• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 49
  • 2
  • Tagged with
  • 51
  • 45
  • 44
  • 40
  • 17
  • 12
  • 10
  • 9
  • 9
  • 9
  • 8
  • 8
  • 7
  • 6
  • 6
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
31

Avaliação in vitro do efeito da incorporação de clorexidina nas propriedades físicas e na atividade antibacteriana de resinas acrílicas autopolimerizáveis / Effect of the incorporation of chlorhexidine in provisional crown and bridge acrylic resins on their physical properties

Gabriela Czauski Amaral de Rojas 01 February 2012 (has links)
Objetivo. O objetivo do presente estudo foi avaliar o efeito da incorporação de diacetato de clorexidina (CDA), em diferentes concentrações e tempos de armazenamento, nas propriedades físicas e na atividade antibacteriana de resinas acrílicas, utilizadas na confecção de coroas e pontes provisórias. Métodos. Fase I: Foram confeccionados 150 corpos de prova retangulares (3,0 mm X 10 mm X 64 mm), de acordo com a norma ISO 1567 e 150 corpos de prova quadrados (10 mm X 10 mm X 2,0 mm), utilizando-se duas resinas acrílicas autopolimerizáveis, Duralay (Reliance Dental Mfg. Co.) e Dencor (Clássico). Os corpos de prova foram distribuídos em 30 grupos (n=10/grupo) de acordo com a concentração de CDA incorporada às resinas (p/p) (A) 0%, (B) 1%, (C) 2%, (D) 4%, (E) 5%, em função do tempo de armazenamento em água destilada, a 37C (T0 2h, T1 7 dias, T2 30 dias). Foram realizados os ensaios de microdureza Knoop, em microdurômetro Micromet 5104, Buehler (N), rugosidade superficial (Ra), em rugosímetro digital Mitutoyo Surftest SJ-201 (n=5) e resistência à flexão em três pontos (MPa), em uma máquina de ensaio universal EMIC MF 200 DL (n=5). Fase II: Adicionalmente, a atividade antibacteriana dos materiais sobre Streptococcus mutans foi determinada através da realização de testes de difusão em meio BHI, sendo para isso confeccionados 30 corpos de prova em forma de disco (12 mm X 3,0 mm) com as mesmas 5 concentrações (n=3/grupo). Os resultados foram tabulados e submetidos à análise estatística three-way ANOVA (Fase I) e two-way ANOVA (Fase II). Resultados. ANOVA mostrou que a adição de CDA não provocou alteração significativa na resistência à flexão dos materiais testados. A resistência à flexão é inversamente proporcional ao tempo para a resina Dencor e diretamente proporcional ao tempo para a resina Duralay. Houve aumento da microdureza com o acréscimo de CDA ao material Dencor com relação ao grupo controle, enquanto que no material Duralay a CDA não interferiu significativamente nesta propriedade. A rugosidade superficial aumentou significativamente (p<0,001) com o tempo e com o aumento da concentração de clorexidina na resina Dencor e não provocou alteração significativa em Duralay. Os testes de difusão em ágar demonstraram atividade antimicrobiana significativa (p<0,05) em todos os grupos, quando comparados ao grupo-controle. A inibição ao crescimento de Streptococcus mutans foi maior com o aumento da concentração desta substância. A resina Dencor apresentou maior halo de inibição do que a resina Duralay. Conclusões. Os resultados deste estudo sugerem que a incorporação de clorexidina aos materiais testados exibiu efeito antibacteriano contra S. mutans, sem contudo afetar de maneira crítica as propriedades físicas avaliadas. / Objectives. This study evaluated the effect of the incorporation of chlorhexidine diacetate salt hydrate (CDA) on the hardness, roughness and flexural strength (FS) of provisional crown and bridge acrylic resins. Methods. Step I: One hundred fifty specimens (3,0 mm X 10 mm X 64 mm) and one hundred fifty specimens (10 mm X 10 mm X 2,0 mm) of the autopolymerizing resins: Duralay (Reliance Dental Mfg. Co.) and Dencor (Clássico) were prepared, according to the ISO 1567 specification. The specimens were divided into 30 groups (n=10/group) according to the concentration of CDA (w/w): (A) 1%, (B) 2%, (C) 4%, (D) 5%, (E) 0% and the storage time in distilled water at 37C, after mixing (T0 2h, T1 7 days, T2 30 days). The surface hardness was assessed using a Knoop Hardness test (KHN), the surface roughness measurements (Ra) were made using a surface roughness tester Mitutoyo Surftest SJ-201 (n=5) and the FS were tested using a 3-point bending test (n=5). Step II: Additionally, antibacterial study was performed by observing the presence of inhibition zone against Streptococcus mutans. For this test, 30 set disc-shaped specimens (12 mm X 3 mm) were prepared with the same 5 concentrations of chlorhexidine (n=3/group). Results. ANOVA showed that the addition of CDA had not a significantly lower effect on flexural strength of the tested materials. The flexural strength is inversely proportional to the time for Dencor and directly proportional for Duralay. There was a decrease of microhardness with the increase of CDA concentration on Dencor samples in relation to the control group, whereas the addition of CDA did not interfere in this property for Duralay. Surface roughness significantly increased (p<0,001) over time and increasing concentration of CDA for Dencor and did not cause significant change in Duralay. The agar diffusion test showed that all the tested groups had significant antibacterial activity against S. mutans, compared to the control group (p<0,05) and there were no difference between the resins. Increasing concentration of the substance produced greater inhibition. Conclusions. The results of this study suggested that the incorporation of CDA to the materials tested exhibited antibacterial effects against S. mutans, without compromising its physical properties.
32

Avaliação da liberação de monômero residual, absorção de água e porosidade superficial em resinas acrílicas para prótese ocular / Evaluation of residual monomer, water sorption and porosity by acrylic resins used to eye prostheses

Rodrigo Elias de Oliveira 07 March 2008 (has links)
A necessidade do aprimoramento das técnicas de confecção de próteses oculares que permitam satisfazer, com rapidez e excelência, a demanda de atendimento de pacientes portadores de perdas do bulbo ocular, levou ao desenvolvimento deste estudo comparativo no qual se avalia a porosidade superficial, absorção de água e liberação de monômero residual de resinas acrílicas. Foram estabelecidos quatro grupos de estudo, sendo cada grupo composto por 15 corpos de prova: Grupo 1 - resina acrílica termo polimerizável convencional / ciclo térmico convencional; Grupo 2 - resina acrílica termo polimerizável em microondas / ciclo microondas; Grupo 3 - resina acrílica termo polimerizável convencional / ciclo microondas; Grupo 4 - resina acrílica auto polimerizável com cadeia cruzada / auto polimerização. A avaliação da quantidade de monômero residual liberado foi realizada por meio de espectrofotometria, durante o período de 11 dias. A determinação da absorção de água baseou-se na diferença do peso apresentado pelos corpos de prova nas condições experimentais seco e após submersão em água deionizada por um período de 7 dias. A determinação da porosidade superficial foi calculada sob a forma de porcentagem por área de superfície analisada, empregando-se lupa estereoscópica para captação da imagem a ser processada pelo software ImageLab 2000®. Submetendo-se os dados à análise estatística ANOVA/TUKEY (p<=0,05) observou-se que a liberação de monômero residual foi significantemente maior no primeiro dia para o Grupo 1, semelhante durante todo o período para o Grupo 2, menor a partir do dia 8 para o Grupo 3 e decrescente até o dia 8 para o Grupo 4. A liberação de monômero residual foi semelhante para os Grupos 1 e 3, menor para o Grupo 2 e maior para o Grupo 4. A absorção de água foi semelhante para os quatro grupos de estudo. A maior porosidade ocorreu no Grupo 2, sendo os Grupos 1 e 3 semelhantes entre si. Concluiu-se que os ciclos térmicos de polimerização em água e em microondas não interferiram na liberação de monômero residual da resina acrílica termo polimerizável convencional. A liberação de monômero residual variou em função do tipo de resina acrílica. O tipo de resina acrílica e o ciclo de polimerização a que foram submetidas não interferiram na absorção de água. Os ciclos térmicos de polimerização em água e em microondas não interferiram na porosidade apresentada pela resina acrílica termo polimerizável convencional. A porosidade superficial variou em função do tipo de resina acrílica avaliada. / This comparative evaluation of porosity, water sorption and residual monomer presented by acrylic resins was conducted, looking for excellence and rapidity in the confection of eye prostheses. Four groups, comprising of 15 specimens each, were established and submitted to polymerization cycles: Group 1 - conventional heat polymerizing acrylic resin / conventional heat-polymerization cycle; Group 2 - microwave acrylic resin / microwave cycle; Group 3 - conventional heat polymerizing acrylic resin / microwave cycle; Group 4 - cross-linked auto-polymerizing acrylic resin / auto-polymerizing process. Residual monomer liberation was determined by spectrophotometry during 11 days period. Water sorption was calculated by weighting dried specimens and weighting after 7 days of submersion in deionized water. Superficial porosity was determined by percentage of area, in images processed by the software ImageLab 2000®. Subjecting data to ANOVA/TUKEY test (p<=0,05) it was observed that residual monomer liberation was higher in the first day for Group 1, similar during all the period for Group 2, lower after day 8 for Group 3 and decreasing until day 8 for Group 4. Residual monomer liberation was similar to Groups 1 and 3, lower for Group 2 and higher for Group 4. Water sorption was similar to all groups. Group 2 displayed more superficial porosity, and Group 1 and 3 were similar regarding this test. In conclusion, conventional polymerization and microwave processes did not interfere in residual monomer liberation of conventional acrylic resin. The residual monomer liberation varied according the type of acrylic resin. Microwave cycle provided similar or smaller residual monomer liberation. The type of acrylic resin and the polymerization cycle utilized did not modify water sorption. The conventional heat polymerizing cycle and microwave cycle did not interfere in superficial porosity of conventional heat polymerizing acrylic resin. The superficial porosity varied according to the acrylic resin.
33

Efeito da triazina nas propriedades mecânicas e formação de biofilme em resina acrílica e reembasadores de prótese / Antimicrobial activity of triazine added to denture materials on saliva-derived microcosms: microbiological efficacy and mechanical properties

Moraes, Aline Pinheiro de 01 April 2011 (has links)
Made available in DSpace on 2014-08-20T14:30:16Z (GMT). No. of bitstreams: 1 Dissertacao_Aline Pinheiro_Moraes.pdf: 846337 bytes, checksum: 66b01044077d89e98213868cd5b7582a (MD5) Previous issue date: 2011-04-01 / Candidiasis is the most common fungal infection in denture wearers. The association between Candida and denture base is directly related to the efficiency of this micro-organism to adhere and colonize these surfaces, which is an essential initial step for the development of denture-related stomatitis. Additionally, the use of denture liners has increased, with these materials more prone to microbial adhesion when compared with acrylic resin due to its higher surface roughness. These materials have demonstrated capacity to interact with oral micro-organisms.This important problem is the reason why several attempts have been made to develop biomaterials containing antifungal. Thus, the aim of this study was to investigate the potential antifungal activity of triazine added to acrylic resin and liners used in prosthodontics using microcosms biofilm model with saliva derived from patients with or without candidiasis, verifying its effectiveness in reducing microbial adherence and consequently reduce the incidence of Candida infections. The mechanical properties of the tested materials after the incorporation of triazine were also evaluated. We considered four commercially available materials (a microwave-cured acrylic resin and two soft denture liners and one hard denture liner) to which were added different concentrations of triazine (0; 2.5; 5.0 and 10%). The results indicated that no difference were found among triazine concentrations in acrylic resin flexural strength (p= 0.059). Triazine addition did not result in surface roughness changes, although all denture liners presented higher surface roughness compared with acrylic resin, while in general, SoftConfort presented the highest roughness (p<0.001). In general, 5 and 10% triazine addition resulted in more soluble materials. All materials presented increased water sorption with the addition of triazine (p<0.05), except for CoeSoft, where no change was observed. Candidiasis patient saliva presented higher counts of total micro-organisms (p= 0.0294) and total streptococci (p = 0.0008). Regarding materials, total streptococci, total micro-organisms and Candida counts were higher in CoeSoft (p<0.0001). Candida species counts was the same for both saliva donors (p>0.05). The addition of triazine did not result in decrease of total micro-organisms, total streptococci or Candida species in all materials tested (p>0.05). In conclusion, the addition of triazine to acrylic resin and denture liners in a complex biofilm model did not modify the development of biofilms in both patients with and without candidiasis / A candidíase é a infecção oral fúngica mais comum em usuários de próteses. A associação entre o microrganismo Candida e as bases das próteses está diretamente relacionada à eficiência deste microrganismo em aderir e colonizar estas superfícies, sendo esta a etapa inicial essencial para o desenvolvimento da estomatite induzida por prótese. Associado a isto, o uso de reembasadores para próteses tem aumentado, sendo estes materiais mais propensos à adesão microbiana quando comparados a resina acrílica devido a sua maior rugosidade de superfície. Além disso, estes materiais tem demonstrado capacidade de interagir com microrganismos bucais. Este importante problema tem levado a tentativa de desenvolvimento de diversos materiais contendo agentes antifúngicos. Assim, o objetivo deste estudo foi investigar o potencial antifúngico da triazina adicionada à resina acrílica e reembasadores utilizados em prótese dentária, através de um modelo de biofilme de microcosmos, com salivas derivadas de pacientes com ou sem candidíase, verificando sua efetividade em reduzir a adesão microbiana e, consequentemente, diminuir a incidência de infecções por Candida. Também avaliaram-se as propriedades mecânicas dos materiais testados após a incorporação da triazina. Foram considerados quatro materiais comercialmente disponíveis (uma resina acrílica ativada por energia de micro-ondas, dois reembasadores resilientes e um reembasador permanente), aos quais foram adicionadas diferentes concentrações de triazina (0; 2,5; 5,0 e 10%). Os resultados indicaram que não houve diferença (p = 0,059) entre as concentrações de triazina para a resina acrílica de micro-ondas no teste de resistência à flexão. Em relação a rugosidade de superfície, embora a adição de triazina não tenha levado ao aumento da rugosidade, os reembasadores apresentaram maior rugosidade que a resina acrílica, com o SoftConfort apresentando, em geral, a maior rugosidade (p<0,001). De maneira geral, quando adicionada triazina a 5,0 e 10%, todos os materiais tornaram-se mais solúveis e apresentaram aumento de sorção de água (p<0,05), a exceção do CoeSoft, que não mostrou diferença com a adição do composto químico. Houve diferença entre salivas, sendo que aquela proveniente de individuo com candidíase apresentou maiores contagens de microrganismos totais (p = 0,0294) e estreptococos totais (p = 0,0008). Em relação aos materiais, a contagem de estreptococos, microrganismos totais e espécies de Candida foi maior no CoeSoft (p<0,0001). Entretanto, a contagem de espécies de Candida foi igual entre os doadores (p>0,05). A adição de triazina não resultou em diminuição de microrganismos totais, estreptococos totais ou espécies de Candida em nenhum dos materiais testados (p>0,05). Como conclusão, a adição de triazina a resina acrílica e reembasadores utilizados para confecção de base e reembasamento de próteses em um modelo complexo de biofilme não modificou o desenvolvimento de biofilmes em ambos os pacientes com ou sem candidíase
34

EFEITO DE SOLUÇÕES HIGIENIZADORAS NA ESTABILIDADE DE COR E RUGOSIDADE DE RESINAS ACRÍLICAS PARA BASE DE DENTADURA / EFFECT OF CLEANING SOLUTIONS ON THE COLOR STABILITY AND ROUGHNESS OF DENTURE BASE ACRYLIC RESINS

Nora, Bárbara Dala 21 July 2016 (has links)
The aim of the study was to evaluate the effect of cleaning substances in color stability and roughness of acrylic resins to base definitive or provisional dentures polymerized by different methods. The factors evaluated were the type of acrylic resin (autopolymerized, heat-polymerized or microwave-polymerized), immersion media (alkaline peroxide, 0,5% sodium hypochlorite or artificial saliva as control) and time. Seventy-two disc-shaped specimens (8mmx2mm) were prepared (n = 8) and divided according to the experimental design. To determine color change (ΔE00) was used CIEDE2000 equation. The Ra parameter was used to determine the surface roughness of the samples. Baseline measurements were performed 24 hours after hydration (T0) and then the cps were subjected to 20 minutes daily immersions in media. New readings were performed in 30 (T1), 60 (T2) and 90 days (T3). Data were submitted to Analysis of Variance Test for Repeated Measures (Two-way ANOVA) followed by Tukey s Test (p <0,05). Significant effect was found over time, especially in color values (T2 and T3) and roughness for the autopolymerized resin (T3), which behaved worse. The solutions influenced color and roughness. Color stability and roughness were modified by means of immersion and varied depending on the type of polymerization, however the protocol of 20 minutes of immersion in cleaning solutions proved to be safe within the evaluated period for heat-polymerized and microwave-polymerized resin. / O objetivo do estudo foi avaliar o efeito substâncias de higienização na estabilidade de cor e na rugosidade de resinas acrílicas para base de dentadura definitiva ou provisória, polimerizadas por diferentes métodos. Os fatores avaliados foram o tipo de resina acrílica (autopolimerizável, termopolimerizável ou cura por micro-ondas), meios de imersão (peróxido alcalino, hipoclorito de sódio a 0,5% ou saliva artificial como controle) e tempo. Setenta e dois corpos de prova (cps) em forma de disco (8mmx2mm) foram confeccionados (n=8) e divididos conforme delineamento experimental. Para determinar alteração de cor (ΔE00) foi utilizada a equação CIEDE2000. O parâmetro de Ra foi empregado para determinar a rugosidade superficial média das amostras. As mensurações iniciais foram feitas 24h após a hidratação (T0) e a seguir os cps foram submetidos a imersões diárias de 20 minutos nos meios. Novas leituras foram realizadas nos tempos de 30 (T1),60 (T2) e 90 dias (T3). Os dados foram submetidos à Análise de Variância com dois fatores para Medidas Repetidas seguido de Teste de Tukey (p<0,05). Efeito significativo foi encontrado ao longo do tempo, principalmente nos valores de cor (T2 e T3) e rugosidade da resina autopolimerizável (T3), a qual se comportou de maneira inferior. Os meios influenciaram cor e rugosidade. Estabilidade de cor e rugosidade foram modificadas pelos meios de imersão e variaram conforme o tipo de polimerização, porém o protocolo de imersão em 20 minutos nas soluções higienizadoras mostrouse seguro dentro do período avaliado para as resinas termopolimerizável e cura por micro-ondas.
35

Análise da alteração dimensional em guias cirúrgicos de resina acrílica após esterilização por meio de plasma de peróxido de hidrogênio / Analysis of dimensional alterations of resin acrylic surgical splints after hydrogen peroxide plasma sterilization

Shigeoka, Anderson Akio 30 September 2009 (has links)
O presente trabalho verificou a alteração dimensional dos guias cirúrgicos confeccionados em resina acrílica para cirurgia ortognática quando submetidos à esterilização por meio de plasma de peróxido de hidrogênio. Foram utilizados 15 corpos de prova confeccionados em resina acrílica quimicamente ativada a partir de moldes metálicos em três espessuras: 1,5 mm, 3,0 mm e 5,0 mm, em um total de 45. A imagem de cada corpo de prova foi digitalizada antes e após o processo de esterilização e processada pelo programa Photoshop® CS2. Foi realizada a vetorização das imagens pelo programa Corel Trace ® 12 para mensuração pelo programa Corel Drawn ® 12. Os resultados foram submetidos ao teste estatístico dos postos sinalizados de Wilcoxon, ao nível de significância de 0,05%. Os resultados obtidos foram que nos corpos de prova de 1,5 mm de espessura não houve diferença estatisticamente significante entre as mensurações realizadas antes e após o processo de esterilização (P>0,05), porem, nas espessuras de 3,0 mm e 5,0 mm houve pelo menos uma das medidas estatisticamente diferentes (p=0,011 e p=0,017, respectivamente). Fato este que nos levou a acreditar que o processo de esterilização não leva a alteração dimensional, porem em volumes maiores provavelmente houve uma contração de polimerização diretamente proporcional. / Dimensional alterations in surgical splints made of acrylic resin used in orthognathic surgery were evaluated after hydrogen peroxide gas plasma sterilization. Fifteen specimens of resin acrylic was made by a metal model master with three different thickness: 1,5 mm, 3,0 mm and 5,0 mm, totally 45 specimens. Specimens digital image was acquired before and after sterilization and process by Photoshop® CD2 software. The images were transformed in vector form by Corel Trace® 12 software. The measures were performed by Corel Draw® 12 software. The results were submitted to Wilcoxon statistic method, 0.05 level of confidence. The results showed no statistical differences in 1.5 mm specimens (p0,307) before and after sterilization process but, in 3.0 and 5.0 mm, there was at least one measure statistically different (p=0,011 and p=0,017, respectively). It was possible to conclude that the sterilization process did not lead to dimensional alteration but, in higher thickness probably had happen a proportional polymerization contraction.
36

Estudo in vitro da adaptação de retentores intra-radiculares fundidos, modelados com diferentes resinas acrílicas autopolimerizáveis / In vitro study of the fit of cast post and core, obtained from different acrylic resin patterns

Rennó, Denise Galhardo 21 September 2005 (has links)
Dentes tratados endodonticamente se encontram freqüentemente mutilados por cárie ou pelo próprio acesso ao canal. A estrutura dental remanescente necessita de tratamento especial para prevenir futuras fraturas. Quando uma grande parte da coroa dental foi perdida, é comum não haver retenção para a restauração na dentina remanescente. Nestas situações, uma restauração com retenção intracanal se faz necessária. Apenas a porção radicular pode oferecer a retenção apropriada para a instalação de uma coroa artificial estética e funcional. Diferentes técnicas podem ser usadas para a fabricação do retentor intra-radicular fundido. Neste estudo, foi escolhida a técnica direta para a confecção dos padrões de fundição em resina acrílica autopolimerizável. Usamos seis padrões metálicos com dimensões que simulavam dentes anteriores preparados para receber um retentor intra-radicular. Os condutos foram preenchidos com resina acrílica, usando um pincel bem fino, e pinos plásticos foram inseridos no interior dos canais. Após a polimerização do pino, adicionamos novas porções de resina acrílica para confecção das partes correspondentes aos núcleos. Essa técnica permite a correção de eventuais falhas, caso haja necessidade. Os padrões de fundição foram então incluídos em material de revestimento e fundidos em liga de níquel-cromo. O retentor intra-radicular fundido foi removido do revestimento e limpo. Apenas removemos os nódulos da superfície do metal, a qual recebeu, posteriormente, jateamento com óxido de alumínio. O objetivo deste estudo foi comparar a adaptação marginal de 54 retentores intra-radiculares fundidos, modelados com três resinas acrílicas autopolimerizáveis diferentes: 18 em DuraLay (Reliance Dental MFG Co., USA); 18 em Pattern Resin (GC Products, Japan); 18 em Cop Clas (Artigos Odontológicos Clássico Ltda., Brasil). Os retentores intra-radiculares fundidos foram assentados sobre os seis padrões metálicos. As fendas marginais foram observadas em microscópio eletrônico de varredura (MEV). As medições foram registradas e submetidas à análise estatística. Os resultados obtidos mostraram que: (1) Os retentores intra-radiculares fundidos obtidos de padrões de fundição modelados com a resina DuraLay mostraram-se significativamente melhor adaptados (42,31 µm ± 9,54 µm) quando comparados aos retentores intra-radiculares fundidos obtidos de padrões das resinas Pattern Resin (73,25 µm ± 32,86 µm) e Cop Clas (95,32 µm ± 45,02 µm) respectivamente; (2) Não houve diferença estatisticamente significante (p=0,273) na diferença média das fendas marginais dos retentores intra-radiculares fundidos modelados com a resina Pattern Resin e modelados com a resina Cop Clas (22,07 µm ± 13,13 µm). / Endodontically treated teeth are often mutilated by caries and access requirements. The remaining structure requires special treatment to prevent further destruction. When a large portion of the clinical crown has been lost, it is often impossible to achieve sufficient anchorage of a restoration in the remaining dentin. In such situations, a root-canal-retained restoration is required. Only the root portion can offer the needed retention for a functional and esthetic artificial crown. Different approaches can be taken to the fabrication of cast posts and cores. In this study, direct method was chosen to fashion it, by auto polymerizing acrylic resin. We used six standard metal patterns that simulate an anterior tooth prepared to receive cast post and core. Burn-out plastic patterns were fitted into the root canal and, using a fine sable hair brush, the polymer was introduced to fill the canal. After polymerization of the post, additional auto -polymerizing acrylic resin was added to form the core portion. This process can be repeated and correct if necessary. The acrylic resin patterns were then invested and casting was performed using nickel-chromium alloy. The cast was removed from investment. Cleaning was performed exclusively to remove the small positive nodules on the metal post and sandblast surface. The aim of this research was to compare the marginal fit of 54 cast posts constructed with three auto -polymerizing acrylic resins: 18 of DuraLay (Reliance Dental MFG Co., USA); 18 of Pattern Resin (GC Products, Japan); 18 of Cop Clas (Artigos Odontológicos Clássico Ltda., Brasil). The posts and cores were seated over the six standard metal patterns. Marginal discrepancies were bserved in scanning electron microscope (SEM). The measurements were registered and statistically analyzed. The results obtained showed that: (1) The cast post and core obtainedfrom DuraLay (42,31 µm ± 9,54 µm) had significant best fit than the cast post and core obtained from the others acrylic resins, Pattern Resin (73,25 µm ± 32,86 µm) and Cop Clas (95,32 µm ± 45,02 µm) respectively; (2) No significant statistic difference occur p=0,273) in the average marginal gap between the cast posts and cores obtained from Pattern Resin and Cop Class (22,07 µm ± 13,13 µm).
37

Avaliação da cor, corrosão e rugosidade superficial do titânio c.p., ligas metálicas e resina acrílica termopolimerizável sob a ação de soluções higienizadoras / Color, corrosion and surface roughness evaluation of titanium c.p., alloys and heat-polymerized acrylic resin under the action of daily hygiene solutions

Davi, Letícia Resende 03 May 2010 (has links)
A higienização das próteses parciais ou totais removíveis é fundamental para a durabilidade do tratamento e prevenção de patologias orais. O objetivo deste estudo foi avaliar o efeito de agentes higienizadores de prótese na cor, corrosão e rugosidade superficial do titânio c.p., ligas metálicas e resina acrílica termopolimerizável, simulando um período de 180 dias de higienização. Espécimes em formato de discos (12 mm x 3 mm) foram confeccionados em: titânio comercialmente puro (Tritan - Ti c.p.), liga de níquel-cromo-molibdênio-titânio (Vi-Star), liga de níquel-cromo (Fit Cast-SB Plus) e liga de níquel-cromo-berílio (Fit Cast-V). Cada disco fundido foi incluído em mufla previamente preparada por matrizes retangulares de teflon (38 mm x 18 mm x 4 mm), incorporando-se o disco metálico à resina acrílica termopolimerizável. Os corpos-de-prova (n=5) foram imersos em soluções dos agentes higienizadores: hipoclorito de sódio a 0,05%, Periogard, Cepacol, pastilha Corega Tabs, pastilha Medical Interporous e pastilha Polident 3 Minute. Como controle, foi utilizada a água deionizada. Foram realizados ensaios de estabilidade de cor por meio de espectrocolorímetro (Color-guide 45/0), resistência à corrosão por meio da análise visual da presença de manchas no metal e análise da alteração de massa (balança eletrônica analítica), e rugosidade superficial por meio de rugosímetro (Surftest SJ-201P). Além disso, foi realizada análise quantitativa de liberação de íons metálicos por meio de espectrometria de massa com plasma indutivamente acoplado (ICP-MS - ELAN DRC II). Os resultados de estabilidade de cor, alteração de massa e rugosidade foram submetidos à ANOVA e teste de Tukey (p< 0,05). Quanto à estabilidade de cor da resina acrílica termopolimerizável (E), houve diferença estatisticamente significante entre o titânio c.p. e as ligas. A resina associada ao Ti c.p. apresentou menor alteração de cor, enquanto que a resina associada à Fit Cast-SB Plus apresentou a maior alteração de cor (1,33 ± 1,11 e 5,06 ± 1,96, respectivamente). Com relação à presença de manchas no metal, o hipoclorito de sódio causou manchamento nos espécimes das ligas Vi-Star e Fit Cast-V. Quando avaliada a alteração de massa (g), o Cepacol e a pastilha Corega Tabs propiciaram maior perda de massa. Entre os metais, a amostra do Ti c.p. apresentou maior perda de massa. Quanto à rugosidade (Ra, µm) da resina, o Cepacol causou maior rugosidade, enquanto que a pastilha Corega Tabs e o Periogard propiciaram maior lisura no corpo-de-prova. A resina associada ao Ti c.p. e ao Fit Cast-SB Plus apresentaram maior rugosidade. Quanto à rugosidade do metal, os produtos de imersão não influenciaram nos resultados, mas a liga Fit Cast-SB Plus apresentou maior rugosidade após a imersão. A liberação de íons mais expressiva foi constatada nas ligas Vi-Star e Fit Cast-V após a imersão na pastilha Medical Interporous. Pode-se concluir que as ligas Vi-Star e Fit Cast-V podem ser consideradas seguras para a confecção de aparelhos protéticos removíveis, mas com a condição de não utilizar o hipoclorito de sódio a 0,05% ou a pastilha Medical Interporous para a higienização, pois causaram corrosão e maior liberação de íons, respectivamente. / The hygiene care of the removable partial and complete dentures is required for the longevity of the treatment and prevention of oral diseases. The aim of this study was to evaluate the effect of denture cleansers on color, corrosion and surface roughness of the commercially pure titanium, metal alloys and heat-polymerized acrylic resin, simulating a period of 180 days of hygiene. Disk-shaped specimens (12 mm x 3 mm) had been fabricated with commercially pure titanium (Tritan - Ti c.p.), nickel-chromium-molybdenum-titanium alloy (Vi-Star), nickel-chromium alloy (Fit Cast-SB Plus) and nickel-chromium-beryllium alloy (Fit Cast-V). Each cast disc was invested in the flasks previously prepared by Teflon rectangular matrices (38 mm x 18 mm x 4 mm), incorporating the metal disk to the heat-polymerized acrylic resin. The specimens (n= 5) had been immersed in the solutions: sodium hypochlorite 0.05%, Periogard, Cepacol, Corega Tabs, Medical Interporous and Polident 3 Minute. As a control, it was used deionized water. It was accomplished assays of color stability by means of a colorimeter (Color-guide 45/0), corrosion resistance by means of visual analysis of tarnishes on the metal and mass alteration analysis (analytical electronic balance), and surface roughness by means of a surface analyzer (Surftest SJ-201P). Besides, the quantitative analysis of metal ions release was accomplished by means of inductively coupled plasma mass spectrometry (ICP-MS - ELAN DRC II). Color stability, mass alteration and roughness results were submitted to ANOVA and Tukey test (p<0.05). Considering the color stability of the heat-polymerized acrylic resin (E), there were statistically significant difference between the titanium c.p. and the alloys. The resin associated with the Ti c.p. showed lesser color alteration, whereas the resin associated with Fit Cast-SB Plus showed the higher color alteration (1,33 ± 1,11 e 5,06 ± 1,96, respectively). In relation to the presence of tarnishes on the metals, the sodium hypochlorite caused tarnishes on specimens of the Vi-Star and Fit Cast-V alloys. When evaluated the mass alteration (g), Cepacol and Corega Tabs propitiated higher weight loss. Between the metals, the Ti c.p. samples showed greater weight loss. Considering the resin roughness (Ra, µm), Cepacol caused higher roughness, whereas Corega Tabs and Periogard propitiated greater smoothness on the specimens. The resin associated with the Ti c.p. and Fit Cast-SB Plus showed higher roughness. Considering the metal roughness, the immersion products did not influence on the results, but the Fit Cast-SB Plus showed greater roughness after immersion. The ionic release most significant was with the Vi-Star and Fit Cast-V alloys after immersion in Medical Interporous. It could be concluded that the Vi-Star and Fit Cast-V alloys can be considered safe for removable prosthesis finish, but with the condition of do not use sodium hypochlorite 0.05% or Medical Interporous tablet for hygiene, because they caused corrosion and greater ionic release, respectively.
38

Efeito da adição de fibras de vidro particuladas nas propriedades mecânicas de resinas acrílicas utilizadas para a confecção de placas oclusais / Effect of addition of the particulate glass fibers in mechanical properties of acrylic resins used for the making occlusal splints

Soares, Rodrigo Gonçalves 06 July 2010 (has links)
Placas oclusais são dispositivos intraorais utilizados no manejo de pacientes que apresentam desordens do sono, migrânia do tipo tensional e outros. No entanto são os cirurgiões dentistas que predominantemente utilizam as placas oclusais como tratamento do equilíbrio das arcadas dentárias nas disfunções temporomandibulares, prevenção de desgaste dental em pacientes com hábitos parafuncionais e na prevenção de traumas em atletas. Vários métodos têm sido empregados para reforçar resinas acrílicas, como reforço metálico e atualmente a incorporação de diferentes tipos de fibras tais como: carbono, polietileno e vidro. Contudo a adição de fibras de vidro com partículas menores em algumas propriedades mecânicas ainda permanecem desconhecidas. Objetivo: O objetivo desse estudo foi avaliar algumas propriedades mecânicas como a rugosidade de superfície, microdureza, módulo de elasticidade e resistência flexural em resinas acrílicas após a incorporação de fibras de vidro particuladas pré silanizadas. Material e método: Para avaliação das propriedades foram confeccionados vinte e quatro corpos de prova (65 x 10 x 3 mm) de cada marca comercial de resina acrílica, utilizadas para confecção de placas oclusais, Vipi Flash (autopolimerizável), Vipi Wave (termopolimerizável por calor de microondas), Vipi Crill, Lucitone e QC-20 (termopolimerizáveis por calor de banho de água), sendo doze corpos-de-prova controles, e doze experimentais, com adição de 10% em peso de fibras de vidro particuladas (Reforplás S/A, São Paulo, SP, Brasil). Após a realização do acabamento superficial dos corpos de prova com lixas de carborundum e feltros era realizada a avaliação da rugosidade superficial em rugosímetro (Mitutoyo®) com três leituras ao longo dos corpos-de-prova, a microdureza Vickers era analisada em um microdurômetro (Micro Hardness Tester, Shimadzu, Japan) com cinco mensurações em cada corpo-de-prova, e para avaliar os ensaios de resistência flexural e módulo de elasticidade os corpos-de-prova foram avaliados por meio uma máquina de ensaios universal (Emic DL 2000®, Emic, São José dos Pinhais, PR, Brasil), com velocidade de 5mm/min. Os dados foram analisados estatisticamente, usando testes paramétricos e não paramétricos, de acordo com a distribuição da amostra. Resultados: As médias e desvios padrões do teste de rugosidade superficial em Ra foram Vipi Flash sem fibra (0,10 ± 0,03); Vipi Flash com fibra (0,12 ± 0,01); Vipi Wave sem fibra (0,16 ± 0,02); Vipi Wave com fibra (0,13 ± 0,02); Vipi Cril sem fibra (0,12 ± 0,03); Vipi Crill com fibra (0,15 ± 0,03); Lucitone sem fibra (0,10 ± 0,02); Lucitone com fibra (0,09 ± 0,04); QC-20 sem fibra (0,11 ± 0,02) e QC-20 com fibra (0,18 ± 0,03). As médias e desvios-padrão ao teste de microdureza Knoop com relação às marcas comerciais foram: Vipi Flash sem fibra (15,35 ± 0,3); Vipi Flash com fibra (15,51 ± 0,4); Vipi Wave sem fibra (16,60 ± 0,8); Vipi Wave com fibra (17,25 ± 0,9); Vipi Cril sem fibra (17,78 ± 2,27); Vipi Crill com fibra (18,02 ± 1,0); Lucitone sem fibra (15,72 ± 0,3); Lucitone com fibra (16,69 ± 0,6); QC-20 sem fibra (15,91 ± 0,4) e QC-20 com fibra (15,63 ± 0,2). As médias e desvios-padrão ao teste de módulo de elasticidade foram: Vipi Flash sem fibra (2952,76 ± 292,12); Vipi Flash com fibra (3373,49 ± 403,76); Vipi Wave sem fibra (2511,69 ± 304,09); Vipi Wave com fibra (3225,01 ± 248,66); Vipi Cril sem fibra (2745,61± 288,86); Vipi Crill com fibra (3671,67 ± 329,91); Lucitone sem fibra (1904,53 ± 149,05); Lucitone com fibra (3056,87 ± 126,11); QC-20 sem fibra (1913,86 ± 147,80) e QC-20 com fibra (2858,32 ± 185,26). As médias e desvios-padrão ao teste de resistência flexural foram Vipi Flash sem fibra (81,62 ± 4,82); Vipi Flash com fibra (83,98 ± 4,98); Vipi Wave sem fibra (83,52 ± 8,79); Vipi Wave com fibra (88,98± 8,47); Vipi Cril sem fibra (64,17± 5,46); Vipi Crill com fibra (93,37 ± 9,97); Lucitone sem fibra (74,71± 9,43); Lucitone com fibra (87,29 ± 4,73); QC-20 sem fibra (75,80 ± 8,82) e QC-20 com fibra (81,67± 12,97). Conclusão: Conclui-se que a incorporação de fibras provocou alterações em praticamente todas as propriedades analisadas, sendo, portanto facilmente utilizável como um reforço adicional às resinas acrílicas. Com relação à dureza superficial as resinas acrílicas termopolimerizável por banho de água e termopolimerizável por calor de microondas apresentaram maiores valores quando comparados com a resina acrílica autopolimerizável. Além disso, a adição de fibras de vidro particuladas aumentou os valores de rugosidade de algumas resinas acrílicas Vipi Crill, Vipi Flash e Vipi Wave e se manteve constante nas resinas Lucitone e QC-20. A adição de fibra de vidro não aumentou significantemente a microdureza Knoop nos grupos em estudo. Com relação à resistência flexural as fibras de vidro particuladas aumentaram significantemente todos os valores, assim como o módulo de elasticidade das resinas acrílicas reforçadas pela adição de fibras de vidro. / Intraoral Occlusal splints are devices used in the management of patients with sleep disorders, migraine type tension and others. But dentists who are predominantly using the plates as a treatment of occlusal balance of the dental arches in temporomandibular disorders, prevention of tooth wear in patients with habits and prevention of injuries in athletes. Several methods have been used to strengthen acrylic resins, such as metal reinforcement and are currently incorporating different types of fibers such as carbon, polyethylene and glass. However the addition of glass fibers with smaller particles on mechanical properties are still unknown. Objective: The objective of this study was to evaluate some mechanical properties such as surface roughness, hardness, elastic modulus and flexural strength in acrylic resins after the incorporation of glass fiber particulate pre silanized. Methods: To evaluate the properties were made twenty-four specimens (65 x 10 x 3 mm) of each brand of acrylic resin, used for fabrication of occlusal splints, Vipi Flash (self-curing), Vipi Wave (by thermo microwave heat), Vipi CRILL, Lucitone and QC-20 (thermo heat water bath), with twelve specimes controls, and twelve experimental, with the addition of 10 wt% glass fiber particulate (Reforplás S / A, São Paulo, Brazil). After completion of the roughness of the specimens with grit carborundum and felt it was evaluated the surface roughness on roughness tester (Mitutoyo ®) with three readings over the specimes, the microhardness was examined with a hardness ( Micro Hardness Tester, Shimadzu, Japan) with five measurements in each specime, and evaluate the tests for flexural strength and modulus of elasticity of the specimes was evaluated using a universal testing machine (Emic DL 2000 ®, Emic, São José dos Pinhais, PR, Brazil), with speed 5mm/min. The data were statistically analyzed using parametric and nonparametric tests, according to the sample distribution. Results: The mean and standard deviation of the test surface roughness were Vipi Flash without fiber (0.10 ± 0.03); Flash Vipi with fiber (0.12 ± 0.01); Vipi Wave without fiber (0, 16 ± 0.02); Vipi Wave with fiber (0.13 ± 0.02); Vipi Cril without fiber (0.12 ± 0.03); Vipi CRILL with fiber (0.15 ± 0.03); Lucitone without fiber (0.10 ± 0.02); Lucitone with fiber (0.09 ± 0.04), QC-20 fiber without (0.11 ± 0.02) and QC-20 with fiber (0.18 ± 0.03). Means and standard deviations for Knoop microhardness test with respect to trademarks were Vipi Flash without fiber (15.35 ± 0.3); Flash Vipi with fiber (15.51 ± 0.4); Vipi Wave without fiber (16.60 ± 0.8); Vipi Wave with fiber (17.25 ± 0.9); Vipi Cril without fiber (17.78 ± 2.27); Vipi CRILL with fiber (18.02 ± 1.0 ); Lucitone without fiber (15.72 ± 0.3); Lucitone with fiber (16.69 ± 0.6), QC-20 without fiber (15.91 ± 0.4) and QC-20 with fiber (15 , 63 ± 0.2). Means and standard deviations to test elastic modulus were Vipi Flash without fiber (2952.76 ± 292.12); Flash Vipi with fiber (3373.49 ± 403.76); Vipi Wave without fiber (2511.69 ± 304.09); Vipi Wave with fiber (3225.01 ± 248.66); Vipi Cril without fiber (2745.61 ± 288.86); Vipi CRILL with fiber (3671.67 ± 329.91); Lucitone without fiber (1904.53 ± 149.05); Lucitone with fiber (3056.87 ± 126.11), QC-20 without fiber (1913.86 ± 147.80) and QC-20 with fiber (2858.32 ± 185 26). Means and standard deviations for flexural strength were Vipi Flash without fiber (81.62 ± 4.82); Flash Vipi with fiber (83.98 ± 4.98); Vipi Wave without fiber (83.52 ± 8 , 79); Vipi Wave with fiber (88.98 ± 8.47); Vipi Cril without fiber (64.17 ± 5.46); Vipi CRILL with fiber (93.37 ± 9.97); Lucitone without fiber ( 74.71 ± 9.43); Lucitone with fiber (87.29 ± 4.73), QC-20 without fiber (75.80 ± 8.82) and QC-20 with fiber (81.67 ± 12.97). Conclusion: the conclusion is that the incorporation of fibers resulted in changes in almost all properties examined, and thus easily used as an additional reinforcement for acrylic resins. With respect to the surface roughness of acrylic resins by thermo water bath and microwave thermo heat showed higher values when compared with acrylic resin. Moreover, the addition of glass fiber particulate increased the roughness values of some acrylic resins Vipi CRILL, Vipi Flash and Vipi Wave and remained constant in the resins Lucitone and QC-20. The addition of glass fiber does not increase significantly the microhardness in the groups. With respect to flexural strength glass fiber particulate significantly increased all values, as well as the modulus of acrylic resin reinforced by the addition of glass fibers.
39

Caracterização da relaxação por compressão de borracha acrílica irradiada. / Compression relaxation characterization of irradiated acrylic rubber.

Santos, Demetrio Jackson dos 11 February 2011 (has links)
Este trabalho tem como objetivo investigar a redução da relaxação por compressão de borracha acrílica modificada (ACM) irradiada por feixe de elétrons, através da caracterização de seu comportamento mecânico e de sua estrutura molecular. O material, nas condições original e irradiado, foi inicialmente submetido a ensaios uniaxiais de tração e espectroscopia por infravermelho com o objetivo de verificar a influência da irradiação EB em seu comportamento, eliminando a possibilidade de degradação do material, permitindo a continuidade dos estudos. Definidas as doses, novos corpos de prova foram irradiados e submetidos a ensaios uniaxiais, equibiaxiais de tensão e cisalhamento puro, gerando resultados que foram aplicados na simulação pelo método de elementos finitos, utilizando o modelo de comportamento elástico não-linear de Ogden, para predizer o comportamento do material em condições de compressão. Confirmado o aumento da tensão por compressão para mesmas deformações, com o aumento da dose de radiação, análises termogravimétricas e dinâmicas mecânicas foram realizadas para possibilitar o entendimento do fenômeno. Na fase final do trabalho ensaios de relaxação por compressão foram realizados, em diferentes níveis de deformação e temperatura, apresentando a redução da relaxação por compressão gerada pela radiação EB e quantificando tal influência combinada com outros fatores, através da aplicação dos resultados no método de Planejamento Fatorial 2k. / The aim of this work is to investigate the compression stress relaxation (CSR) decrease of modified acrylic rubber, irradiated by electron beam, through its mechanical behavior and molecular structure characterization. Uniaxial tensile test and infrared spectroscopy were carried out, on original and irradiated material conditions, to verify the influence of EB irradiation on ACM, and to eliminate the possibility of degradation caused by EB radiation. After to define the radiation doses, new ACM specimens were irradiated. Uniaxial, equibiaxial and planar shear tests generated experimental data, which were applied to simulate the non linear elastic behavior of the material, through finite elements method, using the Ogden Model. Confirmed the compression stress increase at same deformation level, caused by increasing of radiation dose, thermogravimetric and dynamic mechanical analysis were carried out in order to make possible to understand the behavior changes. In the final part of this work, compression stress relaxation experiments were carried out, at two deformation and temperature levels, with the purpose to validate the compression stress relaxation decrease caused by EB radiation, and to quantify such influence combined with other factors. The CSR decrease combined with other influence variables were studied through use of factorial design.
40

Avaliação da cor, corrosão e rugosidade superficial do titânio c.p., ligas metálicas e resina acrílica termopolimerizável sob a ação de soluções higienizadoras / Color, corrosion and surface roughness evaluation of titanium c.p., alloys and heat-polymerized acrylic resin under the action of daily hygiene solutions

Letícia Resende Davi 03 May 2010 (has links)
A higienização das próteses parciais ou totais removíveis é fundamental para a durabilidade do tratamento e prevenção de patologias orais. O objetivo deste estudo foi avaliar o efeito de agentes higienizadores de prótese na cor, corrosão e rugosidade superficial do titânio c.p., ligas metálicas e resina acrílica termopolimerizável, simulando um período de 180 dias de higienização. Espécimes em formato de discos (12 mm x 3 mm) foram confeccionados em: titânio comercialmente puro (Tritan - Ti c.p.), liga de níquel-cromo-molibdênio-titânio (Vi-Star), liga de níquel-cromo (Fit Cast-SB Plus) e liga de níquel-cromo-berílio (Fit Cast-V). Cada disco fundido foi incluído em mufla previamente preparada por matrizes retangulares de teflon (38 mm x 18 mm x 4 mm), incorporando-se o disco metálico à resina acrílica termopolimerizável. Os corpos-de-prova (n=5) foram imersos em soluções dos agentes higienizadores: hipoclorito de sódio a 0,05%, Periogard, Cepacol, pastilha Corega Tabs, pastilha Medical Interporous e pastilha Polident 3 Minute. Como controle, foi utilizada a água deionizada. Foram realizados ensaios de estabilidade de cor por meio de espectrocolorímetro (Color-guide 45/0), resistência à corrosão por meio da análise visual da presença de manchas no metal e análise da alteração de massa (balança eletrônica analítica), e rugosidade superficial por meio de rugosímetro (Surftest SJ-201P). Além disso, foi realizada análise quantitativa de liberação de íons metálicos por meio de espectrometria de massa com plasma indutivamente acoplado (ICP-MS - ELAN DRC II). Os resultados de estabilidade de cor, alteração de massa e rugosidade foram submetidos à ANOVA e teste de Tukey (p< 0,05). Quanto à estabilidade de cor da resina acrílica termopolimerizável (E), houve diferença estatisticamente significante entre o titânio c.p. e as ligas. A resina associada ao Ti c.p. apresentou menor alteração de cor, enquanto que a resina associada à Fit Cast-SB Plus apresentou a maior alteração de cor (1,33 ± 1,11 e 5,06 ± 1,96, respectivamente). Com relação à presença de manchas no metal, o hipoclorito de sódio causou manchamento nos espécimes das ligas Vi-Star e Fit Cast-V. Quando avaliada a alteração de massa (g), o Cepacol e a pastilha Corega Tabs propiciaram maior perda de massa. Entre os metais, a amostra do Ti c.p. apresentou maior perda de massa. Quanto à rugosidade (Ra, µm) da resina, o Cepacol causou maior rugosidade, enquanto que a pastilha Corega Tabs e o Periogard propiciaram maior lisura no corpo-de-prova. A resina associada ao Ti c.p. e ao Fit Cast-SB Plus apresentaram maior rugosidade. Quanto à rugosidade do metal, os produtos de imersão não influenciaram nos resultados, mas a liga Fit Cast-SB Plus apresentou maior rugosidade após a imersão. A liberação de íons mais expressiva foi constatada nas ligas Vi-Star e Fit Cast-V após a imersão na pastilha Medical Interporous. Pode-se concluir que as ligas Vi-Star e Fit Cast-V podem ser consideradas seguras para a confecção de aparelhos protéticos removíveis, mas com a condição de não utilizar o hipoclorito de sódio a 0,05% ou a pastilha Medical Interporous para a higienização, pois causaram corrosão e maior liberação de íons, respectivamente. / The hygiene care of the removable partial and complete dentures is required for the longevity of the treatment and prevention of oral diseases. The aim of this study was to evaluate the effect of denture cleansers on color, corrosion and surface roughness of the commercially pure titanium, metal alloys and heat-polymerized acrylic resin, simulating a period of 180 days of hygiene. Disk-shaped specimens (12 mm x 3 mm) had been fabricated with commercially pure titanium (Tritan - Ti c.p.), nickel-chromium-molybdenum-titanium alloy (Vi-Star), nickel-chromium alloy (Fit Cast-SB Plus) and nickel-chromium-beryllium alloy (Fit Cast-V). Each cast disc was invested in the flasks previously prepared by Teflon rectangular matrices (38 mm x 18 mm x 4 mm), incorporating the metal disk to the heat-polymerized acrylic resin. The specimens (n= 5) had been immersed in the solutions: sodium hypochlorite 0.05%, Periogard, Cepacol, Corega Tabs, Medical Interporous and Polident 3 Minute. As a control, it was used deionized water. It was accomplished assays of color stability by means of a colorimeter (Color-guide 45/0), corrosion resistance by means of visual analysis of tarnishes on the metal and mass alteration analysis (analytical electronic balance), and surface roughness by means of a surface analyzer (Surftest SJ-201P). Besides, the quantitative analysis of metal ions release was accomplished by means of inductively coupled plasma mass spectrometry (ICP-MS - ELAN DRC II). Color stability, mass alteration and roughness results were submitted to ANOVA and Tukey test (p<0.05). Considering the color stability of the heat-polymerized acrylic resin (E), there were statistically significant difference between the titanium c.p. and the alloys. The resin associated with the Ti c.p. showed lesser color alteration, whereas the resin associated with Fit Cast-SB Plus showed the higher color alteration (1,33 ± 1,11 e 5,06 ± 1,96, respectively). In relation to the presence of tarnishes on the metals, the sodium hypochlorite caused tarnishes on specimens of the Vi-Star and Fit Cast-V alloys. When evaluated the mass alteration (g), Cepacol and Corega Tabs propitiated higher weight loss. Between the metals, the Ti c.p. samples showed greater weight loss. Considering the resin roughness (Ra, µm), Cepacol caused higher roughness, whereas Corega Tabs and Periogard propitiated greater smoothness on the specimens. The resin associated with the Ti c.p. and Fit Cast-SB Plus showed higher roughness. Considering the metal roughness, the immersion products did not influence on the results, but the Fit Cast-SB Plus showed greater roughness after immersion. The ionic release most significant was with the Vi-Star and Fit Cast-V alloys after immersion in Medical Interporous. It could be concluded that the Vi-Star and Fit Cast-V alloys can be considered safe for removable prosthesis finish, but with the condition of do not use sodium hypochlorite 0.05% or Medical Interporous tablet for hygiene, because they caused corrosion and greater ionic release, respectively.

Page generated in 0.1007 seconds