• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 268
  • 234
  • 21
  • 16
  • 8
  • 5
  • 5
  • 5
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • 4
  • Tagged with
  • 666
  • 666
  • 225
  • 218
  • 108
  • 83
  • 81
  • 70
  • 64
  • 49
  • 48
  • 45
  • 45
  • 41
  • 38
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
431

Preparação, caracterização e avaliação de carbono funcionalizado para aplicações em células a combustível tipo PEM / Preparation, characterization and evaluation of electrocatalysts supported on functionalized carbon black for polymer exchange membrane fuel cell applications

CARMO, MARCELO do 09 October 2014 (has links)
Made available in DSpace on 2014-10-09T12:53:44Z (GMT). No. of bitstreams: 0 / Made available in DSpace on 2014-10-09T13:58:46Z (GMT). No. of bitstreams: 0 / A tecnologia de células a combustível associada à crescente exigência de baixo impacto ambiental tornou-se bastante promissora no cenário mundial de energia. As células a combustível são, em princípio, dispositivos que convertem energia química diretamente em energia elétrica e térmica, possuindo, entretanto, uma operação contínua, graças à alimentação constante de um combustível. Particularmente, o negro de fumo Vulcan XC72 é usualmente empregado como suporte dos eletrocatalisadores, e alguns fatores como uma superfície acessível e área superficial suficientemente grande para uma máxima dispersão dos cristalitos dos eletrocatalisadores, além de tamanho dos poros, distribuição dos poros adequada e a presença de grupos funcionais na superfície do negro de fumo são considerados fundamentais para o desenvolvimento de materiais inovadores. Entretanto, o material denominado Vulcan XC72 ainda revela condições insuficientes para este fim. Este estudo consiste na preparação e caracterização físico-química de carbono funcionalizado por peróxido de hidrogênio e com cadeias poliméricas do tipo poliestireno sulfonado condutoras de prótons, visando sua posterior utilização como suporte de eletrocatalisadores para células a combustível tipo PEMFC e DMFC. Após a funcionalização do carbono, obteve-se uma melhora da dispersibilidade do negro de fumo em solução aquosa, efeito este benéfico para a preparação dos eletrocatalisadores. Observou-se também que os grupos funcionais e as cadeias poliméricas funcionaram como estabilizadores do crescimento dos cristalitos produzindo catalisadores mais homogêneos e com menor diâmetro médio dos cristalitos; e especialmente, no caso da funcionalização com cadeias poliméricas, obteve-se uma diminuição da queda ôhmica do sistema, referente à melhoria da transferência protônica. / Tese (Doutoramento) / IPEN/T / Instituto de Pesquisas Energéticas e Nucleares - IPEN-CNEN/SP
432

Avaliação da esterilização de filme de polietileno com peroxido de hidrogenio e radiação ultravioleta / Sterilization evaluation of low density polyethylene film with hydrogen peroxide and ultraviolet radiation

Cardoso, Claudio Fernandes 04 November 2007 (has links)
Orientador: Jose de Assis Fonseca Faria / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia de Alimentos / Made available in DSpace on 2018-08-08T11:53:49Z (GMT). No. of bitstreams: 1 Cardoso_ClaudioFernandes_M.pdf: 1146025 bytes, checksum: 703b38e7eec6c1ffc7f2de65b30ab581 (MD5) Previous issue date: 2007 / Resumo: O objetivo deste trabalho consistiu no processamento e avaliação de desempenho de um sistema asséptico piloto para filme de polietileno de baixa densidade (PEBD). Através da metodologia de planejamento experimental fatorial foram feitas variações de tempo de contato, temperatura do banho e concentração da solução esterilizante, bem como a variação do tempo de exposição à radiação ultravioleta (UVC). Estas variações tiveram por finalidade promover de 4 a 6 reduções decimais na população inicial de esporos de Bacillus subtilis var. globigii ATCC9372, em um curto espaço de tempo, gerando o menor residual do esterilizante em água envasada. Foram inoculados uniformemente 100µL do microrganismo teste em uma superfície de 16cm2. Testou-se como agente de esterilização química, o peróxido de hidrogênio (H2O2) e, como agente físico, a radiação UVC, sendo o primeiro aplicado na forma de banho de imersão e o segundo, por uma exposição a 2,5cm de distância do filme de PEBD logo após o banho de imersão. O sistema utilizado constituiu em uma envasadora automática e um protótipo com um tanque em aço inoxidável, desenvolvido especialmente para este tipo de teste. O H2O2 e a radiação UVC apresentaram ação esporicida significativa. O H2O2 demonstrou ação esporicida entre as concentrações de 18 e 35%, em um intervalo de temperatura de 46 a 70ºC, promovendo de 3 a 7 reduções decimais de Bacillus subtilis. A concentração de 20% de H2O2 não conferiu sabor estranho à água mineral envasada em embalagens de PEBD sanificadas, não diferindo, significativamente (p<0,05), do padrão. O residual de H2O2 das superfícies-teste sanificadas com soluções contendo de 18 a 35% de H2O2 foi superior a 0,5mg/L, nível máximo permitido pela FDA presente em água envasada sob as condições de produção. Os dados obtidos forneceram dois modelos matemáticos quadráticos, representativos da ação do H2O2 e radiação UVC, em função do tempo e da temperatura, sobre esporos de B. subtilis. Tais modelos, com R2 de 0,9349 para os tratamentos sem radiação UVC, e R2 de 0,9763 para os tratamentos com radiação UVC, limitaram-se a uma concentração de 35% de H2O2 e tempo máximo de exposição à radiação UVC de 8s. Superfícies-teste sanificadas com soluções de 28% de H2O2 a 60ºC, por 8s sem exposição à radiação UVC apresentaram 4 ciclos de redução decimal. Para as mesmas condições, porém com exposição à radiação UVC por 8s, este valor elevou-se para 7, demonstrando a existência do sinergismo entre a associação destes dois agentes. O sistema de esterilização testado apresentou desempenho satisfatório, podendo ser perfeitamente utilizado por indústrias de pequeno e médio porte na esterilização de filmes plásticos, sendo capaz de promover até 7 reduções decimais na população de esporos bacterianos / Abstract: The aim of this research consisted in the processing and performance evaluation of an aseptic pilot system for Low Density Polyethylene film (LDPE). Through the screening design methodology, variations of contact time, bath temperature, sanificant concentration and exposition time variation of ultraviolet radiation (UVC) was made. Such variations had as purpose to promote from 4 to 6 decimal reductions in the Bacillus subtilis var. globigii ATCC9372 spores, when applied to the LDPE film surface, in a short time, generating the minor residual of the sanificant in the plastic surface. Was evaluated as chemical agent, the hydrogen peroxide (H2O2) and as physical agent, UVC radiation, being the first one applied as immersion bath and the second one as an exposition after the immersion bath, with 2,5cm of distance of the PEBD film. The system used was constituted in an automatic filling machine and an equipment with a stainless steel tank, especially developed for this type of test. H2O2 showed sporicidal action in from 18 to 35%, in temperatures of 46 to 70ºC, causing from 3 to 7 decimal reductions. The H2O2 20% did not confer off-taste in mineral water used as filling product, as well no significant difference from the standard was observed (p<0,05). The hydrogen peroxide residual surface-test after sanitation with 18 to 35% H2O2 was higher than 0,5mg/L. However, the use of hot air knives or roller pressers after the immersion bath will be able to diminish this residual. The quadratic model, with R2 of 0,9349 for the treatments without UVC radiation and R2 of 0,9763 for the treatments with UVC radiation are restricted to 35% H2O2 and UVC maximum exposition time of 8s. Surface-test treated with 28% H2O2 / 60ºC / 8s without UVC radiation exposition had presented 4 decimal reduction. In the same conditions, however with UVC radiation exposition (8s), this value was raised for 7, demonstrating the existence of synergism between these two agents. The sanification system tested showed satisfactory performance, effective to be used in small and medium industries, being capable to promote up to 7 decimal reductions in spores population / Mestrado / Mestre em Tecnologia de Alimentos
433

Modulação da secreção de insulina por estresse oxidativo induzido em ilhotas pancreáticas de animais submetidos à desnutrição protéica / Oxidative stress modulation of insulin secretion in protein undernourished rats' pancreatic islet

Cappelli, Ana Paula Gameiro, 1984- 12 November 2009 (has links)
Orientador: Everardo Magalhães Carneiro / Dissertação (mestrado) - Universidade Estadual de Campinas, Instituto de Biologia / Made available in DSpace on 2018-08-16T00:20:04Z (GMT). No. of bitstreams: 1 Cappelli_AnaPaulaGameiro_M.pdf: 8746314 bytes, checksum: fffd531f3decda018f572cfc7c7f2be6 (MD5) Previous issue date: 2009 / Resumo: A desnutrição protéica promove redução da secreção de insulina devida inúmeras alterações moleculares nas células B pancreáticas. Recentemente foi demonstrado que o estado redox pode modular a secreção de insulina em condições fisiológicas. No entanto, a correlação entre as alterações no estado redox e na secreção de insulina em ratos submetidos à desnutrição protéica não é conhecida. Assim, nosso objetivo foi avaliar o impacto do estresse oxidativo na secreção de insulina em ilhotas de ratos desnutridos. Ratos machos Wistar foram tratados com dieta normoprotéica (NP-17%) ou hipoprotéica (LP-6%) por 60 dias. Após isolamento das ilhotas, foi medida atividade e o conteúdo protéico das enzimas antioxidantes SOD, GPx e a CAT. Para a secreção estática de insulina, as ilhotas foram pré-incubadas em 5.6 mM de glicose (GLI) com ou sem H2O2, na ausência ou presença de n-acetil cisteína (NAC) e posteriormente incubadas em diferentes concentrações de GLI. Observamos aumento da atividade da SOD (21.18±2.1-30.5.±2 µmoles/min/mg proteína NP-LP respectivamente), redução na CAT (9±1.2-5.22±0.73 µmoles/min/mg proteína NP-LP respectivamente) e nenhuma alteração na GPx em ilhotas de ratos desnutrido comparada com ilhotas de ratos controle. Apesar de observarmos tendência de aumento no conteúdo protéico das enzimas antioxidantes em LP, não houve diferença significativa de nenhuma das enzimas. A secreção de insulina de ratos LP que ficaram expostas a 33mM de glicose na incubação, retornou a níveis basais (GLI 2.8 mM) quando préincubado com 100 µM de H2O2, enquanto para as ilhotas de ratos controle foi necessário a adição de 300 ?M de H2O2 na pré-incubação para retornar aos níveis basais. Na presença de 10 mM de NAC + 150 µM de H2O2, durante a pré-incubação, e posterior incubação em 33 mM de glicose, observou-se redução significante da secreção de NP e aumento em LP. Estes resultados sugerem que as ilhotas pancreáticas de ratos desnutridos pré tratadas com H2O2 e posteriormente expostas a altas concentrações de glicose, são mais sensíveis ao H2O2 possivelmente devido à capacidade reduzida de detoxificação de espécies reativas de oxigênio (EROS). / Abstract: Protein malnutrition induces pacreatic B-cells molecular alterations, reducing insulin secretion. It has been recently demonstrated that redox status may control insulin secretion under physiological conditions. However, protein malnutrition effects in redox modulation of insulin secretion is unknown. Thus, our aim was to evaluate oxidative stress impact upon insulin secretion in isolated islets from protein undernourished rats. Male Wistar rats were treated with normoproteic diet (NP-17%) or with a low protein diet (LP-6%) for sixty days. After islets isolation, it was measured antioxidant enzymes SOD, GPX and CAT activities and protein content. For insulin secretion measurement, islets were pre-incubated with glucose 5.6 (GLI) mM with or without H2O2 at the presence and absence of N-acetyl-cisteyne (NAC) and after that islets were incubated with diferent GLI concentration. SOD and CAT activities were significant increased (21.18±2.1-30.5.±2 µmoles/min/mg protein for NP-LP respectively) and decreased (9±1.2-5.22±0.73 µmoles/min/mg protein for NP-LP respectively) respectively, whereas GPX did not show any alteration. Despite a tendency of increase in the LP protein content of antioxidant enzymes, no significant differences were observed. When incubated with glucose 33mM, LP insulin secretion returned to baseline values (GLI 2.8 mM) when it was pre-incubated with H2O2 100 µM, whereas NP islets returned to baseline levels when pre-incubated with H2O2 300 ?M. When islets were pre-incubated with NAC 10 mM + H2O2 150 µM and further incubated with glucose 33 mM, insulin secretion was reduced in NP, whereas in LP it was increased. Taken together, these datasuggest that pancreatic islets from undernourished rats when pre-treated with H2O2 and thereafter challenged with high glucose concentrations are more sensitive to H2O2, probably due to their lower capacity to detoxify reactive oxygen species (ROS). / Mestrado / Fisiologia / Mestre em Biologia Funcional e Molecular
434

Influência do pH de géis clareadores e do tempo de aplicação em esmalte pré dessensibilizado na topografia e cor dental / Influence of the pH of bleaching gels and the time of application in pre desensitized enamel on topography and dental color

Mendes, Gustavo Adolfo Martins 29 February 2016 (has links)
Submitted by Franciele Moreira (francielemoreyra@gmail.com) on 2017-09-22T19:18:39Z No. of bitstreams: 2 Dissertação -Gustavo Adolfo Martins Mendes - 2016.pdf: 2835645 bytes, checksum: c9a699042102d4d37216711d64f67736 (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) / Approved for entry into archive by Luciana Ferreira (lucgeral@gmail.com) on 2017-09-25T11:44:57Z (GMT) No. of bitstreams: 2 Dissertação -Gustavo Adolfo Martins Mendes - 2016.pdf: 2835645 bytes, checksum: c9a699042102d4d37216711d64f67736 (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) / Made available in DSpace on 2017-09-25T11:44:57Z (GMT). No. of bitstreams: 2 Dissertação -Gustavo Adolfo Martins Mendes - 2016.pdf: 2835645 bytes, checksum: c9a699042102d4d37216711d64f67736 (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Previous issue date: 2016-02-29 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES / Tooth bleaching is one of the procedures with the greatest increase in demand, and the number of products and publications in recent years. However, regardless of the technique to be used bleaching, bleaching agents can cause various changes in tooth structure. Some whitening agents have a pH drop over its response action, which can cause changes in the mineral content of the enamel. These changes may be higher when the time of contact between the bleaching agent and the tooth surface is increased. The aim of this study was to investigate the influence of time of application of whitening gel and its effects on tooth structure in pre-desensitized enamel samples with arginine bicarbonate. Eighty enamel blocks (5.5 x 5.5 mm) were obtained from 40 third molar teeth. These were randomly divided into 16 experimental groups (n = 5). Samples were pre-desensitized with arginine bicarbonate (Colgate Pro-Relief) and then bleached as experimental groups, varying the method of application of whitening gels (Opalescence Boost - Ultradent; Total Blanc - DFL) versus time. The pH range of the gel over the application time, the color variation obtained and roughness of the sample surface were evaluated. Results were subjected to statistical analysis with a significance level of 5%, showed similarity between the gels as the bleaching efficiency and roughness standards and longer application times tend to generate higher roughness values. It was concluded that shorter times of application of the whitening gel are more efficient since they cause less damage to enamel and are able to lighten equally and that the use of desensitizing toothpaste Arginine bicarbonate base prior to bleaching does not affect the whitening effect. / O clareamento dental é um dos procedimentos com o maior aumento de procura, além do número de produtos e publicações nos últimos anos. No entanto, independentemente da técnica clareadora a ser utilizada, os agentes clareadores podem provocar várias alterações na estrutura dental. Alguns agentes de clareamento tem uma queda do pH ao longo da sua reação de ação, o que pode provocar alterações no conteúdo mineral do esmalte. Estas mudanças podem ser mais elevadas quando o tempo de contato entre o agente clareador e a superfície do dente é aumentado. O objetivo desse trabalho foi verificar a influência do tempo de aplicação do gel clareador e seus efeitos sobre a estrutura dental em amostras de esmalte pré-dessensibilizados com Bicarbonato de Arginina. Oitenta blocos de esmalte dental (5,5 x 5,5 mm) foram obtidos a partir de 40 dentes terceiros molares. Estes foram divididos aleatoriamente em 16 grupos experimentais (n=5). As amostras foram pré-dessensibilizadas com Bicarbonato de Arginina (Colgate Pró-Alívio) e em seguida clareadas conforme os grupos experimentais, variando o método de aplicação de géis clareadores (Opalescence Boost – Ultradent; Total Blanc – DFL) em função do tempo. A variação de pH do gel ao longo dos tempos de aplicação, a variação de cor obtida e rugosidade da superfície das amostras foram avaliados. Resultados foram submetidos a análise estatística com nível de significância em 5%, revelaram semelhança entre os géis quanto a eficácia clareadora e padrões de rugosidade e que tempos de aplicação mais longos tendem a gerar maiores valores de rugosidade. Concluiu-se que tempos de aplicação mais curtos do gel clareador são mais eficientes uma vez que geram menos danos ao esmalte e são capazes de clarear de igual forma e que o uso de creme dental dessensibilizante a base de Bicarbonato de Arginina previamente ao clareamento não altera o efeito clareador.
435

Uso de eletrodos de cobre e eletrodos modificados como sensores eletroquímicos / Use of copper and modified electrodes as electrochemical sensors

Luiza Maria Ferreira Dantas 28 November 2014 (has links)
Este trabalho foi dividido em quatro etapas, além da introdução. A primeira parte consiste no estudo comparativo do comportamento eletroquímico de eletrodos de cobre em soluções tampão fosfato 0,10 mol L-1 com valores de pH 4,5 e 7,8, e em solução de NaOH com valores de pH 13,0 e 14,0. Mostrou-se que as espécies formadas eletroquimicamente sobre a superfície do eletrodo são dependentes do valor de pH e do potencial aplicado. Os resultados experimentais obtidos estão de acordo com aqueles reportados na literatura. A segunda parte da tese corresponde ao desenvolvimento de um sensor eletroquímico fabricado com microeletrodos de cobre para a determinação de peróxido de hidrogênio (H2O2) em amostras comerciais de antissépticos bucais e clareadores dentais. Nas condições experimentais otimizadas (solução tampão fosfato 0,10 mol L-1 (pH 7,0) e potencial de redução de -0,20 V), microeletrodos de cobre foram utilizados para a determinação de H2O2 sem a necessidade de etapas de extração, obtendo-se faixa linear de 0,015 a 6,4 mmol L-1 e limite de detecção de 2,8 &#181;mol L-1. O método proposto mostrou-se reprodutível e a presença de interferentes na matriz da amostra analisada não alterou a resposta do sensor para H2O2. Na terceira parte, a reação de eletro-oxidação de glicerol em superfícies de cobre em soluções de NaOH foi investigada utilizando a microscopia eletroquímica de varredura (SECM) no modo de geração pelo substrato de cobre / coleta no microeletrodo de platina (tip) (SG/TC). Os experimentos com a SECM mostraram a dependência da corrente com a distância entre o gerador e a tip, assim como a dependência com a concentração da solução de NaOH. Além disso, a corrente monitorada no microeletrodo diminuiu significativamente após a adição de glicerol. A atividade eletrocatalítica de eletrodos de cobre, no que diz respeito à oxidação de glicerol em meio alcalino, permitiu o desenvolvimento de um sensor amperométrico para a determinação de glicerol em amostra de biodiesel, com um intervalo linear de 0,05 a 1,33 mmol L-1 e limite de detecção de 20 &#181;mol L-1. A metodologia proposta foi aplicada para a determinação do analito em uma amostra de biodiesel de mamona. A quarta parte descreve a síntese, caracterização eletroquímica e utilização de nanotubos de carbono de paredes múltiplas (NCPM) decorados com nanopartículas de paládio (Pd) para a modificação da superfície de eletrodo de carbono vítreo (CV) para a oxidação de metanol, etanol e glicerol em solução de KOH 1,0 mol L-1. Os resultados mostraram que o NCPM/Pd é um bom catalisador para a eletro-oxidação de álcoois em meio alcalino e que maior atividade eletrocatalítica foi obtida para o glicerol. Em condições otimizadas, experimentos amperométricos foram realizados para o desenvolvimento do método analítico para a determinação de glicerol em biodiesel, obtendo-se um intervalo linear de 0,06 a 24 mmol L-1 e limite de detecção 30 &#181;mol L-1. Amostras de biodiesel foram analisadas com sucesso por meio de curvas de adição de padrão utilizando o eletrodo CV/NCPM/Pd. / This thesis is divided into four parts, apart from a general introduction. Part 1 is concerned with a critical comparison of the electrochemical behaviour of copper electrodes, in 0.10 mol L-1 phosphate buffer solution (pH 4.5 and 7.8), and in NaOH solution (pH 13.0 and 14.0). The electrochemical study showed that the species formed on the surface depends on both pH and the applied potential. The experimental results are in good agreement with those reported in the literature. A second goal of the thesis was the development of an electrochemical sensor for hydrogen peroxide (H2O2) determination in commercial oral antiseptic and dental whitening samples using copper microelectrodes. With optimized experimental conditions (working potential applied = -0.20 V in 0.10 mol L-1 phosphate buffer solution pH= 7.0), copper microelectrodes can be used to detect H2O2 without any previous extraction steps, in the range of 0.015 to 6.4 mmol L-1 with a lower detection limit of 2.8 &#181;mol L-1. In addition, the electrode exhibited an excellent reproducibility and long-term stability as well as negligible interference from sorbitol, ethanol, glycerin and saccharin. In the third part, the electrooxidation reaction of glycerol at copper surfaces in NaOH solutions was investigated using Scanning Electrochemical Microscopy (SECM) in a copper substrate generation / platinum microelectrode (tip) collection mode (SG/TC). The results showed the dependence of the current measured at the tip with respect to the distance between generator and the tip, as well as on the concentration of the NaOH solution. Other studies led to the conclusion that the current measured at the tip decreased significantly after addition of glycerol in the solution. The electrocatalytic activity of copper electrodes for the oxidation of glycerol in alkaline medium allowed the development of an amperometric method to determine glycerol in biodiesel samples in the range 0.05 to 1.33 mmol L-1 with a detection limit of 20 &#181;mol L-1. The determination of the analyte in a castor biodiesel sample employing a single copper microelectrode was carried out. The four part of this thesis shows results on the synthesis, electrochemical characterization and use of a glassy carbon (GC) electrode modified with multi-wall carbon nanotubes (MWCNT) decorated with palladium (Pd) for the electrochemical oxidation of methanol, ethanol and glycerol in 1.0 mol L-1 KOH solution. The results showed that MWCNT/Pd is a good electrocatalyst for methanol, ethanol and glycerol oxidation in alkaline medium, with highest activity toward glycerol oxidation. With optimized experimental conditions, an amperometric method was developed for the determination of glycerol in biodiesel samples, in the range of 0.06 to 24 mmol L-1 and detection limit of 30 &#181;mol L-1. Biodiesel samples were successfully analyzed by the standard addition method using the GC/MWCNT/Pd film electrode.
436

Associação de dois analgésicos não evita a sensibilidade causada pelo clareamento dental de consultório: ensaio clínico randomizado, triplo cego. / Combination of two analgesics does not avoid bleaching-induced tooth sensitivity: a randomized, triple-blind clinical trial.

Alpini, Camila Basso 16 March 2018 (has links)
Submitted by Edineia Teixeira (edineia.teixeira@unioeste.br) on 2018-10-08T16:27:39Z No. of bitstreams: 2 Camila_Alpini_2018.pdf: 897809 bytes, checksum: 188fdf141d2f5b2e51f5b8c3bcaf2bad (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) / Made available in DSpace on 2018-10-08T16:27:39Z (GMT). No. of bitstreams: 2 Camila_Alpini_2018.pdf: 897809 bytes, checksum: 188fdf141d2f5b2e51f5b8c3bcaf2bad (MD5) license_rdf: 0 bytes, checksum: d41d8cd98f00b204e9800998ecf8427e (MD5) Previous issue date: 2018-03-16 / Background: Administrating intraoral drugs alone was not able to reduce the TS after bleaching; the objective of this study was to determine if an association of two drugs could induce analgesia at a higher level. Methods: A triple-blind, parallel-randomized clinical trial was conducted with 115 patients receiving either an association of ketorolac tromethamine 10mg /acetaminophen 750mg or a placebo. The first dose was administered 1h before the in-office bleaching, and extra doses every 8h for 48h. The TS was recorded on VAS (0-10) and NRS (0-4) scales, during bleaching and1-6h, 12-18h, 18-24h, 24-48h post-bleaching. The color was measured before and one month after dental bleaching using two visual shade guide and spectrophotometer. The absolute risk of TS was evaluated by Chi-square test. The TS intensity for both scales were compared with ANOVA tests and Mann-Whitney U test. Comparisons between times within each group were performed by the Friedman test. The color changes between groups were compared by the Student t-test (α = 0.05). Results: No significant differences in the absolute risk of TS and color between the groups (p > 0.05), however the intensity of TS decreased in the experimental group for the periods 12 to 24h (p > 0.04) and 24 to 48 h (p > 0.03). Conclusion: The ketorolac tromethamine/acetaminophen association prior to in-office bleaching does not reduce the risk, but reduce the intensity of TS after 12h. Practical Implications: Using two analgesics was capable to prevent TS arising from in-office dental bleaching after 12h. / Introdução: A administração de drogas intra-orais isoladamente não foi capaz de reduzir a SD após o clareamento, o objetivo deste estudo foi determinar se associação de duas drogas pode induzir a analgesia a um nível mais elevado. Metodologia: Um ensaio clínico randomizado, paralelo, triplo-cego foi conduzido com 115 pacientes, os quais receberam uma associação de cetorolaco de trometamina 10mg e paracetamol 750mg ou placebo. A primeira dose administrada 1h antes do clareamento e as doses extras a cada 8h durante 48 h. A SD foi registrada nas escalas: VAS (0-10) e NRS (0-4) em diferentes períodos: durante o clareamento até 1h, 6h, 12h, 24h e 48h pós-clareamento. A cor foi registrada inicialmente e 1 mês após o clareamento, com as escalas visuais e um espectrofotômetro. O risco absoluto foi avaliado pelo teste Qui-quadrado. A intensidade de sensibilidade para ambas as escalas foi realizada pelo teste de ANOVA e Mann-Whitney. Comparações entre os tempos, dentro de cada grupo, foram realizadas pelo teste de Friedman. As alterações de cor entre os grupos foram comparadas pelo teste t de Student (α=0.05). Resultados: Não foram observadas diferenças estatisticamente significantes entre os grupos para o risco de SD e cor, porém intensidade da SD no grupo experimental diminuiu no período de 12 a 24h (p > 0.04) e 24 a 48 h (p > 0.03) após o clareamento (p > 0.05). Conclusão: A associação de paracetamol e toragesic não reduz a prevalência de SD, mas reduz a intensidade de SD após 12h do clareamento de consultório. Relevância clínica: O uso de dois analgésicos foi capaz de diminuir a intensidade de SD decorrente do clareamento de consultório após 12 horas do mesmo.
437

Decomposição do peróxido de hidrogênio sobre catalisadores de paládio / Hydrogen peroxide decomposition over palladium catalysts

Voll, Fernando Augusto Pedersen 14 February 2008 (has links)
Made available in DSpace on 2017-07-10T18:08:08Z (GMT). No. of bitstreams: 1 Fernando A P Voll.pdf: 745866 bytes, checksum: 24554e9ffb768c3450aabbf525840c64 (MD5) Previous issue date: 2008-02-14 / Fundação Araucária / Hydrogen peroxide decomposition is an undesirable reaction in the direct H2O2 synthesis process from H2 and O2. It s a desirable reaction for the generation of hydroxyl radicals (-OH) in the advanced oxidation processes. Thus, it is important to understand how the reaction medium conditions affect the H2O2 decomposition. In this work, the influence of the initial concentration of H2O2, the reaction temperature, the catalyst treatment with H2 and the catalyst deactivation (or activation) with H2O2 were studied. The catalysts studied in this work were a 5% Pd/C, a 0,5% Pd/C, a 1% Pd/g-Al2O3, and a 1% Pd/ZrO2. With the exception of the 1% Pd/ZrO2 catalyst, the apparent reaction rate constant (k) was affected by the initial concentration of H2O2 in the reaction medium, and in all cases where the reaction rate constant (k) was affected, its value decreased with the increase of the initial concentration of H2O2. The activation energy value was calculated for all the catalysts and varied between 25 and 55 kJ/mol. For all the catalysts tested, treatment with hydrogen resulted in a significant increase in the apparent reaction rate constant (k), and in a decrease in the activation energy for the reaction. All the reactions were well represented by a first order rate law. The effect of the treatment with H2O2 (realization of successive reactions of H2O2 decomposition, without catalyst exchange) was studied for the 5% Pd/C and 0,5% Pd/C catalysts (exposed to H2 or not). A small deactivation was observed in the 5% Pd/C catalyst (without prior exposure to H2) after four H2O2 decomposition reactions. A more significant deactivation was observed for the 5% Pd/C and 0,5% Pd/C (both treated with H2). For the 0,5% Pd/C catalyst not exposed to hydrogen, an activation of the catalyst occurred after successive reactions of H2O2 decomposition. / A decomposição do peróxido de hidrogênio é uma reação indesejável no processo de síntese direta do H2O2 a partir do H2 e O2. Por outro lado, é uma reação desejável para a formação dos radicais hidroxila (-OH) nos processos oxidativos avançados. Assim, é importante entender como as condições do meio de reação afetam a decomposição do H2O2. Neste estudo, foi verificada a influência de alguns fatores, tais como a concentração inicial de H2O2, a temperatura de reação, o tratamento do catalisador com H2 e a desativação (ou ativação) do catalisador com H2O2. Os catalisadores estudados nesse trabalho foram 5% Pd/C, 0,5% Pd/C, 1% Pd/&#947; -Al2O3 e 1% Pd/ZrO2. Com exceção do catalisador 1% Pd/ZrO2, a constante de velocidade aparente (k) da reação foi influenciada pela concentração inicial de H2O2 no meio reacional, e em todos os casos onde a constante de velocidade (k) foi afetada, seu valor diminuiu com o aumento da concentração inicial de H2O2. O valor da energia de ativação foi calculado para todos os catalisadores e variou entre 25 e 55 kJ/mol. Para todos os catalisadores testados, o tratamento com hidrogênio resultou em um aumento significativo no valor da constante de velocidade aparente (k), e em uma diminuição do valor da energia de ativação da reação. Todas as reações foram bem representadas por uma lei de velocidade de primeira ordem. O efeito do tratamento com H2O2 (realização de consecutivas reações de decomposição de H2O2, sem a troca do catalisador) foi verificado nos catalisadores 5% Pd/C e 0,5% Pd/C (tratados com H2 e não tratados). Uma pequena desativação foi observada no catalisador 5% Pd/C (não tratado) depois de algumas reações de decomposição do H2O2. Uma desativação mais significativa foi observada nos catalisadores 5% Pd/C e 0,5% Pd/C (ambos tratados com H2). Para o catalisador 0,5% Pd/C (não tratado com H2), ocorreu uma ativação do catalisador depois de sucessivas reações de decomposição do H2O2.
438

Estudo da esterilização por plasma de acoplamento indutivo e análise comparativa com esterilização por óxido de etileno / Study of sterilization by Inductively coupled plasma and comparison with sterilization by ethilene oxyde

Michelle Rigamonti Boscariol 10 August 2006 (has links)
Em âmbito hospitalar é crescente o emprego de dispositivos confeccionados de distintos materiais termossensíveis. Assim, o emprego de metodologias esterilizantes compatíveis tem sido o foco de muitas pesquisas, dentre as quais destacam-se estudos envolvendo o plasma. O mecanismo de ação deste desenvolve-se com a aplicação de Rádio-Freqüência a gases precursores, resultando na inativação microbiana por espécies altamente reativas. Este método inovador caracteriza-se por não gerar riscos de toxicidade ocupacional e aos pacientes, e ser processado em temperatura próxima ao ambiente. Para análise comparativa foi utilizado o método de esterilização por óxido de etileno (agente químico na forma gasosa). Este gás apresenta características de elevada inflamabilidade, explosividade e toxicidade, por isso é usado diluído em gases inertes, além de deixar residual no material esterilizado, tendo que ter um controle rigoroso no processo de aeração; porém atualmente é um dos métodos mais utilizados para esterilização de materiais odonto-médico-hospitalares, particularmente os termossensíveis. O principal objetivo deste trabalho foi estudar diferentes parâmetros do processo e seus respectivos resultados, que influenciam na esterilização empregando plasma e compará-los com os obtidos empregando óxido de etileno. O equipamento utilizado para o estudo dos processos de esterilização por plasma foi o ICP (Inductively Coupled Plasma). Analisou-se assim para o plasma algumas distintas combinações de parâmetros, tais como: gases (oxigênio puro e mistura deste com peróxido de hidrogênio a 5,10 e 20%), pressão (330 mTor), vazão do gás (100sccm), temperatura (próxima ao ambiente), potência de rádio-freqüência (300, 350 e 400W), tempos de exposição (com intervalos de 3 a 60 min) e umidade relativa (80±5%). No ICP foram desenvolvidas duas fases planejadas para os processos, seguindo uma programação experimental, já no óxido de etileno foram realizadas três séries de exposições sub–letais utilizando mistura esterilizante Oxyfume® 2002 (10% Óxido de Etileno, 63% HCFC 124 e 27% HCFC 22), sendo os parâmetros padronizados: umidade relativa (40 a 60%), concentração do gás (450 mg/L), temperatura (55° C) e tempos de exposição (com intervalos de 3 a 15 min.). Todos os ciclos foram realizados em triplicata. Esporos de Bacillus subtilis var. niger ATCC 9372 foram obtidos a partir de suspensões de microrganismos e inoculados em suportes na concentração de 107 UFC/suporte para serem utilizados nos estudos dos processos de esterilização. Empregou-se a técnica de Pour Plate (incubação em estufa por 24hs a 37 °C) para a quantificação dos esporos. Para o processo de esterilização por plasma os resultados obtidos forneceram valores D que variaram entre 8 e 3 min., dependendo dos parâmetros testados, e para o processo de esterilização por óxido de etileno o Valor D foi de 2,80 min. Concluiu-se que o processo de esterilização por plasma apresentou resultados interessantes e promissores e os melhores resultados foram obtidos com as potências maiores de 350 e 400W para o gás oxigênio puro, caracterizando o plasma como alternativa promissora de esterilização, devido às suas características positivas frente ao óxido de etileno, pois os valores D entre os dois processos de esterilização não apresentaram uma diferença significativa. / The gas Plasma sterilization technology has been emerging as an alternative to conventional low temperature processes since the advent of new therapies using heat sensitive materials in the healthcare field is greater than ever. The gas Plasma mechanism of action includes the generation of actives species by an electrical discharge, which is able to promote lethal effect on microorganisms. The sterilization techniques using gas plasma are under intense investigation and it has already been demonstrated by recent studies that this technology is simple, cost-effective, suitable for microbicidal activity and absent of toxic residuals. Ethylene oxide is the sterilization agent most widely applied to medical devices. However, its explosiveness, inflammability and toxicity led to the search for other sterilization methods at low temperature and it has been used associated to non active gases which inhibit these properties and it is necessary to have the control at the occupational safety and environmental monitoration. Therefore, the aim of this work was to explore possible microbicidal application of the gas plasma sterilization generated by an inductively coupled system and to compare this sterilization method with ethylene oxide (chemistry substance in gaseous form), observing their D value. It was used distinct combinations of process parameters to sterilization by plasma, as follows: radio-frequency powers (300, 350 and 400 watts), exposition times (in the range of 3 to 60 minutes), gas (pure oxygen and mixture with hydrogen peroxide 5,10 and 20%), gas flow (100 sccm), pressure (330 mTorr), temperature (close to the environmental one) and relative humidity 80±5%. For ethylene oxide, Oxyfume 2002® was used (mixture of ethylene oxide, HCFCs 22 and 124), under the concentration of 450mg/L, at the temperature of 55°C and relative humidity of 50±5% and it was submitted to a time of exposition between 3 to 15 minutes. Both processes were submitted to exposition cycles in triple. Bacillus subtilis var. niger ATCC 9372 inoculated in a standard load of 107 spores per carrier was used as biological indicator. After the exposition, the biological indicator\'s spore survivors were counted by the \"Pour Plate\" technique (incubation temperature of 35 ± 2ºC for 24 hours). Significant microbial reduction was observed in some cases where the plasma D value was between 3 and 8 min and 3,08 min, 3,04 min. to 350 and 400W powers respectively. In the ethylene oxide process the D value was 2,80 min. These results evidenced the higher effectiveness of ethylene oxide comparatively to plasma. However the latter presents advantages that make it an interesting alternative to low temperature sterilization processes.
439

Influência da pré-oxidação com ozônio e peróxido de hidrogênio na remoção de atrazina em filtros lentos de areia e carvão ativado granular / Effects of pre-oxidation with ozone and ozone associated to hydrogen peroxide in removing atrazine in slow sand filtration and granular activated carbon filtration

Edumar Ramos Cabral Coelho 04 October 2002 (has links)
O interesse na remoção de material orgânico no tratamento de águas de abastecimento surgiu em decorrência do aumento na poluição dos mananciais, da descoberta de novas doenças de veiculação hídrica e do melhor conhecimento das propriedades mutagênicas e carcinogênicas de poluentes orgânicos, entre eles os agroquímicos. Na presente pesquisa foi estudada a seqüência de processos de tratamento: pré-filtração; pré-oxidação com ozônio e ozônio associado ao peróxido de hidrogênio e filtração lenta com leito de areia e leito de carvão ativado granular. Para concentração de atrazina no afluente entre 2,2 e 110,3 µg/L o filtro lento de areia com camada intermediária de carvão ativado granular apresentou para a condição de não utilização de pré-oxidação valores para atrazina no efluente inferiores a 2,0 µg/L e para dose de ozônio entre 0,9 e 3,7 mg/L e para relação de peróxido de hidrogênio entre 0,1 e 1,1 valores para atrazina inferiores a 0,1 µg/L. O sistema de tratamento com pré-filtração, pré-oxidação com ozônio e ozônio associado ao peróxido de hidrogênio seguido da filtração lenta com camada intermediária de carvão ativado granular, mostrou-se eficiente na remoção de atrazina para concentrações inferiores a 0,1 µg/L. / The interest in removing organic matter in supplying waters treatment processes emerged from the increasing levels of water pollution worldwide, the discovery of new water-born diseases and of a better knowledge of mutating (mutagenic) and carcinogenic features of organic pollutants, including the pesticides. The two sequential arrangements for the water treatment process considered in this research were: 1) pre-filtration, slow sand filtration and granular activated carbon filtration; and 2) pre-filtration, pre-oxidation with ozone and ozone associated to hydrogen peroxide, slow sand filtration and granular activated carbon filtration. For concentrations of atrazine between 2.2 and 110.3 µg/L in the affluent, its concentration in the effluent was lower than 2.0 µg/L for the first arrangement, and lower than 01 µg/L for the second one, in this case for consumed doses of ozone between 0.9 and 3.7 mg/L and ratio H2O2/O3 between 0.1 and 1.1. The treatment system used composed of pre-filtration, pre-oxidation with ozone and ozone associated to hydrogen peroxide followed by the slow filtration, with an intermediate layer of granular activated carbon, was found efficient in reducing atrazine to levels inferior to 0.1 µg/L.
440

Influência da pré-oxidação com ozônio e peróxido de hidrogênio no desempenho da filtração lenta em areia e carvão ativado granular / The influence of pre-oxidation with ozone and hydrogen peroxide on the performance of slow filtration with filtering medium of sand and activated granular carbon

Nora Katia Saavedra del Aguila 06 September 2002 (has links)
A pesquisa apresenta a influência da pré-oxidação com ozônio, peróxido de hidrogênio e com ozônio associado ao peróxido de hidrogênio no desempenho da filtração lenta com meio filtrante de areia e carvão ativado granular, procedida por duas unidades de pré-tratamento em série, a pré-filtração dinâmica e a pré-filtração vertical ascendente. A unidade de filtração lenta foi bem operada com taxa de 3 m3/m 2.d, tendo sido realizadas seis carreiras de filtração. A eficiência da unidade foi avaliada em função de medições de cor, absorvância a 254 nm, carbono orgânico dissolvido, coliformes fecais, algas protozoários e metazoários. Na camada biológica predominaram as Classes Chlorophyceae, Bacillariophyceae sobre as Chrysophyceae, Cyanophyceae e Euglenophyceae. A aplicação de ozônio, peróxido de hidrogênio e ozônio associado ao peróxido de hidrogênio, afetou a maturação da camada biológica em relação à diversidade de espécies e densidade populacional de algas. As algas que colonizaram o meio filtrante, ao longo de sua profundidade, foram espécies das Classes Chlorophyceae e Bacillariophyceae. O meio filtrante apresentou, também, colonização de protozoários e rotíferos. Houve diferenças significativas na qualidade do efluente do filtro lento com relação à remoção de turbidez, cor verdadeira, cor aparente, absorvância a 254 nm e carbono orgânico dissolvido nas diferentes carreiras de filtração decorrente do uso de pré-oxidantes; o que não foi observado com relação à remoção de bactérias heterotróficas, coliformes totais e fecais. / This dissertation presents the influence of pre-oxidation with ozone, hydrogen, peroxide and ozone associated with hydrogen peroxide on the performance of slow filtration with filtering medium of sand and actived granular carbon, preceded by two pretreatment units in series, i.e., dynamic and vertical downflow prefilters. Six runs of slow filtration units were operated with a rate of 3 m3/m2.d each. The efficiency of the filtering unit was evaluated by colour determination, absorbance at 254 nm, dissolved organic carbon, total coliforms, fecal coliforms, algae, protozoa and metazoa. Chlorophyceae and Bacilllariophyceae classes predominated over Chrysophyceae, Cryptophyceae, Cyanophyeeae and Euglenophyeeae classes in the schmutzdecke. The application of ozone, hydrogen peroxide and ozone associated with hydrogen peroxide affected the schmutzdecke maturation in relation to the species diversity and population density of algae. The algae that developed in the filtering medium along its depth were species of the Chlorophyceae and Bacillariophyceae classes. The filtering medium also presented a development of protozoa and rotifers. There were significam differences in the quality of slow filter effluent in relation to turbidity removal, true colour, apparent colour, absorbance at 254 nm and dissolved organic carbon in the different filtration runs caused by the use of pre-oxidants. Such differences were not observed in the removal of heterotrophic bacteria and, total and fecal coliforms.

Page generated in 0.044 seconds