• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 32
  • Tagged with
  • 32
  • 32
  • 32
  • 22
  • 21
  • 16
  • 14
  • 10
  • 8
  • 8
  • 6
  • 6
  • 5
  • 5
  • 4
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
21

Miringotomia pelo método de microeletrocautério por radiofreqüência associado à mitomicina C em modelo animal

Faccini, Vanessa Chisté Guimarães January 2007 (has links)
Introdução: Este presente estudo tem como objetivo descrever uma técnica cirúrgica alternativa à inserção do tubo de ventilação na membrana timpânica: a miringotomia por radiofreqüência isolada e associada à mitomicina C. Ressaltando-se, então, a importância de um método cirúrgico que proporcione uma execução mais simples, sem necessidade de anestesia geral, e não sujeito às complicações vinculadas ao tubo de ventilação. Método: Estudo experimental randomizado e comparado, em ratos da linhagem Wistar. Foram comparadas as técnicas de miringotomia por microlanceta e por microeletrocautério por radiofreqüência (ponteira 0,3 mm e 0,7 mm) isolada e associada à mitomicina C, considerando o tempo de fechamento timpânico. Resultados: Houve uma diferença estatisticamente significante entre a miringotomia por radiofreqüência e por microlanceta. Ao analisar a técnica por radiofreqüência com ponteira 0,7 mm associada à mitomicina C (teste de Wilcoxon), o P encontrado foi menor que 0,001, demonstrando uma significância estatística. O tempo máximo de fechamento foi de 44 dias e a mediana encontrada foi de 14 dias. Conclusão: A miringotomia por radiofreqüência apresenta uma patência mais prologada que a microlanceta. Ao associar a técnica de radiofreqüência com ponteira de maior diâmetro (0,7 mm) à mitomicina C há uma otimização no tempo de cicatrização da miringotomia. / Introduction. The present study describes the myringotomy by radiofrequency, isolated or associated to mitomycin C, an alternative surgical technique to the insertion of a ventilation tube through the tympanic membrane, and emphasizes the value of this easier surgical procedure requiring no general anesthesia and avoiding the complications that can occur with the ventilation tube. Method. Randomized and compared study in Wistar rats. The time elapsed for tympanic membrane recovery was compared between the myringotomy with microlancet and the myringotomy by radiofrequency (0.3mm and 0.7mm tip) isolated or associated to mitomycin C. Results. There was a statistically significant difference between the procedures. Analysis (Wilcoxon Test) of the myringotomy with 0.7mm tip radiofrequency associated to mitomycin C revealed P <0,001. The longest time for membrane recovery was 44 days with a mean of 14 days. Conclusion. Myringotomy by radiofrequency lasts longer than myringotomy with microlancet. The association of the radiofrequency with 0.7mm tip to mitomycin C enhances the patency of the myringotomy.
22

Análise espectral de sinais atriais e sua correlação topográfica com a inervação parassimpática cardíaca / Spectral analysis of atrial signals and its topographic correlation with cardiac parassimpathetic innervation

Esteban Wisnivesky Rocca Rivarola 22 August 2011 (has links)
Objetivo. Verificar se as características espectrais dos eletrogramas atriais (EgA) em ritmo sinusal (RS) se correlacionam com a presença de gânglios parassimpáticos cardíacos. Materiais e Resultados. Treze pacientes encaminhados para submeter-se a ablação de fibrilação atrial (FA) foram incluídos de forma prospectiva. Previamente ao início da ablação, realizou-se o registro de EgA em RS em uma série de regiões anatômicas pré-determinadas, seguindo-se uma ordem sequencial. Em seguida, aplicou-se estímulos elétricos de alta frequência (20 Hz de frequência, amplitude de 100 V e duração de pulso de 4 ms), nos mesmos locais. Uma resposta vagal evocada foi definida como um súbito aumento no intervalo RR ou a indução de bloqueio na condução átrio-ventricular imediatamente após a aplicação do estímulo de alta-frequência (EAF). Procedeu-se à análise espectral dos sinais atriais em RS registrados, com amostragem de 1000 Hz, janela Hanning. No total, 1488 EgA oriundos de 186 locais anatômicos foram registrados, sendo 129 de regiões com resposta vagal negativa e 57 correspondentes a regiões de resposta vagal positiva. A duração do eletrograma e o número de deflecções foram similares nos pontos com resposta vagal positiva e negativa. A densidade de potência espectral em locais de resposta vagal positiva, no entanto, foi menor entre 26 e 83 Hz, e maior entre 107 e 200 Hz, comparados com os locais de resposta negativa. A área sobre a curva entre 120 e 170 Hz normalizada para a área total do espectro foi testada como um novo parâmetro diagnóstico. A análise de curva ROC demonstrou que o valor area 120-170 / area total > 0,14 foi capaz de identificar locais de inervação vagal com sensibilidade de 70,9% e especificidade de 72,1%. Conclusão. A análise espectral de sinais atriais durante RS é um método factível e simples de mapear os locais de inervação parassimpática cardíaca, sem a necessidade de qualquer tipo de estimulação / Objective. To verify whether spectral components of atrial electrograms (AE) during sinus rhythm (SR) correlate with cardiac ganglionated plexus (GP) sites. Methods and Results. Thirteen patients undergoing atrial fibrillation (AF) ablation were prospectively enrolled. Prior to radio frequency application, endocardial AE were recorded with a sequential point-by-point approach. Electrical stimuli were delivered at 20 Hz, amplitude 100 V, and pulse width of 4 msec. A vagal response was defined as a high-frequency stimulation (HFS) evoked AV block or a prolongation of RR interval. Spectral analysis was performed on single AE during SR, sampling rate of 1000 Hz, Hanning window. Overall, 1488 SR electrograms were analyzed from 186 different left atrium sites, 129 of them corresponding to negative vagal response sites and 57 to positive response sites. The electrogram duration and the number of deflections were similar in positive and negative response sites. Spectral power density of sites with vagal response was lower between 26 and 83 Hz and higher between 107 and 200 Hz compared with negative response sites. The area between 120 and 170 Hz normalized to the total spectrum area was tested as a diagnostic parameter. ROC curve analysis demonstrated that an area 120-170 / area total value > 0,14 identified vagal sites with 70,9% sensitivity and 72,1% specificity. Conclusions. Spectral analysis of AE during SR is feasible and simple method of mapping the cardiac autonomic nervous system (ANS), with no stimulation required
23

Análise do efeito do resfriamento da via excretora durante termoablação com radiofreqüência em rim de porco / Analysis of the cooling effect in the urinary system during renal radiofrequency thermoablation in pigs

André Meirelles dos Santos 29 April 2005 (has links)
A ablação de tumores renais com radiofreqüência tem se tornado uma alternativa cada vez mais atraente dentro do arsenal de procedimentos minimamente invasivos. Uma das raras complicações desta forma de tratamento é a lesão térmica do urotélio, desencadeando fístulas urinárias, hidronefrose, estenose ureteral e estenose de junção ureteropiélica, em alguns casos, com necessidade de nefrectomia do órgão acometido. Em lesões hepáticas, ablação tumoral muito perto da via biliar pode evoluir com estenose, a menos que haja um resfriamento dos dutos biliares concomitante à aplicação da radiofreqüência. Desta forma, o objetivo deste estudo foi o de propor um processo semelhante no trato urinário, comparando ablações renais próximas ao urotélio, com e sem irrigação do sistema coletor, com soro fisiológico a 2°C, analisando a integridade da via excretora e a eficácia da ablação. Métodos: Oito suínos do sexo feminino foram submetidos à laparotomia, com abertura da bexiga e cateterização de um dos meatos ureterais com cateter de duplo-lúmen, conforme sorteio realizado antes do início do procedimento. Foi realizada aplicação de radiofreqüência com um ciclo de oito minutos, regulada para atingir uma temperatura média de 100°C e aplicada com uma agulha deflagrada com um centímetro de exposição, sendo produzida uma lesão superficial no terço médio do rim. O grau de profundidade da agulha foi monitorado pelo uso de ultra-som intra-operatório. No total, foram realizadas duas lesões em cada animal, uma no rim sem cateter ureteral, e outra em um rim exposto ao resfriamento da via excretora com soro fisiológico a 2°C, circulando a 30 ml/min. Os animais foram sacrificados no décimo-quarto dia de pósoperatório. Resultados: Os maiores diâmetros da lesão criada pela radiofreqüência e o aspecto radiológico da via excretora, obtido por meio de pielografia ascendente bilateral, foram comparados e não houve diferença significativa entre os rins tratados, estando ou não expostos ao resfriamento da via excretora. Conclusão: O resfriamento da via excretora durante ablação com radiofreqüência não alterou a necrose de coagulação gerada, tampouco afetou a integridade da via excretora / Renal tumor ablation has become quite an attractive alternative among minimally invasive procedures. One of the few complications of this new technology is thermal damage to the urothelium, causing urinary fistula, hydronephrosis and ureteral and ureteropelvic junction obstruction. Some cases required a nephrectomy. In hepatic lesions, tumoral ablation near biliary ducts may cause stenosis, unless intraductal cooling of the main ducts is done simultaneously with radiofrequency ablation. This study proposed using a similar process in the urinary tract, comparing renal ablation near the urothelium, with and without cooling the collecting system with 2°C 0.9% saline, and analyzing the excretory ducts\' integrity and the ablation efficiency. Methods: Eight female porcines were submitted to laparotomy and bladder opening, having one of the ureteral meatus catheterized with a double-lumen catheter according to a random selection made prior to the procedure. An eight minute radiofrequency cycle, planned to achieve a mean temperature of 100°C, was done using a needle with one centimeter of exposition, creating a superficial lesion in the renal cortex. The needle depth was monitored by ultrasound during surgery. Two lesions were made in each animal, one in a kidney without a catheter and the other in a kidney cooled with 2°C 0.9% saline circulating at 30 ml/ min. The pigs were put to death two weeks after the procedure. Results: The largest diameters were determined for each lesion and bilateral retrograde pielography was done to check the radiological aspect of the urinary ducts. No significant difference between the kidneys was observed, regardless of whether the urinary system had been cooled or not. Conclusion: Cooling the excretory ducts during radiofrequency ablation did not alter the coagulation necrosis, nor did it affect the integrity of the urinary collecting system.
24

Estudo randomizado duplo-cego comparativo entre eletrocoagulação e radiofrequência no tratamento de pacientes portadores de insuficiência de veia safena magna e varizes dos membros inferiores / Prospective, double-blind, randomized controlled trial comparing electrocoagulation and radiofrequency in the treatment of patients with great saphenous vein insufficiency and lower limb varicose veins

Camila Baumann Beteli 22 November 2017 (has links)
Introdução: A termoablação vem substituindo a cirurgia convencional no tratamento cirúrgico do refluxo da veia safena magna em pacientes portadores de varizes dos membros inferiores. Contudo, a termoablação apresenta elevados custos. A Eletrocoagulação endovenosa pode, seletivamente e de forma segura, causar necrose da parede da veia safena magna, mas seus resultados clínicos nunca foram estudados previamente. O objetivo deste estudo é comparar a Eletrocoagulação e a Radiofrequência no tratamento da insuficiência da veia safena magna, considerando eficácia, complicações e impacto na qualidade de vida. Métodos: Trata-se de um ensaio clinico prospectivo, randomizado e duplo-cego. Os pacientes portadores de varizes de membros inferiores e refluxo de veia safena magna ao Eco Doppler colorido foram randomizados em dois grupos de tratamento: Eletrocoagulação ou Radiofrequência. O seguimento dos pacientes ocorreu após uma semana, três meses e seis meses do procedimento. O desfecho primário foi considerado como oclusão da veia safena magna ao Eco Doppler colorido e o desfecho secundário, como a taxa de complicações e a melhora na qualidade de vida, mediante pontuação do Escore de Gravidade Clínica Venosa e Questionário Aberdeen para Veias Varicosas. Resultados: Foram incluídos no estudo 57 pacientes, totalizando 85 veias safenas magnas tratadas, sendo que 43 foram submetidas à Radiofrequência e 42, à Eletrocoagulação. Não houve diferença estatisticamente significante entre os grupos, no pré-operatório, em relação à idade (P = 0,264), gênero (P = 0,612), Escore de Gravidade Clínica Venosa (P = 0,125), Questionário Aberdeen para Veias Varicosas (P = 0,054), diâmetro (P = 0,880) e profundidade (P = 0,763) da veia safena magna tratada. No intraoperatório, imediatamente após a realização da termoablação, todas as veias safenas magnas submetidas à eletrocoagulação apresentaram ausência de fluxo no segmento tratado e incompressibilidade, enquanto 12 membros ainda exibiam fluxo em sua veia safena magna tratada (P < 0,001) e 9 veias apresentavam-se compressíveis (P < 0,001), quando submetidas à Radiofrequência. A principal complicação pós-operatória encontrada foi a parestesia, não havendo significância estatística quanto à sua presença entre os grupos (P = 0,320). O tempo de retorno às atividades rotineiras foi menor no grupo da Eletrocoagulação em relação ao grupo da Radiofrequência (P = 0,026). Não houve diferença entre os grupos em relação à taxa de oclusão da veia safena magna no seguimento de 3 meses (P = 0,157) e 6 meses (P = 0,157), bem como na melhora da pontuação do Questionário Aberdeen para veias varicosas após 3 meses (P = 0,786) e 6 meses (P = 0,401) e na melhora da pontuação do Escore de Gravidade Clínica Venosa após 3 meses (P = 0,324) e 6 meses (P = 0,367). Conclusões: A Eletrocoagulação revelou-se um método eficaz para ablação da veia safena magna, com taxa de oclusão venosa, ocorrência de complicações e impacto na qualidade de vida semelhantes àqueles encontrados na Radiofrequência. / Background: Thermoablation has been replacing conventional surgery in the surgical treatment of great saphenous vein reflux in patients with lower limb varicose veins; however, thermoablation is expensive. Intravenous Electrocoagulation may, selectively and safely, cause necrosis of the great saphenous vein wall, but the clinical results have never been studied. The objective of this study was to compare Electrocoagulation and Radiofrequency in the treatment of great saphenous vein insufficiency, considering efficacy, complications and effect on quality of life. Methods: This is a prospective, double-blind, randomized clinical trial. Patients with lower limb varicose veins and great saphenous vein reflux confirmed by duplex ultrasonography were randomized into two treatment groups: Electrocoagulation or Radiofrequency. Patients were followed-up 1 week, 3 months and 6 months after the procedure. Occlusion of the great saphenous vein confirmed by duplex ultrasonography was considered the primary outcome and the rate of complications and improvement in quality of life, using the Aberdeen Varicose Veins Questionnaire and Venous Clinical Severity Score, were the secondary outcome. Results: Fifty-seven patients were included, with a total of 85 treated great saphenous veins; 43 were treated with Radiofrequency and 42 with Electrocoagulation. There was no statistically significant difference between the groups regarding age (P = 0,264), sex (P = 0,612), Venous Clinical Severity Score (P = 0,125), Aberdeen Varicose Veins Questionnaire score (P = 0,054), diameter (P = 0,880) and depth (P = 0,763) of the treated great saphenous vein. In the intraoperative period, immediately after thermoablation, all great saphenous veins treated with Electrocoagulation presented no flow in the treated segment and incompressibility, while 12 limbs still had flow in treated great saphenous vein (P < 0,001), and 9 veins showed compressibility (P < 0,001) when treated with Radiofrequency. The main postoperative complication was paresthesia; however there was no statistical significance between the groups (P = 0,320) regarding its presence. Time to return to routine activities was lower in the Electrocoagulation group than in the Radiofrequency group (P = 0,026). There was no difference between the groups at the 3-month (P = 0,157) and 6-month (P = 0,157) follow-ups regarding occlusion of the great saphenous vein and in improvement of Aberdeen Varicose Veins Questionnaire score after 3 months (P = 0,786) and 6 months (P = 0,401) and Venous Clinical Severity Score after 3 months (P = 0,324) and 6 months (P = 0,367). Conclusions: Electrocoagulation has been shown to be an effective method for ablation of the great saphenous vein, with venous occlusion rate, occurrence of complications, and effect on the quality of life similar to that with Radiofrequency.
25

Ablação por radiofreqüência da fibrilação atrial paroxística: fatores determinantes da eficácia clínica a longo prazo / Radiofrequency catheter ablation of paroxysmal atrial fibrillation: decisive factors of the clinical efficacy in long-term.

Raul José Pádua Sartini 30 May 2007 (has links)
O objetivo deste estudo foi avaliar retrospectivamente, em longo-prazo, os preditores de recorrência de fibrilação atrial paroxística (FA) em 139 pacientes submetidos à ablação por radiofreqüência, através das técnicas ostial ou extraostial de abordagem do átrio esquerdo, associadas ou não à ablação do istmo cavo-tricuspídeo (ICT). Variáveis pré, intra e pós-ablação foram avaliadas por análise uni e multivariada, para determinar os preditores de recorrência da FA após um procedimento. Observou-se que maior tempo de história de FA, uso de mais antiarrítmicos e recorrência de FA dentro de 60 dias pós-procedimento, aumentaram o risco de recorrência de FA a longo-prazo. Por outro lado, a associação de flutter atrial e a ablação concomitante do ICT, reduziram o risco de recorrência ao final de 33 ±12 meses. / The objective of this study was to evaluate in retrospect, in long-term, the predictors of late recurrence of atrial fibrillation (AF) in 139 patients submitted to the ablation by radiofrequency, through the techniques ostial or extra-ostial of approach of the atrium left, associated or not to the ablation of the cavotricuspid isthmus(ICT). Variables pre, intra and post-ablation were appraised for analysis uni and multivariated, to determine the predictors of recurrence of AF after one procedure. It was observed that larger time of history of AF, use of more drugs and recurrence of AF within 60 days after procedure; they increased the risk of recurrence of AF in long-term. On the other hand, the association of atrial flutter and the concomitant ablation of ICT, they reduced the recurrence risk at the end of 33 ±12 months.
26

Ablação do istmo cavo-tricuspídeo para controle do flutter atrial: estudo prospectivo e randomizado comparando eficácia e segurança de cateter irrigado com cateter de 8 mm. / Cavotricuspid isthmus ablation for the treatment of atrial flutter: prospective randomized study comparing efficacy and safety of cooled-tip versus 8-mm-tip catheters.

Melo, Sissy Lara 21 February 2005 (has links)
O cateter irrigado foi comparado com o de 8 mm para ablação com radiofrequência do istmo cavo-tricuspídeo(Ist-CT). Foram randomizados 52 pacientes portadores de flutter atrial típico para ablação com cateter irrigado(grupoI) ou com cateter de 8 mm(grupo II). O bloqueio do Ist-CT foi obtido em 51 pacientes. Não houve diferença estatística em relação aos parâmetros de aplicação de RF entre os dois grupos. A ablação do Ist-CT com cateter irrigado versus cateter de 8mm foi igualmente eficaz e segura no controle do flutter atrial típico. / A 4-mm cooled tip catheter was compared to an 8-mm tip catheter to cavotricuspid isthmus(CTI) ablation. This prospective study enrolled 52 patients with typical atrial flutter to ablation with a closed cooled-tip catheter(group1) or an 8-mm tip catheter. Radiofrequency(RF) applications were performed to achieve complete CTI block wich was achieved in 51 patients. No significant differences were found in the procedure parameters. CTI ablation with an irrigated tip catheter versus an 8-mm tip catheter was equally effective and satisfactorily safe for ablation of typical atrial flutter.
27

Estudo prospectivo e randomizado para avaliar a eficácia e segurança da ablação epicárdica de taquicardia ventricular utilizando cateter irrigado com sensor de contato / Efficacy and safety of epicardial vt ablation using contact force irrigated tip catheter in Chagas disease

Pisani, Cristiano Faria 20 February 2019 (has links)
Introdução: O mapeamento e ablação epicárdico é frequentemente necessário em pacientes com cardiopatia não-isquêmica, especialmente pacientes com doença de Chagas. Entretanto, não existem estudos randomizados provando a sua superioridade em comparação a ablação endocárdica exclusiva. Métodos: Foram selecionados 30 pacientes com doença de Chagas encaminhados para ablação de TV sendo randomizados para (1) ablação endocárdica exclusiva e (2) ablação endo e epicárdica combinada. No grupo combinado a ablação era realizada na superfície que se observava os melhores sinais durante TV ou mapeamento de substrato. No grupo endocárdico exclusivo, a ablação era realizada inicialmente na superfície endocárdica apenas e se não existisse cicatriz ou a TV clínica se mantivesse indutível ocorria a continuação da ablação. O objetivo eficácia foi a não reindutibilidade da TV e segurança foi a taxa de complicações do procedimento. Resultados: A maioria dos pacientes eram do sexo masculino, com idade mediana de 67 (58;70) e 58 (43; 66) anos e FEVE de 31,1 ± 11,5% and 41,0 ± 17%, respectivamente. Ocorreu significativamente menos falhas da ablação no grupo combinado (2/15) em comparação ao grupo endocárcico exclusivo (9/126; P=0,21). A ablação epicárdica foi também realizada em nove pacientes do grupo endocárdico exclusivo devido a ausência de cicatriz endocárdica e manutenção da indutibilidade da TV. Não se observou complicações relacionadas ao procedimento. Conclusão: Neste estudo randomizado de ablação epicárdica e endocárdica de TV em pacientes com Doença de Chagas, ocorreu menos insucesso na ablação quando a estratégia combinada endo e epicárdico foi utilizada. Ambas estratégias foram seguras / Background: Epicardial mapping and ablation are frequently necessary for nonischemic cardiomyopathy, especially in Chagas disease patients. We developed this randomized trial to evaluate the efficacy and safety of combined epicardial ablation in Chagas disease patients. Methods: We randomized 30 patients with Chagas disease into an endocardial-only group or a combined epi and endocardial mapping and ablation group. In the combined group, ablation was performed on the surface with optimal signals during mapping. In the endo-only group, ablation was initially performed only on the endo surface despite of nonoptimal signals. The endpoint was efficacy, measured by ventricular tachycardia reinducibility and safety measured by the rate of complications. For endo-only patients, epicardial ablation continuation was allowed after inducibility was assessed following ablation. Results: Most of the patients were male, the median age was 67 (58; 70) and 58 (43; 66) years-old and LVEF was 31.1 ± 11.5% and 41.0 ± 17%, respectively. There was a significant fewer failure for the combined group (2 in 15 patients) comparing to endo only-group ablation (9/15 patients;P=0,021). Epicardial ablation was also performed in nine patients in the endo group after ablation failure due to an absence of endocardial scar and maintenance of VT inducibity. There were no complications related to the epicardial access or ablation. Conclusions: In this randomized trial of epicardial and endocardial VT ablation in Chagas disease, there was less failure of ablation when a combined endo/epi approach was used. Both approaches were safe
28

Ablação do istmo cavo-tricuspídeo para controle do flutter atrial: estudo prospectivo e randomizado comparando eficácia e segurança de cateter irrigado com cateter de 8 mm. / Cavotricuspid isthmus ablation for the treatment of atrial flutter: prospective randomized study comparing efficacy and safety of cooled-tip versus 8-mm-tip catheters.

Sissy Lara Melo 21 February 2005 (has links)
O cateter irrigado foi comparado com o de 8 mm para ablação com radiofrequência do istmo cavo-tricuspídeo(Ist-CT). Foram randomizados 52 pacientes portadores de flutter atrial típico para ablação com cateter irrigado(grupoI) ou com cateter de 8 mm(grupo II). O bloqueio do Ist-CT foi obtido em 51 pacientes. Não houve diferença estatística em relação aos parâmetros de aplicação de RF entre os dois grupos. A ablação do Ist-CT com cateter irrigado versus cateter de 8mm foi igualmente eficaz e segura no controle do flutter atrial típico. / A 4-mm cooled tip catheter was compared to an 8-mm tip catheter to cavotricuspid isthmus(CTI) ablation. This prospective study enrolled 52 patients with typical atrial flutter to ablation with a closed cooled-tip catheter(group1) or an 8-mm tip catheter. Radiofrequency(RF) applications were performed to achieve complete CTI block wich was achieved in 51 patients. No significant differences were found in the procedure parameters. CTI ablation with an irrigated tip catheter versus an 8-mm tip catheter was equally effective and satisfactorily safe for ablation of typical atrial flutter.
29

Avaliação da viabilidade da técnica de acesso ao espaço epicárdico por punção transatrial para ablação epicárdica por catete / Percutaneous transatrial approach to reach the epicardial space for epicardial mapping and ablation

Venancio, Ana Claudia 20 January 2011 (has links)
Fundamentos O acesso percutâneo ao espaço pericárdico pela via transatrial poderia ser uma alternativa ao acesso subxifóide para o mapeamento e ablação de fibras miocárdicas subepicárdicas. O objetivo deste estudo foi avaliar a viabilidade de alcançar o espaço pericárdico normal através do apêndice auricular direito (AAD) por acesso transvenoso. Métodos e Resultados - Um sistema Mullins (8F), originalmente desenvolvido para alcançar o átrio esquerdo (AE) por punção transeptal foi utilizado neste estudo para transfixar o AAD (16) ou AE (1) em 17 suínos, com uma média de 26,9 ± 2,6 kg, e alcançar o espaço pericárdico normal. Um cateter 7F quadripolar com eletrodo distal com 4 ou 8 mm foi introduzido no espaço pericárdico para aplicações de radiofrequência. Em 15 (88%) animais o procedimento foi realizado sem instabilidade hemodinâmica (PA média inicial = 80,4 ± 11.7 mmHg; PA média final = 86,8 ± 9.7 mmHg, p = 0,11). Foi identificado e aspirado derrame pericárdico discreto (28,9 ± 27.6 ml/animal) durante o procedimento. O espaço pericárdico foi acidentalmente acessado por punção do ventrículo direito (VD) em um animal e por punção do anel da valva tricúspide em outro. Ambos apresentaram sangramento xii pericárdico importante e tamponamento cardíaco. Um dispositivo para oclusão do orifício de perfuração foi testado com sucesso em três porcos, dois no AD e um no VD, sem ocorrência de derrame pericárdico significativo. Conclusões O acesso transatrial ao espaço pericárdico pode ser potencialmente útil para mapeamento e ablação de arritmias cardíacas, bem como para drenagem imediata de um tamponamento cardíaco agudo / Background A transvenous access to the pericardial space could provide a convenient route to map and ablate subepicardial myocardial fibers. The aim of this study was to evaluate the feasibility of reaching the normal pericardial space through the right atrial appendage (RAA) by transvenous access. Methods and Results An 8F Mullins system was used to transfix the right atrium (16) and left atrium (1) in 17 pigs with a mean of 26.9 ± 2.6 kg. A 7F quadripolar catheter with 4 or 8 mm distal tip electrode was introduced into the pericardial space to perform epicardial radiofrequency lesions. The pericardial space was successfully reached in 15 (88%) animals without hemodynamic instability (initial mean BP 80.4 ± 11.7 mmHg; final 86.8 ± 9.7 mmHg, p= 0,11). However, a mild pericardial serohemorrhagic effusion was identified and aspirated in all the animals (28.9 ± 27.6 ml/pig) during the procedure. The pericardial space was accidentally accessed through the right ventricle (RV) in one animal and through the tricuspid annulus in another, which presented important pericardial bleeding and cardiac tamponade. The hypothesis that an occlusion device could be useful to close the created atrial xiv orifice was tested successfully in thee pigs (two at RAA and one at RV) and without significant pericardial bleeding. Conclusions The right atrial appendage route might be potentially useful to access the normal pericardial space for mapping and ablating cardiac arrhythmias as well as to drain promptly an acute tamponade
30

Avaliação da viabilidade da técnica de acesso ao espaço epicárdico por punção transatrial para ablação epicárdica por catete / Percutaneous transatrial approach to reach the epicardial space for epicardial mapping and ablation

Ana Claudia Venancio 20 January 2011 (has links)
Fundamentos O acesso percutâneo ao espaço pericárdico pela via transatrial poderia ser uma alternativa ao acesso subxifóide para o mapeamento e ablação de fibras miocárdicas subepicárdicas. O objetivo deste estudo foi avaliar a viabilidade de alcançar o espaço pericárdico normal através do apêndice auricular direito (AAD) por acesso transvenoso. Métodos e Resultados - Um sistema Mullins (8F), originalmente desenvolvido para alcançar o átrio esquerdo (AE) por punção transeptal foi utilizado neste estudo para transfixar o AAD (16) ou AE (1) em 17 suínos, com uma média de 26,9 ± 2,6 kg, e alcançar o espaço pericárdico normal. Um cateter 7F quadripolar com eletrodo distal com 4 ou 8 mm foi introduzido no espaço pericárdico para aplicações de radiofrequência. Em 15 (88%) animais o procedimento foi realizado sem instabilidade hemodinâmica (PA média inicial = 80,4 ± 11.7 mmHg; PA média final = 86,8 ± 9.7 mmHg, p = 0,11). Foi identificado e aspirado derrame pericárdico discreto (28,9 ± 27.6 ml/animal) durante o procedimento. O espaço pericárdico foi acidentalmente acessado por punção do ventrículo direito (VD) em um animal e por punção do anel da valva tricúspide em outro. Ambos apresentaram sangramento xii pericárdico importante e tamponamento cardíaco. Um dispositivo para oclusão do orifício de perfuração foi testado com sucesso em três porcos, dois no AD e um no VD, sem ocorrência de derrame pericárdico significativo. Conclusões O acesso transatrial ao espaço pericárdico pode ser potencialmente útil para mapeamento e ablação de arritmias cardíacas, bem como para drenagem imediata de um tamponamento cardíaco agudo / Background A transvenous access to the pericardial space could provide a convenient route to map and ablate subepicardial myocardial fibers. The aim of this study was to evaluate the feasibility of reaching the normal pericardial space through the right atrial appendage (RAA) by transvenous access. Methods and Results An 8F Mullins system was used to transfix the right atrium (16) and left atrium (1) in 17 pigs with a mean of 26.9 ± 2.6 kg. A 7F quadripolar catheter with 4 or 8 mm distal tip electrode was introduced into the pericardial space to perform epicardial radiofrequency lesions. The pericardial space was successfully reached in 15 (88%) animals without hemodynamic instability (initial mean BP 80.4 ± 11.7 mmHg; final 86.8 ± 9.7 mmHg, p= 0,11). However, a mild pericardial serohemorrhagic effusion was identified and aspirated in all the animals (28.9 ± 27.6 ml/pig) during the procedure. The pericardial space was accidentally accessed through the right ventricle (RV) in one animal and through the tricuspid annulus in another, which presented important pericardial bleeding and cardiac tamponade. The hypothesis that an occlusion device could be useful to close the created atrial xiv orifice was tested successfully in thee pigs (two at RAA and one at RV) and without significant pericardial bleeding. Conclusions The right atrial appendage route might be potentially useful to access the normal pericardial space for mapping and ablating cardiac arrhythmias as well as to drain promptly an acute tamponade

Page generated in 0.0882 seconds