service live, which doesn\'t happen once it is applied on irreversible or cyclic movement basis as building façades. As the clingy layer between the ceramic tile and the substrate, the tile adhesives have fundamental importance for the directed adhered ceramic tile, working on deformation and movements support capability, long-term durability mechanic resistance and safety and reliability to adhere on all type of substrates and ceramic tile. The purpose of this work was to study the behavior of dry set mortar modified with acrylic latex. An experimental study has been done, comparing dry set mortar to acrylic latex Portland cement mortar. To verify the behavior that the latex provides, the following tests were realized: tensile bond adhesion, deformability, compressive strength and tensile strength with deformation modulus and open time with porcelain tile. The results showed in general, that the latex improved the flexibility of dry set mortar and the improvement of the tensile adhesion, compressive and tensile strength and deformability capacity by increasing the polymer/mortar content. The adhesion and open time in porcelain tile has been improved with latex Portland cement mortar.
286

AVALIAÇÃO DA INCORPORAÇÃO DE CLOREXIDINA EM SISTEMAS ADESIVOS NA LIBERAÇÃO E SEUS EFEITOS NA LONGEVIDADE DA INTERFACE DE UNIÃO À DENTINA / Evaluation of chlorhexidine incorporation in adhesive systems in the release and their effects on longevity of resin-dentin interface

Malaquias, Pamela 23 February 2016 (has links)
Made available in DSpace on 2017-07-24T19:22:03Z (GMT). No. of bitstreams: 1 PAMELA MALAQUIAS.pdf: 1459467 bytes, checksum: dad45846f48d6409e23619b883575953 (MD5) Previous issue date: 2016-02-23 / The aim of the study was to evaluate the effects of adding chlorhexidine diacetate (CHX), in two different simplified adhesive systems on the chlorhexidine release (CHXR), bond strength (μTBS) and nanoleakage (NL). The CHX was added to adhesive systems XP Bond [XP] (Dentsply, York, PA, USA) and Ambar [AM] (Prod Odont Ltda FGM, Joinville, Brazil) at concentrations of 0 (control); 0.01; 0.05; 0.1 to 0.2% wt. To assess the cumulative CHXR, adhesives disks (n = 10 for each group) were prepared in a metallic matrix (5.8 mm x 1.0 mm) and stored in distilled water. Spectrophotometric measurements of the storage solution were performed to examine the kinetics of release of CHX. For μTBS and NL 50 extracted third molars were used and they had a flat surface of dentin exposed, and were randomly divided according to the different experimental groups mentioned above. This was followed by clinical sequence specified by the manufacturer of each adhesive system. After applying the adhesive, resin composite restorations was built in layers. Then, the specimens were prepared and subjected to microtensile and nanoleakage testing at 24 and 24 months of storage in water at 37°C. For CHXR (% and mg/g), the data of each adhesive were subjected to a two-way ANOVA. The μTBS data (MPa) and NL (%) of each adhesive were submitted to analysis of variance of two factors (ANOVA). The Tukey test was used for pairwise comparisons (α = 0.05). Regarding CHXR, Ambar showed a slower and gradual release of CHX while XP Bond released CHX more quickly. In μTBS, Ambar showed better values in percentage of bond strength reduction after 2 years of storage in water. Both adhesives showed better bond strength values in groups containing CHX compared to the control group (without CHX). In NL, the control group had a higher nanoleakage in 2 years. XP had a higher nanoleakage that Ambar in all groups. We concluded that the addition of CHX diacetate until 0.2% is a viable method of providing a long-term increase in the stability of resin-dentin interfaces without compromising the properties of the adhesives systems. / O objetivo do estudo foi avaliar os efeitos da adição de diacetato de clorexidina (CHX), em dois diferentes sistemas adesivos simplificados na resistência de união (RU), nanoinfiltração (NI) e liberação de clorexidina (LCHX). A CHX foi adicionada aos sistemas adesivos XP Bond [XP] (Dentsply) e Ambar [AM] (FGM) nas concentrações: 0% (controle); 0,01%; 0,05%; 0,1% e 0,2% em peso. Para RU e NI, foram utilizados 50 terceiros molares extraídos que tiveram uma superfície plana de dentina exposta, e foram divididos aleatoriamente de acordo com os diferentes grupos experimentais anteriormente citados. Seguiu-se a sequência clínica indicada pelo fabricante de cada sistema adesivo. Após a aplicação do adesivo, foram confeccionadas restaurações de resina composta pela técnica incremental. Em seguida, os espécimes foram preparados e submetidos a testes de microtração e nanoinfiltração em 24 horas e 2 anos de armazenamento em água a 37ºC. Para avaliação da liberação cumulativa de CHX, discos de adesivos (n = 10 para cada grupo) foram preparados em uma matriz metálica (5,8 mm x 1,0 mm) e armazenados em água destilada. Mensurações espectrofotométricas da solução de armazenamento foram realizadas para examinar a cinética da liberação de CHX. Para liberação de CHX (% e mg/g), os dados de cada adesivo foram submetidos a um ANOVA de duas vias. Os dados de RU (MPa) e NI (%) de cada adesivo foram submetidos à análise de variância de dois fatores (ANOVA). O teste de Tukey foi utilizado para comparações de pares (α = 0,05). Na RU, Ambar apresentou valores melhores na porcentagem de redução da resistência de união após 2 anos de armazenamento em água. Ambos os adesivos apresentaram melhores valores de resistência de união nos grupos contendo CHX, quando comparados ao grupo controle (sem CHX). Na NI, os grupos controle apresentaram uma maior nanoinfiltração no período 2 anos. XP apresentou maior nanoinfiltração que Ambar em todos os grupos. Quanto à LCHX, Ambar apresentou uma liberação mais lenta e gradativa enquanto que XP Bond liberou CHX mais rapidamente. Concluiu-se que a adição de diacetato de CHX até 0,2% é um método viável para proporcionar um aumento em longo prazo da estabilidade das interfaces resina-dentina, sem comprometer as propriedades dos sistemas adesivos.
287

EFEITO DO FLÚOR E TEMPOS DE ESPERA NA RESISTÊNCIA DE UNIÃO E GRAU DE CONVERSÃO DE UM ADESIVO APLICADO EM ESMALTE CLAREADO / Effect of fluoride and time intervals on bond strength and degree of conversion of an adhesive applied on bleached enamel

Bittencourt, Bruna Fortes 23 February 2012 (has links)
Made available in DSpace on 2017-07-24T19:22:16Z (GMT). No. of bitstreams: 1 BRUNA BITTENCOURT.pdf: 1452228 bytes, checksum: d0551e7b763059ec2adf67898ca3066d (MD5) Previous issue date: 2012-02-23 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / The objective of this study was to evaluate the influence of fluoride and time intervals on the bond strength (BS) and degree of conversion (DC) of an adhesive applied on bleached enamel. Sixty human enamel specimens were used, entrenched in PVC tubes and acrylic resin, and submitted to bleaching treatment (n=18): Group HP: HP Maxx (35% hydrogen peroxide); Group HPF: HP Maxx + 1,23% neutral fluoride application; Group PF: Opalescence Boost PF (38% hydrogen peroxide containing 1,1% fluoride). For the restorative procedure, the groups were subdivided into three subgroups (n=6), according to the time interval: immediately, after 7 and 14 days. Tygon tubes were filled with composite resin and positioned on the enamel surface, in order to perform the microshear bond test. DC was observed in Raman spectroscopy. BS (MPa) and DC (%) data were submitted to 2-way ANOVA and Tukey’s post-test, and ANOVA and Dunnet’s post-test (α=0,05). The BS results showed differences between the Group HP in 14 days (21.40±3.45) compared to the groups “immediate” (13.02±4.28) and 7 days (13.67±2.92), the same as verified in Group HPF (14 days: 18.08±2.74, immediate”: 9.74±2.11 and 7 days: 12.66±2.68). For DC, “immediate” Group HP and Group HPF (57.02±7,61 e 66.89±8,57, respectively) differed significantly from 7 and 14 days (HP: 78.15±6.80, HPF: 78.62±8.67 and HP: 77.27±4.60, HPF: 88.09±5.83, espectively). For Group PF, there were no differences between the experimental groups and the control group (p>0.05). It was concluded that fluoride topical application was not effective to reverse low BS and DC values, being necessary wait 14 days to perform the adhesive procedure; but when restorative procedures are required immediately after bleaching, the fluoridated bleaching agent was efficient to maintain BS and DC values. / O objetivo desse estudo foi avaliar a influência do flúor e dos tempos de espera nos valores de resistência de união (RU) e no grau de conversão (GC) de um adesivo aplicado em esmalte clareado. Foram utilizados 60 espécimes de esmalte humano, embutidos em tubos de PVC e resina acrílica e submetidos ao tratamento clareador (n=18): Grupo HP: HP Maxx (peróxido de hidrogênio 35%); Grupo HPF: HP Maxx +aplicação tópica de flúor neutro 1,23%; Grupo PF: Opalescence Boost PF (peróxido de hidrogênio 38% contendo flúor 1,1%). Para o procedimento restaurador, os grupos foram subdivididos em 3 subgrupos (n=6), de acordo com o tempo de espera: imediatamente, 7 e 14 dias. Tubos tygon foram preenchidos por resina composta e posicionados na superfície de esmalte, para ser realizado o teste de microcisalhamento. O GC foi verificado em espectroscopia Raman. Os dados de RU (MPa) e GC (%) foram submetidos à análise de variância de 2 fatores e pós-teste de Tukey, e análise de variância de 1 fator e pós-teste de Dunnet (α=0,05). Os resultados de RU mostraram diferença entre o Grupo HP 14 dias (21,40±3,45), em relação aos grupos “imediato” (13,02±4,28) e 7 dias (13,67±2,92), da mesma forma que o Grupo HPF (14 dias: 18,08±2,74; “imediato”: 9,74±2,11 e 7 dias: 12,66±2,68). Para o GC, o Grupo HP e HPF “imediato” (57,02±7,61 e 66,89±8,57, respectivamente) diferiram estatisticamente dos tempos 7 e 14 dias (HP:78,15±6,80, HPF:78,62±8,67 e HP:77,27±4,60, HPF:88,09±5,83, respectivamente). Para o Grupo PF, não existiram diferenças entre os grupos experimentais e o grupo controle (p>0,05). Concluiu-se que a aplicação tópica de flúor não foi eficiente para reverter os baixos valores de RU e GC, sendo necessário aguardar 14 dias para se realizar o procedimento adesivo; quando da realização de restaurações imediatamente após o clareamento, o agente clareador fluoretado se mostrou eficiente na manutenção dos valores de RU e GC. Palavras-chave: Clareamento Dental. Peróxido de Hidrogênio. Adesivos Dentários.
288

Efeito da aplicação de primers experimentais à base de flavonoides nas propriedades adesivas e mecânicas da dentina hígida e afetada por cárie / Effect of the application of experimental flavonoidprimers over the adhesive and mechanical properties of sound and artificially induced caries-affected dentin

Sánchez, Carlos Andrés Dávila 07 December 2017 (has links)
Submitted by Eunice Novais (enovais@uepg.br) on 2018-02-05T16:22:24Z No. of bitstreams: 2 license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5) Carlos Dávila Sánchez.pdf: 22396898 bytes, checksum: 5122ed06da0d2dc71b9cbf4253c97cda (MD5) / Made available in DSpace on 2018-02-05T16:22:24Z (GMT). No. of bitstreams: 2 license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5) Carlos Dávila Sánchez.pdf: 22396898 bytes, checksum: 5122ed06da0d2dc71b9cbf4253c97cda (MD5) Previous issue date: 2017-12-07 / O objetivo deste estudo foi avaliar o efeito da aplicação de primers experimentais à base de flavonoides na resistência de união, nanodureza, módulo de elasticidade e micromorfologia da interface adesiva criada em dentina hígida e dentina afetada por cárie utilizando um adesivo universal aplicado em modo convencional. Superfícies planas de dentina foram expostas em 182 molares permanentes. Noventa e um molares foram armazenados em água, enquanto os outros 91 foram imersos em uma solução de BHI/Sacarose (pH 4.0) e cepas de Streptococcus mutans por 14 dias para induzir lesões artificiais de cárie em dentina. Quarenta e nove dentes foram aleatoriamente alocados em 7 grupos (n=7) de acordo com o primer experimental usado em cada tipo de substrato (hígido ou afetado por cárie): Controle, sem aplicação de primer (CON), Placebo solução hidroalcoólica com tensoativo (PLA), Proantocinidina (PRO), Quercetina (QER), Naringina (NAR), Rutina (RUT), e Hesperidina (HES). Após o condicionamento, lavagem e secagem das superfícies de dentina, os primers foram ativamente aplicados por 1 min para reumedecer a dentina. Após serem restaurados, os espécimes foram seccionados no seu longo eixo até obter palitos retangulares (0,9 mm2) que foram testados em tração com velocidade de 1 mm/min, tanto após 24 h quanto após 25.000 ciclos em uma máquina de ciclagem térmica (5 ºC / 55 ºC). Para os testes de nanodureza e módulo de elasticidade (n=3), os espécimes foram cortados longitudinalmente até obter duas fatias planas (1,2 mm) e foram analisados em um nanoindentador com uma ponta Berkovich tanto após 24 h quanto após 25.000 ciclos térmicos. Para a análise qualitativa de microinfiltração, 21 dentes (n=3) assistida por corantes em Microscópio confocal (CSLM), o adesivo e a resina composta foram misturados com 0,2% de Rhodamina B (massa) antes dos procedimentos restauradores e duas fatias planas foram obtidas para análise após 24 h e 25.000 ciclos térmicos. As fatias foram imersas em uma solução de Fluoresceína (0,1%) por 4 horas. Quatro imagens da interface adesiva de cada dente foram obtidas em cada momento experimental (24 h ou 25.000 ciclos) a 5 e 10 μm de profundidade. Os resultados foram analisados usando uma análise de variância de medidas repetidas e pós-teste de Bonferroni (= 0,05). Resultados: Os grupos PLA e RUT mostraram os valores mais altos de μTBS em dentina hígida em ambos intervalos (p > 0,05). Na dentina afetada por cárie os grupos RUT e NAR apresentaram os valores mais altos em ambos intervalos. As imagens de CSLM mostraram sinais de infiltração em todos os grupos. PLA, RUT, NAR e PRO mostraram áreas sem infiltração em ambos intervalos e tipo de substrato. As nanopropriedades foram influenciadas pelos grupos experimentais em profundidade dependendo do flavonoide usado. Conclusão: O uso de flavonoides poderia ser uma alternativa terapêutica em dentina hígida e afetada por cárie para melhorar as propriedades e longevidade da interface adesiva. / The aim of this study was to evaluate the effect of experimental flavonoid primers on bond strength, nanohardness, elastic modulus, and micromorphology of bonding interfaces created on sound and caries-affected dentin using one commercially available universal bonding agent applied in the etch-and-rinse mode. Flat midcoronal dentin surfaces were exposed in 182 permanent molars. Ninety-one molars were stored in water while the other 91 molars were kept in a BHI/Sucrose solution (pH 4.0) with Streptococcus mutans strain for 14 days to induce artificial caries-affected dentin. Forty-nine teeth were randomly assigned to 7 groups (n=7) according to the experimental primer applied to each dentin surface condition (sound or caries-affected dentin): Control, in which no primer was applied (CON), Hydroalcoholic solution with surfactant Placebo (PLA), Proanthocianidin (PRO), Quercetin (QER), Naringin (NAR), Rutin (RUT) and Hesperidin (HES). After etching, rinse and drying the dentin surfaces, the primers were actively applied for 1 min to rewet the dentin surface. After bonding and restorative procedures, specimens were sectioned in the long axis to obtain rectangular sticks (0.9 mm2) that were subjected to microtensile tests (μTBS) at a crosshead speed of 1 mm/min, either 24 h or after 25.000 cycles in a thermocycling machine (5ºC / 55ºC). For nanohardness and elastic modulus (n=3), the specimens were longitudinally sectioned to obtain 2 flat silces (1,2 mm) and were analyzed in a nanohardness device with a Berkovich indenter either after 24 h or after 25.000 (5 ºC / 55 ºC) thermal cycles. For the dye assisted microinfiltration qualitative analysis 21 teeth (n=3) was performed with a Confocal Scanning Laser Microscope (CSLM), both adhesive system and resin composite were mixed with 0.2% (weight) Rhodamine B prior to the restorative procedure and two flat slices were obtained for analysis in 24 h and after 25.000 thermal cycles. The bonding interfaces were immersed in a 0,1%. Fluorescein solution for 4 hours. Four images of bonding interface per specimen where obtained in each experimental time (24 h and 25.000 cycles) at 5 and 10 m depth. The data were analyzed using two-way repeated measures ANOVA and Bonferroni post-hoc test ( = 0.05). Results. PLA and RUT showed the highest TBS values in sound teeth at both intervals (24h and ageing) (p>0.05), while RUT and NAR showed the highest TBS values in carious teeth in both stages. CLSM analysis showed signs of microinfiltration for all groups. PLA, RUT, NAR and PRO showed areas of no infiltration in both experiments and intervals. Nanomechanical properties were influenced by experimental groups in deep, dependending on the flavonoid used. Conclusion: The use of flavonoids may be an alternative for therapeutic substances in sound or carious dentin to improve their properties and longevity in the adhesive interphase.
289

Avaliação clínica de 12 meses de um sistema adesivo universal contendo cobre em restaurações de lesões cervicais não-cariosas: ensaio clínico randomizado triplo cego / A 12-month clinical evaluation of a copper-containing universal adhesive system for restorations of non-carious cervical lesions: a triple blind randomized clinical trial

Matos, Thalita de Paris 20 February 2018 (has links)
Submitted by Eunice Novais (enovais@uepg.br) on 2018-07-24T13:03:39Z No. of bitstreams: 2 license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5) Thalita Paris Matos.pdf: 2830475 bytes, checksum: 4772e79fc35ae4727e3ca7ca58605b0a (MD5) / Made available in DSpace on 2018-07-24T13:03:39Z (GMT). No. of bitstreams: 2 license_rdf: 811 bytes, checksum: e39d27027a6cc9cb039ad269a5db8e34 (MD5) Thalita Paris Matos.pdf: 2830475 bytes, checksum: 4772e79fc35ae4727e3ca7ca58605b0a (MD5) Previous issue date: 2018-02-20 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Partículas de cobre tem sido incorporadas em materiais resinosos com o objetivo de conferir efeito antimicrobiano e aumentar a longevidade da interface adesiva. Este estudo avaliou o efeito de um sistema adesivo universal (Ambar – FGM) contendo nanopartículas de cobre na concentração de 0,1% utilizado nas estratégias convencional (etch-and-rinse - ER) e autocondicionante (self-etch - SE), em restaurações em resina composta de lesões cervicais não-cariosas (LCNC). Trinta e seis pacientes participaram desse estudo. Duzentas e dezesseis restaurações foram aleatoriamente divididas em 4 grupos (n = 54): 1) Estratégia convencional com adição de 0,1% de cobre (ER-CP); 2: Estratégia convencional sem adição de cobre (ER-CT); 3: Estratégia autocondicionante com adição de 0,1% de cobre (SE-CP); 4: Estratégia autocondicionante sem adição de cobre (SE-CT). A resina composta nanohíbrida (Opallis – FGM) foi inserida em 3 incrementos. As avaliações foram feitas seguindo os critérios FDI e USPHS, nos períodos imediato (imediatamente, logo após procedimento restaurador), 6 e 12 meses. As diferenças nos critérios avaliados entre os 4 grupos após cada tempo (imediato vs. 6 meses, imediato vs. 12 meses e 6 meses vs 12 meses) foram submetidas ao teste de Friedman (α= 0,05) e o desempenho dos mesmos em cada tempo dos diferentes grupos foi avaliado pelo teste de Wilcoxon (α= 0,05). Após 12 meses, o adesivo universal com adição de nanoparticulas de cobre mostrou-e similar ao adesivo universal sem cobre, nas taxas de retenção, em ambas as estratégias de adesão, no modo autocondicionante e convencional. De acordo com o critério FDI, todos os grupos apresentaram pequenas discrepâncias na adaptação marginal, sendo que o grupo convencional teve melhores resultados do que o grupo autocondionante. / Copper particles have been incorporated in resinous materials with the aim of conferring antimicrobial effect and increasing the longevity of the adhesive interface. This study evaluated the effect of a universal adhesive system containing copper nanoparticles at 0,1% using etch-and-rinse (ER) and self-etch (SE) strategies for restorations of non-carious cervical lesions (LCNC). Thirty-six patients participated in this study. Two hundred and sixteen restorations were divided into 4 groups (n = 54): 1) Etch-and-rinse strategy with 0.1% copper (ER-CP); 2: Etch-and-rinse strategy without copper (ER-CT); 3: Self-etching strategy with 0.1% copper (SE-CP); 4: Self-etching strategy without copper (SE-CT). The nanohybrid composite resin was inserted in 3 increments. The evaluations were carried out according to the FDI and USPHS criteria at baseline (immediately, soon after restorative procedure), 6 and 12 months. The data were submitted to statistical analysis. The differences in the criteria evaluated between the 4 groups after each time (baseline vs. 6 months, baseline o vs. 12 months and 6 months vs 12 months) were submitted to the Friedman test (α = 0.05) and the performance of the different groups at each time was evaluated by the Wilcoxon test (α = 0.05). After 12 months, retention of the universal adhesive with addition of copper nanoparticles was similar when compared with the copper-free adhesive both in the etch-and-rinse and self-etching modes. According to the FDI criterion, all groups presented small discrepancies in the marginal adaptation, and the etch-and-rinse group had better results than the self-indulgent group.
290

Étude en tolérance aux dommages des joints de colle sur les bords d’attaques d’hélicoptères. Cas de défauts sollicités en modes I et II, en statique et fatigue dans différentes conditions environnementales / Damage tolerance analysis of bonded joints on helicopter’s blade leading edge. Study of defaults solicited in mode I & II, in static and fatigue in different environmental conditions

Zambelis, Georges 28 November 2017 (has links)
Cette thèse concerne l'analyse de propagation de dommages dans une structure hybride métal/composite assemblée par collage structural. L'approche choisie est basée sur l'identification expérimentale du taux de restitution d'énergie, G, pour une sollicitation en mode I et II. L'éprouvette de type DCB (Double Cantilever Beam), qui a d’abord été adaptée pour être représentative de la structure hybride, permet de construire la R-Curve (évolution de G en fonction de la longueur de fissure, a) et d'étudier la cinétique de propagation de fissure sous sollicitations dynamiques. La même étude a été portée sur l’éprouvette ENF (End Notched Flexure). Une machine d’essais a été créée afin de réaliser les essais quasi-statiques et dynamiques. Un caisson thermique a été conçu pour faire des essais en température et regarder son impact sur les propriétés de la mécanique de rupture des adhésifs. L'originalité de ce travail est le pilotage des essais dynamiques à ΔG imposé, ce qui permet de s'affranchir de la dépendance de G à la longueur du dommage pour le mode I.Les résultats obtenus mettent en évidence les variations des vitesses de propagation (da/dN) à différentes conditions environnementales en mode I et II sur des assemblages composite/métal collés. / This thesis explains the analysis of damage propagation in a metallic/composite hybrid structure, assembled with structural adhesives. The chosen approach is based on the experimental identification of the energies release rates for a solicitation in mode I and II. The DCB (Double Cantilever Beam) specimen, which design was first adapted in order to adequately represent the hybrid structure, allows the construction of the R-Curve (evolution of G versus the crack length, a) and the study of the crack speed propagation under dynamic solicitations. The same study was carried out on the ENF specimen (End Notched Flexure).A testing machine was created in order to perform quasi-static and dynamic tests. A thermal chamber was designed to carry out temperature tests and observe the impact of the latter on the fracture mechanics properties of the adhesives. Performing dynamic tests with an imposed ΔG, which allows one to overcome the dependence of G to the damage length in mode I, is what makes this work original.The obtained results highlight the variation of the speed propagation in different environmental conditions, for mode I and II, on composite/metal bonded assemblies.

Page generated in 0.0497 seconds