• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 36
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 39
  • 39
  • 39
  • 19
  • 12
  • 12
  • 9
  • 9
  • 8
  • 7
  • 6
  • 6
  • 4
  • 4
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Preservação de efluentes para analise de carbono organico dissolvido

Galrão, Divanildes da Silva 03 August 2018 (has links)
Orientadores: Jose Roberto Guimarães / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Civil / Made available in DSpace on 2018-08-03T19:05:03Z (GMT). No. of bitstreams: 1 Galrao_DivanildesdaSilva_M.pdf: 1700452 bytes, checksum: 00008e31bdce85af5b908dfa92cf19fd (MD5) Previous issue date: 2003 / Mestrado
12

Segurança e higiene no trabalho em estação de tratamento de esgoto

Buda, José Francisco, 1959- 03 August 2018 (has links)
Orientadores: Roberto Feijo de Figueiredo, Bruno Coraucci Filho / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Civil / Made available in DSpace on 2018-08-03T21:52:51Z (GMT). No. of bitstreams: 1 Buda_JoseFrancisco_M.pdf: 1302890 bytes, checksum: f31d7feac427c2f9ee077d9389fb1e3c (MD5) Previous issue date: 2004 / Mestrado
13

Detecção de cistos de giardia spp. e oocistos de cryptosporidium spp. e caracterização da microfauna na água bruta das estações de tratamento de água no município de Blumenau, SC /

Grott, Suelen Cristina, 1984-, Goulart, Juliane Araújo Greinert, 1977-, Universidade Regional de Blumenau. Programa de Pós-Graduação em Engenharia Ambiental. January 2015 (has links) (PDF)
Orientador: Juliane Araújo Greinert Goulart. / Dissertação (Mestrado em Engenharia Ambiental) - Programa de Pós-Graduação em Engenharia Ambiental, Centro de Ciências Tecnológicas.
14

Uso de lodo de estações de tratamento de água e de esgoto urbano como condicionador de solo, com ênfase nas propriedades físicas do solo /

Colino, Marcelo de Marchi, 1980- January 2006 (has links)
Orientador: Raimundo Leite Cruz / Banca: Iraê Amaral Guerrini / Banca: Marcelo Zaiat / Resumo: O lodo proveniente das estações de Tratamento de Água e Esgoto Urbano é um material volumoso que sobra nas estações, causando vários transtornos e problemas de ordem ambiental. O emprego deste material, rico em matéria orgânica, na agricultura, é ao que parece a proposta mais viável. O objetivo deste trabalho foi estudar as mudanças nas propriedades físicas de dois tipos de solos, um de textura fina (latossolo roxo) e outro de textura grossa (areia quartzosa), após incorporação de três tipos de lodos provenientes do tratamento de água e de esgoto urbano. As variáveis avaliadas foram os índices físicos (massa específica, massa específica aparente seca, massa específica dos solos, massa específica saturada, massa específica submersa, umidade, porosidade e índices de vazios), condutividade hidráulica de solo saturado e a curva de retenção de água no solo. Adotou-se o delineamento de blocos ao acaso, em esquema fatorial 2 x 3 x 2 x 3 x 3, sendo 2 tipos de solo, 3 tipos de lodo, 2 qualidades de água, 3 épocas de amostragem com 3 repetições de cada amostra. Os resultados mostram que nas condições abordadas, os lodos produzido pelas Estações de Tratamento de Água e Esgoto Urbano, podem ser utilizados na agricultura, como condicionadores de solo, levando a melhoria nas características físicas do solos avaliados neste experimento. / Abstract: The silt proceeding from the stations of Treatment of Water and Urban Sewer is a voluminous material that surplus in the stations, causing some upheavals and problems of ambient order. The use of this material, rich in organic substance, in the agriculture, is to that seems the proposal most viable. The objective of this work was to study the changes in the physical properties of two types of soil, one of fine texture and another one of thick texture, after incorporation of three types of silts proceeding from the treatment of water and urban sewer. 3 The delineation of blocks to perhaps was adopted, in factorial project 2 x 3 x 2 x 3 x 3, being 2 types of soil, 3 types of silt, 2 qualities of water, 3 times of sampling with 3 repetitions of each sample. The results show that in the boarded conditions, the silt produced per the Stations of Water Treatment and Urban Sewer, can be used in agriculture, as soil conditioning, taking the improvement in the physical characteristics of ground evaluated in this experiment. / Mestre
15

Uso urbano não potável de efluentes de estações de tratamento de esgoto sanitário : estudo de caso : município de Campo Largo - PR / Simone Soares Göhringer ; orientador, Miguel Mansur Aisse

Göhringer, Simone Soares January 2006 (has links)
Dissertação (mestrado) - Pontifícia Universidade Católica do Paraná, Curitiba, 2006 / Inclui bibliografia / O uso de efluentes de Estações de Tratamento de Esgoto em locais onde sejam admitidas águas de qualidade inferior, além de mitigar a poluição hídrica, surge como uma proposta de disponibilizar esta mesma quantidade ao abastecimento potável, proporcionando
16

Remoção do herbicida 2,4 diclorofenoxiacético (2,4-D) no tratamento convencional de água e associado à adsorção em carvão ativado em pó (CAP) em escala piloto

Guerra, Jacquelinne Fantin 09 July 2014 (has links)
Submitted by Maykon Nascimento (maykon.albani@hotmail.com) on 2016-03-07T19:08:02Z No. of bitstreams: 2 license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) Dissertacao Jacqueline Fantim Guerra.pdf: 1120963 bytes, checksum: 1f18ee1cfc106536de0c288a2b0acef6 (MD5) / Approved for entry into archive by Patricia Barros (patricia.barros@ufes.br) on 2016-03-08T15:36:24Z (GMT) No. of bitstreams: 2 license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) Dissertacao Jacqueline Fantim Guerra.pdf: 1120963 bytes, checksum: 1f18ee1cfc106536de0c288a2b0acef6 (MD5) / Made available in DSpace on 2016-03-08T15:36:24Z (GMT). No. of bitstreams: 2 license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) Dissertacao Jacqueline Fantim Guerra.pdf: 1120963 bytes, checksum: 1f18ee1cfc106536de0c288a2b0acef6 (MD5) Previous issue date: 2014 / O aumento do uso de agrotóxicos no Brasil tem causado muitas preocupações, tanto em relação à questão ambiental quanto a saúde pública. Muitos desses compostos não são eficientemente removidos das águas por tratamento convencional, sendo necessárias alternativas que os removam das águas de abastecimento. Dentre as tecnologias existentes, a adsorção em CAP é considerada uma das mais efetivas e confiáveis, cujas vantagens incluem alta eficiência de remoção e facilidade de operação. O objetivo desta pesquisa é avaliar a remoção, em escala piloto, do agrotóxico 2,4-D e o seu principal metabólito 2,4-DCP em amostras de águas tratadas por adsorção em CAP associado ao tratamento convencional. Os testes foram realizados em instalação piloto na áreada ETA Carapina/CESAN. A água bruta foi a proveniente do rio Santa Maria da Vitória contaminadaatravés da adição de agrotóxico em sua fórmula comercial. Foram realizados quatro ensaios, dois sem adição de CAP e dois com adição de CAP junto à unidade de mistura rápida. Os agrotóxicos foram detectados e quantificados através da cromatografia líquida de alta eficiência, em metodologia validada. As amostras coletadas foram caracterizadas de acordo com os parâmetros: temperatura, turbidez, condutividade elétrica, absorbância em 254 nm, cor real, cor aparente, alcalinidade, carbono orgânico total, além e concentração dos agrotóxicos 2,4-D e ácido 2,4,5-T e do metabólito 2,4-DCP. Os diferentes ensaios foram avaliados em termos da taxa de remoção destes parâmetros. Como resultado no TCVcom adição de CAP o composto de interesse foi removido abaixo de 30 μg. L-1,Valor Máximo Permitido, estabelecido pela Portaria do MS n° 2.914/2011 para dosagem de 100μg.L-1e mostrou-se eficiente, também, na remoção de matéria orgânica. Em nenhum dos testes foi detectado o composto 2,4-DCP e 2,4,5-T. / The increased use of pesticides in Brazil has caused many concerns, both in relation to environmental issues as public health. Many of these compounds are not efficiently removed by conventional water treatment, alternatives necessary to remove the water supply being. Among the existing technologies adsorption in PAC is considered one of the most effective and reliable, whose advantages include high removal efficiency and ease of operation. The objective of this research is to evaluate the removal in pilot scale, the pesticide 2,4-D and its major metabolite 2,4-DCP in water samples treated by adsorption on PAC associated with TCV. The tests were conducted in a pilot plant in the area of Carapina ETA / CESAN. The raw water from the river was the Santa Maria da Vitoria purposely contaminated by the addition of pesticides in its commercial formula. Four trials, two without addition of PAC and two addition with the cap unit rapid mixing were performed. The pesticides were detected and quantified by high performance liquid chromatography-effectiveness, validated methodology. The samples were characterized according to the parameters: temperature, turbidity, conductivity, absorbance at 254 nm, actual color, apparent color, alkalinity, total organic carbon, addition and concentration of the pesticide 2,4- D and 2,4,5-T and 2,4-DCP metabolite. The different assays were assessed in terms of the rate of removal of these parameters. As a result the addition of PAC with treatment conventional the compound of interest was removed below 30 μ.L-1 Maximum Value Allowed, established by Ordinance of the Ministry of Health n ° 2.914/2011 for dosage of 100 μ.L-1 and showed It is also effective in removing organic material. In none of the tests the compound 2,4-DCP and 2,4,5-T was detected.
17

Automação no controle de perdas e redução de impactos ambientais em sistemas de abastecimento de água

Votre, Rodrigo 22 January 2015 (has links)
Orientadora : Profª. Drª. Daniela Neuffer / CoorientadorA : Profª. Drª. Tânia Mara Pereira Marques / Dissertação (mestrado) - Universidade Federal do Paraná, Setor de Tecnologia, Programa de Mestrado Profissional em Meio Ambiente Urbano e Industrial/ SENAI/ Universität Stuttgart. Defesa: Curitiba, 05/08/2014 / Inclui referências / Resumo: O conhecimento sobre os processos dos sistemas de abastecimento de água (SSA's), dos tipos e perdas existentes no abastecimento de água e das ferramentas de automação, são essenciais para o entendimento das possibilidades de melhorias do desempenho desses sistemas. No saneamento, os principais atrativos para se justificar o investimento em automação residem na melhoria da qualidade do tratamento e distribuição de água, por meio do monitoramento e controle em tempo real, redução de custos operacionais, como produtos químicos e substituição da operação nas unidades por operação remota, além da possibilidade de gerenciamento de energia elétrica consumida, de medições precisas dos volumes de água produzida e distribuída e do controle das variáveis de processo, como pressão, nível e vazão. Entretanto as maiores dificuldades encontradas em um (SSA), residem na quantidade de água perdida e no impacto ambiental gerado, tanto na necessidade de construção de novos sistemas de abastecimento, como nos danos provocados por vazamentos e rompimentos. Para redução destes fatores, foi proposto um estudo de caso avaliativo em um sistema de abastecimento da SANEPAR em Curitiba - PR, Centro de Reservação (CR) Portão, antes e após o advento da automação, visando validar o controle de pressão automatizada via set point de pressão, que possibilitam o controle da variação de velocidade dos conjuntos moto bomba (CMB's) acionados por conversores de frequência. Ao se controlar a pressão num segmento da rede com o uso de conversores de frequência, quando as pressões tendem a aumentar nos pontos críticos, os conversores de frequência se ajustam ao set point de pressão do Controlador Lógico Programável (CLP), variando a velocidade dos CMB's, buscando manter a pressão requerida, ligando ou desligando bombas complementares. Este estudo de caso demonstrou o ganho proporcionado pelo controle de pressão automatizado, tanto na redução de perdas de água, redução de manutenções nas redes de distribuição, como na redução do gasto de energia elétrica e visa a melhoria continua dos processos, colaborando para otimizar o sistema de abastecimento, minimizando possíveis falhas, danos ambientais e financeiros. Palavras-chave:CLP,SSA,CMB,CR,set point,telemetria / Abstract: The knowledge about the processes of water supply systems (WSS's), and types of existing losses in water supply and automation tools are essential for understanding the possibilities for improvement of the performance of these systems. In sanitation, the main attractions to justify the investment in automation reside in improving the quality of treatment and distribution of water, through monitoring and control in real time, reducing operational costs, such as chemicals and replacement of operating units by remote operation, and the possibility of managing electricity consumed, accurate measurements of the volume of water produced and distributed, and control of process variables such as pressure, level and flow. However the greatest difficulties encountered in one (WWS), reside in the amount of water lost and the environmental impact, both in the need to build new supply systems, as the damage from leaks and ruptures. To reduce these factors, we propose an evaluative case study in SANEPAR water suply system, Curitiba - PR, Center Reservation (CR) Portão, before and after the advent of automation, aimed at validating the automated pressure control with set point pressure, enabling control of the speed variation of the motor pump sets (MPS's) driven by frequency converters. By controlling the pressure in a network segment using frequency converters, when pressures tend to increase the critical points, frequency converters adjust the set point pressure of Programmable Logic Controller (PLC), varying the speed of MPS's, seeking to maintain the required pressure by turning on or turning off additional pumps. This case study demonstrated the gain provided by the automated pressure control, either to reduce water losses, reduction of maintenance in distribution networks, such as the reduction of the electric power source and aims at continuous improvement of processes, helping to optimize supply system, minimizing potential failures, environmental and financial damage. Keywords: CLP, WSS, MPS, CR, set point, telemetry
18

Estudo de viroma em água de esgoto influente e efluente na estação de tratamento de esgoto norte em Brasília

Moriya, Nataly Mitie Natsume 01 March 2018 (has links)
Dissertação (mestrado)—Universidade de Brasília, Instituto de Biologia, Pós-Graduação em Biologia Microbiana, 2018. / Submitted by Raquel Viana (raquelviana@bce.unb.br) on 2018-07-20T17:33:47Z No. of bitstreams: 1 2018_NatalyMitieNatsumeMoriya.pdf: 2644950 bytes, checksum: ea481d769cf8a761af43566c542d198a (MD5) / Approved for entry into archive by Raquel Viana (raquelviana@bce.unb.br) on 2018-07-20T19:34:41Z (GMT) No. of bitstreams: 1 2018_NatalyMitieNatsumeMoriya.pdf: 2644950 bytes, checksum: ea481d769cf8a761af43566c542d198a (MD5) / Made available in DSpace on 2018-07-20T19:34:41Z (GMT). No. of bitstreams: 1 2018_NatalyMitieNatsumeMoriya.pdf: 2644950 bytes, checksum: ea481d769cf8a761af43566c542d198a (MD5) Previous issue date: 2018-07-20 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES). / A contaminação por patógenos humanos na água de esgoto é um assunto importante, principalmente em locais onde as condições de saneamento não são ideais. A tecnologia de Next Generation Sequencing (NGS) tem sido utilizada em diversos estudos metagenômicos virais (viromas). Além de descrever a diversidade genética, é uma ferramenta útil para analisar o viroma em amostras de esgoto. Apesar do interesse no tratamento de água, a cidade de Brasília não possuí um estudo de censo e informações focado na contaminação viral do Lago Paranoá. Com este propósito, os patógenos humanos astrovírus (HAstV), norovírus (NoV) e sapovírus (SaV) foram selecionados e investigados em amostras de água não-tratada (influente) e tratada (efluente) utilizando o NGS. Amostras de influente e efluente (de março, maio de 2016 e fevereiro de 2017) foram coletadas na estação de tratamento de água de esgoto em Brasília, Brasil. As amostras foram submetidas a processos de extração de RNA e as bibliotecas de cDNA foram sequenciadas através do Illumina HiSeq 2000, com a condição de 100 bases paired-end. Os reads foram trimados através do Trimmomatic e os contigs foram montados com os programas Megahit e Velvet. As sequências foram analisadas por tBLASTX e Megablast, respectivamente, contra o "RefSeq Virus" utilizando o software Geneious v.8.1. Os reads resultantes também foram enviados e analisados na plataforma online Kaiju. Os SaV foram detectados nas seis amostras sequenciadas, HAstV e NoV foram encontrados em todas as amostras, exceto no efluente de maio. Os resultados encontrados foram discutidos e comparados com estudos brasileiros e internacionais. / Contamination of human pathogen in wastewater is an important matter, especially where sanitation is not ideal condition. Next Generation Sequencing (NGS) has been applied in several viral metagenomes (viromes) studies. Besides describing gene diversity, it is a helpful tool to analyze virome in sewage water. Despite the interest in wastewater treatment, Brasilia city lacks a census study and information aiming to assess viral contamination in Paranoa lake. For this purpose, the human pathogens astrovirus (HAstV), norovirus (NoV) and sapovirus (SaV) were selected in untreated (influent) and treated (effluent) wastewater and investigated using NGS technology. Samples of influent and effluent stream (from March, May of 2016 and February of 2017) were collected at the treatment station of wastewater in Brasília, Brazil. Samples were submitted to RNA extraction process and the cDNA libraries were sequenced using Illumina HiSeq 2000 with the condition of 100 base paired-end. The NGS reads were trimmed by Trimmomatic and the contigs were assembled with Megahit and Velvet. The assembled contigs were analyzed by tBLASTX and Megablast, respectively, against RefSeq Virus using Geneious Software v.8.1. Resulted reads were also uploaded and analyzed on Kaiju online platform. SaV were detected in the six sequenced samples, HAstV and NoV were found in all samples except the May untreated water sample. The results found were discussed and compared with Brazilian and international studies.
19

Tratabilidade do lodo de decantadores convencional e de alta taxa

Silva Junior, Archimedes Pereira da 26 February 2003 (has links)
Orientador: Ricardo de Lima Isaac / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Civil / Made available in DSpace on 2018-08-05T08:38:56Z (GMT). No. of bitstreams: 1 SilvaJunior_ArchimedesPereirada_M.pdf: 2766426 bytes, checksum: c4a329b55233959c0c769a4fd9c68911 (MD5) Previous issue date: 2003 / Resumo: Os principais resíduos de ETAs são os Iodos gerados nos decantadores, a água de lavagem dos filtros e o rejeito de limpeza dos tanques de produtos químicos. Os lodos mesmo classificados como resíduos sólidos, apresentam baixíssimo teor de sólidos. Sendo o custo do transporte e disposição final bastante elevado, a redução do volume constitui-se em alternativa, economicamente, viável. Os principais processos utilizados para redução de volume do Iodo são o adensamento, o condicionamento químico e a desaguamento. A pesquisa teve por objetivo comparar a tratabilidade do Iodo do decantador do tipo convencional e do decantador de alta taxa, da SANASA, na cidade de Campinas. Foi verificada a influência dos parâmetros que caracterizam a qualidade do Iodo, no seu desaguamento; o efeito do adensamento do Iodo por gravidade, com auxílio de polímeros e o efeito do condicionamento químico com polímeros no desaguamento, por centrifuga. O lodo bruto foi pré-condicionado com polímeros sintéticos, e também se investigou a eficiência destes no condicionamento do lodo já adensado, para sua centrifugação. O adensamento mostrou que o polímero aniônico foi o melhor para ambas as ETAs. A dosagem ótima foi a mesma para ambas as épocas, para as duas ETAs, sendo de 1mg/g para ETA-3 e 3g/Kg para ETA-4. O tempo de mistura, para ETA-3, foi maior na época seca (45s) do que no período de chuvas (30s). Para ETA-4 o tempo de mistura foi o mesmo (60s) para as duas épocas. O lodo adensado foi condicionado com polímero e submetido à centrifugação. Desta, concluiu-se que, para o período de chuvas e para os dois tipos de lodo a condição ótima foi: polímero catiônico, 1g/Kg, 5s de mistura e 200rpm de rotação. Na época de estiagem e lodo da ETA-3 a condição ótima foi dada por: polímero catiônico, 1g/Kg, 60s de mistura e 200rpm de rotação. No caso da ETA-4, a condição é dada por: polímero catiônico, 2,5g/Kg, 60 s de mistura e 100 rpm / Abstract: The main residues of WTPs are sludge from thickener, filter backwash waters and solids from basins of chemicals products. The sludge even labeled as solid residues present very low solids content. Like the costs of transportation and ultimate disposal are very high, to reduce the sludge volume is an economical feasible alternative. The principal methods used to reduce the sludge volume are thickening, chemical conditioning and dewatering. The aim of this research was to compare the handling of both sludge from the conventional and high-rate thickener. It was checked the influence of the parameters that give particular characteristics to the sludge in its dewatering; the gravity thickening with polymers aid and the influence of the polymers in the sludge dewatering with centrifuge. The raw sludge was conditioned with synthetics polymers. Also was checked whether that polymers were efficient in the thickened sludge conditioning aiming its centrifugation. The best polymer to the gravity thickening for both sludge (WTPs 3 and 4) was the anionic polymer. The same polymer dose was required for the both seasons studied (wet and dry) and for the two WTPs. It was 1mg/g to the WTP-3 and it was 3g/Kg to the WTP-4. The mixing time for the WTP-3 was greater in the dry season (45s) than the wet season (30s) and the mixing time was the same (60s) in both seasons for the WTP-4. The thickened sludge was conditioned with organic synthetic polymer and subjected to centrifugation. After this, was concluded that in the wet season and for the two kinds of sludge the optimum condition s given to: cationic polymer, 1g/Kg of polymer dose, mixing time of 5s and 200 rpm of centrifuge rotation. In the dry season and residues from WTP-3 the optimum condition is given to: cationic polymer, 1g/Kg of polymer dose, mixing time of 60s and 200 rpm of centrifuge rotation. For residues from WTP-4 the optimum condition is given to: cationic polymer, 2,5g/Kg of polymer dose, mixing time of 60s and 100 rpm of centrifuge rotation / Mestrado / Saneamento e Ambiente / Mestre em Engenharia Civil
20

Estudo de reuso e reciclagem de agua de lavagem de filtro rapido de estação de tratamento de agua, em sistema de ciclo fechado, independente / Study of reuse and recycling of rapid filter backwash water from water treatment plant in independent close cycle system

Reis, Jose Roberto Bezerra dos 09 November 2009 (has links)
Orientador: Ruben Bresaola Junior / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Civil, Arquitetura e Urbanismo / Made available in DSpace on 2018-08-14T17:21:03Z (GMT). No. of bitstreams: 1 Reis_JoseRobertoBezerrados_M.pdf: 4806731 bytes, checksum: f4634921271dbf74dd3233925df387a5 (MD5) Previous issue date: 2009 / Resumo: O projeto foi desenvolvido visando estudar o tratamento e o reuso da água de lavagem de filtro para reciclagem nesta função, dentro de um circuito fechado, em sistema independente das atividades de produção de uma estação de tratamento de água de abastecimento. O sistema foi dotado de unidade de mistura de polímero, pré-filtro de pedregulho e filtro de dupla camada (F3), semelhante aos usados na estação de tratamento de água. O pré-filtro foi retirado do sistema porque não forneceu a eficiência esperada. Com esta disposição foi monitorado o número de vezes que a água obtida poderia ser reutilizada sem influir na qualidade da água de início de filtração do filtro piloto F1, o que mostrou ser maior ou igual cinco vezes. A perda da água de lavagem no sistema foi de 0,13%, bastante significativo perante os valores costumeiros de 2 a 5%. O sistema operou sempre com partículas floculentas, nunca com partículas coloidais. / Abstract: The project was developed with the aim of studying the treatment and the reuse of rapid filter backwash water for recycling in this role, within a closed cycle, under system independent of production activities of a water treatment plant. The system was assembled with a polymer blending unit, a gravel preliminary upflow filter and a dual layer filter(F3), similar to those used in the water treatment plant. The pre-filter was withdrawn because it did not provided the expected efficiency. With this provision, it was monitored the number of times that water obtained could be reused without affecting the quality of water filtration top of the filter F1 which proved to be greater or equal to five times. The loss of filter backwash water in the system was 0,13%, quite significant when compared to the usual 2 to 5%. The system always worked with flocculent particles, not with colloidal particles. / Mestrado / Saneamento e Ambiente / Mestre em Engenharia Civil

Page generated in 0.1039 seconds