• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 82
  • 13
  • 10
  • 1
  • Tagged with
  • 110
  • 57
  • 29
  • 27
  • 20
  • 19
  • 16
  • 16
  • 16
  • 16
  • 15
  • 15
  • 14
  • 14
  • 14
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Etude des systèmes polyélectrolytes / tensioactif en phase aqueuse et à l'interface liquide / gaz. Application à l'élaboration de micro - capsules

Onesippe, Cristel 15 December 2005 (has links) (PDF)
Par coacervation complexe, en choisissant le tensioactif approprié et en jouant sur le ratio molaire tensioactif/polymère, il est possible de faire précipiter un polymère à la surface de gouttelettes d'huile : le complexe insoluble polymère/tensioactif obtenu forme alors la membrane des micro-capsules dont le cœur hydrophobe peut contenir des molécules apolaires. Cette thèse est une étude de trois systèmes polymère/tensioactif de charge opposée pouvant constituer la paroi insoluble des micro-capsules. Le tensioactif anionique utilisé est le Sodium Dodecyl Sulfate (SDS) et les polymères choisis sont un chitosane, un chitosane modifié hydrophobe et une gélatine de type A. Les interactions physiques et hydrophobes (en absence de sel) entre ces différents polymères et le tensioactif sont caractérisées par micro-calorimétrie de titration, tensiométrie, conductimétrie, viscosimétrie, mesures de mobilités électrophorétiques et détermination des isothermes de complexation du SDS aux polymères.
12

Cellules électrochimiques produisant du gaz : suivi de l'électrolyse par émission acoustique et effets de la mouillabilité des électrodes sur le flux des charges électriques.

Brussieux, Charles 27 July 2011 (has links) (PDF)
Certains procédés d'électrolyse industriels, comme ceux de production de fluor et d'aluminium, génèrent du gaz sur des électrodes peu mouillées par l'électrolyte. Dans ces procédés, la convection est en grande partie induite par le mouvement des bulles. Le temps de résidence du gaz n'étant pas maitrisé, la modélisation de ces électrolyses se heurte à de nombreux défis. Ce travail propose un état des connaissances nécessaires à la modélisation de ce type de cellules. Après avoir mis au point une méthode permettant de réaliser des électrodes fortement hydrophobes, nous avons étudié le dégagement gazeux que celles-ci produisent. Nous avons observé que les bulles qui s'y forment croissent par coalescence et ce phénomène affecte la vitesse de croissance et la taille au détachement. Par la suite, nous avons démontré qu'en localisant le dépôt hydrophobe il est possible d'obtenir une population de bulles dont le nombre, la taille et la position sont maitrisés. Nous avons constaté que l'émission acoustique est un outil efficace pour mesurer, sans observation visuelle, la taille et la vitesse d'ascension des bulles produites par électrolyse. La fréquence la plus énergétique du spectre des salves d'émission acoustique des cellules d'électrolyse produisant du gaz permet, quand la fraction volumique de gaz est faible, de mesurer la taille de toutes les bulles dans la cellule. Quand les bulles sont nombreuses et denses, cette même fréquence est liée aux dimensions de la cellule, à la densité de courant, à la taille des bulles et à la fraction volumique en gaz dans le panache. Nous avons proposé une explication à cette observation basée sur l'hypothèse d'un couplage acoustique des bulles. En l'absence d'agitation vigoureuse, l'activité acoustique d'une cellule d'électrolyse produisant des bulles traduit l'importance du transport de matière aux électrodes. La mesure de la répartition de la densité de courant par la méthode des électrodes segmentées dans une cellule en convection libre a été réalisée. Cette étude a été menée dans le but de tester un outil de simulation numérique des cellules d'électrolyse produisant du gaz. L'effet de la mouillabilité de l'électrode sur la répartition du courant a été évalué.
13

Analyse du plomb par du papier carbone fonctionnalisé

Ossonon, Diby Benjamin 09 1900 (has links) (PDF)
Le plomb est un métal lourd bien connu pour sa toxicité pour l'homme et pour l'environnement, donc une méthode d'analyse précise et peu coûteuse est très souhaitable pour déterminer la teneur en plomb de divers spécimens. Ces dernières années, une attention particulière a été portée au développement de nouveaux capteurs électrochimiques pour quantifier les ions des métaux toxiques au niveau de trace. Le choix d'un matériau d'électrode et sa fonctionnalisation sont cruciaux pour le processus d'analyse. Le but principal de ce projet de recherche est de fonctionnaliser une électrode de papier carbone pour la détermination du plomb dans une solution aqueuse. À cet effet, le papier carbone activé, a été modifié avec de l'acide benzylphosphonique à partir de la réduction électrochimique des cations diazonium correspondants générés in-situ. La présence de la couche greffée a été confirmée et caractérisée par voltampérométrie cyclique, spectroscopie du photoélectron-X et par spectroscopie d'impédance électrochimique. Ainsi les groupements benzylphosphoniques, liés de manière covalente à la surface de l'électrode complexent les ions Pb2+ de la solution. La quantité de plomb complexée est déterminée par l'intégration de l'aire sous le pic d'oxydation ou de réduction d'un voltammogramme cyclique. Ces matériaux fonctionnels présentent une limite de détection de l'ordre de 0,034 µg.L-1 (S/N = 3) pour le plomb en solution. La détermination électrochimique du plomb a été examinée en variant différents paramètres tels que l'effet du pH de la solution d'immersion, l'effet du temps de préconcentration et aussi l'effet de la concentration du plomb en solution. ______________________________________________________________________________ MOTS-CLÉS DE L’AUTEUR : Électrochimie, diazonium, amine, phosphate, modification, carbone, métaux lourds, eau.
14

Nouvelles électrodes à oxygène pour SOFC à base de nickelates Ln2NiO4+δ (Ln = La, Pr) préparées par infiltration / New SOFC oxygen electrodes based on nickelates Ln2NiO4+δ (Ln = La, Pr) prepared by infiltration

Nicollet, Clement 13 May 2016 (has links)
L’amélioration des performances des piles à combustible à oxyde solide(SOFC) passe en partie par l’augmentation de l’activité électrocatalytique de l’électrode àoxygène. Cet objectif peut être atteint soit en recherchant des matériaux plus performants,soit en travaillant sur la mise en forme et la microstructure d’électrodes de matériaux connus.Cette thèse développe cette dernière approche en considérant surtout la technique originalede mise en forme par infiltration appliquée aux matériaux La2NiO4+δ et Pr2NiO4+δ, connuspour leurs propriétés de conduction mixte électronique et ionique. L’optimisation desparamètres a été effectuée sur des électrodes à base de La2NiO4+δ, et a conduit à lapréparation d’électrodes performantes. L’analyse approfondie des résultats de mesuresélectrochimiques a permis de démontrer l’importance primordiale des interfacesgaz/électrode (surface spécifique) et électrode/électrolyte sur l’efficacité de l’électrode.L’étude d’électrodes à base de Pr2NiO4+δ et des phases secondaires issues de sadécomposition ont mis en lumière les propriétés électrocatalytiques remarquables de l’oxydesimple Pr6O11, conduisant à des résistances de polarisation très faibles (Rp = 0,028 Ω·cm2 à600 °C). L’intégration de ce type d’électrode dans une cellule SOFC complète a permis demesurer une densité de puissance élevée de 825 mW·cm-2 à seulement 600 °C etremarquablement stable après 800 h de fonctionnement à 600 °C et 0,5 A·cm-2. / Increasing the electrocatalytic activity of the oxygen electrode is a possible wayto improve SOFCs performance. It can be achieved either by searching for new materials, orby working on the shaping technique and microstructure of electrodes prepared with wellknownmaterials.This thesis developed the latest approach by applying the infiltration technique to thenickelates materials La2NiO4+δ and Pr2NiO4+δ, known for their mixed electronic and ionicconduction properties. The benefits of the infiltration method over more usual techniquessuch as screen printing was first demonstrated on La2NiO4+δ electrodes. The thoroughanalysis of electrochemical measurements highlighted the extensive role of both thegas/electrode (specific area) and the electrode/electrolyte interfaces on the efficiency of theelectrode.The study of Pr2NiO4+δ-based electrodes, and especially of the secondary phases arisingfrom its decomposition, allowed discovering the remarkable electrocatalytic properties of thesimple oxide Pr6O11, leading to very low polarization resistance values (Rp = 0.028 Ω·cm2 at600 °C). The integration of such electrodes in SOFC single cells led to power densities up to825 mW·cm-2 at only 600 °C, with a remarkable stability measured during 800 h at 600 °Cand 0.5 A·cm-2.
15

Développement d'interfaces cerveau machine visant à compenser les déficits moteurs chez des patients tétraplégiques. Etudes expérimentales précliniques / Brain computer interface (BCI) for motor deficit compensation in motor disabled patients, with chronic cortical electrodes arrays. Experimental study in animals.

Costecalde, Thomas 12 December 2012 (has links)
Interface cerveau-machine pour compenser les déficits moteurs chez des patients ayant des troubles moteurs, avec des implantations chroniques d'électrodes corticales. Etude expérimentale sur animaux. Une interface cerveau-machine (ICM) est définie comme un système de communication qui permet à l'activité cérébrale seule de contrôler des effecteurs externes. L'objectif immédiat des ICM est de fournir des capacités de communication aux personnes gravement handicapées qui sont totalement paralysées par des troubles neuromusculaires, tels que la sclérose latérale amyotrophique, l'accident vasculaire cérébral ou une lésion de la moelle épinière. Des résultats prometteurs (des patients pilotent un joystick grâce à la modulation de leur activité corticale) permettre d'accroître l'espoir dans de futures applications d'ICM avec une matrice de microélectrodes implantées chroniquement à la surface du cortex. Des expériences récentes ont démontré la capacité d'un tétraplégique à contrôler un bras robotisé. Ce travail de thèse contribue aux études précliniques, réalisées en parallèle du développement technique afin de fournir la validation du protocole expérimental chez l'homme par étapes successives. Il permet de développer un dispositif d'enregistrement ElectroCorticoGramme (ECoG) chez des rats, pour l'implanter chez ces animaux et enregistrer leur activité ECoG lors d'expériences comportementales pour contrôler un effecteur externe. Deux types d'études en ligne ont été effectués: le contrôle du distributeur directement par l'activité corticale ou par la combinaison de la tâche motrice (appuyer sur la pédale) et la détection de la signature. Dans les études de contrôle direct par la détection, la Performance Générale (PG) de notre ICM a été de 21,01% ± 4,33 (10 animaux 69 expériences), mais le nombre d'appuis par minute est tombé à 0,57±0,47 rendant plus difficile l'interprétation de ces résultats. C'est pourquoi les expériences, plus complexes, nécessitant l'activation du levier et la détection de signature ont été réalisés. La PG, dans ce cas, est de 37,76% ± 9,64 avec un nombre d'appuis qui a augmenté à 3,24 ± 0,7. La comparaison avec une détection aléatoire nous a permis d'être sûr que ces résultats ne sont pas aléatoires (environ 25-30 fois plus que l'analyse aléatoire). L'une des caractéristiques la plus intéressante de ces expériences est que la zone qui semble en évidence concernée par l'exécution de la tâche motrice est la région du cervelet et non la zone motrice et sensori-motrice, zones qui étaient attendues, comme pour les humains. Un aspect de notre étude sur la neuroplasticité a été de démontrer que la signature, une fois identifiée sur le cervelet, peut être détectée en temps réel dans d'autres régions du cerveau. Nos résultats ont montré une PG de 15,16% ± 3,75 dans 97 expériences faites sur 8 rats. Ces résultats ont montré que l'activité cérébrale en corrélation avec la tâche comportementale, identifiée en premier lieu dans le cervelet, peut être détectée dans une zone différente du cerveau. La caractéristique principale de ce travail de thèse est la démonstration que l'activité neuronale enregistrée en continu au niveau d'une électrode corticale unique peut être efficacement utilisée pour piloter un effecteur avec un degré de liberté, au cours d'expériences longue durant jusqu'à une heure, avec un animal libre de ses mouvements capable de prendre des décisions de manière aléatoire sans indication. Ce travail est une étape déterminante, un premier pas, vers un programme plus vaste visant à fournir un certain niveau de mobilité pour des jeunes patients tétraplégiques. / Brain computer interface with chronic cortical electrode arrays for motor deficit compensation in motor disabled patients. Experimental study in rodents. A brain-computer interface (BCI) is currently defined as a hardware and software communication system that permits cerebral activity alone to control external devices. The immediate goal of BCI research is to provide communication capabilities to severely disabled people who are totally paralyzed or ‘locked in' by neuromuscular disorders, such as amyotrophic lateral sclerosis, brain stem stroke, or spinal cord injury. Promising results (patients piloting a joystick through modulation of their cortical activity) increase the hope of BCI with an array of microelectrodes chronically implanted at the cortex's surface, which doesn't exist yet. Recent experiments demonstrated the capacity for a tetraplegic to control a robotic arm. This PhD work contributes to preclinical studies, performed in parallel of technical development to provide validation of the human experimental protocol in successive steps. It contributes to develop ECoG recording device for rats, to implant them in the corresponding animals and record their ECoG activity during freely moving behavioural experiments to control an external effector. Two kinds of on-line studies have been done: the control of the dispenser directly by cortical activity or by the combination of motor task (push the lever) and detection of the signature. In studies of direct control by the detection the Overall Performance (OP) was 21,01%±4,33 (10 animals 69 experiments) but the number of push per minute fell to 0,57±0,47 making more difficult the interpretation of these results. That's why the experiments, more complicated, requiring both lever activation and signature detection have been realized. The OP, in this case, is 37,76%±9,64 with a number of push which increased back to 3,24±0,7. The comparison with random detection permitted us to be sure that these results are not random (around 25-30 fold more than random analysis). One of the most intriguing features of these experiments is that the area which seems prominently concerned by the execution of the motor task is the cerebellar area and not the central, motor and sensorimotor, areas which would be expected, as in human beings. An aspect of our neuroplasticity study has been to demonstrate that the signature, once identified on cerebellum, can be detected in real-time in other areas of the brain. Our results showed an OP of 15,16%±3,75 in 97 experiments done on 8 rats. These results showed that brain activities correlated with behavioural task identified firstly in cerebellum can be detected in a different area of the brain. The main feature of this report is the demonstration that neural activity continuously recorded at the level of one single cortical electrode can be efficiently used to pilot an effector with one degree of freedom, during experiments up to 1 hour, in a freely moving individual making decisions in a random unsupervised manner. This work is a determining first step towards a larger program aiming at providing a certain level of mobility to young cervical spinal-cord injured patients with tetraplegia.
16

Cellules électrochimiques produisant du gaz : suivi de l'électrolyse par émission acoustique et effets de la mouillabilité des électrodes sur le flux des charges électriques / Gas-producing electrolysis : acoustic emission monitoring and study of the impact of electrodes wettability on current distribution

Brussieux, Charles 27 July 2011 (has links)
Certains procédés d'électrolyse industriels, comme ceux de production de fluor et d'aluminium, génèrent du gaz sur des électrodes peu mouillées par l'électrolyte. Dans ces procédés, la convection est en grande partie induite par le mouvement des bulles. Le temps de résidence du gaz n'étant pas maitrisé, la modélisation de ces électrolyses se heurte à de nombreux défis. Ce travail propose un état des connaissances nécessaires à la modélisation de ce type de cellules. Après avoir mis au point une méthode permettant de réaliser des électrodes fortement hydrophobes, nous avons étudié le dégagement gazeux que celles-ci produisent. Nous avons observé que les bulles qui s'y forment croissent par coalescence et ce phénomène affecte la vitesse de croissance et la taille au détachement. Par la suite, nous avons démontré qu'en localisant le dépôt hydrophobe il est possible d'obtenir une population de bulles dont le nombre, la taille et la position sont maitrisés. Nous avons constaté que l'émission acoustique est un outil efficace pour mesurer, sans observation visuelle, la taille et la vitesse d'ascension des bulles produites par électrolyse. La fréquence la plus énergétique du spectre des salves d'émission acoustique des cellules d'électrolyse produisant du gaz permet, quand la fraction volumique de gaz est faible, de mesurer la taille de toutes les bulles dans la cellule. Quand les bulles sont nombreuses et denses, cette même fréquence est liée aux dimensions de la cellule, à la densité de courant, à la taille des bulles et à la fraction volumique en gaz dans le panache. Nous avons proposé une explication à cette observation basée sur l'hypothèse d'un couplage acoustique des bulles. En l'absence d'agitation vigoureuse, l'activité acoustique d'une cellule d'électrolyse produisant des bulles traduit l'importance du transport de matière aux électrodes. La mesure de la répartition de la densité de courant par la méthode des électrodes segmentées dans une cellule en convection libre a été réalisée. Cette étude a été menée dans le but de tester un outil de simulation numérique des cellules d'électrolyse produisant du gaz. L'effet de la mouillabilité de l'électrode sur la répartition du courant a été évalué. / Molten salts electrochemical processes, like fluorine and aluminium production processes produce bubbles on electrodes slightly wetted by an electrolyte. In those cells, the electrolyte convection is mainly induced by the motion of bubbles. Then, the residence time of gas is not under control and the modelling of such electrolysis still faces many challenges. This work begins with a collection of the information required to model gas-producing cells. We developed an electrochemical composite coating technique to achieve the production of highly hydrophobic electrodes. Then we studied the gas evolution obtained with these electrodes, we observed that coalescences determines the bubbles growth rate and sizes at detachment. When the hydrophobic deposit is local, it is possible to obtain a bubble population whose number, size and position are controlled. We found that the acoustic emission is an effective tool to measure the size and rising speed of bubbles produced by electrolysis without having to observe them visually. When the volume fraction of gas is low, the most energetic frequency of the spectrum of acoustic emission bursts allows measuring the size of all bubbles in the cell. When bubbles are numerous, the most energetic frequency of the acoustic emission spectrum is related to the dimensions of the cell, current density, sizes of the bubbles and gas volume fraction in the plume. We have proposed an explanation for this observation based on the assumption of an acoustic coupling of the bubbles. When bubbles are produced, the acoustic activity of an electrolysis cell is correlated with the mass transport at electrodes. We propose a set of measurements of the distribution of current density at the electrodes in a cell with electrolyte free convection. These measurements have been carried out to benchmark a numerical simulation tool. The effect of the wettability of the electrode on the current distribution was evaluated.
17

Aqueous dispersions of conducting polymers for opto-electronic applications / Dispersions aqueuses de polymères conducteurs pour les applications opto-électroniques

Hofmann, Anna 09 December 2016 (has links)
Dans ce travail, différentes solutions aqueuses de PEDOT: polyelectrolyte ont été synthétisées à partir de polymères anioniques de types polysaccharides et polystyrènes substitués par des groupements bis(sulfonylimide). Leurs morphologies, dopages,comportements rhéologiques ainsi que leurs propriétés opto-électroniques ont notammen tété caractérisés. Une étude systématique a révélé que les polyélectrolytes de masse molaire élevée portant un groupement fortement acide et ayant un squelette rigide permettent d'obtenir un dopage élevé, une dispersion efficace du PEDOT et donc des complexes PEDOT : polyelectrolyte plus conducteurs. L'utilisation du polyelectrolyte PSTFSI en tant qu'agent de complexation pour le PEDOT donne une dispersion stable montrant les caractéristiques d'un gel, ce qui facilite la fabrication de films minces par 'spin coating' ou doctor blade. Les films de PEDOT : PSTFSI ainsi obtenus montrent une transparence élevée et une conductivité de 330S.cm-1. Ces propriétés ont permis de les intégrer avec succès comme matériaux d'électrodes dans des dispositifs OLED, OPV et OECT. / In this work different aqueous dispersions of conducting poly(3,4-ethylenedioxythiophene) :polyelectrolyte (PEDOT:polyelectrolyte) complexes,made from anionic polysaccharides and from synthetic bis(sulfonylimide) substituted polystyrenes, have been synthesized and characterized regarding their doping, morphology, rheological behavior and opto-electronic properties. A systematic study revealed, that high molar mass polyelectrolytes with strongly acidic groups and a rigid backbone structure were favorable for a high doping and an efficient dispersion of PEDOT and allowed the development of highly conducting PEDOT:polyelectrolyte complexes. The use of the polyelectrolyte poly(4-styrenetrifluoromethane(bissulfonylimide)) (PSTFSI) as complexing agent for PEDOT resultedin stable dispersions with gel character, which allowed easy processing by spin coating and doctor blading. The obtained PEDOT:PSTFSI films were highly transparent,displayed a conductivity of up to 330S.cm-1 and were successfully integrated as electrodes in OLED, OPV and OECT devices.
18

MgH2-TiH2 hydrides as negative electrodesof Li-ion batteries / Les hydrures de MgH2-TiH2 en tant qu'électrodes négativesdes batteries Li-ion

Berti, Nicola 13 December 2017 (has links)
Les batteries lithium-ion sont aujourd’hui très utilisées pour alimenter l’électronique portable telle que les ordinateurs, les smartphones et les caméras. Cependant, de nouvelles applications telles que les véhicules électriques et les systèmes stationnaires de stockage d'énergie nécessitent des batteries à performances améliorées. En particulier, de nouveaux matériaux d'électrode avec des densités d'énergie plus élevées sont requis. Les hydrures de MgH2 et TiH2 et leurs mélanges possèdent de très fortes capacités électrochimiques (>1 Ah/g). Ils ont été étudiés comme matériaux d’électrode négative dans les batteries Li-ion. La réaction de conversion de ces hydrures avec du lithium et les changements structuraux induits ont été étudiés en détails pour mieux comprendre les mécanismes réactionnels et leur réversibilité. Les propriétés électrochimiques de couches minces de MgH2 et des poudres composites de MgH2+TiH2 ont été étudiées en utilisant à la fois des électrolytes organiques liquides et un électrolyte solide LiBH4. La capacité réversible et la tenue au cyclage dépendent fortement du rapport molaire entre les deux hydrures et des conditions de cyclage. Le transport de masse et la densité d’interfaces à l'intérieur de l'électrode sont identifiés comme les principaux facteurs affectant la réversibilité de la réaction de conversion / Today, lithium-ion batteries are widely used as power supplies in portable electronics such as laptops, smartphones and cameras. However, new applications such as full electric vehicles and energy storage stationary systems require enhanced battery performances. In particular, novel electrode materials with higher energy density are needed.MgH2 and TiH2 hydrides and mixtures of them have high electrochemical capacity (> 1 Ah/g). They have been studied as negative electrode materials in Li-ion batteries. The conversion reaction of lithium with these hydrides and the related microstructural changes have been deeply investigated to gain a better understanding of reaction mechanisms and their reversibility. The electrochemical properties of MgH2 thin films and MgH2+TiH2 composite powders have been evaluated using both liquid organic and solid (LiBH4) electrolytes. Reversible capacity and cycle-life are found to strongly depend on both molar ratio between the hydrides and cycling conditions. Mass transport and density of interfaces within the electrode are identified as the main factors affecting the reversibility of the conversion reaction
19

Réacteur d'électrosynthèse microstructuré : conception, étude et développement appliqués à l'oxydation du 4-méthylanisole / Electrochemical microreactor : design, study and development applied to 4-methylanisole oxidation

Attour, Anis 27 April 2007 (has links)
L’étude traite la réalisation et la validation d’un microréacteur destiné à l’électrosynthèse organique. Le système électrochimique modèle est l’oxydation du 4-méthylanisole en 4-méthoxy-benzaldéhyde-diméthylacétal. La simulation du comportement théorique d’un réacteur électrochimique travaillant à haute conversion pour l’oxydation du 4-méthylanisole a permis de déterminer les conditions pour lesquelles le réacteur apporte un meilleur rendement. Les essais expérimentaux effectués sur un microréacteur travaillant en continu et à haute conversion ont montré l’influence de la concentration de l’électrolyte support KF sur le rendement de la réaction. Pour un débit optimal de 0,2 ml min-1, une concentration initiale en réactif de 0,1 M et en appliquant un courant égal à 85% du courant théorique nécessaire à convertir totalement le réactif en une seule passe dans la cellule, la sélectivité atteint 86% (pour une conversion de 95%), alors qu’elle n’est que de 68% dans le procédé BASF. / This work concerns the realization and the validation of a microstructured reactor for organic electrosynthesis. The electrochemical reaction is the oxidation of 4-methylanisole to 4-methoxy-benzaldehyde-dimethylacetal. Theoretical behaviour simulations of high conversion thin-gap flow cell of the 4-methylanisole show conditions for which the reactor has best productivity. The experimental tests carried out on high conversion thin-gap flow reactor showed the influence of the supporting electrolyte (KF) concentration on the reaction yield. For an optimal flow rate of 0.2 ml min-1, an initial reagent concentration of 0.1 M and a current equal to 85% of the theoretical current necessary to convert all reagent, it is possible to reach selectivity of 86% with single pass high conversion (95%) , whereas selectivity on BASF process doesn’t exceed 68%.
20

Electrode 3D de PEDOT : PSS pour la détection de métabolites électrochimiquement actifs de Pseudomonas aeruginosa / PEDOT : PSS 3D electrodes for detection of Pseudomonas aeruginosa electroactive metabolites

Oziat, Julie 14 November 2016 (has links)
Lors d’infections, l'identification rapide des micro-organismes est cruciale pour améliorer la prise en charge du patient et mieux contrôler l'usage des antibiotiques. L’électrochimie présente plusieurs avantages pour les tests rapides : elle permet des analyses in situ, faciles et peu chères dans la plupart des liquides. Son utilisation pour l’identification bactérienne est récente et provient de la découverte de molécules donnant de forts signaux redox dans le surnageant de bactéries du genre Pseudomonas.Cette thèse s’intéresse à l’analyse de surnageants de la bactérie Pseudomonas aeruginosa, 4e cause de maladies nosocomiales en Europe. Tout d’abord, l’intérêt de l’analyse électrochimique de surnageants de culture dans une visée d’identification a été évalué. Pour cela, après l’étude de 4 potentiels biomarqueurs de la présence de cette bactérie en solutions modèles, l’analyse électrochimiques de surnageant de plusieurs souches P. aeruginosa a été effectuée. Les résultats obtenus sont prometteurs. Ils mettent en évidence une signature électrochimique complexe et souche-dépendante du surnageant.La suite de la thèse s’est intéressée à l’amplification de la détection électrochimique grâce à l’utilisation du polymère conducteur PEDOT:PSS. Il a été choisi pour ses bonnes propriétés électrochimiques, sa biocompatibilité et sa facilité de mise en forme. Il a tout d’abord été utilisé sous forme de films minces pour confirmer son pouvoir d’amplification. Une électrode 3D a ensuite été fabriquée par lyophilisation. L’utilisation de ce type d’électrode permet d’amplifier encore la détection en augmentant la surface d’échange mais aussi en confinant les bactéries dans l'électrode. / During infections, microorganisms fast identification is critical to improve patient treatment and to better manage antibiotics use. Electrochemistry exhibits several advantages for rapid diagnostic: it enables easy, cheap and in situ analysis in most liquids. Its use for bacterial identification is recent and comes from the discovery of molecules giving strong redox signals in the bacterial supernatant of the Pseudomonas genus.This thesis focuses on the supernatants analysis of the bacterium Pseudomonas aeruginosa. This bacteria is the fourth cause of nosocomial infections in Europe. First, the interest of supernatants electrochemical analysis for identification was evaluated. For this, after the study of four redox biomarkers of this bacterium in model solutions, supernatant electrochemical analysis of several strains of P. aeruginosa was performed. The results are promising. They highlight a complex strain-dependant electrochemical signature of the supernatant.Following, we focused in the amplification of the electrochemical detection through the use of the conductive polymer PEDOT: PSS. This polymer was chosen for its good electrochemical properties, its biocompatibility and its easy shaping. It was first used as a thin films to confirm its amplification power through biomarker adsorption. Then, a 3D electrode was made by freeze drying. The use of this type of electrode can further amplify the detection by increasing the exchange surface as well as confining the bacteria in the electrode.

Page generated in 0.4476 seconds