• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 160
  • 18
  • 16
  • 16
  • 9
  • 4
  • 2
  • 2
  • 1
  • 1
  • 1
  • Tagged with
  • 293
  • 115
  • 109
  • 103
  • 69
  • 50
  • 48
  • 40
  • 36
  • 31
  • 28
  • 27
  • 26
  • 25
  • 24
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
291

Low Velocity Impact and RF Response of 3D Printed Heterogeneous Structures

Keerthi, Sandeep January 2017 (has links)
No description available.
292

Análisis de la respuesta frente al fuego de puentes mixtos multijácena

Alós Moya, José 21 December 2019 (has links)
Tesis por compendio / [ES] El diseño de puentes, a diferencia de lo que ocurre con el diseño de edificios o con el diseño de túneles ha dejado de lado la consideración de la acción del fuego hasta la fecha. Este vacío normativo, combinado con la gran repercusión económica y social de colapsos de puentes en el pasado como consecuencia de incendios, ha motivado un rápido incremento del número de estudios relativos a la ingeniería frente al fuego en el ámbito de los puentes. Aunque la acción del fuego no resulta del todo desconocida en el ámbito de las estructuras, sí que existen una serie de singularidades que impiden la trasposición directa de recomendaciones o de modelos de fuego simplificados ya desarrollados en otros campos que ya incorporan la acción del fuego en el diseño. En este contexto, el trabajo que a continuación se expone parte de un incendio ocurrido en el estado de Alabama en 2002, cuyas consecuencias fueron la demolición de un puente mixto de 37 metros de vano central, para plantear y validar una metodología que aborda el problema de forma numérica mediante tres modelos acoplados secuencialmente: modelo de incendios, modelo térmico y modelo mecánico Realizada una validación a nivel general se descubre que, aunque la configuración geométrica final obtenida se ajustan bastante a la realidad, la definición del incendio ha supuesto un gran número de hipótesis. Es por ello que se decide, en una segunda parte, realizar una campaña experimental que permita registrar la potencia del fuego, las temperaturas del gas y del acero y las flechas en un puente construido ad-hoc en el campus de la Universitat Politècnica de València. Este puente experimental tenía un vano único de 6 m de luz y fue sometido a cargas de fuego de hasta 1.3 MW. Mediante el empleo de los registros realizados en la campaña experimental se ha validado el modelo de incendio, el modelo térmico y el modelo mecánico. Con todo ello se ha puesto en evidencia la importancia del viento en la acción del fuego, la magnitud de los gradientes térmicos espaciales y la urgencia de desarrollar procedimientos simplificados que permitan la incorporación del fuego como acción en el ámbito de los puentes Las validaciones específicas de cada modelo han permitido además llegar a una serie de conclusiones de gran interés para la realización de futuras campañas experimentales en puentes a mayor escala. / [CA] El disseny de ponts, a diferència del que passa amb el disseny d'edificis o amb el disseny de túnels ha deixat de banda la consideració de l'acció del foc. Aquest buit normatiu, combinat amb la gran repercussió econòmica i social de col·lapses de ponts com a conseqüència d'incendis, ha motivat un ràpid increment del nombre d'estudis relatius a l'enginyeria del foc del foc en l'àmbit dels ponts. Encara que l'acció del foc no resulta del tot desconeguda en l'àmbit de les estructures, sí que hi ha una sèrie de singularitats que impedeixen la transposició directa de recomanacions o de models de foc simplificats ja desenvolupats en altres camps que ja incorporen l'acció del foc al disseny. En aquest context, el treball que a continuació s'exposa part d'un incendi ocorregut a l'estat d'Alabama en 2002 i que va provocar la demolició d'un pont mixt de 37 metres de va, per plantejar i validar una metodologia que aborda el problema de forma numèrica mitjançant tres models acoplats seqüencialment: model d'incendis, model tèrmic i model mecànic Realitzada una validació a nivell general es descobreix que, encara que la configuració geomètrica final obtinguda s'ajusta en gran mesura a la realitat, la definició de l'incendi ha suposat un gran nombre d'hipòtesis. És per això que es decideix, en una segona part, realitzar una campanya experimental que permeta registrar la potència del foc, les temperatures del gas i de l'acer i les fletxes en un pont construït ad hoc al campus de la Universitat Politècnica de València. Aquest pont experimental presenta un va únic de 6 m de llum i va ser sotmès a càrregues de foc de fins a 1.3 MW. Mitjançant l'ús dels registres realitzats a la campanya experimental s'ha validat el model d'incendi, el model tèrmic i el model mecànic. Amb tot això s'ha posat en evidència la importància del vent en l'acció del foc, la magnitud dels gradients tèrmics espacials i la urgència de desenvolupar procediments simplificats que permetin la incorporació del foc com a acció en l'àmbit dels ponts Les validacions específiques de cada model han permès a més arribar a una sèrie de conclusions de gran interès per a la realització de futures campanyes experimentals en ponts a major escala. / [EN] To date, the fire action has been left aside in the bridge design despite this action has been widely considered in other structures such as building and tunnels. This regulatory vacuum, combined with the great economic and social impact of bridge collapses in recent times as a result of fires, has led to a rapid increase in the number of studies related to fire engineering in the field of bridges. Although the action of fire is not entirely unknown in the field of structures, there are a number of singularities that prevent the direct transposition of recommendations or simplified fire models from such fields. In this context, the study started by using a real fire which occurred in the state of Alabama in 2002 and led to the demolition of the 37-meter main span of a composite concrete and steel bridge to introduce and validate a methodology that numerically addresses the problem by uncoupling the problem in three different models: fire model, thermal model and mechanical model. Once the validation was accomplished at a general level, it was discovered that, although the geometrical data were quite adjusted to reality, the definition of the fire had involved a large number of hypotheses. That is why carrying out an experimental campaign to record the power of the fire, the gas and steel temperatures and the vertical deflections of a bridge built ad-hoc on the campus of the Universitat Politècnica de València became a priority. This 6-meter single span experimental bridge was subjected to fire loads of up to 1.3 MW. Through the use of the information recorded during the experimental campaign, the fire model, the thermal model and the mechanical model were validated. Moreover, the importance of wind in the action of fire, the magnitude of spatial thermal gradients and the urgency of developing simplified procedures which allow the consideration of fire as an action in the field of bridges were also highlighted. Last but not least, the validation of the different models allowed the author to include useful guidelines in order to define future experimental campaigns with more powerful fires and longer span bridges. / Alós Moya, J. (2018). Análisis de la respuesta frente al fuego de puentes mixtos multijácena [Tesis doctoral]. Universitat Politècnica de València. https://doi.org/10.4995/Thesis/10251/116625 / Compendio
293

Experimental and numerical studies of masonry wall panels and timber frames of low-rise structures under seismic loadings in Indonesia

Susila, Gede Adi January 2014 (has links)
Indonesia is a developing country that suffers from earthquakes and windstorms and where at least 60% of houses are non-engineered structures, built by unskilled workers using masonry and timber. The non-engineered housing units developed in urban region are also vulnerable to seismic hazard due to the use of low quality of material and constructions method. Those structures are not resistant to extreme lateral loads or ground movement and their failure during an earthquake or storm can lead to significant loss of life. This thesis is concerned with the structural performance of Indonesian low-rise buildings made of masonry and timber under lateral seismic load. The research presented includes a survey of forms of building structure and experimental, analytical and numerical work to predict the behaviour of masonry wall and traditional timber frame buildings. Experimental testing of both masonry and timber have been carried out in Indonesia to establish the quality of materials and to provide material properties for numerical simulations. The experimental study found that the strength of Indonesia-Bali clay brick masonry are below the minimum standard required for masonry structures built in seismic regions, being at least 50% lower than the requirement specified in British Standard and Eurocode-6 (BS EN 1996-1-1:2005). In contrast, Indonesian timber materials meet the strength classes specified in British Standard/Eurocode- 5 (BS EN 338:2009) in the range of strength grade D35-40 and C35).Structural tests under monotonic and cyclic loading have been conducted on building components in Indonesia, to determine the load-displacement capacity of local hand-made masonry wall panels and timber frames in order to: (1) evaluate the performance of masonry and timber frame structure, (2) investigate the dynamic behaviour of both structures, (3) observe the effect of in-plane stiffness and ductility level, and (4) examine the anchoring joint at the base of timber frame that resists the overturning moment. From these tests, the structural ductility was found to be less than two which is below the requirement of the relevant guidelines from the Federal Emergency Management Agency, USA (FEMA-306). It was also observed that the lateral stiffness of masonry wall is much higher than the equivalent timber frame of the same height and length. The experimental value of stiffness of the masonry wall panel was found to be one-twelfth of the recommended values given in FEMA-356 and the Canadian Building code. The masonry wall provides relatively low displacement compared to the large displacement of the timber frame at the full capacity level of lateral load, with structural framing members of the latter remaining intact. The weak point of the timber frame is the mechanical joint and the capacity of slip joint governs the lateral load capacity of the whole frame. Detailed numerical models of the experimental specimens were setup in Abaqus using three-dimensional solid elements. Cohesive elements were used to simulate the mortar behaviour, exhibiting cracking and the associated physical separation of the elements. Appropriate contact definitions were used where relevant, especially for the timber frame joints. A range of available material plasticity models were reviewed: Drucker-Prager, Crystalline Plasticity, and Cohesive Damage model. It was found that the combination of Crystalline Plasticity model for the brick unit and timber, and the Cohesive Damage model for the mortar is capable of simulating the experimental load-displacement behaviour fairly accurately. The validated numerical models have been used to (1) predict the lateral load capacity, (2) determine the cracking load and patterns, (3) carry out a detailed parametric study by changing the geometric and material properties different to the experimental specimens. The numerical models were used to assess different strengthening measures such as using bamboo as reinforcement in the masonry walls for a complete single storey, and a two-storey houses including openings for doors and windows. The traditional footing of the timber structures was analysed using Abaqus and was found to be an excellent base isolation system which partly explains the survival of those structures in the past earthquakes. The experimental and numerical results have finally been used to develop a design guideline for new construction as well as recommendations for retrofitting of existing structures for improved performance under seismic lateral load.

Page generated in 0.0145 seconds