• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 42
  • Tagged with
  • 44
  • 44
  • 27
  • 24
  • 13
  • 13
  • 10
  • 8
  • 8
  • 7
  • 7
  • 7
  • 6
  • 6
  • 6
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
1

Avaliação do comportamento acústico de auditórios com ênfase nos critérios da inteligibilidade da fala

Oliveira, Gabriella Kurtz January 2015 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico, Programa de Pós-Graduação em Arquitetura e Urbanismo, Florianópolis, 2015. / Made available in DSpace on 2016-04-19T04:05:09Z (GMT). No. of bitstreams: 1 337897.pdf: 5711396 bytes, checksum: ece73f7d72e0cca61da2accecc338b6a (MD5) Previous issue date: 2015 / Uma comunicação falada adequada é de extrema importância para várias finalidades e em diferentes tipos de ambientes como, por exemplo, salas de aula, auditórios, aeroportos e ambientes de trabalho em geral, onde mensagens importantes ou de emergência devem ser transmitidas. No meio acadêmico, a inteligibilidade da palavra é o principal requisito exigido dentre as qualidades acústicas de um ambiente, em função tanto do desempenho intelectual dos ouvintes, quanto para a saúde destes e dos oradores. Essa boa qualidade do discurso depende das características acústicas do local e pode ser avaliada através do Índice de Transmissão da Fala (STI). No presente trabalho, oito auditórios selecionados entre os Centros de Ensino da Universidade Federal de Santa Catarina (UFSC) foram caracterizados através de medições acústicas da resposta impulsiva, conforme recomendações da norma ISO 3382:2009. Assim, foram obtidas respostas dos parâmetros acústicos como o tempo de reverberação (TR), o tempo de decaimento inicial (EDT), a definição da fala (D50), a clareza (C80) e o STI, as quais foram comparadas com os cálculos analíticos dos dois principais parâmetros ligados à inteligibilidade da fala: o TR e o STI. Para o cálculo do STI, as medições do tempo de reverberação e do ruído de fundo permitiram a quantificação do fator de redução de modulação, sendo possível realizar uma análise do STI por bandas de frequências de oitava. Por fim, foi realizada uma simulação do comportamento dos auditórios, frente ao TR e ao STI, quando ocupados. De uma forma geral, os resultados de TR e EDT demostraram ambientes muito reverberantes, com médias que variam entre 0,5 e 3,1 segundos, e 0,3 e 6,6 segundos, respectivamente, quando desocupados. A definição (D50) variou na faixa de 2,6% a 88,7%, e a clareza (C80), entre -13,5 e 13,3 dB com a maioria dos auditórios estando na sua faixa adequada de valores neste parâmetro. Quanto ao STI, de todos os ambientes avaliados, apenas um é considerado ?bom?, três são ?razoáveis? e quatro ?pobres?, classificados de acordo com a norma ISO 3382. Quando confrontados com os valores na situação de máxima ocupação, há uma melhora considerável dos parâmetros. A comparação do método analítico com o experimental, e as curvas de redução de modulação permitem julgar positivamente os métodos utilizados como confiáveis e possíveis ferramentas de projeto para uso dos profissionais da área, visto que os valores de desvios padrão não ultrapassam 0,02.<br> / Abstract : An adequate speech communication is extremely important for many purposes and in different types of environments, for example, classrooms, auditoriums, airports and general working environment where important or emergency messages should be transmitted. In academic field the speech intelligibility is the main requirement demanded from the acoustic qualities of an environment, in function of intellectual performance of listeners for their health and speakers. This good quality of speech depends of acoustic characteristics of the place and it can be evaluated through of Speech Transmission Index (STI). In the present work eight auditoriums were selected between Studies Center of Federal University of Santa Catarina (UFSC) were characterized by acoustic impulse response measurements, according to recommended by the standard ISO 3382:2009. Thus acoustic parameters responses were obtained such as reverberation time (RT), the early decay time (EDT), the definition of speech (D50), clarity (C80) and the STI, and were compared to analytical calculations two main parameters related to speech intelligibility: the RT and the STI. For the calculation of the speech transmission index (STI), the measurements about reverberation time and background noise allowed quantification of the modulation reduction factor it being possible to perform an analysis by the STI octave bands of frequencies. Finally it carried out a simulation of the behavior of auditoriums across the RT and STI when occupied. In general the results of RT and EDT demonstrated very reverberant environments with average ranging between 0.5 and 3.1 seconds, and 0.3 and 6.6 seconds respectively when unoccupied. The definition (D50) varied in the range of 2.6% to 88.7%, and the clarity (C80) between -13.5 and 13.3 dB with the most auditoriums in their adequate range of values of this parameter. About the STI, all environments evaluated only one is considered ?good?, three are ?reasonable? and four ?poor?, classified according to the standard ISO 3382. When faced with the values in the situation of maximum occupancy there are improvement considerable parameters. The comparison of the analytical method with the experimental, and the modulation reduction curves, allows positively judge the methods used as reliable and possible design tools for use by professional in the field of acoustic, evidenced by the standard deviations values that do not exceed 0.02.
2

Análise de desempenho térmico e acústico de fachadas ventiladas de porcelanato à luz da norma de desempenho : estudo de caso em Brasília-DF / Analysis of thermal and acoustic performance of porcelain ventilated facades in accordance with the performance standard : case study in Brasilia-DF

Santos Filho, Vamberto Machado dos 19 June 2015 (has links)
Dissertação (mestrado)—Universidade de Brasília, Faculdade de Tecnologia, Departamento de Engenharia Civil e Ambiental, 2015. / Submitted by Fernanda Percia França (fernandafranca@bce.unb.br) on 2015-12-04T16:54:24Z No. of bitstreams: 1 2015_VambertoMachadodosSantosFilho .pdf: 4240732 bytes, checksum: 41c80f946e3069bc64b8f9693b72a8b4 (MD5) / Approved for entry into archive by Raquel Viana(raquelviana@bce.unb.br) on 2016-05-19T19:22:03Z (GMT) No. of bitstreams: 1 2015_VambertoMachadodosSantosFilho .pdf: 4240732 bytes, checksum: 41c80f946e3069bc64b8f9693b72a8b4 (MD5) / Made available in DSpace on 2016-05-19T19:22:03Z (GMT). No. of bitstreams: 1 2015_VambertoMachadodosSantosFilho .pdf: 4240732 bytes, checksum: 41c80f946e3069bc64b8f9693b72a8b4 (MD5) / A entrada de novos sistemas construtivos no mercado brasileiro tem sido acompanhada de diversos questionamentos sobre o seu desempenho. Entre estes novos sistemas estão as Fachadas Ventiladas, que surgem com o apelo de um sistema com o potencial de melhorar os aspectos de habitabilidade da edificação. Esse sistema é caracterizado por uma camada de ventilação entre os painéis externos modulares e o substrato, prevendo um espaço vazio que permite, por efeito chaminé, uma ventilação continua. Neste trabalho foi realizado um estudo de desempenho de fachadas ventiladas com porcelanato (FVPo), comparativamente às fachadas de porcelanato aderido (FPoA). Para isto, foi utilizado um projeto de uma edificação habitacional modelo (EHM) para reproduzir as edificações típicas do Plano Piloto de Brasília-DF. Suas características, materiais e elementos de contorno permaneceram constantes, sendo a variável apenas o tipo da fachada. Para o auxílio dos cálculos do desempenho foram utilizados dois diferentes softwares, o Design Builder, para o desempenho térmico, e o Insul, para o desempenho acústico. Os critérios de análise foram estabelecidos pela norma de desempenho. Em cada critério da norma, os dois sistemas foram comparados e analisados com base nos resultados obtidos da simulação. As fachadas ventiladas de porcelanatos obtiveram melhores resultados de desempenho térmico, em todas as metodologias utilizadas, quando comparados à fachada de porcelanato aderido. Essa melhoria de desempenho pode ser explicada pelo fato de sua camada de ar ventilada renovar o ar aquecido diminuindo a transmissão de calor para o interior da edificação no período de verão, e evitar a transmissão de calor para o exterior da edificação nos períodos de inverno. Nas simulações de acústica os dois sistemas apresentaram o mesmo índice de isolamento sonoro, com um nível mínimo de desempenho, segundo critério da norma. Foi possível verificar a importância da esquadria no isolamento do sistema de fachada, pois ao aumentar a área da esquadria, o índice de isolamento diminui. / The insertion of new construction systems in the Brazilian market has been accompanied by many questions about its performance. Among these new systems are the Ventilated Facades, which come with the appeal of a system with the potential to improve aspects of habitability of the building. In this article, were compared two types of facades, a conventional, adhered facade of porcelain (FPoA), and an innovative one, the ventilated facade of porcelain (FVPo). To achieve the objectives, it was constructed a residential building model (EHM) which has the objective to reproduce the typical buildings of the Plano Piloto in Brasilia-DF. It’s features, materials and boundary element remained constant, changing only the type of the facade. The thermal and acoustic performance of these two systems was verified with the performance standard, using software to aid in the calculations, the Design Builder for thermal and the Insul for acoustics. In each criterion of the standard, the two systems were compared and analyzed based on the results of the simulation. The ventilated facades of porcelain performed better thermal performance in all methodologies used, compared to the facade of joined porcelain. This performance improvement can be explained by the fact that its air layer ventilated renew the heated air reducing heat transfer into the building during the summer and prevents heat transfer to the outside of the building in the winter periods. In acoustic simulations the two systems had the same sound insulation index, with a minimum performance standard. It was possible to verify the importance of squarely in insulation façade system, because by increasing the area of the miter, the isolation index decreases.
3

Estudo da qualidade acústica de salas multiuso para o ensino e prática musical por meio de medições experimentais e simulação computacional

Lima, Pollyanna Rodrigues January 2017 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro Tecnológico, Programa de Pós-Graduação em Arquitetura e Urbanismo, Florianópolis, 2017. / Made available in DSpace on 2017-10-31T03:13:34Z (GMT). No. of bitstreams: 1 348921.pdf: 3480852 bytes, checksum: d1542d92391bab4f5f41e40b5e9a6262 (MD5) Previous issue date: 2017 / Para que o músico desfrute de uma experiência satisfatória no ambiente de sua prática musical, além dos requisitos mínimos de projeto (como conforto térmico, lumínico, ergonômico, acessibilidade), um projeto acústico específico é essencial. Em um contexto onde cada vez mais um mesmo ambiente é utilizado para usos que requerem projetos acústicos distintos, as três salas de aula da Coordenação Artística do IFSC Campus Florianópolis vêm sendo utilizadas para diversas atividades artísticas dentre as quais se destaca a prática musical. Partindo do pressuposto de que as três salas não se encontravam adequadas às práticas musicais, esse trabalho se dedicou a caracterizar o ambiente acústico de cada uma das salas através de ensaios experimentais e simulação computacional a fim de simular alternativas que possam adequá-las ao uso. Por meio de um Estudo Piloto realizado com dados pré-existentes, foi possível testar os instrumentos e procedimentos da simulação computacional, realizada com o software Odeon. Os principais parâmetros acústicos (TR, EDT, C80, D50, STI) de cada uma das salas foram obtidos experimentalmente de acordo com os procedimentos indicados pela norma ISO 3382: 2009, posteriormente tratados, analisados e comparados com os valores indicados pela literatura para a prática musical. Os valores obtidos não se encontravam dentro desses limites. Para testar diferentes alternativas fazendo uso da simulação computacional, foi necessário antes desenvolver um modelo computacional fiel ao modelo real, o que foi possível através de ajustes nas especificações acústicas dos materiais e comparando os dados obtidos nas simulações com aqueles obtidos experimentalmente, cuja diferença entre eles deveria estar dentro do limiar diferencial (JND), de acordo com a norma ISO 3382: 2009. Após resultar em modelos computacionais fiéis aos modelos reais das salas, diferentes alternativas de soluções foram testadas a fim de obter modelos que adequassem as salas à prática musical. Os modelos mais adequados foram apresentados, indicando as especificações necessárias para a adaptação das salas. Os métodos se mostraram válidos, e a possibilidade de adequação de salas de aula multiuso para a prática musical se mostrou possível através da realização de uma análise acústica do ambiente, possibilitando a indicação apropriada de inserção e/ou remoção de materiais e dispositivos acústicos que otimizaram a resposta acústica da sala. / Abstract : For the musician enjoy a satisfactory experience in your musical practice environment, beyond the minimum requirements of project (such as thermal comfort, light, ergonomic, accessibility), a specific acoustic design is essential. In a context where increasingly the same environment is utilized for uses that require distinct acoustic projects, the three classrooms of the Artistic Coordination of the IFSC Florianópolis Campus have been used for various artistic activities among which stands out the musical practice. Assuming that both the three rooms were not suited to musical practice, this work is devoted to characterize the acoustic environment of each one of the rooms through experimental tests and computer simulation in order to simulate alternatives that may suit them to use. Through a pilot study conducted with pre-existing data, it was possible to test the instruments and procedures of the computer simulation, performed with the Odeon software. The main acoustic parameters (RT, EDT, C80, D50, STI) of each of the rooms were obtained experimentally in accordance with the procedures set out by the ISO 3382:2009, further processed, analyzed and compared with the values indicated by the literature for the musical practice. The values obtained were not within the limits indicated. To test different alternatives making use of computer simulation, was necessary before developing a computational model faithful to the real model, which was made possible through adjustments to the acoustic specifications of materials and comparing the data obtained in simulations with those obtained experimentally, whose difference between them should be within the differential threshold (JND), according to ISO 3382 : 2009. After working in computational models faithful to actual models of different alternative solutions were tested in order to obtain models that adapt the music practice rooms. The most appropriate models were presented, indicating the required specifications for the adaptation of the rooms. The methods have proven to be valid, and the possibility of adaptation of multipurpose classrooms for music practice proved possible by performing an acoustic analysis of the environment, enabling the appropriate indication of insertion and/or removal of materials and acoustic devices that have optimized the acoustic response of the room.
4

Método para avaliação do desempenho térmico e acústico de edificações aplicado em painéis de fechamento industrializados.

Ribas, Rovadavia Aline de Jesus January 2013 (has links)
Programa de Pós Graduação em Engenharia Civil. Departamento de Engenharia Civil, Escola de Minas, Universidade Federal de Ouro Preto. / Submitted by Maurílio Figueiredo (maurilioafigueiredo@yahoo.com.br) on 2014-06-30T19:07:54Z No. of bitstreams: 2 license_rdf: 22190 bytes, checksum: 19e8a2b57ef43c09f4d7071d2153c97d (MD5) TESE_MétodoAvaliaçãoDesempenho.pdf: 7266523 bytes, checksum: 4b40d0f10449db7609ee6947fe1c9c4a (MD5) / Approved for entry into archive by Gracilene Carvalho (gracilene@sisbin.ufop.br) on 2014-07-17T18:45:20Z (GMT) No. of bitstreams: 2 license_rdf: 22190 bytes, checksum: 19e8a2b57ef43c09f4d7071d2153c97d (MD5) TESE_MétodoAvaliaçãoDesempenho.pdf: 7266523 bytes, checksum: 4b40d0f10449db7609ee6947fe1c9c4a (MD5) / Submitted by Maurílio Figueiredo (maurilioafigueiredo@yahoo.com.br) on 2015-01-21T18:56:58Z No. of bitstreams: 2 license_rdf: 22190 bytes, checksum: 19e8a2b57ef43c09f4d7071d2153c97d (MD5) TESE_MétodoAvaliaçãoDesempenho.pdf: 7266523 bytes, checksum: 4b40d0f10449db7609ee6947fe1c9c4a (MD5) / Approved for entry into archive by Gracilene Carvalho (gracilene@sisbin.ufop.br) on 2015-01-21T18:58:44Z (GMT) No. of bitstreams: 2 license_rdf: 22190 bytes, checksum: 19e8a2b57ef43c09f4d7071d2153c97d (MD5) TESE_MétodoAvaliaçãoDesempenho.pdf: 7266523 bytes, checksum: 4b40d0f10449db7609ee6947fe1c9c4a (MD5) / Submitted by Maurílio Figueiredo (maurilioafigueiredo@yahoo.com.br) on 2015-01-23T17:08:28Z No. of bitstreams: 2 license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) TESE_MétodoAvaliaçãoDesempenho.pdf: 7266523 bytes, checksum: 4b40d0f10449db7609ee6947fe1c9c4a (MD5) / Approved for entry into archive by Gracilene Carvalho (gracilene@sisbin.ufop.br) on 2015-01-26T11:33:50Z (GMT) No. of bitstreams: 2 license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) TESE_MétodoAvaliaçãoDesempenho.pdf: 7266523 bytes, checksum: 4b40d0f10449db7609ee6947fe1c9c4a (MD5) / Made available in DSpace on 2015-01-26T11:33:50Z (GMT). No. of bitstreams: 2 license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) TESE_MétodoAvaliaçãoDesempenho.pdf: 7266523 bytes, checksum: 4b40d0f10449db7609ee6947fe1c9c4a (MD5) Previous issue date: 2013 / A construção industrializada estruturada em aço pode proporcionar projetos que apresentam desempenho global adequado, desde que o sistema de fechamento apresente desempenho térmico e acústico apropriados ao clima local e ao entorno da edificação. No entanto, a rapidez de montagem desse sistema construtivo exige a aplicação de sistemas de fechamento que possuam a mesma filosofia de pré-fabricação, e uma seleção inadequada pode resultar em necessidade de interferências futuras e resistência à utilização da construção estruturada em aço. É imperativo que os sistemas de fechamento proporcionem desempenho térmico e acústico equilibrado, pois a qualidade do som no ambiente pode afetar tanto o conforto acústico quanto o conforto térmico. No mercado nacional, há vários sistemas de fechamento industrializados que precisam de mais conhecimento quanto às suas propriedades térmicas e acústicas. O objetivo desse trabalho é propor um método para avaliação do desempenho térmico e acústico de edificações, aplicado a sistemas de fechamento industrializados, como os painéis de placa cimentícia, gesso acartonado, pré-moldado de concreto, concreto celular autoclavado e poliestireno expandido. O estudo é realizado em painéis simples e painéis compostos por multicamadas. O método para a análise térmica é baseado na determinação da temperatura e umidade relativa no interior dos ambientes de edificações modelo, aplicando-se o programa computacional de simulação ESP-r (Energy Simulation Program – research). Para a análise acústica é feito o cálculo do tempo de reverberação aplicando-se uma formulação empírica e o módulo acústico do ESP-r, que utilizam os valores de temperatura e umidade obtidos na simulação numérica, além da estimativa da perda na transmissão sonora dos sistemas de fechamento, aplicando-se um método gráfico. Os resultados possibilitam uma avaliação preliminar de parâmetros relevantes na definição de sistemas de fechamento apropriados para uma determinada situação, em termos de desempenho térmico e acústico. Observa-se que, de modo geral, os fechamentos em multicamadas, intermediados por lã de vidro e ar, proporcionam um desempenho térmico e acústico superior ao fechamento simples convencional, com uma melhora no desempenho, respectivamente, na ordem de 12 % e de 18 %. __________________________________________________________________________________________ / ABSTRACT: Industrialized steel-structured construction techniques allow designs that could lead to a suitable building global performance if the closing system has thermal and acoustical performance features appropriate to the local climate and to the edification surroundings. However, the assembling quickness these techniques allow demands using closing systems that present the same prefabrication features, and an inappropriate choice of the systems may result in the need of future interventions, and in resistance against the adoption of steelstructured construction. Thus, it is mandatory that the closing systems provide a balanced thermal and acoustical performance, because the quality of sound in the environment can affect the thermal and acoustical comfort. In Brazilian national market there are many industrialized closing systems that need a better understanding about their thermal and acoustic properties. The purpose of this article is to propose a method for the evaluation of thermal and acoustic performance of edifications, applied to their industrialized closing systems, such as cement sheet, drywall, precast concrete panels, autoclaved cellular concrete, and expanded polystyrene. The study was carried out in single panels and in multilayered panels. The method used for the thermal analysis is based on determining the temperature and relative humidity within the model buildings environments, by applying the computational simulation program ESP-r (Energy Simulation Program – research). The acoustic analysis is carried out by calculating the reverberation time, by means of an empirical formulation and the acoustical module of ESP-r, which use the temperature and humidity values obtained from the numerical simulation, besides a graphical method for the estimation of the sound transmission loss of the closing system. The results provide a preliminary assessment of parameters relevant in the definition of closing systems appropriate for the situation under study, in terms of thermal and acoustic performance. In general, it was observed that the multilayered closing systems intermediated by glass wool and air provide a thermal and acoustic performance superior to the conventional single-layer closing system, with an improvement in performance, respectively, on the order of 12 % and 18 %.
5

Avaliação das condições de conforto térmico e acústico de salas de aula em escola de tempo integral : estudo de caso da Escola Padre Josimo em Palmas (TO)

Dias, Adriana 05 October 2009 (has links)
Dissertação (mestrado)—Universidade de Brasília, Faculdade de Arquitetura e Urbanismo, 2009. / Submitted by Marcos Felipe Gonçalves Maia (felipehowards@gmail.com) on 2010-06-04T13:01:20Z No. of bitstreams: 1 dissertacao Adriana Dias final_reduzido.pdf: 5881878 bytes, checksum: 6ab008e99c0c8a2eae764aceac7bfa36 (MD5) / Approved for entry into archive by Daniel Ribeiro(daniel@bce.unb.br) on 2010-06-04T19:07:40Z (GMT) No. of bitstreams: 1 dissertacao Adriana Dias final_reduzido.pdf: 5881878 bytes, checksum: 6ab008e99c0c8a2eae764aceac7bfa36 (MD5) / Made available in DSpace on 2010-06-04T19:07:40Z (GMT). No. of bitstreams: 1 dissertacao Adriana Dias final_reduzido.pdf: 5881878 bytes, checksum: 6ab008e99c0c8a2eae764aceac7bfa36 (MD5) Previous issue date: 2009-10-05 / Este trabalho expõe a necessidade de obtenção do conforto térmico e acústico em Escolas de Tempo Integral (ETIs) em Palmas - TO. Escolheram-se dois parâmetros: térmico e acústico. O térmico em decorrência das elevadas temperaturas constantes durante o ano e no contexto acústico, em função dos conflitos gerados pelas inúmeras atividades esportivas e artísticas oferecidas nas ETIs, de forma simultânea às do currículo formal. O conforto térmico e acústico podem interferir positivamente no processo de crescimento intelectual dos alunos, pois estão diretamente relacionados ao desempenho do ensino-aprendizagem dos usuários das referidas escolas. Para tanto, coletaram-se os dados de temperatura, umidade e dos níveis de ruídos no interior das salas de aula em horário crítico. Aplicou-se questionário aos professores e demais funcionários da escola, com perguntas abertas e fechadas, relacionadas ao conforto térmico e acústico da edificação. Posteriormente, analisou-se o projeto arquitetônico, considerando-se a implantação do edifício, a forma e a disposição, os materiais aplicados e as aberturas, juntamente com os fatores climáticos de Palmas. De posse dos dados, cruzaram-se as informações coletadas com os parâmetros estabelecidos nas Normas Brasileiras (NBRs) vigentes. Com base nestes elementos, assim como nos conceitos expostos dos renomados autores referentes ao tema, elaboraram-se sugestões para projeto arquitetônico de ETIs em Palmas. _________________________________________________________________________________ ABSTRACT / This work presents the necessity to obtain the thermal and acoustic comfort in the full time schools in Palmas – TO. Two standards were.chosen: thermal and acoustic. This was due to the current high temperatures in Palmas and acoustic context, which are conflicts generated by the various artistic and sportive activities offered simultaneously with the formal curriculum in the full time school. The thermal and acoustic comfort. can interfere positively in the intelectual developing of the students because it is related to the teaching and learning performance of the users of the mentioned schools. So that it was possible, temperature and humidity data were registered, and also the sound levels in the classrooms in their peaks. A questionnaire with opened and closed questions related to thermal and acoustic comfort was applied to the teachers and staff. After that, the architectural project was analysed taking into consideration the building implantation, the form and display, materials and also the openings along with the climatic factors in Palmas. Having the available data, these pieces of information were co-related with stablished standarts in the Brazilian Rules (NBRs). Furthermore, reliable authors concepts related to this subject were also used in order to help the suggested architectural project of full time schools in Palmas.
6

Análise acústica de auditórios musicais depois de construídos

Marco, Conrado Jorge Silva de 12 1900 (has links)
Tese (doutorado)-Universidade de Brasília, Faculdade de Arquitetura e Urbanismo, 2009. / Submitted by Suelen Silva dos Santos (suelenunb@yahoo.com.br) on 2010-11-25T17:04:30Z No. of bitstreams: 1 2009_ConradoJorgeSilvadeMarco.pdf: 3957866 bytes, checksum: 06898082e758b6348317a505d01df86f (MD5) / Approved for entry into archive by Daniel Ribeiro(daniel@bce.unb.br) on 2010-11-30T22:31:13Z (GMT) No. of bitstreams: 1 2009_ConradoJorgeSilvadeMarco.pdf: 3957866 bytes, checksum: 06898082e758b6348317a505d01df86f (MD5) / Made available in DSpace on 2010-11-30T22:31:13Z (GMT). No. of bitstreams: 1 2009_ConradoJorgeSilvadeMarco.pdf: 3957866 bytes, checksum: 06898082e758b6348317a505d01df86f (MD5) / A tese propõe uma metodologia de análise da acústica de auditórios já construídos, com o fim de prover ferramentas para a correção do projeto acústico e da construção, tendo a finalidade de possibilitar melhores resultados na resposta acústica da sala. São analisados os princípios básicos do projeto acústico, a história do auditório e os critérios que fundamentam a qualidade do projeto acústico. São citados e analisados exemplos de auditórios que foram corrigidos depois de sua construção. Entre eles a Salle Pleyel, Paris, o Avery Fisher Hall, Nova York, o Teatro Colón, Buenos Aires e o Teatro Solís, Montevidéu. Uma análise mais aprofundada, com cálculos e medições de tempos de reverberação foi realizada para três auditórios de Brasília de características totalmente diferentes: a Sala Villa-Lobos do Teatro Nacional, o Anfiteatro N. 9 da Universidade de Brasília e a Sala Jacob Germano Galler da Casa Thomas Jefferson - Asa Norte. Nas Recomendações são fornecidos esquemas da correção dos auditórios brasilienses e listados os pontos para estabelecer uma sistemática da análise. _________________________________________________________________________________ ABSTRACT / The dissertation proposes a methodology for analyzing the acoustics of build auditoriums, giving tools to correct the acoustical design and construction, in order to provide better results in the acoustical room response. It analyzes the basic principles of acoustic design, the history of the auditorium and the criteria underlying the quality of acoustic design. Examples of halls that were corrected after its construction are cited and discussed. Amongst them are the Salle Pleyel, Paris, Avery Fisher Hall, New York, the Teatro Colón, Buenos Aires and the Teatro Solís from Montevideo. Further analysis, with calculations and measurements of reverberation time, was held to three auditoriums in Brasilia with completely different characteristics: the Sala Villa-Lobos's National Theater, the AnfiteatroN. 9, at the Universidade de Brasília and Jacob Germano Galler Hall at the Casa Thomas Jefferson - Asa Norte. In the Recommendations Chapter, schemes for the correction of the auditoriums made in Brasília are provided and points to establish a systematic approach are listed.
7

Desempenho acústico de templos e igrejas: subsídios à normalização / Acoustic performance evaluation of 3 churches, based on brazilian normalization

Moscati, Sandra Rachel 09 April 2013 (has links)
Este trabalho aborda a problemática da acústica de igrejas construídas a partir da segunda metade do século XX por meio da revisão bibliográfica e do estudo de caso de três igrejas na cidade de São Paulo. O objetivo da pesquisa é estudar o desempenho dos espaços sonoros internos e externos de três templos, escolhidos como amostras, com base na normalização brasileira vigente. Avaliaram-se por meio de medições acústicas o tempo de reverberação nas naves, o nível de ruído ambiente em frente às igrejas, o nível de ruído ambiente interno nas naves das igrejas, bem como o nível sonoro nas naves e em frente às igrejas durante os cultos religiosos. Com isso procurou-se realizar o levantamento dos problemas enfrentados pelas igrejas em relação à qualidade acústica nas naves e as possíveis interferências que causam à comunidade vizinha, quanto aos níveis sonoros emitidos. O equipamento de medição utilizado foi um analisador profissional de áudio. A arquitetura das igrejas e sua localização e implantação na cidade são determinantes para a qualidade acústica das naves e os níveis sonoros emitidos no entorno. A pesquisa revelou que o nível de ruído ambiente em frente às igrejas interfere na relação sinal/ruído nas naves e que a interferência do nível sonoro emitido no ambiente externo pelas igrejas durante o seu funcionamento depende da localização, condições de uso e sobretudo de suas condições arquitetônicas. Estas condições, quando mal resolvidas, decorrem de projetos em que os requisitos acústicos não foram observados ou deixados de lado durante a execução da obra. / This paper discusses the acoustic of churches built from the second half on of the twentieth century based on literature survey and the specific case study of three churches in the city of São Paulo. The objective of this research is to study the performance of internal and external sound in three temples, chosen as samples, based on the Brazilian standards in force. Measurements of the acoustic reverberation time in the aisle, the internal and external noise level of the environment, as well as in front of the churches during religious services were performed. Therefore, the survey of the problems faced by the churches regarding the acoustic quality in the aisles and possible interferences that it may cause to the surrounding community were evaluated. The measuring equipment used was a professional audio analyzer. The architecture of the churches, their implementation and location in the city are crucial to the acoustic quality of the aisles and sound levels emitted to the environment. The research revealed that the ambient noise level in front of the churches interferes in the signal / noise in aisles and the interference of sound emitted by the churches in the external environment during operation depends on the location, conditions of use and mainly its architectural conditions. These conditions, if poorly solved, result from projects in which the acoustic requirements were not observed or left out during the execution of the building
8

Desempenho acústico de templos e igrejas: subsídios à normalização / Acoustic performance evaluation of 3 churches, based on brazilian normalization

Sandra Rachel Moscati 09 April 2013 (has links)
Este trabalho aborda a problemática da acústica de igrejas construídas a partir da segunda metade do século XX por meio da revisão bibliográfica e do estudo de caso de três igrejas na cidade de São Paulo. O objetivo da pesquisa é estudar o desempenho dos espaços sonoros internos e externos de três templos, escolhidos como amostras, com base na normalização brasileira vigente. Avaliaram-se por meio de medições acústicas o tempo de reverberação nas naves, o nível de ruído ambiente em frente às igrejas, o nível de ruído ambiente interno nas naves das igrejas, bem como o nível sonoro nas naves e em frente às igrejas durante os cultos religiosos. Com isso procurou-se realizar o levantamento dos problemas enfrentados pelas igrejas em relação à qualidade acústica nas naves e as possíveis interferências que causam à comunidade vizinha, quanto aos níveis sonoros emitidos. O equipamento de medição utilizado foi um analisador profissional de áudio. A arquitetura das igrejas e sua localização e implantação na cidade são determinantes para a qualidade acústica das naves e os níveis sonoros emitidos no entorno. A pesquisa revelou que o nível de ruído ambiente em frente às igrejas interfere na relação sinal/ruído nas naves e que a interferência do nível sonoro emitido no ambiente externo pelas igrejas durante o seu funcionamento depende da localização, condições de uso e sobretudo de suas condições arquitetônicas. Estas condições, quando mal resolvidas, decorrem de projetos em que os requisitos acústicos não foram observados ou deixados de lado durante a execução da obra. / This paper discusses the acoustic of churches built from the second half on of the twentieth century based on literature survey and the specific case study of three churches in the city of São Paulo. The objective of this research is to study the performance of internal and external sound in three temples, chosen as samples, based on the Brazilian standards in force. Measurements of the acoustic reverberation time in the aisle, the internal and external noise level of the environment, as well as in front of the churches during religious services were performed. Therefore, the survey of the problems faced by the churches regarding the acoustic quality in the aisles and possible interferences that it may cause to the surrounding community were evaluated. The measuring equipment used was a professional audio analyzer. The architecture of the churches, their implementation and location in the city are crucial to the acoustic quality of the aisles and sound levels emitted to the environment. The research revealed that the ambient noise level in front of the churches interferes in the signal / noise in aisles and the interference of sound emitted by the churches in the external environment during operation depends on the location, conditions of use and mainly its architectural conditions. These conditions, if poorly solved, result from projects in which the acoustic requirements were not observed or left out during the execution of the building
9

Auralização : tecnicas de modelagem e simulação binaural de ambientes acusticos virtuais

Fernandes Junior, Antonio Carlos Lopes, 1976- 28 July 2005 (has links)
Orientador: Furio Damiani / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Eletrica e de Computação / Made available in DSpace on 2018-08-05T12:59:57Z (GMT). No. of bitstreams: 1 FernandesJunior_AntonioCarlosLopes_M.pdf: 1435718 bytes, checksum: 49c2a21e1e1cacc931b6020b594d3e9e (MD5) Previous issue date: 2005 / Resumo: Auralização é um termo utilizado para significar as técnicas que tornam um campo sonoro audível por modelagem física ou matemática da fonte sonora, do ambiente e do ouvinte. O presente trabalho tem como objetivo principal a análise de processos de modelagem inteiramente computacionais para a constituição de ambientes acústicos virtuais que podem ser implementados e simulados, interativamente, em um computador pessoal e experienciados, perceptualmente, via fones de ouvido. Os conceitos de resposta impulsiva e função de transferência são utilizados para modelar os espaços acústicos e as transformações impelidas pelo torso, cabeça e orelhas ao som que atinge um ouvinte. Esta dissertação dá ênfase às modelagens do ambiente e do ouvinte e ressalta os aspectos mais importantes das abordagens utilizadas para as fontes sonoras / Abstract: Auralization is a term used to signify the techniques that render audible a sound field through the mathematical or physical modeling of the sound source, the acoustic space and the listener. The present work aims to analyse fully computed process of modeling to the constitution of virtual acoustics environments that can be implemented and interactively simulated in a personal computer and perceptually experienced through headphones. The concepts of impulse response and transfer function are used to model acoustic spaces and the transformations compelled by torso, head and ears to the sound that hits a listener. This dissertation give emphasis to the environment and listener modeling and give some light on the most important aspects of the approaches used to the sound sources / Mestrado / Mestre em Engenharia Elétrica
10

Sistema ultra-sonico para medida volumetrica

Silva, Isaias Ferreira da 28 July 2018 (has links)
Orientador: Carlos Alberto dos Reis Filho / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Engenharia Eletrica e de Computação / Made available in DSpace on 2018-07-28T14:25:31Z (GMT). No. of bitstreams: 1 Silva_IsaiasFerreirada_M.pdf: 4466930 bytes, checksum: ad46dce85a289d4ec4bb0692137830e9 (MD5) Previous issue date: 1999 / Resumo: Um método inovador para a medida do volume de um líquido dentro de um recipiente fechado é proposto. A motivação deste trabalho é a aplicação do método para a medida do volume de combustível dentro de um tanque de automóvel. Este método se baseia no fenômeno de reverberação sonora que relaciona o tempo de decaimento da intensidade do som dentro de um ambiente com o seu volume. Este tempo, conhecido como tempo de reverberação, está associado ao volume vazio dentro do recipiente, ao material com o qual é feito e ao tipo de líquido que este recipiente contém. Sendo conhecido o volume total do recipiente, determina-se o volume de líquido presente. Para determinar a relação existente entre o tempo de reverberação e o volume de líquido é necessário conhecer as características acústicas do sistema; para isto foram realizados experimentos em um recipiente metálico de dimensões semelhantes as de um tanque automotivo, utilizando-se água como líquido cujo volume deve ser medido. Como fonte sonora utiliza-se um transdutor de ultra-som ao qual se aplicam pulsos de excitação periódica. O resultado destes experimentos têm confirmado a validade do método proposto / Abstract: An innovative method to measure the liquid volume inside an enc1osure container is proposed. The motivation for this research work has been the development of a system to measure the fuel volume in an automotive fuel tank. This method is based on the reverberation phenomenon, which relates the sound power time decay in a vessel with its volume. By measuring this time, which is known as reverberation time, the empty volume inside the enc1osurecan be determined. Once the total volume is known the liquid volume is found. The reverberation time is dependent on the empty volume inside the enclosure, the material properties of the vessel and the liquid inside the enclosure. The acoustical characteristics of the system are determined by several experiments with a metallic enclosure, whose dimensions are approximately the same as those an automotive fuel tank. The sound source is an ultrasonic transducer excited by periodic bursts. Experimental results have confirmed the validity of the proposed method / Mestrado / Eletronica e Comunicações / Mestre em Engenharia Elétrica

Page generated in 0.0674 seconds