Spelling suggestions: "subject:"[een] SHEAR STRENGTH"" "subject:"[enn] SHEAR STRENGTH""
121 |
Resistência ao cisalhamento de bráquetes ortodônticos cerâmicos colados com diferentes compósitos e irradiados com laser de CO2 / Shear strength of ceramic orthodontic brackets bonded with different composites and irradiated with CO2 laserDenise de Souza Matos 25 April 2013 (has links)
O objetivo do trabalho foi avaliar a resistência ao cisalhamento de bráquetes ortodônticos cerâmicos com base de retenção química e mecânica, colados com diferentes compósitos e irradiados com laser de CO2. Foram utilizados 120 pré-molares humanos hígidos, suas coroas foram incluídas em resina acrílica e as faces vestibulares planificadas e polidas com lixas d\'água até exposição de 5mm esmalte. Posteriormente, as raízes dos dentes foram incluídas em tubos de PVC também com resina acrílica de forma que a face vestibular ficasse perpendicular à base do tubo. Os 120 corpos de prova foram divididos em 8 grupos (n=15), sendo 2 controles e 6 experimentais. Nos grupos 1 e 2 (controles) o compósito utilizado para colagem foi o Transbond XT, sendo que no grupo 1 foi colado o bráquete cerâmico Mystique (retenção mecânica) e no grupo 2 o bráquete cerâmico Fascination (retenção química). Nos grupos experimentais 3, 4 e 5 foi colado o bráquete Mystique com os compósitos Transbond XT, Concise e Z250, respectivamente. Nos grupos 6, 7 e 8 foi colado o bráquete Fascination com os mesmos compósitos dos grupos 3, 4 e 5, na mesma sequência. Nos grupos experimentais, após a colagem, os bráquetes foram irradiados com laser de CO2 com 10W de potência por 3 segundos e pulso de 0,01 segundo. Imediatamente após a irradiação foi realizado o teste de resistência ao cisalhamento da colagem em máquina universal de ensaios mecânicos (Emic DL 500) à velocidade de 0,5 mm/minuto. Após o teste, as superfícies avaliadas por meio do Índice de Remanescente Adesivo (IRA) e submetidas à Microscopia Eletrônica de Varredura (MEV) para investigação de eventuais fraturas. Os dados de resistência ao cisalhamento foram submetidos à Análise de Variância ANOVA e posteriormente teste de Tukey. O teste de Mann-Whitney foi utilizado para a avaliação do IRA. Os resultados mostraram que os grupos experimentais apresentaram valores de resistência ao cisalhamento menores quando comparados aos controle (p 0,05). O bráquete Mystique (retenção mecânica) apresentou valores maiores de resistência ao cisalhamento e o compósito Z 250 foi o que apresentou menor força de adesão após irradiação com laser de CO2. Os grupos 5 e 8 foram os que apresentaram maior média do IRA e para todas as superfícies avaliadas o modo de fratura mais prevalente foi a fratura adesiva . Concluiu-se que o laser de CO2 foi eficaz como auxiliar na descolagem de bráquetes cerâmicos de retenção química e mecânica. / The objective of this study was to evaluate the shear strength of the ceramic orthodontic brackets based in chemical and mechanical restraint, bonded with different composites and irradiated with CO2 laser was evaluated. Healthy human premolars (120) were used and their crowns were embedded in acrylic resin and the buccal surfaces flattened and polished with sandpaper until exposure of 5 mm of enamel. Subsequently, the roots of the teeth were included in PVC pipes also with acrylic resin so that the labial surface was perpendicular to the base of the pipe. The 120 samples were divided into 8 groups (n = 15), 2 being the control groups and 6, the experimental groups. In groups 1 and 2 (controls) the composite used for bonding was Transbond XT. Group 1 was glued to the ceramic bracket Mystique (by mechanical retention) and the group 2, with ceramic bracket Fascination (by chemical restraint). In the experimental groups 3, 4 and 5 Mystique brackets were glued with Transbond XT, Concise and Z250, respectively. In groups 6, 7 and 8 the Fascination bracket were glued with the same composites of groups 3, 4 and 5 and in the same sequence. In the experimental groups, after bonding, the brackets were irradiated with CO2 laser with 10W of power for 3 seconds and per pulse 0.01 seconds. Immediately after irradiation shear strength tests were performed on shear bonding with mechanical universal testing machines (Emic DL 500) at a speed of 0.5 mm/minute. After testing, the surfaces were evaluated using the Adhesive Remnant Index (ARI) and submitted to scanning electron microscopy (SEM) to investigate possible fractures. The shear strength data were subjected to analysis of variance with ANOVA and Tukey test later. The Mann-Whitney test was used to evaluate the ARI. The results showed that experimental groups showed lower shear strength values, comparing to the control groups (p 0.05). The bracket Mystique (mechanical retention) showed higher shear strength values and the Z 250 composite showed the lowest adhesion strength after irradiation with CO2 laser. Groups 5 and 8 presented the highest average of IRA and for all the surfaces that were evaluated the most prevalent fracture mode was the adhesive one. It was concluded that the CO2 laser was effective as an aid in bracket debonding of ceramic with chemical and mechanical retention.
|
122 |
Stress-strain-strength anisotropy of varved clays.Sambhandharaksa, Surachat January 1977 (has links)
Thesis. 1977. Sc.D.--Massachusetts Institute of Technology. Dept. of Civil Engineering. / MICROFICHE COPY AVAILABLE IN ARCHIVES AND ENGINEERING. / Vita. / Bibliography: leaves 381-386. / Sc.D.
|
123 |
Cone penetration in clays.Vivatrat, Vitoon January 1978 (has links)
Thesis. 1978. Sc.D.--Massachusetts Institute of Technology. Dept. of Civil Engineering. / MICROFICHE COPY AVAILABLE IN ARCHIVES AND ENGINEERING. / Bibliography: leaves 416-426. / Sc.D.
|
124 |
Método de ensaio para a determinação da resistência ao cisalhamento em elementos estruturais de madeira de Pinus spp. / Test method for the determination of shear strength in timber structural elements in Pinus spp.Santos, Caio Victor Fernandes dos 28 July 2016 (has links)
Tendo em vista a inserção das madeiras de reflorestamento nos projetos estruturais, têm-se a necessidade de realizar ensaios de caracterização que sejam mais adequados. O documento normativo ABNT NBR 7190:1997 padroniza os ensaios mecânicos para projetos de estruturas de madeira no Brasil. Estes ensaios são realizados a partir de testes em corpos de prova de pequenas dimensões e isentos de defeitos. Porém, a incidência de defeitos ocorre nas peças utilizadas em estruturas e, por isso, podem ocorrer diferenças consideráveis de resistência entre os corpos de prova isentos de defeitos e os corpos de prova estruturais. Os documentos normativos ASTM ISO 13910:2005 e EUROCODE EN 408:2010 estabelecem um padrão de ensaios com a utilização de peças de tamanho estrutural. Portanto, o presente estudo busca definir as possíveis diferenças entre os ensaios realizados de acordo com ambas as normas. Foram realizados ensaios para a determinação da resistência ao cisalhamento paralelo às fibras com a madeira de Pinus spp., de acordo com as normas ABNT NBR 7190:1997 e ASTM ISO 13910:2005. Devido a problemas de colagem não foram concluídos ensaios segundo a norma EUROCODE EN 408:2010. A análise dos resultados permitiu perceber que a utilização da norma ABNT NBR 7190:1997 pode indicar dados inexatos em relação à real resistência do material em questão. / Considering the insertion of reforesting woods in structural designs that has the need to perform characterization tests which are more suitable. The normative document ABNT NBR 7190:1997 standardizes the mechanical tests for wooden structures projects. These tests are carried out from tests in small specimens and no defects. However, the incidence of defects occur in parts used in structures, therefore, can occur considerable differences in resistance between the samples free of defects and structural specimens. The normative document ASTM ISO 13910:2005 and EUROCODE EN 408:2010 establishes a test pattern with the use of structural specimens. Therefore, the present study seeks to define the possible differences between the tests performed in accordance with both standards. Assays were performed to determine the shear strength parallel fibers of Pinus spp., according to ABNT NBR7190:1997 and ASTM ISO 13910:2005. There was an attempt to hold up tests following the premises of EUROCODE EN 408:2010. The results allowed the perception of evidence that the use of ABNT NBR 7190 standard may indicate infidels data regarding the real strength of the material in question.
|
125 |
Resistência de união ao cisalhamento de cimentos resinosos autoadesivos ao esmalte e dentina / Shear bond strength of self-adhesive resin cements to enamel and dentinRodrigues, Raphaela Farias 11 March 2013 (has links)
O objetivo deste trabalho foi avaliar a resistência de união ao cisalhamento dos cimentos autoadesivos RelyX U100 (3M/ESPE) e RelyX U200 (3M/ESPE) ao esmalte e à dentina, em função de diferentes tratamentos da superfície e comparando-os com o cimento resinoso RelyX ARC (3M/ESPE). Cento e vinte incisivos bovinos foram selecionados, limpos e armazenados em solução supersaturada de timol 0,1% para evitar a proliferação de micro-organismos. As coroas foram separadas das raízes e incluídas com resina epóxica em tubos de PVC. Utilizaram-se lixas de carbeto de silício, sob refrigeração, para obtenção de superfícies vestibulares planas de esmalte e dentina. Após a delimitação das áreas destinadas à cimentação com fitas autocolantes, a amostra foi distribuída em 12 grupos (n = 10) de acordo com o substrato, cimento e realização ou não do condicionamento com ácido fosfórico 37% em E-U100 (esmalte + RelyX U100), EU100-C (esmalte + RelyX U100 + condicionamento ácido), E-U200 (esmalte + RelyX U200), E-U200-C (esmalte + RelyX U200 + condicionamento ácido), E-ARC (esmalte + adesivo + RelyX ARC), E-ARC-C (esmalte + RelyX ARC + condicionamento ácido e adesivo), D-U100 (dentina + Relyx U100), D-U100-C (dentina + RelyX U100 + condicionamento ácido), D-U200 (dentina + Relyx U200), D-U200-C (dentina + RelyX U200 + condicionamento ácido), D-ARC (dentina + primer e adesivo + RelyX ARC) e D-ARC-C (dentina + RelyX ARC + condicionamento ácido e adesivo). Uma matriz de teflon bipartida (3 mm de diâmetro e 2 mm de altura) permitiu a confecção de cilindros dos cimentos coincidentes com as áreas delimitadas. Os testes de resistência ao cisalhamento foram realizados, após 7 dias de armazenagem em saliva artificial, numa máquina de ensaio universal EMIC, a velocidade de 0,5 mm/min e com célula de carga de 50 kg. A análise da fratura foi realizada por meio do microscópio digital portátil. Com caráter ilustrativo, dois espécimes de cada grupo foram observados em microscopia eletrônica de varredura. Os dados foram analisados pelo teste ANOVA - 3 critérios e teste Tukey (5%). Não se observou diferença entre os cimentos RelyX U100 e RelyX U200. No esmalte, o RelyX ARC apresentou maior resistência do que os autoadesivos, porém com o prévio condicionamento ácido da superfície os autoadesivos mostraram-se superiores. Em dentina, não houve diferença significante entre os grupos. A maioria das fraturas foi do tipo adesiva. Considerando as limitações deste estudo, conclui-se que os cimentos resinosos autoadesivos podem ser utilizados em alternativa aos cimentos resinosos convencionais nas situações com pouca ou nenhuma estrutura em esmalte. Quando houver a presença considerável de esmalte deve-se priorizar o emprego dos cimentos resinosos convencionais ou os autoadesivos associados ao condicionamento com ácido fosfórico previamente à cimentação. / The objective of this study was to evaluate the shear bond strength of selfadhesive cements RelyX U100 (3M/ESPE) and RelyX U200 (3M/ESPE) to enamel and dentin, due to different surface treatments and comparing them with resin cement RelyX ARC (3M/ESPE). One hundred and twenty bovine incisors were selected, cleaned and stored in supersaturated solution of 0.1% thymol to prevent the proliferation of micro-organisms. The crowns were separated from the roots and embedded with epoxy resin in PVC tubes. It was used silicon carbide sandpaper under refrigeration for obtaining flat buccal surfaces of enamel and dentin. After the delimitation of cementations areas with adhesive tape, the sample was distributed into 12 groups (n = 10) under the substrate, cement and conducting or absence of etching with 37% phosphoric acid in E-U100 (enamel + RelyX U100), E-U100-C (enamel + RelyX U100 + etching), E-U200 (enamel + RelyX U200), E-U200-C (enamel + RelyX U200 + etching), E-ARC (enamel + adhesive + RelyX ARC), EARC-C (enamel + RelyX ARC + etching and adhesive), D-U100 (dentin + RelyX U100), D-U100-C (dentin + RelyX U100 + etching), D-U200 (dentin + RelyX U200), D-U200-C (dentin + RelyX U200 + etching), D-ARC (dentin + RelyX ARC + primer and adhesive) and D-ARC-C (dentin + RelyX ARC + etching and adhesive). A split Teflon mold (3 mm diameter and 2 mm height) allowed manufacturing of cement cylinders, which coincide with delimited areas. The shear strength tests were performed after 7 days of storage in artificial saliva, a universal testing machine EMIC, speed 0.5 mm/min and load cell of 50 kg. The analysis of the fracture was performed using the portable digital microscope. With illustrative, two specimens of each group were observed in scanning electron microscopy. Data were analyzed by ANOVA - 3 criteria and Tukey test (5%). No difference was observed between selfadhesive cements RelyX U100 and RelyX U200. In enamel, the RelyX ARC showed higher resistance than the self-adhesive, but with the prior etching of the surface selfadhesive proved superior. In dentine, no significant difference between groups. Most fractures were type adhesive. Considering the limitations of this study it is concluded that the self-adhesive resin cements can be used as an alternative to conventional resin cements in situations with little or no enamel structure. When there is a considerable presence of enamel should prio ritize the employment of conventional resin cements or self-adhesive associated with phosphoric acid etching prior to cementation.
|
126 |
Mecanismos de penetração dinâmica em solos granulares / Dynamic penetration mechanisms in cohesionless soilsLobo, Bianca de Oliveira January 2009 (has links)
Ensaios de penetração dinâmica são ferramentas de investigação geotécnica de fácil execução e baixo custo. Estas características tornaram o ensaio SPT na técnica de investigação mais utilizada em diversos países como Canadá, Estados Unidos, Japão e principalmente, no Brasil. Em contrapartida, a penetração dinâmica de amostradores produz um complexo mecanismo de reação do solo, função da energia entregue ao sistema e da capacidade de absorção desta energia pelo próprio solo. Na prática de engenharia, este mecanismo é simplificado através do uso de abordagens empíricas. Pesquisas na década de 1970, realizadas por Schmeertmmann & Palacius (1979) e Schmertmmann (1979), avaliaram a energia inserida no sistema haste-amostrador objetivando a padronização do ensaio SPT para diferentes equipamentos e procedimentos. Pesquisas recentes de interpretação do ensaio utilizam conceitos de conservação de energia e trabalho realizado pelo amostrador ao penetrar no solo, visando equacionar a resistência mobilizada (eg. Oderebrecht, 2003; Odebrecht et al, 2005; Schnaid, 2005). Na presente pesquisa, são utilizados os conceitos de conservação de energia, associados com equações de equilíbrio dinâmico e com a teoria de expansão de cavidades (Vésic, 1972) para desenvolver uma rotina de simulação numérica capaz de modelar os principais mecanismos de reação do solo devido cravação de um amostrador. A partir da validação da rotina de simulação numérica para ensaios dinâmicos de distintas geometrias (ensaios SPT, ILPT, NALPT e RLPT), avalia-se a variabilidade da energia entregue ao solo devido às diferenças de compacidade do solo, eficiência do golpe, geometria do martelo, tipo e comprimento da composição de hastes. Destas simulações, é possível observar as diferenças de resultados entre ensaios de distintas geometrias de martelo e composição de hastes, concluindo-se que pequenas variações geométricas produzem diferenças no índice de resistência à penetração. Como conseqüência, sugere-se que a interpretação dos resultados depende de um método racional de análise capaz de incorporar estes efeitos à estimativa de propriedades de comportamento de solos. Na identificação dos mecanismos de ruptura para solos de diferentes compacidades foram desenvolvidas duas metodologias que permitem estimar a resistência ao cisalhamento de solos granulares a partir do índice de resistência à penetração medida em ensaios de penetração dinâmica. A primeira metodologia utiliza a rotina de simulação numérica desenvolvida através de uma análise do Problema do valor inverso, enquanto a segunda proposta utiliza os pressupostos do Teorema de Buckingham no estabelecimento de uma solução analítica que permita estimar o ângulo de atrito de pico de materiais granulares. As duas alternativas foram validadas através de estudo de casos, permitindo concluir que as soluções produzem estimativas de ângulo de atrito realistas, de mesma ordem de magnitude que outras abordagens difundidas no meio técnico e compatíveis com resultados de ensaios de campo e laboratório. / Dynamic penetration tests are simple, economic and easily performed geotechnical investigation tools. Due to these general characteristics, the test has been used systematically in many countries such as Canada, United States, Japan and Brazil. Despite the attractive conditions of performing a simple test, dynamic penetration of a any tool into a soil mass produces a complex soil reaction mechanism that depends on the energy delivered to the soil, as well as the capability of the soil to absorb this energy. Given this complexity a simple approach of interpreting the test by using empirical correlations has prevailed. In 1970, Schmeertmmann & Palacius (1979) and Schmertmmann (1979) develop the first rational methodology to compute the energy delivered to the rod-sampler system that has been incorporated to engineering practice by normalizing different practices in terms of a reference energy. Most recent researches of SPT test interpretation make uses of energy concepts and work to compute the mobilized soil-resistance due to the sampler penetration (e.g. Oderebrecht, 2003; Odebrecht et al, 2005; Schnaid, 2005). In present research these recent approaches are extended through the use of energy concepts associated with dynamic equilibrium equations and cavity expansion theory (Vésic, 1972). Constitutive equations have been incorporated to a numerical simulation routine able to reproduce the some of the most important processes of soil reaction during dynamic in cohesionless soil. The model validation for different dynamic penetration test geometries (SPT, ILPT, NALPT and RLPT) enabled the energy delivered to soil to be evaluated and the effects of soil density, blow efficiency, hammer geometry, rod type and length to be assessed. From a number of simulations, it was possible to describe the differences related typical geometrical changes (i.e. hammer length, rod cross section and length). Conclusions from the analysis are that small geometrical changes in hammer and rod characteristics - typically observed in different SPT practices - produce differences into the measured blow count. As consequence, it is suggested that interpretation of dynamic penetration test results will depend on a model capable of incorporating all these effects when attempting to derive soil constitutive parameters. This is one of the outputs of the present study that lead to the development of two rational methodologies to assess the internal friction angle of cohesionless soils from dynamic penetration blow count. The first one uses the numerical simulation routine as a Inverse Boundary Value problem while the second one uses the Buckingham’s Theorem to develop an analytical equations that correlates the N-SPT with the soil shear strength. Both methodologies have been validated by a series of case studies designed to demonstrate that the proposed solution produces friction angle values of the same order of magnitude of other approaches and compatible to measurements produced by laboratory and in situ tests.
|
127 |
Efeito do armazenamento prolongado em água sobre a resistência de união entre resinas para reembasamento e resina para base de prótese /Azevedo, Andréa. January 2005 (has links)
Orientador: Ana Lucia Machado / Banca: Eunice Teresinha Giampaolo / Banca: Cláudio Rodrigues Leles / Resumo: Este estudo avaliou o efeito da armazenagem prolongada em água sobre a resistência de união entre uma resina acrílica para base de prótese (Lucitone 550) e quatro resinas para reembasamento (Kooliner - K, New Truliner - NT, Tokuso Rebase - TR e Ufi Gel Hard - UGH). Além disso, a resistência de união ao cisalhamento de corpos-de-prova reembasados com a resina acrílica para base de prótese L foi avaliada para comparação. Cilindros (20 mm X 20 mm) de resina acrílica L foram polimerizados (em água a 70°C por 90 minutos, e por 30 minutos à temperatura de ebulição) de acordo com instruções do fabricante e imersos em água destilada (37 l 1°C por 48 l 2 horas). As superfícies de união foram polidas com lixa de granulação 240, escovadas com detergente (20 segundos), limpas com água destilada e secas com papel absorvente. As superfícies foram, então, preparadas por meio da aplicação do monômero da resina L (180 segundos) para a resina K e com os agentes de união (20 segundos) para as demais resinas. Uma fita adesiva com orifício (3,5 mm) foi fixada sobre a superfície tratada para padronizar a área de união. Cada cilindro foi acoplado a uma matriz metálica bipartida com um orifício central (3,5 mm X 5,0 mm). Os materiais para reembasamento foram manipulados, inseridos na matriz e polimerizados de acordo com as instruções dos fabricantes. Após a polimerização, os corpos-de-prova de cada material reembasador foram divididos em cinco grupos (n=8) e submetidos aos testes de cisalhamento (velocidade = 0,5 mm/min). Para o grupo controle (G1), os testes foram realizados imediatamente após a polimerização, para as resinas de reembasamento, e após os corpos-de-prova terem sido imersos em água (37 l 1° C) por 48 l 2 horas para a resina de base L. Os corpos-de-prova relativos aos Grupos 2, 3 e 4 foram testados após terem sido armazenados em água (37 l 1° C)...(Resumo completo, clicar acesso eletrônico abaixo) / Abstract: This study evaluated the effect of long-term water storage on the shear bond strength between one heat-polymerizing denture base acrylic resin (Lucitone 550-L) and four autopolymerizing reline resins (Kooliner- K, New Truliner-NT, Tokuso Rebase-TR, Ufi Gel Hard -UGH). Also, the shear bond strength of specimens relined with the denture base resin L was evaluated, for comparison. Cylinders (20mm x 20mm) of the resin L were processed (in water at 70°C for 90 minutes, and 30 minutes at boiling temperature), according to the manufacturer's instructions, and stored in distilled water (37 l 1° C for 48 l 2 hours). The surfaces to be bonded were ground with 240-grit silicon carbide paper, brushed with detergent (20 s), washed in distilled water, and blot-dried. The bonding sites were prepared by painting the surfaces with L monomer (180 seconds) for resin K, and with the bonding agents (30 seconds) for the other resins. A tape with a circular opening (3.5 mm) was placed on the treated surfaces to provide a uniform bonding area. Each cylinder was placed in a stainless steel split mold with a center hole (3.5x5.0 mm). The reline materials were mixed, applied to the mold, and polymerized according to the manufacturers' instructions. After polymerization, specimens of each reline material were divided into 5 groups (n=8), and submitted to shear tests (at a 0.5 mm/min cross-head speed). For control group (G1), the tests were performed immediately after processing for the reline resins, and after the specimens had been stored in water (37 l 1° C) for 48 l 2 hours for the denture base resin L. Groups G2, G3 and G4 specimens were tested after being stored in water (37 l 1° C) for 7 days, 3 months, and 6 months, respectively. The fractured surfaces were examined using scanning electron microscope and an image analysis system to determine the percentage surface area that remained...(Complete abstract click elctronic access below) / Mestre
|
128 |
Efeito da desinfecção química e por microondas na alteração dimensional e resistência de união de resinas para reembasamento imediato e resina termopolimerizável /Gonçalves, Alessandro Ribeiro. January 2005 (has links)
Orientador: Ana Lucia Machado / Banca: Carlos Eduardo Vergani / Banca: João Neudenir Arioli Filho / Banca: Arlindo Abreu de Castro Filho / Banca: Eduardo Miyashita / Resumo: Esse estudo avaliou o efeito da desinfecção química e por irradiação com microondas sobre a estabilidade dimensional e a resistência ao cisalhamento entre uma resina termopolimerizável para base de prótese (Lucitone 550-L) e quatro resinas autopolimerizáveis para reembasamento (Kooliner- K, New Truliner-NT, Tokuso Rebase-TR, Ufi Gel Hard -UGH). Foi avaliada também a resistência ao cisalhamento de corpos-de-prova reembasados com a resina L. Para cada material, 48 corpos-de-prova (50 mm diâmetro x 0.5 mm espessura) foram preparados, seguindo-se as recomendações dos fabricantes, utilizando-se uma matriz metálica circular com pontos de referência (A, B, C e D). Um projetor de perfil Nikon foi utilizado para mensurar a distância entre os pontos de referências (AB e CD) na matriz metálica e nos corpos-de-prova. Os corpos-de-prova foram divididos em 6 grupos (n=8) e as mensurações foram realizadas após as seguintes condições experimentais: G1- 2 ciclos de desinfecção química (corpos-de-prova imersos em solução de perborato de sódio a 3,8% aquecida a 50º C por 10 minutos); G2- 2 ciclos de desinfecção com microondas (corpos-de-prova imersos em 200 mL de água e irradiados com 650 W por 6 minutos); G3- 7 ciclos de desinfecção química; G4- 7 ciclos de desinfecção com microondas; C1- grupo controle 1- após a polimerização para as resinas de reembasamento e após imersão em água a 37° C por 48 + 2 horas para a resina de base; C2- grupo controle 2- corpos-de-prova imersos em água a 37° C por 7 dias. Para os grupos G3 e G4, os corpos-de-prova foram mantidos em água a 37° C entre os ciclos de desinfecção. As diferenças entre as mensurações realizadas nos corpos-de-prova e as da matriz foram calculadas e expressas em porcentagem de alteração dimensional linear. Para avaliar a resistência de união, foram confeccionados cilindros ...(Resumo completo, clicar acesso eletrônico abaixo) / Abstract: This study evaluated the effect of chemical and microwave disinfection on the linear dimensional change and the shear bond strength between one heat-polymerizing denture base acrylic resin (Lucitone 550-L) and four autopolymerizing reline resins (Kooliner- K, New Truliner-NT, Tokuso Rebase-TR, Ufi Gel Hard -UGH). Also, the shear bond strength of specimens relined with the denture base resin L was evaluated, for comparison. For each material, 48 disks (50 mm diameter and 0.5 mm thickness) were made by using a stainless steel split mold with reference points (A, B, C and D), following the manufacturers' instructions. A Nikon optical comparator was used to measure the distances between the reference points (AB and CD) on the stainless steel mold and on the specimens. Specimens were divided into 6 groups (n=8) and the measurements were made after the following conditions: G1- 2 cycles of chemical disinfection (specimens immersed in 3,8% sodium perborate solution at 50° C for 10 minutes); G2- 2 cycles of microwave disinfection (specimens immersed in 200 mL of water, and irradiated with 650 W for 6 min); G3- 7 cycles of chemical disinfection; G4- 7 cycles of microwave irradiation; G5- after polymerization for the reline resins and after the specimens had been stored in water at 37° C for 48 + 2 hours; G6- specimens immersed in water at 37° C for seven days. For the groups G3 and G4, the specimens were disinfected daily, and stored in water at 37° C between disinfection. The differences between the measurements made on the specimens and on the stainless steel mold were calculated and expressed as percentage of linear dimensional changes. To evaluate the bond strength, cylinders (20mm x 20mm) of the resin L were processed (in water at 70°C for 90 minutes, and 30 minutes at boiling temperature), according to the manufacturer's instructions ...(Complete abstract, click electronic access below) / Doutor
|
129 |
Resistência adesiva de bráquetes ortodônticos colados com sistemas adesivos convencionais e auto-condicionantes ao esmalte bovino após ciclos térmicos e termomecânicos /Torres, Luciana Marcondes Sarmento. January 2011 (has links)
Orientador: Rebeca Di Nicoló / Banca: Clovis Pagani / Banca: Daniela Raggio / Resumo: Este estudo in vitro teve como objetivo avaliar a influência das ciclagens térmica e termomecânica na resistência adesiva de bráquetes colados em esmalte bovino com primers convencionais e auto-condicionates. Noventa incisivos bovinos foram aleatoriamente divididos em 2 grupos (G), de acordo com o primer utilizado: XT (n=45) - bráquetes colados com primer convencional (Transbond XT/3M, Unitek); SEP (n=45) - bráquetes colados com primer auto-condicionante (Transbond Plus SEP/3M, Unitek). Após a colagem dos bráquetes, cada grupo foi subdividido em 3 subgrupos (n=15): SC (sem ciclagem) - as amostras não receberam nenhum tipo ciclagem; CT (ciclagem térmica) - as amostras receberam apenas ciclagem térmica (500 ciclos de 50C a 550C); CTM (ciclagem termomecânica) - as amostras receberam ciclagem termomecânica (100.000 ciclos de 50C a 550C). A seguir, foi realizado o teste de cisalhamento em uma máquina de ensaios universal (EMIC) a uma velocidade de 1mm/min com célula de carga de 100kg. Após o descolamento dos bráquetes, amostras de cada grupo foram submetidas à avaliação microscópica em microscópio eletrônico de varredura, a fim de analisar a superfície do esmalte e quantificar o Índice de Adesivo Remanescente (IAR) sobre a superfície. Os resultados mostraram que o grupo SEP apresentou maior resistência adesiva (14,70±4,85 MPa) quando comparado com o grupo XT (11,27±4,48 MPa). Para os grupos XT, a resistência adesiva manteve-se semelhante independente do tipo de ciclagem (SC, 11,44 MPa; CT, 11,20 MPa; CTM,11,19 MPa), enquanto que para os grupos SEP o subgrupo CTM foi o que apresentou maiores valores de resistência adesiva (16,84 MPa), seguido do CT (14,99 MPa) e SC (12,26 MPa). O teste ANOVA - 2 fatores revelou que o efeito interação não é estatisticamente significante; indicando, assim, que o efeito do tipo de ciclagem para o grupo XT é o mesmo ... (Resumo completo, clicar acesso eletrônico abaixo) / Abstract: The aim of this in vitro study was to evaluate the influence of thermal and thermomechanical cycling on shearbond strength of orthodontic brackets bonded with conventional and self-etching primers. 90 bovine incisors were randomly divided into 2 groups (G) according to the primer: XT (n=45) - brackets bonded with conventional primer (Transbond XT/3M, Unitek); SEP (n=45) - brackets bonded with self-etching primer (Transbond Plus SEP/3M, Unitek). After bonding, each group were divided into 3 subgroups (n=15): NC (no cycling) - the specimens did not receive any kind of cycling; TC (thermal cycling) - the specimens received only thermal cycling (500 cycles); TMC (thermomechanical cycling) - the specimens received thermomechanical cycling (100.000 cycles). Next, the shearbond strength test was performed in a universal testing machine (EMIC) at a crosshead speed of 1mm/min. After debonding, specimens of each group were submitted to microscopic evaluation in order to analyze the enamel surface, the adhesive penetration and quantify the Adhesive Remaining Index (ARI). The results showed that the SEP group presented higher bond strength (14,70±4,85 MPa) compared with XT (11,27±4,48 MPa). For XT, the bond strength remained similar despite cycling (NC, 11,44 MPa; TC, 11,20 MPa; TMC,11,19 MPa), meanwhile for SEP, the subgroup TMC showed higher values of bond strength (16,84 MPa), followed by TC (14,99 MPa) e NC (12,26 MPa). 2-way ANOVA test indicated that the interaction effect is not statistically different, so the kind of cycling effect for XT is equal for SEP. But the primer effect (XT vs SEP) is statiscally significant. According to the ARI , the group that presented the highest remaining adhesive on the enamel surface was SEP/TMC (ARI=3). The results showed that self-etching primers can be safely used in orthodontic practice because presents adequate values of bond strength ... (Complete abstract click electronic access below) / Mestre
|
130 |
Avaliação da influência da sucção na resistência não drenada de um solo residual compactado utilizando o ensaio de palheta de laboratório. / Evaluation of the influence of Suction on undrained shear strength of a compacted residual soil using the minivane test.Norman Eddy Chura Vilcanqui 12 December 2014 (has links)
A presente pesquisa apresenta resultados de uma série de ensaios de palheta de laboratório, com a finalidade de determinar a resistência não drenada de um solo residual compactado. Durante o ensaio foram realizadas medições continuas de sucção com uso de um tensiômetro de alta capacidade, disposto na base dos corpos de prova, sendo este procedimento inédito. O objetivo secundário do estudo é a avaliação de aspectos relacionados com a variação da resistência e sucção quando a distância do tensiômetro de alta capacidade é modificada com relação à superfície inferior do plano de ruptura pré-estabelecido. Para a realização destes experimentos foram modificados e adaptados equipamentos de laboratório. O estudo foi realizado com um solo residual de gnaisse compactado obtido do antigo campo experimental da Escola Politécnica da Universidade de São Paulo. O estudo constata que o valor medido da resistência não drenada é afetado pela proximidade do tensiômetro a palheta. / This research presents results of a series of mini-vane tests in order to determine the undrained shear strength of a residual compacted soil. During the tests and for the first time, continuous measurement of suction has been made using a high capacity tensiometer placed at the base of the specimen. The secondary aim of this study is to evaluate aspects related to resistance and suction variation when the distance of the high capacity tensiometer is modified in relation to the lower pre-set failure surface. For this reason laboratory equipments were modified and adapted in order to perform the study. The tests were performed with a compacted residual soil of gneiss obtained from the experimental site of the Polytechnical School of the University of São Paulo. The study showed that the undrained shear strength is affected when the vane are closer to the tensiometer.
|
Page generated in 0.0555 seconds