• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 174
  • 5
  • 1
  • 1
  • Tagged with
  • 182
  • 53
  • 47
  • 34
  • 30
  • 29
  • 26
  • 25
  • 24
  • 22
  • 22
  • 22
  • 20
  • 19
  • 17
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
181

Preparo e avaliação dos complexos de derivados de tiossemicarbazonas com(67/68 Ga) gálio, [99mTc] tecnécio e (111In)índio, como potenciais agentes para detecção de tumores / Preparation and evaluation of the thiosemicarbazone derivative complexes (67/68Ga)gallium, [99mTc]technetium and (111In)Indium as potential agents for tumor detection

Alyne Eloise Lafratta 06 June 2016 (has links)
Nas últimas décadas a medicina nuclear tornou-se uma grande aliada no auxílio ao diagnóstico de doenças e também para o tratamento do câncer. Parte deste sucesso está relacionada à constante pesquisa e desenvolvimento de novos radiofármacos. Uma classe de molécula que vem se mostrando promissora para o tratamento de tumores, tanto na sua forma orgânica quanto na forma de complexos organo-metálicos, é a tiossemicarbazona e seus derivados, os quais também podem formar complexos com radioisótopos metálicos dando origem a radiofármacos para diagnóstico e terapia. Neste trabalho foram preparados complexos com o ligante benzil-5-hidroxi-3-metil-5-fenil-4,5-diidro-1H-pirazol-1-carboditionato (H2bdtc) com os radioisótopos [99mTc]tecnécio, (67/68Ga)gálio e (111In)índio, e foram avaliados a pureza radioquímica, Log P e a estabilidade na presença de L-cisteína, L-histidina, soro albumina humana (SAH) e plasma de sangue humano; também foram avaliadas a taxa de captação dos radiofármacos in vitro em células de melanoma murino B16F10 e TM1M, além da avaliação da captação ex vivo e in vivo utilizando camundongos C57B/6 inoculados com as duas linhagens tumorais. Com o [99mT]tecnécio foram obtidos dois complexos diferentes, dependendo da concentração do PBS na solução, sendo que em um deles foi possível confirmar sua estrutura como [[99mTc]O(bdtc)(Hbdtc)] a partir do complexo de rênio [ReO(bdtc)(Hbdtc)], o outro complexo de [99mTc]tecnécio, bem como de (67/68Ga)gálio e (111In)índio não tiveram a estrutura caracterizada. A eficiência de marcação dos complexos foi superior a 90 %, com Log P maior que 1 para os complexos [[99mTc]O(bdtc)(Hbdtc)], [[99mTc]-bdtc] e [67/68Ga-bdtc] e 0,9 para [111In-bdtc]. Todos os complexos se mostraram com boa estabilidade na presença de L-cisteína e L-histidina, principalmente na primeira hora de incubação, mas não o foram na presença de SAH e plasma. A captação in vitro dos complexos em células B16F10 e TM1M variou entre 0,6 % e 1,8 %, e nos estudos de biodistribuição ex vivo foi obesrvada intensa e persistente captação hepática e no baço, superando 90 %, e captação no tumor variando de 0,2 % a 3 %, enquanto que nas imagens in vivo não foi possível observar de forma uma adequada captação nos tumores a ponto de permitir o uso como agente de diagnóstico. Os resultados permitem concluir que os complexos de derivados tiossemicarbazonas podem formar complexos com diferentes metais, mas novos derivados devem ser preparados para tentar melhorar o desempenho nos sistemas biológicos. Os experimentos com animais foram aprovados pela Comissão de Ética em Pesquisa da Faculdade de Medicina - USP, processo 372/12 / In recent decades, nuclear medicine has been used as diagnostic agent for disease and for the treatment of cancer. Part of this success is related to the constant research and development of new radiopharmaceuticals. Thiosemicarbazone and their derivatives have proven to be promising agent for the treatment of tumors, both in its organic form or as organo-metallic complexes. Also, they can to form complexes with metal radioisotopes giving radiopharmaceuticals for diagnosis and therapy. In this work we prepared complex of benzyl-5-hydroxy-3-methyl-5-phenyl-4,5-dihydro-1H-pyrazol-1-carboditionato (H2bdtc) with radioisotopes [99mTc]technetium (67/68Ga)gallium and (111In)indium and the radiochemical purity, Log P and stability in the presence of L-cysteine, L-histidine, human serum albumin (HSA) and human blood plasma were assessed; also were assessed the in vitro uptake rate of radiopharmaceuticals in murine melanoma cells B16F10 and TM1M, besides the evaluation of ex vivo uptake and in vivo using C57Bl/6 mice inoculated with both tumor lines. With [99mT] technetium two different complexes were obtained, depending on the concentration of the PBS in the solution, and one of them was had its structure to confirm as [[99mTc]O(bdtc)(Hbdtc)] from the standard rhenium complex [ReO(bdtc)(Hbdtc)], the other [99mTc] echnetium complex as well as (67/68Ga)gallium and (111In)indium not have characterized the structure. The labeling efficiency of compleos was higher than 90%, with log P higher than 1 for the complexes [[99mTc]O(bdtc)(Hbdtc)], [[99mTc]-bdtc] and [(67/68Ga)-bdtc] and 0.9 to [111In-bdtc]. All the complexes showed good stability in the presence of L-cysteine and L-histidine, especially in the first hour of incubation, but not in the presence of HSA and plasma. The uptake in vitro complexes in B16F10 and TM1M cells varied between 0.6% and 1.8%, and in ex vivo biodistribution studies was obesrvada intense and persistent liver uptake and spleen, exceeding 90%, and tumor uptake in changing from 0.2% to 3%, while in vivo imaging was not possible to observe a properly uptake in tumors, not allowing to use these molecules as a diagnostic agent. The results indicate that the thiosemicarbazone derivative complex can give complexes with different metals, but new derivatives should be prepared to try to improve performance in biological systems. The animal experimentation was approved by Comissão de Ética em Pesquisa da Faculdade de Medicina - USP, proccess 372/12
182

Efeito de interface nas propriedades ópticas de pontos quânticos de InP/GaAs / Interface effect on the optical properties of InP/GaAs quantum dots

Girardi, Tiago Illipronti, 1986- 21 August 2018 (has links)
Orientador: Fernando Iikawa / Dissertação (mestrado) - Universidade Estadual de Campinas, Instituto de Física Gleb Wataghin / Made available in DSpace on 2018-08-21T01:34:49Z (GMT). No. of bitstreams: 1 Girardi_TiagoIllipronti_M.pdf: 2091533 bytes, checksum: 1e5e58f3f5149c97c47c1bf44b7aa186 (MD5) Previous issue date: 2012 / Resumo: Neste trabalho, estudamos o efeito de diferentes condições de interface de InP/GaAs nas propriedades ópticas de pontos quânticos auto-organizados, crescidos por epitaxia de feixe químico, no modo Stranskii-Krastanov. Espera-se que os pontos quânticos de InP/GaAs apresentem alinhamento de bandas do tipo II, e somente os elétrons ficam confinados, enquanto os buracos ficam localizados nas camadas de GaAs em volta do ponto quântico, atraídos pelo elétron. No entanto, devido ao efeito de mistura de átomos nas interfaces o perfil de potencial nas interfaces pode ser alterado significativamente, afetando, com isso, as propriedades ópticas dos pontos quânticos. Foram estudadas amostras com as seguintes condições de interface entre a camada de InP e as camadas de GaAs: inclusão ou não de uma camada de InGaP em uma ou nas duas interfaces. O InGaP gera uma barreira para ambos os tipos de portadores de carga em uma junção tanto com o GaAs como InP e evita a difusa de As das camadas de GaAs para a de InP. Através de medidas de fotoluminescência resolvida no tempo, observamos a variação do tempo de decaimento da emissão óptica associada aos pontos quânticos de acordo com as diferentes condições de interface. Foi observado um tempo curto de decaimento em amostras sem a inclusão de InGaP e com a inclusão apenas na interface superior, enquanto foi observado um tempo longo quando incluímos camadas de InGaP em ambas as interfaces. O tempo de decaimento curto é incompatível com o alinhamento de bandas do tipo II, que deveria separar espacialmente o elétron do buraco. A partir desses resultados e estudos anteriores a esse trabalho, pudemos concluir que o tempo curto se deve à mistura de átomos nas regiões de ambas as interfaces, gerando ligas que localizam os portadores próximos um ao outro. O tempo longo na amostra contendo InGaP nas duas interfaces é atribuído à separação espacial do elétron e do buraco. O efeito de mistura de átomos nas interfaces, neste caso, não forma uma liga na interface que localize os dois tipos de portadores próximos um ao outro. Isso pode ser uma alternativa de preparação de pontos quânticos de InP/GaAs onde se mantém separados espacialmente o elétron e o buraco / Abstract: We studied the effect of different interface conditions on the optical properties of InP/GaAs self-assembled quantum dots grown by chemical beam epitaxy in the Stranskii-Krastanov mode. InP/GaAs quantum dots is expected to present type II band alignment, and only electrons are confined, whereas the holes are localized in the GaAs layers around the quantum dot, attracted by the electron. However, due to the atomic intermixing effect in the interface the potential profile can be strongly changed, affecting the optical properties of the quantum dots. We studied samples with the following conditions at the interfaces between the InP layer and GaAs layers: the inclusion, or the lack of, a InGaP layer at one of or both interfaces. InGaP generates a barrier for both types of carriers in a junction with GaAs and InP, and avoid the diffusion of As from the GaAs layers to the InP one. Using time-resolved photo-luminescence, we observed a change of the optical emission decay times associated to the quantum dots as the interface condition is changed. We observed a short decay lifetime in samples without InGaP layers and with the inclusion in the top interface only, whereas we observed a long decay time when we included InGaP layers in both interfaces. The short decay lifetime is incompatible with the type II band alignment, where the electron and the hole should be spatially separated. Using these and other previous results, we concluded that the short decay lifetime is due to the atomic intermixing in both interfaces regions, forming alloys that localize the carriers near each other. The long lifetime observed for sample containing InGaP in both interfaces is attributed to the large electron-hole spatial separation. In this case intermixing effects at the interfaces do not form a potential well to localize the carries near each other / Mestrado / Física / Mestre em Física

Page generated in 0.0398 seconds