• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 85
  • 13
  • 10
  • Tagged with
  • 109
  • 34
  • 27
  • 22
  • 15
  • 14
  • 14
  • 13
  • 13
  • 13
  • 12
  • 12
  • 12
  • 11
  • 10
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
61

Etalonnage de caméras à champs disjoints et reconstruction 3D : Application à un robot mobile

Lébraly, Pierre 18 January 2012 (has links) (PDF)
Ces travaux s'inscrivent dans le cadre du projet VIPA " Véhicule Individuel Public Autonome ", au cours duquel le LASMEA et ses partenaires ont mis au point des véhicules capables de naviguer automatiquement, sans aucune infrastructure extérieure dédiée, dans des zones urbaines (parkings, zones piétonnes, aéroports). Il est doté de deux caméras, l'une à l'avant, et l'autre à l'arrière. Avant son déploiement, le véhicule doit tout d'abord être étalonné et conduit manuellement afin de reconstruire la carte d'amers visuels dans laquelle il naviguera ensuite automatiquement. Les travaux de cette thèse ont pour but de développer et de mettre en oeuvre des méthodes souples permettant d'étalonner cet ensemble de caméras dont les champs de vue sont totalement disjoints. Après une étape préalable d'étalonnage intrinsèque et un état de l'art sur les systèmes multi-caméra, nous développons et mettons en oeuvre différentes méthodes d'étalonnage extrinsèque (déterminant les poses relatives des caméras à champs de vue disjoints). La première méthode présentée utilise un miroir plan pour créer un champ de vision commun aux différentes caméras. La seconde approche consiste à manoeuvrer le véhicule pendant que chaque caméra observe une scène statique composée de cibles (dont la détection est sous-pixellique). Dans la troisième approche, nous montrons que l'étalonnage extrinsèque peut être obtenu simultanément à la reconstruction 3D (par exemple lors de la phase d'apprentissage), en utilisant des points d'intérêt comme amers visuels. Pour cela un algorithme d'ajustement de faisceaux multi-caméra a été développé avec une implémentation creuse. Enfin, nous terminons par un étalonnage déterminant l'orientation du système multi-caméra par rapport au véhicule.
62

Auto-calibration d'une multi-caméra omnidirectionnelle grand public fixée sur un casque / Self-calibration for consumer omnidirectional multi-camera mounted on a helmet

Nguyen, Thanh-Tin 19 December 2017 (has links)
Les caméras sphériques et 360 deviennent populaires et sont utilisées notamment pour la création de vidéos immersives et la génération de contenu pour la réalité virtuelle. Elles sont souvent composées de plusieurs caméras grand-angles/fisheyes pointant dans différentes directions et rigidement liées les unes aux autres. Cependant, il n'est pas si simple de les calibrer complètement car ces caméras grand public sont rolling shutter et peuvent être mal synchronisées. Cette thèse propose des méthodes permettant de calibrer ces multi-caméras à partir de vidéos sans utiliser de mire de calibration. On initialise d'abord un modèle de multi-caméra grâce à des hypothèses appropriées à un capteur omnidirectionnel sans direction privilégiée : les caméras ont les mêmes réglages (dont la fréquence et l'angle de champs de vue) et sont approximativement équiangulaires. Deuxièmement, sachant que le module de la vitesse angulaire est le même pour deux caméras au même instant, nous proposons de synchroniser les caméras à une image près à partir des vitesses angulaires estimées par structure-from-motion monoculaire. Troisièmement, les poses inter-caméras et les paramètres intrinsèques sont estimés par structure-from-motion et ajustement de faisceaux multi-caméras avec les approximations suivantes : la multi-caméra est centrale, global shutter ; et la synchronisation précédant est imposée.Enfin, nous proposons un ajustement de faisceaux final sans ces approximations, qui raffine notamment la synchronisation (à précision sous-trame), le coefficient de rolling shutter et les autres paramètres (intrinsèques, extrinsèques, 3D). On expérimente dans un contexte que nous pensons utile pour des applications comme les vidéos 360 et la modélisation 3D de scènes : plusieurs caméras grand public ou une caméra sphérique fixée(s) sur un casque et se déplaçant le long d'une trajectoire de quelques centaines de mètres à quelques kilomètres. / 360 degree and spherical multi-cameras built by fixing together several consumer cameras become popular and are convenient for recent applications like immersive videos, 3D modeling and virtual reality. This type of cameras allows to include the whole scene in a single view.When the goal of our applications is to merge monocular videos together into one cylinder video or to obtain 3D informations from environment,there are several basic steps that should be performed beforehand.Among these tasks, we consider the synchronization between cameras; the calibration of multi-camera system including intrinsic and extrinsic parameters (i.e. the relative poses between cameras); and the rolling shutter calibration. The goal of this thesis is to develop and apply user friendly method. Our approach does not require a calibration pattern. First, the multi-camera is initialized thanks to assumptions that are suitable to an omnidirectional camera without a privileged direction:the cameras have the same setting (frequency, image resolution, field-of-view) and are roughly equiangular.Second, a frame-accurate synchronization is estimated from instantaneous angular velocities of each camera provided by monocular Structure-from-Motion.Third, both inter-camera poses and intrinsic parameters are refined using multi-camera Structure-from-Motion and bundle adjustment.Last, we introduce a bundle adjustment that estimates not only the usual parameters but also a subframe-accurate synchronization and the rolling shutter. We experiment in a context that we believe useful for applications (3D modeling and 360 videos):several consumer cameras or a spherical camera mounted on a helmet and moving along trajectories of several hundreds of meters or kilometers.
63

Étalonnage du cinquième télescope de l'expérience H.E.S.S. et observation du Centre Galactique au delà de 30 GeV / Calibration of the fifth telescope of the H.E.S.S. experiment and observation of the Galactic Centre above 30 GeV

Chalmé-Calvet, Raphaël 23 November 2015 (has links)
La phase II de l’expérience H.E.S.S. (High Energy Stereoscopic System) est constituée de cinq télescopes à imagerie Cherenkov dédiés à l’observation de sources astrophysiques de l’hémisphère sud émettant des photons au-delà de 30 GeV. Cette thèse présente le fonctionnement de cet instrument ainsi que toute la chaîne d’analyse associée avec une attention particulière sur le cinquième télescope mis en opération en juillet 2012. Les méthodes d’étalonnage du système sont détaillées. Ensuite, une méthode d’analyse des données, basée sur un modèle semi-analytique de développement des gerbes électromagnétiques dans l’atmosphère, est expliquée. Une méthode de reconstruction du spectre en énergie des sources de photon gamma de haute énergie est présentée. Les méthodes de sélection des photons gamma parmi le bruit de fond de hadrons sont étudiées. En particulier, le développement d’une nouvelle variable de rejet du bruit de fond utilisant les données temporelles du cinquième télescope est exposé. Une étude systématique des performances de l’analyse ainsi que des coupures de sélection des photons gamma est effectuée dans le but d’atteindre le plus bas seuil en énergie possible en contrôlant la soustraction du bruit de fond. Le Centre Galactique a longuement été observé par H.E.S.S., qui a mis à jour une source ponctuelle très brillante à très haute énergie ainsi qu’une une émission diffuse le long du plan Galactique. Les observations du Centre Galactique par la phase II de H.E.S.S. au cours de l’année 2014 sont présentées. Une reconstruction spectrale de la source centrale est effectuée. / The phase II of the H.E.S.S. experiment (High Energy Stereoscopic System) consists of five imaging atmospheric Cherenkov telescopes to study the southern astrophysical sources above 30 GeV. This thesis present the detector as well as the analysis chain, with a deep look on the fifth telescope commissioned on July 2012. The calibration method are described in detail. Then, an analysis based on a semi-analytical model of the electromagnetic shower development in the atmosphere is explained. A tool to reconstruct the energy spectrum of the very high energy gamma ray sources is presented. The methods of gamma ray selection among the hadron background are studied. Especially, the development of a new variable using the temporal data of the fifth telescope for the background rejection is shown. A systematic study of the analysis performances and of the selection cuts is accomplished, in order to reach the lowest energy threshold while keeping control of the background subtraction. The Galactic Centre has long been observed by H.E.S.S., which has detected a bright and punctual source at very-high energy as well as a diffuse emission along the Galactic plan. The Galactic Centre observations performed by the phase II of H.E.S.S. during the year 2014 are presented. A spectral reconstruction of the central source is performed.
64

Apport de l'impression 3D pour la réalisation de familles de fantômes d'étalonnage dédiés à la personnalisation de la mesure en dosimétrie interne / 3D printing contribution to create a set of calibration phantoms dedicated to personalized measurements in internal dosimetry

Beaumont, Tiffany 21 September 2018 (has links)
Après l’incorporation de radionucléides dans l’organisme, l’imagerie quantitative en médecine nucléaire et l’anthroporadiométrie sont utilisés pour quantifier l’activité retenue. L’étalonnage de ces systèmes in vivo peut être amélioré afin de tenir en compte de la variabilité individuelle. En vue d’optimiser la mesure de l’activité retenue, des fantômes d’étalonnage innovants ont été réalisés par impression 3D. L’infographie 3D a été utilisée pour la conception, en parallèle avec un travail d’ingénierie permettant l’inclusion de radionucléides et l’adaptation aux besoins des utilisateurs. Un jeu de fantômes thyroïdiens adapté à l’âge a été développé et utilisé pour améliorer la mesure anthroporadiométrique thyroïdienne des enfants. À la suite d’une étude systématique, les coefficients d’étalonnage des installations de routine et de crise de l’IRSN ont été déterminés pour l’adulte et les enfants de 5, 10 et 15 ans. Un fantôme thyroïdien pathologique a été développé en plus du jeu de fantômes thyroïdiens dédié à la crise pour améliorer la mesure de fixation thyroïdienne en médecine nucléaire. Une étude multicentrique a été réalisée pour optimiser l’étalonnage afin de mieux personnaliser le traitement des pathologies bénignes de la thyroïde. Pour l’anthroporadiométrie pulmonaire, une famille de fantômes de poitrine a été développée pour améliorer la surveillance des travailleuses du nucléaire. Finalement, ce travail de recherche a permis de développer des fantômes adaptés aux besoins et de démontrer leur utilité pour la quantification de l’activité en dosimétrie interne. / Following the incorporation of radionuclides in the body, quantitative imaging in nuclear medicine and in vivo spectrometry measurements are used to quantify the retained activity. The calibration of these in vivo systems can be improved to take account of individual variability. To optimize the measurements of the activity retained, innovative calibration phantoms were created and manufactured by 3D printing. 3D computer graphics were used for the design, coupled with an engineering work allowing the inclusion of radionuclides and the fit to users’ needs. A set of age-specific thyroid phantoms has been developed and used to improve the thyroid in vivo measurement of children. Following a systematic study, the calibration coefficients for IRSN emergency and routine installations were determined for adults and 5, 10 and 15 year old children. A pathological thyroid phantom has been developed in addition to the set of thyroid phantoms dedicated to the emergency to improve the thyroid uptake measurement in nuclear medicine. A multicentre study was carried out to optimize the calibration so that treatment of thyroid benign diseases moves towards a better personalization. For lung in vivo measurement, a set of breast phantoms has been developed to improve the monitoring of female workers. Finally, this research work has allowed developing several phantoms adapted to the needs and their usefulness was proven for the quantification of the activity in internal dosimetry.
65

L'expérience MAJIS : développement d'un imageur spectral pour les lunes de Jupiter / The MAJIS experiment : development of a hyperspectral imager for the Galilean moons

Guiot, Pierre 28 October 2019 (has links)
La mission JUICE de l’ESA sera la troisième mission d’exploration entièrement dédiée au système de Jupiter, et la première à se concentrer sur les lunes Galiléennes glacées susceptibles d’abriter des océans d’eau liquide. Prévue pour un lancement en 2022 et une insertion en orbite jovienne fin 2029, la sonde emportera parmi ses 11 instruments le spectro-imageur MAJIS. Les données d’un tel instrument comprennent une image à haute résolution spatiale de la zone étudiée et un spectre pour chacun des pixels de cette image. Ce spectre, dans la gamme allant de 0.5 à 5.5 µm, permet d’obtenir des informations physico-chimiques sur le contenu du pixel concerné. Le laboratoire où j’ai effectué mon travail de thèse, l’IAS, s’est vu confier la responsabilité de la réalisation de MAJIS. Dans ce contexte, l’objectif de mon travail était de contribuer à la définition et à l’implémentation de l’étalonnage de l’instrument : j’ai pour cela dû comprendre d’abord ses objectifs scientifiques et les exigences instrumentales qui en découlent, et maîtriser les caractéristiques des sous-systèmes qui composent MAJIS. J’ai tout d’abord traité les données de l’imageur intégral de champ de SPHERE, un instrument du VLT, qui avait observé la lune Galiléenne volcanique Io en 2014. Bien que ce satellite soit un objectif mineur de la mission JUICE, j’ai dû me confronter au fonctionnement de l’instrument pour en réduire les données et le traitement des spectres a requis le développement d’un modèle photométrique d’observation de la surface que j’ai pu confronter à la réalité et à d’autres études. L’identification de nombreux biais systématiques dans ces données et la quantification de ses limites de détection spatiales et spectrales m’ont permis de souligner l’aspect critique de la phase d’étalonnage de MAJIS pour que ses données soient exploitables. Avant cette étape toutefois, la connaissance des sous-systèmes qui vont constituer l’instrument est elle aussi nécessaire car certains de leurs paramètres conditionneront le déroulement de cet étalonnage et ils ne pourront pas tous être mesurés à cette occasion. J’ai donc caractérisé, à l’aide des bancs optiques dédiés à l’IAS, le plan focal de l’instrument et surtout son détecteur CMOS infrarouge de type HgCdTe. J’ai pu mesurer ses caractéristiques les plus courantes, comme son courant d’obscurité, sa profondeur de puits, son efficacité quantique, son éventuelle persistance, son bruit de lecture et la linéarité de sa réponse. Dans le cas d’une mission vers Jupiter, un autre aspect des performances du détecteur doit être étudié en détail : sa résistance aux radiations, particulièrement intenses dans la magnétosphère jovienne. J’ai pu effectuer une série de tests sur des détecteurs témoins avec des sources d’électrons, de protons et de photons de hautes énergies, qui m’ont permis de montrer la très bonne résistance du plan focal aux dégâts permanents. Ces données ont aussi permis de caractériser expérimentalement le signal transient induit par un bombardement aux électrons, ce qui m’a permis de valider l’approche de filtrage de ce signal qui sera implémentée en vol. C’est enfin grâce aux résultats de ces trois approches et au développement d’un modèle photométrique complet de l’instrument et de son dispositif d’étalonnage, que j’ai pu discuter l’architecture de ce dernier et proposer des séquences de mesure pour la campagne d’étalonnage. J’ai donc travaillé avec les ingénieurs du laboratoire et des industriels pour réaliser ce dispositif d’étalonnage, sélectionner les sources de lumière qui permettront la mesure de la réponse spatiale, spectrale et radiométrique de l’instrument nécessaires à l’interprétation de ses données au cours de la mission. Au moment de la rédaction de ce manuscrit, le banc d’étalonnage était en cours d’assemblage et j’ai donc pu conclure ce travail par la confrontation de mon modèle aux résultats expérimentaux de validation de certaines voies optiques du dispositif d’étalonnage. / The ESA JUICE mission will only be the third mission fully dedicated to exploring the Jupiter system, and the first with a specific focus on the icy Galilean moons that may harbor oceans of liquid water. Planned for launch in 2022 for a Jovian orbit insertion in late 2029, the probe will carry MAJIS among its 11 instruments, an imaging spectrometer operating from the visible to medium infrared wavelengths. This type of instrument provides very comprehensive data of the observed surface or atmosphere/exosphere: its high spatial resolution capability provides geomorphological information, such as the presence of craters or faults that mark the age and activity of the terrain, while for each pixel a spectrum is acquired. This spectrum, ranging from 0.5 to 5.5 $mu$m, yields physical and chemical information on the region of interest, thus placed in its geomorphic context. The Institut d'Astrophysique Spatiale, my PhD host laboratory, has a legacy of development of such instruments, prominently OMEGA aboard the 2003 Mars Express probe, of which MAJIS is the latest and current project. In this context, my work’s aim was to contribute to the definition and implementation of the instrument’s calibration: to achieve that I first had to understand its scientific objectives and the resulting instrumental requirements, as well as mastering the characteristics of MAJIS subsystems. As part of that process, I analyzed recent data of Io acquired with SPHERE, an integral field spectrometer on the VLT, which possesses similarities with the expected data products of MAJIS. Though this satellite is a minor objective of the JUICE mission, I had to understand the instrument itself in order to reduce its data and the spectra analysis required the development of a photometric model of a surface observation which I confronted to the reality and to previous studies. The identification of many systematic biases in these data and the quantification of its spatial and spectral detection limits allowed me to highlight the critical aspect in the upcoming calibration phase of MAJIS in order to get interpretable in-flight data. To reach this goal the knowledge of the subsystems of the instrument is also necessary because their behavior will condition the calibration scenario and all their parameters will not be measured again on this occasion. I have therefore characterized, using dedicated optical benches, the focal plane of the instrument and especially its HgCdTe CMOS infrared detector. I was able to measure its most common characteristics, such as its dark current, full-well capacity, quantum efficiency, persistence and readout noise. The knowledge of QE and full-well depth was incorporated into an end-to-end radiometric model of MAJIS, which I fed with the spectral radiance of different scientific targets, including modeled ionian surface flows. In turn, this allowed me to select sources and optical solutions suitable for calibration. Due to the intense radiation levels in the Jovian magnetosphere, the detector’s resilience to radiations also needed to be studied. I was able to perform three test campaigns on control detectors with sources of electrons, protons and high energy photons, which allowed me to show the overall very good resilience of the focal plane to permanent damages and to validate the foreseen transient effects reduction algorithms. These three approaches required that I develop a complete photometric model of the instrument and of its calibration setup which I used to discuss its design and submit test sequences for the calibration campaign. I have worked with our laboratory engineers and industrials to design then build the calibration setup with the light sources that will allow measurement of the spatial, spectral and radiometric responses of the instrument, required to interpret its data during the mission.
66

Calibrations et stratégies de commandes tomographique pour les optiques adaptatives grand champ : validations expérimentales sur le banc HOMER

Parisot, Amelie 24 October 2012 (has links)
L'optique adaptative (OA) permet de corriger en temps réel les déformations du front d'onde induites par la turbulence atmosphérique. Cependant, cette technique aujourd'hui mature connaît une limitation fondamentale : l'anisoplanétisme. Pour y pallier, différents concepts d'OA grand champ ont été développés. La turbulence est alors mesurée dans plusieurs directions afin de l'estimer tomographiquement. Ces systèmes soulèvent des problématiques spécifiques, telles que leurs processus d'étalonnage et leur contrôle temps réel au moyen de lois de commande tomographiques. Mes travaux de recherche ont consisté à modifier et optimiser le banc OA grand champ de l'Onera pour ensuite y implanter et comparer différentes loi de commande tomographiques envisagées pour les futurs instruments. Pour cela, une caractérisation et une implantation de nouveaux composants ont été effectuées, et j'ai développé une procédure d'identification de paramètres système dans un objectif double: alignement du banc et optimisation de lois de commande. Quatre lois de commande, explorant la diversité des solutions proposées, sont ensuite étudiées, du simple reconstructeur moindre carré à la commande optimale linéaire quadratique gaussienne, en passant par des approches de type pseudo boucle ouverte ou miroir déformable virtuel. Pour chacune, une optimisation des facteurs de réglage est effectuée, et une performance en fonction du champ est établie, ce pour plusieurs valeurs de rapport signal à bruit. Les résultats expérimentaux sont mis en regard avec les résultats obtenus par simulation, et les lois de commande sont comparées ensuite en terme de performance, robustesse et simplicité de mise en œuvre. / Adaptive Optics (AO) provides a real-time correction of the atmospheric turbulence effects. This technique is now well mastered; nonetheless it is limited by the anisoplanatism effect. Wide Field AO concepts have been developed to overcome this limitation. Turbulence is probed in several directions in order to perform a tomographic reconstruction of the turbulent volume. These complex systems raise critical challenges such as tomographic control and calibrations.My PhD work is focused on implementation and comparison of different tomographic control schemes developed in the perspective of future systems, after an optimisation of the Onera wide field AO bench. Calibration and integration of new components have been performed, and I have developed a method to identify system parameters with a twofold goal: bench alignment and control laws optimisation. Four control schemes have been studied, exploring the proposed solutions, from the simplest least-square to the optimal linear quadratic gaussian solutions including virtual deformable mirror and pseudo open loop approaches. In each case, an optimisation of tuning factors is performed and low and high noise conditions are explored, for several different fields of views. Experimental results are compared to numerical ones and control laws are analyzed in term of performance, robustness and implementation simplicity.
67

Méthodes informées de factorisaton matricielle pour l'étalonnage de réseaux de capteurs mobiles et la cartographie de champs de pollution / Informed method of matrix factorization for calibration of mobile sensor networks and pollution fields mapping

Dorffer, Clément 13 December 2017 (has links)
Le mobile crowdsensing consiste à acquérir des données géolocalisées et datées d'une foule de capteurs mobiles (issus de ou connectés à des smartphones). Dans cette thèse, nous nous intéressons au traitement des données issues du mobile crowdsensing environnemental. En particulier, nous proposons de revisiter le problème d'étalonnage aveugle de capteurs comme un problème informé de factorisation matricielle à données manquantes, où les facteurs contiennent respectivement le modèle d'étalonnage fonction du phénomène physique observé (nous proposons des approches pour des modèles affines et non linéaires) et les paramètres d'étalonnage de chaque capteur. Par ailleurs, dans l'application de surveillance de la qualité de l'air que nous considérons, nous supposons avoir à notre disposition des mesures très précises mais distribuées de manière très parcimonieuse dans le temps et l'espace, que nous couplons aux multiples mesures issues de capteurs mobiles. Nos approches sont dites informées car (i) les facteurs matriciels sont structurés par la nature du problème, (ii) le phénomène observé peut être décomposé sous forme parcimonieuse dans un dictionnaire connu ou approché par un modèle physique/géostatistique, et (iii) nous connaissons la fonction d'étalonnage moyenne des capteurs à étalonner. Les approches proposées sont plus performantes que des méthodes basées sur la complétion de la matrice de données observées ou les techniques multi-sauts de la littérature, basées sur des régressions robustes. Enfin, le formalisme informé de factorisation matricielle nous permet aussi de reconstruire une carte fine du phénomène physique observé. / Mobile crowdsensing aims to acquire geolocated and timestamped data from a crowd of sensors (from or connected to smartphones). In this thesis, we focus on processing data from environmental mobile crowdsensing. In particular, we propose to revisit blind sensor calibration as an informed matrix factorization problem with missing entries, where factor matrices respectively contain the calibration model which is a function of the observed physical phenomenon (we focus on approaches for affine or nonlinear sensor responses) and the calibration parameters of each sensor. Moreover, in the considered air quality monitoring application, we assume to pocee- some precise measurements- which are sparsely distributed in space and time - that we melt with the multiple measurements from the mobile sensors. Our approaches are "informed" because (i) factor matrices are structured by the problem nature, (ii) the physical phenomenon can be decomposed using sparse decomposition with a known dictionary or can be approximated by a physical or a geostatistical model, and (iii) we know the mean calibration function of the sensors to be calibrated. The proposed approaches demonstrate better performances than the one based on the completion of the observed data matrix or the multi-hop calibration method from the literature, based on robust regression. Finally, the informed matrix factorization formalism also provides an accurate reconstruction of the observed physical field.
68

Mesure de distance absolue utilisant l'interférométrie à balayage de longueur d'onde étalonnée par un peigne de fréquences / Absolute distance measurement using frequency sweeping interferometry calibrated by frequency comb

Yu, Wenhui 10 April 2019 (has links)
Dans cette thèse, nous avons mis en oeuvre un système de mesure de distance absolue (Absolute Distance Measurement, ADM) de haute précision utilisant l'interférométrie à balayage de fréquence (Frequency Sweeping Interferometry, FSI). La technique FSI exige que la plage de réglage de fréquence du laser balayé soit mesurée avec une précision élevée, ce qui est difficile en raison de l'absence d'un moyen simple de mesurer la haute fréquence d'un laser en temps réel. Dans cette thèse, un peigne de fréquence a été utilisé comme règle de fréquence lumière pour mesurer la plage de réglage de la fréquence du laser à balayage. Un peigne de fréquence formé par un laser femtoseconde est constitué de millions de lignes de peigne régulièrement espacées, ce qui permet de le considérer comme une règle de fréquence de la lumière. La calibration de fréquence a été réalisée en filtrant le signal hétérodyne entre le laser à balayage et les lignes de peigne en utilisant un filtre passe-bande étroit. Cette approche nous permet de détecter le signal d'étalonnage lorsque la fréquence du laser à balayage est proche d'une ligne en peigne. Etant donné que l’intervalle de fréquence entre les lignes de peigne peut être mesuré avec précision ou activement verrouillé en phase par rapport à un oscillateur radiofréquence (RF) stable, la plage d ’ accord du laser à balayage peut être mesurée avec une grande précision. En particulier, chacun des deux pics d’étalonnage peut être utilisé dans le calcul de la distance, ce que nous appelons des «sous-mesures» en un seul balayage. Combinée au grand nombre de lignes de peigne, la moyenne des sous-mesures améliore considérablement la précision des mesures sans balayage multiple. Dans la thèse, la condition de détection et les caractéristiques du signal hétérodyne entre le laser à balayage et la ligne de peigne sont présentées. Une conception de filtre pour filtrer le signal hétérodyne est réalisée. Un travail de modélisation concernant l'effet du bruit de phase des lasers sur la distorsion d'enveloppe du pic d'étalonnage a été présenté. Des travaux expérimentaux basés sur les concepts de mesure ont été réalisés. Il montre que l'utilisation du schéma de mesure proposé peut considérablement améliorer la précision de la mesure de distance. Dans l’une des mesures, une précision de 30 nm pour une distance d’environ 0,8 m, correspondant à une incertitude relative de 37 ppm (part-perbillion) a été obtenue. Le résultat a été obtenu sur la base d'une méthode de traitement du signal de comptage de franges. La grande précision a été obtenue grâce au grand nombre de sous-mesures et à la stabilité des lignes de peigne régulièrement espacées. Nous avons constaté que la mesure de vibration de la cible peut également être effectuée en prenant avantage des lignes de peigne denses. Une sensibilité élevée, limitée à 1,7 nm efficace en bruit, de la mesure des vibrations a été atteinte. Ce résultat nous permet de surveiller la vibration de la cible, ce qui est un problème important de la technique FSI. / In this thesis, we implemented a high-precision absolute distance measurement (ADM) system using frequency sweeping interferometry (FSI). The FSI technique requires the frequency tuning range of the swept laser to be measured with high accuracy and precision, which is challenging due to the lack of an easy way to measure the high frequency of a laser in real time. In this thesis, a frequency comb has been used as the light frequency ruler for measuring the frequency tuning range of the sweeping laser. A frequency comb formed by a femtosecond laser consists millions of evenly spaced comb lines so that can be regarded as a light frequency ruler. The frequency calibration was realized by filtering the heterodyne signal between the sweeping laser and the comb lines using a narrow bandpass filter. This approach allows us to detect the calibration signal when the frequency of the sweeping laser is in the vicinity of a comb line. As the frequency interval between the comb lines space can be precisely measured or actively phase-locked against a stable radio-frequency (RF) oscillator, the tuning range of the sweeping laser could be measured with high accuracy. Especially, each two calibration peaks can be used in the calculation of distance, which we call sub-measurements in a single sweeping. Combined with the large number of the comb lines, averaging of the sub-measurements improves greatly the measurement precision without multiple sweeping. In the thesis, the condition of detecting and the characteristics of the heterodyne signal between the sweeping laser and the comb line are presented. A filter design for filtering the heterodyne signal is performed. A modeling work concerning the effect of the phase noise of lasers on the envelope distortion of the calibration peak has been presented. Experimental works based on the measurement concepts have been carried out. It shows that using the proposed measurement scheme can greatly improve the distance measurement precision. In one of the measurements, a precision of 30 nm for a distance around 0.8 m, corresponding to 37 ppb (part-per-billion) relative uncertainty has been achieved. The result was obtained based on a fringe counting signal processing method. The high precision was obtained thanks to the large number of sub-measurements and the stability of the evenly spaced comb lines. We have found that vibration measurement of the target can be also performed taking the advantage of the dense comb lines. A high sensitivity, limited by 1.7 nm noise RMS, of vibration measurement has been achieved. This result allows us to monitor the vibration of the target, which is an important issue of FSI technique.
69

Étalonnage de l'algorithme d'étiquetage de la saveur par la mesure de sin (2b) dans LHCb

Poss, Stèphane 01 October 2009 (has links) (PDF)
L'objectif de la thèse est de proposer une procédure pour l'étalonnage de l'algorithme d'étiquetage de la saveur de l'expérience LHCb. Cet algorithme est fondamental pour de nombreuses mesures de paramètre de la violation de la symétrie CP. La mesure de référence est celle de sin(2b) car ce paramètre est très bien connu. Dans la première partie de ce document, nous présentons le cadre théorique du travail, avec une présentation de l'origine des observables de violation de la symétrie CP dans le Modèle Standard de la physique des particules. La deuxième partie présente le détecteur LHCb, avec une revue de ses sousdétecteurs. La troisième partie montre l'algorithme d'étiquetage de la saveur, avec une présentation des estimateurs choisis, ainsi que la procédure d'optimisation utilisée. Cette partie donne enfin les performances attendues. Le chapitre suivant présente l'étude de la sélection d'un canal de contrôle utilisé pour l'optimisation de l'algorithme. La cinquième partie présente la procédure d'extraction de la fraction de mauvais étiquetage depuis un autre canal de contrôle. Cette fraction de mauvais étiquetage est un paramètre fondamental de l'algorithme. Enfin, le dernier chapitre montre comment cette fraction de mauvais étiquetage est utilisée dans la mesure de sin(2b), et quels sont les conséquences d'une erreur sur cette fraction. On montre qu'avec une année de prise de données, la sensibilité à sin(2b) est suffisante pour contrôler l'algorithme. Mots clés : étalonnage, étiquetage de la saveur, LHCb, fraction de mauvqais étiquetage, violation de la symétrie CP, sin(2b), maximum de vraisemblance
70

Contributions à l'intégration vision robotique : calibrage, localisation et asservissement

Dornaika, Fadi 25 December 1995 (has links) (PDF)
Cette thèse concerne principalement l'intégration des fonctionnalités d'un système de vision avec celles d'un système robotique. Cette intégration apporte beaucoup d'avantages pour l'interaction d'un robot avec son environnement. Dans un premier temps, nous nous intéressons aux aspects de modélisation. Deux sujets liés à cette modélisation ont été traités : <br /> i) le calibrage caméra/pince et <br /> ii) la localisation caméra/objet. <br /> Pour le premier, nous proposons une méthode de calibrage non linéaire qui s'avère robuste en présence des erreurs de mesure ; pour le second, nous proposons une méthode linéaire très rapide et bien adaptée aux applications temps-réel puisqu'elle est basée sur des approximations successives par une projection para-perspective.<br /> Dans un deuxième temps, nous nous intéressons au contrôle visuel de robots. Nous adaptons la méthode "commande référencée capteur" à une caméra indépendante du robot asservi. De plus, dans le cas d'un positionnement relatif, nous montrons que le calcul de la position de référence ne dépend pas de l'estimation explicite des paramètres intrinsèques et extrinsèques de la caméra. Pour une tâche donnée, le problème de la commande peut alors se traduire sous la forme d'une régulation d'une erreur dans l'image. Nous montrons que la localisation temps-réel caméra/robot améliore le comportement dynamique de l'asservissement. Cette méthode de contrôle a été expérimentée dans la réalisation de tâches de saisie avec un robot manipulateur à six degrés de liberté. Toutes les méthodes proposées sont validées avec des mesures réelles et simulées.

Page generated in 0.2082 seconds