• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 619
  • 7
  • 6
  • 6
  • 6
  • 6
  • 4
  • 2
  • Tagged with
  • 643
  • 643
  • 342
  • 221
  • 167
  • 144
  • 127
  • 107
  • 92
  • 84
  • 80
  • 77
  • 76
  • 67
  • 66
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
421

Correlação entre fator de toxicidade e parâmetros físico-químicos para efluentes domésticos tratados

Amaral, Karina Guedes Cubas do 16 July 2012 (has links)
No Brasil diversas estações adicionam policloreto de alumínio no lodo biológico para melhorar a eficiência da coagulação/ floculação e clarificação e adicionam hipoclorito de sódio no efluente tratado para a desinfecção. Usualmente o monitoramento das Estações é realizado em muitos casos apenas através da determinação de parâmetros físico-quimicos. Neste estudo foram realizadas análises em amostras obtidas em diferentes condições operacionais de uma ETE sanitária de uma indústria localizada na região metropolitana de Curitiba. As amostras foram coletadas a fim de realizar avaliações dos parâmetros físico-químicos e de toxicidade. As amostras apresentaram resultados dentro do limite permitido pelas legislações vigentes para os parâmetros físico-químicos e eficiência de remoção de matéria orgânica representada pela demanda bioquímica de oxigênio (DBO5). Entretanto, as amostras apresentaram toxicidade aguda nos ensaios com Vibrio fischeri e Daphnia magna. A correlação de Pearson indicou que a toxicidade para a bactéria Vibrio fischeri foi positivamente relacionada com a concentração de alumínio (0,97) e cloro (0,93) e negativamente relacionada com a DBO5 (-0,73). A toxicidade para a Daphnia magna foi negativamente relacionada com o pH (-0,89) e a DBO5 (-0,95). Os organismos foram comparados quanto à sensibilidade aos parâmetros físico-químicos e a D. magna mostrou-se mais sensível aos parâmetros de pH e OD sendo que a bactéria luminescente V. fischeri apresentou-se mais sensível para cloro residual, DQO, DBO5, alumínio e nitrogênio amoniacal. / In Brazil various stations add aluminum polychloride on biological sludge to improve the efficiency of coagulation/flocculation and clarification and add sodium hypochlorite in the treated effluent for disinfection. In this study, analyses of samples in different operational conditions of a WWTP were performed. The samples were acquired in order to carry out assessments of physicochemical parameters and toxicity. The samples were within the limits allowed by legislation, such as the physicochemical parameters and the load organic matter (BOD5) removal efficiency. However, when toxicity assessments were performed using Vibrio fischeri and Daphnia magna, several samples showed toxicity factor. Pearson positive correlations indicated that toxicity by Vibrio fischeri was significantly correlated with the concentrations of aluminum (0.97) and chlorine (0.93) and negative correlations with the concentrations of biochemical oxygen demand (BOD5) (-0.73). The toxicity to D. magna was negatively correlated with the pH (-0.89) and the BOD5 (-0.95).The organisms were compared for sensitivity to physical and chemical parameters and Daphnia magna was more sensitive to the parameters of pH and do are the Vibrio fischeri had to be more sensitive to residual chlorine, COD, BOD5, ammonia nitrogen and aluminum. Regression models were adjusted for toxicity factor as dependent variable and physicochemical parameters as independent variables.
422

Sistema de tratamento híbrido utilizado na remoção do corante reativo 5g de um efluente têxtil sintético

Santos, Bruna Souza dos 25 March 2015 (has links)
CNPQ; Fundação Araucária; FPTI / Nos últimos anos observou-se um crescimento das atividades industriais que provocou impactos significativos aos recursos naturais, e as preocupações com o ambiente em geral adquirem especial importância. Neste contexto, a indústria têxtil considerada uma importante atividade responsável por parte desse desenvolvimento, se caracteriza como geradora de efluente líquido amplamente poluidor devido ao grande volume de água necessária nesse processo produtivo. Levando em consideração os métodos convencionais e também as dificuldades no tratamento dos efluentes têxteis, o processo eletrolítico conhecido como eletrofloculação se constitui em uma possibilidade importante. Este processo envolve a desestabilização de poluentes emulsificados, ou em suspensão, em meio aquoso. Desta forma o objetivo deste trabalho foi implantar um sistema de tratamento híbrido utilizado na remoção do corante reativo azul 5G de um efluente têxtil sintético, através da eletrofloculação associada a adição de coagulante natural a base de Moringa oleífera Lam, a fim de potencializar o nível de tratamento que seria alcançado com as técnicas utilizadas isoladamente Inicialmente trabalhou-se exclusivamente com a eletrofloculação para a remoção do corante. As variáveis analisadas foram: ddp (diferença de potencial aplicado), tempo e pH. Considerando o intervalo de confiança de 95% somente o termo quadrático da ddp e o termo linear do pH se mostraram significativos. Os valores de remoção da cor para os ensaios variaram de 64,38 a 90,87% e para a validação uma remoção média de 89,01%, valores muito próximos do predito pelo modelo. Na sequência foi realizada a otimização das condições para obtenção do extrato aquoso de Moringa oleífera. Avaliou-se as seguintes condições: salinidade e tempo de extração. A concentração do coagulante obtido, em água turva sintética também foi um dos fatores estudados. As melhores condições para o extrato aquoso de Moringa oleífera foram: 20 segundos de agitação em ultrassom, e solução de 20% em cloreto de sódio. Para potencializar o nível de tratamento as duas técnicas (eletrofloculação e coagulante natural a base de Moringa oleífera), foram testadas inicialmente em batelada e na sequência em fluxo contínuo. Os ensaios em batelada foram divididos em duas partes, o primeiro DCCR avaliou a intensidade de corrente elétrica (I), o tempo da eletrofloculação e a concentração do coagulante (MO), o qual obteve uma remoção de cor de 77,27% a 91,33%. Porém, nenhum termo foi significativo, mas o tempo apresentou menor efeito. Sendo assim, um novo planejamento foi realizado, o segundo DCCR, fixando o tempo na condição mínima, além das faixas de I e MO que também foram reduzidas. Obteve-se então uma remoção da cor para os ensaios de 13,45 a 80,8%, e para a validação uma remoção média de 86,56%. Para o módulo contínuo, as variáveis estudadas foram a intensidade de corrente elétrica (I), concentração do coagulante (MO) e tempo de retenção hidráulica (TRH). Dentre elas somente o TRH não se mostrou significativo. A remoção da cor variou de 8,46% a 90,25%. Nestes ensaios também foram realizados as análises das concentrações de Ferro Residual, e os valores obtidos variaram de 3,70 mg.L-1 a 9,03 mg.L-1, ficaram abaixo do valor máximo permissível pela Legislação (15 mg.L-1). Para maximizar a remoção da cor e minimizar a concentração de ferro residual, a função desejabilidade do software STATISTICA™ foi utilizada e nessas condições somente a I e a MO foram significativas. A partir da validação foi possível observar a tendência de remoção prevista pelo modelo. Obteve-se uma remoção da cor para a validação de 71,38% e uma concentração média de ferro residual de 5,2237 mg. L-1, porém, com um erro distante do esperado (32,85%). / In recent years there has been a growth of industrial activities that caused significant impacts to natural resources, and concerns about the environment in general are of particular importance. In this context, the textile industry considered an important activity responsible for part of that development is characterized as liquid effluent generating widely polluter due to the large volume of water needed in this production process. Taking into account the conventional methods and also the difficulties in treating textile effluents, the electrolytic process known as eletrofloculation constitutes an important possibility. This process involves the destabilization of the emulsified pollutants, or suspension in aqueous medium. Thus the aim of this study was to implement a hybrid treatment system used in removing the blue reactive dye 5G of a synthetic textile effluent by eletrofloculation associated with adding natural coagulant the basis of Moringa Oleifera Lam, in order to enhance the level treatment would be achieved with the techniques used alone initially worked up exclusively with eletrofloculation to remove the dye. The variables analyzed were: ddp (potential difference applied), time and pH. Whereas the 95% confidence interval only the quadratic term of the linear term DDP and pH were significant. The removal of color values for the tests ranged from 64.38 to 90.87% and validating an average removal of 89.01%, very close values predicted by the model. Following was carried out to optimize the conditions for obtaining the aqueous extract of Moringa oleifera. Salinity and extraction time: The following conditions were evaluated. The concentration of the coagulant obtained in synthetic turbid water was also one of the factors studied. The best conditions for the aqueous extract of Moringa oleifera were 20 seconds of ultrasound in agitation, and solution of 20% sodium chloride. To enhance the level of treatment the two techniques (eletrofloculation and natural coagulant Moringa oleifera the base), were initially tested in batch and following streaming. The batch tests were divided into two parts, the first CCRD evaluated the intensity of electric current (I), the time eletrofloculation and concentration of the coagulant (MO), which obtained a color removal of 91 to 77.27% 33%. But no term was significant, but time showed less effect. Thus, a new planning was done, the second CCRD, setting the time at a minimum, in addition to the R and MO tracks that were also reduced. There was thus obtained a removal color for testing 13.45 to 80.8%, and validating an average removal of 86.56%. For the continuous form, the variables studied were the intensity of electric current (I), the coagulant concentration (MO) and hydraulic retention time (HRT). Among them only HRT was not significant. The color removal ranged from 8.46 % to 90.25%. In these assays were also performed the analysis of the residual iron concentrations, and the values obtained ranged from 3.70 mg L- 1 to 9.03 mg.L-1, were below the maximum value allowable by law (15 mg.L-1). To maximize the removal of color and minimize the residual concentration of iron, the desirability function STATISTICA ™ software was used and under these conditions only I and MO were significant. From the validation was observed removing trend predicted by the model. Obtained was a color removal for the validation of 71.38 % and an average concentration of 5.2237 mg.L-1 of residual iron, but with a far from the expected error (32.85%).
423

Investigação do uso do processo fenton no tratamento terciário de efluente agroindustrial e na degradação do antibiótico norfloxacina

Almeida, Fernanda Salbego Colombari de 13 October 2014 (has links)
Capes / É crescente a presença de compostos persistentes, tais como fármacos, produtos de higiene pessoal, agrotóxicos, produtos de limpeza e derivados do petróleo, em efluentes industriais, por serem tóxicos causam uma série de danos ao meio ambiente, ao serem descartados de forma inadequada sem passar por um tratamento que os torne biodegradáveis. Em consequência, ocorre o aumento da contaminação de águas subterrâneas e de superfície, estações de tratamento de esgoto e de efluentes industriais. Em função disso, novas tecnologias capazes de degradar esta classe de compostos, como os processos de oxidação avançada, estão sendo investigadas, visto que os tratamentos mais comumente utilizados pelas indústrias, os biológicos, são incapazes de degradar compostos persistentes. Assim, o presente trabalho teve como objetivo principal investigar a eficiência da aplicação de um processo de oxidação avançada (Fenton) no tratamento terciário de um efluente de um frigorífico de suínos, e na degradação do antibiótico norfloxacina (NFX). Numa primeira etapa, o efluente agroindustrial foi caracterizado e os parâmetros operacionais do processo Fenton: pH de reação, razão [H2O2]/[DQO] (m/m), razão [Fe+2]/[H2O2] (m/m) e pH de coagulação foram investigados em função da eficiência de remoção de matéria orgânica, por meio da avaliação da demanda química de oxigênio (DQO). Em uma primeira etapa os parâmetros foram investigados por meio dos ensaios definidos em planejamento fatorial fracionário 24-1 com três repetições no ponto central e, após a definição dos parâmetros significativos (p ≤ 0,05), pH de coagulação e razão [Fe+2]/[H2O2] (m/m), esses foram novamente investigados por meio do Delineamento Central Composto Rotacional (DCCR) 22, com três pontos centrais e quatro pontos axiais. A máxima remoção de DQO alcançada foi de 67,71%. Posteriormente realizou-se um estudo, no qual o antibiótico NFX foi submetido ao tratamento pelo processo Fenton. As variáveis [H2O2] e [Fe+2] foram investigadas por meio de um planejamento DCCR, 22, com três pontos centrais e quatro pontos axiais. A eficiência do processo foi avaliada em função da porcentagem de degradação do fármaco, avaliada a partir da sua concentração no decorrer do processo. A máxima degradação do fármaco alcançada foi de 96,41% para tempo reacional de 5 s e, após 10 s de reação a NFX já não foi mais detectada. A avaliação da cinética de degradação da NFX pelo processo Fenton foi investigada e o comportamento de pseudo-segunda ordem foi observado. A partir análise dos resultados obtidos, com remoções satisfatórias de matéria orgânica e NFX pelo processo Fenton, pode-se concluir de forma geral que esse processo é promissor para o tratamento terciário de efluentes agroindustriais com o objetivo de degradação de compostos persistentes ao tratamento biológico normalmente empregado nas indústrias de alimentos. / There is a growing presence of persistent compounds, such as pharmaceuticals, personal care products, pesticides, cleaning products, and petroleum in industrial wastewaters to be toxic cause a lot of damage to the environment, when improperly discarded without undergo a treatment that makes them biodegradable. As a result, is increase of contamination of groundwater and surface water, sewage treatment plants and industrial wastewater . Because of this, new technologies capable of degrading this class of compounds, such as advanced oxidation processes, are being investigated, since the treatments most commonly used by industries, biological, are unable to degrade persistent compounds. Thus, the present study aimed to investigate the effectiveness of applying an advanced oxidation process (Fenton) in the tertiary treatment of wasterwaters from a swine slaughterhouse, and the degradation of the antibiotic norfloxacin (NFX). In a first step, the agro-industrial wasterwater and wherein the operating parameters of the process Fenton reaction pH, ratio [H2O2]/[COD] (w / w) ratio [Fe + 2]/[H2O2] (w/w) pH and coagulation were investigated depending on the removal efficiency of organic matter, through the evaluation of chemical oxygen demand (COD). In a first step the parameters were investigated by means of tests defined in 24-1 fractional factorial design with three replications at the center point and, after the definition of significant parameters (p≤0.05), pH and coagulation ratio [Fe + 2]/[H2O2] (w/w), these were again investigated by means of the rotational central composite design (RCCD) 22 with three center points and four axial points. The maximum COD removal achieved was 67.71%. Subsequently we performed a study in which the antibiotic norfloxacin was subjected to treatment by the Fenton process. The variables [H2O2], and [Fe 2 +] was investigated by means of a RCCD 22design with three center points and four axial points. Process efficiency was evaluated according to the percentage of degradation of the drug assessed from its concentration in the process. The maximum degradation of the drug achieved was 96.41% for reaction time of 5 if, after 10 s of reaction to NFX was no longer detected. The evaluation of the degradation kinetics of norfloxacin by Fenton process was investigated and the behavior of the pseudo-second order was observed. From analysis of the results obtained with satisfactory removal of organic matter and norfloxacin the Fenton process, it can be concluded that in general this process is promising for tertiary treatment of agroindustrial wasterwater for the purpose of degradation of the biological treatment persistent compounds usually employed in the food industries.
424

Pré-tratamento de efluente de curtume por bactérias e enzima lipolíticas

Lima, Vivian de Oliveira 07 July 2015 (has links)
As águas residuárias industriais possuem propriedades físico-químicas distintas, sendo necessários estudos específicos para a escolha do tratamento de cada efluente visando garantir maior eficiência e atendimento aos requisitos ambientais. Diversas indústrias, dentre elas o Curtume, potencialmente, geram efluentes com elevado teor de óleos e gorduras (O&G). Tais compostos podem causar problemas operacionais e interferir no desempenho dos sistemas biológicos de tratamento. Por esse motivo, a remoção preliminar de O&G, em geral, é recomendada. A hidrólise enzimática de lipídios tem se mostrado promissora no pré-tratamento de águas residuárias como alternativa ao uso de métodos físico-químicos. O objetivo deste trabalho foi isolar bactérias lipolíticas do efluente da graxaria de curtume, aplicá-las no pré-tratamento deste efluente em escala laboratorial e comparar seus efeitos com o uso do produto comercial Enzilimp® e com enzima LPP (lipase de pâncreas de porco - Sigma Aldrich®). Foram isoladas 14 cepas produtoras de lipase. A cepa MOV7 (estafilococo positivo), que apresentou maior índice enzimático, foi utilizada nos ensaios. Foram realizados três ensaios preliminares com o intuito de avaliar o perfil temporal e a influência da concentração dos inóculos, dos efeitos da diluição do efluente e da aeração. Posteriormente realizou-se o DCCR avaliando a influência da temperatura, da concentração do inóculo, da concentração do efluente e do pH para as variáveis respostas DQOt, DQOs, O&G e Índice de Acidez ao longo de 48 horas em sistema fermentativo e posteriormente 24 horas em sistema aerado. Ao final do experimento concluiu-se que o efluente da graxaria do curtume é fonte potencial de bactérias lipolíticas e que tais cepas isoladas apresentam comportamento semelhante ao Enzilimp®. Após 72 horas de experimento (48 horas em período fermentativo e 24 horas em sistema aerado) foram alcançadas remoções de 75% de O&G e 47% de DQOt com MOV7 e 52% de O&G e 30% DQOt com a enzima LPP. A enzima LPP provocou aumento de 1,1g de DQOt por g de enzima adicionada. Quando in natura, o aumento da concentração dos inóculos não resultou em melhoria do tratamento. Porém, a diluição do efluente favoreceu a redução dos parâmetros DQO, O&G e IA para os diferentes inóculos. A aeração favoreceu a redução da matéria orgânica nas diluições entre 12,5 e 62,5 mL.L-1. Observou-se que a temperatura e pH influenciaram significativamente o desempenho do sistema com melhores resultados a 30°C e 8,0, respectivamente. / Industrial wastewaters present different physiochemical characteristics, requiring specific studies for choose the correct treatment for each effluent, ensuring more efficiency, taking into account environmental requirements. Many kinds of industries, including tannery, potentially produce effluents with high content of oil and grease (O&G). Those compounds can cause operational problems and interfere on the performance of biological treatment systems. For these reasons, in general, is recommended the preliminary removal of O&G. The enzymatic hydrolysis of lipids has proven promising in pretreatment of wastewaters like an alternative for physiochemical methods. The aim of this study was isolate microorganisms from tannery effluent able to produce extracellular lipase, apply them in the pretreatment in laboratorial scale of this effluent and compare their effects with the commercial product Enzilimp® and with PPL enzyme (porcine pancreas lipase Sigma Aldrich®). Were isolate 14 strains from tannery's effluent. The strain MOV7 (positive staphylococci), that presented the greatest enzymatic index, was used on the tests. Were done three preliminary tests with the objective to evaluate the time and the influence from inoculum concentration, from effluent dilution and aeration. After, were made the DCCR to evaluating the influence from temperature, inoculum and effluent concentration, and pH on the variables responses CODt, CODs, O&G e Acid Index during 48 hours in fermentation system and 24 hours after in aerobic system. In the end of the tests were concluded that the tannery effluent is a potential source of lipolytic bacteria and those strains have similar behavior to Enzilimp®. During 72 hours (48 hours in fermentative conditions and 24 in aerated conditions) the pretreatment reached the reduction of 75% of O&G and 47% of CODt with MOV7 and 52% of O&G and 30% with PPL enzyme. The PPL enzyme caused the increasing of 1,1g CODt on each gram from added enzyme. When in natura, the increasing of inoculum concentration gave no better results on treatment. However, the effluent dilution promoted the decreasing of parameters COD, O&G and AI for the different inoculums. The aeration was effective on reduction from organic matter in dilutions between 12,5 and 62,5 mL.L-1. Was observed that the temperature and pH influenced significatively the system's work with better results on 30°C and 8,0, respectively.
425

Emprego dos processos de eletrofloculação e osmose inversa no tratamento de águas oleosas / The use of electroflocculation and reverse osmosis in the treatment of oily wastewater

Leonardo Firmino da Silva 26 February 2013 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / A descarga desenfreada de águas residuais no meio ambiente, ao longo dos últimos anos, vem acelerando o processo de contaminação e degradação dos corpos hídricos no mundo. Tais rejeitos apresentam elevada carga de contaminantes e de concentração de matéria orgânica o que leva a mortandade das espécies pela concorrência ao oxigênio e, em casos extremos, a aceleração dos processos de eutrofização. Pensando nisso, o presente trabalho estudou um sistema híbrido, em batelada, de tratamento de águas oleosas simuladas em laboratório pela adição de um determinado óleo lubrificante em uma solução aquosa de agentes emulsificantes e eletrólito suporte. O sistema de tratamento foi composto de duas etapas, onde na primeira avaliou-se o uso da técnica da eletrofloculação, responsável por quebrar a estabilidade das emulsões óleo/água e de uma segunda que avaliou o uso de processos de separação com membranas visando à remoção do metal adicionado ao efluente na etapa anterior. O sistema de eletrofloculação foi avaliado em relação ao uso de eletrodos de alumínio e ferro com correntes elétricas de 1A, 2A e 3A, nos modos contínuo e alternado. Os resultados apontaram um maior consumo evidente de massa de eletrodos quando do uso da corrente contínua, 4,0337g 0,0132 para o alumínio e 3,8260g 0,0181 para o ferro ao passo que o consumo foi de 2,1400g 0,0099 para o alumínio e 2,4121g 0,0127 para o ferro quando do o uso da corrente alternada. Foram alcançadas remoções máximas de 98 % 0 da DQO, 99,77 % 0,27 de remoção da cor e 100 % 0 de remoção da turbidez para o uso de corrente alternada e eletrodos de alumínio enquanto se alcançaram remoções máximas 96 % 1 da DQO, 99,46 % 0,82 de remoção da cor e também 100 % 0 de remoção da turbidez no uso de eletrodos de ferro. Na segunda etapa do estudo, a osmose inversa, o sistema utilizado atingiu rejeições de 99,53 % 0,12; 99,56 % 0,13 e de 98,87 % 0,36, para pressões respectivas de 10, 20 e 30 bar. Além disso, foram obtidos fluxos crescentes de permeado 10,87 L/h.m2 0,25; 15,67 L/h.m2 0,53; 18,49 L/h.m2 0,74 com o também aumento da pressão. Ao final do estudo alcançou-se um efluente final com baixa carga orgânica e de metais, estando o mesmo apto ao lançamento nos corpos receptores. Entretanto, mecanismos de controle, sobretudo de pH devem ser incluídos no projeto desses sistemas uma vez que esse parâmetro sofre alterações ao longo do processo / The uncontrolled discharge of wastewater into the environment over the last years has accelerated the process of contamination and degradation of water bodies in the world. These wastes contain high amounts of contaminants and concentration of organic matter which leads to the death of several species due to lack of oxygen and, in extreme cases, acceleration of eutrophication processes. In the specific case of oily wastewater, the use of techniques such as chemical coagulation, dissolved air injection, membranes, biochemical and electrochemical processes are described. However some of these processes have limitations which range from the concentration of the contaminant in the effluent, limitations in the operating conditions and even cost constraints. With this in mind, this paper has studied a hybrid system, batch process, in the treatment of oily waters simulated in the laboratory by adding a specific lubricating oil in an aqueous solution with emulsifiers and supporting electrolyte. The treatment system was consisted of two stages, which in the first was evaluated the use of the technique of electrocoagulation, which was responsible by the breaking stability of oil/water emulsions and a second stage which evaluated the use of membrane separation processes in order to remove the metal added to the effluent in the previous stage. The electrofloculation system was evaluated in relation to the use of iron and aluminum electrodes with electrical currents of 1A, 2A and 3A, in the continuous and alternate modes. The results showed a higher apparent mass consumption of electrodes when using direct current, 4,0337 g 0,0132 for aluminum and 3,8260 g 0,0181 for iron while consumption was 2,1400 g 0,0099 for aluminum, and 2,4121 0,0127 g for the iron when the use of alternating current. Removals were reached maximum 98 % 0 COD, 99,77 % 0,27 color removal and 100 % 0 turbidity removal for use alternating current and aluminum electrodes while were reached maximum 96 % 1 of COD, 99,46 % 0, 82 color removal and also 100% 0 to remove the turbidity in the use of iron electrodes. In the second study phase, reverse osmosis, the system used has reached rejections 99,53 % 0,12, 99,56 % 0,13 and 98,87 % 0,36, corresponding to pressures of 10 , 20 and 30 bar Moreover, increasing flows were obtained permeate 10,87 L/h.m2 0,25, 15,67 L/h.m2 0,53; 18,49 L/h.m2 0,74 also with the increased pressure. At the end of the study was reached final effluent with low organic load and metals, it being able to release the bodies receptors. However, control mechanisms, particularly pH should be included in the design of such systems since this parameter changes over the process
426

Pesquisa de ovos de helmintos em lodo de esgoto oriundo de Campo Grande (MS) após tratamento anaeróbico

Carrijo, Juliana Rosa [UNESP] January 2004 (has links) (PDF)
Made available in DSpace on 2014-06-11T19:30:11Z (GMT). No. of bitstreams: 0 Previous issue date: 2004Bitstream added on 2014-06-13T18:59:54Z : No. of bitstreams: 1 carrijo_jr_me_botfmvz.pdf: 944836 bytes, checksum: d88e0ef5ec50a863f75fe35cebbc250a (MD5) / Universidade Estadual Paulista (UNESP) / O crescimento da população urbana tem produzido um aumento progressivo de resíduos sólidos, que após sofrerem vários processos de desinfecção denominam-se biossólidos. Esta massa orgânica pode ser destinada a diversas finalidades, inclusive como fertilizante agrícola. Entretanto, a disposição deste material deve seguir padrões de qualidade, por apresentar organismos nocivos aos homens e animais. O objetivo deste trabalho foi avaliar a presença de ovos de Taenia sp em lodo de esgoto, previamente tratado em sistema de digestão anaeróbia do tipo Reator Anaeróbio de Lodo Fluidizado (RALF). As amostras de lodo de esgoto foram colhidas na unidade Aero Rancho de Tratamento de Esgoto (ETE) Águas Guariroba, em Campo Grande-MS. O experimento foi dividido em duas fases. Na primeira etapa foram avaliados diferentes tipos de materiais para a escolha do filtro, que possibilitasse a passagem de ovos de Taenia saginata diluídos em água destilada e em lodo líquido. O filtro que melhor se adequou ao experimento foi o Papel higiênico fino folha única. As amostras de lodo de esgoto foram colhidas nos dias 1 (líquido), 15 e 30 (sólido). O lodo colhido foi dividido em alíquotas e filtrado no Papel higiênico fino folha única. Após centrifugação foram avaliadas três lâminas do sedimento por amostra. Os ovos de helmintos foram classificados pelo seu gênero, segundo sua morfologia similar. Foram encontrados ovos com morfologia similar a de ovos de ancilostomídeos, ascarídeos e estrongilídeos em todas as colheitas. Os ovos de Taenia sp, Trichuris, Dipylidium e Strongyloides foram encontrados somente em uma das colheitas. O número de ovos de nematóides prevaleceu sobre os de cestóides. Foram listados ainda, outros organismos como, ácaros, coccídeos, larvas de nematódeos mortas e vivas, leveduras, oocisto e organismos de vida livre. A quantidade de ovos... . / The urban population growth have been produced a progressive increase of solid residue that after being through many treatment process is called biossolid. This organic mass can be destination to many use, specially as agricultural fertilizer. However, the disposal of this material must follow some quality standard, for presents harmful organisms to men and animals. The objective of this work was to evaluate the Taenia sp eggs in sewage sludge, previously treated in anerobic digestion process like anaerobic liquid fluid reactor (RALF). The solid sludge samples were collected at the Aero Rancho unit of sludge treatment - Águas Guariroba in Campo Grande, MS. The experiment was devided in two phases. In the first phase were evaluate different kinds of materials to choose the filter, which permit to filter the Taenia saginata eggs diluted with distilled water and in liquid sludge. The filter that better adapted in the experiment was the fine toilet paper one sheet. The sewage sludge samples were collected in the days one (liquid), 15 and 30 (solid). The sludge collected were divided in aliquot and filtered with fine toilet paper one sheet. After, centrifuged it was evaluated three sheet from the sediment for sample. The helminth eggs were classified for their genera, like their similar morphology. There were ancilostomideos, ascarídeos and estrongilídeos eggs in all collect. Eggs of Taenia sp, Trichuris, Dipylidium and Strongyloides were founded only in one of the collects. The nematodes eggs prevailed on the cestodes. Still were listed another organisms as acaros, leavenings, larvae organisms alive and dead, oocists and others organisms. The amount of helminth eggs were varied, indicating the necessity of the sewage sludge pass trough other complementary treatments process, like been revolved and storage for longer period of time. Concluded that the fine... (Complete abstract, click electronic address below).
427

Fotoeletrooxidação na degradação de nonilfenol etoxilado em águas residuárias

Silva, Salatiel Wohlmuth da January 2013 (has links)
Os poluentes orgânicos emergentes (POE) são compostos químicos presentes numa variedade de produtos comerciais como medicamentos, produtos de higiene, agrotóxicos, surfactantes, dentre outros, podendo ser encontrados em matrizes ambientais e biológicas. Esses poluentes não são usualmente monitorados ou ainda não possuem legislação regulatória correspondente, mas apresentam risco à saúde humana e ao meio ambiente. Dentre esses POE, podemos destacar o nonilfenol etoxilado, um surfactante não-iônico utilizado no desengraxe alcalino da indústria de galvanoplastia. Esse surfactante possui uma recalcitrância e toxidade que aumenta com a diminuição do número de grupos etoxilados, processo que ocorre quando ele é biodegradado. Alguns dos produtos da biodegradação são o nonilfenol com 4, 3, 2 ou 1 grau de etoxilação e nonilfenol, este considerado disruptor endócrino imitando o hormônio natural 17β-estradiol. Tratamentos convencionais de efluentes e água não são eficientes para degradação completa desses compostos. O emprego de processos mais eficientes, como processos oxidativos e oxidativos avançados tais como a Eletrólise (E), Fotólise direta (F), Fotocatálise heterogênea (FH) e a fotoeletrooxidação (FEO), tecnologias limpas que utilizam o elétron e o fóton como reagentes, têm sido proposto como opção para a degradação desses compostos, evitando assim a contaminação dos recursos hídricos. Este trabalho foi realizado com uma solução baseada na composição de um efluente industrial contendo nonilfenol etoxilado com 4 graus de etoxilação. Os ensaios de FEO foram realizados em triplicata, variando-se a densidade de corrente, potência de lâmpada e o tempo de tratamento. Além disso, foram realizados, para efeito de comparação e elucidação de mecanismos, ensaios de eletrólise, fotólise direta e fotocatálise heterogêna. As amostras coletadas antes e após os processos oxidativos foram caracterizadas por diferentes métodos analíticos e por toxicidade. Verificou-se que no tempo de tratamento de 240 minutos as diferentes configurações de FEO não foram suficientemente eficazes na degradação de todo o poluente que se encontra na solução inicial, entretanto, a configuração FEO3 não gerou metabólitos mais tóxicos, não apresentou diferença de germinação e de crescimento de raiz, não apresentando também citotoxicidade e genotoxicidade em alface e em cebola, apresentando toxicidade apenas em peixes em uma concentração de 70,71%, o que pode ser evitado com o aumentando do tempo de tratamento, à vista disso, o processo de FEO torna-se uma opção na degradação do nonilfenol etoxilado e de outros POE, evitando assim que esses atinjam os recursos hídricos. / The emerging organic pollutants (POE) are chemical compounds present in a variety of commercial products such as medicines, toiletries, pesticides, surfactants, among others, can be found in environmental and biological matrices. These pollutants are usually not monitored or have no corresponding regulatory legislation, but present risk to human health and the environment. POE Among these, we highlight the nonylphenol ethoxylate, one non-ionic surfactant used in degreasing alkaline electroplating industry. This surfactant has a recalcitrance and toxicity increases with the decrease of the number of ethoxylate groups, a process which occurs when it is biodegraded. Some of the products of biodegradation are nonylphenol with 4, 3, 2 or 1 degree of ethoxylation of nonylphenol and this considered endocrine disruptor mimicking the natural hormone 17β -estradiol. Conventional treatment of sewage and water are not efficient for complete degradation of these compounds. The use of more efficient processes, such as oxidation and advanced oxidation processes such as direct photolysis (F), Electrolysis (E), heterogeneous photocatalysis (FH) and photoelectrooxidation (FEO), clean technologies that utilize the electron and photon reagents have been proposed as an option to the degradation of such compounds, thereby avoiding the contamination of water resources. This work was carried out with a solution based on the composition of an industrial effluent containing nonylphenol ethoxylate with 4 degrees of ethoxylation. FEO assays were performed in triplicate, by varying the current density lamp power and treatment time. In addition, we performed, for comparison and elucidation of mechanisms, testing electrolysis, photolysis and photocatalysis heterogenous. The samples collected before and after the oxidative processes were characterized by different analytical methods and toxicity. It was found that treatment time of 240 minutes, the FEO different configurations were not efficient enough to degrade any pollutants that is in the initial solution, however, the configuration FEO3 not more toxic metabolites generated no significant difference in seed germination and root growth, no significant cytotoxicity and genotoxicity also in lettuce and onion, showing toxicity on fish only at a concentration of 70.71 %, which can be avoided by increasing treatment time, the sight, the process of FEO becomes an option in the degradation of nonylphenol ethoxylate and other POE, thus preventing it reaches the water.
428

Cartografia geotécnica aplicada aos riscos de alagamento e inundação na bacia do rio São Bartolomeu

Batista, Pedro Henrique Lopes 14 February 2014 (has links)
Dissertação (mestrado)—Universidade de Brasília, Faculdade de Tecnologia, Departamento de Engenharia Civil e Ambiental, 2014. / Submitted by Larissa Stefane Vieira Rodrigues (larissarodrigues@bce.unb.br) on 2014-10-24T16:46:08Z No. of bitstreams: 1 2014_PedroHenriqueLopesBatista.pdf: 49729216 bytes, checksum: e23ee681a7c3f765804073f8b266f4e9 (MD5) / Approved for entry into archive by Raquel Viana(raquelviana@bce.unb.br) on 2014-10-29T09:40:17Z (GMT) No. of bitstreams: 1 2014_PedroHenriqueLopesBatista.pdf: 49729216 bytes, checksum: e23ee681a7c3f765804073f8b266f4e9 (MD5) / Made available in DSpace on 2014-10-29T09:40:18Z (GMT). No. of bitstreams: 1 2014_PedroHenriqueLopesBatista.pdf: 49729216 bytes, checksum: e23ee681a7c3f765804073f8b266f4e9 (MD5) / O acúmulo das águas pluviais em perímetros urbanos e o extravasamento das águas da calha de uma drenagem, respectivamente, alagamentos e inundações, são fenômenos frequentes, contudo previsíveis em relação aos demais desastres naturais. Diversos atributos do meio físico influenciam os processos de alagamento e inundação. A motivadora Política Nacional de Proteção e Defesa Civil objetiva apoiar o mapeamento e análise dos riscos e suas aplicações. Então, a partir da definição da bacia hidrográfica do rio São Bartolomeu como área de estudo e aplicando o arcabouço teórico metodológico da análise de riscos geotécnicos e cartografia geotécnica, apoiados por ferramentas de geoprocessamento, o trabalho foi realizado de modo prático e racional para os fenômenos. Foram coletados diversos dados geoespaciais, em diferentes escalas, para o reconhecimento completo dos atributos do meio físico e por meio do método de análise hierárquica para construir cenários de suscetibilidade. O inventário de alagamentos e inundações para o Distrito Federal (DF) foi realizado tomando matérias jornalísticas totalizando então 14 anos. Análises probabilísticas definiram o perigo a alagamentos e inundações baseadas no acumulado de precipitação pluviométrica como deflagrante do fenômeno estudado. As vulnerabilidades e consequências foram estimadas, ao definir os elementos em risco (as infraestruturas), de forma subjetiva em função das suas fragilidades, nível de implantação do sistema de drenagem pluvial e custos unitários de construção e reabilitação. O risco foi definido como o produto do perigo, danos e prejuízos (vulnerabilidade e consequências). Foram obtidos 385 pontos de ocorrência a alagamentos e inundações, com grande concentração no Plano Piloto de Brasília/DF. A maior parte dos pontos expressa fenômenos de alagamento e o acumulado de chuva deflagrante teve uma média de 46 mm/24h. Os maiores valores de perigo observados estão concentrados na Asa Norte de Brasília/DF. Foram obtidos 10 cenários de suscetibilidade a alagamento e inundação. Os atributos do meio físico, que apresentaram os cenários de maior consistência, foram declividade, curvatura do terreno, escoamento superficial e a distância de drenagem dividida pela área de fluxo acumulado. Regiões com sistemas de drenagem pluvial implantados parcialmente - ou não existentes - apresentaram os maiores valores monetários nas estimativas ilustradas nas cartas de risco. _______________________________________________________________________________________ ABSTRACT / The accumulation of stormwater in urban perimeters and the overflow of water from a channel river, denominated as general floods, are frequent phenomena, although predictable compared to the others natural disasters. Several terrain attributes influences the processes of flooding and inundation. The National Policy on Protection and Civil Defense aims to support the risk mapping, evaluation and studies and their others appliances. Then, from the definition of a St. Bartolomeu river watershed as the study area and applying the theoretical and methodological framework of geotechnical risk analysis and geotechnical mapping, supported by GIS tools, the work was done in a practically and rationally approach for the phenomena. Several geospatial data, on different scales, were collected for terrain attributes entire recognition and by means of Analytical Hierarchy Process susceptibility scenarios were built. An inventory of flooding occurrences for the Federal District (DF) of Brazil was performed acquiring 14 years newspaper articles. Probabilistic analysis defined the flood hazard by means of phenomenon trigger cumulative rainfall. The vulnerabilities and consequences were estimated, defining the elements at risk (the infrastructures), subjectively according to their fragility, the accomplishment level of the stormwater drainage and construction and rehabilitation unit costs. The risk was defined as the product of hazard and damages (vulnerability and consequences). 385 flooding occurrence points were obtained, with a larger concentrationăinăPlanoăPilotoăofăBrasília/DF.ăTheămajorăpoint’sălotăexpressedăthe phenomena of accumulation of stormwater in terrain, not associated with rivers, and the mean value of the trigger cumulative rainfall was 46 mm/24h. The highest hazard values observed are concentrated on Asa Norte of Brasília/DF. 10 susceptibility scenarios of flooding and inundation were obtained. The terrain attributes, which presented the greater consistency scenarios, were slope, curvature, runoff and drainage buffer divided by contributing area. Regions with the stormwater drainage systems partially implemented - or nonexistent - exhibited the highest monetary values illustrated in the risk maps estimates.
429

Remoção de oocistos de Cryptosporidium por meio da filtração direta ascendente em areia : avaliação em escala piloto.

Nascimento, Marcely Ferreira 21 December 2009 (has links)
Dissertação (Mestrado em Tecnologia Ambiental e Recursos Hídricos)-Universidade de Brasília, Brasília, 2009. / Submitted by Luiza Moreira Camargo (luizaamc@gmail.com) on 2011-07-05T16:33:30Z No. of bitstreams: 1 2009_MarcelyFerreiraNascimento.pdf: 4078879 bytes, checksum: c6e557f5165ad0b2f47fa09946ad8df4 (MD5) / Approved for entry into archive by Jaqueline Ferreira de Souza(jaquefs.braz@gmail.com) on 2011-07-08T14:41:28Z (GMT) No. of bitstreams: 1 2009_MarcelyFerreiraNascimento.pdf: 4078879 bytes, checksum: c6e557f5165ad0b2f47fa09946ad8df4 (MD5) / Made available in DSpace on 2011-07-08T14:41:28Z (GMT). No. of bitstreams: 1 2009_MarcelyFerreiraNascimento.pdf: 4078879 bytes, checksum: c6e557f5165ad0b2f47fa09946ad8df4 (MD5) / Dentre as doenças de veiculação hídrica que vêm recebendo maior atenção nos últimos anos, destaca-se a Criptosporidiose que é causada pelo protozoário Cryptosporidium. Os oocistos de Cryptosporidium são resistentes ao estresse ambiental e à inativação por cloro e, devido ao seu tamanho, têm facilidade para passar através do processo de tratamento físico de água. Nesse contexto, o presente trabalho teve como objetivo avaliar a remoção de oocistos de Cryptosporidium parvum por meio da filtração direta ascendente em areia. Os experimentos de filtração direta ascendente, em escala piloto, foram realizados com água proveniente do Lago Paranoá inoculada com oocistos de Cryptosporidium parvum de modo a se obter concentração da ordem de 103 ooc./L na água de estudo. A taxa de filtração adotada foi de 120m³/m².d. Em nove experimentos de filtração a água de estudo apresentava valores baixos de turbidez (2,7 a 4,8 UT) e em três experimentos a turbidez era de cerca de 30 UT. Os resultados revelaram que a eficiência de remoção de oocistos de Cryptosporidium parvum no início do experimento de filtração foi, em média, 0,5 log menor que no período de funcionamento estável, em que a remoção média de oocistos de Cryptosporidium parvum foi de 3,5 log. Os valores de turbidez na água filtrada foram inferiores ao limite de 0,5 UT recomendado na legislação brasileira, Portaria MS No. 518/2004, e também inferiores ao limite da legislação americana (0,3 UT), exceto nos experimentos com turbidez mais elevada. A concentração de oocistos de Cryptosporidium parvum na água de lavagem do filtro confirmou o elevado risco de contaminação microbiológica desse resíduo. O tratamento estatístico dos dados indicou que na água filtrada não houve correlação significativa entre a concentração de oocistos de Cryptosporidium parvum e os parâmetros turbidez, coliformes totais e E.coli. Correlação fraca foi observada entre oocistos de Cryptosporidium parvum e contagem de partículas nas faixas de tamanho do oocisto de Cryptosporidium. Os resultados revelam que os filtros rápidos ascendentes apresentam eficiências de remoção de oocistos de Cryptosporidium parvum similares aos filtros rápidos descendentes. _______________________________________________________________________________ ABSTRACT / Among the waterborne diseases that have received increased attention in recent years stands out Cryptosporidiosis, which is caused by the parasite protozoan Cryptosporidium. Cryptosporidium oocysts are resistant to environmental stress and inactivation by chlorine and, due to their size,, may pass through the physical treatment processes of water. In this context, this study aimed to evaluate the removal of Cryptosporidium oocysts by up flow direct sand filtration. The experiments in pilot scale were carried out with Paranoá lake water spiked with Cryptosporidium parvum oocysts in order to obtain concentration of about 103 ooc./L in the study water. The filtration rate adopted was 120m³/m².d. In nine experiments the study water presented low levels of turbidity (2.7 to 4.8 NTU) and in three experiments the turbidity was of around 30 NTU. The results showed that the removal efficiency of Cryptosporidium parvum oocysts in the early stages of the filtration experiments was, in average 0.5 log lower than during filtration steady state where the average removal of Cryptosporidium parvum oocysts was 3.5 log. The values of turbidity in filtered water were below the limit of 0.5 NTU recommended by UT Brazilian Health Authority, Decree MS No. 518/2004, and also below the limit set by U.S. legislation (0.3 NTU), except in experiments with study water with higher turbidity. The concentration of Cryptosporidium parvum oocysts in the filter backwash water confirmed the high risk of microbiological contamination of the this waste. Statistical analysis indicated that there was no significant correlation between the concentration of Cryptosporidium parvum oocysts and characteristics such as turbidity, total coliform and E.coli in the filtered water. Weak correlation was found between Cryptosporidium parvum oocysts and particle counting in size range of Cryptosporidium oocyst. The results suggest that up flow direct filtration has similar removal efficiency of Cryptosporidium oocysts when compared with down flow filtration.
430

Detecção de metalo beta-lactamases e similaridade genética em isolados de Pseudomonas aeruginosa de efluente hospitalar e água superficial / Detection of metallo β-lactamases and genetic similarity in Pseudomonas aeruginosa isolates from hospital sewage and superficial water

Fuentefria, Daiane Bopp January 2009 (has links)
A presença de Pseudomonas aeruginosa resistentes a antimicrobianos no esgoto hospitalar contribui para sua disseminação em corpos d´água e possibilita o estabelecimento de reservatórios ambientais de resistência bacteriana. Os objetivos deste estudo foram comparar isolados de P. aeruginosa de amostras de esgoto hospitalar e água superficial quanto ao perfil de susceptibilidade aos antimicrobianos, a presença e diversidade de genes de metalo β-lactamases (MBLs) e a similaridade genética entre os isolados. Para isso, as amostras de esgoto hospitalar foram coletadas de cinco hospitais, localizados em Passo Fundo e Porto Alegre, RS, Brasil. As amostras de água superficial foram coletadas dos corpos d´água que recebem os esgotos de dois hospitais estudados. Os isolados foram identificados por provas bioquímicas clássicas e pela amplificação de um fragmento do rDNA 16S. O perfil de susceptibilidade foi avaliado pela técnica de disco-difusão. Os genes blaSPM-1, blaVIM e blaIMP foram pesquisados por PCR. A relação clonal entre os isolados foi avaliada pela ERIC-PCR e PFGE. A diversidade nos genes de MBLs encontrados foi avaliada pela DGGE. Foram analisados 614 isolados de P. aeruginosa, dos quais somente 5,0% apresentaram o gene blaSPM-1. Todos os isolados com este gene apresentaram fenótipo de multirresistência. A análise de similaridade genética pela ERIC-PCR e PFGE não mostrou relação clonal entre isolados de água superficial e esgoto hospitalar ou entre isolados provenientes de amostras de diferentes esgotos hospitalares. A presença de isolados resistentes e com o gene blaSPM-1, em amostras de esgoto hospitalar, atenta para o risco de disseminação ambiental de resistência bacteriana. / The presence of Pseudomonas aeruginosa resistant to antimicrobials in hospital sewage contributes to its dissemination into water bodies and may lead to the establishment of environmental reservoirs of bacterial resistance. The objectives of this study were to compare P. aeruginosa strains isolated from hospital sewage and superficial water samples, about the susceptibility profile to antimicrobials, the presence and diversity of the metallo β-lactamases (MBLs) genes and the genetic similarity among the strains. For this purpose, hospital sewage samples were collected from five hospitals located in Passo Fundo and Porto Alegre, RS, Brazil. The superficial water samples were collected from the water bodies where the sewage from two of the analyzed hospitals were discharged. The isolates were identified by classical biochemical tests and amplification of 16S rDNA fragment. The susceptibility was determined by the disk-diffusion method. The blaSPM-1, blaVIM e blaIMP genes were screened by PCR. The clonal relationship among the strains was evaluated by ERIC-PCR and PFGE. The diversity on MBL genes found was analyzed by DGGE. A total of 614 P. aeruginosa strains were analyzed, of which only 5,0 % showed the blaSPM-1 gene. All isolates with this gene showed the multirresistance phenotype. The genetic similarity analysis by ERIC-PCR and PFGE didn´t show clonal relationship between the strains from superficial water and hospital sewage or between the strains from samples of different hospital sewages. The presence of resistant isolates and isolates with the blaSPM-1 gene in hospital sewage samples call attention to the risk of environmental dissemination of bacterial resistance.

Page generated in 0.0528 seconds