• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 621
  • 172
  • 81
  • 28
  • 18
  • 10
  • 10
  • 7
  • 7
  • 7
  • 6
  • 6
  • 5
  • 5
  • 4
  • Tagged with
  • 1323
  • 1323
  • 1323
  • 487
  • 220
  • 154
  • 154
  • 146
  • 134
  • 126
  • 118
  • 118
  • 113
  • 98
  • 92
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
701

On Design and Analysis of a Novel Transverse Flux Generator for Direct-driven Wind Application

Svechkarenko, Dmitry January 2010 (has links)
This thesis deals with the analysis of a permanent magnet synchronous generator suited for direct-drivenwind turbines inmegawatt class. The higher specific torque and power density of a transverse flux permanent magnet machine in comparison to conventional radial-flux machines make it a promising solution for direct-driven wind turbine generators. The novel transverse flux generator investigated in this work would allow a better utilization of the available nacelle space due to its more compact construction. The major part of the thesis deals with the finite element analysis and analytical calculations of transverse flux generators. The computations are performed for single units of the basic transverse flux topology (BTFM) and the one utilizing iron bridges (IBTFM). As the selection of the pole length in a transverse flux machine affects the pole-to-pole flux leakage and thus its performance, the topologies have been analyzed with respect to the varying dimensions in the direction of movement. The topologies utilizing IBTFM have been found to be superior to the BTFM with respect to the flux linkage (by 110%) and utilization of the magnets (by 84%). The machines with longest magnets gave the largest flux linkage, while machines with short magnets should be preferred for better magnet utilization. The four sets of dimensions have been selected for a dynamic finite element analysis. The power factor is evaluated for the topologies with the varying dimensions in the peripheral plane in static finite element analysis. The performance of the topologies with the best power factor in the studied range (0.62 in the BTFM and 0.57 in the IBTFM), as well as the topologies that give the highest power factor to magnet volume ratio, is compared with the dynamic simulations.The electromagnetic and cogging forces of the transverse-flux generator are estimated. The IBTFM is superior to the BTFM with respect to the force production, where the three-phase electromagnetic force is twice as large as in the BTFM. The force ripples of the three-phase electromagnetic force are found to be insignificant in both topologies. An analytical procedure based on the results from the finite element simulations is applied for evaluation of the transverse flux generators with different shapes and topologies. The effectiveness of each topology is investigated based on the estimation of the torque production in a certain nacelle volume. A toroidal generator with the iron-bridge topology is the most compact alternativefor a wind turbine as it has the highest torque-per-volume ratio. Furthermore, the analyticalmodel, including evaluation of the synchronous inductance, is developed and compared with the results obtained in the threedimensional finite element analysis. Themodel provides a good agreement for the studied set of dimensions. / QC 20101109
702

Influence of Rock Boundary Conditions on Behaviour of Arched and Flat Cemented Paste Backfill Barricade Walls

Cheung, Andrew 21 November 2012 (has links)
Current design of cemented paste backfill (CPB) barricades tends to be of unknown conservativeness due to limited understanding of their behaviour. Previous work done to characterize barricade response has not accounted for the effects of the surrounding rock stiffness, which can have significant impact on the development of axial forces which enhance capacity via compressive membrane action. Parametric analyses were performed with the finite element analysis program Augustus-2 to determine the effects of various material and geometric properties on barricade capacity. Equations based on Timoshenko and Boussinesq solutions were developed to model rock stiffness effects based on boundary material properties. An iterative simulation process was used to account for secondary moment effects as a proof of concept. It was found that, for a range of typical rock types, barricade capacity varied significantly. The commonly made design assumption of a fully rigid boundary resulted in unconservative overpredictions of strength.
703

Influence of Rock Boundary Conditions on Behaviour of Arched and Flat Cemented Paste Backfill Barricade Walls

Cheung, Andrew 21 November 2012 (has links)
Current design of cemented paste backfill (CPB) barricades tends to be of unknown conservativeness due to limited understanding of their behaviour. Previous work done to characterize barricade response has not accounted for the effects of the surrounding rock stiffness, which can have significant impact on the development of axial forces which enhance capacity via compressive membrane action. Parametric analyses were performed with the finite element analysis program Augustus-2 to determine the effects of various material and geometric properties on barricade capacity. Equations based on Timoshenko and Boussinesq solutions were developed to model rock stiffness effects based on boundary material properties. An iterative simulation process was used to account for secondary moment effects as a proof of concept. It was found that, for a range of typical rock types, barricade capacity varied significantly. The commonly made design assumption of a fully rigid boundary resulted in unconservative overpredictions of strength.
704

Thermal Management in Laminated Die Systems Using Neural Networks

Seo, Jaho 26 August 2011 (has links)
The thermal control of a die is crucial for the development of high efficiency injection moulds. For successful thermal management, this research provides an effective control strategy to find sensor locations, identify thermal dynamic models, and design controllers. By applying a clustering method and sensitivity analysis, sensor locations are identified. The neural network and finite element analysis techniques enable the modeling to deal with various cycle-times for the moulding process and uncertain dynamics of a die. A combination of off-line training through finite element analysis and training using on-line learning algorithms and experimental data is used for the system identification. Based on the system identification which is experimentally validated using a real system, controllers are designed using fuzzy-logic and self-adaptive PID methods with backpropagation (BP) and radial basis function (RBF) neural networks to tune control parameters. Direct adaptive inverse control and additive feedforward control by adding direct adaptive inverse control to self-adaptive PID controllers are also provided. Through a comparative study, each controller’s performance is verified in terms of response time and tracking accuracy under different moulding processes with multiple cycle-times. Additionally, the improved cooling effectiveness of the conformal cooling channel designed in this study is presented by comparing with a conventional straight channel.
705

Design And Modeling Elastomeric Vibration Isolators Using Finite Element Method

Ardic, Halil 01 February 2013 (has links) (PDF)
In this thesis, a process is developed for designing elastomeric vibration isolators in order to provide vibration isolation for sensitive equipment being used in ROKETSAN A.S.&rsquo / s products. For this purpose, first of all, similar isolators are examined in the market. After that, appropriate elastomeric materials are selected and their temperature and frequency dependent dynamic properties are experimentally obtained. Parametric finite element model of the isolator is then constituted in ANSYS APDL using the properties of elastomeric materials and the conceptual design of the isolator. Then, according to design requirements, final design parameters of the vibration isolator are determined at the end of design iterations. In the next step, vibration isolator that was designed is manufactured using the elastomeric material chosen, by a local rubber company. Finally, design process is verified by comparing analysis and test results.
706

Failure Analysis Of Thick Composites

Erdem, Melek Esra 01 February 2013 (has links) (PDF)
A three-dimensional finite element model is constructed to predict the failure of a hybrid and thick laminate containing bolted joints. The results of the simulation are compared with test results. The simulation comprises two main challenging steps. Firstly, for a realistic model, a 3D model is established with geometric nonlinearities and contact is takeninto account. The laminated composite model is constructed by 3D layered elements. The effect of different number of elements through the thickness is investigated. The failure prediction is the second part of the simulation study. Solutions with and without progressive failure approach are obtained and the effect of progressive failure analysis for an optimum simulation of failure is discussed. The most appropriate failure criteria to predict the failure of a thick composite structure is also investigated by considering various failure criteria. By comparing the test results with the ones found from the finite element analyses, the validity of the developed model and the chosen failure criteria are discussed.
707

Seismic Performance Assessment of Multi-Storey Buildings with Cold Formed Steel Shear Wall Systems

Martinez Martinez, Joel January 2007 (has links)
Cold-Formed Steel (CFS) is a material used in the fabrication of structural and non-structural elements for the construction of commercial and residential buildings. CFS exhibits several advantages over other construction materials such as wood, concrete and hot-rolled steel (structural steel). The outstanding advantages of CFS are its lower overall cost and non-combustibility. The steel industry has promoted CFS in recent decades, causing a notable increase in the usage of CFS in building construction. Yet, structural steel elements are still more highly preferred, due to the complex analysis and design procedures associated with CFS members. In addition, the seismic performance of CFS buildings and their elements is not well known. The primary objective of this study is to develop a method for the seismic assessment of the lateral-load resistant shear wall panel elements of CFS buildings. The Performance-Based Design (PBD) philosophy is adopted as the basis for conducting the seismic assessment of low- and mid-rise CFS buildings, having from one to seven storeys. Seismic standards have been developed to guide the design of buildings such that they do not collapse when subjected to specified design earthquakes. PBD provides the designer with options to choose the performance objectives to be satisfied by a building to achieve a satisfactory design. A performance objective involves the combination of an earthquake (i.e., seismic hazard) and a performance level (i.e., limit state) expected for the structure. The building capacity related to each performance level is compared with the demand imposed by the earthquake. If the earthquake demand is less than the building capacity, the structure is appropriately designed. The seismic performance of a CFS building is obtained using pushover analysis, a nonlinear method of seismic analysis. This study proposes a Simplified Finite Element Analysis (SFEA) method to carry out the nonlinear structural analysis. In this study, lateral drifts associated with four performance levels are employed as acceptance criteria for the PBD assessment of CFS buildings. The lateral drifts are determined from experimental data. In CFS buildings, one of the primary load-resistant elements is Shear Wall Panel (SWP). The SWP is constructed with vertically spaced and aligned C-shape CFS studs. The ends of the studs are screwed to the top and bottom tracks, and structural sheathing is installed on one or both sides of the wall. For the analysis of CFS buildings, Conventional Finite Element Analysis (CFEA) is typically adopted. However, CFEA is time consuming because of the large number of shell and frame elements required to model the SWP sheathing and studs. The SFEA proposed in this study consists of modeling each SWP in the building with an equivalent shell element of the same dimensions; that is, a complete SWP is modeled by a 16-node shell element. Thus, significantly fewer elements are required to model a building for SFEA compared to that required for CFEA, saving both time and resources. A model for the stiffness degradation of a SWP is developed as a function of the lateral strength of the SWP. The model characterizes the nonlinear behaviour of SWP under lateral loading, such that a realistic response of the building is achieved by the pushover analysis. The lateral strength of a SWP must be known before its seismic performance can be assessed. In current practice, the lateral strength of a SWP is primarily determined by experimental tests due to the lack of applicable analytical methods. In this investigation, an analytical method is developed for determining the ultimate lateral strength of SWP, and associated lateral displacement. The method takes into account the various factors that affect the behaviour and the strength of SWP, such as material properties, geometrical dimensions, and construction details. To illustrate the effectiveness and practical application of the proposed methodology for carrying out the PBD assessment of CFS buildings, several examples are presented. The responses predicted by the SFEA are compared with responses determined experimentally for isolated SWP. In addition, two building models are analyzed by SFEA, and the results are compared with those found by SAP2000 (2006). Lastly, the PBD assessment of two buildings is conducted using SFEA and pushover analysis accounting for the nonlinear behaviour of the SWP, to demonstrate the practicality of the proposed technology.
708

Vertical Displacements in a Medium-rise Timber Building : Limnologen in Växjö, Sweden

Zeng, Xiong yu, Ren, Su Xin, Omar, Sabri January 2009 (has links)
Träbyggnandet i Sverige gick in i en ny era när myndigheterna beslutade att upphäva förbudet mot att bygga byggnader som är högre än två våningar. Denna förändring i lagstiftningen har bidragit till att utveckla träbyggandet under det senaste decenniet. Cross Laminerat Timber (CLT) har blivit erkänt som en ny teknik som använt på ett korrekt sätt ger starka och pålitliga konstruktioner. Materialet visar sig mer och mer intressant huvudsakligen beroende på den styvhet och styrka det visar i olika tester. Ett av de projekt som använt CLT som bärande element är Limnologen i staden Växjö 500 kilometer söder om Stockholm. I detta projekt har både väggar och bjälklag med bärande delar av CLT använts. En av utmaningarna i samband med högre träbyggande är att beräkna och ta hänsyn till de vertikala förskjutningarna i stommen. Orsakerna till förskjutningen är momentana samt tidsberoende. I denna uppsats utvärderas dessa vertikala förskjutningar med två olika metoder. Den första av dessa är experimentell. Förskjutningarna mättes av en grupp forskare från Växjö universitet och utvärderas i denna rapport. Den andra är en Finit Element Modell där förskjutningarna simuleras beroende på parametrar som anses viktiga. Resultatet av simuleringen jämförs med de experimentellt erhållna värdena. Simulering är ett viktigt sätt att förutsäga förskjutningar i CLT byggnader i framtiden. Alla modeller har gjorts med hjälp av finita element programmet Abaqus. FEM- modellen av Limnologen består av ett väggelement per våning i sex våningar. Detta element är det element där också förskjutningarna mätts på plats. På så sätt kan modell och verklighet jämföras. Förutom väggelement modelleras också bjälklagselement och kopplingen mellan vägg och bjälklag. De experimentella resultaten har analyserats i programvaran Matlab. Resultatet blev ett antal grafer som redovisar förloppet. Det viktigaste resultatet är det som visar både den totala relativa förskjutningen samtidigt som den visar fuktkvoten i CLT- skivan. Fuktkvoten beräknades från temperatur och relativ luftfuktighet som båda mättes på plats. Slutsatsen är att man med en simulering kan åstadkomma en acceptabel tillförlitlighet med avseende på vertikala förskjutningar. Krympningen har spelat en viktig roll för förskjutningarna. Den maximala förskjutningen som erhållits från mätningar var 21 mm medan det maximala förskjutningen fått från simuleringen baserad på tre olika antaganden var 35 mm, 33 mm och 17 mm. Skillnaden i resultaten kan delvis förklaras av de antaganden som använts för beräkning av fuktkvot och antagandet om fiberriktningen i timret. I simuleringen antogs fuktkvoten vara konstant över alla tre lager i CLT- skivan i de två första fallen. Orienteringen av fibrerna antogs radiell och tangentiell. Det tredje antagandet bygger på att fukten enbart påverkar det yttersta lagret i skivan. Detta antagande är rimligt på grund av tidsåtgången att uppnå fuktjämvikt och på grund av det limlager som skiljer lagren åt och hindrar fukt att vandra från ett lager till ett annat. / The history of timber buildings in Sweden entered a new era when the authorities decided to lift the ban on constructing more than two-storey timber buildings in Sweden. This change in legislations has contributed to the emergence of timber construction during the last decade. The Cross Laminated Timber (CLT) has become recognized as a new technology that used correctly in construction gives strong and reliable structures. The building material is gaining more credit day by day mainly due to the stiffness and strength it proved throughout the tests in projects where it was used. One of the projects that used CLT as load bearing elements was Limnologen in the city of Växjö 500 kilometres south of Stockholm. In this project, a system of CLT floors as well as CLT walls has been used. One of the challenges related to medium-rise timber buildings in general is to calculate and take account of the vertical displacement of the whole building. The sources for the displacements are instantaneous elastic as well as time dependent. In this thesis we are introducing two evaluation methods for the vertical displacements in Limnologen. The first is the experimentally measured vertical displacement that was performed by a group of researchers from Växjö University, and the second is a Finite Element Model simulating the vertical displacement according to the factors and parameters thought to be important to be included in the modelling. The output of the simulation was to be compared with the experimentally obtained values. Simulation is an important way to predict the vertical displacement in future CLT buildings. All modelling were done using the finite element software Abaqus. The Abaqus model of the Limnologen building consists of six wall elements from six storeys. The modelled wall elements are the wall elements that the vertical displacement devices were installed on. The reason for this is to get a better picture of how the results from the model would yield in comparison to the site measurements. The floor itself and the sylodyn used in the interface between wall and floor were also modelled. The data collected from the site were processed in the software Matlab. Several graphs were attained out of the data processing. The most important graph is the one that include both the total relative displacement and the equivalent moisture content in the CLT. The equivalent moisture content was calculated from the measured temperature and relative humidity. In this thesis it is concluded that a simulation can accomplish an acceptable reliability with respect to the vertical displacements. The shrinkage factor has played a vital role in simulation of the displacements. The maximum displacement obtained from the measurements was 21 mm while the maximum displacement gained from the simulation based on three different assumptions was 35 mm, 33 mm, and 17 mm respectively with the similar displacement pattern. The difference in the results can partly be explained by the assumptions used for the equivalent moisture content and local coordinate system of the CLT layers. In the simulation the moisture content was assumed to be equal over each layer of the CLT-panel. The first two assumptions were formulated due to the amphibolous grain of the middle layer of the CLT-panel which was considered having effect on the vertical displacement. The third assumption was formulated due to the glue layer between the wood layers of the CLT-panel which was considered having effect on preventing moisture diffuse from one layer to another layer. In reality it is questionable if the moisture content is varied in the different layers of the CLT-panel. The diffusion of the moisture content hasn't been taken into account.
709

Evaluation of an Interphase Element using Explicit Finite Element Analysis

Svensson, Daniel, Walander, Tomas January 2008 (has links)
A research group at University of Skövde has developed an interphase element for implementation in the commercial FE-software Abaqus. The element is using the Tvergaard & Hutchinson cohesive law and is implemented in Abaqus Explicit version 6.7 using the VUEL subroutine. This bachelor degree project is referring to evaluate the interphase element and also highlight problems with the element. The behavior of the interphase element is evaluated in mode I using Double Cantilever Beam (DCB)-specimens and in mode II using End Notch Flexure (ENF)-specimens. The results from the simulations are compared and validated to an analytical solution. FE-simulations performed with the interphase element show very good agreement with theory when using DCB- or ENF-specimens. The only exception is when an ENF-specimen has distorted elements. When using explicit finite element software the critical time step is of great importance for the results of the analyses. If a too long time step is used, the simulation will fail to complete or complete with errors. A feasible equation for predicting the critical time step for the interphase element has been developed by the research group and the reliability of this equation is evaluated. The result from simulations shows an excellent agreement with the equation when the interphase element governs the critical time step. However when the adherends governs the critical time step the equation gives a time step that is too large. A modification of this equation is suggested.
710

Seismic Performance Assessment of Multi-Storey Buildings with Cold Formed Steel Shear Wall Systems

Martinez Martinez, Joel January 2007 (has links)
Cold-Formed Steel (CFS) is a material used in the fabrication of structural and non-structural elements for the construction of commercial and residential buildings. CFS exhibits several advantages over other construction materials such as wood, concrete and hot-rolled steel (structural steel). The outstanding advantages of CFS are its lower overall cost and non-combustibility. The steel industry has promoted CFS in recent decades, causing a notable increase in the usage of CFS in building construction. Yet, structural steel elements are still more highly preferred, due to the complex analysis and design procedures associated with CFS members. In addition, the seismic performance of CFS buildings and their elements is not well known. The primary objective of this study is to develop a method for the seismic assessment of the lateral-load resistant shear wall panel elements of CFS buildings. The Performance-Based Design (PBD) philosophy is adopted as the basis for conducting the seismic assessment of low- and mid-rise CFS buildings, having from one to seven storeys. Seismic standards have been developed to guide the design of buildings such that they do not collapse when subjected to specified design earthquakes. PBD provides the designer with options to choose the performance objectives to be satisfied by a building to achieve a satisfactory design. A performance objective involves the combination of an earthquake (i.e., seismic hazard) and a performance level (i.e., limit state) expected for the structure. The building capacity related to each performance level is compared with the demand imposed by the earthquake. If the earthquake demand is less than the building capacity, the structure is appropriately designed. The seismic performance of a CFS building is obtained using pushover analysis, a nonlinear method of seismic analysis. This study proposes a Simplified Finite Element Analysis (SFEA) method to carry out the nonlinear structural analysis. In this study, lateral drifts associated with four performance levels are employed as acceptance criteria for the PBD assessment of CFS buildings. The lateral drifts are determined from experimental data. In CFS buildings, one of the primary load-resistant elements is Shear Wall Panel (SWP). The SWP is constructed with vertically spaced and aligned C-shape CFS studs. The ends of the studs are screwed to the top and bottom tracks, and structural sheathing is installed on one or both sides of the wall. For the analysis of CFS buildings, Conventional Finite Element Analysis (CFEA) is typically adopted. However, CFEA is time consuming because of the large number of shell and frame elements required to model the SWP sheathing and studs. The SFEA proposed in this study consists of modeling each SWP in the building with an equivalent shell element of the same dimensions; that is, a complete SWP is modeled by a 16-node shell element. Thus, significantly fewer elements are required to model a building for SFEA compared to that required for CFEA, saving both time and resources. A model for the stiffness degradation of a SWP is developed as a function of the lateral strength of the SWP. The model characterizes the nonlinear behaviour of SWP under lateral loading, such that a realistic response of the building is achieved by the pushover analysis. The lateral strength of a SWP must be known before its seismic performance can be assessed. In current practice, the lateral strength of a SWP is primarily determined by experimental tests due to the lack of applicable analytical methods. In this investigation, an analytical method is developed for determining the ultimate lateral strength of SWP, and associated lateral displacement. The method takes into account the various factors that affect the behaviour and the strength of SWP, such as material properties, geometrical dimensions, and construction details. To illustrate the effectiveness and practical application of the proposed methodology for carrying out the PBD assessment of CFS buildings, several examples are presented. The responses predicted by the SFEA are compared with responses determined experimentally for isolated SWP. In addition, two building models are analyzed by SFEA, and the results are compared with those found by SAP2000 (2006). Lastly, the PBD assessment of two buildings is conducted using SFEA and pushover analysis accounting for the nonlinear behaviour of the SWP, to demonstrate the practicality of the proposed technology.

Page generated in 0.0746 seconds