• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 306
  • 96
  • 34
  • 21
  • 15
  • 9
  • 8
  • 3
  • 3
  • 3
  • 2
  • 2
  • 2
  • 2
  • 1
  • Tagged with
  • 561
  • 561
  • 314
  • 292
  • 117
  • 83
  • 76
  • 74
  • 67
  • 66
  • 60
  • 59
  • 58
  • 58
  • 51
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
381

Bridging the divide between resource management and everyday life: smart metering, comfort and cleanliness

Strengers, Yolande Amy-Adeline, Yolande.strengers@rmit.edu.au January 2010 (has links)
Smart metering residential demand management programs, such as consumption feedback, variable pricing regimes and the remote control of appliances, are being used to respond to the resource management problems of peak electricity demand, climate change and water shortages. Like other demand management programs, these strategies fail to account for (and respond to) the reasons why people consume resources in their homes, namely to carry out everyday practices such as bathing, laundering, heating and cooling. In particular, comfort and cleanliness practices together constitute most of Australia's potable water consumption in urban centres, and represent most of household energy consumption. In addition, new household cooling practices involving air-conditioning appliances are the major contributor to the nation's rising peak electricity demand, which overloads the electricity system on hot days, costing consumers millions of dollars each year. The oversight of comf ort and cleanliness practices in smart metering demand management programs is concerning because these practices are continuing to shift and change, often in more resource-consuming directions, potentially negating the resource savings achieved through demand management programs. This thesis aims to bridge the problematic divide between the policies and strategies of demand managers, and the day-to-day practices which constitute everyday life. Using the empirical 'hook' of smart metering demand management programs and the everyday practices of comfort and cleanliness, this thesis develops a practice-based conceptual framework to study, understand and analyse these practices and the ways in which smart metering demand management programs reconfigure or further entrench them. A series of qualitative methods were employed in studying 65 households across four research groups, focusing specifically on the household practices of heating, cooling, bathing, laundering, toilet flushing and house cleaning. In addition, 27 interviews were conducted with smart metering industry stakeholders involved or implicated in delivering demand management strategies. Together, these lines of inquiry are used to analyse householders' existing and changing comfort and cleanliness practices, the role of several smart metering demand management strategies in reconfiguring these practices, and potential avenues and opportunities for further practice change in less resource-intensive directions. In particular, this thesis highlights the inherent contradictions and problems in accounting for everyday practices within the dominant demand management paradigm, and offers an alternative paradigm termed the co-management of everyday practices. The thesis concludes by briefly identifying the ways in which smart metering could potentially constrain or catalyse a transition towards this new paradigm.
382

Ventilation par mélange utilisant des dispositifs de diffusion munis d’inserts lobés : analyse des écoulements moteurs et du confort thermique induit / Mixing ventilation using air diffusion devices equipped with lobed inserts : airflow pattern and induced thermal comfort analysis

Bragança, Pierre 05 October 2017 (has links)
Cette thèse porte sur la ventilation par mélange à haute induction pour le bâtiment au moyen de diffuseurs d’air innovants munis de promoteurs de tourbillons. Il s’agit d’inserts lobés, introduits au sein de diffuseurs d’air commerciaux, sans en modifier le processus de fabrication. L’innovation est née de travaux antérieurs et a fait récemment l’objet d’un brevet européen. Sa mise en situation à l’échelle 1 en conditions typiques de chauffage et de climatisation, constitue l’objectif premier des présents travaux. Par une démarche expérimentale, l’impact des inserts lobés sur la topologie de l’écoulement moteur, sur le confort thermique induit en zone d’occupation d’une cellule climatique thermiquement gardée, et sur les pertes de charges et le bruit générés, sont évalués. Les écoulements moteurs sont analysés par PIV 2D2C grand champ, et le confort thermique est évalué en zone d’occupation à l'aide d’un ensemble de capteurs ponctuels de vitesse et de température et du modèle PMV/PPD de Fanger. Les résultats montrent que les inserts lobés introduits dans le diffuseur, favorisent le mélange du jet qui en est issu avec l’air ambiant à traiter. Le confort thermique en zone d’occupation est amélioré de façon significative, par rapport au cas de référence du même diffuseur sans inserts. L’impact des inserts sur l’acoustique et les pertes de charges n’est pas significatif, ce qui valide l’innovation pour son application immédiate dans le bâtiment. En dernière partie, nous avons comparé la performance des diffuseurs innovants munis d’inserts lobés au diffuseur vortex, présenté sur le marché de la diffusion de l’air comme étant doté d’une grande capacité de mélange, suite à la mise en rotation du jet à l’aide d’ailettes profilées. Les résultats ont montré que l’encastrement au plafond du diffuseur vortex préconisé par le fabricant, dont il résulte l’adhérence immédiate du jet par effet Coanda, inhibe le mouvement de rotation escomptée, et sa performance dans ces conditions est inférieure à celle du diffuseur à inserts lobés. Il résulte de ce constat, la nécessité d’une installation du diffuseur vortex sur conduite apparente pour que sa performance soit réelle ; cela est envisageable pour des locaux commerciaux ou industriels de grande hauteur sous plafond. Les diffuseurs lobés encastrés au plafond, dont on a ainsi démontré la performance, sont parfaitement adaptés aux espaces de bureaux ou d’habitations de faibles hauteurs sous-plafond, et répondent par conséquent au réel besoin de la haute induction dans ce type de locaux. / This thesis deals with high-induction mixing ventilation for buildings using innovative air diffusers equipped with vortex promoters. These are lobed inserts, introduced into commercial air diffusers, without modifying the manufacturing process. The innovation was born from previous work and has recently been the subject of an European patent. The first objective of the present work is to conduct full scale experiments under typical heating and air conditioning conditions. By an experimental approach, the impact of the lobed inserts on the airflow and jet pattern, on the thermal comfort induced in the occupied zone of a thermally guarded climate chamber, and on the pressure drop and the noise generation. Airflow pattern is analyzed by large scale PIV 2D2C, and thermal comfort is evaluated in the occupied zone using a set of temperature and speed sensors and Fanger's PMV / PPD model. The results show that the lobed inserts introduced into the diffusers enhance the mixing between the jet and ambient air whose to be treated. The thermal comfort in the occupied zone is significantly improved, compared to the reference case of the same diffuser without inserts. The impact of the inserts on the acoustics and the pressure drop is not significant, which validates the innovation for its immediate application in buildings. Finally, we compared the performance of innovative diffusers with lobed inserts to the vortex diffuser, presented in the air diffusion market as a high mixing diffuser, because of the rotation generated by profiled fins. The results showed that when the diffuser is flush mounted to the ceiling, which is recommended by the manufacturer, the immediate attachment of the jet due to the Coanda effect inhibits the expected rotational movement. Its performance under these conditions is lower to that of the diffuser with lobed inserts. It follows from this finding that the installation of the vortex diffuser on a free pipe is necessary for its best performance ; this can be performed for high ceiling commercial buildings or industrial buildings. Ceiling flush mounted diffusers with lobed inserts, which we have demonstrated their performance, are perfectly suited for office spaces or homes with low ceiling heights, and therefore meet the real need for high induction in this type of buildings.
383

Parâmetros para o desenvolvimento de sapatilhas femininas de uso diário com ênfase no conforto térmico e percepção da usuária / Parameters for the Development of Daily Use Women Sneakers with emphasis in the Thermal Comfort and Wearer s Perception

Anselmo, Taiza Kalinowski 31 July 2014 (has links)
Made available in DSpace on 2016-12-12T20:17:55Z (GMT). No. of bitstreams: 1 118616.pdf: 3322963 bytes, checksum: 8c90d7f36cbfba744957ccedd7c6749a (MD5) Previous issue date: 2014-07-31 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / Research related to the thermal comfort in shoes has been bringing substantial technological advancements to the shoe sector. The present study aims to contribute the evaluation of the thermal comfort attribute of materials used in shoe manufacturing. During this development, qualitative and quantitative techniques were applied which contributed to the evaluation of the materials studied. Two volunteers participated in the present study where they tested five similar sneakers, manufactured with different types of lining materials being laminated synthetic polyurethane with viscose substrate, polyester, viscose and polyester mix, cacharrel and leather. Evaluated points: a) volunteers perception of heat and humidity thermal evaluation and easiness of wearing in a 1 to 10 scale; b) their perception in regards to the areas which present higher variation in thermal comfort; c) feet temperature variation from thermopairs readings (Digital Thermometer TD 890 with 4 channels); d) feet thermal radiation variation using thermographic camera (Eletrophysics PV 320 model). The measurement procedures were taken during a 30 min walk at 4km/h speed. The perception, the temperature and radiation evaluation were measured before and after the 30 min. walk. The qualitative research has appointed leather as the best performance material throughout the tests. The region, which presented the highest perception in heating and humidity increase perception, was the toes region. The highest increase in temperature occurred in the Viscose lined sneaker, with a general mean percentage of 13.16% for the thermo-pairs and of 14.03% for the thermographics. Leather had the best performance with a mean percentage of approximately 1%. Despite this difference, none of the materials was considered uncomfortable according to the ABNT/NBR 14837 table of the Level of Internal Shoe Temperature Comfort. All the materials used was considered comfortable with the exception of Viscose, which was considered normal/acceptable according to the table. / A pesquisa do conforto em calçados vem proporcionando avanços tecnológicos significativos para o setor calçadista. Este estudo procurou contribuir com a avaliação de materiais usados na confecção de calçados, que promovam conforto térmico. Ao longo do desenvolvimento, foram aplicadas técnicas qualitativas e quantitativas que contribuíram na avaliação destes materiais. Participaram do estudo duas voluntárias, que testaram cinco pares de sapatilhas similares, confeccionadas com diferentes materiais no forro, laminado sintético de poliuretano com substrato em viscose, poliéster, misto (viscose e poliéster), o cacharrel e o couro. Foram avaliados: a) a percepção das voluntárias quanto à avaliação térmica de aquecimento e umidade, e calce através de uma escala com pontuação de 1 a 10; b) a percepção das regiões que apresentaram maior alteração do conforto térmico; c) registro da variação de temperatura dos pés a partir de medidas com termopares (Termômetro Digital TD 890 com 4 canais); d) registro da variação da radiação térmica do pé utilizando câmera termográfica (Eletrophysics modelo PV 320). Os procedimentos de medidas, foram conduzidos ao longo de uma caminhada de 30 min a 4 km/h. A avaliação da percepção, temperatura e radiação foram medidas antes e depois da caminhada. A pesquisa qualitativa apontou, o couro como o material que apresentou maior desempenho ao longo dos testes. A região dos pés com maior percepção de aquecimento e umidade foram os dedos. O incremento de temperatura ocorreu principalmente na sapatilha com forro viscose, com uma média percentual geral de 13,16% para os termopares e 14,03% para a termografia. O couro teve o maior desempenho, com uma média percentual aproximadamente 1%. Apesar desta diferença, nenhum material foi considerado desconfortável, de acordo com a tabela do Nível de conforto da temperatura interna do calçado ABNT/NBR 14837. Todos os materiais foram considerados confortáveis, com exceção da viscose considerada de acordo com a tabela normal.
384

Método de avaliação de conforto térmico em órteses esportivas de joelho / Thermal Comfort Evaluation Method in Sports Knee Orthosis

Porto, Maetê da Costa 28 November 2014 (has links)
Made available in DSpace on 2016-12-12T20:17:56Z (GMT). No. of bitstreams: 1 120540.pdf: 27415901 bytes, checksum: e03c3666fff42b314d4f3ee99e734fb3 (MD5) Previous issue date: 2014-11-28 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / The present study aims to evaluate the temporal evolution of the temperature and humidity provided by different materials used in the lining of sports orthotics neoprene knee with the interface. This is a study of exploratory and descriptive and experimental nature, combined with quantitative and qualitative data collection methods and analysis of thermographic images approach. Measurements occurred in six alternate days in the morning. Identical orthoses made with smooth, neoprene lined on the outside with black polyamide fabric, with different liners (100 % polyester, 100 % polyamide, Emana® 270g, double frontura, Emana® 350g) and identical orthoses made from perforated neoprene lined were evaluated on the outside with black polyamide fabric and various lining (100 % polyester, 100 % polyamide, Emana® 270g, double frontura, Emana® 350g). Volunteers (men) were selected according to age, sex, BMI, duration of practice, hours of weekly practice, to have a physical integrity. For the tests used the same garments clo value. The instruments used were: a thermographic camera Eletrophysics model PV 320 and a precision scale BEL Engenering - Mark 160 - Class II. Temperature data were analyzed by thermography knees and moisture with the mass difference of bracing before and after the test. Of the materials tested, the combination of double polyester lining, perforated neoprene and nylon on the outside of the orthosis showed the best performance in knee - brace interaction. / O presente estudo tem por objetivo desenvolver um método para avaliar a evolução temporal da temperatura e umidade proporcionado por diferentes materiais utilizados no forro das órteses esportivas de neoprene com a interface do joelho. Trata-se de um estudo de cunho exploratório-descritivo e experimental, com abordagem combinada de métodos quantitativos e qualitativos de coleta e análise de imagens termográficas. As medições ocorreram em seis dias alternados no período da manhã. Foram avaliadas órteses idênticas confeccionadas com neoprene liso, forrado na parte externa com tecido poliamida preto, com diferentes forros: 100% poliéster, 100% poliamida, Emana® 270g, dupla frontura e Emana® 350g. Órteses idênticas confeccionadas com neoprene perfurado, também foram avaliadas, forradas na parte externa com tecido poliamida preto e diferentes forros:100% poliéster, 100% poliamida, Emana® 270g, dupla frontura e Emana® 350g. Os voluntários (homens) foram selecionados segundo a idade, sexo, IMC, tempo de prática, horas de treinos semanais, para ter uma integridade física. Para os testes utilizaram vestimentas com o mesmo valor em clo que é a unidade utilizada para medir o isolamento térmico das roupas. Os instrumentos de medida utilizados foram: uma Câmera Termografica Eletrophysics modelo PV 320 e uma balança de precisão BEL Engenering - Mark 160 - Classe ll. Foram analisados dados de temperatura através da termografia dos joelhos e a umidade com a diferença de massa da órtese antes e depois do ensaio. Dos materiais testados, a combinação forro de duplo poliéster, neoprene perfurado e a poliamida na parte externa da órtese apresentou o melhor desempenho na interação joelho-órtese.
385

Relação entre design da modelagem e aplicação de materiais de mudança de fase no vestuário : uma análise do conforto térmico com base nos fatores humanos

Santos, Roberta Machry Vianna dos 29 July 2015 (has links)
Made available in DSpace on 2016-12-12T20:17:57Z (GMT). No. of bitstreams: 1 123626.pdf: 3763667 bytes, checksum: d445fd671e6acd5feacf4ec380ef5c9d (MD5) Previous issue date: 2015-07-29 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / O presente estudo tem por objetivo investigar a existência de efeitos relacionados ao tipo de modelagem de camisetas fabricadas com tecidos que contenham fibras compostas por materiais de mudança de fase (PCM s) com a temperatura corporal, transpiração e percepção de conforto térmico. Para tal, foram combinados métodos quantitativos e qualitativos de coleta de dados e análise de imagens termográficas. Cinco voluntários aptos a realizar o procedimento experimental participaram do estudo, testando cada um três camisetas confeccionadas com tecido composto por 86% fio OLV ( 70% PES normal/30% Outlast® Viscose), 10% fio Outlast® PES filamento e 4% elastano, com gramatura de 140g/m2. As camisetas possuíam modelagens distintas: ajustada, tradicional ou ampla. O procedimento experimental consistiu em caminhada na esteira em velocidade moderada, de acordo com as aptidões de cada voluntário, por 20 minutos, seguido por 10 minutos de repouso, em ambiente climatizado. Avaliou-se durante o procedimento experimental: a) a percepção dos voluntários em relação à sensação térmica, de umidade e conforto geral durante o uso de cada uma das camisetas, utilizando a Escala Visual Analógica (VAS) em escala de 1 a 10; b) a percepção dos voluntários em relação à região superior do corpo em que sentiam maior desconforto em relação à sensação térmica e de umidade; c) a variação da temperatura durante o procedimento experimental mesurada através de termopares; d) a variação de transpiração; e e) a variação da radiação térmica das partes superiores do corpo através de imagens térmicas. As medidas foram coletadas durante o procedimento experimental. Os resultados indicam diferenças significativas entre a modelagem ajustada e a modelagem ampla nas regiões do peito e das costas, sendo que a modelagem ajustada possui uma maior variação entre as temperaturas iniciais e finais, porém constante entre as regiões do tórax. Durante o período de repouso, a modelagem ajustada mantém a temperatura estável até o final da avaliação, enquanto que as modelagens tradicional e ampla mantém a temperatura até aproximadamente o sétimo minuto, iniciando então a queda da temperatura. A avaliação subjetiva indica aumento de desconforto nos três itens analisados (sensação térmica, sensação de umidade e conforto geral), indicando maior desconforto durante o uso da modelagem ajustada.
386

Índice de conforto térmico, reações fisiológicas e desempenhos de tourinhos Sindi e Guzerá semiconfinados no Agreste Paraibano. / Indez thermal comfort, performance and physiological reactions of young bulls and Sindi and Guzerá semi-confined in Agreste Paraibano.

REGIS, John Emerson Ferreira. 14 June 2018 (has links)
Submitted by Johnny Rodrigues (johnnyrodrigues@ufcg.edu.br) on 2018-06-14T17:37:55Z No. of bitstreams: 1 JOHN EMERSON FERREIRA REGIS - DISSERTAÇÃO PPGEA 2008..pdf: 7356215 bytes, checksum: e9714e5a2f15594b75435e6c592f026b (MD5) / Made available in DSpace on 2018-06-14T17:37:55Z (GMT). No. of bitstreams: 1 JOHN EMERSON FERREIRA REGIS - DISSERTAÇÃO PPGEA 2008..pdf: 7356215 bytes, checksum: e9714e5a2f15594b75435e6c592f026b (MD5) Previous issue date: 2008-02 / Visa-se, com este estudo avaliar e estabelecer os índices de conforto térmico, as respostas termorreguladoras e desempenho de tourinhos Sindi e Guzerá semiconfinados, no período de julho a setembro de 2007, realizado na Estação Experimental de Alagoinha. pertencente à EMEPA-PB, no município de Alagoinha, região do Agreste Paraibano. Foram avaliadas as variáveis climáticas: temperatura do ar (TA), índice de temperatura de umidade (ITU), índice de temperatura de globo e umidade (ITGU). umidade relativa do ar (UR), temperatura de globo negro (TGN) e velocidade do vento (VV) e as variáveis fisiológicas analisadas foram: frequência respiratória (FR), temperatura retal (TR) e temperatura da pele (TP) e os índices produtivos: ganho de peso diário (GPD). ganho de peso total (GPT) e consumo de matéria seca (CMS). Utilizaram-se 16 bovinos: 8 de cada raça, e idade média de 30 ± 5 e 33 ± 3. do Sindi e Guzerá, respectivamente. Os índices ambientais foram medidos diariamente a cada duas horas (das 6 às 16 horas). Os índices de conforto ITU (77,5) e ITGU (78,6) estiveram, nos horários mais quentes, fora da zona de conforto térmico, atingindo níveis considerados críticos, mas as FR e TR se mantiveram dentro da normalidade para a espécie. O desempenho produtivo em ambas as raças permaneceu acima do esperado e as raças responderam satisfatoriamente às condições deste experimento, indicativo de uma boa resposta fisiológica. / The objective of this study was to evaluate and to establish the comfort indexes, the answers thermal regulate and acting of Sindi and Guzera semi confmed, in the period of july to september of 2007. Accomplished in the experimental station of Alagoinha. belonging EMEPA-PB, in the municipal city of Alagoinha, area of Agreste Paraibano. They were appraised the climatic variables: Temperature of the air (TA), Index of Temperature of Humidity (THI), Index of Temperature of Globe and Humidity (BGHI). Relative Humidity of the Air (RH), Temperature of Globe Black (TGN) and Air of the Wind (AW). Physiologic variables: respiratory rate (RR), Rectal Temperature (RT) and Skin Temperature (ST) and the productive indexes: Earnings of Daily (GPD) Weight. Earnings of Total (GPT) Weight and Consumption of Matter Dries (CM). 16 were used bovine: 8 of each race. With médium age of 30 ± 5 and 33 ± 3, of Sindi and Guzerá, respectively. The environmental indexes were measured daily every two hours (6 the 16 hours). The comfort indexes, THI (77,5) and BGHI (78,6). were. in the hottest schedules, out of the area of thermal comfort (ZCT), reaching leveis considered criticai, but RR and RT stayed inside of the normality for the species. The productive acting in both races was above the expected, the races answered the conditions of this experiment satisfactorily, being an indicative of good physiologic answer.
387

Conforto térmico e desempenho nos ambientes de ensino com inovações tecnológicas - estudo de multicasos no nordeste brasileiro

Torres, Manoel Geronimo Lino 07 April 2016 (has links)
Submitted by Leonardo Cavalcante (leo.ocavalcante@gmail.com) on 2018-06-06T12:02:25Z No. of bitstreams: 1 Arquivototal.pdf: 3264478 bytes, checksum: 742da63cecf21ce169225aebd5fea82e (MD5) / Made available in DSpace on 2018-06-06T12:02:25Z (GMT). No. of bitstreams: 1 Arquivototal.pdf: 3264478 bytes, checksum: 742da63cecf21ce169225aebd5fea82e (MD5) Previous issue date: 2016-04-07 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior - CAPES / Introduction: The global warming has severe environmental impacts and reach different areas and localities, in particular the least developed countries in the tropical region. In Brazil, the regions that suffer most impacts, with such changes will be the Amazon and Northeast. With the development of modern society, it is observed that individuals are consuming much of their time indoors, so, numerous studies have sought to study environmental comfort conditions to assist in the execution of activities and maximize human performance. One of the many changes that took place is in the learning environment, which is different compared to years ago. Technological resources in the classroom have made this a more versatile environment, allowing students and teachers to interact with other institutions, providing greater flexibility in the use of tools that extend their cognitive abilities. However, these tools can both facilitate communication and versatility of teaching and learning as increase the thermal load in the environment that already suffers direct influence of the external environment. In this sense, important to investigate how it is the variables of thermal comfort affect students' performance in climate-controlled learning environments provided these technologies. Objective: We analyzed the relationship between thermal comfort and performance of students in environments with technological innovations in areas of northeastern Brazil. Materials and Methods: Data were obtained during the experiments in the two institutions classrooms (A and B) of higher education located in Northeast Brazil. The Institution A is a private university in the city of João Pessoa- PB and the institution B is a public university in city of Teresina-PI. A total of 103 students of the engineering course participated, with one session per day, per class, on three consecutive days. The air temperature through the air conditioning was adjusted to 20ºC and 24ºC; the last day and is turned off the device to try to reach the value of 30 ° C. By heat stress meter TGD400 and microclimate station Babuc A, positioned in the center of the room recorded the parameters of the thermal environment. Cognitive abilities were assessed by the five events that make up the BPR-5 instrument, broken down for the three days of the experiment. Subjective and personal variables were evaluated in accordance with ISO7730/2005, through check list (thermal resistance of clothing) and scales of 4 points (Comfort) and 7 points (Sensation and Desire). With the results and data obtained were carried out simulations using the Generalized Linear Models (GLM) to verify the relationship between thermal comfort and performance. Results: At the institution A 42,9% of the first day of collection, where the temperature was in it 21,49ºC, indicated to be feeling slightly warm environment (+1) and 51,9% said that the place was comfortable (1). The PMV index of ISO7730/2005 indicated that the room was cold, with 57% of the vote between -1,5 and -2,5. On the second day, with an average temperature was 23,24ºC, about 58,1% of the students felt the thermally neutral environment (0) and 55,4% rated it as comfortable (1). The PMV index, on the second day, indicated that the room was slightly cold, with 87,8% of the vote between -0,5 and -1,5. On the third day the mean temperature was 27,49ºC and 41,9% of the rated as hot environment (+2) and finally, 35.1% VII of the evaluated local rated as slightly uncomfortable (2). The Middle Foretold vote indicated that the room was slightly hot on the third day, with 60.8% of votes ranging from +0,5 to +1,5. The institution B, on the first day of collection whose average temperature was 20,07ºC, about 50% of students reported feeling that the environment was slightly cold (-1) and 61.5% of students rated the environment as comfortable (1). The PMV index indicated that the environment was cold with 92% of the vote results were between -1,5 and -2,5. On the second day the average temperature was 33,72ºC and 59,3% of students said they felt the warm environment (+2) and 66,7% rated it as uncomfortable (3). Regarding the PMV 100% of the frequency of the votes indicated that the environment was rated as very hot (PMV> +2.5). On the third day with the average temperature 22,95ºC, about 73,3% of the students indicated that the thermal sensation was neutral (0) and the place was rated by 96,2% of the students as comfortable (1). The PMV index showed that 88,5% of the calculated votes of the students indicated that the site was slightly cold (-0,5 <PMV <-1,5). Using Generalized Linear Models, in particular the Ordinal Regression, was observed from the data of the two institutions, the performance is linked to subjective criteria, in particular the thermal sensation and the globe temperature. It was observed that the rise globe temperature in 1 ° C increases the chance of students pass a performance range lower to a higher 34% for situations where the wind chill is indicated as very hot. Final considerations: This study showed that there is a difference between what the standard ISO7730/2005 predicts what is actually reported by students in areas of the Brazilian Northeast, ie situations where the standard indicates discomfort students report being comfortable. It was also observed that subjective variables are important factors for a good cognitive performance of students. / Introdução: O aquecimento global recente tem impactos ambientais intensos e atingirá diversas áreas e localidades, em especial, os países menos desenvolvidos situados na região tropical. No Brasil, as regiões que mais sofrerão impactos, com tais mudanças, serão a Amazônia e o Nordeste. Com o desenvolvimento da sociedade moderna, observa-se que os indivíduos estão consumindo grande parte do seu tempo em ambientes fechados, e por isso, numerosas pesquisas vêm buscando estudar condições de conforto ambiental que auxiliem na execução das atividades e maximização do desempenho humano. Uma das diversas mudanças que ocorreram, encontra-se no ambiente de ensino, o qual é diferente quando comparado ao de anos atrás. Recursos tecnológicos em sala de aula têm tornado este ambiente mais versátil, permitindo que alunos e professores interajam com outras instituições, conferindo maior flexibilidade na utilização de ferramentas que estendem suas habilidades cognitivas. Nesse sentido, torna-se importante investigar como as variáveis do conforto térmico afetam o desempenho dos alunos em ambientes de ensino climatizados providos destas tecnologias. Objetivo: Analisar a relação entre conforto térmico e o desempenho de estudantes nos ambientes com inovações tecnológicas em áreas do nordeste brasileiro. Materiais e Métodos: Os dados foram obtidos durante a realização dos experimentos nas salas de aula de duas instituições (A e B) de ensino superior localizadas no Nordeste brasileiro. A instituição A é uma universidade privada e encontra-se na cidade de João Pessoa- e a instituição B é uma universidade publica e encontra-se na cidade de Teresina. No total de 103 alunos dos cursos de exatas das duas instituições participaram, sendo uma sessão por dia, por turma, em três dias consecutivos. A temperatura do ar, através do ar condicionado, foi ajustada para 20ºC e 24ºC; no último dia desligou-se o aparelho para tentar se chegar ao valor de 30°C. Através do medidor de estresse térmico TGD400 e estação microclimática Babuc A,posicionados no centro da sala, registraram-se os parâmetros do ambiente térmico. As habilidades cognitivas foram avaliadas pelas cinco provas que compõem o instrumento do BPR-5, decomposto para os três dias de experimento. As variáveis subjetivas e pessoais foram avaliadas de acordo com ISO7730/2005, através de check list (resistência térmica das vestimentas) e escalas de 4 pontos (Conforto) e 7 pontos (Sensação e Desejo). Com os resultados e dados obtidos realizaram-se simulações através dos Modelos Lineares Generalizados (MLG) para se verificar a relação entre conforto térmico e desempenho. Resultados: Na instituição A 42,9% dos alunos no primeiro dia de coleta, onde a temperatura encontrava-se a 21,49ºC, indicaram estar sentindo o ambiente levemente quente (+1) e 51,9% avaliaram que o local estava confortável (1). O índice PMV da ISO7730/2005 indicou que o ambiente estava frio, com 57% dos votos entre -1,5 e -2,5. No segundo dia, cuja temperatura média foi de 23,24ºC, cerca de 58,1% dos alunos sentiram o ambiente termicamente neutro (0) e 55,4% classificaram-no como confortável (1). O índice PMV, no segundo dia, indicou que o ambiente estava levemente frio, com 87,8% dos votos entre -0,5 e -1,5. No terceiro dia a temperatura média foi de 27,49ºC e 41,9% dos alunos classificaram o ambiente como quente (+2) e por fim, 35,1% dos avaliados classificaram o local como levemente desconfortável (2). V O Voto Médio Predito indicou que o ambiente estava levemente quente no terceiro dia, com 60,8% dos votos variando de +0,5 a +1,5. Na instituição B, no primeiro dia de coleta cuja temperatura média foi de 20,07ºC, cerca de 50% dos estudantes indicaram sentir que o ambiente estava levemente frio (-1) e 61,5% dos alunos classificaram o ambiente como confortável (1). O índice PMV indicou que o ambiente estava frio com 92% dos resultados obtidos dos votos estavam entre -1,5 a -2,5. No segundo dia a temperatura média foi de 33,72ºC e 59,3% dos alunos afirmaram que sentiam o ambiente quente (+2) e 66,7% classificaram-no como desconfortável (3). Em relação ao PMV 100% da frequência dos votos indicaram que o ambiente foi classificado como muito quente (PMV> +2,5). No terceiro dia com a temperatura média de 22,95ºC, cerca de 73,3% dos estudantes indicaram que a sensação térmica era neutra (0) e o local foi classificado por 96,2% dos alunos como confortável (1). O índice PMV mostrou que 88,5% dos votos calculados dos alunos, indicaram que o local estava levemente frio (-0,5<PMV<-1,5). Utilizando Modelos Lineares Generalizados, em especial a Regressão Linear Ordinal, observou-se através dos dados das duas instituições, que o desempenho está ligado aos parâmetros subjetivos, em especial a sensação térmica e a temperatura de globo. Foi observado que ao se elevar a temperatura de globo em 1ºC aumenta-se a chance dos estudantes passarem de uma faixa de desempenho inferior para uma superior em 34%, para situações onde a sensação térmica é indicada como muito quente. Considerações finais: Este estudo mostrou que existe uma diferença entre o que a norma ISO7730/2005 prediz com o que realmente é relatado pelos estudantes, de áreas da região do nordeste brasileiro, ou seja, situações em que a norma indica desconforto os estudantes relatam estar confortáveis. Observou-se também que as variáveis subjetivas são fatores importantes para um bom desempenho cognitivo dos estudantes.
388

Evaluation of retrofitting strategies for post-war office buildings

Duran, Ozlem January 2018 (has links)
The energy used in non-domestic buildings accounts for 18 % of the energy use in the UK. Within the non-domestic building stock, 11 % of office buildings have a very high influence on the energy use. Thus, the retrofit of office buildings has a significant potential for energy efficiency and greenhouse gas emissions reduction within the non-domestic building stock. However, the replacement rate of existing buildings by new-build is only around 1-3 % per annum. Post-war office buildings, (built between 1945 and 1985) represent a promising sector for retrofit and energy demand reduction. They have disproportionately high energy consumption because many were built before the building regulations addressed thermal performance. The aim of the research is to evaluate the retrofit strategies for post-war office buildings accounting for the improved energy efficiency, thermal comfort and hence, productivity, capital and the running costs. The research seeks to provide the optimal generic retrofit strategies and illustrate sophisticated methods which will be the basis for guidelines about post-war office building retrofit. For this, multiple combinations of heating and cooling retrofit measures were applied to representative models (Exemplar) of post-war office buildings using dynamic thermal simulation modelling. The retrofit strategies include; applying envelope retrofit to UK Building Regulations Part L2B and The Passivhaus Institue EnerPHit standards for heating demand reduction and winter comfort. Passive cooling interventions such as shading devices and night ventilation and active cooling intervention such as mixed-mode ventilation were applied to overcome summer overheating. All retrofit combinations were evaluated considering future climate, inner and outer city locations and different orientations. In summary, the results showed that under current weather conditions Part L2B standard retrofit with passive cooling provided the optimum solution. In 2050, however, both Part L2B retrofit naturally ventilated cases with the passive cooling measures and EnerPHit retrofit mixed-mode ventilation cases provide the requisite thermal comfort and result in a similar range of energy consumption. It was concluded that to create generic retrofit solutions which could be applied to a given typology within the building stock is possible. The methodology and the Exemplar model could be used in future projects by decision-makers and the findings and analysis of the simulations could be taken as guidance for the widespread retrofit of post-war office buildings.
389

Avaliação do desempenho da ventilação natural e do sombreamento em casas de Maceió projetadas segundo princípios abordados na cartilha de Armando de holanda / Perfomance evaluation of natural ventilation and shading of houses in Maceió designed according to principles discussed in the Armando de Holanda s booklet

Castro, Renata Torres Sarmento de 25 November 2011 (has links)
This survey deals with the dimensionality of the natural ventilation and its fitness to building houses in the Brazilian Northeast. It is a case study due to the limited sample of the object evaluated, since that its abridgement involved only two houses located in Maceió city in the state of Alagoas. As matter of fact, by the end of 1970 through 1980, a pernambucano architect under the name of Armando de Holanda wrote a booklet guide containing 9 (nine) bioclimatic strategies to solve the problem of the hot and damp ventilation that reaches the tropical regions causing distress to their inhabitants, above all inside the houses. According to Holanda s point of view the trouble could be lessened if the building of the houses were more adequate and suitable to the local temperature of the environment. The statements lined out by Holanda consisted of nine (9) strategic. In the inquiry made up, some of Holanda s a priori strategic propositions have been selected and evaluated such the natural air performance, the shading and other items of two houses built by two architects who drew and carried out an experimental project for their own dwellings. Both houses were object of analysis and evaluation by means of a detailed methodoly concerning the climatic data and the bioclimatic strategies followed by an essay of ventilation and sunny rays with virtual models through computerized SketchUp application of the solar chart. As a result, the house 1 (one) showed up efficient average of natural ventilation and shading, while the house 2 (two) attested the average and positive performance of natural ventilation as well as shading. Yet in both houses the direct observation registered adequate bioclimatic strategies, but some determined solutions seemed inadequate to a hot and damp climate as inward divisions no evidence of eaves. Hypothetically the conclusion is that Holanda s guidance may cause good effect when well fitted, in spite of being necessary some practical experiments to assure thermal comfort to the buildings situated in hot and damp regions, with the adoption of the suggested methodoly and good tools of evaluation preceded by an architectonic planning. / Fundação de Amparo a Pesquisa do Estado de Alagoas / A tradição construtiva luso-brasileira, como ilustram as tradicionais casas de fazenda, e o modernismo dos anos de 1950-1970, como as casas modernistas urbanas, adotavam a preocupação com a ventilação natural e a proteção solar no trópico quente e úmido. Na década de 1970, o arquiteto pernambucano Armando de Holanda desenvolveu o Roteiro para Construir no Nordeste, reunindo nove estratégias bioclimáticas. Para o clima quente e úmido do Nordeste brasileiro, com temperaturas amenas durante quase todo o ano, as principais estratégias de projeto para promover conforto térmico resumem-se em permitir o escoamento da ventilação natural no interior das edificações e promover o sombreamento das fachadas e aberturas. Contudo, com o intensivo desenvolvimento dos conhecimentos em conforto ambiental no Brasil, estima-se que a adoção exclusiva dessas estratégias, sem experimentos práticos, não é suficiente para garantir a eficiência da edificação, necessitando, portanto, da adoção conjunta de métodos de avaliação de desempenho ambiental. O objetivo dessa pesquisa de mestrado em arquitetura e urbanismo é avaliar o desempenho da ventilação natural e do sombreamento de casas projetadas segundo os princípios abordados na cartilha de Armando de Holanda. Avaliaram-se duas casas construídas em Maceió/AL, entre final de 1970 e início de 1980, projetadas por arquitetos e professores da Universidade Federal de Alagoas. A metodologia proposta compreendeu: detalhamento de dados climáticos e estratégias bioclimáticas para Maceió; visitas às residências, levantamentos arquitetônicos, análise bioclimática; entrevistas com os arquitetos/moradores das casas; realização de ensaios de ventilação, no equipamento mesa d´água com maquetes vazadas, e de insolação com modelos virtuais, no programa de computador SketchUp e aplicação da carta solar. Constatouse médio desempenho de ventilação natural e de sombreamento na Casa 1; e médio e positivo desempenho de ventilação natural e de sombreamento, respectivamente, na Casa 2. Verificouse a utilização de adequadas estratégias bioclimáticas nas casas, porém destacaram-se determinadas soluções inadequadas para o clima quente e úmido, como a compartimentação interna e a ausência de beirais. Conclui-se pelos adequados princípios bioclimáticos do Roteiro, porém pela necessidade de experimentos práticos para garantir conforto térmico às edificações de forma a prever as deficiências e solucioná-las. Sugere-se a aplicação da metodologia proposta e das ferramentas de avaliação em pesquisas e planejamento arquitetônico para possibilitar maior garantia de desempenho térmico nas edificações, localizadas em regiões de clima quente e úmido.
390

Ilha de calor e a influência no conforto térmico da região integrada de desenvolvimento da grande Teresina (ride). / Heat island and the influence in the thermal comfort of the intefrated region of development of the grande Teresina (ride)

Santiago, Dimas de Barros 19 April 2017 (has links)
The urban heat islands are effects where the temperature of the urban areas is greater than the surrounding areas and rural areas, as a result of the modification and/or substitution of the vegetation by areas ithout vegetation or asphaltic areas, modifying the ambient climate and the local human thermal comfort , The aim of the study was to observe the phenomenon of the Islands of Urban Heat (ICU) in Teresina-PI and Timon-MA and the relation with thermal comfort of the study area, through thermal remote sensing and the human thermal comfort index , Effective Temperature. Six satellite images were used, four obtained by Landsat-5 TM satellite, acquired in the Catalog of Images - DGI - INPE and two obtained from Landsat-8 on the USGS website. The images correspond to the passage of the satellite at points 219, orbits 63 and point 219, orbit 64 dates, Landsat 5: 20 June 2004, 10 June 2006, 01 July 2008, 01 July 2008. Landsat 8: July 18, 2014 and July 23, 2016. Hourly, daily and monthly data of relative air humidity and average air temperature, for the years of study, provided by the National Institute of Meteorology (INMET), for the calculation of the Human Thermal Comfort Index. For the image processing, models were developed using the Model Maker tool of the ERDAS Imagine 9.2 program and Qgis 2.12.1, having images necessary to obtain the temperature on the terrestrial surface, which will serve as the basis for the identification of the heat islands and the Effective temperature index, to observe the comfort of the cities under study. In the study, we observed the temperature difference between the Teresina-PI and Timon-MA cities and areas without urbanization (more vegetated, without soil modification), where there was a variation between approximately 6 ° C and 9 ° C, When compared surrounding areas and the city. The relationship between heat islands and human thermal comfort was thus concluded, as cities develop and occur at surface modification, temperatures increase, consequently human discomfort increases, since the human being is influenced by the In which he lives. / Conselho Nacional de Desenvolvimento Científico e Tecnológico / As ilhas de calor urbanas são efeitos onde a temperatura das áreas urbanas são maiores que as áreas próximas e áreas rurais, consequência da modificação e/ou substituição da vegetação por áreas sem vegetação ou áreas asfálticas, modificando o clima ambiente e o conforto térmico humano local, assim o objetivo do trabalho visou observar o fenômeno Ilhas de Calor Urbanas (ICU), em Teresina-PI e Timon-MA e a relação com conforto térmico da área de estudo, por meio do sensoriamento remoto termal e do Índice de conforto térmico humano, Temperatura Efetiva. Foram utilizadas seis imagens de satélites, quatro obtidas pelo satélite Landsat-5 TM, adquiridas no Catálogo de Imagens - DGI - INPE e duas obtidas do Landsat-8 no site da USGS. As imagens correspondem à passagem do satélite nos pontos 219, órbitas 63 e ponto 219, órbita 64 datas, Landsat 5: 20 de Junho de 2004, 10 de Junho de 2006, 01 de Julho de 2008, 01 de Julho de 2008. Landsat 8: 18 de Julho de 2014 e 23 de Julho de 2016. Dados horários, diários e mensais de umidade relativa do ar e temperatura média do ar, para os anos de estudo, cedidos pelo Instituto Nacional de Meteorologia (INMET), para o cálculo do Índice de Conforto Térmico Humano. Para o processamento das imagens foram desenvolvidos modelos através da ferramenta Model Maker do programa ERDAS Imagine 9.2 e o Qgis 2.12.1, tendo imagens necessárias para a obtenção da temperatura na superfície terrestre, que servirá como base para a identificação das ilhas de calor e o índice de temperatura efetiva, para observar o conforto das cidades em estudo. No estudo observou-se a diferença de temperatura entre a área das cidades de Teresina-PI e Timon-MA e as áreas sem urbanização (mais vegetada, sem modificação do solo), onde houve uma variação entre aproximadamente 6°C a 9°C, quando comparado áreas circunvizinhas e a cidade. Concluiu-se assim a relação entre as ilhas de calor e o conforto térmico humano, assim à medida que as cidades se desenvolvem e ocorre à modificação da superfície, as temperaturas aumentam, consequentemente aumenta o desconforto humano, visto que o ser humano sofre influência do meio em que vive.

Page generated in 0.3301 seconds