• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 120
  • 95
  • 27
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 288
  • 288
  • 113
  • 105
  • 83
  • 72
  • 72
  • 64
  • 62
  • 57
  • 57
  • 51
  • 46
  • 38
  • 36
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
251

Desenvolvimento de um software para detecção de erros grosseiros e reconciliação de dados estática e dinâmica de processos químicos e petroquímicos / Development of software for static and dynamic gross error detection and data reconciliation of chemical and petrochemical processes

Barbosa, Agremis Guinho 22 August 2018 (has links)
Orientador: Rubens Maciel Filho / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Engenharia Química / Made available in DSpace on 2018-08-22T08:44:14Z (GMT). No. of bitstreams: 1 Barbosa_AgremisGuinho_D.pdf: 4370227 bytes, checksum: 9fc9a5dfb766e6075fe58104c3c22087 (MD5) Previous issue date: 2008 / Resumo: O principal objetivo deste trabalho foi o desenvolvimento de um software para reconciliação de dados, detecção e identificação de erros grosseiros, estimativa de parâmetros e monitoramento da qualidade da informação em unidades industriais em estado estacionário e dinâmico. O desenvolvimento desse software focalizou atender aos critérios de modularidade, extensibilidade e facilidade de uso. A reconciliação de dados é um procedimento de tratamento de medidas em plantas de processos necessário devido ao fato da inexorável presença de erros aleatórios de pequena magnitude associados aos valores obtidos dos equipamentos de medição. Além dos erros aleatórios, por vezes os dados estão associados a erros de maior magnitude e que constituem uma tendência, ou viés. Erros desta natureza podem ser qualificados e quantificados por técnicas de detecção de erros grosseiros. É importante para aplicação de subrotinas de otimização que os dados sejam confiáveis e livres de erros tanto quanto possível. A tarefa da remoção destes erros através de modelos previamente conhecidos (reconciliação de dados) não é trivial, já sendo estudada no campo da engenharia química nos últimos 40 anos e apresenta uma crescente quantidade de trabalhos publicados. Contudo, uma parte destes trabalhos é voltada para aplicação da reconciliação sobre equipamentos isolados, como tanques, reatores e colunas de destilação, ou pequenos conjuntos destes equipamentos e não são muitos os trabalhos que utilizam dados reais de operação. Isto pode ser atribuído à dimensão do trabalho computacional associado ao grande número de variáveis. O que se propõe neste trabalho é tomar partido da crescente capacidade computacional e das modernas ferramentas de desenvolvimento, provendo uma aplicação na qual seja facilitada a tarefa de descrever sistemas de maior dimensão, para estimar dados de qualidade superior, em tempo hábil, para sistemas de controle e otimização. É importante frisar que a reconciliação de dados e a detecção de erros grosseiros são fundamentais para a confiabilidade de resultados de subrotinas de otimização e controle supervisório e também pode ser utilizada para a reconstrução de estados do processo / Abstract: The main goal of this work was the development of software for data reconciliation, gross errors detection and identification, data reconciliation, parameter estimation, and information quality monitoring in industrial units under steady state and dynamic operation. The development of this software was focused on meeting the criteria of modularity, extensibility, and user friendliness. Data reconciliation is a procedure for measurement data treatment in process plants, which is necessary due the fact of the inexorable presence of random, small magnitude errors associated to the values obtained from measurement devices. In addition to the random errors, sometimes data are associated to major magnitude errors that lead to a trend or bias. Errors of this nature can be qualified and quantified through gross errors detection techniques. It is important for optimization routines that data are reliable and error free as much as possible. The task of removal of these errors using previously known models (data reconciliation) is not trivial, and has been studied for the last 40 years in the field of chemical engineering, showing an increasing amount of published works. However, part of these works is devoted to applying data reconciliation over single equipment, such as tanks, reactors, distillation columns, or small sets of these equipments. Furthermore, not much of this published work relies on real operation data. This can be regarded to the dimension of computational work associated to the great number of variables. This work proposes to take advantage of increasing computational capacity and modern development tools to provide an application in which the task of higher dimension systems description is accomplished with ease in order to produce data estimates of superior quality, in a suitable time frame, to control and optimization systems. It is worthwhile mentioning that data reconciliation and gross error detection are fundamental for reliability of the results from supervisory control and optimization routines, and can be used also to process state reconstruction / Doutorado / Desenvolvimento de Processos Químicos / Doutor em Engenharia Química
252

Algoritmus ochranné funkce pro lokalizaci nesymetrie / The algorithm of protection function for the unsymetries location

Kopáček, Petr January 2020 (has links)
The Master Thesis deals with a proposal of algorithm of a protective function for assymetric faults location in resistance-grounded medium voltage networks with decentralized measurement of instantaneous voltage and current values. The theoretical part describes a single pole fault in the resistance-grounded network including the network analysis using the symmetric component method. Furtherly follows brief reserse of nowadays considered possibilities of faults location in the medium voltage networks. The proposed algorithm which works on the principle of negative sequence changes and change differencies of voltage and current is described by mathematical operations and flowchart, and it is furtherly tested in the PSCAD simulator on the proposed network model. Also the algorithm is tested in the Matlab program using the real data from the local distribution network Pod Palackeho vrchem where the initial pilot implementation is assumed. The last part of the thesis includes also the algorithm sensitivity analysis.
253

Fault Location and Classification for Transmission Line Based on Wavelet Transform

Wang, Qiuhong January 2016 (has links)
With the rapid development of power systems, locating and classifying faults is critical to the continuity and reliability of the transmission system. In this thesis, a traveling-wave based technique for fault location and classification on high voltage and extremely high-voltage transmission lines is proposed. The traveling-wave based protection has the advantage of fast response and not being affected by power swing and CTs saturation. In this thesis, the transient characteristics of single line to ground fault (which can be divided into solid fault and arcing fault) and lightning disturbance are extracted by using Clarke transformation and wavelet transformation. The differences among recorded traveling wave arrival times are used to calculate the fault location, and the wavelet energy at different frequency bands is utilized to distinguish between lightning and different kinds of fault. A criterion is proposed according to the energy ratio. The proposed scheme can identify different faults correctly and quickly. In addition, the influence of busbar capacitance, current transformer and coupling capacitor voltage transformer are considered. The simulation of a transmission system has been made in ATP/EMTP, and the calculations have been made in MATLAB. / Med den snabba utvecklingen av kraftsystem är lokalisering och klassificering av fel avgörande för kontinuiteten och tillförlitligheten hos överföringssystem. I denna avhandling föreslås en vågrörelse-baserad teknik för fellokalisering och klassificering av kraftledningar för högspänning och extremt hög spänning. Vågrörelsebaserat skydd har fördelen av snabb respons och att det inte påverkas av kraft fluktuationer och strömtransformsmättnad. I denna avhandling tas momentana egenskaperna av jord till ledningsfel (vilket kan delas in i stumt jordfel och ljusbågefel) och blixtstörning fram med hjälp av Clarke transformation och wavelet transformation. Skillnaderna mellan de uppmätta vågrörelsernas ankomsttider används för att beräkna fellokalisering och wavelet energin vid olika frekvensband, vilket används för att skilja mellan blixt och olika sorters fel. Ett kriterium föreslås enligt energiförhållandet. Det föreslagna systemet kan identifiera olika sorters fel korrekt och snabbt. Dessutom övervägs påverkan av strömskenans kapacitans, strömtransformator och kopplingskondensatorspänningsomvandlare. Simuleringen av transmissionssystem har gjorts med ATP/EMTP, och beräkningarna är gjorda med MATLAB.
254

Finite element and electrical circuit modelling of faulty induction machines: Study of internal effects and fault detection techniques / Modélisation par éléments finis et par équations de circuits des machines asynchrones en défaut: Etude des effets internes et techniques de détection de défauts

Sprooten, Jonathan 21 September 2007 (has links)
This work is dedicated to faulty induction motors. These motors are often used in industrial applications thanks to their usability and their robustness. However, nowadays optimisation of production becomes so critical that the conceptual reliability of the motor is not sufficient anymore. Motor condition monitoring is expanding to serve maintenance planning and uptime maximisation. Moreover, the use of drive control sensors (namely stator current and voltage) can avoid the installation and maintenance of dedicated sensors for condition monitoring.<p><p>Many authors are working in this field but few approach the diagnosis from a detailed and clear physical understanding of the localised phenomena linked to the faults. Broken bars are known to modulate stator currents but it is shown in this work that it also changes machine saturation level in the neighbourhood of the bar. Furthermore, depending on the voltage level, this change in local saturation affects the amplitude and the phase of the modulation. This is of major importance as most diagnosis techniques use this feature to detect and quantify broken bars. For stator short-circuits, a high current is flowing in the short-circuited coil due to mutual coupling with the other windings and current spikes are flowing in the rotor bars as they pass in front of the short-circuited conductors. In the case of rotor eccentricities, the number of pole-pairs and the connection of these pole-pairs greatly affect the airgap flux density distribution as well as the repartition of the line currents in the different pole-pairs.<p><p>These conclusions are obtained through the use of time-stepping finite element models of the faulty motors. Moreover, circuit models of faulty machines are built based on the conclusions of previously explained fault analysis and on classical Park models. A common mathematical description is used which allows objective comparison of the models for representation of the machine behaviour and computing time.<p><p>The identifiability of the parameters of the models as well as methods for their identification are studied. Focus is set on the representation of the machine behaviour using these parameters more than the precise identification of the parameters. It is shown that some classical parameters can not be uniquely identified using only stator measurements.<p><p>Fault detection and identification using computationally cheap models are compared to advanced detection through motor stator current spectral analysis. This last approach allows faster detection and identification of the fault but leads to incorrect conclusions in low load conditions, in transient situations or in perturbed environments (i.e. fluctuating load torque and unideal supply). Efficient quantification of the fault can be obtained using detection techniques based on the comparison of the process to a model.<p><p>Finally, the work provides guidelines for motor supervision strategies depending on the context of motor utilisation. / Doctorat en Sciences de l'ingénieur / info:eu-repo/semantics/nonPublished
255

Using unsupervised machine learning for fault identification in virtual machines

Schneider, C. January 2015 (has links)
Self-healing systems promise operating cost reductions in large-scale computing environments through the automated detection of, and recovery from, faults. However, at present there appears to be little known empirical evidence comparing the different approaches, or demonstrations that such implementations reduce costs. This thesis compares previous and current self-healing approaches before demonstrating a new, unsupervised approach that combines artificial neural networks with performance tests to perform fault identification in an automated fashion, i.e. the correct and accurate determination of which computer features are associated with a given performance test failure. Several key contributions are made in the course of this research including an analysis of the different types of self-healing approaches based on their contextual use, a baseline for future comparisons between self-healing frameworks that use artificial neural networks, and a successful, automated fault identification in cloud infrastructure, and more specifically virtual machines. This approach uses three established machine learning techniques: Naïve Bayes, Baum-Welch, and Contrastive Divergence Learning. The latter demonstrates minimisation of human-interaction beyond previous implementations by producing a list in decreasing order of likelihood of potential root causes (i.e. fault hypotheses) which brings the state of the art one step closer toward fully self-healing systems. This thesis also examines the impact of that different types of faults have on their respective identification. This helps to understand the validity of the data being presented, and how the field is progressing, whilst examining the differences in impact to identification between emulated thread crashes and errant user changes – a contribution believed to be unique to this research. Lastly, future research avenues and conclusions in automated fault identification are described along with lessons learned throughout this endeavor. This includes the progression of artificial neural networks, how learning algorithms are being developed and understood, and possibilities for automatically generating feature locality data.
256

Sistema inteligente baseado em decomposição por componentes ortogonais e inferência fuzzy para localização de faltas de alta impedância em sistemas de distribuição de energia elétrica com geração distribuída / Intelligent system based on orthogonal decomposition technique and fuzzy inference for high impedance location fault in distribution systems with distributed generation

Batista, Oureste Elias 28 March 2016 (has links)
Os sistemas elétricos de potência modernos apresentam inúmeros desafios em sua operação. Nos sistemas de distribuição de energia elétrica, devido à grande ramificação, presença de extensos ramais monofásicos, à dinâmica das cargas e demais particularidades inerentes, a localização de faltas representa um dos maiores desafios. Das barreiras encontradas, a influência da impedância de falta é uma das maiores, afetando significativamente a aplicação dos métodos tradicionais na localização, visto que a magnitude das correntes de falta é similar à da corrente de carga. Neste sentido, esta tese objetivou desenvolver um sistema inteligente para localização de faltas de alta impedância, o qual foi embasado na aplicação da técnica de decomposição por componentes ortogonais no pré-processamento das variáveis e inferência fuzzy para interpretar as não-linearidades do Sistemas de Distribuição com presença de Geração Distribuída. Os dados para treinamento do sistema inteligente foram obtidos a partir de simulações computacionais de um alimentador real, considerando uma modelagem não-linear da falta de alta impedância. O sistema fuzzy resultante foi capaz de estimar as distâncias de falta com um erro absoluto médio inferior a 500 m e um erro absoluto máximo da ordem de 1,5 km, em um alimentador com cerca de 18 km de extensão. Tais resultados equivalem a um grau de exatidão, para a maior parte das ocorrências, dentro do intervalo de ±10%. / Modern electric power systems present numerous challenges in its operation. Fault location is a major challenge in Power Distribution Systems due to its large branching, presence of single-phase laterals and the dynamic loads. The influence of the fault impedance is one of the largest, significantly affecting the use of traditional methods for its location, since the magnitude of the fault currents is similar to the load current. In this sense, this thesis aimed to develop an intelligent system for location of high impedance faults, which was based on the application of the decomposition technique of orthogonal components in the pre-processing variables and fuzzy inference to interpret the nonlinearities of Power Distribution Systems with the presence of Distributed Generation. The data for training the intelligent system were obtained from computer simulations of an actual feeder, considering a non-linear modeling of the high impedance fault. The resulting fuzzy system was able to estimate distances to fault with an average absolute error of less than 500 m and a maximum absolute error of 1.5 km order, on a feeder about 18 km long. These results are equivalent to a degree of accuracy for the most occurrences within the ± 10% range.
257

Estimador de variações de tensão de curta duração em sistemas elétricos de potência utilizando estratégias evolutivas. / Estimate short duration voltage variation using evolutionary strategies.

Guerra Zvietcovich, Wilingthon 19 September 2011 (has links)
Neste trabalho, é proposta uma metodologia para estimar o estado de um sistema elétrico de potência (SEPs) durante variações de tensão de curta duração (VTCDs) causadas por faltas elétricas nas linhas que compõem a rede elétrica avaliada. Para cumprir esta meta, são utilizados os valores registrados nos equipamentos de medição instalados nas redes elétricas. Na realidade, existem poucos equipamentos nas redes elétricas devido aos custos elevados dos medidores de qualidade de energia elétrica (QEE). Embora estes custos tenham diminuído nos últimos anos, ainda é inviável a utilização de um número suficiente de medidores para garantir a monitoração de toda a rede, por tornar-se muito oneroso. Esta realidade constitui um desafio para se desenvolver técnicas que permitam, a partir de um pequeno número de pontos de monitoração, determinar os locais de faltas e estimar os valores das VTCDs em todas as barras que compõem um sistema elétrico. Como contribuição à solução destes problemas, esta tese propõe a utilização do algoritmo denominado Estratégias Evolutivas (EEs), que integra a família dos Algoritmos Evolutivos. Tal algoritmo mostrou ser viável por sua facilidade de implementação e rapidez de resposta na busca de uma solução dentro de um vasto espaço de soluções. As EEs, nesta tese, são utilizadas para se determinar: o local de falta, tipo de falta e impedância de falta, que caracterizam um indivíduo, de forma que as tensões resultantes nas barras monitoradas sejam as mais próximas possíveis das medições realizadas. Para alcançar esse objetivo, inicialmente se constrói uma população inicial de indivíduos que representam alternativas de solução do problema. Em seguida, uma parte destes indivíduos será submetida a mutação e recombinação para então serem selecionados os indivíduos que sobreviverão na geração futura. Este processo iterativo é realizado até que se encontre uma solução o mais próximo da procurada. Cada indivíduo é avaliado através de função objetivo, que representa o erro quadrático entre os valores medidos e os valores calculados. Para este cálculo, é necessário simular um curto-circuito com as características do indivíduo avaliado com base em informações da rede bem como dos valores das tensões provenientes dos medidores. A partir da determinação das características da falta, é feita a estimação dos valores das tensões em toda a rede levando à avaliação das VTCDs. Uma vez atingido este objetivo, é possível, por exemplo, determinar indicadores de qualidade associados às VTCDs, como o SARFI (System Average RMS Frequency Index), determinar as áreas mais propensas a causar as VTCDs e elaborar planos de manutenção preventiva. Foram implementados dois algoritmos que calculam o número mínimo de medidores e os locais onde estes devem ser instalados. O primeiro algoritmo tem a finalidade de garantir o monitoramento de toda a rede em relação às VTCDs enquanto o segundo garante o menor erro de estimação de VTCDs nas barras onde não se têm medidores instalados. A referida metodologia pode ser aplicada em redes radiais ou em malha, sendo inicialmente aplicada em sistemas de pequeno porte (redes de 14 e 30 barras do IEEE) com intuito de verificar a capacidade do algoritmo. Foram então simuladas redes de maior complexidade, por meio de testes em redes de 57 barras e 118 barras do IEEE. Para avaliar a eficiência da metodologia desenvolvida foi feita uma comparação com outra metodologia de otimização baseada em Algoritmos Genéticos (AGs). / A methodology is herein proposed to estimate Short Duration Voltage Variation (SDVV) in electric power systems, caused by electrical faults. To attain this target, values recorded by measurement equipment in specific sites are used. In fact, there are few power quality meters installed in power networks, due to the high cost of such meters. Although these costs have decreased in recent years, the installation of a sufficient number of meters to ensure monitoring the entire network is still unfeasible. This reality poses a challenge to developing techniques that, with a small number of monitoring points, allow the determination of fault locations and estimation of SDVV values in specified buses. As contribution this thesis proposes an algorithm called Evolutionary Strategies (ESE), which integrates the group of evolutionary algorithms. This algorithm can be easily implemented and finds a solution within a wide solution space. The ESE determines the fault location, fault type and fault impedance, that characterize an individual, so that the resulting voltages on monitored buses are as close as possible to the measured ones. An initial population is generated as alternative solutions to the problem. Some of the individuals in the population will be submitted to mutation and recombination operators. Individuals are then selected to the future generation. An iterative process is carried out to determine a solution as close as possible to the desired one. Each individual is evaluated by the objective function, which represents the quadratic error between the measured and calculated values. This calculation is based on short circuit calculation related to the evaluated individual and from information of voltage values gathered from power quality meters. Voltage values in specific network buses can then be determined to monitor their corresponding SDVV values. This allows, for example, determining quality indicators associated to the SDVV, such as the System Average RMS Frequency Index (SARFI), to evaluate sensitive areas, i.e. which are prone to cause SDVVs and to develop plans for preventive maintenance. Two algorithms that calculate the minimum number of meters and their locations have been implemented. The first algorithm aims to ensure monitoring the entire network regarding SDVVs, while the second algorithm ensures the smallest error of SDVV estimation in buses where no meters are installed. This methodology can be applied to meshed or radial networks. It was initially implemented in small networks (IEEE 14 and 30 buses) with the purpose of verifying the ability of algorithm. In sequence the methodology was applied to more complex networks (IEEE 57 and 118 buses). To assess the efficiency of the methodology a comparison with other optimization methodology based on Genetic Algorithms (GA) was carried out.
258

A localização de faltas em um sistema de distribuição radial baseada na aplicação de árvores de decisão e redes neurais artificiais / Fault location in a radial distribution system based on the application of decision trees and artificial neural networks

Pessoa, André Luís da Silva 02 August 2017 (has links)
Os Sistemas de Distribuição (SDs), devido as suas topologias e configurações, dentre outros fatores, apresentam um desafio para a localização física das situações de faltas passíveis de ocorrência. Como fato, tem-se que uma localização de faltas, rápida e precisa, possibilita atenuar os transtornos que os usuários finais dos SDs viriam a ter em relação à qualidade do serviço prestado pelas distribuidoras. No contexto das redes elétricas inteligentes, e considerando medidores de qualidade da energia elétrica previamente alocados de forma otimizada, esta pesquisa propõe uma metodologia baseada em árvores de decisão e redes neurais artificiais para a localização de faltas em SDs radiais e aéreos. Foram realizados testes da metodologia proposta considerando variações no tipo, na impedância e no ângulo de incidência da falta aplicadas sobre o SD de 34 barras do IEEE (Institute of Electrical and Electronics Engineers). Para os testes de sensibilidade da metodologia desenvolvida, foram consideradas variações no carregamento do sistema, os erros inerentes ao sistema de medição, a variação no número de medidores disponível, o impacto de uma alocação não otimizada dos medidores e uma redução na taxa amostral. Os resultados encontrados foram promissores e indicam que a metodologia como desenvolvida poderá ser aplicada para SDs diferentes do caso teste utilizado. / Due to the distribution systems (DS) topologies, configurations and among other factors, it is a challenge to physically locate situations of faults. As a matter of fact, a fast and accurate fault location will make it possible to mitigate the inconvenience that the end users of DS would have due to the quality of the service provided by the distributors. In the context of intelligent electric grids, and considering the electric power quality meters optimally alocated, this research proposes a methodology based in decision trees and artificial neural networks for a fault location in radial and aerial DS. The proposed methodology was tested considering variations on the type, impedance and angle of incidence of the fault applied on the DS of 34 bars of the IEEE (Institute of Electrical and Electronic Engineers). For a sensitivity test of the developed methodology, it were considered the variations in system loading, the errors inherent to the measurement system, a variation in number of meters available, the impact of the non-optimized allocation of the meters and a redution on the sampling rate. The results were promising and indicated that the methodology developed can be applied to different DS from the test case used.
259

Análise crítica da rota tecnológica adotada no desenvolvimento de equipamento sinalizador de faltas para redes aéreas de distribuição de energia elétrica. / Critical analysis of the technological route adopted for development of faulted circuit indicator equipment for aerial power distribution network.

Andrade, Fábio José de 20 April 2012 (has links)
Um equipamento sinalizador luminoso de faltas foi desenvolvido pela Companhia Paulista de Força e Luz (CPFL) em parceria com a Escola Politécnica da USP e a empresa Expertise Engenharia Ltda., através de uma série de projetos de pesquisa incluídos no programa de pesquisa e desenvolvimento (P&D) regido pela Agência Nacional de Energia Elétrica (ANEEL) brasileira. Neste trabalho é feita uma análise crítica da rota tecnológica adotada no desenvolvimento do sinalizador de faltas, apontando detalhes e justificativas das escolhas tecnológicas adotadas, além de novas possibilidades de melhoria do equipamento face aos avanços tecnológicos detectados nos últimos anos. Para tanto, é proposto e aplicado um novo método, associado a uma sistematização, para análise comparativa de tecnologias, que considera dados quantitativos, qualitativos e estratégicos diretamente comparáveis entre si. Ao longo do trabalho são analisados as escolhas dos princípios de detecção de faltas e funcionalidades agregadas, o desenvolvimento da eletrônica e dos circuitos integrados do detector de faltas, a fonte de alimentação, a sinalização luminosa e o gabinete do equipamento. Como resultado da linha de pesquisa do sinalizador luminoso de faltas foram obtidos protótipos de prova de conceito, cabeça-de-série e de lote pioneiro, estes últimos prontos e certificados para inserção no mercado. Obtiveram-se também diversas publicações em congressos nacionais, a geração de dois pedidos de patentes e um sistema computacional de alocação otimizada de sinalizadores de faltas em redes de distribuição aérea de energia elétrica. / Within the R&D program governed by the National Agency of Electric Energy of Brazil, a luminous faulted circuit indicator equipment (FCI) was developed by the Companhia Paulista de Força e Luz (CPFL) in partnership with the Escola Politécnica da USP and the company Expertise Engenharia Ltda. In this work it is presented a critical analysis of the technological route adopted for development of this new FCI, indicating details and justifications of technological choices adopted, and new detected possibilities for improvements, taken into account the technological advances in recent years. For such purpose, it is proposed a new method, associated to a practical systematization, for comparative analysis of technologies that accounts for quantitative, qualitative and strategic data directly comparable. The work presents analyses on the choices of fault detection principles and related functions, the development of integrated circuits and fault detector electronics, the power supply, the luminous signaling and the equipment case. As results of the research and development of the FCI there were obtained proof of concept, prototype and pilot equipments, the last ones certified and ready for sale. There were also obtained several publications in national conferences, submission of two patent applications and a software for optimization of FCIs allocation on overhead power distribution networks.
260

Diagnóstico de curtos-circuitos a partir da alocação otimizada de medidores em um sistema de distribuição subterrâneo / Diagnostic short-circuits from the optimized allocation meters in a underground distribution system

Festa, Alexandre Vinícius 12 February 2015 (has links)
O monitoramento e diagnóstico, com a consequente localização dos curtos-circuitos em Sistemas de Distribuição (SD), fazem parte de um processo complexo, exigindo esforços e agilidade das equipes técnicas de manutenção das concessionárias de energia elétrica. Quando se trata de um SD Subterrâneo (SDS), a complexidade de localização das faltas aumenta, pois não é possível realizar a inspeção visual. Por este motivo, desenvolver e aprimorar métodos para monitorar, classificar e localizar as situações de faltas em SD tem sido de relevante interesse para a comunidade técnico-científica nos últimos anos. Neste contexto, apresenta-se nesta pesquisa um método para processar as informações necessárias para classificar e localizar a ocorrência de um curto-circuito (monofásico, bifásico e/ou trifásico, com e/ou sem o envolvimento da terra) em um SDS. O processamento das informações foi realizado por meio da observação da propagação dos afundamentos de tensão, decorrentes de curtos-circuitos passíveis de ocorrência no SDS, e pela alocação de um número reduzido de medidores, permitindo a classificação e localização precisa da falta. Um dos diferenciais da metodologia proposta é que esta utiliza somente os valores eficazes das tensões trifásicas, registradas em medidores estrategicamente alocados, para indicação da área afetada e classificação das fases envolvidas. A metodologia é baseada no emprego de redes neurais artificiais. Os resultados encontrados são promissores, indicando a aplicabilidade da metodologia proposta. / The monitoring and diagnostics, with the consequent localization of short circuits in Distribution Systems (DS), are part of a complex process, requiring efforts and agility of the technical teams of maintenance of electric utilities. In the case of an underground DS (UDS), the location of faults complexity increases, because it is not possible to perform visual inspection. For this reason, develop and improve methods to monitor, sort and locate the fault situations in DS has been of relevant interest to the technical-scientific community in recent years. In this context, this study presents a method for processing the information required to classify and locate the occurrence of a short circuit (single phase, biphasic and / or phase with and / or without the involvement of the earth) on a UDS. The information processing was carried out by observing the propagation of voltage sags, caused by short circuits that may occur in the UDS, and the allocation of a few meters, allowing classification and precise location of the fault. One of the proposed methodology differentials is that it uses only the RMS values of the three-phase voltages, registered in strategically located meters, for indicating the affected area and classification of the phases involved. The methodology is based on the use of artificial neural networks. The results found are promising, indicating the applicability of the proposed methodology.

Page generated in 0.0421 seconds