• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 403
  • 222
  • 66
  • 28
  • 16
  • 13
  • 9
  • 7
  • 7
  • 6
  • 6
  • 6
  • 5
  • 5
  • 4
  • Tagged with
  • 961
  • 298
  • 220
  • 210
  • 191
  • 181
  • 159
  • 106
  • 70
  • 70
  • 69
  • 61
  • 59
  • 56
  • 54
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
331

Direct determination of lead in airborne particulate matter by graphite furnace atomic absorption spectrometry.

January 1997 (has links)
by Lai Yuen Kwan. / Thesis (M.Phil.)--Chinese University of Hong Kong, 1997. / Includes bibliographical references (leaves 41-45). / Abstract --- p.i / Acknowledgement --- p.ii / Contents --- p.iii / List of Figures --- p.vi / List of Tables --- p.vii / Chapter 1. --- INTRODUCTION / Chapter 1.1 --- Air Pollution in Hong Kong --- p.1 / Chapter 1.2 --- Lead in Air and its Harmful Effects on Human --- p.3 / Chapter 1.3 --- Sampling of Air Particulates --- p.6 / Chapter 1.3.1 --- Principles of filter sampling --- p.6 / Chapter 1.3.2 --- Filter media for air sampling --- p.7 / Chapter 1.4 --- Sample Treatment --- p.9 / Chapter 1.4.1 --- Acid digestion - standard method for analysis of metals --- p.9 / Chapter 1.4.2 --- Slurry sampling - direct method for analysis of metals --- p.9 / Chapter 1.4.3 --- Literature survey on slurry sampling --- p.10 / Chapter 1.4.4 --- Comparison between acid digestion and slurry sampling methods --- p.10 / Chapter 1.5 --- Instrumental Analysis --- p.11 / Chapter 1.5.1 --- Graphite furnace atomic absorption spectrometry --- p.11 / Chapter 1.5.2 --- Background correction by the Zeeman effect --- p.12 / Chapter 2. --- EXPERIMENTAL / Chapter 2.1 --- Apparatus --- p.14 / Chapter 2.2 --- Reagents --- p.14 / Chapter 2.3 --- Procedure --- p.15 / Chapter 2.3.1 --- Selection of sample introduction technique --- p.15 / Chapter 2.3.2 --- Recovery study of lead in standard reference material (SRM) in 1-decanol --- p.16 / Chapter 2.3.3 --- Study of suspension behavior of solvents with SRM --- p.16 / Chapter 2.3.4 --- Recovery study of lead in SRM in ethylene glycol --- p.17 / Chapter 2.3.5 --- Determination of lead in SRM by the developed method --- p.17 / Chapter 2.3.6 --- Determination of lead in SRM by the acid digestion method --- p.18 / Chapter 2.3.7 --- Application of the developed method on the analysis of real sample --- p.18 / Chapter 3. --- RESULTS AND DISCUSSION / Chapter 3.1 --- Choice of Solvents for Suspension of Air Particulates --- p.20 / Chapter 3.2 --- Sample Introduction Technique --- p.20 / Chapter 3.3 --- Recovery Study of lead in SRM in 1-Decanol --- p.22 / Chapter 3.3.1 --- Drying stage of the temperature program for analysis --- p.23 / Chapter 3.3.2 --- Effect of 1-decanol on the absorbance signal of the analyte --- p.24 / Chapter 3.3.3 --- Sample injection volume --- p.25 / Chapter 3.3.4 --- Design of temperature program for analysis --- p.25 / Chapter 3.4 --- Study of Suspension Behavior of Solvents --- p.27 / Chapter 3.5 --- Recovery Study of lead in SRM in Ethylene Glycol --- p.32 / Chapter 3.6 --- Evaluation of the Developed Method --- p.33 / Chapter 3.6.1 --- Determination of lead in SRM --- p.33 / Chapter 3.6.2 --- Application of non-linear standard addition method --- p.35 / Chapter 3.6.3 --- precision and accuracy of the developed method --- p.36 / Chapter 3.7 --- Recovery Study with the Acid Digestion Method --- p.36 / Chapter 3.8 --- Analysis of Real Sample by the Developed Method --- p.37 / Chapter 3.8.1 --- Principles of TEOM® on mass measurement --- p.37 / Chapter 3.8.2 --- Selection of filter media for air sampling --- p.37 / Chapter 3.8.3 --- Study of dislodging efficiency of air particulates from Teflon filter --- p.38 / Chapter 3.8.4 --- Comparison with the acid digestion method --- p.39 / Chapter 4. --- CONCLUSION --- p.40 / Chapter 5. --- REFERENCES --- p.41 / Chapter 6. --- APPENDIX --- p.46
332

Avaliação de mutagenicidade, citotoxicidade e expressão de proteínas relacionadas a apoptose, Bak, BCL-2 e P53 fosforilado, em células tratadas com fuligem e particulado total de queima de cana-de-açúcar

Peron, Mariana Cristina Caloni [UNESP] 18 December 2006 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:30:55Z (GMT). No. of bitstreams: 0 Previous issue date: 2006-12-18Bitstream added on 2014-06-13T18:41:08Z : No. of bitstreams: 1 peron_mcc_dr_arafcf.pdf: 971260 bytes, checksum: b130fbae5d9dc40c7aae26eafe9d69b4 (MD5) / O etanol obtido da cana-de-açúcar tem sido considerado um combustível alternativo. Entretanto, em países em desenvolvimento, a colheita de cana é realizada manualmente depois da queima, sendo responsável pela emissão sazonal de poluentes atmosféricos. A mutagenicidade dos resíduos de queima de cana (RQCA) e as partículas presentes na ROFA (residual oil fly ash) foram observados nos ensaios de micronúcleo em células sanguíneas de camundongos e de células mãe de grão de pólen de Tradescantia pallida (TRAC-MCN) particulado. O estudo também verificou a citotoxicidade, apoptose e genotoxicidade nas células tratadas com extrato orgânico contendo grande quantidade de HPAs e suspensão na biomassa do período de safra e entressafra. Uma alta freqüência de MN foi observada no TSP do período de safra que na entressafra e a porcentagem de células mortas foi maior em células tratadas com extrato orgânico contendo grande quantidade de HPAs e particulado. Elevada expressão de Bcl-2 e baixa expressão de p53 fosforilado foi verificado em células tratadas com extrato orgânico contendo grande quantidade de HPAs no período de safra e entressafra e em 24 e 48h pós-tratamento. É possível concluir que os HPAs presentes no período de safra e entressafra são genotóxicos e citotóxicos. Políticas públicas deveriam ser discutidas para se buscar alternativas que diminuam a emissão desse poluente. / Ethanol obtained from sugar cane has been considered an alternative fuel. However, in developing countries, the handly harvesting is usually done after to sugar cane burning which is responsible for seasonal emission of air pollutants. The genotoxicity of sugar cane burning residues (SCBRs) and particle surrogates of residual oil fly ash (ROFA) were observed in micronuclei (MN) assay in mouse peripheral blood and bone marrow cells as well as in the pollen mother cells of Tradescantia pallida (TRAC-MCN). The study also verified cytotoxicity and genotoxicity of cells treated with polycyclic aromatic hydrocarbons (PAHs) and suspension, in harvesting and non-harvesting particulated biomass. Higher frequency of MN was observed in harvesting TSP than non-harvesting and the cell death was higher in cells treated with PHAs in both particulates. Bcl-2 overexpression of p53 phosphorylated low expression was verified in the cells treated with PHAs in harvesting and non-harvesting in 24 and 48 hours after treatment. We can conclude that PHAs presenting in harvesting time, which represents burning sugar cane biomass and non-harvesting time (fuel fossil combustion) are cytotoxic and genotoxic. Public politics should be discussed to found alternatives which could decrease air pollution emissions.
333

Tratamento de águas residuárias por alagados construídos de fluxo subsuperficial horizontal, utilizando Vetiver (Chrysopogon zizanoides L.) : avaliação e desempenho de três leitos distintos /

Dreifus, Thais von. January 2012 (has links)
Orientador: Eduardo Luiz de Oliveira / Banca: Giselda Passos Giafferis / Banca: Ilza Machado Kaiser / Resumo: Esta pesquisa visa o tratamento de águas residuárias através de Sistemas de Alagados Construídos (Westlands) de fluxo subsuperficial e escoamento horizontal. O principal objetivo deste sistema é a remoção da matéria orgânica, uma vez que, a matéria carbonácea presente no esgoto é degradada, tanto aerobicamente por microorganismos que estão aderidos nas raízes das mocrófitas quanto, anaerobicamente pelas bactérias aderidas no substrato do leito filtrante. A estação de tratamento de esgoto por Alagados Construídos está localizada na cidade de Bauru-SP e trata o esgoto produzido pela Moradia Estudantil e pelo Campus do Departamento de Educação Física da Universidade Estadual Paulista "Júlio de Mesquita Filho" (UNESP). Para uma melhor condição de estudo são utilizadoas três sistemas de leitos com 9m de comprimento por 4,5m de largura e 0,80m de profundidado e inclinação de 1%. Os leitos foram compostos por diferentes substratos: o primeiro, preenchido com brita nº 1, brita nº 3 e areia grossa, o segundo preenchido pedrisco, poliestireno expandido (isopor) moído e reciclado e areia grossa, e o terceiro com brita nº 3 e areia grossa. Com o uso desses diferentes substratos foi possível avaliar em duas etapas de análise, qual deles apresenta os melhores resultados e condições para o tratameto de águas residuárias. A eficiência média de remoção de DBO foi de 85,6% para o leito de brita, 84,2% para o leito de isopor e 85,4% para o leito de areia. A remoção de fosfato teve média de eficiência de 53,3% para o leito de brita, 9,6% para o leito de isopor e 89% para o leito de areia. Para o nitrogênio total Kjeldahl a eficiência média de remoção foi de 7,7% para o leito de brita, 77,0% para o leito de isopor e 75,3% para o leito de areia. No geral todo o sistema se mostrou eficiente para o tratamento de águas residuárias, porém o leito de isopor se destacar por se tratar de um material alternativo e reciclado / Abstract: This research aims at the wastewater treatment systems using constructed wetlands of subsurface flow and horizontal flow. The main objective of this system is the removal of organic matter, since the carbonaceous matter present in the sewage is dedraded, both aerobically by microorganisms which are adhered on the roots of macrophytes, anaerobically by bacteria adhered to the substrate of the filter bed. The sewage treatment plant by Constructed Westlands is located in the city of Bauru, SP, and treats the sewage produced by the student's home and Deparment of Physical Education, Universidade Estadual Paulista "Julio de Mesquita Filho" (UNESP). For a better quality studies are used three-bed systems with 9m long by 4.5m wide and 0.80m depth and inclination of 1%. The beds were made up of different substrates: the first, filled with gravel nº 1, nº3 crushed stone and sand, the second filled with gravel, expanded polystyrene (Stryrofoam) and recycled crushed and coarse sand, gravel and the third paragraph 3 and coarse sand. Using these substrates could be assessed in two stages of analysis, which one gives the best results and conditions for the treatment of wastewater. The average efficiency of BOD removal was 85.6% for the bed of crushed rock, 84.2% for the foam bed and 85.4% for the sand bed. The removal efficiency phosphate averaged 53.3% for the gravek bed, the bed to 9.6% of polystyrene and 89% for the sand bed. For the Kjeldahl nitrogen removal efficiency was an average of 75.7% for the bed of gravel, 77.0% for the bed of Styrodom and 75.3% for the sand bed. In general the whole system is efficient for the treatment of wastewater, byr the bed of Styrofoam stand out because it is an alternative material and recycled / Mestre
334

Health risk assessment of POPs and heavy metals in Hong Kong residents based on their concentrations in selected food items and different human tissues (blood plasma and adipose tissues)

Qin, Yanyan 01 January 2010 (has links)
No description available.
335

Método inovador de ativação de oxidantes no tratamento de poluentes prioritários e emergentes. / Innovative method of oxidants activation in the treatment of emerging and priority pollutants.

Celyna Káritas Oliveira da Silva 24 October 2014 (has links)
O presente trabalho trata do desenvolvimento um novo material, diatomita modificada por ferro, como ativador dos oxidantes persulfato de sódio e peróxido de hidrogênio para degradar poluentes prioritários (fenantreno e antraceno), diesel e o poluente emergente ácido perfluoroctanóico (PFOA). Os objetivos deste estudo foram comparar esse novo método com métodos convencionais de ativação para esses oxidantes; e estudar, estatisticamente, a relação ótima entre a quantidade deste material e a concentração de oxidante para a degradação dos contaminantes. A diatomita bruta e as diatomitas modificadas (CAT-5 e CAT-20) foram caracterizadas por diferentes técnicas. Os principais resultados da caracterização mostraram que os materiais são amorfos e que a concentração de ferro foi 4%, 17% e 25% para diatomita bruta, CAT-5 e CAT-20, respectivamente. Os resultados mostraram que os materiais modificados apresentaram significativa atividade catalítica para ativar os oxidantes e degradar os poluentes, sendo a CAT-5 a mais reativa. Resultados satisfatórios foram obtidos utilizando 45 g L-1 de persulfato de sódio com 2,5 g de diatomita modificada (CAT-5), com degradação de 87% e 96% de fenantreno e antraceno, respectivamente, em 168 horas de tratamento. Para o tratamento de solo arenoso contaminado com diesel, os melhores resultados foram obtidos utilizando 41 g L-1 de persulfato de sódio e 1,56 g de CAT-5, obtendo decaimento de 91% de carbono total em 146 horas. A eficiência da decomposição de PFOA mostra que a reatividade dos sistemas seguiu a ordem: peróxido de hidrogênio em altas concentrações > peróxido de hidrogênio em paralelo com persulfato > persulfato alcalino, ambos ativados com CAT-5, atingindo 86%, 69% e 48%, respectivamente, após 6 horas de reação. / The present work deals with the development of a new materials, modified diatomite by iron, as an activator of the oxidants sodium persulfate and hydrogen peroxide to degrade priority pollutants (phenantherene and anthracene), diesel and emerging pollutant perfluorooctanoic acid (PFOA). The aims of this study were to compare this new method with traditional activation method for these oxidants; and to study, statistically, the optimal ratio between the quantity of the material and the concentration of oxidant to the degradation of contaminants. The raw and modified materials were characterized by different techniques. The main characterization results showed that materials are amorphous, and that the iron concentrations were 4,78%, 17,65% and 25% for the raw diatomite, CAT-5 and CAT-20, respectively. The results showed that the modified material showed significant catalytic activity to activate the oxidants and to degrade pollutants, with CAT-5 being the most reactive. Satisfactory results were obtained using 2,5 g of modified diatomite (CAT-%) with sodium persulfate at 45 g L-1, with degradation of 87% and 96% of phenanthrene and anthracene, respectively, in 168 hours of treatment. For the treatment of sandy soil contaminated with diesel, the best result was obtained using 41 g L-1 of sodium persulfate sodium and 1,56 g of CAT-5, resulting in a decrease of 91% of total carbon present in diesel. The PFOA decomposition efficiency for the systems shows that hydrogen peroxide at high concentrations > hydrogen peroxide-activated persulfate > alkaline-activated persulfate, both with CAT-5, achieving 83%, 69% and 48% , respectively, after 6 hours of reaction.
336

Desenvolvimento e estudo de um sistema para tratamento de fenol e poluentes orgânicos emergentes (POE) por processos oxidativos avançados (POA) utilizando ozônio, peróxido de hidrogênio e radiação ultravioleta / Development and study of a system for the treatment of phenol and emerging organic pollutants (EOP) by advanced oxidation processes (AOP) using ozone, hydrogen peroxide and ultraviolet radiation

Felipe Rufine Nolasco 29 April 2014 (has links)
O estudo avaliou a efetividade de um sistema para tratamento de soluções aquosas contendo poluentes orgânicos emergentes (POE), denominados interferentes endócrinos (IE). Baseado nos processos oxidativos avançados (POA), empregando ozônio, radiação UV, peróxido de hidrogênio e variação de pH, o estudo possibilitou determinar a relação ideal oxidante/poluentes e o custo/benefício dos tratamentos com melhores desempenhos, de degradação do padrão contendo hormônios 17?-estradiol (E2) e 17?-etinilestradiol (EE2), e outra contendo atrazina (ATZ). Para os estudos, foi utilizado um planejamento fatorial 23, para identificar as melhores opções de degradação. Os tratamentos iniciaram com soluções em concentrações de 600 ?g L-1 de ATZ, em quadruplicatas, por períodos de até 10 minutos. Posteriormente a avaliação dos melhores tratamentos, foi estudada a cinética de mineralização de soluções a 5 mg L-1 de ATZ, em até 90 min. A concentração de estudo adotada para os hormônios foi de 1 mg L-1. A determinação da ATZ e dos hormônios (E2 e EE2) foi realizada por cromatografia em fase líquida (CLAE), utilizando a extração em fase sólida (EFS) quando necessário. Para o estudo foram construídos dois sistemas de tratamento paralelamente acoplados (S1 - escala laboratorial e S2 - escala piloto), com os respectivos volumes de 0,43 L e 20 L. O S2 possibilitou a avaliação da degradação e/ ou mineralização do fenol em solução a 50 mg L-1, porém em escala 60 vezes superior ao S1. As eficiências das mineralizações da ATZ e do fenol, foram avaliadas pela análise de Carbono Orgânico Total (COT). As condições experimentais pré-estabelecidas foram: (i) UV-C 254 nm, variando entre 0, 16 e 32 W; (ii) H2O2 entre 0, 50 e 100% do total teórico necessário para mineralização dos poluentes; (iii) O3 (4,6 g h-1) e (iv) pH 7; 9 e 11, previamente aplicadas às soluções estoque de ATZ. Após avaliação da melhor combinação para degradação, optou-se por trabalhar, nos demais estudos, apenas com soluções em pH 11,0. Na última etapa deste estudo, foram desenvolvidos dois métodos (direto e indireto) para avaliar a geração do gás ozônio em tempo real, possibilitando também realizar a medição do consumo de O3 durante os estudos. Para avaliar a eficiência dos métodos, os resultados analíticos foram convertidos em % de degradação ou mineralização e os custos dos tratamentos foram estimados. Comprovando a viabilidade desta proposta, resultados envolvendo o tratamento de solução padrão de atrazina (600 ?g L-1) apresentaram, nas melhores condições (pH 11, 30 mg L-1 de H2O2 e 4,6 g L-1 de O3), eficiência igual ou superior a 95% (<LQ) na degradação do herbicida, em apenas 2,5 minutos de tratamento e posteriormente soluções a 5 mg L-1, apresentando até 100% de mineralização em 90 minutos. Quanto aos hormônios foram obtidos poucos resultados acima do LD do equipamento, porém todos ficaram abaixo do LQ (50 ?g L-1). Quanto ao fenol (50 mg L-1), estudado no sistema piloto (S2), atingiu-se até 80% de mineralização em 24 horas e 100% de degradação. Os resultados obtidos demonstram que os sistemas apresentaram excelente eficácia conforme esperado / The study evaluated the effectiveness of a system for treatment of aqueous solutions containing emerging organic pollutants (EOP), called endocrine disruptors (ED). Based on advanced oxidation processes (AOP) using ozone, UV radiation, hydrogen peroxide and pH variation. This study allowed the determination of the ideal oxidant/pollutants ratio and the cost/benefit of treatments with better performance, regarding the degradation of the pattern containing hormones 17?-estradiol (E2) and 17?-ethinylestradiol (EE2), and another containing atrazine (ATZ). A 23 factorial design was used in the study to identify the best options for degradation. The treatments were started with solutions at concentrations of 600 ?g L-1 ATZ, in quadruplicate, for periods up to 10 min. Subsequently to the best treatment evaluation; the degradation of 5 mg L-1 ATZ solutions was evaluated, within 90 min. The adopted study concentration of the hormones was 0,05 mg L- 1 and 1,0 mg L- 1. The determination of the ATZ and hormones (E2 and EE2) was performed by liquid chromatography (HPLC) using solid phase extraction (SPE) when necessary. For this study, two parallel coupled processing systems were constructed (S1 - Laboratory scale and S2 - pilot scale) with the respective volumes of 0.43 L and 20 L. S2 system was developed to enable evaluation of the degradation of an already known substance, 50 mg L-1 phenol solution, but on a scale 60 times greater than S1. The efficiency of ATZ and phenol mineralization was evaluated by Total Organic Carbon (TOC). The pre-established experimental conditions were: (i) 254 nm UV-C, varying among 0, 16 and 32 W, (ii) H2O2 among 0, 50 and 100% of the theoretical value needed to complete mineralization of the pollutant, (iii) O3 (4,6 g h-1) and (iv) pH 7; 9 and 11 previously applied to all stock solutions. After assessing the best combination for degradation, it was chosen to work in the other experiments only solutions with pH 11.0. In the last stage of the study, two methods (an electric and a spectrophotometric) were developed to assess the ozone gas generation in real time and also allowing the measurement of O3 consumption during the studies. To evaluate the efficiency of the methods, analytical results were converted to % degradation or mineralization and treatment costs were estimated. Proving the feasibility of this proposal, preliminary results involving the treatment of atrazine standard solution (600 ?g L-1) had, in the best conditions (pH 11, 30 mg L-1 of H2O2 and 4,6 g L-1 of O3), efficiency equal or superior to 95% (<LQ) in degradation of the herbicide in just 2.5 minutes of treatment and then 5 mg L-1 solutions had 100% mineralization in 90 minutes. To hormones, few results above the DL of the equipment were obtained, but all were below the QL of the equipment (50 mg L-1). When phenol (50 mg L-1) was studied in the pilot system it reached up to 80% of mineralization within 24 hours. The obtained results shown that the systems developed reached high efficiency for treating the pollutants
337

Influência do posicionamento dos dutos de admissão de um cabeçote fundido e usinado no resultado swirl. / Influence of the intake ports positioning of cast and machined cylinder head on the swirl result.

Ewerton Correa dos Reis Xavier 17 August 2017 (has links)
O objetivo deste trabalho é avaliar a influência sobre o número de swirl e desempenho do motor diesel a partir de cabeçotes fabricados com variação no posicionamento relativo dos dutos de admissão em duas direções perpendiculares. Inicialmente definiu-se que o valor a ser deslocado seria de 1 milímetro, e então para cada combinação entre os dutos de admissão curto e longo deveria ser fabricado um número mínimo de seis cabeçotes para posteriores ensaios em bancada com dinamômetro. Após a fundição fabricar as nove combinações definidas, sendo uma delas com os eixos em suas condições nominais, isto é, sem o deslocamento de um milímetro, obtiveram-se um total de 60 cabeçotes. Os cabeçotes foram então controlados em máquina tridimensional, usinados e montados todos os seus componentes e enviados para a medição do número de swirl em máquina desenvolvida especialmente para este teste. Para cada cabeçote mediu-se o número de swirl duas vezes, e em seguida cada uma das nove combinações foram ensaiadas no mesmo dinamômetro e avaliados os respectivos parâmetros: consumo específico de combustível, curva de torque e emissão de poluentes. Para cada combinação mediu-se a curva de torque duas vezes e mediu-se três vezes o ciclo de emissões com treze pontos (ESC). Nos resultados de swirl, três combinações apresentaram-se fora dos limites da tolerância, uma abaixo do mínimo da tolerância em 22,7% e as outras duas além do máximo da tolerância em respectivamente 18,2% e 17,8%. Nos resultados de dinamômetro, nenhuma combinação se apresentou fora dos limites estabelecidos para o modelo de motor ensaiado nos seguintes parâmetros: consumo específico de combustível, torque e emissões de CO, HC, MP e NOx. / The main purpose of this work is to evaluate the influence on the swirl number and the engine diesel performance based on cylinder heads produced with variation on relative positioning of inlet ports in two perpendicular directions. Firstly, it was defined that the value to be displaced would be 1 millimeter, and then for each combination between the short and the long inlet ports should be produced a minimum of six cylinder heads for further testing on the dynamometer. After the foundry production of the defined nine combinations, one of them having the axis in their nominal positions, i.e. without the displacement of 1 millimeter, a total of 60 cylinder heads were obtained. These cylinder heads were measured in a tridimensional machine, machined and all of their components were assembled and their swirl number were measured in the machine developed specially for this method. For each cylinder head the swirl number was measured twice and after that all nine combinations were performed at the same dynamometer and the following parameters were evaluated: fuel consumption, torque curve and pollutants emission. For each combination the torque curve was measured twice and the thirteen point\'s emissions cycle (ESC) was measured three times. Concerning the swirl results, three combinations ended up out of the tolerance limits, one of them as 22,7% below the minimum tolerance and the other two as 18,2% and 17,8% respectively over the maximum tolerance. Regarding the dynamometer results, no combination ended up out of defined tolerances for the kind of engine tested in the following parameters: fuel consumption specific, torque and emissions of CO, HC, PM and NOx.
338

Caracterização microbiológica, química e presença de poluentes orgânicos em amostras de lodo de esgoto de São Paulo / Microbiological and chemical characterization and presence of organic pollutants in sewage sludge samples from São Paulo

Altina Lacerda Nascimento 04 April 2016 (has links)
Objetivou-se com este trabalho avaliar o potencial agrícola do lodo de esgoto produzido no estado de São Paulo, bem como, verificar a possibilidade de interação entre a composição química e a abundância relativa de bactérias no lodo. Foram realizadas coletas de amostra de lodo de esgoto em 19 estações de tratamento de esgoto, em três épocas distintas. Nas amostras provenientes das três épocas foram determinados as concentrações dos 16 hidrocarbonetos policíclicos aromáticos (HPAs) listados como prioritários no monitoramento ambiental pela USEPA (acenafteno, acenaftileno, antraceno, benzo(a)antraceno, benzo(a)pireno, benzo(b)fluoranteno, benzo(ghi)perileno, benzo(k)fluoranteno, criseno, dibenzo(a,h)antraceno, fenantreno, fluoranteno, fluoreno, indeno(1,2,3-cd)pireno, naftaleno e pireno). Nas amostras da segunda época de coleta, além da presença de HPAs, determinou-se as concentrações de poluentes orgânicos emergentes (hormônios, produtos farmacêuticos e produtos de uso industrial), realizou-se a caracterização completa segundo a Resolução CONAMA 375/2006 (umidade, pH, N-Kjeldahl e inorgânico, carbono orgânico, cálcio, potássio, fósforo, magnésio, enxofre, boro, cobre, ferro, níquel, manganês, molibdênio, selênio, zinco, alumínio, arsênio, bário, cádmio, cromo, chumbo, mercúrio e sódio) e a caracterização da comunidade bacteriana através de metodologia independente de cultivo (sequenciamento illumina). Os macronutrientes em maiores concentrações no lodo de esgoto são: N > Ca > S > P > Mg > K. Os elementos inorgânicos Ni e Zn apresentaram concentração superior à máxima permitida para utilização agrícola pela resolução Conama 375/2006 em 1 e 3 amostras, respectivamente. A substância inorgânica que mais limita o enquadramento do lodo de esgoto como adubo orgânico (Instrução Normativa 27/2006) é o Hg. Os compostos benzilparabeno, bisfenol AF (BPAF), ácido perfluorooctanoico (PFOA) e tetrabromobisfenol A (TBBPA) não foram detectados. Por outro lado, cimetidina, metilparabeno, bisfenol A (BPA) e triclocarban foram detectados nas 19 amostras avaliadas. O composto presente em maior concentração é o triclocarban. As concentrações de hidrocarbonetos policíclicos aromáticos são baixas, de acordo com a norma Europeia. Os filos Proteobacteria e Bacteroidetes estão presentes em maior abundância relativa. Existe uma comunidade bacteriana núcleo nas estações de tratamento de esgoto do estado de São Paulo, composta por 81 gêneros, presentes nas 19 ETEs avaliadas, dos quais, os que estão em maior abundância relativa são Treponema, Clostridium, Propionibacterium, Syntrophus e Desulfobulbus. A elevação do pH a valores próximos de 12 reduz a diversidade microbiana. Considerando a abundância relativa e a composição química do lodo de esgoto, as estações podem ser agrupadas em três grupos distintos, sendo que um deles é influenciado principalmente pelos teores de Ca, Zn e Cu, o outro pelos teores de Fe e S e o terceiro grupo que foi influenciado pelos demais fatores avaliados. / The aim of this work was to evaluate the agricultural potential of sewage sludge produced in the São Paulo state - Brazil, as well as to verify the possibility of interaction between the chemical composition and sewage sludge bacterial abundance. Samples were collected from 19 wastewater treatment plants in three different periods. On the samples from the three times were determined the presence and concentrations of 16 polycyclic aromatic hydrocarbons (HPAs) that are listed as priorities in environmental monitoring by the USEPA (acenaphthene, acenaphthylene, anthracene, benzo (a) anthracene, benzo (a) pyrene, benzo (b) fluoranthene, benzo (ghi) perylene, benzo (k) fluoranthene, chrysene, dibenz (a, h) anthracene, phenanthrene, fluoranthene, fluorene, indeno (1,2,3-cd) pyrene, naphthalene and pyrene). On the samples of the second collect time, besides HPAs, were determined the concentrations of emerging organic pollutants (hormones, pharmaceuticals and industrial products). It was performed the complete characterization according to CONAMA 375/2006 (moisture, pH, Kjeldahl and inorganic Nitrogen, organic carbon, calcium, potassium, phosphorus, magnesium, sulfur, boron, copper, iron, nickel, manganese, molybdenum, selenium, zinc, aluminum, arsenic, barium, cadmium, chromium, lead, mercury and sodium); and characterization of bacterial communities through cultivation-independent methods (Illumina sequencing). Macronutrients in higher concentrations in sewage sludge are: N > Ca > S > P > Mg > K. The inorganic elements Ni and Zn showed up in higher concentration than the maximum allowable for agricultural use by CONAMA Resolution 375/2006, at 1 and 3 samples, respectively. The inorganic element that most limits sewage sludge usage as organic fertilizer (MAPA, 2006) is the Hg. The compounds benzylparaben, bisphenol AF (BPAF), perfluorooctanoic acid (PFOA) and tetrabromobisphenol A (TBBPA) were not detected. On the other hand, methylparaben, cimetidine, bisphenol A (BPA) and triclocarban were detected in all 19 samples. The compound present in highest concentration is triclocarban. The concentrations of polycyclic aromatic hydrocarbons are low, according to the European standard. Proteobacteria and Bacteroidetes phyla are present in greatest relative abundance. There is a bacterial core in the sewage sludge treatment plants of the São Paulo State, comprising 81 genera present in all WWTPs evaluated. Those who are at a higher relative abundance are Treponema, Clostridium, Propionibacterium, Syntrophus and Desulfobulbus. The elevation of pH to values close to 12 reduces the microbial diversity. Considering the relative abundance and chemical composition of sewage sludge, the stations can be grouped into three distinct groups, one of which is influenced mainly by Ca, Zn and Cu, the other by Fe and S and the third group that was influenced by the others evaluated factors.
339

Efeito da exposição in vitro à bifenila policlorada nº 126 em células 3T3-L1 / In vitro exposure effect of polychlorinated biphenyl n° 126.

Wesley Soares Cruz 29 October 2015 (has links)
A bifenila policlorada n° 126 (3,3\',4,4\',5-Penta-cloro-bifenil, PCB126) é um poluente orgânico persistente (POP), tóxico para os seres vivos. Recentemente, a associação entre a exposição aos POPs e doenças metabólicas têm sido descrita. No entanto, os mecanismos desta toxicidade não estão esclarecidos. Desta forma, este trabalho visou elucidar os efeitos da exposição ao PCB126 sobre pré-adipócitos da linhagem 3T3-L1, diferenciados ou não, focando nos mecanismos de morte celular, proliferação, diferenciação e metabolismo. O PCB 126 foi diluído em DMSO (0,13%). Células 3T3-L1 foram mantidas em meio Dulbecco\'s modified Eagle\'s (DMEM, 5% de CO2 a 37ºC) e sua diferenciação foi realizada pela incubação com solução contendo coquetel adipogênico durante 10 dias. As células foram incubadas com diferentes concentrações de PCB126, DMSO (0,13%) ou DMEM. Células não diferenciadas foram empregadas em ensaios de viabilidade, morte, proliferação, ciclo celular, fragmentação do DNA (citometria de fluxo) e ensaios de produção de espécies reativas de oxigênio (ROS, espectrofotometria de fluorescência). Células diferenciadas foram empregadas para quantificação dos mediadores inflamatórios (ELISA), acúmulo de triglicérides intracelulares (Oil red, microscopia de luz), produção de óxido nítrico (NO, reação de Greiss), expressão do receptor de aril hidrocarboneto (AhR, WB) e do proliferador de peroxissoma (PPAR-&#947;, WB). Os resultados obtidos mostraram que a exposição ao PCB126 (10, 30 ou 100&#181;M; 24, 48 ou 72 h) não alterou a viabilidade e proliferação celular; reduziu a porcentagem de células em apoptose (30, 100&#181;M; 24 ou 72 h); não alterou o ciclo celular (10, 30 ou 100&#181;M; 24 ou 72 h); induziu a fragmentação do DNA (10, 30 ou 100&#181;M; 24h); não induziu a geração de ROS (30, 100&#181;M; 24 ou 72 h); induziu a produção de NO (300&#181;M; 24 ou 72h); não alterou a secreção do fator quimiotáxico para monócito (MCP-1); aumentou a secreção do fator de necrose tumoral (TNF-&#945;; 100 ou 300&#181;M, 72 h) e da interleucina 12 (IL-12; 300&#181;M, 72 h); reduziu a secreção de interleucina 1&#946; (IL-1&#946;, 300 &#181;M, 72 h) e de interleucina 10 (IL-10; 300&#181;M; 24h, 100 ou 300&#181;M; 48 h; 100&#181;M, 72 h); aumentou a expressão de PPAR&#947; (100 ou 300&#181;M, 24h; 300&#181;M, 72h) e de AhR (300&#181;M, 72h); aumentou a concentração de triglicérides intracelulares (100 ou 300&#181;M; 24, 48 ou 72h). Em conjunto, os resultados obtidos mostram as ações diretas do PCB126 em células 3T3-L1 envolvidas na adipogênese, o que reforça, embora que em ensaios in vitro, o papel desta classe de poluentes na obesidade. / The polychlorinated biphenyl (PCB) 126 is a persistent organic pollutant and toxic to human being. The association between exposition to POPs and metabolic diseases has been described. Nevertheless this toxicity mechanism is not yet elucidated. This way this work aim to elucidate the exposure over pre adipocytes 3T3-L1 line to PCB 126, differentiated or not, focused on cellular death mechanisms, proliferation, differentiation and metabolism. The PCB126 was diluted in DMSO (0,13%). 3T3-L1 cells were maintained in Dulbecco´s modified Eagle´s medium (DMEM, 5% CO2 at 37º) and the differentiation process was performed by incubation with adpogenic cocktail solution by 10 days. The cells were incubated with different concentration of PCB126, DMSO (0,13%) or DMEM. Cells not differentiated were used on viability assays, death, proliferation, cell cycle and DNA fragmentation (flow cytometry) and reactive oxygen species production assay (ROS, fluorescence spectrophotometry). Differentiated cells were used to quantify inflammatory mediators (ELISA), Intracellular triglycerides accumulation (Oil red staining, light microscopy), nitric oxide production (NO, Greiss reaction), aril hydrocarbon receptor expression (AhR, Western Blot) and Peroxisome proliferator receptor gamma (PPAR-y, Western Blot). The obtained results showed that exposure to PCB126 (10, 30 or 100 &#181;M; 24, 48 or 72 hours) did not interfere on cellular viability and proliferation; reduced the cells percentage in apoptosis (30, 100 &#181;M; 24 or 72h); did not interfere on cellular cycle (10, 30 or 100 &#181;M; 24 or 72h); induced DNA fragmentation (10, 30 or 100 &#181;M; 24h); did not induced ROS generation (30, 100 &#181;M; 24 or 72h); induced the production of NO (300 &#181;M; 24 or 72h); did not alter the secretion of monocyte chemoattractant protein (MCP-1); enhanced the secretion of tumoral necrosis factor (TNF-&#945;; 100 or 300 &#181;M; 72h) and interleukin 12 (IL12; 300 &#181;M; 72h); reduced secretion of interleukin 1&#946; (IL1&#946; 300 &#181;M; 72h) and interleukin 10 (IL10; 300 &#181;M; 24h; 100 or 300 &#181;M; 48h; 100 &#181;M; 72h); increased PPAR-y expression (100 or 300 &#181;M; 24h; 300 &#181;M; 72h) and AhR (300 &#181;M, 24h); increased intracellular triglycerides concentration (100 or 300 &#181;M, 24, 48 or 72h). In summary the results show direct actions of PCB126 in 3T3-L1 cells evolved on adipogenesis, reinforcing, although in vitro, the role of this pollutant class on obesity.
340

Concentrações de amônia na atmosfera na cidade de São Paulo e sua relação com a poluição veicular / Atmospheric ammonia concentrations in São Paulo city and its relation to vehicle pollution

Silva, Silmara Regina da 07 October 2015 (has links)
Este trabalho teve o objetivo de verificar a existência de correlação entre as concentrações de amônia no município de São Paulo e as concentrações dos poluentes regulamentados associados à emissão veicular. Foi testada a correlação estatística entre as concentrações de amônia e os seguintes parâmetros: fumaça, partículas inaláveis finas, monóxido de carbono, dióxido, monóxido e óxidos de nitrogênio; temperatura e umidade relativa do ar. Os dados utilizados foram fornecidos pela CETESB e medidos na Estação Pinheiros no período de abril/12 a setembro/13. Os resultados obtidos nas análises foram que as concentrações diárias de amônia variaram de 1,3 g/m³ (limite de detecção do método) a 40,0 g/m³, sendo que a média aritmética das concentrações desse período foi de 14,3 g/m³ ± 9,5 g/m³ e a mediana de 14,1 g/m³. Esse valor de média é muito próximo às encontradas em Santiago, Roma, Cidade do México, Pequim e Xian, e os maiores valores diários de amônia foram observados entre novembro/2012 e fevereiro/2013 e as concentrações médias por dia da semana apontaram uma variação entre 12,1 g/m³ a 19,0 g/m³, sendo que a maior média foi observada no domingo. Na comparação com os poluentes atmosféricos, foram observadas algumas tendências de comportamento semelhantes em determinados períodos, porém as correlações foram muito fracas. Com relação aos parâmetros meteorológicos, observou-se que quando ocorreu a máxima de temperatura, o valor de concentração de amônia também foi elevado, porém nos dias em que as concentrações de amônia foram mais altas, as máximas de temperatura não foram as mais elevadas. A correlação encontrada entre a amônia e temperatura foi muito fraca e nos dias com os maiores percentuais de umidade relativa do ar apresentaram valores baixos de concentração de amônia. Não foi possível identificar correlação significante entre concentrações de amônia em relação aos demais poluentes atmosféricos de influência veicular e aos parâmetros meteorológicos temperatura e umidade relativa do ar. Portanto, para o período estudado, as emissões veiculares não influenciaram as concentrações de amônia presentes na região de estudo. Assim, sugere-se o prosseguimento do monitoramento de amônia no ar e estudos posteriores, tendo em vista o aumento de veículos com catalisadores veiculares que podem ocasionar emissão de amônia. / The general objective of this study was to verify the existence of correlation between the ammonia concentrations in São Paulo city and the concentrations of regulated pollutants associated with vehicle emissions. The concentration of air pollutants: black smoke, fine particulate matter, carbon monoxide and nitrogen dioxide, monoxide and oxides; temperature and relative humidity were statistically tested. CETESB measured the pollutants data at Pinheiros Station from April/12 to September/13. The daily ammonia concentrations ranged from 1.3 g/m³ (method detection limit) to 40.0 g/m³ and the average concentrations of this period was 14.3 g/m³ ± 9.5 g/m³ and the median 14.1 g/m³. This average value is very close to those found in Santiago, Rome, Mexico City, Beijing and Xi\'an, the largest daily ammonia values were observed between November/2012 and February/2013, and the average concentrations by day of week pointed a variation between 12.1 to 19.0 g/m³. The highest average was observed on Sunday. In the comparison between the atmospheric pollutants and air temperature and humidity some similar trends behavior were observed in certain periods, but the correlations were very weak. It was not possible to identify a significant correlation between ammonia concentration with air pollutants vehicular influence and meteorological parameters temperature and relative humidity. Therefore, for the period studied, vehicle emissions did not affect the concentrations of ammonia present in the study area. It is suggested to continue the monitoring of ammonia in the air and further studies due to the increase of vehicles equipped with catalysts, which can cause emission of ammonia.

Page generated in 0.0284 seconds