• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 77
  • 2
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • 1
  • Tagged with
  • 82
  • 82
  • 36
  • 32
  • 32
  • 32
  • 20
  • 19
  • 12
  • 12
  • 11
  • 10
  • 7
  • 7
  • 7
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
31

Uso urbano não potável de efluentes de estações de tratamento de esgoto sanitário : estudo de caso : município de Campo Largo - PR / Simone Soares Göhringer ; orientador, Miguel Mansur Aisse

Göhringer, Simone Soares January 2006 (has links)
Dissertação (mestrado) - Pontifícia Universidade Católica do Paraná, Curitiba, 2006 / Inclui bibliografia / O uso de efluentes de Estações de Tratamento de Esgoto em locais onde sejam admitidas águas de qualidade inferior, além de mitigar a poluição hídrica, surge como uma proposta de disponibilizar esta mesma quantidade ao abastecimento potável, proporcionando
32

Reuso de água em um sistema integrado com peixes, sedimentação, ostras e macroalgas / Water reuse in an integrated system with fishes, Sedimentation, oysters and macroalgae

Cavalcante Júnior, Valdemar January 2006 (has links)
CAVALCANTE JÚNIOR, Valdemar. Reuso de água em um sistema integrado com peixes, sedimentação, ostras e macroalgas. 2006. 56 f. : Dissertação (mestrado) - Universidade Federal do Ceará, Centro de Ciências Agrárias, Departamento de Engenharia de Pesca, Fortaleza-CE, 2006 / Submitted by Nádja Goes (nmoraissoares@gmail.com) on 2016-07-22T13:35:05Z No. of bitstreams: 1 2006_dis_vcavalcantejúnior.pdf: 798516 bytes, checksum: e6e72e0be76d7e9e806c45e94f8677e1 (MD5) / Approved for entry into archive by Nádja Goes (nmoraissoares@gmail.com) on 2016-07-22T13:35:22Z (GMT) No. of bitstreams: 1 2006_dis_vcavalcantejúnior.pdf: 798516 bytes, checksum: e6e72e0be76d7e9e806c45e94f8677e1 (MD5) / Made available in DSpace on 2016-07-22T13:35:22Z (GMT). No. of bitstreams: 1 2006_dis_vcavalcantejúnior.pdf: 798516 bytes, checksum: e6e72e0be76d7e9e806c45e94f8677e1 (MD5) Previous issue date: 2006 / Intensive culture effluents have high levels of dissolved nutrients mainly ammonia and others suspended solids. The objective of this work was to use integrated aquaculture with fishes, sedimentation, oysters and macroalgae to improve water quality from a salt water tilapia culture. The fishes water was distributed in three sedimentation aquariums to a 24 h period. Then, water was removed to three oysters aquariums to a equal 24 h period. Later, oysters water was removed to three macroalgae aquariums to more 24 h. Finally, macroalgae water returned to the fishes aquariums. Water turbidity and ammonia, nitrates, nitrites and phosphates concentrations were determined daily. The system was efficient to significantly reduce turbidity and ammonia and phosphates water levels. Nitrates and nitrites levels only were reduced during the sedimentation after system stabilization / Os efluentes de cultivo intensivo contêm elevadas concentrações de nutrientes dissolvidos, principalmente amônia, além de outros sólidos em suspensão. O objetivo desse trabalho foi utilizar a aqüicultura integrada com sedimentação, ostras e macroalgas para melhorar a qualidade da água proveniente de um cultivo de tilápias em água salgada. A água dos peixes foi distribuída em três aquários para sedimentação por 24 horas. Em seguida, a água foi transferida para três aquários com ostras, por igual período de 24 horas. Posteriormente, a água das ostras foi transferida para três aquários com macroalgas por mais 24 horas. Finalmente, a água das macroalgas retornou para os aquários com os peixes. Diariamente, foram avaliados a turbidez da água e as concentrações de amônia, nitratos, nitritos e fosfatos. O sistema foi eficiente em reduzir significativamente a turbidez e os níveis de amônia e fosfatos da água. Os níveis de nitratos e nitritos só foram reduzidos na sedimentação, após a estabilização do sistema. i
33

Avaliação do atual potencial de reúso de água no Estado do Ceará e propostas para um sistema de gestão / The current assessment of potential water reuse in the state of Ceará and proposals for a management system

Caixeta, Cláudia Elizângela Tolentino 25 January 2010 (has links)
CAIXETA, C. E. T. Avaliação do atual potencial de reúso de água no Estado do Ceará e propostas para um sistema de gestão. 2010. 324 f. Tese (Doutorado em Engenharia Civil: Saneamento Ambiental) – Centro de Tecnologia, Universidade Federal do Ceará, Fortaleza, 2010. / Submitted by João silva (jpauloqxb@gmail.com) on 2016-04-25T18:03:51Z No. of bitstreams: 1 2010_tese_cetcaixeta.pdf: 6903861 bytes, checksum: 2a9af853a33fcc0441f79d99565d008b (MD5) / Approved for entry into archive by Marlene Sousa (mmarlene@ufc.br) on 2016-04-29T17:14:37Z (GMT) No. of bitstreams: 1 2010_tese_cetcaixeta.pdf: 6903861 bytes, checksum: 2a9af853a33fcc0441f79d99565d008b (MD5) / Made available in DSpace on 2016-04-29T17:14:37Z (GMT). No. of bitstreams: 1 2010_tese_cetcaixeta.pdf: 6903861 bytes, checksum: 2a9af853a33fcc0441f79d99565d008b (MD5) Previous issue date: 2010-01-25 / The main objective of this work was evaluate the potential for water reuse in the state of Ceara as a contribution to the effective management of water resources and the conservation of the state. It consisted of the following stages: (1) literature, (2) A bibliographical survey; (2) description of the Ceara State (area under study); (3) definition of alternatives and criteria for reuse, (4) survey of treatment plants with respective flow rates and characteristics of treatment system for selection of those whose effluent can be used, (5) proposition (s) type (s) to reuse the selected treatment plants, (6) economic feasibility study for the financial reuse industrial (7) conditions of proposition and guidelines for the strengthening of reuse in the State, (8) present and discuss the results and (9) assessing the work undertaken. As results of the study we can mention: (1) The industrial reuse was feasible to be deployed in DI Maracanaú, and the effluent standard type 2 (effluent from the stabilization pond, mixing tank for pH correction, flocculant, decantor, carbonation tank and final effluent) showed the best economic and financial viability. (2) Research conducted with companies in the DI Maracanaú showed great responsiveness on the part of potential users, since it is guaranteed quality, quantity and price competitive with current power supply. (3) Of the 12 systems evaluated the Tupamirim WTPT presented the best conditions for the practice of non-potable urban reuse - irrigation of green areas in Fortaleza (4) The system of stabilization ponds in operation in the RMF and the State can provide a flow of about 1872.0 L / s, and these volumes will benefit approximately 3279.66 hectares, whereas the demand for irrigation equal to18,000 m3/ha.ano, or supply, on average, a growing area of 1,497,600 m2 fish (149.7 ha). The main conclusions of this work are: (1) The implementation of water reuse in Ceará is an important alternative to be considered in the State Plan for Water Resources, as it may: contribute effectively in the conservation of water resources, increase the supply of water for agricultural, fish and industry in the state, through the provision of reclaimed water for uses that can dispense the drinking, and provide a greater volume of water of good quality to end uses, as recommended by Agenda 21.(2) Among the types of reuse study for the state, all proved viable. As the industrial reuse which will require a larger investment. Since the re-use agricultural and fish are the easiest to implement, requiring only a determination of the State Government so that it signed a partnership betweean Cagece and SDA thus enable the implementation of projects.(3) The reuse of wastewater in the state of Ceara is a viable alternative, but necessary regulations to mitigate the pest risk that may arise from the practice without the adoption of multiple barriers to ensure protection of population health. Is no denying the need to establish guidelines that allow the practice of reuse to become secure, ubiquitous, thus helping to minimize the problem of water scarcity in the state. / Este trabalho teve como objetivo avaliar o potencial de reúso de águas no Estado do Ceará como forma de contribuir para o efetivo gerenciamento dos recursos hídricos e para a conservação ambiental do Estado. O trabalho foi desenvolvido observando as seguintes etapas: (1) levantamento bibliográfico; (2) caracterização do Estado do Ceará (área de estudo); (3) definição das alternativas e critérios de reúso; (4) levantamento das ETEs com respectivas vazões e as características do sistema de tratamento para seleção daquelas cujos efluentes podem ser utilizados; (5) proposição do(s) tipo(s) de reúso para as ETEs selecionadas; (6) estudo de viabilidade econômica financeira para o reúso industrial; (7) proposição de condições e diretrizes para o fortalecimento do reúso no Estado; (8) apresentar e discutir os resultados; (9) avaliar o trabalho desenvolvido. O trabalho tem como resultados: (1) O reúso industrial mostrou-se viável para ser implantado no Distrito Industrial (DI) de Maracanaú, sendo que o efluente do tipo Padrão 2 (efluente da lagoa de estabilização, tanque de mistura para correção do pH, floculador, decantor tanque de recarbonatação e efluente final) foi o que apresentou melhor viabilidade econômico financeira. (2) Pesquisa realizada junto às empresas do DI de Maracanáu evidenciou grande receptividade por parte dos usuários potenciais, desde que sejam garantidos qualidade, quantidade e preço competitivo com a atual fonte de abastecimento.(3) Dos 12 sistemas avaliados, a ETE Tupamrim foi a que apresentou condições mais adequadas para a prática do reúso urbano não potável – rega de áreas verdes de Fortaleza. (4) Os sistemas de lagoas de estabilização em operação na RMF e interior do Estado podem disponibilizar uma vazão de cerca de 1.872,0 L/s, e tais volumes poderão beneficiar cerca de 3.279,66 hectares, considerando uma demanda para irrigação igual a 18.000 m3/ha.ano; ou suprir, em média, uma área de cultivo de peixes de 1.497.600 m2 (149,7 ha). Com base nos resultados pode-se concluir: (1) A implementação de reúso de água no Ceará é uma alternativa importante a ser considerada no Plano Estadual de Recursos Hídricos, pois poderá: contribuir efetivamente na preservação dos recursos hídricos; aumentar a oferta de água para os setores agrícola, piscícola e industrial no Estado, por meio da disponibilização da água recuperada aos usos que possam prescindir de potabilidade; e disponibilizar um volume maior de água de boa qualidade aos usos nobres, conforme preconiza a Agenda 21. (2) Dentre as modalidades de reúso estudadas para o Estado, todas se mostraram viáveis, sendo o reúso industrial o que vai necessitar de um maior investimento. Já os reúso agrícola e em piscicultura são os mais fáceis de serem implementados, necessitando apenas de uma determinação do Governo do Estado para que seja firmada uma parceria entre Cagece e SDA e, dessa forma, viabilizar a implantação dos projetos. (3) O reúso de águas residuárias no Estado do Ceará é uma alternativa viável, desde que haja uma regulamentação para minimizar os riscos epidemiológicos que podem advir da prática sem a adoção de barreiras múltiplas para garantir a proteção da saúde populacional. É incontestável a necessidade do estabelecimento de diretrizes que permitam que a prática do reúso se torne segura e difundida, contribuindo assim para a minimização do problema de escassez de água no Estado.
34

Avaliação dos aspectos sanitários, agronomicos e de qualidade em melancias irrigadas com esgoto tratado / Avaliation of the sanitary, agronomics and final product quality aspects in watermelons irrigated with treated sewage

Costa, Mayara Carantino 28 July 2006 (has links)
COSTA, M. C. Avaliação dos aspectos sanitários, agronomicos e de qualidade em melancias irrigadas com esgoto tratado. 2006. 112 f. Dissertação (Mestrado em Engenharia Civil: Saneamento Ambiental) – Centro de Tecnologia, Universidade Federal do Ceará, Fortaleza, 2006. / Submitted by Hohana Sanders (hohanasanders@hotmail.com) on 2016-04-28T14:36:40Z No. of bitstreams: 1 2006_dis_mccosta.pdf: 6642585 bytes, checksum: 9160f6c72e1b7947abe8ff24ba59719a (MD5) / Approved for entry into archive by Marlene Sousa (mmarlene@ufc.br) on 2016-06-02T17:05:23Z (GMT) No. of bitstreams: 1 2006_dis_mccosta.pdf: 6642585 bytes, checksum: 9160f6c72e1b7947abe8ff24ba59719a (MD5) / Made available in DSpace on 2016-06-02T17:05:23Z (GMT). No. of bitstreams: 1 2006_dis_mccosta.pdf: 6642585 bytes, checksum: 9160f6c72e1b7947abe8ff24ba59719a (MD5) Previous issue date: 2006-07-28 / The reuse of treated sewage on watermelon irrigation, variety Crimson Sweet, was investigated not only considering the sanitary aspects but also the productivity and final product quality. The experiment was conducted in the Research Centre on Wastewater Treatment and Reuse, owned by the Company of Water and Wastewater of Ceará, in Aquiraz-CE. The experimental delimitation was randomized blocks, with four repetitions and four treatments: raw water and soil fertilization (T1); treated wastewater and soil fertilization (T2); treated wastewater without external soil fertilization (T3); and treated wastewater and half of soil fertilization (T4). The irrigation waters used (raw water and effluent of a stabilization pond) were characterized by the physical-chemical and microbiological aspects. Both waters were in the limits normalized by the World Health Organization (WHO) for unrestricted irrigation. The irrigation methods drip and furrow were compared in verifying of which one is more suitable for effluent reuse on watermelon production. The productivity data indicated that there was no significative difference among the treatments on drip irrigation, where the biggest productivities were obtained on T1 and T2 treatments. For the furrow system, no satisfactory productivity was achieved. The study revealed a significative difference among the treatments regarding the physical-chemical characteristics of the fruits. However, the microbiological quality was never compromised. Sensorial tests revealed that only the treatment T2 (treated wastewater and soil fertilization) did not present a different flavour, significative on 5% level, compared to the treatment T1 (control), and that the irrigation systems drip and furrow could be indifferently used without compromising the product flavour. / Investigou-se o reúso de esgoto sanitário tratado na irrigação da cultura da melancia, variedade Crimson Sweet, tanto relacionado aos aspectos sanitários como também à produtividade e à qualidade do produto final. O estudo foi realizado no Centro de Pesquisa sobre Tratamento de Esgoto e Reúso de Águas da Companhia de Água e Esgoto do Ceará em Aquiraz-CE. O delineamento experimental foi em blocos ao acaso, com quatro repetições e quatro tratamentos: T1 - água do poço mais adubação; T2 - efluente mais adubação; T3 - efluente e T4 - efluente mais a metade da adubação. As águas de irrigação utilizadas (água de poço e efluente de lagoas de estabilização) foram caracterizadas sob os aspectos físico-químicos e microbiológicos, em que ambas estavam dentro dos limites estabelecidos pela OMS para irrigação irrestrita. Os métodos de irrigação por gotejamento e sulco foram comparados para a verificação do mais indicado para o reúso com efluentes na cultura da melancia. Por meio de análise dos dados de produtividade da cultura observou-se que não houve diferença significativa entre os tratamentos na irrigação por gotejamento, sendo que os melhores resultados foram obtidos nos tratamentos T1 e T2. Para o sistema de sulco, não foram obtidas produtividades satisfatórias. . O estudo indicou que houve diferença significativa entre os tratamentos em relação às características físico-químicas dos frutos produzidos, contudo, não houve comprometimento da qualidade microbiológica dos mesmos em nenhum dos tratamentos avaliados. Em relação às características sensoriais observou-se, que somente as amostras que receberam o tratamento T2 (irrigação com efluente mais adubação) não apresentaram sabor diferente, significativo ao nível de 5%, quando comparadas àquelas submetidas ao tratamento controle (T1), e que os sistemas de irrigação, sulco e gotejo, podem ser utilizados, indiferentemente, sem comprometer o sabor dos frutos produzidos
35

Desempenho de um “wetland” vertical aplicado ao tratamento do efluente de um filtro anaeróbio em uma estação de tratamento de águas cinzas claras visando o reúso não potável em edificações residenciais

Sarnaglia, Solange Aparecida Alho 29 April 2014 (has links)
Submitted by Elizabete Silva (elizabete.silva@ufes.br) on 2015-11-24T17:51:52Z No. of bitstreams: 2 license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) DESEMPENHO DE UM “WETLAND” VERTICAL APLICADO AO TRATAMENTO DO EFLUENTE DE UM FILTRO ANAERÓBIO EM UMA ESTAÇÃO DE TRATAMENTO DE ÁGUAS CINZAS CLARAS VISA.pdf: 3255529 bytes, checksum: 8022681ce88c7c07637bc323ca8d3384 (MD5) / Approved for entry into archive by Morgana Andrade (morgana.andrade@ufes.br) on 2016-01-05T12:08:27Z (GMT) No. of bitstreams: 2 license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) DESEMPENHO DE UM “WETLAND” VERTICAL APLICADO AO TRATAMENTO DO EFLUENTE DE UM FILTRO ANAERÓBIO EM UMA ESTAÇÃO DE TRATAMENTO DE ÁGUAS CINZAS CLARAS VISA.pdf: 3255529 bytes, checksum: 8022681ce88c7c07637bc323ca8d3384 (MD5) / Made available in DSpace on 2016-01-05T12:08:27Z (GMT). No. of bitstreams: 2 license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) DESEMPENHO DE UM “WETLAND” VERTICAL APLICADO AO TRATAMENTO DO EFLUENTE DE UM FILTRO ANAERÓBIO EM UMA ESTAÇÃO DE TRATAMENTO DE ÁGUAS CINZAS CLARAS VISA.pdf: 3255529 bytes, checksum: 8022681ce88c7c07637bc323ca8d3384 (MD5) Previous issue date: 2014 / FINEP, CNPq / No tratamento de água cinza com vistas ao reúso predial os “wetlands” têm se mostrado como uma opção viável devido à boa remoção de poluentes, ao baixo custo de implantação e operação, além do baixo impacto ambiental quando comparados a outros sistemas. O presente estudo teve como objetivo caracterizar físico-química e microbiologicamente a água cinza clara gerada em um edifício universitário avaliar a influência das cargas hidráulica e orgânica na remoção de matéria orgânica, turbidez e de coliformes termotolerantes num “wetland” vertical (WV); e, por fim, avaliar a produtividade e verificar os teores de macro e micronutrientes 333presentes na biomassa vegetal das macrófitas utilizadas no WV utilizado como pós-tratamento de um filtro anaeróbio tratando água cinza clara. Foram avaliados seis períodos de testes no WV, sendo estes caracterizados pelos tempos de detenção hidráulica (TDH) de 3; 2; 1; 0,75 e 0,5 dia. Os valores médios de turbidez dos efluentes referentes aos TDH estudados foram de 15 UT, 10,3 UT, 5,3 UT, 7,0UT e 4,8 UT respectivamente. As concentrações médias de SST foram de 7,2 mg.L-1, 7,1 mg.L-1, 7,0 mg.L-1,8,0 mg.L-1 e 14,5 mg.L-1, respectivamente. Já as concentrações médias de DQO foram de 12 mgO2.L-1, 27 mgO2.L-1, 14 mgO2.L-1, 27 mgO2.L-1 e 25 mgO2.L-1,e de DBO5 foram de 17 mgO2.L-1, 22 mgO2.L-1, 14 mgO2.L-1, 23 mgO2.L-1 e 11 mgO2.L-1,respectivamente.A densidade média de CT obtida no efluente do WV foi de 2,7x104 NMP.100mL-1 e de E. coli foi de 6,9x10² NMP.100mL-1. Por fim, a análise foliar da macrófita utilizada neste estudo teve como resultado, uma produtividade média de 0,3 kg de matéria seca/m2, com uma estimativa de produtividade da parte aérea de 1,9 kg.m-2. As absorções médias de macronutrientes foram: 111 mg.m-2 de N; 2,0 mg.m-2 de P; 21,4 mg.m-2 de K; 8,0 mg.m-2 de Ca; 1,1 mg.m-2 de Mg; 1,8 mg.m-2 de S; Por fim, para os micronutrientes as remoções encontradas foram: 9,9 mg.m-2 de Cu; 34,7 mg.m-2 de Mn; 144,6 mg.m-2 de Fe; 112,1 mg.m-2 de Zn e 17,1 mg.m-2 de B. Concluiu-se que o WV apresentou melhor desempenho para o TDH de 3 dias ao longo dos períodos analisados, mostrando-se viável quando utilizado como pós-tratamento de um filtro anaeróbio. / The wetlands have been shown as a viable option for the greywater treatment aiming the building reuse due to the good pollutants removal, the low cost of implantation and operation, as well as minimal environmental impact when compared with another systems. The present study aimed to characterize the physico-chemical and microbiologically the light greywater generated in university building; evaluate the influence of hydraulic and organic loads in removing turbidity and organic matter in a vertical "wetland" used as a post-treatment of an upflow anaerobic filter (AF) treating greywater clear; evaluate the influence of hydraulic and organic loads in the inactivation of thermotolerant coliform in a vertical "wetland" used as post-treatment of an anaerobic filter treating greywater clear, and evaluate the performance and verify the contents of macro and micronutrients present in the biomass of macrophytes used in "wetland" vertical. Were analyzed six periods of experiments, being characterized by the hydraulic retention time (HRT) of 0.25; 0.5; 0.75; 1; 2 e 3 days. The average values of the effluents related to the turbidity the (HRT) studied were 5.2, 4.8 UT, UT 7.0, 5.3 UT 10.3 UT and UT 15, respectively. The average concentrations of TSS were 6.0 mg L-1, 14.5 mg L-1, 8.0 mg L-1, 7.0 mg L-1, 7.1 mg L-1 and 7.2 mg L-1, respectively. As for the average COD concentrations were 14 mgO2.L-1, 25 mgO2.L-1, 27 mgO2.L-1, 14 mgO2.L-1, 27 mgO2.L-1and 12 mgO2.L-1 and BOD5 were 6 mgO2.L-1, 11mgO2.L-1, 23 mgO2.L-1, 14mgO2.L-1, 22 mgO2.L-1 and 17 mgO2.L-1, respectively.The mean density obtained of TC in the VW effluent was 2.7x104 NMP.100mL-1 and the E. coli was6.9x10² NMP.100mL-1. Finally, the analysis the leaf of macrophyte used in this study resulted in a productivity the 0.298 kg material dry/m2, with an estimated yield of shoots of 1.9 kg.m-2. The absorption of macronutrients were: 111 mg.m-2 N; 2.0 mg.m-2 P; 21.4 mg.m-2 K; 8.0 mg.m-2 Ca; 1, 1 mg.m-2 Mg and 1.8 mg.m-2 S. Finally, for micronutrients removals were: 9.9 mg.m-2 Cu; 34.7 mg.m-2 Mn; 144.6 mg.m-2 Fe; 112.1 mg.m-2 Zn and 17.1 mg.m-2 B.It was concluded that the VW showed better performance for the HRT of 3 days over the analyzed periods, making it adequate when used such as post-treatment of an anaerobic filter.
36

Determinação de metais em águas de abastecimento público : um estudo de caso, município de Ouro Preto.

Ramos, Alisson Martins January 2016 (has links)
Programa de Pós-Graduação em Sustentabilidade Socioeconômica e Ambiental. Núcleo de Pesquisas e Pós-Graduação em Recursos Hídricos, Pró-Reitoria de Pesquisa e Pós Graduação, Universidade Federal de Ouro Preto. / Submitted by giuliana silveira (giulianagphoto@gmail.com) on 2016-05-12T17:12:59Z No. of bitstreams: 1 DISSERTAÇÃO_DeterminaçãoMetaisÁguas.pdf: 4297879 bytes, checksum: 9a2732c1128f3feecd4eb28faa179756 (MD5) / Approved for entry into archive by Gracilene Carvalho (gracilene@sisbin.ufop.br) on 2016-05-13T18:25:04Z (GMT) No. of bitstreams: 1 DISSERTAÇÃO_DeterminaçãoMetaisÁguas.pdf: 4297879 bytes, checksum: 9a2732c1128f3feecd4eb28faa179756 (MD5) / Made available in DSpace on 2016-05-13T18:25:04Z (GMT). No. of bitstreams: 1 DISSERTAÇÃO_DeterminaçãoMetaisÁguas.pdf: 4297879 bytes, checksum: 9a2732c1128f3feecd4eb28faa179756 (MD5) Previous issue date: 2016 / Ao longo das últimas quatro décadas, a preocupação com a qualidade da água para consumo humano vem ganhando destaque no Brasil. Neste período foram criados e aperfeiçoados marcos legais pertinentes ao tema, com o objetivo de reduzir os riscos à saúde humana ao atribuir diferentes responsabilidades aos atores sociais envolvidos. O município de Ouro Preto – MG está inserido no Quadrilátero Ferrífero, que em razão de suas características geológicas possibilitam a ocorrência de determinados metais e outros elementos químicos perigosos à saúde em seus mananciais hídricos. Além disto, atividades antrópicas, como a mineração, agricultura e atividades domésticas e industriais podem alterar as características da água. O serviço de abastecimento de água do município conta com estruturas de tratamento convencional e simplificado, em diferentes localidades. Diante da possibilidade de ocorrência destes elementos nas águas destinadas ao abastecimento público do município acima do valor máximo permitido pela legislação brasileira, este trabalho buscou realizar sua identificação e quantificação de elementos por meio da utilização da técnica de Fluorescência de Raios – X por Reflexão Total (TXRF). Além disto, o trabalho busca discutir a eficiência das estruturas de tratamento de água em remover estes elementos de forma a atender os parâmetros de potabilidade vigentes. As análises de água tratada de sistemas com tratamento simplificado apresentaram resultados insatisfatórios para os elementos ferro e manganês, nas localidades de Santa Rita de Ouro Preto e Mota, enquanto todas as análises de água tratada oriundas de tratamento convencional apresentaram resultado dentro dos parâmetros. _____________________________________________________________________________ / ABSTRACT : Over the past four decades, the concern with the quality of drinking water has been gaining attention in Brazil. In this period have been created and improved legal frameworks relevant to the theme, in order to reduce risks to human health besides contributing to assign different responsibilities to social actors involved. The city of Ouro Preto - MG is inserted in the Iron Quadrangle, which due to its geological characteristics allow the occurrence of certain metals and other hazardous chemicals in their water sources. In addition, human activities such as mining, agriculture and domestic and industrial activities can change the characteristics of the water. The water services of the municipality account with structures of conventional and simplified water treatments, in different localities. Faced with the possibility of occurrence of hazardous chemicals in water intended for municipal public supply above the maximum permitted limits, established by the Brazilian law, this study attempts to make the identification and quantification of metals by using the technique of total reflection X-ray fluorescence (TXRF). In addition, the work discusses the efficiency of water treatment facilities to remove these elements to meet the current potability parameters. The treated water analysis systems with simplified treatment showed unsatisfactory results for the removal of iron and manganese elements in the localities of Santa Rita de Ouro Preto and Mota, while all water analyzes treated originated from conventional treatment showed results within the law limits.
37

Pós tratamento de lixiviado de aterro industrial pelo processo de osmose reversa : estudo de caso

Chamon, Roberta Petry January 2011 (has links)
Orientador : Prof. Dr. Urivald Pawlowsky / Dissertação (mestrado) - Universidade Federal do Paraná, Setor de Tecnologia, Programa de Pós-Graduação em Engenharia de Recursos Hídricos e Ambiental. Defesa: Curitiba, 02/03/2011 / Bibliografia: fls. 212-218 / Resumo: Uma das grandes dificuldades no tratamento de lixiviado de aterro industrial consiste na remoção dos compostos orgânicos não biodegradáveis, representados, pelos altos valores de Demanda Química de Oxigênio (DQO). Este estudo foi realizado em um Centro de Tratamento o qual recebe, conforme NBR 10004, resíduos industriais de Classe I e Classe II. A tecnologia de Osmose Reversa (OR) foi empregada em três diferentes águas de alimentação obtidas no processo de tratamento do lixiviado gerado pela empresa. O objetivo principal consiste na verificação da sua qualidade final, principalmente quanto a remoção de compostos não biodegradáveis, e posterior reutilização desta água. Os seguintes efluentes foram testados: Efluente Tratado por Reator Biológico de Membrana (MBR), com valores médio de DQO de 197,3 ± 58,7mg/L, Efluente Tratado por processo de Lodos Ativados existente na empresa, com valor de DQO em torno de 1000 mg/L e, por fim, Efluente Retratado por processo Físico-Químico com adição de carvão tivado em pó, cujo valor de DQO é em torno de 700mg/L. Neste estudo foram utilizadas membranas de OR de poliamida, e a unidade piloto é formada por dois estágios de membrana de módulos espirais. O efluente após tratamento por MBR apresentou remoção de DQO em torno de 87,96%. Dentre os parâmetros analisados, as concentrações de Sólidos Totais Dissolvidos (STD) e do Carbono Orgânico Total (COT) nesta água foram em torno de 2670 mg/L e 27,43 mg/L e a remoção destes compostos atingiu valores na média de 94,65% e 96,07%. 4O MBR, portanto, apresentou-se como um prétratamento adequado ao sistema de OR, com tempo total de filtração de 15 horas. Além disso, água obtida é possível de ser reutilizada para fins não potáveis. Embora as remoções com os outros dois efluentes também tenham sido elevadas, a rápida queda na vazão de permeado e o alto potencial de colmatação das membranas que ambos apresentaram demonstram que a filtração destes efluentes pela tecnologia de OR é inviável sem a adoção de pré-tratamento anterior ao sistema. / Abstract: One of the most problems found in industrial landfill leachate treatments is remove the organic matters which are difficult to oxide biologically. This study was realized in Center of Treatment which receive, in agreement with NBR 10004, industrial waste classified as Class I and Class II. Those are represent mostly due high levels of Chemical Oxygen Demand (COD). Therefore, in this study three different feed waters from a leachate treatment plant were submitted to Reverse Osmosis (RO). The main purpose was verify the final quality from the permeates obtained, especially the value of COD and the possibility to reuse those waters. The feed waters where: treated effluent by membrane bioreactor (MBR) with ultrafiltration membranes, which present 197,3 ± 58,7mg/L of COD, treated effluent by activated sludge process from the wastewater plant that they have installed, which presents values of COD around 1000 mg/L; and finally retreated effluent by physicochemical process with addition of powdered activated carbon, with COD around 700mg/L. For this study spiral wound polyamide Reverse Osmosis membranes were used. The removal of COD from the treated effluent by MBR was around 87,95%. Some other parameters like Total Dissolved Solids (TDS) and Total Carbon Organic (COT) present values around 2670 mg/L and 27,43 mg/L respectively, with average removal around 94,65% and 96,07%. The color was 100% removed from all the feed waters. The MBR therefore, showed to be a good solution as pre-treatment for OR, with 15 hours of total time of filtration without chemical wash. Beside that the treated water obtained can be reused for non potable use. The removal of the compounds obtained for the others two effluents was good, with efficiencies around 90 – 99% but, the fast decrease of flowrate and the high potential to fouling and scaling of both demonstrated that these have no viability to be treated by OR. A pretreatment must be adopted before feed the system with them.
38

Análise de alternativas para conservação de água em edificações residenciais funcionais em Brasília-DF / Analysis of alternatives for water conservation in residential buildings of public employees in Brasília-DF

Vianna, Jorge Thiago Duarte da Silva 19 May 2017 (has links)
Dissertação (mestrado)—Universidade de Brasília, Faculdade de Tecnologia, Departamento de Engenharia Civil e Ambiental, 2017. / Submitted by Raquel Almeida (raquel.df13@gmail.com) on 2017-08-01T16:08:41Z No. of bitstreams: 1 2017_JorgeThiagoDuartedaSilvaVianna.pdf: 4414594 bytes, checksum: 3c21eb7fe7eded4fdfe4e244de46443c (MD5) / Approved for entry into archive by Raquel Viana (raquelviana@bce.unb.br) on 2017-08-31T21:14:34Z (GMT) No. of bitstreams: 1 2017_JorgeThiagoDuartedaSilvaVianna.pdf: 4414594 bytes, checksum: 3c21eb7fe7eded4fdfe4e244de46443c (MD5) / Made available in DSpace on 2017-08-31T21:14:34Z (GMT). No. of bitstreams: 1 2017_JorgeThiagoDuartedaSilvaVianna.pdf: 4414594 bytes, checksum: 3c21eb7fe7eded4fdfe4e244de46443c (MD5) Previous issue date: 2017-08-31 / O crescimento populacional, o uso indiscriminado da água e as mudanças climáticas vêm produzindo crises de abastecimento urbano de água. Nesse contexto se encontra Brasília, uma área altamente urbanizada, com predominância de nascentes, longos períodos de seca e risco de desabastecimento. Outro aspecto de Brasília é possuir o maior porcentual de imóveis funcionais do Brasil. Diante disso, este trabalho analisou os métodos de conservação de água em edificações residenciais funcionais no Plano Piloto, em Brasília. Para tanto, foram elencados dois estudos de caso, um imóvel a ser reformado (Categoria 1) e um imóvel a ser construído (Categoria 2). Para a análise, determinou-se o padrão de consumo e foram obtidos os consumos de água dos aparelhos, e concebido o emprego das tecnologias de conservação de água. A partir disso foram feitas as combinações das alternativas possíveis. Devido ao grande número de alternativas, foi realizada a triagem para se obter um conjunto menor de alternativas viáveis. Por meio de consulta a um painel de especialistas, foram estabelecidos objetivos e critérios de análise, e seus respectivos pesos. As alternativas selecionadas tiveram suas performances em cada critério calculadas, formando a matriz de consequências (“payoff”). Foram aplicados os métodos multicritério e multiobjetivo TOPSIS e ELECTRE III, para hierarquizar essas alternativas. Após a execução desses métodos, as duas categorias de edificação tiveram como alternativa classificada em primeiro lugar o uso de equipamentos economizadores de água. Na sequência, o aproveitamento de água de chuva destacou-se devido à melhor qualidade da água bruta e poucas interferências necessárias no imóvel, e vieram classificadas mais abaixo as alternativas envolvendo reúso com águas cinzas. Em geral, alternativas com alta concentração de coliformes fecais na água bruta tiveram sua classificação prejudicada. Como conclusão geral, esta pesquisa mostrou que não há em Brasília, até o momento, incentivo para medidas de conservação de água. Tal fato pôde ser comprovado pela posição de destaque da alternativa que refletia a não tomada de ações em ambas as categorias de edifícios. Por outro lado, demonstrou-se a viabilidade de algumas alternativas de conservação de água atendendo diversos objetivos e exigências distintas, tal qual o uso de dispositivos economizadores. / Population growth, the indiscriminate use of water and climate change have been leading to water supply crises. Brasilia is found in this context, a highly urbanized area, with a predominance of springs, long periods of drought and risk of shortages. Another aspect of Brasilia is to have the largest percentage of residences for civil servants in Brazil. Therefore, this work analyzed the methods of water conservation in this kind of residential buildings in the Pilot Plan, in Brasilia. To do so, two case studies were considered, a property to be renovated (Category 1) and a property to be built (Category 2). For the analysis, the consumption pattern was determined and the water consumption of the appliances was obtained, and the use of water conservation technologies was conceived. From this, the combinations of possible alternatives were made. Due to the large number of alternatives, screening was done to obtain a smaller set of viable alternatives. Through consultation to a panel of experts, objectives and criteria of analysis, and their respective weights, were established. The selected alternatives had their performances calculated in each criterion, forming the consequence matrix (“payoff matrix”). The multicriteria and multi-objective TOPSIS and ELECTRE III methods were applied to hierarchize these alternatives. After the execution of these methods, the two categories of buildings had as the first classified alternative the use of water saving equipment. Subsequently, the use of rainwater stood out due to the better quality of the raw water and few necessary interferences in the property, and the alternatives involving reuse with gray water were classified in position just below. In general, alternatives with high concentration of fecal coliforms in the raw water had their classification impaired. As a general conclusion, this research showed that there is no incentive for water conservation measures in Brasilia. This fact could be proven by the prominent position of the alternative that reflected the non-taking of actions in both categories of buildings. On the other hand, the viability of some water conservation alternatives has been demonstrated, meeting different objectives and requirements, such as the use of economising devices.
39

Cultivo hidropônico de alface com água de reúso

Cuba, Renata da Silva 06 February 2015 (has links)
Made available in DSpace on 2016-06-02T18:55:29Z (GMT). No. of bitstreams: 1 6677.pdf: 2112250 bytes, checksum: 23a60ac90f07a90b3b304868be4c948b (MD5) Previous issue date: 2015-02-06 / The water for many years was considered inexhaustible, and only in recent decades, became aware of the shortage and the need to rationalize their use, look for ways to reuse and recovery of its quality. In this search context for reuse alternatives, the use of treated sewage sludge in agriculture can become an important tool in water management. Therefore this study evaluated the production of lettuce (Lactuca sativa L.) using hydroponic reuse water from sewage treatment plant. The experiment was conducted at Agricultural Science Center - UFSCar, in Araras, SP, in the greenhouse. Crops occurred from February to March (summer) and July-August (winter) 2014. The hydroponic system adopted was the Nutrient Film Technique (NFT), three treatments, with the first supply of water and fertilizers (TA ), the second with sewage treated and supplemented with fertilizers according to results of previous chemical analysis (TRA), and the third only treated sewage (TR), distributed in four randomized blocks. Each treatment consisted of four plots (stands), a 500 L tank for storing the nutrient solution, a motor pump assembly and a timer. Four polypropylene hydroponic profiles with 3 meters long were used in each bench, with 48 plants per plot, totaling 192 plants per treatment. We evaluated the fresh weight, nutritional status and the microbiological quality culture, and the amount of fertilizer used in the treatments. The fresh weights were subjected to analysis of variance and means compared by Tukey test at 5% probability. Only the TR treatment showed a significant difference compared to the other, in which the plants showed symptoms of deficiency and have significant reduction in fresh weight (p <0.01). There was no detectable presence of E.coli in any treatment, and it was possible to obtain a saving of fertilizers in some of TRA compared to TR. These results suggest the feasibility of reusing water application as a water source for hydroponics, with the necessary corrections, and that the hydroponic profile can act as a barrier to prevent contact of the effluent with the lettuce leaves, according to the conditions and care adopted in handling. / A água durante muitos anos foi considerada inesgotável, e, somente nas últimas décadas, tomou-se consciência da situação de escassez e da necessidade de racionalizar seu uso, procurar formas de reúso e recuperação da sua qualidade. Neste contexto de busca por alternativas de reúso, o uso de efluentes de esgotos tratados na agricultura pode se tornar importante ferramenta no gerenciamento da água. Portanto este trabalho avaliou a produção de alface (Lactuca sativa, L.) hidropônica usando água de reúso proveniente de estação de tratamento de esgoto. O experimento foi realizado no Centro de Ciências Agrárias - UFSCar, no município de Araras, SP, em casa de vegetação. Os cultivos ocorreram de fevereiro a março (verão) e de julho a agosto (inverno) de 2014. O sistema hidropônico adotado foi a Técnica do Fluxo de Nutrientes (NFT), sendo três tratamentos, o primeiro com água de abastecimento e fertilizantes (TA), o segundo com água de esgoto tratada e complementada com fertilizantes de acordo com resultados de análise química prévia (TRA), e o terceiro somente água de esgoto tratada (TR), distribuídos em quatro blocos ao acaso. Cada tratamento foi composto por quatro parcelas (bancadas), um reservatório de 500 L para armazenar a solução nutritiva, um conjunto moto bomba e um temporizador. Foram utilizados quatro perfis hidropônicos de polipropileno com 3 metros de comprimento em cada bancada, com 48 plantas por parcela, totalizando 192 plantas por tratamento. Avaliou-se a massa fresca, o estado nutricional e a qualidade microbiológica cultura, e a quantidade de fertilizantes usados nos tratamentos. Os valores de massa fresca foram submetidos à análise de variância e as médias comparadas pelo teste de Tukey a 5% de probabilidade. Apenas o tratamento TR apresentou diferença significativa em relação aos demais, no qual as plantas apresentaram sintomas de deficiência e tiverem redução na massa fresca significativa (p<0,01). Não foi detectado presença de E. coli em nenhum dos tratamentos, e foi possível obter uma economia de alguns de fertilizantes no TRA em comparação ao TA. Esses resultados sugerem a viabilidade da aplicação de água de reúso como fonte de água para a hidroponia, com as correções necessárias, e que o perfil hidropônico pode atuar como uma barreira para impedir o contato do efluente com as folhas de alface, de acordo com as condições e cuidados adotados na manipulação.
40

Avaliação técnica e econômica da utilização do efluente da ETE Martinópolis - São José dos Pinhais - PR

Pompeo, Raquel Pinheiro January 2007 (has links)
Orientador : Marcelo Antunes Nolasco / Dissertação (mestrado) - Universidade Federal do Paraná, Setor de Tecnologia, Programa de Pós-Graduação em Engenharia de Recursos Hídricos e Ambiental. Defesa: Curitiba, 13 de junho de 2007 / Inclui bibliografia / Área de concentração: Engenharia Ambiental

Page generated in 0.4559 seconds