Spelling suggestions: "subject:"águas residuais purificação"" "subject:"águas residuais urificação""
111 |
Fatores associados aos parâmetros ajustados na equação de cinética de primeira ordem modificada utilizada em sistemas alagados construídos / Factors associated whit the parameters set on the modified first order of kinetic equation used in constructed wetlandsCosta, Renan de Almeida 12 February 2016 (has links)
Submitted by Marco Antônio de Ramos Chagas (mchagas@ufv.br) on 2016-07-08T17:19:31Z
No. of bitstreams: 1
texto completo.pdf: 3542099 bytes, checksum: 22150f7209aa6581ebda209f34507ebd (MD5) / Made available in DSpace on 2016-07-08T17:19:31Z (GMT). No. of bitstreams: 1
texto completo.pdf: 3542099 bytes, checksum: 22150f7209aa6581ebda209f34507ebd (MD5)
Previous issue date: 2016-02-12 / O presente trabalho teve por objetivo avaliar a relação entre o parâmetro de potência do tempo de detenção hidráulica (n), do modelo matemático de cinética de primeira ordem modificado por Brasil et al. (2007), com o número de dispersão hidráulica (d) e também com o comportamento da degradabilidade do material orgânico, obtida a partir da relação DQO/DBO, ao longo do comprimento de sistemas alagados construídos de escoamento horizontal subsuperficial (SAC-EHSS). Para isto, foram utilizados SACs-EHSS não plantados, de iguais volumes, mas com configurações geométricas distintas, denominados SAC1, SAC2 e SAC3, os quais possuíam relação comprimento largura (L/B) crescente, respectivamente de 1,0, 4,0 e 7,3. Todos os SACs-EHSS foram preenchidos com brita # 0 e receberam esgoto sanitário (ES). Foram realizados ensaios com traçador em dois momentos, antes e após os SACs-EHSS receberem ES, buscando-se, com isso, avaliar as diferenças no comportamento hidrodinâmico dos sistemas, após a passagem de ES, bem como determinar o parâmetro número de dispersão d. No período compreendido entre as execuções dos ensaios com traçador, os sistemas foram monitorados por 90 dias, sendo avaliadas as variáveis pH, condutividade elétrica (CE), demanda química de oxigênio (DQO) e demanda bioquímica de oxigênio (DBO), ambas na fração bruta e solúvel no ES em tratamento em pontos afluente, efluente e intermediários. Os dados experimentais de CE, DQO e DBO foram avaliados na forma bruta, sem que fossem feitas correções quanto às perdas hídricas por evaporação, e também após essa correção, para que fosse avaliado o efeito dessas perdas nas variáveis. Para análise estatística, foi utilizada ANOVA a 5% de significância no caso em que os dados apresentavam distribuição paramétrica e Kruskal-Wallis a 5%, quando os dados eram não paramétricos. Os ensaios hidrodinâmicos mostraram comportamento disperso para os três SACs-EHSS, sendo os valores encontrados para d próximos entre si, indicando que as diferentes configurações não proporcionaram mudanças consideráveis nas condições hidrodinâmicas do sistema. Além disso, foi verificada redução dos valores de d do primeiro ensaio para o segundo. Não foram constatadas diferenças significativas quando comparadas as médias de eficiência de remoção entre os SACs para cada situação e nem entre os valores não corrigidos e corrigidos considerando-se as perdas por evaporação. Os dados experimentais de DQO e DBO nas formas bruta e solúvel foram ajustados ao modelo proposto por Brasil et al. (2007), explicitando-se, assim, os valores do parâmetro n das equações. Outros modelos cinéticos foram também ajustados aos dados de DQO e DBO na forma bruta e solúvel, corrigidos e não corrigidos, sendo observado que o modelo convencional de primeira ordem apresentou não só os menores valores para o coeficiente de decaimento de matéria orgânica k0, mas também os menores coeficientes de determinação (R²). Observou- se, em todos os casos, relação inversa entre os parâmetros d e n, sendo as maiores relações verificadas para n obtido a partir do ajuste aos dados de DBO, em todas as formas, e a menor correlação para os valores de n ajustados aos dados de DQO solúvel. Foi observada inexistência de associação entre os valores de n e TDH nos sistemas, havendo, no entanto, elevada correlação entre n e a taxa de decaimento da matéria orgânica obtida no trecho relativo ao primeiro quinto do comprimento dos SACs-EHSS, indicando que a variável se reduz, à medida que há aumento na degradação relativa do efluente. / This study aimed to evaluate the relation between the exponent parameter of hydraulic retention time (n), from the first-order kinetics mathematical model modified by Brazil et al. (2007), with hydraulic dispersion number (d) and also with the organic material’s degradability behavior along the length of the constructed wetlands of horizontal subsurface flow (CW-HSSF), given by the ratio COD /BOD. For this, non-planted CW-HSSF were used, with equal volumes, but with different geometric configurations, called CD1, CD2 and CD3, which had increasing relative length breadth (W/B) respectively by 1.0, 4.0 and 7.3. All CW-HSSF were filled with gravel # 0 and received sewage (S). Dye tracer tests were performed in two stages, before and after CW-HSSF receive S, seeking to evaluate the differences in the systems’ hydrodynamic behavior, after S’s passage, as well as to determine the parameter dispersion number d. In the period between the tests with tracer, the system was monitored for 90 days and were evaluated the variables pH, electrical conductivity (EC), chemical oxygen demand (COD) and biochemical oxygen demand (BOD), both raw and soluble fractions in ES treatment in tributary, effluent and intermediates points. The experimental EC, COD and BOD data were evaluated in gross form, without corrections to be made on the water loss due to evaporation, and also after that correction, in order to evaluate the water deficit effect on variables. Other hydrodynamic tests showed scattered results for the three SACs-EHSS, and the values found for d were close among each other, indicating that the different settings did not provide substantial changes regarding to the hydrodynamic flow. Furthermore, a reduction behavior in d was identified from the first test values to the second ones. There were no significant differences when compared the mean removal efficiency among SACs for each situation, either between the uncorrected and corrected evaporation losses. Statistical analysis ANOVA was applied at 5% significance level in the case where data presented parametric distribution and Kruskal-Wallis at 5% when data were not parametric. COD and BOD experimental data, in both gross and soluble forms, were fitted to the model proposed by Brazil et al. (2007), returning thus the values of equations’ n parameter. Other kinetic models were also fitted to the COD and BOD data in gross and soluble form, corrected and uncorrected, and then it was observed that the first order conventional model did not only present the lowest values for the k organic matter removal coefficient, but also the smallest determination coefficient (R²). It was noticed from the correlation study between the parameters d and n, in all cases, an inverse correlation. The highest correlations observed for n were obtained from the BOD fit to the data in all forms and the lowest correlation to the values of n set to soluble COD data. An association failure was observed among the n and hydraulic detention time (HDT) values in the systems, however, there was a high correlation between n and the organic matter decay rate obtained for the first fifth of CW-HSSFs’ length, indicating that the variable is reduced while the effluent’s relative degradation goes on.
|
112 |
Ozônio no tratamento de águas residuárias de laticínios: otimização e cinética de degradação da matéria orgânica / Ozone in dairy wastewater treatment: optimization and kinetics of organic matter degratationCarvalho, Marta Cristina Silva 12 August 2015 (has links)
Submitted by Marco Antônio de Ramos Chagas (mchagas@ufv.br) on 2016-07-11T18:26:26Z
No. of bitstreams: 1
texto completo.pdf: 977929 bytes, checksum: d330bab17b2ce728f8de32e1b9f0ed3d (MD5) / Made available in DSpace on 2016-07-11T18:26:26Z (GMT). No. of bitstreams: 1
texto completo.pdf: 977929 bytes, checksum: d330bab17b2ce728f8de32e1b9f0ed3d (MD5)
Previous issue date: 2015-08-12 / Conselho Nacional de Desenvolvimento Científico e Tecnológico / As indústrias de laticínios geram um grande volume de efluentes com elevado potencial poluidor e o cumprimento da legislação sobre o lançamento destes efluentes é fundamental para a preservação dos recursos hídricos. Devido às dificuldades em se obter tratamentos eficientes na degradação das águas residuárias de laticínios, alternativas tecnológicas tem sido investigadas. Reagentes químicos com elevado poder de oxidação vêm sendo utilizados na remoção de compostos recalcitrantes presentes nos efluentes, estes tratamentos são denominados Processos Oxidativos Avançados (POAs), dentre eles a ozonização se destaca por apresentar um potencial de oxidação superior à maioria. Além disso, a eficiência da ozonização pode ser melhorada quando combinada com processos físicos (flotação), outros POAs ou com íons metálicos. Nesse contexto, objetivou-se com o presente estudo avaliar a eficiência da flotação/ozonização na degradação da matéria orgânica presente em efluente sintético de laticínios. Em um primeiro momento avaliou-se a otimização da flotação/ozonização para a remoção da demanda química de oxigênio (DQO) de efluente sintético simulando águas residuárias de laticínios, considerando-se diferentes concentrações do gás ozônio, de peróxido de hidrogênio (H 2 O 2 ) ou íon metálico manganês (Mn 2+ ) para o efluente em diferentes pHs. A otimização do tratamento foi realizada por meio de inferências estabelecidas utilizando-se análise de variância, gráfico de Pareto, gráfico de contorno e função desejabilidade. Verificou-se, com base nos perfis de desejabilidade, que o tratamento flotação/ozonização combinado com o H 2 O 2 pode remover praticamente toda a DQO do efluente sintético, caso se utilize concentrações de gás ozônio acima de 42,9 mg L -1 , combinadas com concentrações de H 2 O 2 superiores a 1071,5 mg L -1 , para pH superior a 9,0, no entanto, em meio ácido (pH < 5,0) a adição do O 3 pode ser dispensada quando utilizada uma concentração de H 2 O 2 superior a 1071,5 mg L -1 . Para o processo de flotação/ozonização catalisado pelo Mn 2+ , a otimização do tratamento foi obtida para a máxima concentração de ozônio (53,8 mg L -1 ), no efluente sintético com pH 3,6, independente da concentração de Mn 2+ adicionada. Após a determinação dos pontos ótimos, verificou-se no segundo experimento a cinética de degradação da matéria orgânica (DQO), com o ajustamento de modelos matemáticos e a obtenção dos seus respectivos parâmetros cinéticos. A cinética da degradação da DQO foi realizada para o processo de flotação/ozonização utilizando-se: [O 3 ] de 42 mg L -1 e pH de 3,6; 7,0 e 10,4 e para o processo de flotação/ozonização catalisado pelo Mn 2+ utilizando-se concentração de O 3 de 42 mg L -1 , [Mn 2 ] de 0,040 mg L -1 e pH 7,0, por um período de reação de 240 min. Foram testados quatro modelos baseados na cinética de reação de primeira ordem: escoamento pistonado, mistura completa, modelo assintótico (residual) e o modelo de Chan e Chu (2003). Independente do tratamento utilizado, os modelos que mais se ajustaram foram o modelo assintótico e de Chan e Chu (2003). Os melhores resultados para a cinética foram obtidos para o meio ácido, apresentando coeficientes cinéticos aparentes (k) de 0,2394 min -1 para o modelo assintótico e o coeficiente experimental relacionado à cinética reacional (1/ρ) de 0,4816 min -1 para o modelo de Chan e Chu (2003). Com o intuito de validar os resultados obtidos, aplicou-se o processo de flotação/ozonização em água residuária bruta real de laticínios, durante 20 min em meio ácido, com concentração de gás ozônio de 42 mg L -1 . Os resultados mostraram remoções de aproximadamente 97% de DQO e DBO, 12% de nitrogênio total (N T ) e 91% da turbidez, atendendo assim os padrões estabelecidos pelo CONAMA 430/2011, exceto o N T . Palavras-chave: Laticínios, tratamento de efluentes, tratamento físico- químico, cinética. / The dairy industry generates a large volume of effluents with high pollution potential and, hence, compliance with standards and regulation is fundamental for the preservation of water resources. Due to difficulties in obtaining effective degradation of these contaminants, treatment alternatives have been investigated and proposed. Chemical treatments with high oxidation power have been used in the removal of recalcitrant compounds present in these effluents. These treatments are called Advanced Oxidation Processes (AOPs) and ozone stands out for presenting higher oxidation potential than the majority. However, ozonation efficiency may be improved when combined with physical processes (flotation), other AOPs or with metal ions. In this context, the aim of the present study was to evaluate the efficiency of flotation/ozonation in the degradation of organic matter present in dairy effluent. At first the optimization of flotation/ozonation was evaluated for COD removal of synthetic dairy effluent considering different concentrations of ozone gas, hydrogen peroxide (H 2 O 2 ) or manganese metal ion (Mn 2+ ) at different pHs. The optimization of the treatment was carried out by inferences established using analysis of variance, Pareto chart, contour plot and desirability function. It was found, based on desirability profiles, the flotation/ozonation combined treatment with H 2 O 2 can remove virtually all COD of the synthetic effluent, if using gas ozone of concentrations up to 42.9 mg L -1 combined with H 2 O 2 concentrations greater than 1071.5 mg L -1 to pH above 9.0, however, in an acid medium (pH < 5.0) the addition of O 3 may be dispensed with when using a H 2 O 2 concentration in excess of 1071.5 mg L -1 . For the process of flotation/Ozonation catalyzed by Mn 2+ , a treatment optimization is obtained for maximum ozone concentration (53.8 mg L - ) the synthetic effluent at pH 3.6, regardless of the concentration of Mn 2+ added. After finding of the optimal point, the kinetics of organic matter degradation (COD) was determined by the adjustment of mathematical models and identification of the respective kinetic parameters. The kinetics of degradation COD was performed for the process of flotation/ozonation using if: 42 mg L -1 [O 3 ], pHs 3.6, 7.0 and 10.4, and for the process of flotation/ozonation catalyzed by Mn 2+ using if concentration in 42 mg L -1 [O 3 ] and 0.040 mg L -1 [Mn 2+ ] 1 the pH 7.0, during a 240 min reaction period. Four kinetic models were tested: plug-flow reactor, continuous stirred-tank reactor, asymptotic model and the model of Chan and Chu (2003). Regardless of the treatment used, the asymptotic model and Chan and Chu’s model gave better fits. The best kinetics results were obtained for acidic condition with kinetic coefficients (k) of 0.2394 min -1 for the asymptotic model and (1/ρ) of 0.4816 min -1 for the Chan and Chu’s model. In order to validate the results, flotation/ozonation tests were carried out with raw dairy wastewater from a full-scale plant for 20 min in an acidic medium with O 3 concentration of 42 mg L -1 . Results showed removals of 97% for COD and BOD, 12% for nitrogen, and 91.2% for turbidity, which concentrations were within the Brazilian compliance standards, except nitrogen. Keywords: dairy industry, wastewater treatment, physico-chemical treatment, kinetics
|
113 |
Desempenho e influência dos capins tifton 85 (Cynodon sp.) e Vetiver (Chrysopogon zizanioides) no tratamento de esgoto sanitário em sistemas alagados construídos / Performance and influence of Tifton 85 (Cynodon sp.) and vetiver (Chrysopogon zizanioides) grasses in the treatment of sanitary sewage in constructed wetlandsJesus, Fernanda Lamede Ferreira de 24 March 2016 (has links)
Submitted by Marco Antônio de Ramos Chagas (mchagas@ufv.br) on 2016-07-12T10:44:12Z
No. of bitstreams: 1
texto completo.pdf: 1615515 bytes, checksum: 9eebc016f15d949a905a93f68f2b6d3d (MD5) / Made available in DSpace on 2016-07-12T10:44:12Z (GMT). No. of bitstreams: 1
texto completo.pdf: 1615515 bytes, checksum: 9eebc016f15d949a905a93f68f2b6d3d (MD5)
Previous issue date: 2016-03-24 / Fundação de Amparo à Pesquisa do Estado de Minas Gerais / No presente trabalho, procurou-se avaliar o desempenho de uma espécie de raízes fasciculadas (capim-vetiver) e outra estolonífera (capim-tifton 85), quando cultivadas em sistemas alagados construídos de escoamento horizontal subsuperficial (SAC- EHSS), no tratamento do efluente primário de esgoto sanitário. Para avaliação da influência da presença e do sistema radicular das plantas, foram utilizados três leitos, um plantado com capim-tifton 85 (SAC-EHSST), outro com capim-vetiver (SAC- EHSSV), com 12,5 propágulos por m², sendo o terceiro mantido sem plantas. Os SACs-EHSS foram construídos em paralelo, com fundo concretado e laterais em alvenaria, cobertos com lona de 2 mm de espessura. Como substrato, foi utilizada a brita gnáissica # 0, de diâmetro D60 igual a 7,0 mm, Coeficiente de Uniformidade (D60 /D10) de 1,6 e volume de vazios de 48,4 %, preenchido até a altura de 0,25 m. Cada SACs-EHSS, de área superficial de 4 m² e volume molhado (volume do substrato de preenchimento dos SACs-EHSS em contato com o esgoto sanitário em tratamento) de 1 m³, foi alimentado com vazão na faixa de 0,53 a 0,80 m³ d^-1, correspondente à de uma taxa de carregamento orgânico (TCO) de, aproximadamente, 350 kg ha^-1 d^-1 de DBO. Essa vazão proporcionou um tempo de detenção hidráulica (TDH) teórico entre 0,6 e 0,9 dias. Para avaliar o desempenho dos sistemas, foram efetuadas dez amostragens da água residuária afluente e efluente de cada SAC, no decorrer do período experimental, medindo-se a condutividade elétrica (CE), turbidez e o pH e quantificando-se as concentrações de DBO, DQO, SST, N-total, P-total, K e Na. Os valores foram corrigidos considerando-se as perdas de água por evaporação/evapotranspiração nos SACs-EHSS. Para a quantificação da produtividade de matéria seca e dos teores de N-total, P-total, K e Na no tecido vegetal, foram efetuados seis cortes da biomassa aérea das espécies vegetais cultivadas nos SACs-EHSS. No final do período de monitoramento, foram feitas escavações no meio suporte, para medição da profundidade atingida pelas raízes das plantas no substrato de preenchimento dos SACs-EHSS, além de serem quantificadas a massa e o volume ocupado pelas raízes das plantas, bem como seus teores de N-total, P-total, K e Na. De modo geral, as espécies avaliadas se adaptaram bem ao cultivo em SACs-EHSS utilizados no tratamento de esgoto sanitário, considerando- se a TCO aplicada. No substrato, foi observado maior volume, massa e profundidade das raízes do capim-vetiver, dando indícios de sua melhor adaptação e adequação a esse SAC-EHSS, comparativamente ao cultivado com o capim-tifton 85. O capim-tifton 85 mostrou-se capaz de remover mais Na em sua biomassa aérea que o capim-vetiver (p > 0,05), no entanto, em função de sua maior produtividade, houve tendência de maior remoção de N, P e K pelo capim-vetiver. A estação climática da primavera proporcionou maior remoção de nutrientes/poluentes pelas espécies vegetais avaliadas. Os SACs-EHSS cultivados e o não cultivado se mostraram eficientes na remoção da turbidez, SST, DBO, DQO e N-total o, apresentando, no entanto, relativamente baixas remoções de P, K e Na do esgoto sanitário. A unidade não cultivada apresentou desempenho semelhante (p < 0,05) à obtida nos SACs- EHSS plantados, no que se refere à remoção de DQO, N-total e K, porém foi menos eficiente que o SAC-EHSSV na retenção de SST, DBO e turbidez. Os resultados obtidos no presente trabalho indicaram que o capim-vetiver, representante do grupo de espécies vegetais de sistema fasciculado, apresentou melhor desempenho na remoção de poluentes do esgoto sanitário que o capim-tifton 85, representante de espécies estoloníferas. Possivelmente, o maior volume e alcance, em termos de profundidade, das raízes fasciculadas é que explicam as maiores remoções obtidas no SAC-EHSSV. / This study aimed to evaluate the performance of a species of fasciculate roots (grass vetiver) and other stolon root system (grass tifton 85) when cultivated in constructed wetland of horizontal subsurface flow (CW-HSSF), in the treatment of primary effluent sanitary sewage. To evaluate the influence of the presence and root system of the plants three beds were used, a planted with Tifton 85 (CW-HSSFT), another with vetiver grass (CW-HSSFV), with 12.5 propagules per m² and the third kept without plants. The CWs were constructed in parallel with bottom and of concrete and sides of masonry, covered with 2 mm thick of plastic blanket. As substrate (of filling) of the CW-HSSFs was used gravel gneissic # 0 (diameter -D60 = 7.0 mm, coefficient of uniformity D60/D10 = 1.6 and void volume of 48.4%, which was a layer of 0.25 m thick. Each CW-HSSF, having surface area of 4 m² and wet volume (volume filling substrate CW-HSSF in contact with the sewage in treatment) of 1 m³ was fed with a flow rate in the range of 0.53 to 0.80 m³ d ^-1, corresponding to an organic loading rate (OLR) of, approximately, 350 kg ha^-1 d^-1 of BOD. This flow rate provided a theoretical hydraulic retention time (HRT) between 0.6 and 0.9 days. To evaluate the performance of systems were made ten samples of wastewater influent water and effluent from each CW-HSSF, during the experimental period, to measure the electrical conductivity, turbidity and pH and quantify the concentrations of BOD, COD, TSS, total N, total P, K and Na. The values were corrected considering water losses by evaporation/evapotranspiration in CWs-HSSF. It was also done six cuts in the biomass of plant species, for the quantification of dry matter productivity and contents of total N, P, K and Na in the plant tissue. At the end of the monitoring period, excavations were made in the substrate of the CWs-HSSF, for depth measurement achieved by plant roots, quantify the mass and volume occupied by the roots, and the N-total, total-P, K and Na content. In general, the assessed species have adapted well to cultivation in CW-HSSF used to treat sanitary sewage, considering the OLR applied. In the substrate, there was a higher volume, mass and depth of fasciculate roots of vetiver grass indicates the better adaptation and adequacy of this grass, compared to the grass tifton 85 in CW-HSSF. The Tifton 85 grass proved to be able to remove more Na in its above ground biomass that vetiver grass (p > 0.05), however, due to its higher productivity, a trend towards greater removal of N, P and K by vetiver grass. The spring weather station provided greater removal of nutrients/pollutants by plant species evaluated. Cultivated CW-HSSF and uncultivated were efficient in the removal of turbidity, TSS, BOD, COD, Total-N, presenting, however, relatively low removal of P, K and Na of the sanitary sewage. The unit uncultivated showed similar performance (p < 0,05) to the CWs-HSSF planted as regards the removal of COD, total-N, and K, but was less efficient than CW-HSSFV retention TSS, BOD and turbidity. The results obtained in this study indicated that the vetiver grass, representative group of fasciculated plant species system performed that have better performance in removing sewage polluting the Tifton 85, representative of stoloniferous species. Perhaps the greatest volume and range, in terms of depth, of fasciculate roots is that explain the largest removals observed by CW-HSSFV.
|
114 |
Remoção biológica de nitrogênio amoniacal de efluentes com alta salinidade / Biological removal of ammoniacal nitrogen from high salinity wastewaterQuartaroli, Larissa 28 April 2016 (has links)
Submitted by Marco Antônio de Ramos Chagas (mchagas@ufv.br) on 2016-08-05T10:29:44Z
No. of bitstreams: 1
texto completo.pdf: 1856205 bytes, checksum: 84c73dca46a2c32f26d826bb501fbd2b (MD5) / Made available in DSpace on 2016-08-05T10:29:44Z (GMT). No. of bitstreams: 1
texto completo.pdf: 1856205 bytes, checksum: 84c73dca46a2c32f26d826bb501fbd2b (MD5)
Previous issue date: 2016-04-28 / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / A presente tese teve como objetivo analisar os efeitos do sal na remoção de amônia e na diversidade da comunidade microbiana envolvida neste processo. O trabalho foi dividido em três etapas, descritas em três artigos técnico-científicos. O primeiro artigo abordou os efeitos da salinidade na remoção de amônia de águas de produção de petróleo, em reatores em batelada sequencial. Foram realizados ensaios de bancada com a construção de reatores biológicos com alimentação intermitente. Utilizou-se lodo e efluentes industriais provenientes de uma estação de tratamento de efluentes de um terminal de petróleo. Os experimentos mostraram que se pode alcançar uma remoção completa de amônia via nitrificação biológica a concentrações de sal de até 100 g NaCl L^-1. No entanto, a uma concentração de 125 g NaCl L^-1, os microrganismos nitrificantes foram inibidos e uma remoção muito baixa de amônia foi observada nessas condições. No segundo artigo avaliaram-se as mudanças do perfil da comunidade microbiana do lodo responsável pela remoção de amônia da água de formação de petróleo quando submetidas ao aumento gradual de sal (NaCl) na etapa anterior. Analisou-se amostras de lodo de dois reatores biológicos em batelada sequencial, que foram operados com adição semanal de 5 g L^-1 de NaCl, até a completa inibição do processo de remoção de amônia que ocorreu com uma concentração de 125 g L^-1. Durante o processo de aclimatação do lodo ao sal, as amostras foram coletadas e tiveram seu DNA extraído. Realizou-se o PCR-DGGE e o sequenciamento massivo do gene rRNA 16S para análise da diversidade microbiana. Os perfis de bandas do PCR-DGGE mostraram que ocorreu uma mudança na comunidade microbiana à medida que se aumentou a concentração de sal no reator. Observou-se uma redução da presença de bactérias e concomitantemente um aumento das populações de archaeas. Os dados do sequenciamento revelaram que a remoção de amônia no reator é realizada por diferentes vias, através de bactérias nitrificantes autotróficas (Nitrosococcus, Nitrosomonas, Nitrosovibrio, Nitrospira e Nitrococcus), Archaea oxidante de amônia (Candidatus nitrosoarchaeum), microrganismos ANAMMOX (Candidatus Brocardia, Candidatus Kuenenia e Candidatus Scalindua) e potenciais nitrificantes heterotróficos (Paracoccus spp., Pseudomonas spp., Bacillus spp., Marinobacter sp., e Alcaligenes spp.). O terceiro trabalho investigou os efeitos do aumento gradual da concentração de NaCl na eficiência de remoção de amônia e na estrutura e diversidade da comunidade microbiana do grânulo aeróbio. Para tal, dois reatores biológico em batelada sequencial foram operados visando a formação de lodo granular aeróbio. Os reatores foram alimentados com efluente sintético, o qual foi enriquecido com NaCl, cuja concentração foi aumentada 5 g L^-1 de NaCl por semana. A remoção de amônia se manteve eficiente até salinidade de 40 g L^-1, sendo observado um leve decréscimo da eficiência com o aumento da salinidade. Não houve acumulo de nitrito e nitrato no efluente tratado, a remoção de ambos aumentou com o acréscimo de NaCl. Tais resultados evidenciaram a ocorrência de nitrificação/desnitrificação simultânea. Com o aumento da concentração de sal nos reatores os grânulos diminuíram de tamanho até se desintegrarem. A granulação aeróbia foi desfavorecida em concentração de NaCl acima de 10 g L^-1. A abundância de bactéria e archaea aumentou com o acréscimo de NaCl. Diversos gêneros de microrganismos responsáveis pela remoção de nitrogênio foram identificados no sequenciamento, incluindo aqueles envolvidos nos processos de nitrificação e desnitrificação convencionais (Nitrosomonas, Nitrosovibrio, Nitrospira, Nitrobacter, Denitromonas, Paracoccus, Bacillus, Klebsiella, Pseudomonas, Nitratireductor, Achromobacter, Thiobacillus, Azoarcus, Thauera, Alcaligenes, Hyphomicrobium, Rhodopseudomonas e Micrococcus), os microrganismos ANAMMOX (Candidatus kuenenia) e os heterotróficos (Paracoccus sp., Bacillus sp., Pseudomonas sp., Acinetobacter sp., Alcaligenes sp. e Aeromonas sp.). / This thesis aimed to analyze the effects of salt removal of ammonia and the diversity of the microbial community involved in this process. The work was divided into three chapters presented with three technical-scientific articles. The first article discusses the effects of salinity on the removal of ammonia from produced water from oil and gas production in sequencial batch reactors. Lab-scale tests were carried out in three sequencing batch biological reactors. The wastewater and sludge used in study consisted of produced water from oil extraction collected at an industrial treatment plant from a Brazilian petroleum terminal. The experiments showed that complete of ammonia removal via biological nitrification was achieved at salt concentrations up to 100 g NaCl L^-1. However, at a concentration 125 g NaCl L^-1, the nitrifying microorganisms were inhibited and a very low ammonia removal was achieved under these conditions. In the second article it was evaluated the changes of the microbial community profile of sludge responsible for the ammonia removal from produced water when subjected to a gradual increase of salt (NaCl). The biological sludge samples from two sequential batch reactors which were operated with a weekly addition of 5 g L^-1 NaCl were analyzed, until the complete inhibition of the ammonia removal process, which occurred at a concentration of 125 g L^-1. During the sludge acclimation process, the samples were collected and had their DNA extracted. The PCR-DGGE and massive sequencing of 16S rRNA region were carried out for analysis of microbial diversity. The profiles bands of PCR-DGGE showed that there was a change in the microbial community as the increased salt concentration in the reactor. It was observed a reduction in the bacteria population while the population of archaeas had an increase. The data of the 16S rRNA gene sequencing revealed that the ammonia removal was performed in different routes. The main microorganisms observed were the conventional autotrophic nitrifying bacteria (Nitrosococcus, Nitrosomonas, Nitrosovibrio, Nitrospira, Nitrococcus), archaea oxidizing ammonia (Candidatus nitrosoarchaeum), ANAMMOX (Candidatus Brocardia, Candidatus Kuenenia, Candidatus Scalindua), and potential heterotrophic nitrifyers (Paracoccus spp., Pseudomonas spp., Bacillus spp., Marinobacter sp., Alcaligenes spp.). The third paper investigated the effects of gradual increase of NaCl concentration in the ammonia removal efficiency and the microbial structure and diversity of aerobic granular sludge. Two biological sequencing batch reactors were operated with aerobic granular sludge. The reactors were fed with a synthetic effluent enriched gradually with NaCl (5 g L^-1 of NaCl per week). The removal of ammonia remained effective within all salinities tested, but had a slight efficiency decline when salinity increased. There was no accumulation of nitrite and nitrate in the treated effluent. The nitrite and nitrate removal increased with the addition of NaCl. These results proved the occurrence of simultaneous nitrification/denitrification. As the salt concentration increased in the reactor, the aerobic granules size diminished until they completely disintegrated. The aerobic granulation was negatively affected in NaCl concentration above 10g L^-1. The abundance of bacteria and archaea increased with NaCl addition. Several genera of microorganisms responsible for removing ammonia were identified, including the conventional nitrification/denitrification (Nitrosomonas, Nitrosovibrio, Nitrospira, Nitrobacter, Denitromonas, Paracoccus, Bacillus, Klebsiella, Pseudomonas, Nitratireductor, Achromobacter, Thiobacillus, Azoarcus, Thauera, Alcaligenes, Hyphomicrobium, Rhodopseudomonas and Micrococcus), ANAMMOX (Candidatus kuenenia) and heterotrophic/aerobic nitrification denitrification microorganisms (Paracoccus sp., Bacillus sp., Pseudomonas sp., Acinetobacter sp., Alcaligenes sp. and Aeromonas sp.).
|
115 |
Aspergillus niger AN 400 como inóculo de reatores em batelada para remoção do corante vermelho do congo em meio aquoso sintético / Aspergillus niger AN 400 as inoculum of batch reactors for removal of the congo red dye in synthetic aqueous mediumWanderley, Carlos Ronald Pessoa 16 October 2007 (has links)
WANDERLEY, C. R. P. Aspergillus niger AN 400 como inóculo de reatores em batelada para remoção do corante vermelho do congo em meio aquoso sintético. 2007. 71 f. Dissertação (Mestrado em Engenharia Civil: Saneamento Ambiental) – Centro de Tecnologia, Universidade Federal do Ceará, Fortaleza, 2007. / Submitted by João silva (jpauloqxb@gmail.com) on 2016-04-22T19:23:42Z
No. of bitstreams: 1
2007_dis_crpwanderley.pdf: 1246158 bytes, checksum: 1e293305798372f53b2cb47f866ec9fd (MD5) / Approved for entry into archive by Marlene Sousa (mmarlene@ufc.br) on 2016-04-29T15:51:35Z (GMT) No. of bitstreams: 1
2007_dis_crpwanderley.pdf: 1246158 bytes, checksum: 1e293305798372f53b2cb47f866ec9fd (MD5) / Made available in DSpace on 2016-04-29T15:51:35Z (GMT). No. of bitstreams: 1
2007_dis_crpwanderley.pdf: 1246158 bytes, checksum: 1e293305798372f53b2cb47f866ec9fd (MD5)
Previous issue date: 2007-10-16 / The species Aspergillus niger AN 400 has been inoculated in batch in order to remove Congo Red dye from the synthetic environment and study the treatment efficiency in the presence and absence of glucose and the biomass immobilization effect on the process optimization. It has been applied 84 reactors, produced and held in a screw top container of glass, which had a useful capacity of 1,5 L, whilst the air was supplied by small compressors. The experiment lasted a period of 25 days and the reactors without support medium; 14 control reactors with dispersed fungal biomass on which was added glucose (1 g/L); 14 reactors with immobilized fungal biomass and 14 reactors with immobilized fungal biomass on which was added glucose (1 g/L). The results obtained demonstrated that the greatest efficiency in removing the dye occurred in the reactors containing immobilized biomass in a environment with glucose concentration (87%) or not (85%). The glucose considering the utilized concentration has not performed any influence on the process efficiency. The organic matter removal which was assigned to the likely presence of by products originated by the dye and compounds expelled in the environment by microorganisms. The immobilization of the biomass in the polyurethane foams was determinant to the process efficiency as fungus was in a biofilm shape, representing a mechanism against the toxic effect of the pollutant. / A espécie Aspergillus niger AN 400 foi inoculada em reatores em batelada com o objetivo de remover corante vermelho do congo de meio sintético e estudar a eficiência do tratamento na presença e ausência de glicose e o efeito da imobilização da biomassa sobre a otimização do processo. Foram utilizados 84 reatores, confeccionados em vidro e vedados com tampa rosqueável, e com volume útil de 1,5 L, sendo o ar fornecido por mini-compressores de ar. O experimento abrangeu período de 25 dias e os reatores foram agrupados de acordo com sua respectiva função em: 14 reatores de controle sem meio suporte; 14 reatores de controle com meio suporte; 14 reatores com biomassa fúngica dispersa; 14 reatores com biomassa fúngica dispersa e adição de 1 g/L de glicose; 14 reatores com biomassa imobilizada e 14 reatores com biomassa imobilizada e adição de 1 g/L de glicose. Os resultados obtidos mostraram que a maior eficiência de remoção do corante ocorreu nos reatores contendo biomassa imobilizada, com meio com glicose (87%) e meio sem glicose (85%). A glicose, na concentração utilizada, não influenciou na eficiência do processo. A remoção de matéria orgânica, em termos de DQO, não acompanhou a remoção do corante, o que foi atribuído à provável presença de subprodutos da degradação do corante e compostos excretados no meio pelos microrganismos. A imobilização da biomassa nas espumas de poliuretano foi determinante para a eficiência do processo, uma vez que os fungos estavam estabelecidos na forma de biofilme, representando um mecanismo contra o efeito tóxico do poluente.
|
116 |
Avaliação dos aspectos sanitários, agronomicos e de qualidade em melancias irrigadas com esgoto tratado / Avaliation of the sanitary, agronomics and final product quality aspects in watermelons irrigated with treated sewageCosta, Mayara Carantino 28 July 2006 (has links)
COSTA, M. C. Avaliação dos aspectos sanitários, agronomicos e de qualidade em melancias irrigadas com esgoto tratado. 2006. 112 f. Dissertação (Mestrado em Engenharia Civil: Saneamento Ambiental) – Centro de Tecnologia, Universidade Federal do Ceará, Fortaleza, 2006. / Submitted by Hohana Sanders (hohanasanders@hotmail.com) on 2016-04-28T14:36:40Z
No. of bitstreams: 1
2006_dis_mccosta.pdf: 6642585 bytes, checksum: 9160f6c72e1b7947abe8ff24ba59719a (MD5) / Approved for entry into archive by Marlene Sousa (mmarlene@ufc.br) on 2016-06-02T17:05:23Z (GMT) No. of bitstreams: 1
2006_dis_mccosta.pdf: 6642585 bytes, checksum: 9160f6c72e1b7947abe8ff24ba59719a (MD5) / Made available in DSpace on 2016-06-02T17:05:23Z (GMT). No. of bitstreams: 1
2006_dis_mccosta.pdf: 6642585 bytes, checksum: 9160f6c72e1b7947abe8ff24ba59719a (MD5)
Previous issue date: 2006-07-28 / The reuse of treated sewage on watermelon irrigation, variety Crimson Sweet, was investigated not only considering the sanitary aspects but also the productivity and final product quality. The experiment was conducted in the Research Centre on Wastewater Treatment and Reuse, owned by the Company of Water and Wastewater of Ceará, in Aquiraz-CE. The experimental delimitation was randomized blocks, with four repetitions and four treatments: raw water and soil fertilization (T1); treated wastewater and soil fertilization (T2); treated wastewater without external soil fertilization (T3); and treated wastewater and half of soil fertilization (T4). The irrigation waters used (raw water and effluent of a stabilization pond) were characterized by the physical-chemical and microbiological aspects. Both waters were in the limits normalized by the World Health Organization (WHO) for unrestricted irrigation. The irrigation methods drip and furrow were compared in verifying of which one is more suitable for effluent reuse on watermelon production. The productivity data indicated that there was no significative difference among the treatments on drip irrigation, where the biggest productivities were obtained on T1 and T2 treatments. For the furrow system, no satisfactory productivity was achieved. The study revealed a significative difference among the treatments regarding the physical-chemical characteristics of the fruits. However, the microbiological quality was never compromised. Sensorial tests revealed that only the treatment T2 (treated wastewater and soil fertilization) did not present a different flavour, significative on 5% level, compared to the treatment T1 (control), and that the irrigation systems drip and furrow could be indifferently used without compromising the product flavour. / Investigou-se o reúso de esgoto sanitário tratado na irrigação da cultura da melancia, variedade Crimson Sweet, tanto relacionado aos aspectos sanitários como também à produtividade e à qualidade do produto final. O estudo foi realizado no Centro de Pesquisa sobre Tratamento de Esgoto e Reúso de Águas da Companhia de Água e Esgoto do Ceará em Aquiraz-CE. O delineamento experimental foi em blocos ao acaso, com quatro repetições e quatro tratamentos: T1 - água do poço mais adubação; T2 - efluente mais adubação; T3 - efluente e T4 - efluente mais a metade da adubação. As águas de irrigação utilizadas (água de poço e efluente de lagoas de estabilização) foram caracterizadas sob os aspectos físico-químicos e microbiológicos, em que ambas estavam dentro dos limites estabelecidos pela OMS para irrigação irrestrita. Os métodos de irrigação por gotejamento e sulco foram comparados para a verificação do mais indicado para o reúso com efluentes na cultura da melancia. Por meio de análise dos dados de produtividade da cultura observou-se que não houve diferença significativa entre os tratamentos na irrigação por gotejamento, sendo que os melhores resultados foram obtidos nos tratamentos T1 e T2. Para o sistema de sulco, não foram obtidas produtividades satisfatórias. . O estudo indicou que houve diferença significativa entre os tratamentos em relação às características físico-químicas dos frutos produzidos, contudo, não houve comprometimento da qualidade microbiológica dos mesmos em nenhum dos tratamentos avaliados. Em relação às características sensoriais observou-se, que somente as amostras que receberam o tratamento T2 (irrigação com efluente mais adubação) não apresentaram sabor diferente, significativo ao nível de 5%, quando comparadas àquelas submetidas ao tratamento controle (T1), e que os sistemas de irrigação, sulco e gotejo, podem ser utilizados, indiferentemente, sem comprometer o sabor dos frutos produzidos
|
117 |
Imobilização do mediador redox riboflavina em fibra de celulose para degradação anaeróbica do azo corante amarelo ouro remazol RNL.Martins, Luide Rodrigo January 2012 (has links)
Programa de Pós-Graduação em Engenharia Ambiental. PROÁGUA, Pró-Reitoria de Pesquisa e Pós Graduação, Universidade Federal de Ouro Preto. / Submitted by Oliveira Flávia (flavia@sisbin.ufop.br) on 2014-12-05T15:50:54Z
No. of bitstreams: 1
DISSERTACAO_ImobilizaçãoMediadorRedox.pdf: 2025276 bytes, checksum: 269132a3379ce8331bff474c7a962747 (MD5) / Approved for entry into archive by Gracilene Carvalho (gracilene@sisbin.ufop.br) on 2014-12-09T21:00:07Z (GMT) No. of bitstreams: 1
DISSERTACAO_ImobilizaçãoMediadorRedox.pdf: 2025276 bytes, checksum: 269132a3379ce8331bff474c7a962747 (MD5) / Made available in DSpace on 2014-12-09T21:00:07Z (GMT). No. of bitstreams: 1
DISSERTACAO_ImobilizaçãoMediadorRedox.pdf: 2025276 bytes, checksum: 269132a3379ce8331bff474c7a962747 (MD5)
Previous issue date: 2012 / A literatura tem demonstrado a eficiência de algumas substâncias na melhoria da cinética de remoção de cor em águas residuárias contendo corantes do tipo azo. Entre essas substâncias está a riboflavina (vitamina B2) que é conhecida por atuar como mediador redox nas transferências de elétrons de uma fonte doadora para o azo corante. A riboflavina em sua forma livre é solúvel em meio aquoso e pode ser perdida no efluente final em um sistema de tratamento. A imobilização desta vitamina em um suporte insolúvel pode proporcionar a retenção e recuperação da mesma nos reatores e consequentemente viabilizar o seu reuso diminuindo os custos do processo. Neste trabalho realizou-se a síntese de um novo material (CM3) contendo riboflavina imobilizada na celulose via ligação covalente e investigou-se a sua influência na degradação anaeróbia do azo corante amarelo ouro remazol RNL. Os ensaios foram feitos em escala de bancada e regime de batelada por períodos de 48 horas e temperatura controlada (25°C). A primeira etapa do trabalho consistiu na modificação química da celulose. Este polímero foi mercerizado, succinilado e passou por reação com anidrido acético para em seguida reagir com a riboflavina e dar origem à CM3. Os efeitos da modificação foram analisados por técnicas de infravermelho e análise elementar. A concentração de riboflavina introduzida na celulose foi estimada em 71,3mg/g. A estabilidade deste material foi testada em diferentes condições de pH e mostrou-se estável entre os pH 2 e 9. A segunda etapa do trabalho teve como objetivo avaliar os efeitos da riboflavina imobilizada na degradação anaeróbia do azo corante amarelo ouro remazol RNL. Os experimentos realizados com lodo anaeróbio e CM3 mostraram uma taxa de remoção 1,56 vezes maior do que os ensaios feitos sem nenhum tipo de mediador redox, comprovando assim a efetividade deste material na melhoria da cinética de degradação anaeróbia do azo corante modelo. ______________________________________________________________________________________________ / ABSTRACT: Reports in the literature have demonstrated the effectiveness of some substances in improving the kinetics of color removal in wastewater containing azo dyes. Among these substances is riboflavin (vitamin B2), which is known to act as a redox mediator in the transfer of electrons from a donor source such as glucose to an azo dye. The use of riboflavin in its free form, which is soluble in aqueous medium, is not attractive from an economic point of view since it is lost in the effluent upon treatment. Immobilization of this vitamin onto an insoluble support may provide improvements such as retention and recovery in the same reactor and allowing its reuse thereby reducing the costs related to the process. The aim of this work was to synthesize a new material (CM3) containing riboflavin immobilized covalently onto cellulose and investigate its influence on the anaerobic degradation of a model azo dye (Remazol Gold Yellow RNL). The tests were performed in batch reactors and the temperature of the system was set at 25° C and maintained for 48 h. The first stage of the study was the chemical modification of cellulose. For this, the homopolymer was mercerized (NaOH 20%), modified with succinic anhydride, and then reacted with acetic anhydride in order to form internal carboxylic acid anhydride functions which were used to bind riboflavin to cellulose, yielding CM3. Chemical modification of cellulose was evaluated by techniques as IR with Fourier transform and elemental analysis. The concentration of riboflavin introduced into the cellulose was estimated an 71.3mg/gCM3 and chemical stability tests with CM3 showed it was stable between pH 2 and 9. The second stage of the study was to evaluate the effects of riboflavin immobilized on to cellulose (CM3) on the anaerobic degradation of azo dye, Remazol Gold Yellow (RNL). The experiments with anaerobic sludge and CM3 showed a removal rate 1.65 times greater than those tests carried out without any redox mediator, thereby evidencing the effectiveness of the immobilized catalyst.
|
118 |
Uso de wetland construído no tratamento de efluente de raniculturaBorges, Fernanda de Freitas [UNESP] 12 September 2014 (has links) (PDF)
Made available in DSpace on 2016-01-13T13:27:54Z (GMT). No. of bitstreams: 0
Previous issue date: 2014-09-12. Added 1 bitstream(s) on 2016-01-13T13:33:26Z : No. of bitstreams: 1
000855097.pdf: 1957590 bytes, checksum: a3fc1fc4b440aa9c308318be89885223 (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / O objetivo do trabalho foi avaliar o desempenho de um wetland construído no setor de ranicultura para o tratamento do efluente em duas fases da criação de rã-touro. Foram analisadas as variáveis limnológicas e a eficiência de remoção dos nutrientes, a retenção de nutrientes no sedimento e nas macrófitas utilizadas (Eichhornia crassipes, Typha domingensis e Cyperus giganteus), bem como o ganho de biomassa. O tratamento foi eficiente na remoção de nitrato, nitrito, turbidez, fósforo total, sólidos totais suspensos, demanda bioquímica de oxigênio, coliformes termotolerantes, sólidos totais dissolvidos e clorofila a. As maiores cargas de nutrientes foram encontradas na fase de maior quantidade de biomassa de rãs estocada, com menores remoções de fósforo. As macrófitas utilizadas apresentaram ganho de biomassa satisfatório, com concentrações de nutrientes superiores ao do sedimento. As três espécies estocaram mais nutrientes na fase de maior biomassa de animais, com maior carga de nutrientes. Eichhornia crassipes foi a espécie que mais armazenou nitrogênio e fósforo em ambas as fases e com maior ganho de biomassa na fase de maior biomassa de rãs. Das espécies emersas, T. domingensis foi a que apresentou maior ganho de biomassa em ambas as fases, estocando todos os nutrientes na fase de maior biomassa. Ocorreu tendência de diminuição da matéria orgânica do sedimento em ambas as fases da entrada para a saída do wetland em função da presença das macrófitas. Este mesmo padrão de redução foi observado em relação aos nutrientes do sedimento. Concluiu-se que o sistema de tratamento implantado foi eficiente na melhoria da qualidade do efluente, com redução de nutrientes e de coliformes termotolerantes. As macrófitas desempenharam papel importante na redução destes componentes e podem ser utilizadas para tratar efluentes da ranicultura / The aim of the work was to evaluate the performance of the constructed wetland in frog culture sector for the effluent treatment in two phases of bullfrog culture. Limnological variables and the removal efficiency of nutrients were analyzed, the nutrients retention in the sediment and macrophytes used (Typha domingensis, Cyperus giganteus e Eichhornia crassipes) as well as biomass gain of the same. The treatment was efficient in a nitrate, nitrite, turbidity, total phosphorus, total suspended solids, biochemical oxygen demand, thermotolerant coliforms total, total dissolved solids and chlorophyll a. The high nutrients loads found in the phase of the high biomass frog storage, with lower phosphorus removals. The macrophytes used presented biomass gain satisfactory, with nutrient concentrations above the sediment. The three species stocked more nutrients during the phase of the high biomass frog storage, which high nutrients load. Eichhornia crassipes was the specie that most stored nitrogen and phosphorus in both phases and greater biomass gain in the phase of the high biomass frog storage. From the emerged species, T. domingensis showed the higher biomass gain in both phases, stocking all nutrients in the phase of the high biomass frog storage. There was a tendency of reduction of the organic matter in the sediment in both phases of the inlet to the outlet of wetland due to the presence of macrophytes. This same pattern of reduction was observed relation to the sediment. It was concluded that the treatment system implanted was efficient in improving the quality of the effluent, reducing nutrient and fecal coliform. The macrophytes played an important role in the reduction of such components and may be used to treat effluents of the frog culture
|
119 |
Uso de reator aeróbio de leito fluidizado com circulação como dispositivo de pós-tratamento do efluente de um reator uasb compartimentado tratando esgotos sanitáriosTetila, Moacir Feba [UNESP] 08 June 2015 (has links) (PDF)
Made available in DSpace on 2016-02-05T18:29:45Z (GMT). No. of bitstreams: 0
Previous issue date: 2015-06-08. Added 1 bitstream(s) on 2016-02-05T18:33:46Z : No. of bitstreams: 1
000857634.pdf: 2687649 bytes, checksum: 921ce0c3510bd4902e13ea9e219c970f (MD5) / A pesquisa utilizou um Reator Aeróbio de Leito Fluidizado com Circulação (RALFC) como dispositivo de pós-tratamento do efluente de um Reator UASB Compartimentado (RUC) o qual tratou esgoto sanitário. O RUC foi constituído de 4 tubos de PVC, de diferentes diâmetros, dispostos de forma concêntrica e o RALFC por dois tubos de PVC, de diâmetros diferentes e concêntricos, e uma unidade de sedimentação na parte superior. A pesquisa foi dividida em partida e quatro fases distintas, denominadas fase 1A, 1B, 2A e 2B, nas quais foram variados os parâmetros de operação, como vazão de ar, vazão de efluentes, tempo de detenção hidráulica (TDH) e carga orgânica volumétrica (COV). De modo que durante a pesquisa foi constatado que a melhor fase de tratamento foi quando o RALFC operou com TDH de 4,7 horas e vazão de ar de 300 L/h. O sistema, nessa fase, apresentou um valor médio de DQO efluente de 55 mg/L, a partir de um valor bruto de 607 mg/L em média, gerando uma remoção total de 90%. Os parâmetros de controle como alcalinidade, pH, temperatura e ácidos orgânicos voláteis sempre estivaram dentro das recomendações da literatura, demonstrando uma baixa oscilação. Mesmo assim o sistema não apresentou bom desempenho na remoção de nutrientes, tendo em sua melhor fase de tratamento um efluente com 31 mg/L em média de nitrogênio total, a partir de um valor de entrada de 50 mg/L sendo que a maior parte desse nitrogênio foi removido durante a passagem pelo RUC. Por outro lado para o fósforo, os valores foram de 25 mg/L na entrada e no efluente 14 mg/L, do mesmo modo como ocorreu ao nitrogênio, a maior parte da remoção de fósforo foi realizada pelo RUC / The study used an aerobic fluidized bed reactor with circulation (RALFC) as the effluent post-treatment device of a UASB reactor Compartmented (RUC) which treated wastewater. The RUC was consisted of 4 PVC tubes of different diameters arranged concentrically and RALFC two PVC tubes of different diameters and concentric, and a sedimentation unit in the upper part. The research was divided into four distinct phases and starting, called Phase 1A, 1B, 2A and 2B, in which were various operating parameters such as air flow, flow of wastewater, hydraulic retention time (HRT) and volumetric organic load (VOC). So that during the research it was found that the best treatment phase was when the RALFC operated with HRT of 4.7 hours and air flow of 300 L / h. The system, at this stage, had an average effluent COD value of 55 mg/L, from the affluent valor of 607 mg/L on average, there by generating a complete removal of 90%. The control parameters as alkalinity, pH, temperature and volatile organic acids have always been within the recommended by the literature, demonstrating a low oscillation. Even so, the system hasn't showed good performance in the removal of nutrients, in their best treatment stage an effluent with 31 mg/L on average total nitrogen from an input value of 50 mg/L. The most part of nitrogen removal was during passage through the RUC. As for the phosphorus values were 25 mg/L in the effluent input and 14 mg/L, in the same as was the nitrogen, the majority of phosphorus removal was performed by RUC
|
120 |
Biossorção & biodegradação de azo corante: desenvolvimento de processos utilizando resíduos como fonte de microorganismos = Azo dye biosorption & biodegradation : process development with residues as source of microorganisms / Azo dye biosorption & biodegradation: process development with residues as source of microorganismsSantos, Graziely Cristina dos [UNESP] 20 October 2015 (has links) (PDF)
Made available in DSpace on 2016-02-05T18:30:04Z (GMT). No. of bitstreams: 0
Previous issue date: 2015-10-20. Added 1 bitstream(s) on 2016-02-05T18:32:57Z : No. of bitstreams: 1
000857420_20161020.pdf: 538495 bytes, checksum: 71f207f613d369a12335af37bd4d6be3 (MD5) Bitstreams deleted on 2016-10-21T11:52:41Z: 000857420_20161020.pdf,. Added 1 bitstream(s) on 2016-10-21T11:53:21Z : No. of bitstreams: 1
000857420.pdf: 2774155 bytes, checksum: cf7b15e266fb54c71a21eea29635dc2b (MD5) / Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES) / As indústrias têxteis estão entre aquelas que utilizam a maior parte da água em seus processos, além de diversos produtos químicos tais como corantes, detergentes, sais e mordentes. Assim, grandes volumes de efluentes são gerados. O tratamento de águas residuais, às vezes, não é satisfatória. Inúmeros estudos têm sido realizados para encontrar maneiras mais eficientes e de baixo custo para o tratamento de efluentes têxteis. Os tratamentos biológicos têm se mostrado eficazes, uma vez que alguns micro-organismos têm demonstrado sua capacidade de descoloração de efluentes. O presente estudo teve por objetivo avaliar o processo de descoloração do azo corante Direct Red 75 (DR75) 100 mg/L utilizando diferentes fontes de micro-organismos em diferentes sistemas de tratamento, a fim de encontrar uma alternativa eficaz e de baixo custo para o tratamento biológico de efluentes têxteis. Esta avaliação é apresentada em três capítulos brevemente descritos abaixo. O primeiro capítulo mostra a comparação entre dois micro-organismos. O fungo Phanerochaete chrysosporium e a levedura Saccharomyces cerevisiae (fermento biológico) foram os microorganismos utilizados no experimento do 1° capítulo, enquanto um consórcio de microorganismos obtido a partir do inóculo de um biodigestor de alimentos foi utilizado no segundo capítulo. Ambos os experimentos tiveram DR75 como única fonte de carbono e os resultados foram expressos em porcentagem de descoloração e absorbância relativa. A absorbância relativa, obtida pela razão entre a absorbância no comprimento de onda dos grupos cromóforo e azo, sugere a ocorrência de biodegradação pela variação das razões das amostras em comparação com o controle. Os resultados do capítulo 1 mostraram que o tratamento com S. cerevisiae foi mais eficiente que com P. chrysosporium, e a absorbância relativa sugere a ocorrência de biodegradação para ambos. Portanto, o DR75 foi mais... / The textile industries are among the ones which use the most water in their processes, in addition to many chemical products such as dyes, detergents, salts and mordant. Thus, great volumes of effluents are generated. Sometimes the wastewater treatment is not satisfactory. Numerous studies have been conducted to find more efficient and low-cost ways to treat textile wastewater. Biological treatments have been proven to be efficient, since some microorganisms have shown the ability to effluent decolorization. The present study aims to evaluate the decolorization process of the azo dye Direct Red 75 (DR75) 100 mg/L by different sources of microorganisms in different treatment systems in order to find an effective and low-cost alternative for the biological treatment of textile wastewater. The evaluation is presented in three chapters briefly described below. First chapter shows the comparison between two microorganisms. The fungus Phanerochaete chrysosporium and the fresh yeast Saccharomyces cerevisiae were the microorganisms used in the experiment of the first chapter, while a consortium of microorganisms obtained from an inoculum of food waste biodigester was used in the second chapter. Both experiments had DR75 as the only carbon source and results expressed as percentage of decolorization and absorbance ratio. Absorbance ratio, obtained by the ratio between the absorbance at a wavelength of the chromophore and azo groups, suggests the occurrence of biodegradation by varying the values of the samples compared to control. The results from chapter 1 showed that treatment with S. cerevisiae was more efficient, than P. chrysosporium and the absorbance ratio suggests the occurrence of biodegradation for both. Therefore, the DR75 was more easily biodegraded by fresh yeast that can be easily acquired, than by single strain of fungus, which seems to be an expensive and labored option for the treatment of textile wastewater. Analysis of ... / CAPES: 011821/2013-02
|
Page generated in 0.0562 seconds