• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 128
  • 13
  • 13
  • 13
  • 12
  • 12
  • 11
  • 5
  • 4
  • 2
  • 1
  • 1
  • 1
  • Tagged with
  • 132
  • 132
  • 59
  • 52
  • 39
  • 34
  • 31
  • 28
  • 28
  • 23
  • 17
  • 15
  • 15
  • 15
  • 15
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
11

Resistencia ao cisalhamento de braquetes fixados com resinas polimerizadas por diferentes tipos de ativação

Guedes-Pinto, Eduardo 27 November 1997 (has links)
Orientador: Simonides Consani / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-23T01:37:33Z (GMT). No. of bitstreams: 1 Guedes-Pinto_Eduardo_M.pdf: 2855830 bytes, checksum: ffca1786148a3514f02f16d72b6577e2 (MD5) Previous issue date: 1997 / Resumo: A proposta deste estudo foi avaliar a resistência ao cisalhamento de três materiais de colagem, polimerizados por diferentes sistemas de ativação. Foram utilizados 60 pré-molares humanos, extraídos com finalidade de tratamento ortodôntico. As faces vestibulares foram condicionadas com ácido fosfórico a 37% durante 30 segundos e os bráquetes fixados ao esmalte dentário com as . resinas Concise Ortodôntico (3M), Z-100 (3M) e cimento resinoso Dual (3M). Após a fixação dos bráquetes metálicos, os corpos-de-prova foram submetidos ao teste de cisalhamento 10 minutos e 24 horas após as colagens. Os resultados submetidos à análise estatística mostraram que houve diferença estatisticamente significante entre os três tipos de resina para os dois períodos de tempo de armazenamento. O sistema de colagem mais resistente foi promovido pelo Concise Ortodôntico, seguido pela resina fotoativada Z-100, e o menos resistente foi o cimento resinoso Dual. O tempo de armazenamento foi estatisticamente significante, pois representou aumento na resistência ao cisalhamento nos três tipos de materiais, provavelmente, devido à contínua conversão dos radicais livres / Abstract: The purpose of this study was to evaluate the shear bond strengths of three bonding materiaIs, activated by different systems. Sixty human premolars, extracted for orthodontic reasons, were used. Vestibular faces were etched for 30 seconds with 37% phosphoric acid gel and brackets were bonded to enamel surface using Concise chemically cured adhesive (3M), Z-100 light-cured adhesive (3M) and Dual cemerit resin (3M). After the bonding of metal brackets, specimens were tested and the shear stress at bond failure was recorded at 10 minutes and 24 hours. Results submitted to statistical analysis demonstrated a statistically significant difference in shear bond strengths among the three resins for both periods of storage. The most resistant bonding system was the Concise group, followed by the light-cured Z-100 and the less resistant Dual cement resin. The storage was statistically significant by increasing the shear bond strengths of the three materiaIs, probably because of the continue conversion / Mestrado / Ortodontia / Mestre em Ciências
12

Influencia do substrato dentinario e do material restaurador na infiltração marginal de restaurações cervicais

Saito, Solange Katia 08 January 2001 (has links)
Orientador : Jose Roberto Lovadino / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-28T23:46:19Z (GMT). No. of bitstreams: 1 Saito_SolangeKatia_D.pdf: 2022044 bytes, checksum: 1448f462721703745289700cf45f625b (MD5) Previous issue date: 2001 / Resumo: O objetivo deste trabalho foi avaliar, quantitativamente, a infiltração marginal de diferentes sistemas restauradores, quando colocados em substrato dentinário normal ou hipermineralizado artificialmente. Cento e oito cavidades foram confeccionadas em raízes de dentes bovinos e divididas em dois grupos experimentais (normal ou hipermineralizado), sendo subdivididas em quatro grupos, conforme o sistema restaurador utilizado: Vidrion R caps, Vitremer, Single Bond/Filtek Z250 e Clearfil SE Bond/Filtek Z250. A dentina foi hipermineralizada nas soluções: 1,5M de cálcio (CaCl2H2O, pH 5,7) por 1 hora e 1,5M de fosfato (K2HPO4, pH 9,5) por mais 1 hora, sendo, estocados em saliva artificial {1,5mM de cálcio (CaCl2H2O)+ 0,9mM de fosfato (K2HPO4)+ 0,15M de KCI; pH 7,0} por 24 horas, após a realização dos preparos cavitários. Os sistemas restauradores foram colocados em dentina hipermineralizada (Grupos I, ID, V e VII) e dentina normal (Grupos II, IV, VI e VllI). Os dentes restaurados foram submetidos a 1000 ciclos térmicos, entre temperaturas de 5 e 55±2°C. Em seguida, foram imersos em solução de azul de metileno a 2% por 24 horas. As amostras foram trituradas e o pó diluído em 4 ml de álcool absoluto. A infiltração marginal foi determinada e expressa em concentração de corante (ml). Os dados analisados pelos testes de Kruskal-Wallis e Ryan mostraram que não houve diferença estatística entre substrato; no entanto, houve diferença significante entre os materiais (p<0,01). Os resultados obtidos foram (mg/mI): GI-55,9a; GII-64,3a; GIII-12,lb; GIV-2I,2b; GV-32,9bc; GVI 30,lbc; GVll-41,9cd; GVIII-37,7cd. A microinfiltração relacionada com Vidrion R caps foi maior quando comparada com a dos outros materiais. As cavidades restauradas com Vitremer apresentaram valores de infiltração marginal semelhante ao sistema Single Bond/Filtek Z250 e este não diferiu do sistema Clearfil SE Bond/Filtek Z250 / Abstract: The aim of this study was to evaluate, quantitatively, the marginal leakage around different esthetic materials placed on normal and artificially hypermineralized cervical dentin cavities. One hundred eight cavities were prepared in bovine teeth roots and divided in two experimental groups (normal or hypermineralized), then subdivided in four subgroups according to the restorative system: Vidrion R caps, Vitremer, Single Bond/Filtek Z250 and Clearfil SE Bond/Filtek Z250. Dentin was hypermineralizing into the solutions contained: 1,5M calcium (CaCl2H20, pH 5,7) for 1 hour and 1,5M phosphate (K2HPO4, pH 9,5) for more 1 hour and then, stored in synthetic saliva {1,5mM calcium (CaCl2 H2O)+ 0,9mM phosphate (K2HPO4)+ 0,15M KCI; pH 7,0} for 24 hour, after cavities preparation. The restorative materials were placed in hipermineralized dentin (Groups 1, m, V and Vll) and normal dentin (Groups lI, IV, VI and VID). The restored teeth were submitted to 1000 thermal cycles between 5±2 °C and 55±:2 °C, then imersed in to 2% methylene blue solution for 24 hours. The samples were triturated and the powder were placed into absolute alcohol to dye extraction. The marginal leakage was determined and expressed by dye concentration (mm/ml). Data were analysed by the Kruskal-Wallis and Ryan test. The results were (mm/ml): GI- 55,9a; G-II 64,3a; G-III 12,lb; G-IV 21,2b; G-V 32,9bc; G-VI 30,lbc; G-VII 41,900; G-VIII 37,7cd. There was no statistically significant difference between the evaluated substrates; however, there was significant difference among materials (p<0,01). Microleakage related to Vidrion R caps material was greater than that any other material. Vitremer material presented the same marginalleakage values as Single BondIFiltek Z250. The latter didn't differ from Clearfil SE Bond system / Doutorado / Dentística / Doutor em Clínica Odontológica
13

Avaliação do laser Er:YAG como condicionador de esmalte e dentina para procedimento de união a materiais resinosos

Guimarães, Priscilla Santos 15 January 2003 (has links)
Orientador : Simonides Consani / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-02T20:41:10Z (GMT). No. of bitstreams: 1 Guimaraes_PriscillaSantos_D.pdf: 2015772 bytes, checksum: 3f7222b016b716845a6ac1634aeb1d81 (MD5) Previous issue date: 2002 / Resumo: O objetivo deste estudo foi verificar: 1) qual nível de energia que produziria o aspecto morfológico mais próximo do esmalte e dentina condicionados pelo ácido fosfórico no tecido dental irradiado por laser Er:YAG, por meio da observação ao microscópio eletrônico de varredura; 2) a resistência de união à tração de um sistema adesivo sobre superfícies de esmalte e dentina tratados com ácido fosfórico ou com laser Er:YAG, utilizando a energia estabelecida na observação morfológica. Para esta observação foram utilizados quatro terceiros molares humanos hígidos, extraídos por razões ortodônticas, que tiveram suas coroas separadas das respectivas raízes e então, seccionadas ao meio, no sentido mésio-distal. As superfícies vestibulares em esmalte, foram irradiadas com laser Er:Y AG, sob refrigeração com água, em sete pontos de incidência. Foram utilizados os seguintes níveis de energia, para cada ponto irradiado: 60, 100, 160, 200, 300, 400 e 500 mJ. A superfície lingual dos dentes foi preparada com pontas diamantadas em alta rotação, sob refrigeração, até exposição da dentina, sendo em seguida irradiada da mesma forma descrita. Decorridas 48 horas após a irradiação, as amostras foram metalizadas e observadas ao microscópio eletrônico de varredura. Para o ensaio de resistência de união foram utilizados 40 terceiros molares humanos hígidos, que tiveram suas raízes seccionadas e as coroas foram incluídas em resina acrílica ativada quimicamente em cilindros de plástico, com 20 mm de diâmetro externo por 20 mm de altura, com a face oclusal voltada para cima. Os cilindros de resina contendo as porções dentárias foram separados aleatoriamente em quatro grupos de 10 amostras cada, de acordo com o tipo de tecido e de condicionamento a ser empregado. Em seguida, as amostras foram desgastadas em politriz horizontal com lixas d'água de granulação 220, 400, 600, 800 e 1000. As superfícies das amostras foram examinadas em lupa estereoscópica, para assegurar que na região de teste só houvesse esmalte ou dentina expostos, dependendo do grupo experimental ao qual pertencem. A obtenção dos corpos-de-prova para o ensaio de tração foi realizada com um dispositivo, preconizado pela ISO, visando um perfeito alinhamento durante o procedimento de união. Os grupos 1 e 3 tiveram suas superfícies condicionadas com laser Er:Y AG com potência de 100 mJ, selecionada a partir dos resultados obtidos na observação morfológica; e as amostras dos grupos 2 e 4 foram condicionadas com ácido fosfórico a 35%, por 15 segundos. O sistema adesivo empregado para todos os grupos foi o Single-Bond (3M) e a resina Z-250 (3M), de acordo com instruções do fabricante. O ensaio de tração foi realizado 24 horas após o procedimento de união, em máquina de ensaio universallnstron modelo 4411, à velocidade de 0,5 mm/min. Os resultados foram submetidos ao teste de Tukey em nível de 5% de probabilidade. O aspecto morfológico das amostras irradiadas com laser Er:Y AG com potência de 100 mJ por pulso, apresentou-se como o mais favorável para o procedimento de união com materiais resinosos, tanto em esmalte quanto em dentina. Os valores médios de resistência de união ao esmalte e dentina condicionados com laser Er:YAG foram estatisticamente inferiores (p<0,05) àqueles obtidos para o condicionamento com ácido fosfórico. Os valores médios de resistência de união ao esmalte foram estatisticamente superiores àqueles para o tecido dentinário (p<0,05), independente do tipo de condicionamento utilizado / Abstract: The purpose of this study was to verify: 1) the energy levei that could produce the morphologic aspect similar to dental tissues conditioned with phosphoric acid on dental tissues irradiated by Er:Y AG (Yttrium aluminium gamet Y ~L5012) laser; 2) the tension bond strength of an adhesive system applied over enamel and dentin, after pretreatment with phosphoric acid or Er:YAG laser, using the energy levei established on the morphologic analysis. Four third human molars, extracted for orthodontic reasons, were used to make the morphologic analysis. The teeth had their crowns separated from the roots and than, each crown were sectioned in two. The buccal surfaces in enamel, were irradiated with Er:YAG laser, under water cooling, in seven different spots. The following energy levels were used for each spot of irradiation: 60, 100, 160, 200, 300, 400 and 500 mJ. The lingual dental surfaces were prepared with diamond burs, under water cooling, in order to expose dentin substrate, and afterwards were irradiated in the same way described for enamel. After 48 hours, the samples were sputtered with gold and observed under scanning electron microscope. For the tension bond strength test, 40 third human molars had their crowns separated from the roots and were than included in auto activated acrylic resin in plastic cylinders, with 20 mm in outside diameter by 20 mm high, with the occlusal surface facing up. The resin cylinders with the dental portions were randomly separated in four groups of 10 samples each, according to the dental tissue and conditioning method to be used. After, the samples were polished, under water, in a horizontal polishing machine with sandpaper 220, 400, 600, 800 and 1000 grito The samples surfaces were examined under esthereoscopic lens, to assure that on the test region would be exposed only enamel or dentin, depending on the experimental group they belong. In order to obtain the samples for the tension bond strength test, a device idealized by ISO were used, with the purpose of getting a perfect alignment during the bonding procedure. Groups 1 and 3 had their surfaces irradiated with Er:Y AG laser, energy levei of 100 mJ, chosen from the results obtained in morphologic analysis; and the samples of groups 2 and 4 were conditioned with 35% phosphoric acid, for 15 seconds. The adhesive system used, for ali test groups, was Single Bond (3M) and the resin 2-250 (3M), according to manufacturer's instructions. The tension bond strength test was realized 24 hours after the bonding procedure, in a universal test machine Instron model 4411, with a cross head speed of 0,5 mm/min. The results were submitted to Tukey's test at a significance levei of p<0.05. From the results, the mean values of bond strength to enamel and dentin irradiated with Er:Y AG laser were statistically lower (p<0.05) than those for phosphoric acid conditioning. The mean values of bond strength to enamel were statistically higher (p<0.05) compared with dentin, no matter which type of conditioning method used. / Doutorado / Doutor em Materiais Dentários
14

Avaliação de tecnicas para inserção da resina composta e da utilização de um composito de baixa viscosidade na resistencia de união a parede gengival de cavidades classe II

Reis, Andre Figueiredo 03 August 2018 (has links)
Orientador : Marcelo Giannini / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-03T08:31:11Z (GMT). No. of bitstreams: 1 Reis_AndreFigueiredo_M.pdf: 27890848 bytes, checksum: 0ebc10d01fd7a4da9c97f26cca6fe9b5 (MD5) Previous issue date: 2003 / Mestrado
15

Efeito da associação composito-materiais resilientes sobre a resistencia da união dentina/composito em modelos experimentais bi e tridimensionais

Santos, Alex Jose Souza dos 15 December 2003 (has links)
Orientador: Jose Roberto Lovadino / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-03T22:58:40Z (GMT). No. of bitstreams: 1 Santos_AlexJoseSouzados_D.pdf: 5116499 bytes, checksum: f65e728e88daf4b8db91116fb4821145 (MD5) Previous issue date: 2003 / Resumo: O objetivo deste estudo foi avaliar o efeito do tipo de compósito e da camada elástica sobre a resistência da união dentina/compósito em modelos bi e tridimensionais. O esmalte oclusal de 96 molares humanos foi removido expondo a superfície plana de dentina na qual foram preparadas cavidades Classe I (Fator C = 4,5; dimensões= 4 mm M-D, 3 mm V -L e 3 mm de profundidade). Dezoito grupos experimentais (n=4) foram distribuídos pela combinação de três compósitos: SureFil, Filtek Z250 e Z100; e de seis diferentes camadas elásticas: 1- SB(lc), camada única do adesivo Single Bond; 2- SB(3c), três camadas do adesivo Single Bond; 3- SB+SBMP, uma camada de SB associada a duas camadas adicionais do adesivo Scotchbond Multi Purpose; 4- OS, aplicação de uma camada do adesivo OptiBond Solo Plus; 5- SB+PLF, uma camada de SB associada ao compósito de alto escoamento Protect Liner F; e 6- SB+FF, uma camada de SB associada ao compósito de alto escoamento Filtek Flow. Cada camada adicional de adesivo foi fotoativada separadamente. Após a criação da "camada elástica", o compósito foi inserido em incremento único. Seis grupos adicionais foram obtidos a partir da união do compósito Esthet-X à parede livre de dentina vestibular (Fator C= 0,22; contração efetiva), seguindo os mesmos seis tipos de "camada elástica" realizados no modelo cavitário. As amostras foram armazenadas em água destilada a 37°C, por 24 h, antes do teste de tração. Os dentes foram preparados para microtração realizada numa máquina de ensaio universal (Instron 4411). Foram obtidos 4 palitos de cada dente (A _ 0,8 mm2), removidos da parede dentinária vestibular e testados a velocidade de 0,5mm/min. Os dados foram analisados pela análise de variância ANOV A e as médias de resistência de união (MRU) comparadas pelo teste de Tukey e Teste Dunnett ao nível de 5'0 de significância. As MRU variaram entre 11,2 e 29,6 MPa. Foi verificada diferença estatística entre as MRU para os diferentes compósitos (p= 0,0079) e entre as diferentes camadas elásticas tanto em cavidade (p< 0,0001) quanto parede-livre (p= 0,0095). O compósito Z250 apresentou, de forma geral, as maiores MRU com diferenças estatísticas daquelas apresentadas pelo compósito Z100. O compósito SureFil obteve resultados intermediários, sem diferenças estatísticas dos outros dois. No modelo cavitário, as MRU para o Z250, Z100 e SureFil foram respectivamente: SB+SBMP (27 / 22,9 / 20,4)a, SB+PLF (19,8 / 21,3 / 18,5)ab, SB+FF (21,3 / 19 / 15,4)bC, SB-3c (17,9 / 16,4 / 14,2)bC, 05-1 c (15,9 / 14,2 / 16)bC e SB-1c (17 / 14,8 / 11, 2)C . Os valores de resistência de união foram menores quando produzidos num modelo cavitário e dependentes do tipo de compósito e "camada elástica" formada. A associação do compósito Z250 às "camadas elásticas" SB+SBMP, SB+PLF, SB+FF e SB(3c) e a associação do compósito SureFil a SB+PLF foram capazes de produzir MRU, no modelo cavitário, semelhantes estatisticamente àquelas desenvolvidas quando o compósito foi submetido à "contração efetiva". Conclui-se que a utilização de compósitos de baixa viscosidade e de camadas espessas de adesivo, como camada intermediária, pode funcionar como uma zona de absorção de tensões, preservando a união e promovendo aumento dos valores de resistência da união dentina/compósito em cavidades Classe I / Abstract: T he aim of this in vitro study was to assess the effect of different { resin composites and elastic layers on resin/dentin bond strength on " the buccal wall of Class I cavities. Ninety-six caries-free third molars were ground flat to expose the dentin surface under running water. Class I cavities (C-factor = 4.5, 4 mm mesial-distal, 3 mm buccal-lingual and 3 mm deep) were prepared in occlusal dentin and then randomly distributed into eighteen experimental groups by changing of three resin composites (SureFil, Filtek Z250 e Z100) and six elastic layers: 1SB(lc), Single Bond adhesive was applied of according manufacturer instruction's; 2- SB(3c), Single Bond adhesive received two additional coats; 3- SB+SBMP, Single Bond adhesive received two additional coats of Scotchbond Multi-Purpose adhesive; 4- OS(lc) Optibond Solo Plus adhesive was applied of according manufacturer instruction's; 5- SB+PLF, Single Bond adhesive received intermediate layer of low-viscosity composite Protect Liner F; and 6- SB+FF, Single Bond adhesive received intermediate layer of low-viscosity composite Filtek Flow. Each additional adhesive layer was individually light-cured. After created elastic layer, the composite was placed using a bulk-filling increment. The teeth were prepared for microtensile bond strength (IlTBS) with the bonded beams (of approximately 0.8 mm2) obtained from the buccal wall of the cavity. The samples were stored in distilled water at 37°C for 24 h prior to IlTBS Testing. For each elastic layer, one additional group was accomplished to measure the bond strengths on corresponding buccal flat surface by cutting away the rest of the cavity walls (C-factor = 0.22). The data were analyzed using one and two-way ANOV A, Tukey Test for multiple comparisons and Dunnett's Test, at a significance levei of 0.05. The characteristic strength (TBSO) in this study varied about 11.2-29.6 Mpa. Statistical significant differences were verified among the resin composites (p = 0.0079) and among the various elastic layers in both cavity bonding groups (p< 0.0001) and flat bonding groups (p = 0.0095). The Z250 resin composite showed the higher TBS means, with statistical differences of the Zl00. The SLirefil groups exhibited comparable TBS means to others two composites. In the cavity bonding groups, the TBS values for Z250, Z100 and Surefil were respectively: SB+SBMP (27, 22.9, 20.4)a, SB+PLF (19.8, 21.3, 18.5)ab, SB+FF (21.3, 19, 15.4)bC, SB-3e (17.9, 16.4, 14.2)bc, OS-1e (15.9, 14.2, 16)bc and SB-1e (17, 14.8, 11.2)C. The mean bond strengths obtained in eavity bonding group were significantly lower than those of the flat bonding group, exeept when the Z250 resin eomposite was associate with SB+SBMP, SB+PLF, SB+FF and SB(3e) and the Surefil resin eomposite was associate with SB+PLF. This association provides the best bond strengths in eavity, similar to the bonding on a flat eavity. The TBS means are dependent of the eomposite and the various formed elastie layer. The use of a low-viseosity eomposite or multiple applieations of adhesive as intermediate layer ean provide a stress absorbing layer, whereby inereasing the resin/dentin bond strength in box-shaped eavities / Doutorado / Dentística / Doutor em Clínica Odontológica
16

Influencia da escovação mecanica sobre a infiltração marginal de restaurações de amalgama de prata associadas a agentes resinosos e condensadas com diferentes metodos

Berger, Roberta da Silva Nunes 21 July 1999 (has links)
Orientador: Mario Alexandre Coelho Sinhoreti / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-25T02:26:41Z (GMT). No. of bitstreams: 1 Berger_RobertadaSilvaNunes_M.pdf: 4696200 bytes, checksum: 020b7353feec458b48987963e3977e5d (MD5) Previous issue date: 1999 / Resumo: o objetivo deste estudo foi avaliar a infiltração marginal de restaurações de amálgama de prata confeccionadas com diferentes métodos de condensação, associadas ou não a diversos agentes resinosos e submetidas ou não à escovação. Para isso utilizou-se 144 dentes molares e pré-molares, divididos em 18 grupos de 8 dentes cada, nos quais foram confeccionadas cavidades classe V (2 mm de profundidade x 3mm de extensão mésio-distal x 1,5 mm de extensão oc1uso-cervical) nas superfícies vestibulares. As cavidades foram restauradas com a liga encapsulada Duralloy (Degussa, SI A) através de 3 maneiras: somente com amálgama de prata ( controle); amálgama associado ao sistema de união Scotchbond Multi-Uso Plus (3M); e amálgama associàdo ao Scotchbond Cimento Resinoso (3M). O amálgama foi condensado utilizando 3 técnicas: manual, mecânica e ultrassônica. Após restauradas e polidas, metade das amostras foram submetidas à escovação mecânica (30.000 ciclos) utilizando uma máquina de escovação Equilabor. Após, todas amostras foram termocicladas 500 vezes, sendo em seguida imersas em solução de azul de metileno a 2% por 4 horas. Os dentes foram seccionados para análise da infiltração e analisados numa lupa estereoscópica (63X). Foi utilizada também microscopia eletrônica de varredura para observação da margem dente-restauração. Os resultados foram analisados estatisticamente, aplicando o teste exato de Fisher. De acordo com os resultados obtidos, conclui-se que de um modo geral as restaurações de amálgama associadas à agentes resinosos apresentaram menor nível de infiltração. Quando realizou-se o pFocedimento de escovação mecânica, nenhum grupo foi influenciado, com exceção do grupo restaurado com amálgama associado ao Scotchbond Multi-Uso Plus com condensação mecânica, que apresentou maior nível de infiltração marginal, quando escovado. As fotomicrografias eletrôRicas de varredura mostraram que nos grupos escovados mecanicamente houve formação de valamento na margem dente/restauração / Abstract: The object of this study was to evaluate the marginal leakage of amalgam restoration associated or not to resinous agents, when they are submitted to brushing using differents resinous agents and differents condensation methods. With this purpose, 144 molar and pre-molar teeth were used and divided into 18 groups of 8 teeth each. Class V cavities preparation (2mm of deep x 3mm of length x 1,5 mm of width) were performed on buccal surface. The cavities were filled with Duralloy capsuled silver alloy (Degussa, SI A) by following different ways: only silver amalgam (control); amalgam associated with SBMU Plus (3M) adhesive system and amalgam associated to the Scotchbond Resin Cement (3M). The amalgam was condensed using 3 differehts technics: manual, mechanic and ultrasonic. After restored and polished, half ofthe samples were submitted to the mechanic brushing (30.000 cycles) using a Equilabor machine and after thermocycled to 500 times, being also immersed into 2% metilene blue solution for microleakage analysis and examined in a stereoscopic loupe (63x). Scanning electronic microscopy was used to analyse the toothlrestoration margin. The results were statistically analysed applying Fisher exact test. According to the results obtained we can conclude that generally, the amalgam restoration associated to resinous agents showed the smaller leveI of microleakage. When the mechanic brushing procedure was performed, any group was influenced, except the group restored with amalgam associated to SBMU Plus with mecharnc condensation, which showed the greatest leveI of microleakage, when brushed. The scanning electronic photomicrography showed that in groups mechanically brushed, noted a gap in the tooth/restoration margin / Mestrado / Materiais Dentarios / Mestre em Ciências
17

Eficácia do uso de ácido fosfórico modificado com proantocianidina na resistência de união de sistemas adesivos simplificados

Collyer, Jamilly Carneiro 28 March 2018 (has links)
Made available in DSpace on 2019-03-30T00:26:44Z (GMT). No. of bitstreams: 0 Previous issue date: 2018-03-28 / Proanthocyanidin (PA) has a proven beneficial effect on the longevity of dentin restorations, with the proposal of simplifying operative steps in a physical conditioning network, avoiding the addition of additional steps. Forty human molars were sectioned by exposing medium dentin and divided into four groups (n = 10) according to the conditioning and adhesive strategy: G1 - 35% phosphoric acid for 15s with Adper Single Bond 2 (SB - 3M ESPE); G2 - 10% phosphoric acid + 2% proanthocyanidin for 30 seconds with SB (3M ESPE); G3 - 35% phosphoric acid for 15s with Universal Single Bond (SBU - 3M ESPE); and G4 - 10% phosphoric acid + 2% proanthocyanidin for 30 seconds with SBU (3M ESPE). It was then made onto a nutrient surface with a composite resin substrate (Filtek Z250 - 3M ESPE). After 24h of storage in distilled water, the specimens were sectioned to obtain resin-dentin sticks (1 mm square cross-sectional area) and subjected to the microtensile test (0.5 mm / min). Statistical analysis was performed through ANOVA and unpaired ttest for analysis between adhesives (¿ = 0.05). The two groups of fractures of each group were observed in scanning electron microscopy (SEM). It was not possible to make the difference between the bands for the values of immediate resistance (p = 0.626). At the same time, the type of adhesive filter, changing only the challenge of overcoming the needs, is difficult to observe (p = 0.146; p = 0.779, for SB and SBU). The effect of phosphoric acid containing 2% proanthocyanidin did not impair the bond strength of immediate treatment to dentin. / A proantocianidina (PA) apresenta ação benéfica comprovada na longevidade de restaurações em dentina, entretanto a necessidade da simplicação de passos operatórios tem gerado a busca da associação de PA a condicionantes de superfície, evitando o acréscimo de passos adicionais. Quarenta molares humanos foram seccionados expondo dentina média e divididos em 4 grupos (n=10) de acordo com a estratégia de condicionamento e adesivo: G1- ácido fosfórico 35% durante 15s com Adper Single Bond 2 (SB - 3M ESPE); G2 ¿ ácido fosfórico a 10% + proantocianidina a 2% durante 30s com SB (3M ESPE); G3 ¿ ácido fosfórico a 35% durante 15s com Single Bond Universal (SBU - 3M ESPE); e G4 ¿ ácido fosfórico a 10% + proantocianidina a 2% durante 30s com SBU (3M ESPE). Em seguida, foi confeccionado sobre a superfície adesiva dos espécimes um platô em resina composta (Filtek Z250 ¿ 3M ESPE) medindo 4mm e armazenados em água destilada. Após 24h de armazenamento, os espécimes foram seccionados em forma de palitos (de 1 mm² de área de secção quadrada) e submetidos ao teste de microtração (0,5 mm/min). A análise estatística foi realizada através dos testes de ANOVA e teste t não-pareado para análise entre adesivos (¿=0,05). Dois dos espécimes fraturados de cada grupo foram observados em microscopia eletrônica de varredura (MEV). Não houve diferença estatística entre os grupos quanto aos valores de resistência de união imediata (p=0,626). Ao se avaliar individualmente o tipo de sistema adesivo, alterando-se apenas o tratamento da superfície pelo condicionante, também não foi observado diferenças (p=0,146; p=0,779, respectivamente para SB e SBU). O tratamento com ácido fosfórico a 10% modificado contendo 2% de proantocianidina não prejudicou a resistência de união imediata em dentina.
18

Avaliação da resistência adesiva de sistemas adesivos ao esmalte clareado de dentes bovinos sob teste de microtração

Deucher, Camila January 2014 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde, Programa de Pós-Graduação em Odontologia, Florianópolis, 2014. / Made available in DSpace on 2014-08-06T18:02:16Z (GMT). No. of bitstreams: 1 326596.pdf: 70286873 bytes, checksum: 1a3f6a5a37119122f45b0181d91a596e (MD5) Previous issue date: 2014 / Objetivos: Este estudo teve como objetivo avaliar a resistência de união sob teste de microtração ao esmalte clareado utilizando diferentes sistemas adesivos após o tratamento clareador. Material e métodos: Para isso utilizou-se a face vestibular de 30 incisivos bovinos, que foram divididos em 6 grupos: em G1, G2 e G3 não submetidos ao clareamento e G4, G5 e G6 submetidos ao clareamento com peróxido de carbamida 10% (Power Bleaching, BM4) por 1 mês (2 h/dia). Em seguida os dentes foram restaurados com resina composta utilizando os seguintes sistemas adesivos: em G1 e G4 utilizou-se o adesivo Prime&Bond; enquanto em G2 e G5 Gluma2; já em G3 e G6 o adesivo Clearfill SE BOND, sendo escolhidos com base no solvente. Após 24 horas armazenados em água, obtiveram-se palitos (0,9 mm2) através de cortes seriais e transversais, e submetidos ao teste de microtração (0,5 mm/s). Resultados: A análise estatística demonstrou diferença significante da resistência de união entre o esmalte clareado e não clareado. Além disso, o adesivo Prime&Bond mostrou resistência de união média superior aos demais adesivos. A análise da interação entre o tratamento de superfície e o adesivo utilizado mostrou maior resistência adesiva em esmalte não clareado em Prime&Bond e Gluma2. Entretanto, Gluma2 obteve os valores mais baixos no esmalte clareado. Prime&Bond e Clearfill SE BOND apresentaram valores semelhantes em esmalte clareado, sendo que Clearfill SE BOND não obteve diferença quando comparado o esmalte clareado ao não clareado. Conclusão: O tratamento clareador influenciou negativamente a resistência adesiva à microtração, estando dependente do sistema adesivo utilizado.
19

Influência da contaminação da dentina radicular sobre a resistência de união de um cimento resinoso autoadesivo

Costa, Débora Delai January 2015 (has links)
Dissertação (mestrado) - Universidade Federal de Santa Catarina, Centro de Ciências da Saúde, Programa de Pós-Graduação em Odontologia, Florianópolis, 2015. / Made available in DSpace on 2015-10-06T04:08:19Z (GMT). No. of bitstreams: 1 334488.pdf: 1682376 bytes, checksum: 4e5434064afa33ae9d37dc010953e4bd (MD5) Previous issue date: 2015 / O objetivo desta pesquisa foi determinar a resistência de união (RU) de um cimento resinoso autoadesivo à dentina radicular humana contaminada. Foram selecionados 20 dentes humanos unirradiculados, os quais tiveram suas coroas e terços apicais seccionados com um disco diamantado em baixa velocidade e sob refrigeração constante, resultando em segmentos de aproximadamente 8 mm. Os canais foram alargados com uma broca de preparo para pino número 2 em baixa rotação (Exacto, Angelus, Londrina, PR, Brasil). Em seguida, foram obtidas 6 secções radiculares de aproximadamente 1mm (3 do terço cervical e 3 do terço médio) em uma máquina de cortes de precisão (Isomet 1000, Buehler, Lake Bluff, IL). As secções foram inseridas individualmente em tubos Eppendorf identificados, e imersas, seqüencialmente, em solução de EDTA 17% por 3 min e NaOCl 1% por 3 min, lavadas, secas com gaze, e esterilizadas em autoclave. O grupo controle foi composto por uma secção de cada terço, as quais foram imersas em TSB estéril por 60 dias (n = 40). Para compor o grupo experimental, as demais secções foram imersas em meio TSB + sacarose 0,4% contendo 108 UFC/mL de E. faecalis por 60 dias, e o meio de cultura foi renovado a cada 4 dias (n = 80). Após o período experimental, as amostras foram lavadas com água destilada, secas com gaze e cones de papel absorvente, e o espaço referente ao canal radicular foi preenchido com o cimento resinoso autoadesivo Rely X U200 (3M/ESPE, St. Paul, MN, USA) conforme as recomendações do fabricante. Após 24h foi realizado o teste push out. Os dados foram analisados estatisticamente pelo teste de Mann-Whitney, com um nível de significância de 5%. O grupo experimental apresentou redução significativa na RU quando comparado com o grupo controle nos dois terços avaliados (p<0,05). Na comparação entre terços, no grupo experimental o terço cervical apresentou maior média de RU (p<0,05). Considerando as limitações deste estudo ex vivo, a contaminação bacteriana influenciou negativamente na RU do cimento resinoso autoadesivo à dentina radicular humana.<br> / Abstract : The aim of this study was to evaluate ex vivo the bond strength (BS) of a self-adhesive resin cement to human root dentin contaminated through the push out test, and evaluate the pathern of failure that occurred after the test. Twenty single-rooted human teeth had their crowns and apical thirds sectioned with a diamond disk at low speed and under constant cooling, to obtain segments of approximately 8 mm. The root canals have been extended with a #2 drill at low rpm (Exacto, Angelus, Londrina, PR, Brazil). Six root sections of 1 mm thickness were obtained (3 from the cervical third and 3 from the middle third) on a precision cutting machine (1000 Isomet, Buehler, Lake Bluff, IL). The sections were inserted in labeled Eppendorf tubes and immersed in 17% EDTA solution for 3 min followed by 1% NaOCl for 3 min, washed, dried with gauze and sterilized. The control group was composed by one section of each third, which were immersed in sterile TSB for 60 days (n = 40). To make the experimental group, the other sections were immersed in TSB medium containing 0.4% sucrose + 108 CFU/mL of E. faecalis for 60 days, and the culture medium was renewed every 4 days (n = 80). After the trial period, the samples were washed with distilled water, dried with gauze and absorbent paper points, and the space related to the root canal was filled with self-adhesive resin cement Rely X U200 (3M / ESPE, St. Paul, MN, USA) according to the manufacturer's instructions. The push out test was performed after 24h. Data were statistically analyzed using the Mann-Whitney test, with a 5% significance level. The experimental group showed a significant reduction in the BS when compared to the control group in both thirds evaluated (p<0.05). When comparing thirds, in the cervical third the experimental group showed higher mean of BS (p<0.05). Considering the limitations of this ex vivo study, bacterial contamination caused damage in self-adhesive resin cement BS to human root dentin.
20

Dentina hibridizada afeta a adesão do cimento resinoso autoadesivo?

Pamato, Saulo January 2014 (has links)
Made available in DSpace on 2016-11-30T14:53:36Z (GMT). No. of bitstreams: 2 110926_Saulo.pdf: 50165254 bytes, checksum: 1cbd8cfb1c609a3b37c6e61d474f074d (MD5) license.txt: 214 bytes, checksum: a5b8d016460874115603ed481bad9c47 (MD5) Previous issue date: 2014 / Os cimentos resinosos são compósitos resinosos de baixa viscosidade indicados na retenção e selamento marginal de restaurações indiretas, diferindo entre si de acordo com o pré-tratamento proposto previamente a etapa de cimentação. Por sua vez, os cimentos resinosos autoadesivos surgiram no mercado exibindo características de um protocolo simples de aplicação, contrapondo-se a sensibilidade técnica dos demais cimentos resinosos adesivos. Este trabalho se propôs a avaliar a influência de diferentes técnicas de hibridização na adesão de um cimento resinoso autoadesivo. Para tal, 30 molares humanos hígidos, oriundos de um banco de dentes, foram divididos em 6 grupos (n=10). Os espécimes receberam 3 secções longitudinais possibilitando a inclusão dos cortes centrais em matrizes de PVC. Com exceção do grupo controle (G1), cada grupo recebeu um pré-tratamento dentinário distinto de acordo com as recomendações do fabricante: G2 - condicionamento ácido total com sistema de 3 passos (Optibond¿ FL, Kerr), G3 - condicionamento ácido total com sistema de 3 passos (Adper¿ Scotchbond¿ Multi- Purpose, 3M ESPE), G4 - condicionamento ácido total com sistema de 2 passos (Adper¿ Single Bond 2, 3M ESPE), G5 - sistema autocondicionante de passo único (Bond Force, Tokuyama), G6 - sistema universal (Single Bond Universal, 3M ESPE). Em seguida, todos os grupos receberam a cimentação de um cilindro de cimento resinoso autoadesivo (RelyX U200, 3M ESPE) confeccionado a partir de uma matriz de polipropileno. Na avaliação da resistência de união, os corpos de prova foram submetidos ao teste de microcisalhamento e avaliados de acordo com o padrão de fratura por meio de microscopia óptica. Os resultados foram submetidos ao teste de Kruskal-Wallis, sugerindo diferença estatística significativa entre os grupos (p=0,04), e Tukey para comparações múltiplas, apontando diferença estatística significativa entre G1 e G3 (p<0,05). Quanto à análise microscópica, constatou-se alta predominância de falhas adesivas, seguido de falhas mistas e coesivas em dentina. Considerando as limitações do presente estudo, conclui-se que o emprego de um protocolo prévio de hibridização dentinária é capaz de elevar os valores de resistência a união do cimento resinoso autoadesivo, principalmente frente a utilização do sistema Adper¿ Scotchbond¿ Multi-Purpose. / The resin cements are composte resin of the low viscosity indicated in retention and marginal sealing of indirect restorations, differing from each other in accordance with pre-treatment previously proposed to the cementation step. In turn, the self-adhesive resin cements come onto de market showing features of a simple application protocol, countering the technical sensivity of the others resin cements. This study aimed to evaluate the effect of different hybridization techniques in adhesion of a self-adhesive resin cement. For such, 30 human molars, coming from a teeth's bank, were divided into 6 groups (n=10). The specimens received 3 longitudinal sections allowing the inclusion of central cuts in PVC matrix. Except the control group (G1), each group has received a different dentin pretreatment according with to the manufacturer's recommendations: G2 - etch & rinse system with 3 steps (Optibond¿ FL, Kerr), G3 - etch & rinse system with 3 steps (Adper¿ Scotchbond¿ Multi- Purpose, 3M ESPE), G4 - etch & rinse system with 2 steps (Adper¿ Single Bond 2, 3M ESPE), G5 - self-etching system with only step (Bond Force, Tokuyama), G6 - universal system (Single Bond Universal, 3M ESPE). Then all groups received the cementing of a self-adhesive resin cement cylinder (RelyX U200, 3M ESPE) made from a polypropylene matrix. In the evaluation of bond strength, the samples were subjected to the microshear test and evaluated according to the fracture pattern by optical microscopy. The results were submitted to the Kruskal-Wallis test, suggesting a statistically significant difference between groups (p=0,04), and Tukey for multiple comparisons, indicating a statistically significant difference between G1 and G3 (p<0.05). As regard the microscopic analysis, it was verified high prevalence of adhesive failures, followed by mixed failure and cohesive in dentin. Giving the limitations of this study, it is concluded that the use of a previous protocol of dentin hybridization is able to raise the values of resistance the union of the self-adhesive resin cement, mainly when using the Adper¿ Scotchbond¿ Multi-Purpose system.

Page generated in 0.0831 seconds