Spelling suggestions: "subject:"[een] CELLULOSE SUBSTRATE"" "subject:"[enn] CELLULOSE SUBSTRATE""
1 |
[en] CELLULOSE SUBSTRATE ROOM-TEMPERATURE PHOSPHORIMETRY FOR THE DETERMINATION OF 2 METHYL INDOL E 7 METHYL INDOL: METHOD DEVELOPMENT, VALIDATION AND CRITICAL EVALUATION OF THE APPLICABILITY OF THE TECHNIQUE / [pt] FOSFORIMETRIA EM TEMPERATURA AMBIENTE EM SUBSTRATO DE CELULOSE PARA A DETERMINAÇÃO DE 2 METIL INDOL E 7 METIL INDOL: DESENVOLVIMENTO DE MÉTODO, VALIDAÇÃO E AVALIAÇÃO CRÍTICA DA APLICABILIDADE DA TÉCNICASELMA CUNHA MELLO 05 November 2008 (has links)
[pt] Neste trabalho, a fosforimetria em temperatura ambiente
em
substrato de celulose foi avaliada como técnica analítica
para a determinação de dois derivados do indol (2 metil
indol e 7 metil indol). As características fosforescentes
dos dois analitos foram estudadas de modo univariado em
função de diversos parâmetros experimentais como a taxa
de
decaimento do sinal fosforescente; tipo e quantidade de
sal
de átomo pesado indutor de fosforescência; quantidade
de surfactante modificador de superfície da celulose e
influência da concentração hidrogeniônica da solução de
analito. Uma vez definidos os fatores relevantes,
planejamentos fatoriais do tipo composto central foram
realizados com o intuito de obter superfícies de resposta
que apontassem possíveis interações entre os fatores e
ajudassem na escolha da melhor condição experimental. As
melhores condições para o 2 metil indol foram obtidas com
soluções carreadoras de etanol/água no seu pH original e
em
substratos contendo TlNO3/SDS ou KI. Condições similares
foram obtidas para o 7 metil indol. Para cada uma das
condições selecionadas, foram realizados estudos
para avaliação dos parâmetros de desempenho que
incluíram:
seletividade, linearidade da faixa de trabalho, limite de
detecção, limite de quantificação, exatidão, precisão,
robustez e cálculo de incerteza de medição do sinal
fosforescente em substrato sólido. Em todos os casos
estudados, a resposta analítica apresentou comportamento
linear em função da massa depositada no substrato [R(2) >
0,99]. Os limites de detecção (média dos valores de
branco +
3sb) e de quantificação (média dos valores de branco +
10sb) ficaram na ordem de 10(-5) de mol L(-1) (na ordem
de
dezenas de ng em termos absolutos). A repetitividade do
método apresentou valores entre 15 e 23 % sendo a
principal
componente da incerteza de medição de sinal
fosforescente.
Este valor foi calculado seguindo o procedimento indicado
pelo ISO GUM, ficando entre 22 a 35% (incerteza
combinada)
dependendo da condição experimental e do analito
usado no processo de cálculo. A seletividade foi avaliada
por meio da comparação das características espectrais de
quatro indóis (indol, 2 metil indol, 3 metil indol e 7
metil indol) e entre compostos nitrogenados de diferentes
famílias (quinolina, 7,8 benzoquinolina e acridina). Os
resultados mostraram que não é possível discriminar os
compostos indólicos. Entretanto é possível obter
seletividade para compostos nitrogenados de diferentes
famílias. / [en] In this work, room-temperature phosphorimetry using
cellulose substrates was evaluated as analytical technique
for the determination of two indol derivatives (2 methyl
indol and 7 methyl indol). The phosphorescence from both
analytes were studied in a univaried way in function of
several experimental parameters such as the phosphorescence
decay rate; type and quantity of phosphorescence inducer
(heavy atom salt); amount of surfactant used as
cellulose surface modifier and the influence of the
hidrogenionic concentration of the analyte carrier
solution. Once defined the relevant factors, central
composite designs were performed in order to obtain
response surfaces that pointed out possible interactions
among factors and lead to the best experimental conditions.
For 2 methyl indol, the best conditions were achieved by
using ethanol/water analyte carrier solution at its
original pH, and substrates containing TlNO3/SDS or
KI. Simillar conditions were found for 7 methyl indol. For
each of the selected conditions, studies were performed
aiming to find the analytical figures of merit
which included: selectivity, linearity of the working
range, limit of detection, limit of quantification,
accuracy, precision, robustness and the uncertainty of the
phosphorescence measurement from the solid substrate. In
all cases, the linear response presented a linear behavior
in function of the mass of the analytes placed on the
substrate [R(2) > 0,99]. Limits of detection (blank signals
average + 3sb) and limits of quantification (blank signals
average + 10sb) were in the mol L(-1) range (absolut values
of tenths of ng). The repeatability of the method presented
values between 15 and 23%, being the main components of the
phosphorescence measurement, which were calculated based on
the procedure indicated in the ISO GUM. The uncertainty
value was between 22 and 35% (combined uncertainty)
epending on the experimental condition and on the
analyte used in the calculation process. The selectivity
towards other indols (indol and 7 methyl indol) and other
classes of nitrogenated polycyclic aromatic compounds was
evaluated by comparing phosphorescence characteristics from
these substances. While no discrimination was possible for
the indols, selectivity in the determination of 2 methyl
indol and 7 methyl indol in the presence of acridine, 7,8
benzoquinoline and quinoline) was found.
|
2 |
[pt] DESENVOLVIMENTO E APLICAÇÃO DE MÉTODOS ANALÍTICOS PARA DETERMINAÇÃO DE PICOXISTROBINA E PIRACLOSTROBINA POR CROMATOGRAFIA ELETROCINÉTICA CAPILAR MICELAR E DE ENROFLOXACINA POR FOSFORIMETRIA EM TEMPERATURA AMBIENTE / [en] DEVELOPMENT AND APPLICATION OF ANALYTICAL METHODOS FOR THE DETERMINATION PICOXYSTROBIN AND PYRACLOSTROBIN BY MICELLAR ELECTROKINECTIC CAPILLARY CHROMATOGRAPHY AND ENROFLOXACIN BY ROOM-TEMPERATURE PHOSPHORIMETRYCABRINI FERRAZ DE SOUZA 02 March 2009 (has links)
[pt] No presente trabalho, a cromatografia eletrocinética capilar micelar (MECC) e a fosforimetria em temperatura ambiente em substrato sólido (SSRTP) foram utilizadas como técnicas analíticas para a determinação de duas estrobilurinas (picoxistrobina e piraclostrobina) e de uma fluoroquinolona (enrofloxacina), respectivamente. As condições ótimas de analise por MECC foram determinadas a partir de um estudo univariado dos seguintes parâmetros experimentais e instrumentais: pH do eletrólito de corrida, concentração do tampão, concentração de surfactante (dodecil-sulfato de sódio - SDS), tipo e quantidade de modificador orgânico, temperatura de trabalho e diferença de potencial aplicada. Depois de definidas as condições ótimas (tampão borato 40 mmol L-1, pH igual a 8,5; SDS 30 mmol L-1; acetonitrila 15 por cento em volume, 25 gruas Celsius e 25 kV) foi realizado um estudo para diminuir o limite de detecção (LD) e o limite de quantificação (LQ) do método. Para tal, foi usado o modo de pré-concentração no capilar denominado modo de empilhamento normal (NSM). Nessa abordagem, as soluções de padrões e amostras foram dissolvidas em uma solução de maior impedância (água: borato 40 mmol L-1 pH igual a 8,5 50:50 por cento v/v). Uma cela de caminho óptico alongado também foi utilizada para a tentativa de aumentar a sensibilidade do método. As curvas analíticas foram construídas com o uso de padrão interno (azoxistrobina) e apresentaram comportamento linear e homocedástico com valores de R2 próximos a 0,999. Com o modo NSM, os valores de LD (xb mais 3sb) e de LQ (xb mais 10sb) para a picoxistrobina e para a piraclostrobina ficaram na ordem de 10-7 mol L-1. A precisão do método (repetitividade e reprodutibilidade interna) apresentaram valores entre 5 e 8 por cento para tempo de migração e área dos picos. O método foi aplicado na análise de urina e água de riacho, ambas fortificadas com as estrobilurinas. As amostras de urina foram previamente passadas em coluna de extração em fase sólida (C-18).
As recuperações obtidas para a piraclostrobina foram 75 mais ou menos 4 por cento para as amostras de urina e 94 ou menos 10 por cento para as amostras de água de riacho. Para a picoxistrobina os valores de recuperação foram de 109 mais ou menos 9 por cento e 102 mais ou menos 9 por cento para as amostras de urina e água do riacho respectivamente. As características fosforescentes da enrofloxacina foram estudadas de modo univariado em função de vários parâmetros experimentais tais como o tipo e quantidade de sal de átomo pesado indutor de fosforescência, presença de surfactante modificador de superfície de celulose, influência de concentração hidrogeniônica na solução do analito e estudo do tempo de exposição ao UV para a formação de fotoproduto de sinal mais estável. As melhores condições para o método fosforescente para enrofloxacina foram obtidas em solução básica (solução acetona: NaOH 0,05
mol L-1 50:50 por cento v/v) irradiada com UV por 30 min e substrato contendo 80 Vg de TlNO3. O método foi aplicado em formulações farmacêuticas contendo enrofloxacina e que são utilizadas na medicina veterinária (solução e comprimidos). Um método com a técnica de cromatografia líquida de alta eficiência (HPLC) adaptado da literatura foi utilizado para análise das amostras de enrofloxacina, sendo os resultados comparáveis àqueles obtidos por SSRTP. A curva analítica apresentou resposta linear e homoscedástica na faixa de trabalho escolhida com R2 maior que 0,99. Os valores de LD (xb mais 3sb) e de LQ (xb mais 10sb) foram respectivamente 2,1 and 4,8 ng respectivamente. A precisão (repetitividade e reprodutibilidade interna com troca de analista) do método apresentaram valores entre 2 e 19 por cento. A incerteza de medição do sinal fosforescente foi calculada usando o método sistemático indicado no ISO GUM e valores entre 18 e 26 por cento foram alcançados, com valores de repetitividade com troca de substrato a fonte mais importante de incerteza. No procedimento de validação, os valores de concentração de enrofloxacina encontrados nas amostras de medicamento analisadas por SSRTP e por HPLC foram estatisticamente semelhantes (valor de texperimental iguais a 0,48 e 1,04 sendo menor que o valor de tcrítico igual a 2,23). / [en] In the present work, micellar electrokinectic capillary
chromatography
(MECC) and solid surface room-temperature phosphorimetry
(SSRTP) were used
as analytical techniques for the determination of two
strobilurins (picoxystrobin
and pyraclostrobin) and of one fluoroquinolones
(enrofloxacin), respectively. The
experimental conditions for MECC have been optimized using
an univariate
approach for the following experimental and instrumental
parameters: pH of the
working electrolyte, concentration of the buffer,
concentration of surfactant
(sodium dodecyl-sulphate - SDS), type and amount of organic
modifier, working
temperature and applied potential. After defined the best
conditions (borate buffer
40 mmol L(-1) pH=8.5; 30 SDS mmol L(-1); acetonitrile 15%
in volume, 25 ºC and 25
kV), a study was carried through to improve the limit of
detention (LD) and the
limit of quantification (LQ) of the method. In order to do
that, an on-line analyte
pre-concentration called normal stacking mode (NSM) was
used. In such
approach, the standards and samples have been dissolved in
a solution of higher
impedance (water: borate 40 mmol L(-1) pH=8.5 50:50% v/v).
A high sensitivity
detection cell also was used to attempt the increasing of
the sensitivity of the
method. The analytical curves have been constructed with
the use of an internal
standard (azoxystrobin) and a linear response and
homocedastic behavior were
observed with R2 values of at least 0.999. The NSM mode
allowed the values of
LD (x(b) + 3(sb)) and of LQ (x(b) + 10(sb)) in the order of
10(-7) mol L(-1) for picoxystrobina
and pyraclostrobina. The precision of the method
(repeatability and intermediate
precision) was characterized by values between 5 and 8%.
The method was
applied in the analysis urine and stream water, both type
of samples fortified with
the strobilurins. The urine sample was previously passed
through a solid phase
extraction column (C-18). The recoveries achieved for
pyraclostrobina were 75 Â +-
4% for urine and 94 Â +- 10% for stream water samples. For
picoxystrobin, the
recovery values were 109 Â +- 9% and 102 Â +- 9% respectively for
urine and stream
water samples. The phosphorimetric characteristics of
enrofloxacin have been
studied in an unvaried way for experimental parameters such
as the type and
quantity of phosphorescence inducer (heavy atom salt),
surfactant used as cellulose surface modifier, influence of
the hidrogenionic concentration in the
analyte solution and study of the UV exposition time for
the formation of a more
signal stable photoproduct. The best conditions for the
phosphorimetric method
for enrofloxacin were the use of basic solution (solution
acetone: NaOH 0.05 mol
L-1 50:50% v/v) irradiated with UV for 30 min and cellulose
substrates containing
80 Vg of TlNO3. The method was applied in pharmaceutical
formulations
containing enrofloxacin employed in veterinary medicine
(solution and pills). A
method based on high efficiency liquid chromatography
(HPLC), adapted from
literature, was used as a reference method and the the
results obtained for
enrofloxacin was comparable to the ones achieved by SSRTP.
The analytical
curve presented linear and homocedastic behavior with R2
values higher than
0.99. The LD (x(b) + 3(sb)) and the LQ (x(b) + 10(sb))
values were 2.1 and 4.8 ng
respectively. The precision (repeatability and intermediate
precision with change
of analyst) of the method presented values between 2 and
19%. The uncertainty
of the phosphorescence measurement was calculated using the
systematic
method indicated in the ISO GUM. Values between 18 and 26%
had been
achieved, with the repeatability with substrate change the
most important source
uncertainty. In the validation procedure, enrofloxacin
concentration values found
in the medicine samples analyzed by SSRTP and HPLC were
statistically similar
( t(experimental) value of 0.48 and 1.04 smaller than the
t(critic) value of 2.23).
|
3 |
[en] SOLID SURFACE ROOMTEMPERATURE PHOSPHORIMETRY FOR THE SELETIVE DETERMINATION OF NITROGENATED AND SULPHURATED POLYCICLIC AROMATIC COMPOUNDS INGASOLINE AND SEDIMENT SAMPLE / [pt] UTILIZAÇÃO DA FOSFORIMETRIA NA TEMPERATURA AMBIENTE SUPORTADA EM SUBSTRATO SÓLIDO PARA A DETERMINAÇÃO SELETIVA DE COMPOSTOS POLICÍCLICOS AROMÁTICOS NITROGENADOS E SULFURADOS EM GASOLINA E EM SEDIMENTOCARLOS EDUARDO CARDOSO 27 June 2007 (has links)
[pt] Neste trabalho, métodos analíticos baseados na
fosforimetria na
temperatura ambiente foram desenvolvidos para a
determinação de sete
compostos policíclicos aromáticos (CPA) sulfurados e
nitrogenados presentes do
petróleo. Mais especificamente, o objetivo foi o de
fornecer ferramentas
analíticas que permitissem avaliar e quantificar estes CPA
em gasolina e em
uma amostra ambiental (sedimento). Adicionalmente, a
informação obtida
através da fosforimetria mostrou potencial para permitir
diferenciar amostras (por
exemplo, a identificação de amostras contaminadas) por
meio de perfil em três
dimensões ou curvas de nível. A aplicação de técnica de
varredura sincronizada
e o uso do efeito externo seletivo do átomo pesado
aumentaram o grau de
seletividade e de discriminação entre amostras, pois
induziu fosforescência de
componentes específicos na amostra e melhorou a resolução
espectral dos
resultados. Inicialmente, foi feito um estudo das
características fosforescentes
das substâncias em diferentes condições experimentais,
seguido da
maximização do sinal fosforescente de cada uma das
substâncias nas condições
experimentais mais propícias para observação do sinal
fosforescente. Para tal, o
papel filtro, previamente tratado para redução do sinal de
fundo, foi utilizado
como substrato sólido para imobilização dos analitos,
permitindo a observação
de intensa fosforescência na temperatura ambiente. Os
parâmetros de mérito
das metodologias desenvolvidas para cada um dos analitos
em questão foram
obtidos. As faixas lineares se estenderam entre 1,0 x 10-7
e 5,0 x 10-4 mol L-1,
considerando as concentrações das soluções dos analitos
aplicadas no
substrato. Os coeficientes de determinação (r2) obtidos
ficaram sempre acima de
0,9784. Os limites de detecção absolutos (para 5 µL de
amostra) foram todos na
ordem do ng, mostrando a capacidade para detecção sensível
em termos de
massa efetiva de analito. Os testes de repetibilidade
mostraram valores variando
entre 12 e 18%, o que pode ser considerado satisfatório
para a técnica realizada
em substrato sólido. Também foram conduzidos estudos de
robustez e
reprodutibilidade. Alternativamente, sinais fosforescentes
foram maximizados em
condições experimentais secundárias do ponto de vista da
magnitude de sinal, mas potencialmente relevantes do ponto
de vista da seletividade. Testes de
recuperação indicaram, na maioria dos casos, resultados
bastante satisfatórios
no caso das misturas sintéticas contendo quantidades
eqüimolares de
componentes (nesse caso, foram testadas várias combinações
de analitos e de
interferentes) ou contendo interferentes, em concentrações
cinco vezes maior
que a do analito de interesse. Nos casos mais críticos em
termos de
interferências, recursos instrumentais ou quimiométricos
foram aplicados para
melhorar a seletividade e possibilitar a quantificação. Os
métodos desenvolvidos
foram testados em amostras simuladas de gasolina, em
gasolina comercial e em
uma matriz ambiental (sedimento) fortificadas com os
analitos de interesse. As
recuperações obtidas foram bastante satisfatórias e
compreendidas entre 90% e
117%. Estudos envolvendo varreduras de fosforescência
total (TPS) também
foram realizados, com o intuito de se obter uma impressão
digital característica
para cada um dos analitos. Testes de TPS em gasolina
comercial indicaram a
presença de pelo menos seis dos sete analitos estudados,
devido à obtenção de
perfis espectrais muito semelhantes aos dos padrões.
Testes adicionais
mostraram a capacidade de identificar contaminações
(misturas) na gasolina
pela adição de diesel e de querosene. / [en] In this work, analytical methods based on room-temperature
phosphorimetry were developed aiming the quantification of
seven polycyclic
aromatic compounds (PAC) containing sulfur and nitrogen
present in petroleum.
More specifically, the goal was to obtain analytical tool
to allow the evaluation
and the quantification of these PCA in sediment and
gasoline. In addition, the
phosphorimetric information displayed potential for the
discrimination of samples
(for instance, the identification of contaminated samples)
by means of three
dimension plots or level curves. The application of
synchronized sweeping
technique and the use of the selective external heavy atom
effect had increased
the degree of selectivity and discrimination between
samples, since it induces
phosphorescence from specific components of the sample and
improved the
spectral resolution of the results. Initially, a study of
the phosphorescent
characteristics of the compounds in different experimental
conditions was made,
followed of the signal maximization in the most
appropriate experimental
conditions for the observation of phosphorescence. Filter
paper, previously
treated for background reduction, was employed as solid
substrate for the
immobilization of analytes. The analytical figures of
merit for each one of the
methods had been obtained. The linear range varied between
1,0 x 10-7 mol L-1
and 5,0 x 10-4 mol L-1, taking into consideration the
concentration of the solutions
spotted on the substrate. The determination coefficient
values (r2) were always
above of 0.9784. The absolute limits of detection (5 µL
sample) were in ng order,
showing the sensitivity of the developed methods. The
repeatability tests had
enabled values varying between 12 and 18%, which can be
considered
satisfactory for solid substrate technique. Robustness and
reproducibility studies
were also carried out. Additionally, secondary
experimental conditions, in terms
of signal magnitude, were optimized since these could be
relevant from the
selective point of view. Recovery tests indicated, in most
of the cases,
satisfactory results for synthetic mixtures containing
equimolar quantities of
components (in these cases, several analyte/interferent
combinations were tested) and containing interferents in
concentrations five times higher than the
one of the analytes. In the most critical cases in terms
of interferences,
instrumental or quimiometric approaches had been applied
to improve selectivity
and make the quantification possible. The developed
methods had been tested in
simulated gasoline samples, commercial gasoline and in a
sediment sample
fortified with the analytes of interest. The obtained
recoveries had been
considered satisfactory and within 90 and 117%. Total
phosphorescence
scanning (TPS) studies had been also carried out in order
to get the
characteristic fingerprint for each one of the compounds
of interest. TPS tests in
gasoline had indicated the presence of six out of seven of
the studied analytes,
since very similar fingerprints were obtained. Additional
tests had demonstrated
the capability of this procedure to detect gasoline
contaminations with diesel or
kerosene.
|
4 |
[en] SOLID SURFACE ROOM-TEMPERATURE PHOSPHORIMETRY (SSRTP) FOR THE DETERMINATION OF TWO BETA-CARBOLINES DERIVATIVES (HARMANE E HARMINE) / [pt] FOSFORIMETRIA NA TEMPERATURA AMBIENTE E EM SUBSTRATO SÓLIDO (FTASS) PARA A DETERMINAÇÃO DE DOIS DERIVADOS DA BETA-CARBOLINA (HARMANE E HARMINE)FLAVIA FERREIRA DE CARVALHO MARQUES 01 August 2005 (has links)
[pt] Neste trabalho foi avaliado o uso da Fosforimetria na
Temperatura
Ambiente em Substrato Sólido (FTASS) como técnica analítica
aplicável na
determinação de dois derivados da β-carbolina (harmane e
harmine). Como
suporte sólido foi utilizado o papel de filtro de baixo
sinal de fundo. As
características fosforescentes dos analitos foram estudadas
em função de
diversos parâmetros experimentais, que foram posteriormente
otimizados
visando a maximização do sinal fosforescente. Estes
parâmetros foram: efeito de
íons de átomos pesados; uso de surfactante como modificador
de superfície; pH
e volume de tampão; sistema de solventes e irradiação
prévia das β-carbolinas
com UV. As melhores situações para ambos os analitos foram
obtidas em pH
natural com a adição de Tl+ e em pH básico na presença de
Ag+. Após a
otimização das condições experimentais relevantes, os
parâmetros analíticos de
mérito foram obtidos. Para o harmane, faixas lineares
dinâmicas (a partir do
limite de quantificação, LQ) de 0,39 - 456 ng (Ag+/pH=12) e
de 8,10 - 911 ng
(Tl+/pH=7,7) foram obtidas. Para o harmine, a faixa linear
dinâmica, partindo do
LQ, foi de 0,59 - 1244 ng (dividido em duas faixas
distintas) quando Ag+/pH=9 foi
empregado. Com o uso de Tl+/pH=5,1, a faixa obtida foi de
0,53 a 249 ng. A
precisão do método para as duas substâncias ficou dentro do
esperado para
esta técnica. Também foi estudado o potencial interferente
de algumas
substâncias (AZT, talidomida e outros) e da matriz urina. O
desempenho do
método foi testado através de testes de recuperação em
formulações
farmacêuticas simuladas e em urina enriquecida com o(s)
analito(s), sendo as
recuperações encontradas dentro da faixa recomendada de 90
a 110 %. Estudos
envolvendo a determinação seletiva em misturas contendo
ambos os derivados
da β-carbolina mostraram a viabilidade da determinação
seletiva de harmine na
presença de harmane usando apenas um ajuste de pH. / [en] In the present work a Solid Surface Room-Temperature
Phosphorimetry
(SSRTP) based analytical method was developed aiming the
determination of
two â-carbolines derivatives (harmane and harmine). A low
background filter
paper was employed as solid support. The phosforimetric
characteristics of the
analytes were studied as function of several parameter,
afterwards optimized
aiming the maximization of phosphorescence. Among the
studied parameters
were the effect of heavy atom ions; the use of surfactants
as substrate surface
modifier; pH and volume of buffer; solvent system and the
previuos UV irradiation
of the analytes. The best results for both analytes were
achieved using Tl+ in
natural pH and using Ag+ in basic pH. After optimization of
the relevant
experimental conditions, the analytical figures of merit
were obtained. For
harmane, linear dynamic ranges (starting from the limit of
quantification, LQ) from
0.39 to 456 ng (Ag+/pH=12) and from 8.10 to 911 ng
(Tl+/pH=7.7) were achieved.
For harmine, the linear dynamic ranges, stating from LQ,
were from 0.59 to 1244
ng (divided in two linear ranges) when Ag+/pH=9 was used.
When Tl+/pH=5.1
was employed, linear ranges were from 0.53 to 249 ng. The
precision of the
method was in accordance with the values expected for this
technique. The
potential interferent effect of some substances (AZT,
thalidomide and others) as
well as the effect of urine matrix were also studied. The
performance of the
method was evaluated by recovery tests using simulated
pharmaceutical
formulations and analyte spiked urine samples. In both
cases, recoveries within
the recomended range (from 90 to 110 %) were achieved.
Studies involving the
selective determination of â-carbolines derivatives have
indicated that the
determination of harmine in the presence of harmane is
feasable only by a simple
sample pH adjustment.
|
Page generated in 0.0451 seconds