• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 49
  • 2
  • Tagged with
  • 51
  • 45
  • 44
  • 40
  • 17
  • 12
  • 10
  • 9
  • 9
  • 9
  • 8
  • 8
  • 7
  • 6
  • 6
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

Efeito da ciclagem térmica e imersão em clorexidina nas propriedades físicas das resinas de bisacrilato de metila e metacrilato de metila / Effect of thermo cycling and chlorexidine immersion in physicals properties of bis-acryl and methacryl resins

Fabiano Martins Malafaia 02 June 2009 (has links)
O uso de resinas acrílicas para confecção de restaurações provisórias é bastante difundido na prática odontológica. Dois tipos de resina encontram-se comercialmente disponíveis, as de bisacrilato de metila e as de metacrilato de metila e, em decorrência das exigências funcionais e estéticas das restaurações provisórias, estes materiais devem apresentar resistência, estabilidade de cor e durabilidade. Objetivo: Verificar a resistência à flexão, a microdureza, a rugosidade superficial e a estabilidade de cor de quatro resinas para restaurações temporárias quando submetidas à termociclagem e à imersão em clorexidina. Metodologia: Foram utilizadas as resinas Luxatemp e Structur 2, a base de bisacrilato de metila, e as resinas Duralay e Alike a base de metacrilato de metila. Os corpos-de-prova (n=220) foram divididos em quatro grupos, de acordo com a marca comercial e o ensaio realizado (resistência à flexão, microdureza, rugosidade superficial e estabilidade de cor), sendo avaliados em três tempos distintos: após 24 horas da confecção, após termociclagem (2000 ciclos) e após termociclagem e imersão em clorexidina a 0,12% por 14 dias. Resultados: Os dados obtidos foram analisados com o teste ANOVA e em seguida com o teste t (p<0,05), evidenciando que a termociclagem alterou as propriedades mecânicas das resinas, diminuindo a resistencia a flexão e a microdureza, aumentando a rugosidade superficial e ocasionando alteração de cor. A clorexidina não afetou as propriedades mecânicas das resinas estudadas, porém alterou a cor das resinas de metacrilato. Conclusões: As resinas de bisacrilato apresentaram resultados superiores aos das resinas de metacrilato para todas as variáveis estudadas. A termociclagem afetou negativamente todas as resinas, apenas as resinas de bisacrilato não apresentaram alteração de cor após imersão em clorexidina. / The use of acrylic resins is quite spread in dental practice, being accomplished temporary restorations with this material during the prosthetic treatment. Two chemical groups of this material exist, bis-acryl resins and another of methacrylate resins. Aim: This study verified the flexural resistance, micro hardness, superficial roughness and the color variation of four temporary resins submitted to thermo cycling and chlorexidine immersion. Methods: Luxatemp and Structur 2, bis-acryl based resins, and, Duralay and Alike, methacrylate based resins, has been used. The specimens (n=220) were divided in four groups, in agreement with the accomplished rehearsal, being appraised in three different times: after 24 hours, after the thermo cycling (2000 cycles) and after the thermo cycling followed by the immersion in 0.12% chlorexidine solution during 14 days. The tests were accomplished to the flexural, microhardness, superficial roughness and the color variation verification in all of the experimental times. Results: The results were statistically verified with ANOVA test followed by a t-test (p<0.05). Thermo cycling decreased flexural resistance and micro hardness, increased superficial roughness and caused color variation in all studied resins. Chlorexidine immersion did not changes physicals properties of studied resins, but caused color variation in methacrylate resins. Conclusions: The bis-acryl resins obtained results superiors to the checked for the methacrylate resins in all the experimental tests. Thermo cycling manegeament affected negatively all the studied resins. Only bis-acryl resins didnt presented color variation caused by chlorexidine immersion.
22

Influência da Formulação das tintas de base acrílica como barreira contra a penetração de agentes agressivos nos concretos. / Sem título em inglês.

Kai Loh Uemoto 18 August 1998 (has links)
Uma forma de reduzir a difusão de agentes agressivos para o interior do concreto é através da aplicação de sistemas de pintura, que funcionam como uma barreira ao ingresso destes agentes. A difusão dos agentes através de películas de pintura está relacionada com a sua porosidade, que, por sua vez, depende principalmente do teor e estrutura química da resina e do teor e morfologia dos pigmentos. Esta tese teve por objetivo principal demonstrar que, com uma formulação adequada, as tintas à base de resina acrílica podem ser utilizadas como barreira de proteção eficiente contra a penetração de água e vapor de água, anidrido carbônico (C\'O IND.2\') e íons cloreto, em estruturas de concreto ou em outros tipos de substratos. As formulações das tintas foram definidas em função do tipo de acabamento final e obtidas pela variação da relação pigmento/resina. Foram realizados ensaios de caracterização nas tintas líquidas e nas resinas utilizadas na preparação das tintas estudadas, bem como ensaios de desempenho nas películas livres e em concretos pintados, que apresentavam resistência à compressão de 20 e 40 Mpa. Para a medida da resistência à penetração dos agentes agressivos no concreto, foram desenvolvidos ensaios acelerados, com base em metodologias de avaliação de argamassas e concretos, adaptados a substratos pintados. A microestrutura das películas de tinta foi correlacionada com as propriedades físicas das películas e dos concretos pintados. Os resultados obtidos mostram a importância da formulação das tintas nos fenômenos de transporte e, além disso, mostram que tintas acrílicas e as estirenoacrílicas com diferentes temperaturas vítreas (Tg) apresentam comportamento físico distinto. Tintas de acabamento semi-brilho conferem boa proteção contra a penetração de agentes agressivos no concreto, enquanto que as de acabamento fosco apresentam função mais decorativa do que de proteção. / The diffusion of aggressive agents into concrete can be reduced by the application of painting systems which work as barriers to these agents. The capacity of these agents to pass through the paint is related to its porosity, which in turn is mainly dependent on the structure and content of the resin and on the morphology and content of the pigments. The main objective of this thesis is to demonstrate that with adequate formulation, paints based on acrylic resin polymers can be used as efficient barriers against the penetration of water and water vapour, carbon dioxide and chloride in concrete structures or any other porous substrate. Paint formulations were defined based on the final appearance (gloss) and obtained by varying the pigmentbinder ratio. Characterization tests on the liquid paints and polymers prepared for this study were done, as were performance tests on free dry films and painted concrete substrates, with compressive strength of 20 MPa and 40 MPa. In order to determine the effectiveness of paint in inhibiting the diffusion of aggressive agents into concrete, accelerated tests based on methodologies for the evaluation of mortars and concrete were developed. The films microstructures were correlated with their physical properties and with painted concrete. The results showed that the formulation of the paints has a important effect on the transport mechanism and also that acrylic and styrene-acrylic paints with different transition temperatures (Tg) do not present the same physical behavior. Glossy paints presented a high level of protection against the penetration of aggressive agents whereas matte finishes offered a more aesthetic function rather than protection.
23

Estabilidade dimensional da resina acrílica para coroas provisórias em função de diferentes tipos de processamento / Dimensional stability of acrylic resin for provisional crowns for different types of processing

David Alejandro García-López 27 April 2009 (has links)
A importância das restaurações provisórias no tratamento reabilitador oral é inquestionável. Os materiais utilizados para a elaboração deste tipo de restauração, também são de grande importância, tanto em função da técnica de manuseio como na qualidade e características dos mesmos, devido ao fato de que deles depende a longevidade, adaptação e qualidade das restaurações provisórias. O tipo de manipulação e a técnica utilizada influem nas propriedades físicas das resinas acrílicas, o que poderia causar falhas de adaptação. Por essas razões, o presente estudo teve por objetivo avaliar a estabilidade dimensional de uma resina acrílica (Dencor®), utilizada na confecção de coroas provisórias. Foram avaliados cinco tipos de processamento: I polimerização térmica utilizando líquido de polimerização rápida em mufla; II autopolimerização sob pressão em matriz de aço inox; III autopolimerização utilizando pincel; IV autopolimerização após mistura (pó + líquido) em pote dappen e inserção em matriz de aço inox na fase arenosa; V autopolimerização após mistura em pote dappen com inserção na matriz de aço inox na fase plástica. Para cada tipo de processamento foram confeccionados 10 corpos-de-prova. Foi avaliada sua estabilidade dimensional por meio de matrizes de aço inox confeccionadas seguindo a especificação da ADA No 19. Os corpos de prova foram armazenados em água destilada a uma temperatura de 37oC por 6 meses. Durante este tempo eles foram examinados com o microscópio óptico Mitutoyo com aumento de 20 vezes. Os resultados foram submetidos à análise de variância (Teste de Tukey) em nível de 5% de significância. Dos resultados obtidos, observamos que todos os corpos de prova tiveram as alterações dimensionais nos primeiros 7 dias da pesquisa independente da técnica utilizada. Já nos dias 30, 90, 180 não foi observada nenhuma alteração dimensional estatisticamente significante. / The importance of the provisional restorations in the oral rehabilitation treatment is undebated. The materials used for the fabrication of this type of restoration, are, as well, of great importance, as much as in function of the processing technique as in their quality and characteristics, due the fact that of them depend the longevity, adaptation and quality of the restorations. The mixing and processing technique influence the physical properties of acrylic resins, what could interfere with the adaptation of the provisional crowns. For these reasons, the present study aimed at evaluating the dimensional stability of an acrylic resin (Dencor®), used for fabrication of provisional crowns. Five types of processing techniques were evaluated: I thermal polymerization using fast polymerization liquid and flask; II - autopolimerization under pressure in stainless steel matrix; III - autopolimerization using bead brush technique to build the sample; IV - autopolimerization after mixture (powder + liquid) in dappen dish and insertion in stainless steel matrix at the sand phase; V - autopolimerization after mixture in dappen dish with insertion in the stainless steel matrix at the plastic phase. For each type of processing technique, 10 samples were made. Dimensional stability was evaluated by means of steel matrices made following the ADA specification no 19. The samples were stored in distilled water at a temperature of 37oC for 6 months. During this time they were examined with the optic microscope Mitutoyo with 20x magnification. The results were subjected to the analysis of variance (Test of Tukey) at the significance level of 5%. From the results obtained, it could be observed that all samples had dimensional alterations in the first 7 days independent of the technique used. In days 30, 90, 180 there were no statisticaly significant dimensional alteration.
24

Processamento de próteses totais: influência de 4 técnicas na alteração daposição dos dentes artificiais. / The processing of complete denture: influence of four techniques in artificial teeth movement.

William Barnabé 03 April 2000 (has links)
O processamento de resinas acrílicas utilizadas na confecção de bases de prótese envolve alterações dimensionais e distorções da base e movimentação dos dentes artificiais que podem levar à não utilização das próteses por desadaptação, dificuldade de engrenamento dos dentes e estética. Esse estudo avaliou a relação entre a movimentação dos dentes artificiais com os procedimentos de inclusão, prensagem e polimerização das bases de próteses totais. Foram utilizadas 64 amostras, divididas em quatro grupos de 16 (8 inferiores e 8 superiores) que receberam o seguinte tipo de inclusão, prensagem e processamento: a) grupo 1: neste grupo todas as amostras foram incluídas em muflas reforçadas de fibra de vidro, com muralha de silicona, prensagem por uma hora e polimerização em microondas, b) grupo 2: neste grupo todas as amostras foram incluídas em muflos metálicos, com muralha de silicona, prensagem por 12 horas e polimerização em banho de água, utilizando o ciclo de curta duração, c) grupo 3: neste grupo todas as amostras foram incluídas em muflas reforçadas de fibra de vidro, adaptadas para injetora de acrílico, com muralha de gesso pedra e polimerização em microondas, uma hora após a injeção do molde e d) grupo 4: neste grupo todas as amostras foram incluídas em muflos metálicos, com muralha de silicona, prensagem por uma hora e polimerização em banho de água, utilizando o ciclo de curta duração. Com os resultados obtidos podemos concluir que: a) todas as amostras sofreram contração após o processamento, b) a técnica com menor movimentação dos dentes artificiais foi a técnica 1, que apresentou diferença estatisticamente significativa em relação às demais c) quando comparados os arcos superiores e inferiores, independente da técnica e das medidas avaliadas, não se percebeu diferença estatisticamente significativa d) O tempo de prensagem, após a inclusão e antes da polimerização das próteses, interferiu na movimentação dos dentes artificiais e e) a medida que apresentou maior alteração foi a distância entre os molares, com diferença estatisticamente significativa com as demais. / The processing of acrylic resins used in the construction of complete denture bases involve dimensional alterations, distortion and artificial tooth movement which may prevent the prosthesis from being used due to discomfort, inadequate occlusion and esthetics. This study evaluated the relationship between artificial tooth movement, with the procedures of inclusion, compression and polymerization of complete dentures bases. The sixty-four samples utilized were divided into four groups of 16 (8 lower and 8 upper) which received the following type of inclusion, compression and processing: a) group 1: in this group all samples were included in resin-fiber reinforced flasks, with a silicone mould, compression for one hour and microwave polymerization; b) group 2: in this group all samples were included in metallic flasks, with a silicone mould, compression for 12 hours and thermopolymerization in water bath, using a short duration cycle; c) group 3: in this group all samples were included with gypsum stone mould using an acrylic injector to insert the resin inside the flasks, followed by microwave polymerization, one hour after mould injection and; d) group 4: in this group all samples were included in metallic flasks, with a silicone mould, compression for one hour and thermopolymerization in water bath, using short duration cycle. According to the results the following conclusions were drawn: a) contraction was observed in all samples after processing; b) group 1 presented statistically significant less artificial tooth movement, relative to the others; c) comparing the upper and lower arches, regardless of the technique and measurements evaluated, no statistically significant difference was found; d) the compression time following inclusion and before prostheses polymerization had a negative effect on artificial tooth movement and e) the biggest discrepancies were found in the distance between contralateral molars, with statistically significant difference to other measurements.
25

"Estudo das resinas acrílicas para bases de próteses totais com relação à resistência flexural, e à quantidade de monômero residual superficial" / Study of acrylic resin for complete denture considering flexural strength and quantity of superficial residual mono mer

Tarcisio José de Arruda Paes Junior 16 June 2005 (has links)
O objetivo deste trabalho foi o de avaliar a resistência à flexão e a quantidade de monômero residual superficial em resinas acrílicas para bases de próteses totais. Para tanto foram confeccionados corpos-de-prova nas dimensões de 2.5mm x 10mm x 65mm, utilizados em ambas as análises. Padronizou-se o processo de inclusão no qual foram empregadas muflas plásticas reforçadas por fibras de vidro. Sete grupos foram constituídos, de acordo com o tipo de processamento empregado na polimerização das resinas: Ac (Acron-MC) e Vw (Vipi-Wave) de ativação por energia de microondas; Lt (Lucitone 550 – grupo controle) e Vc (Vipi-Cril), resinas de ativação térmica convencional em banho de água aquecida no ciclo longo; Qc (QC-20), uma resina de ativação térmica em ciclo rápido e, dois grupos cuja resina era a mesma de ativação química (Vipi-Flash), processada em duas condições – à temperatura ambiente (Vf1) e, por aquecimento adicional em banho de água (Vf2). Os resultados mostraram diferenças estatisticamente significantes, onde o grupo Ac obteve as maiores médias para resistência flexural e os menores níveis de monômero liberado em relação às demais resinas. Os grupos Qc e Vf1 evidenciaram os piores resultados para ambos os testes, e a princípio, pareceu haver uma relação de causa e efeito entre, os elevados níveis de monômero residual encontrado nestes grupos, e a baixa resistência flexural observada. Verificou-se ainda que a imersão em água aquecida por 30min, da resina de ativação química, propiciou um ganho em qualidade do material para as características avaliadas. / The purpose of this work was the evaluation of flexural strength and quantity of superficial residual monomer in acrylic resin for complete denture. To perform both analyses it was developed specimens with a dimension of 2.5mm x 10mm x 65mm. The inclusion process was standardized by the use of plastic flasks reinforced with fiberglass. Seven groups were constituted in accordance with the type of resin polymerization process: Ac (Acron-MC) and Vw (Vipi-Wave) activated by microwave energy; Lt (Lucitone 550 – control group) and Vc (Vipi-Cril), conventional water bath curing cycles of heat activated acrylic resin; Qc (QC-20), fast cycle thermal activation; and two groups of self cured resin (Vipi-Flash), processed in two distinguished conditions: ambient temperature (Vf1) and additional heating in water bath (Vf2). The results have shown statistical significant differences. The Ac group had the highest mean to flexural resistance and the least level of released monomer in comparison with others resins. The Qc and Vf1 groups had the worst results for both tests. The initial conclusions showed a cause-effect relation between higher levels of residual monomer and lower flexural strength to this group. Additionally, it was verified that the immersion for 30 minutes of self cured resin in heated water gave an improvement of material quality to evaluated characteristics.
26

Avaliação da liberação de monômero residual, absorção de água e porosidade superficial em resinas acrílicas para prótese ocular / Evaluation of residual monomer, water sorption and porosity by acrylic resins used to eye prostheses

Oliveira, Rodrigo Elias de 07 March 2008 (has links)
A necessidade do aprimoramento das técnicas de confecção de próteses oculares que permitam satisfazer, com rapidez e excelência, a demanda de atendimento de pacientes portadores de perdas do bulbo ocular, levou ao desenvolvimento deste estudo comparativo no qual se avalia a porosidade superficial, absorção de água e liberação de monômero residual de resinas acrílicas. Foram estabelecidos quatro grupos de estudo, sendo cada grupo composto por 15 corpos de prova: Grupo 1 - resina acrílica termo polimerizável convencional / ciclo térmico convencional; Grupo 2 - resina acrílica termo polimerizável em microondas / ciclo microondas; Grupo 3 - resina acrílica termo polimerizável convencional / ciclo microondas; Grupo 4 - resina acrílica auto polimerizável com cadeia cruzada / auto polimerização. A avaliação da quantidade de monômero residual liberado foi realizada por meio de espectrofotometria, durante o período de 11 dias. A determinação da absorção de água baseou-se na diferença do peso apresentado pelos corpos de prova nas condições experimentais seco e após submersão em água deionizada por um período de 7 dias. A determinação da porosidade superficial foi calculada sob a forma de porcentagem por área de superfície analisada, empregando-se lupa estereoscópica para captação da imagem a ser processada pelo software ImageLab 2000®. Submetendo-se os dados à análise estatística ANOVA/TUKEY (p<=0,05) observou-se que a liberação de monômero residual foi significantemente maior no primeiro dia para o Grupo 1, semelhante durante todo o período para o Grupo 2, menor a partir do dia 8 para o Grupo 3 e decrescente até o dia 8 para o Grupo 4. A liberação de monômero residual foi semelhante para os Grupos 1 e 3, menor para o Grupo 2 e maior para o Grupo 4. A absorção de água foi semelhante para os quatro grupos de estudo. A maior porosidade ocorreu no Grupo 2, sendo os Grupos 1 e 3 semelhantes entre si. Concluiu-se que os ciclos térmicos de polimerização em água e em microondas não interferiram na liberação de monômero residual da resina acrílica termo polimerizável convencional. A liberação de monômero residual variou em função do tipo de resina acrílica. O tipo de resina acrílica e o ciclo de polimerização a que foram submetidas não interferiram na absorção de água. Os ciclos térmicos de polimerização em água e em microondas não interferiram na porosidade apresentada pela resina acrílica termo polimerizável convencional. A porosidade superficial variou em função do tipo de resina acrílica avaliada. / This comparative evaluation of porosity, water sorption and residual monomer presented by acrylic resins was conducted, looking for excellence and rapidity in the confection of eye prostheses. Four groups, comprising of 15 specimens each, were established and submitted to polymerization cycles: Group 1 - conventional heat polymerizing acrylic resin / conventional heat-polymerization cycle; Group 2 - microwave acrylic resin / microwave cycle; Group 3 - conventional heat polymerizing acrylic resin / microwave cycle; Group 4 - cross-linked auto-polymerizing acrylic resin / auto-polymerizing process. Residual monomer liberation was determined by spectrophotometry during 11 days period. Water sorption was calculated by weighting dried specimens and weighting after 7 days of submersion in deionized water. Superficial porosity was determined by percentage of area, in images processed by the software ImageLab 2000®. Subjecting data to ANOVA/TUKEY test (p<=0,05) it was observed that residual monomer liberation was higher in the first day for Group 1, similar during all the period for Group 2, lower after day 8 for Group 3 and decreasing until day 8 for Group 4. Residual monomer liberation was similar to Groups 1 and 3, lower for Group 2 and higher for Group 4. Water sorption was similar to all groups. Group 2 displayed more superficial porosity, and Group 1 and 3 were similar regarding this test. In conclusion, conventional polymerization and microwave processes did not interfere in residual monomer liberation of conventional acrylic resin. The residual monomer liberation varied according the type of acrylic resin. Microwave cycle provided similar or smaller residual monomer liberation. The type of acrylic resin and the polymerization cycle utilized did not modify water sorption. The conventional heat polymerizing cycle and microwave cycle did not interfere in superficial porosity of conventional heat polymerizing acrylic resin. The superficial porosity varied according to the acrylic resin.
27

Avaliação dos efeitos adversos de soluções desinfetantes nas propriedades físicas e mecânicas de materiais para confecção de próteses totais / Evaluation of the adverse effects of disinfectant solutions on the physical and mechanical properties of materials for making complete dentures

Bueno, Frank Lucarini 23 January 2017 (has links)
O estudo avaliou os efeitos adversos de soluções desinfetantes sobre a dureza, alteração de cor, sorção e solubilidade, resistência à flexão, rugosidade e resistência ao impacto de uma resina acrílica e dentes artificiais. Microscopia confocal a laser foi utilizada para análise de superfície. Através da concentração inibitória mínima (CIM), utilizando o método de micro diluições, foi determinada a concentração de 0,15% para a solução de Triclosan e 0,25% para a Cloramina T. As variáveis foram mensuradas antes e após a imersão dos espécimes nas soluções. Os corpos de prova em resina acrílica termicamente ativada e os dentes artificiais foram distribuídos em grupos (n=10): GC = água destilada; GHS = Hipoclorito de sódio a 0,25%; GT = Solução de Triclosan a 0,15%; GCt = Solução de Cloramina T a 0,25%; GRc2 = solução de R. communis a 2%; GRc10 = solução de R. communis a 10%; GS = Sabonete Antisséptico. Os corpos de prova foram imersos em 100 mL de cada solução, simulando imersões diárias de 20 minutos por 5 anos. Os dados foram submetidos aos Testes ANOVA e Duncan ou ANOVA e Tukey (p=0,05). Para resina acrílica, todos os grupos diminuíram a dureza, tendo GC causado a maior diminuição (p=0,001). Nos demais grupos a diminuição da dureza foi semelhante. O grupo GRc2 apresentou a maior alteração de cor, enquanto o GCt causou a menor. Os demais grupos apresentaram valores intermediários (p=0,043). Em relação à sorção, o grupo GRc2 seguido do GC apresentaram maior valor de sorção e os grupos GT e GS, os menores. Para a solubilidade, os grupos GC, GHS, GCt, GT e GS apresentaram os maiores valores, e o grupo GRc2 seguido do GRc10 apresentou o menor valor (p=0,001). O menor valor de resistência a flexão foi verificado no GRc2, enquanto os grupos GC e GCt apresentaram os maiores valores (p=0,000). Os demais grupos apresentaram valores intermediários. Todas as soluções causaram diminuição da rugosidade exceto os grupos Rc10 e GC (p=0,001). Os grupos GS, GT e GCt apresentaram os maiores valores de resistência ao impacto, e o GRc10 apresentou o menor valor (p=0,000). Já para os dentes, houve aumento da dureza em todos os grupos, tendo os grupos GHS e GC causado maior alteração (p=0,000). Os grupos GS e GRc2 apresentaram a maior alteração de cor, enquanto os grupos GC, GCt e GT apresentaram as menores (p=0,000). Os grupos GC, GRc2 e GRc10 apresentaram os maiores valores de sorção e os grupos GT e GS os menores. Para a solubilidade, os grupos GRc10 e GRc2 apresentaram os maiores valores e os grupos GT e GS, os menores. A variação da rugosidade dos dentes indicou que todas as soluções causaram diminuição da rugosidade exceto o grupo GT. A maior variação de rugosidade foi causada pela solução de Rc10 (p=0,001). No período avaliado, todas as propriedades sofreram alterações em função das soluções de desinfecção avaliadas após simulação de imersões diárias de 20 minutos por 5 anos, porém todas as variáveis estudas apresentaram valores clinicamente aceitáveis, exceto a alteração de cor. / This study evaluated the adverse effects of disinfectant solutions on hardness, color change, sorption and solubility, flexural strength, roughness and impact strength of an acrylic resin and artificial teeth. Confocal laser microscopy was used for surface analysis. The minimum inhibitory concentration (MIC) using the microdilution method determined the concentration of 0.15% for the Triclosan solution and 0.25% for the Chloramine T. Variables were measured before and after immersion of the specimens in the solutions. The thermally activated acrylic resin specimens and the artificial teeth were distributed in groups (n = 10): GC = distilled water; GHS = 0.25% Sodium hypochlorite; GT = 0.15% Triclosan solution; GCt = 0.25% Chloramine T solution; GRc2 = 2% R. communis solution; GRc10 = 10% R. communis solution; GS = Antiseptic Soap. The specimens were immersed in 100 mL of each solution, simulating daily immersions of 20 minutes for 5 years. The data obtained were submitted to ANOVA and Duncan tests or ANOVA and Tukey tests (p = 0.05). For acrylic resin, all groups decreased hardness and GC showed the greatest decrease (p = 0.001). In the other groups the decrease in hardness was similar. The GRc2 group presented the greatest color change, while the GCt, the lowest. The other groups presented intermediate values (p = 0.043). In relation to the sorption, the GRc2 group followed by the GC presented higher sorption value and the GT and GS groups, the smaller. For solubility, GC, GHS, GCt, GT and GS presented the highest values, and the GRc2 group followed by GRc10 had the lowest value (p = 0.001). The GRc2 showed a lower value of flexural strength, while GC and GCt had the highest values (p = 0.000). The other groups presented intermediate values. All solutions caused a decrease in roughness except the groups Rc10 and GC (p = 0.001). The groups GS, GT and GCt had the highest values of impact resistance, and the GRc10 had the lowest value (p = 0.000). For the teeth, there were an increase on hardness in all groups, and the GHS and CG groups showed a greater change (p = 0.000). The GS and GRc2 groups had the highest color change, while the GC, GCt and GT groups showed the lowest (p = 0.000). The GC, GRc2 and GRc10 groups had the highest sorption values and the GT and GS groups had the lowest values. For the solubility, the GRc10 and GRc2 groups had the highest values and the GT and GS groups, the lowest. The variation of the roughness of the teeth indicated that all solutions caused a decrease in roughness except for the GT group. The highest roughness variation was caused by the Rc10 solution (p = 0.001). In the evaluated period, all the properties were altered as a function of the disinfection solutions evaluated after simulation of daily immersions of 20 minutes for 5 years, however all variables studied presented clinically acceptable values, except for color change.
28

Avaliação dos efeitos adversos de soluções desinfetantes nas propriedades físicas e mecânicas de materiais para confecção de próteses totais / Evaluation of the adverse effects of disinfectant solutions on the physical and mechanical properties of materials for making complete dentures

Frank Lucarini Bueno 23 January 2017 (has links)
O estudo avaliou os efeitos adversos de soluções desinfetantes sobre a dureza, alteração de cor, sorção e solubilidade, resistência à flexão, rugosidade e resistência ao impacto de uma resina acrílica e dentes artificiais. Microscopia confocal a laser foi utilizada para análise de superfície. Através da concentração inibitória mínima (CIM), utilizando o método de micro diluições, foi determinada a concentração de 0,15% para a solução de Triclosan e 0,25% para a Cloramina T. As variáveis foram mensuradas antes e após a imersão dos espécimes nas soluções. Os corpos de prova em resina acrílica termicamente ativada e os dentes artificiais foram distribuídos em grupos (n=10): GC = água destilada; GHS = Hipoclorito de sódio a 0,25%; GT = Solução de Triclosan a 0,15%; GCt = Solução de Cloramina T a 0,25%; GRc2 = solução de R. communis a 2%; GRc10 = solução de R. communis a 10%; GS = Sabonete Antisséptico. Os corpos de prova foram imersos em 100 mL de cada solução, simulando imersões diárias de 20 minutos por 5 anos. Os dados foram submetidos aos Testes ANOVA e Duncan ou ANOVA e Tukey (p=0,05). Para resina acrílica, todos os grupos diminuíram a dureza, tendo GC causado a maior diminuição (p=0,001). Nos demais grupos a diminuição da dureza foi semelhante. O grupo GRc2 apresentou a maior alteração de cor, enquanto o GCt causou a menor. Os demais grupos apresentaram valores intermediários (p=0,043). Em relação à sorção, o grupo GRc2 seguido do GC apresentaram maior valor de sorção e os grupos GT e GS, os menores. Para a solubilidade, os grupos GC, GHS, GCt, GT e GS apresentaram os maiores valores, e o grupo GRc2 seguido do GRc10 apresentou o menor valor (p=0,001). O menor valor de resistência a flexão foi verificado no GRc2, enquanto os grupos GC e GCt apresentaram os maiores valores (p=0,000). Os demais grupos apresentaram valores intermediários. Todas as soluções causaram diminuição da rugosidade exceto os grupos Rc10 e GC (p=0,001). Os grupos GS, GT e GCt apresentaram os maiores valores de resistência ao impacto, e o GRc10 apresentou o menor valor (p=0,000). Já para os dentes, houve aumento da dureza em todos os grupos, tendo os grupos GHS e GC causado maior alteração (p=0,000). Os grupos GS e GRc2 apresentaram a maior alteração de cor, enquanto os grupos GC, GCt e GT apresentaram as menores (p=0,000). Os grupos GC, GRc2 e GRc10 apresentaram os maiores valores de sorção e os grupos GT e GS os menores. Para a solubilidade, os grupos GRc10 e GRc2 apresentaram os maiores valores e os grupos GT e GS, os menores. A variação da rugosidade dos dentes indicou que todas as soluções causaram diminuição da rugosidade exceto o grupo GT. A maior variação de rugosidade foi causada pela solução de Rc10 (p=0,001). No período avaliado, todas as propriedades sofreram alterações em função das soluções de desinfecção avaliadas após simulação de imersões diárias de 20 minutos por 5 anos, porém todas as variáveis estudas apresentaram valores clinicamente aceitáveis, exceto a alteração de cor. / This study evaluated the adverse effects of disinfectant solutions on hardness, color change, sorption and solubility, flexural strength, roughness and impact strength of an acrylic resin and artificial teeth. Confocal laser microscopy was used for surface analysis. The minimum inhibitory concentration (MIC) using the microdilution method determined the concentration of 0.15% for the Triclosan solution and 0.25% for the Chloramine T. Variables were measured before and after immersion of the specimens in the solutions. The thermally activated acrylic resin specimens and the artificial teeth were distributed in groups (n = 10): GC = distilled water; GHS = 0.25% Sodium hypochlorite; GT = 0.15% Triclosan solution; GCt = 0.25% Chloramine T solution; GRc2 = 2% R. communis solution; GRc10 = 10% R. communis solution; GS = Antiseptic Soap. The specimens were immersed in 100 mL of each solution, simulating daily immersions of 20 minutes for 5 years. The data obtained were submitted to ANOVA and Duncan tests or ANOVA and Tukey tests (p = 0.05). For acrylic resin, all groups decreased hardness and GC showed the greatest decrease (p = 0.001). In the other groups the decrease in hardness was similar. The GRc2 group presented the greatest color change, while the GCt, the lowest. The other groups presented intermediate values (p = 0.043). In relation to the sorption, the GRc2 group followed by the GC presented higher sorption value and the GT and GS groups, the smaller. For solubility, GC, GHS, GCt, GT and GS presented the highest values, and the GRc2 group followed by GRc10 had the lowest value (p = 0.001). The GRc2 showed a lower value of flexural strength, while GC and GCt had the highest values (p = 0.000). The other groups presented intermediate values. All solutions caused a decrease in roughness except the groups Rc10 and GC (p = 0.001). The groups GS, GT and GCt had the highest values of impact resistance, and the GRc10 had the lowest value (p = 0.000). For the teeth, there were an increase on hardness in all groups, and the GHS and CG groups showed a greater change (p = 0.000). The GS and GRc2 groups had the highest color change, while the GC, GCt and GT groups showed the lowest (p = 0.000). The GC, GRc2 and GRc10 groups had the highest sorption values and the GT and GS groups had the lowest values. For the solubility, the GRc10 and GRc2 groups had the highest values and the GT and GS groups, the lowest. The variation of the roughness of the teeth indicated that all solutions caused a decrease in roughness except for the GT group. The highest roughness variation was caused by the Rc10 solution (p = 0.001). In the evaluated period, all the properties were altered as a function of the disinfection solutions evaluated after simulation of daily immersions of 20 minutes for 5 years, however all variables studied presented clinically acceptable values, except for color change.
29

Avaliação in vitro do efeito da incorporação de clorexidina nas propriedades físicas e na atividade antibacteriana de resinas acrílicas autopolimerizáveis / Effect of the incorporation of chlorhexidine in provisional crown and bridge acrylic resins on their physical properties

Gabriela Czauski Amaral de Rojas 01 February 2012 (has links)
Objetivo. O objetivo do presente estudo foi avaliar o efeito da incorporação de diacetato de clorexidina (CDA), em diferentes concentrações e tempos de armazenamento, nas propriedades físicas e na atividade antibacteriana de resinas acrílicas, utilizadas na confecção de coroas e pontes provisórias. Métodos. Fase I: Foram confeccionados 150 corpos de prova retangulares (3,0 mm X 10 mm X 64 mm), de acordo com a norma ISO 1567 e 150 corpos de prova quadrados (10 mm X 10 mm X 2,0 mm), utilizando-se duas resinas acrílicas autopolimerizáveis, Duralay (Reliance Dental Mfg. Co.) e Dencor (Clássico). Os corpos de prova foram distribuídos em 30 grupos (n=10/grupo) de acordo com a concentração de CDA incorporada às resinas (p/p) (A) 0%, (B) 1%, (C) 2%, (D) 4%, (E) 5%, em função do tempo de armazenamento em água destilada, a 37C (T0 2h, T1 7 dias, T2 30 dias). Foram realizados os ensaios de microdureza Knoop, em microdurômetro Micromet 5104, Buehler (N), rugosidade superficial (Ra), em rugosímetro digital Mitutoyo Surftest SJ-201 (n=5) e resistência à flexão em três pontos (MPa), em uma máquina de ensaio universal EMIC MF 200 DL (n=5). Fase II: Adicionalmente, a atividade antibacteriana dos materiais sobre Streptococcus mutans foi determinada através da realização de testes de difusão em meio BHI, sendo para isso confeccionados 30 corpos de prova em forma de disco (12 mm X 3,0 mm) com as mesmas 5 concentrações (n=3/grupo). Os resultados foram tabulados e submetidos à análise estatística three-way ANOVA (Fase I) e two-way ANOVA (Fase II). Resultados. ANOVA mostrou que a adição de CDA não provocou alteração significativa na resistência à flexão dos materiais testados. A resistência à flexão é inversamente proporcional ao tempo para a resina Dencor e diretamente proporcional ao tempo para a resina Duralay. Houve aumento da microdureza com o acréscimo de CDA ao material Dencor com relação ao grupo controle, enquanto que no material Duralay a CDA não interferiu significativamente nesta propriedade. A rugosidade superficial aumentou significativamente (p<0,001) com o tempo e com o aumento da concentração de clorexidina na resina Dencor e não provocou alteração significativa em Duralay. Os testes de difusão em ágar demonstraram atividade antimicrobiana significativa (p<0,05) em todos os grupos, quando comparados ao grupo-controle. A inibição ao crescimento de Streptococcus mutans foi maior com o aumento da concentração desta substância. A resina Dencor apresentou maior halo de inibição do que a resina Duralay. Conclusões. Os resultados deste estudo sugerem que a incorporação de clorexidina aos materiais testados exibiu efeito antibacteriano contra S. mutans, sem contudo afetar de maneira crítica as propriedades físicas avaliadas. / Objectives. This study evaluated the effect of the incorporation of chlorhexidine diacetate salt hydrate (CDA) on the hardness, roughness and flexural strength (FS) of provisional crown and bridge acrylic resins. Methods. Step I: One hundred fifty specimens (3,0 mm X 10 mm X 64 mm) and one hundred fifty specimens (10 mm X 10 mm X 2,0 mm) of the autopolymerizing resins: Duralay (Reliance Dental Mfg. Co.) and Dencor (Clássico) were prepared, according to the ISO 1567 specification. The specimens were divided into 30 groups (n=10/group) according to the concentration of CDA (w/w): (A) 1%, (B) 2%, (C) 4%, (D) 5%, (E) 0% and the storage time in distilled water at 37C, after mixing (T0 2h, T1 7 days, T2 30 days). The surface hardness was assessed using a Knoop Hardness test (KHN), the surface roughness measurements (Ra) were made using a surface roughness tester Mitutoyo Surftest SJ-201 (n=5) and the FS were tested using a 3-point bending test (n=5). Step II: Additionally, antibacterial study was performed by observing the presence of inhibition zone against Streptococcus mutans. For this test, 30 set disc-shaped specimens (12 mm X 3 mm) were prepared with the same 5 concentrations of chlorhexidine (n=3/group). Results. ANOVA showed that the addition of CDA had not a significantly lower effect on flexural strength of the tested materials. The flexural strength is inversely proportional to the time for Dencor and directly proportional for Duralay. There was a decrease of microhardness with the increase of CDA concentration on Dencor samples in relation to the control group, whereas the addition of CDA did not interfere in this property for Duralay. Surface roughness significantly increased (p<0,001) over time and increasing concentration of CDA for Dencor and did not cause significant change in Duralay. The agar diffusion test showed that all the tested groups had significant antibacterial activity against S. mutans, compared to the control group (p<0,05) and there were no difference between the resins. Increasing concentration of the substance produced greater inhibition. Conclusions. The results of this study suggested that the incorporation of CDA to the materials tested exhibited antibacterial effects against S. mutans, without compromising its physical properties.
30

EFEITO DO ACABAMENTO DE SUPERFÍCIE NA ESTABILIDADE DE COR DE RESINAS PARA PROVISÓRIO SUBMETIDAS A DESAFIO CORANTE / EFFECT OF SURFACE FINISHING ON COLOR STABILITY OF RESINS FOR PROVISIONALS SUBMITTED TO STAINING CHALLENGE

Garlet, Katia 25 August 2014 (has links)
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior / The purpose of this study was to investigate the effect of surface finishing on the color stability of the resins used for provisional restorations when immersed in staining agent in different times (7, 30, and 60 days). Thirty-six disc-shaped specimens (sp) were built up for each type of resin: Duralay (polymethylmethacrylate), Trim II (polyethylmethacrylate) and Protemp 4 (bis-acrylic). The sp were prepared using a muffle with the use of a matrix with dimensions of 10x3 mm. Resins were inserted in the muffle, pressed with 1500 kgf and sp were removed after 15 min. The sp were randomly divided into 2 groups: one was finished with 150-grit sandpaper (rough group) and the other with 150 to 1200-grit sandpapers sequence (polished group). These groups were subdivided into two types of immersion: red wine and saliva (control). Specimens from the wine group were immersed 10 minutes per day and were maintained in saliva along the remained period. Specimens from control group were kept in saliva which was changed every 3 days. The color change (ΔE) was measured with the spectrophotometer SP60 using the CIE L*a*b* system. Data were statistically analyzed by ANOVA and Tukey test (5%). The effect of surface, material and time was statistically significant in red wine (p <0.05). The methylmethacrylate-based resin was superior to the other materials in both storage media, in all periods and in polished and rough surfaces. / O objetivo deste trabalho foi investigar o efeito do acabamento de superfície na estabilidade de cor das resinas utilizadas para confecção de restaurações provisórias submetidas a desafio corante em períodos distintos (7, 30 e 60 dias). Foram confeccionados 36 corpos de prova (cps) em forma de disco para cada tipo de resina: Duralay (polimetilmetacrilato), Trim II (polietilmetacrilato) e Protemp 4 (bis-acril). Os cps foram confeccionados em mufla através de uma matriz com dimensões de 10x3 mm. As resinas foram inseridas na mufla, prensadas com 1500 kgf e os cps removidos após 15 min. Os cps foram aleatoriamente divididos em 2 grupos, sendo que um recebeu acabamento de superfície com lixa d água granulação 150 (grupo rugoso) e o outro acabamento com sequência de lixas de 150 a 1200 (grupo polido). Esses grupos foram subdivididos em dois tipos de imersão: vinho tinto e saliva (controle). Os cps do grupo vinho receberam imersões diárias de 10 minutos e no restante do tempo eram mantidos em saliva. Os cps do grupo controle permaneceram em saliva, que era renovada a cada 3 dias. A alteração de cor (ΔE*) foi medida pelo espectrofotômetro SP60 utilizando o sistema CIE L*a*b*. Os dados foram analisados estatisticamente através de Análise de Variância com fator vinculado e Teste de Tukey (5%). O efeito da superfície, material e tempo foi estatisticamente significante em vinho (p<0,05). A resina à base de metilmetacrilato mostrou superioridade nos dois meios de imersão, em todos os tempos e nas superfícies polida e rugosa.

Page generated in 0.0734 seconds