• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 75
  • 73
  • 14
  • 10
  • 3
  • 3
  • 3
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 225
  • 225
  • 89
  • 82
  • 72
  • 41
  • 40
  • 39
  • 37
  • 37
  • 34
  • 30
  • 26
  • 25
  • 25
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
191

Um novo sistema de refrigeração com controle de temperatura, compressor aberto, máquina de indução trifásica com velocidade variável e correção ativa do fator de potência do estágio de entrada

Leandro, Eduardo [UNESP] 25 September 2006 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:22:35Z (GMT). No. of bitstreams: 0 Previous issue date: 2006-09-25Bitstream added on 2014-06-13T19:26:47Z : No. of bitstreams: 1 leandro_e_me_ilha.pdf: 1745578 bytes, checksum: 2db70f1465f9f7258fdbcda3cdebf72c (MD5) / Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / Este trabalho apresenta uma nova proposta para sistema de refrigeração com controle dinâmico de temperatura, operando com estrutura de compressor aberto, acionado por motor de indução trifásico com velocidade variável, e estágio de entrada retificador com correção ativa do fator de potência. O estágio de entrada é composto por um retificador Boost monofásico com elevado fator de potência, com duas células entrelaçadas, operando no modo de condução crítica, empregando técnica de comutação não dissipativa e controlado por dispositivo FPGA, associado a um estágio de saída inversor de dois níveis convencional trifásico à IGBT, o qual é controlado por um Processador Digital de Sinais (DSP - Digital Signal Processor). A técnica de comutação não dissipativa para o estágio de entrada é baseada em células ZCS (Zero-current-switching). As principais características do retificador incluem a redução da ondulação da corrente de entrada, redução da ondulação da tensão de saída retificada, utilização de componentes com reduzidos esforços, reduzido volume do filtro de entrada para Interferências Eletromagnéticas (EMI - Electromagnetic Interference), elevado Fator de Potência (FP) e reduzida Distorção Harmônica Total (DHT) da corrente de entrada, atendendo os limites da norma IEC61000-3-2. O controle digital para o estágio de saída inversor foi desenvolvido usando duas diferentes técnicas, incluindo a técnica convencional controle escalar Volts/Hertz (V/Hz) e o controle Vetorial com Orientação pelo Fluxo do estator, com o propósito de verificar a aplicabilidade e a performance dos controles digitais propostos, para o controle contínuo da temperatura, aplicados a um protótipo de sistema de refrigeração. / This work presents a new proposal for refrigeration systems with dynamic control of temperature, working with structure of open compressor, driving a three-phase induction motor with variable speed, and input rectifier with active power factor correction. The proposed system is composed of a single-phase high-power-factor boost rectifier, with two cells in interleaved connection, operating in critical conduction mode, and employing a softswitching technique, controlled by a Field Programmable Gate Array (FPGA), associated with a conventional three-phase IGBT bridge inverter (VSI - Voltage Source Inverter), controlled by a Digital Signal Processor (DSP). The soft-switching technique for the input stage is based on zero-current-switching (ZCS) cells. The rectifier s features include reduction in input current ripple, reduction in output voltage ripple, use of low stress devices, low volume for the EMI input filter, high input power factor (PF), and low total harmonic distortion (THD) in the input current, in compliance with the IEC61000-3-2 standards. The digital controller for the output stage inverter has been developed using two different techniques, the conventional Voltage-Frequency control (scalar V/Hz control), and a simplified stator oriented vector control, in order to verify the feasibility and performance of the proposed digital controls, for continuous temperature control, applied at a refrigerator prototype.
192

Condicionador unificado de qualidade de energia com controle digital / Unified power quality conditioner with digital control

Dias, Josué 11 December 2009 (has links)
Made available in DSpace on 2016-12-12T17:38:37Z (GMT). No. of bitstreams: 1 RESUMO - Josue.pdf: 8954 bytes, checksum: 37d4018bcbba745d53a694b1e3fad11b (MD5) Previous issue date: 2009-12-11 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / This work shows a unified power quality conditioner based on a digital controlier. Such conditioner is composed of shunt active power filter, to compensate the input une current, and series active power filters to compensate the load voltage. The proposal consist in applying a simple control strategy based on direct comparison the input une current and load voltãge waveforms with sinusoidal references. Initially is presented a study about the active power conditioner characteristics, classification and topologies, foliowing UPQC power structure is explored, as converter definition, aspects for grid connection and analysis and project at passive filters. Afterwards, the mathematicál models are derived, the controllers are defined and simulations are performed. Finaily, the results obtained with UPQC practical tests are shown. / Este trabalho apresenta um condicionador unificado de qualidade de energia (UPQC) controlado digitalmente. Tal condicionador é composto por um filtro ativo paralelo, para compensar a corrente na rede, e um filtro ativo série, para compensara tensão na carga. A proposta consiste em aplicar uma estratégia de controle simples baseada na comparação direta da corrente na rede e tensão na carga com referências senoidas. Inicialmente é apresentado um estudo a respeito das topologias e classificação dos condicionadores de energia, em seguida é explorada a estrutura de potência do UFQC, como definição do conversor, aspectos relacionados à conexão com a rede e anAlise e projeto dos filtros passivos. Posteriormente são obtidos os modelos matemáticos, projetados os controladores e elaboradas simulações para, finalmente apresentar os resultados obtidos com os ensaios do UPQC.
193

Sistema de controle digital com rápida resposta transitória para um retificador monofásico meia-ponte / Digital control system for a single-phase half-bridge rectifier with fast dynamic response

Nodari, Luís Mariano 30 May 2011 (has links)
Made available in DSpace on 2016-12-12T17:38:37Z (GMT). No. of bitstreams: 1 Luis Mariano Nodari.pdf: 2083674 bytes, checksum: f3c4bf3291e2d0a7c63bb7bea7118f85 (MD5) Previous issue date: 2011-05-30 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / This work proposes a digital control system for a half-bridge boost rectifier, which composes the input stage of a single-phase transformerless double-conversion UPS. The proposed control system has an inner current loop and two outer voltage loops to maintain near unity input power factor and to regulate the dc bus voltages. The control loops operate with distinct sampling frequencies, so that current loop operates with high sampling frequency, and voltage loops operate with reduced sampling frequency and moving average filters to improve the dynamic response, without affecting the input power factor. Simulation and experimental results are included to demonstrate the performance of the closed-loop system even under severe load conditions. / Esta Dissertação de Mestrado propõe um sistema de controle digital para um retificador meiaponte monofásico, que integra o estágio de entrada de uma UPS não isolada de dupla conversão monofásica. O sistema de controle proposto tem uma malha de corrente interna e duas malhas de tensão externas para manter o fator de potência unitário e regular a tensão no barramento. O controle opera com frequências distintas de amostragem, sendo que a malha de corrente opera com alta frequência de amostragem, enquanto as malhas de tensão operam com baixas frequências e com filtros de média móvel para melhorar a resposta dinâmica das tensões de saída do retificador, sem afetar o fator de potência de entrada. Resultados de simulação e experimentais demonstram o bom desempenho do sistema de controle digital proposto mesmo em condições severas de carga.
194

Controle discreto com modos deslizantes em sistemas incertos com atraso no sinal de controle /

Ribeiro, Jean Marcos de Souza. January 2006 (has links)
Orientador: José Paulo Fernandes Garcia / Banca: Marcelo Carvalho M. Teixeira / Banca: Edvaldo Assunção / Banca: Fuad Kassab Junior / Banca: Marco Henrique Terra / Resumo: Este trabalho apresenta três novas estratégias de controle discreto. O enfoque principal do trabalho foi dado ao Controle Discreto com Modos Deslizantes (CDMD) aplicados em sistemas que possuem atraso no processamento do sinal de controle. As novas estratégias de controle objetivam a elaboração de leis de fácil implementação prática e que ao mesmo tempo sejam robustas a incertezas da planta. Uma característica destas novas abordagens para controle discreto com atraso no tempo é a utilização de um Controle com Modos Deslizantes sem a necessidade de predição do sinal de controle. Os métodos de projeto propostos podem ser aplicados no controle de plantas estáveis ou instáveis com atraso no sinal de controle. Uma das estratégias foi elaborada para realizar controle apenas em sistemas discretos que não possuem atraso no sinal de controle, enquanto que as demais são utilizadas para controle em sistemas com atraso. São apresentadas simulações e resultados de implementações práticas, sobre uma planta estável de Controle Automático da Geração (CAG) e sobre um Sistema Pêndulo Invertido, que caracteriza bem uma planta instável. Os resultados comprovam a eficácia dos novos controladores. / Abstract: This work presents three new strategies of discrete-time control. The main focus of the work was given to the Sliding Mode Control (SMC) applied in systems that present delay in the processing of the control sign. The new control strategies provide laws of control of easy practical implementation and that at the same time are robust to uncertainties of the plant. A characteristic of these new approaches, for discrete-time control with delay-time, is the use of a Sliding Mode Control without the need of prediction of the control signal. The proposed design methods can be applied in the control of stable or unstable plants, with delay in the control signal. One of the strategies was elaborated to accomplish control just in discrete-time system without delay-time in the control sign, while the others are used for control in systems with delay-time. Simulations and experimental results are shown on a stable plant of Automatic Generation Control (AGC) and on Inverted Pendulum System, that is an unstable plant. The results prove the controllers' effectiveness. / Doutor
195

Projeto e implementação de método para conexão paralela de UPSs com compartilhamento de potência

Annunziato, Rafael Christiano 31 August 2012 (has links)
Este trabalho apresenta o projeto e a implementação prática de um método completo para ser utilizado na conexão de UPSs monofásicos em paralelo. Existe um algoritmo que executa o droop de fase/frequência, e um novo método que trabalha com e sem comunicação de dados entre os inversores. Quando a comunicação está ativa, um novo algoritmo é utilizado, inserindo um resistência virtual variável, junto com o compartilhamento de potência ativa, obtendo um baixo valor de THD (Total Harmonic Distortion) na tensão de saída e bom compartilhamento de potência. Quando a comunicação de dados não funciona, uma resistência virtual constante é inserida, aumentando a THD de saída com carga não-linear, mas ainda proporcionando um bom compartilhamento de potência ativa. A vantagem é poder obter um bom desempenho quando a comunicação de dados está operando, mas, no caso de sua falha, o sistema ainda funciona, proporcionando maior confiabilidade. A implementação possui um algoritmo de emulação de carga eletrônica, com o propósito de executar testes de produção, baseado no mesmo algoritmo de paralelismo, apenas mudando algumas variáveis. / This work presents the design and experimental implementation of a complete paralleling method to be used for parallel single-phase UPSs connection. There is a algorithm that performs a phase/frequency droop, and a new method to work with or without data communication among the inverters. When communication is working, a new algorithm is used, inserting a variable virtual resistance in the output, along with active power sharing, obtaining a low output voltage THD (Total Harmonic Distortion) value and good power sharing. Without communication a constant virtual resistance is inserted, increasing the output THD with non-linear load, but still allowing a good active power sharing. The advantage is to obtain a good performance operation with communication, but, in case of communication failure, the system still works providing more reliability. The implementation have a electronic load emulation algorithm, with purpose to execute factory tests, based in the same parallelism algorithm, just changing some variables.
196

Projeto e implementação de um retificador isolado em alta frequência

Alvarenga, Daniel Bernardo de 25 March 2014 (has links)
NHS / Este trabalho apresenta o desenvolvimento e a implementação de um retificador Ponte Completa isolado em alta frequência com elevado fator de potência para aplicações em UPS. Este conversor é composto por um conversor Boost multi-fase operando em modo contínuo (CCM) integrado a um conversor ZVS CC-CC Ponte Completa sem o indutor de saída operando em modo descontínuo (DCM). A topologia apresenta comutação suave intrínseca, permitindo a operação com baixas perdas por comutação em altas frequência. Este conversor também apresenta operação multi-fase e redução da ondulação da corrente de entrada com o uso de dois indutores de entrada. A estrutura sem ponte de diodos possibilita a redução do número de componentes da etapa de potência, apresentando baixas perdas por condução. A implementação de uma nova malha de controle de potência, adicional ao controle convencional, permite melhor resposta dinâmica do conversor. Os detalhes da estratégia de controle, bem como o projeto dos componentes do circuito são apresentados. Os resultados são obtidos através de um protótipo com frequência de chaveamento de 43,2 kHz e comprovados através da simulação, sendo o rendimento máximo é igual a 92,2 % com potência nominal, 1,7 kW. Um novo controle com duas modulações independentes também é proposto, permitindo o conversor também operar como abaixador de tensão. Esta modificação possibilita maior faixa de tensão de saída do conversor e consequentemente para a saída do UPS. / This paper presents the development and implementation of a high power factor full-bridge rectifier with high frequency isolation for UPS applications. This converter is composed by a multiphase boost converter operating in continuous mode (CCM) integrated with a ZVS DC-DC full-bridge converter without the output inductor and operating in discontinuous mode (DCM). The topology presents intrinsic ZVS commutation allowing the operation with lower switching losses at higher frequencies. It also presents multiphase operation and input current ripple reduction by using two input inductors. The structure bridgeless rectifier reduces the number of semiconductors in conduction of power circuit, presenting lower conduction losses. The implementation of a new power loop control, allows a better dynamic converter response. Details of the control strategy and circuits components design are presented. The results are verified through a prototype with switching frequency equal to 43,2 kHz and the maximum efficiency is equal to 92,2 % at nominal power, 1,7 kW. A new control with two independent modulations is also proposed, allowing the converter operating also as step-down voltage. This modification provides greater range of converter output voltage and thus the output of the UPS.
197

Controlador de demanda e emulador do consumidor residencial para manutenção do conforto do usuário em Smart Grids

Maciel, Savio Alencar 20 October 2014 (has links)
Neste trabalho é apresentada uma abordagem de controle de demanda para consumidores residenciais de baixa tensão, visando melhoria da eficiência energética em Smart Grids. Inicialmente, um emulador de cargas elétricas residenciais é modelado com base na literatura. O emulador é composto pelo modelo de um reservatório de aquecimento de água (boiler), o modelo de um aparelho de ar condicionado e também modelos de consumo de iluminação, televisores e uma geladeira. Utilizando o software Matlab foi realizada a implementação e simulação do emulador. Os principais algoritmos de controle de demanda são investigados, a fim de verificar o seu desempenho quando aplicados ao conjunto de cargas residenciais. Esses algoritmos normalmente realizam o controle de demanda a partir de um sistema de prioridades. Ainda, a partir dessa analise demostra-se que estes algoritmos consideram níveis de conforto do usuário, porém não permitem o acionamento de duas ou mais cargas em um mesmo período caso a demanda da residência ultrapasse um limite predeterminado. Portanto, propõem-se um algoritmo de controle de demanda adaptativo que utiliza o método de busca Rosenbrock, com o objetivo de sobrepujar tais limitações. O procedimento proposto realiza a operação das cargas residenciais de forma gradual considerando níveis de prioridade e parâmetros de conforto dos usuários. Demonstra-se através de simulações e experimentos que através do método proposto é possível realizar a ativação de diversas cargas concorrentemente, desde que respeitados os níveis de conforto e de demanda. Para obtenção dos resultados experimentais o controlador de demanda foi implementado em um sistema embarcado e testado com o emulador de cargas elétricas residenciais implementado em uma arquitetura HIL (Hardware-in-the-loop). Analisando os resultados, observou-se que o consumo de energia foi o mesmo para todos os cenários simulados sendo que a demanda se manteve abaixo dos limites parametrizados. Porém com o limitador de demanda ativo, se obteve uma redução de até 52% no tempo de aquecimento da água utilizando o controlador de demanda adaptativo, dessa forma o desconforto dos usuários pode ser minimizado. / This work presents an approach to control demand for residential low voltage consumers, aiming to improve energy efficiency in Smart Grids. Initially, an emulator of residential electric loads is modeled based on the literature. The emulator consists of a reservoir for water heating model, the model of an air conditioner and also models of consumption for lighting, televisions and a refrigerator. The implementation and simulation were performed using software Matlab. The demand control algorithms are investigated in order to verify its performance when applied to the set of residential loads. These algorithms typically perform control demand from a system of priorities. Still, from this analysis it demonstrates that these algorithms consider levels of user comfort, but do not allow the drive of two or more loads in the same period of residence if the demand exceeds the limit. Therefore, we propose a control algorithm that uses Rosenbrock search of demand adaptive method, aiming to overcome these limitations. The proposed procedure performs the operation of residential loads gradually considering priority levels and parameters of comfort of users. It is shown through simulations and experiments using the proposed method can perform the activation of several concurrently loads, provided they comply with the limits of comfort and demand. To obtain the experimental results demand the controller was implemented in an embedded system and tested with the emulator residential electrical loads implemented in a HIL (Hardware-in-theloop) architecture. Analyzing the results, it was observed that the power consumption is the same for all scenarios simulated and demand remained below parametric limits. But with the demand limiter active, we obtained a reduction of up to 52% in heat water using the demand controller adaptive, so the discomfort of the users can be minimized.
198

Projeto e implementação de método para conexão paralela de UPSs com compartilhamento de potência

Annunziato, Rafael Christiano 31 August 2012 (has links)
Este trabalho apresenta o projeto e a implementação prática de um método completo para ser utilizado na conexão de UPSs monofásicos em paralelo. Existe um algoritmo que executa o droop de fase/frequência, e um novo método que trabalha com e sem comunicação de dados entre os inversores. Quando a comunicação está ativa, um novo algoritmo é utilizado, inserindo um resistência virtual variável, junto com o compartilhamento de potência ativa, obtendo um baixo valor de THD (Total Harmonic Distortion) na tensão de saída e bom compartilhamento de potência. Quando a comunicação de dados não funciona, uma resistência virtual constante é inserida, aumentando a THD de saída com carga não-linear, mas ainda proporcionando um bom compartilhamento de potência ativa. A vantagem é poder obter um bom desempenho quando a comunicação de dados está operando, mas, no caso de sua falha, o sistema ainda funciona, proporcionando maior confiabilidade. A implementação possui um algoritmo de emulação de carga eletrônica, com o propósito de executar testes de produção, baseado no mesmo algoritmo de paralelismo, apenas mudando algumas variáveis. / This work presents the design and experimental implementation of a complete paralleling method to be used for parallel single-phase UPSs connection. There is a algorithm that performs a phase/frequency droop, and a new method to work with or without data communication among the inverters. When communication is working, a new algorithm is used, inserting a variable virtual resistance in the output, along with active power sharing, obtaining a low output voltage THD (Total Harmonic Distortion) value and good power sharing. Without communication a constant virtual resistance is inserted, increasing the output THD with non-linear load, but still allowing a good active power sharing. The advantage is to obtain a good performance operation with communication, but, in case of communication failure, the system still works providing more reliability. The implementation have a electronic load emulation algorithm, with purpose to execute factory tests, based in the same parallelism algorithm, just changing some variables.
199

Projeto e implementação de um retificador isolado em alta frequência

Alvarenga, Daniel Bernardo de 25 March 2014 (has links)
NHS / Este trabalho apresenta o desenvolvimento e a implementação de um retificador Ponte Completa isolado em alta frequência com elevado fator de potência para aplicações em UPS. Este conversor é composto por um conversor Boost multi-fase operando em modo contínuo (CCM) integrado a um conversor ZVS CC-CC Ponte Completa sem o indutor de saída operando em modo descontínuo (DCM). A topologia apresenta comutação suave intrínseca, permitindo a operação com baixas perdas por comutação em altas frequência. Este conversor também apresenta operação multi-fase e redução da ondulação da corrente de entrada com o uso de dois indutores de entrada. A estrutura sem ponte de diodos possibilita a redução do número de componentes da etapa de potência, apresentando baixas perdas por condução. A implementação de uma nova malha de controle de potência, adicional ao controle convencional, permite melhor resposta dinâmica do conversor. Os detalhes da estratégia de controle, bem como o projeto dos componentes do circuito são apresentados. Os resultados são obtidos através de um protótipo com frequência de chaveamento de 43,2 kHz e comprovados através da simulação, sendo o rendimento máximo é igual a 92,2 % com potência nominal, 1,7 kW. Um novo controle com duas modulações independentes também é proposto, permitindo o conversor também operar como abaixador de tensão. Esta modificação possibilita maior faixa de tensão de saída do conversor e consequentemente para a saída do UPS. / This paper presents the development and implementation of a high power factor full-bridge rectifier with high frequency isolation for UPS applications. This converter is composed by a multiphase boost converter operating in continuous mode (CCM) integrated with a ZVS DC-DC full-bridge converter without the output inductor and operating in discontinuous mode (DCM). The topology presents intrinsic ZVS commutation allowing the operation with lower switching losses at higher frequencies. It also presents multiphase operation and input current ripple reduction by using two input inductors. The structure bridgeless rectifier reduces the number of semiconductors in conduction of power circuit, presenting lower conduction losses. The implementation of a new power loop control, allows a better dynamic converter response. Details of the control strategy and circuits components design are presented. The results are verified through a prototype with switching frequency equal to 43,2 kHz and the maximum efficiency is equal to 92,2 % at nominal power, 1,7 kW. A new control with two independent modulations is also proposed, allowing the converter operating also as step-down voltage. This modification provides greater range of converter output voltage and thus the output of the UPS.
200

Controlador de demanda e emulador do consumidor residencial para manutenção do conforto do usuário em Smart Grids

Maciel, Savio Alencar 20 October 2014 (has links)
Neste trabalho é apresentada uma abordagem de controle de demanda para consumidores residenciais de baixa tensão, visando melhoria da eficiência energética em Smart Grids. Inicialmente, um emulador de cargas elétricas residenciais é modelado com base na literatura. O emulador é composto pelo modelo de um reservatório de aquecimento de água (boiler), o modelo de um aparelho de ar condicionado e também modelos de consumo de iluminação, televisores e uma geladeira. Utilizando o software Matlab foi realizada a implementação e simulação do emulador. Os principais algoritmos de controle de demanda são investigados, a fim de verificar o seu desempenho quando aplicados ao conjunto de cargas residenciais. Esses algoritmos normalmente realizam o controle de demanda a partir de um sistema de prioridades. Ainda, a partir dessa analise demostra-se que estes algoritmos consideram níveis de conforto do usuário, porém não permitem o acionamento de duas ou mais cargas em um mesmo período caso a demanda da residência ultrapasse um limite predeterminado. Portanto, propõem-se um algoritmo de controle de demanda adaptativo que utiliza o método de busca Rosenbrock, com o objetivo de sobrepujar tais limitações. O procedimento proposto realiza a operação das cargas residenciais de forma gradual considerando níveis de prioridade e parâmetros de conforto dos usuários. Demonstra-se através de simulações e experimentos que através do método proposto é possível realizar a ativação de diversas cargas concorrentemente, desde que respeitados os níveis de conforto e de demanda. Para obtenção dos resultados experimentais o controlador de demanda foi implementado em um sistema embarcado e testado com o emulador de cargas elétricas residenciais implementado em uma arquitetura HIL (Hardware-in-the-loop). Analisando os resultados, observou-se que o consumo de energia foi o mesmo para todos os cenários simulados sendo que a demanda se manteve abaixo dos limites parametrizados. Porém com o limitador de demanda ativo, se obteve uma redução de até 52% no tempo de aquecimento da água utilizando o controlador de demanda adaptativo, dessa forma o desconforto dos usuários pode ser minimizado. / This work presents an approach to control demand for residential low voltage consumers, aiming to improve energy efficiency in Smart Grids. Initially, an emulator of residential electric loads is modeled based on the literature. The emulator consists of a reservoir for water heating model, the model of an air conditioner and also models of consumption for lighting, televisions and a refrigerator. The implementation and simulation were performed using software Matlab. The demand control algorithms are investigated in order to verify its performance when applied to the set of residential loads. These algorithms typically perform control demand from a system of priorities. Still, from this analysis it demonstrates that these algorithms consider levels of user comfort, but do not allow the drive of two or more loads in the same period of residence if the demand exceeds the limit. Therefore, we propose a control algorithm that uses Rosenbrock search of demand adaptive method, aiming to overcome these limitations. The proposed procedure performs the operation of residential loads gradually considering priority levels and parameters of comfort of users. It is shown through simulations and experiments using the proposed method can perform the activation of several concurrently loads, provided they comply with the limits of comfort and demand. To obtain the experimental results demand the controller was implemented in an embedded system and tested with the emulator residential electrical loads implemented in a HIL (Hardware-in-theloop) architecture. Analyzing the results, it was observed that the power consumption is the same for all scenarios simulated and demand remained below parametric limits. But with the demand limiter active, we obtained a reduction of up to 52% in heat water using the demand controller adaptive, so the discomfort of the users can be minimized.

Page generated in 0.0311 seconds