• Refine Query
  • Source
  • Publication year
  • to
  • Language
  • 128
  • 13
  • 13
  • 13
  • 12
  • 12
  • 11
  • 5
  • 4
  • 2
  • 1
  • 1
  • 1
  • Tagged with
  • 132
  • 132
  • 59
  • 52
  • 39
  • 34
  • 31
  • 28
  • 28
  • 23
  • 17
  • 15
  • 15
  • 15
  • 15
  • About
  • The Global ETD Search service is a free service for researchers to find electronic theses and dissertations. This service is provided by the Networked Digital Library of Theses and Dissertations.
    Our metadata is collected from universities around the world. If you manage a university/consortium/country archive and want to be added, details can be found on the NDLTD website.
101

Influencia da resina composta de baixa viscosidade no selamento marginal em restaurações de composito odontologico

Pereira, Orlando 14 December 2000 (has links)
Orientador: Mario Fernando de Goes / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-07-27T11:05:31Z (GMT). No. of bitstreams: 1 Pereira_Orlando_M.pdf: 5241632 bytes, checksum: 0bf58133c3fbea4878e495c3b9e059d0 (MD5) Previous issue date: 2000 / Resumo: O objetivo deste estudo foi avaliar a infiltração marginal de restaurações confeccionadas com resina composta em cavidades classe V, com a interposição de resinas de baixa viscosidade entre o adesivo e a resina restauradora. Trinta e seis cavidades tipo classe V foram preparadas nas faces vestibular e lingual na região do limite melo-dentinário­cementário com a parede oclusal em esmalte e a cervical em dentina. As cavidades foram padronizadas em 3mm(±0,2mm) na altura e 3mm(±0,2mm) na largura por 2mm(±0,2mm) de profundidade. Utilizamos como materiais restauradores uma resina composta de média viscosidade, com seu respectivo sistema adesivo, e duas resinas de baixa viscosidade. As 36 cavidades foram divididas em 3 grupos. Os seguintes procedimentos foram executados: Grupo I - Condicionamento ácido, aplicação de Single Bond e restauração em incremento único com a resina Filtek Z 250; Grupo II Condicionamento ácido, aplicação de Single Bond, fotoativação, uma camada da resina de baixa viscosidade Flow-It, fotoativação e restauração com a resina Filtek Z 250; Grupo 111 - condicionamento ácido, aplicação do adesivo Single Bond, foto ativação, uma camada da resina de baixa viscosidade Protect Liner F, fotoativação e restauração com a resina Filtek Z 250. Os dentes foram armazenados em água destilada a 37°C por 24 horas. Após o processo de acabamento e polimento, as superfícies dentais foram protegidas com verniz para unha, com exceção de 1 mm da margem das restaurações e imersos em solução de nitrato de prata 50% por 24 horas sob total ausência de luz. Em seguida os dentes foram lavados e armazenados em solução fotográfica reveladora, por 12 horas sob luz visível. Em seguida, foram seccionados longitudinalmente. Cada secção foi polida com lixas d'água de granulação 320, 400, 600, 1000 e com pastas de diamante de 6, 3, 1, e % de micra. Em seguida, as secções foram posicionadas em lupa estereoscópica, onde foram mensurados o comprimento total de penetração do nitrato de prata na interface dente-restauração e o comprimento total da cavidade. A divisão entre as duas mensurações multiplicadas por 100 resultou nos valores percentuais de infiltração que foram submetidos ao teste de Kruskal-Wallis (p<0.05). Os valores médios resultantes foram: Grupo 1=21,11 %; Grupo 11=7,89%; Grupo 111=2,65%. O valor médio percentual apresentado pelo Grupo III foi inferior estatisticamente em relação aos valores apresentados pelo Grupo I e 11, que não apresentaram diferença estatística entre si / Abstract: This study aimed at evaluating the marginal leakage of resin composite restorations in Class V cavities, with low-viscosity resin interposition between the adhesive and the restorative resin. Thirty-six Class V cavities were prepared on the facial and lingual surfaces at the cemental-enamel-dentine junction so that the occlusal wall was in enamel and the cervical one in dentine. The cavities were patterned as 3mm (±0.2mm) high, and 3mm(±0.2mm) wide by a 2mm(±0.2mm) depth. For restorative materials, we have used a medium-viscosity resin composite, and its accompanying adhesive agent, and two low-viscosity resins. Ali of the 36 cavities were divided up into three groups. The following procedure was carried out: Group I - Etehing, Single Bond application and single-increment restoration with a Filtek Z 250 resin; Group II - Etching, Single Bond application, light curing, a low-viscosity resin layer (Flow-it), light curing, and restoration with a Filtek Z 250 resin; Group 111 - Etching, Single Bond adhesive application, light curing, a low-viscosity resin layer Protect Liner F, light curing, and restoration with a Filtek Z 250 resin. The teeth were stored in distilled water at 37°C for 24 hours. Following the finishing and polishing process, the dental surfaces were coated with nail varnish, except for 1 mm off the restoration margins and were immersed in 50% silver nitrate for 24 hours in total darkness. Then, the teeth were rinsed and stored in developing photographic solution, for 12 hours under visible light. After that, they were sectioned longitudinally. Each section was polished with 320, 400, 600, 1000 wet sandpaper and with 6, 3, 1, and 1/4 micra diamond paste. Then, the sections were placed in stereoscopic loupe, where the total length of the silver nitrate penetration at the tooth-restoration interface and the total length of the cavity were measured. The division between the two measurements multiplied by 100 resulted in the percentages of leakage which underwent the Kuskal-Wallis (p<0.05) test. The resulting mean values were: Group I = 21.11 %; Group II = 7.89%; Group III = 2.65%. The mean percentage value exhibited by Group III was statistically lower as compared to those displayed by Groups I and II, which did not exhibit statistical difference between them / Mestrado / Mestre em Materiais Dentários
102

Avaliação da adaptação marginal, resistencia de união e nanoinfiltração de restaurações indiretas utilizando a tecnica de selamento dentinario e cimento resinoso / Evaluation of marginal adaptation, bond strength and nanoleakage of indirect restorations using resin coating technique and resin cement

Correa Medina, Alberth David 12 August 2018 (has links)
Orientador: Mario Alexandre Coelho Sinhoreti / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-12T20:03:41Z (GMT). No. of bitstreams: 1 CorreaMedina_AlberthDavid_D.pdf: 2483854 bytes, checksum: 56098c8765561f8bf74fb59fa865130c (MD5) Previous issue date: 2009 / Resumo: As restaurações estéticas indiretas têm sido a opção de escolha no caso de cavidades extensas. No entanto, este tipo de restauração demanda um desenho de preparo muito mais invasivo, podendo levar a sensibilidade pós-operatória, assim como também, certa incompatibilidade entre o cimento resinoso e o adesivo. Na tentativa de solucionar estas limitações tem sido sugerida uma técnica chamada de "Resin Coating Technique" ou Técnica de Selamento Dentinário (TSD), que consiste em proteger a superfície exposta após o preparo com um sistema adesivo e sobre este é aplicado ou nao um "liner" (monômero hidrófobo ou resina composta de baixa viscosidade). A utilização desta técnica vem oferecendo bons resultados, embora, pouco se sabe referente à combinação apropriada entre adesivo e "liner" e a interação desta técnica com os diferentes tipos de cimento resinoso. Portanto, este estudo teve como objetivos avaliar a influencia de diferentes combinações da TSD, na adaptação marginal, resistência de união, nanoinfiltração de restaurações indiretas, e após de ter identificado a combinação mais apropriada para a TSD, foi avaliada a interação desta com os cimentos resinosos através dos testes de adaptação marginal e resistência de união. Para estes estudos foram avaliados as combinações de sistemas adesivos que utilizam o condicionamento acido prévio de 2 e 3 passos e adesivos autocondicionantes de 1 e 2 passos seguido da aplicação ou não aplicaçao de uma camada de "liner" (monômero hidrófobo/resina composta de baixa viscosidade). Nas combinações avaliadas os grupos que obtiveram menores resultados tanto para adaptação marginal e resistência de união foram as combinações que não utilizaram liner. O grupo adesivo autocondicionante de 2 passos/resina composta de baixa viscosidade apresentou maior resistência de união e menor grau de nanoinfiltração. No entanto, todas as combinações avaliadas de TSD não conseguiram evitar a desadaptação marginal e nanoinfiltração das restaurações. Referente ao comportamento desta combinação com diferentes tipos de cimento, foi avaliada a adaptação marginal e resistência de união de diferentes cimentos resinosos (autocondicionante, autoadesivo e de ativação química) obtendo como resultados que o grupo que obteve melhores valores de resistência de união foi o grupo que utilizou cimento autocondicionante, embora não houve diferença entre os cimentos no que se refere à adaptação marginal. Por tanto, pelos achados destes estudos conclui-se que para obter melhor adaptação marginal utilizando a TSD é necessária a aplicação de um liner. A combinação de sistema autocondicionante 2 passos/resina de baixa viscosidade obteve maiores valores de resistência de união e menor padrão de nanoinfiltração. O cimento resinoso autocondicionante mostra-se ser o mais compatível com a TSD. / Abstract: Indirect esthetic restorations have been considered an excellent restorative alternative for extensive cavities. However, this type of restoration demands a more invasive preparation, which may cause post-operative sensibility and incompatibility between resin cement and adhesive system. In attempt to minimize these limitations the Resin Coating Technique (RCT) has been proposed. This technique consists in protecting the exposed dentin after the cavity preparation with an adhesive, followed by the application or not application of a liner (hydrophobic monomer or low viscosity resin). The effectiveness of this technique was reported in several studies, however, little is known about the appropriate combination between adhesive and liner and the behavior of this RCT with different resin cements. Therefore, the aims of this study were: evaluate the influence of the combination of different materials used in the RCT on the marginal adaptation, bond strength and nanoleakage of indirect restorations and after identify the most appropriate combination for the RCT, was evaluated the behavior of this RCT with different resin cements using the marginal adaptation and bond strength tests. For these studies were evaluated etch and rise adhesive system (2 and 3 steps) and self-etch adhesives (2 and 1step) followed of the application of liner layer (hydrophobic monomer or low viscosity resin). In all evaluated combinations, the groups that showed low results in marginal adaptation and bond strength were the combinations that not used a liner. The group self etch 2 steps/flow composite resin, showed high bond strength and low nanoleakage. However, in all the restorations showed marginal disadaptation and nanoleakage, independent of the material combinations used for the resin coating. In the study about the interaction of the RCT with the type of resin cement (Self-etching, Self-Adhesive and Chemical Cure) evaluating marginal adaptation and bond strength, was obtained the highest bond strength for the Self-etch group, however, there is no difference between groups for marginal adaptation. So, within the limits of this study, it can be concluded that the use of a liner is necessary for a better marginal adaptation using the RCT. The combination of self etch 2steps/flow composite resin showed high bond strength and low nanoleakage. The self etch resin cement revealed high bond strength showing more compatibility with the RCT. / Doutorado / Materiais Dentarios / Doutor em Materiais Dentários
103

Avaliação da qualidade da união resina composta-dentina obtida pelo emprego de materiais/tecnicas que visam minimizar os efeitos da umidade dentinaria sobre a longevidade das restaurações adesivas / Evaluation of the quality of resin/dentin bonds obtained by using techniques/materiais that intent to minimize the effect of dentin wetness on the longevity of adhesive restorations

Silva, Safira Marques de Andrade e 12 December 2009 (has links)
Orientador: Marcela Rocha de Oliveira Carrilho / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-13T16:52:08Z (GMT). No. of bitstreams: 1 Silva_SafiraMarquesdeAndradee_D.pdf: 1576367 bytes, checksum: 1f6e7c3cd256a0690cb307270c1569c0 (MD5) Previous issue date: 2008 / Resumo: O objetivo geral desta pesquisa foi avaliar materiais e procedimentos empreendidos para incrementar a durabilidade das restaurações adesivas. Os objetivos específicos foram: 1) avaliar o efeito da aplicação de uma camada adicional de adesivo e de um agente de união com característica hidrofóbica e livre de solventes na permeabilidade da dentina hibridizada com adesivos convencionais de 2 passos; 2) avaliar os efeitos decorrentes da aplicação do oxalato de potássio na durabilidade da interface de união obtida com adesivos convencionais e 3) determinar se a aplicação prévia do oxalato de potássio na dentina condicionada interfere na dureza Knoop dos adesivos. No primeiro estudo, a permeabilidade dentinária foi mensurada utilizando-se um medidor automático de fluxo, antes e após a aplicação dos sistemas adesivos nas condições experimentais citadas. Os resultados mostraram que nenhum dos adesivos foi capaz de prevenir a passagem de fluidos através da sua estrutura polimerizada. Porém, a aplicação de uma camada de um agente de união hidrofobico e livre de solventes reduziu significantemente a permeabilidade da dentina hibridizada com adesivos convencionais de 2 passos. Já no segundo estudo, testes de resistência adesiva (RA) foram realizados 24 horas após o procedimento adesivo ou após 12 meses de armazenagem em água. Os espécimes foram preparados para observação em microscopia eletrônica de varredura para avaliação do modo de fratura. Os resultados mostraram que a associação do oxalato de potássio aos sistemas adesivos reduziu significantemente a RA dos mesmos. Após o período de armazenagem, a RA foi significantemente reduzida em todos os grupos. No entanto, esta queda foi significantemente menor para os grupos tratados com oxalato. Finalmente, no terceiro estudo, testes de dureza foram realizados em microdurômetro e expressos como dureza Knoop (KHN). Os resultados mostraram que a associação do oxalato de potássio aos sistemas adesivos convencionais reduziu a KHN inicial dos mesmos. / Abstract: The general aim of this study was to evaluate materials and techniques that are thought to increase the longevity of adhesive restorations. The specific aims of this study were: 1) to test whether the application of an extra layer of the respective adhesive or the application of a hydrophobic, non-solvated bonding agent would interfere on the permeability of dentin hybridized with two-step etch-and-rinse adhesives; 2) to test whether the pretreatment of acid-etched dentin with potassium oxalate gel has an effect on the durability of resin-dentin interface created with etch-and-rinse adhesives; and 3) to determine whether the hardness of etch-and-rinse adhesives is affected by the pretreatment of acid-etched dentin with potassium oxalate gel. In the first study, dentin permeability was measured with an automatic record device, before and after dentin surfaces were bonded with the adhesives in the cited experimental conditions. The results showed that none of the adhesives or experimental treatments was capable to block completely the fluid transudation across the treated dentin; however, the application of the hydrophobic nonsolvated bonding agent resulted in significant reductions in the fluid flow rate. In the second study, the resin-dentin bond strength of the adhesives was tested immediately (i.e. 24 hours) and after 12 months of storage. The results showed that the pretreatment of dentin with potassium oxalate affect negatively the baseline resin-dentin bond strength of dentin specimens. After storage, the bond strength of resin-bonded interfaces was significantly reduced for all tested groups. Nevertheless, the decrease in bond strength values was significantly lower for oxalate-treated specimens than for controls. Finally, in the third study, the specimens' hardness was determined with a hardness tester and express as Knoop Hardness (KHN). The results showed that the baseline KHN of the adhesives applied to acid-etched dentin pretreated with potassium oxalate was significantly lower than that exhibited by their respective controls. / Doutorado / Materiais Dentarios / Doutor em Materiais Dentários
104

Influencia da distancia da ativação dos sistemas adesivos autocondicionantes na resistencia de união e qualidade da hibridização em dentina e esmalte / Influence of ativation of self-etching adhesives systems on the microtensile bond strength and quality of hibrydization in dentin and enamel

Araújo, Cíntia Tereza Pimenta de, 1968- 13 August 2018 (has links)
Orientador: Luis Alexandre Maffei Sartini Paulillo / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-13T23:32:00Z (GMT). No. of bitstreams: 1 Araujo_CintiaTerezaPimentade_M.pdf: 14470662 bytes, checksum: 420baeb44476851c8227ac8405455a06 (MD5) Previous issue date: 2009 / Resumo: Os sistemas adesivos autocondicionantes apresentam alta concentração de água utilizada como solvente para ionização de monômeros ácidos. A presença do excesso deste solvente no adesivo aplicado ao tecido dental pode comprometer a formação da camada híbrida, como também interferir na polimerização dos monômeros, produzindo interfaces de união permeáveis. O uso de sistemas adesivos autocondicionantes em situações clínicas de preparos cavitários Classe II com caixas proximais profundas, apresenta além dos problemas relacionados à sua composição, a possibilidade de ter a qualidade de polimerização afetada pela distância da fonte de luz nas paredes mais profundas. Assim a proposta deste estudo foi avaliar a influência da distância da fonte de luz na resistência à união através da microtração e avaliar a qualidade de hibridização através da nanoinfiltração de nitrato de prata em sistemas adesivos autocondicionantes aplicados aos substratos de esmalte e dentina. Para a realização deste estudo foram utilizados 198 incisivos bovinos e três sistemas adesivos autocondicionantes, Clearfil Protect Bond, Clearfil Tri-S e One up Bond F Plus que foram aplicados em superfícies planas de esmalte e dentina. A fotoativação dos adesivos foi realizada nas distâncias de 0,5, 3 e 6 mm e após a polimerização dos adesivos foi confeccionado um bloco de resina composta TPH3 de 4 mm de altura. Os resultados de microtração mostraram que distância da fonte de luz não influenciou significativamente a resistência à união, entretanto a mesma foi dependente do sistema adesivo e do substrato, em que o adesivo de dois passos Clearfil Protect Bond-Kuraray apresentou melhor comportamento em todas as condições experimentais. Entre os substratos, o esmalte mostrou as maiores médias de resistência de união. A análise de variância revelou diferenças significativas de porcentagem de nanoinfiltração para os fatores em estudo sistema adesivo (p<0.0001), substrato dental (p=0,0001) e para as interações distânciaXsubstrato (P=0,0159) e adesivoXsubstrato (P=0,0079). Para a interação distânciaXsubstrato, não foram observadas diferenças significativas de nanoinfiltração entre os grupos fotoativados às distâncias de 3 e 6 mm nas interfaces em dentina, entretanto os mesmos apresentaram menor nanoinfiltração do que os grupos com 0,5 mm de distância de fotoativação. Assim pelos dados observados neste estudo pôde-se concluir que a distância da fonte de luz não influenciou a resistência à microtração dos sistemas adesivos e o padrão de nanoinfiltração das interfaces em esmalte. Por outro lado, o padrão de nanoinfiltração em dentina foi adversamente influenciada pela fotoativação às distâncias de 0,5 e 6 mm. / Abstract: The self-etching adhesives systems present high water content that are used as solvent for acid monomer ionization. The presence of the excess of this solvent in the hybrid layer can compromise its the formation, as well as to affect the polymerization of monomers producing bonding interfaces permeables. The use of self-etching adhesives in clinical situations of Class II cavities with deep box, presents beyond the problems related to its composition, the possibility to have the quality of polymerization affected for the distance of the source of light in the deepest walls. Thus the purpose of this study was to evaluate the influence of the light-tip distance of a halogen light-curing lights in the microtensile bond strength (MTBS) and to evaluate the quality of hybridization through the nanoleakage of self-etch adhesive systems applied to substrate of enamel and dentine. For the accomplishment of this study 198 bovine incisors and three selfetching adhesive systems were used, Clearfil Protect Bond, Clearfil Tri-S and One up Bond F Plus that were applied in plain surfaces of enamel and dentine. The photoactivation of the adhesives was carried through at 0,5, 3 and 6 mm distances and after a 4-mm thick TPH3 composite block was built. The results showed that distance of the light-guide did not influence significantly the MTS, however the same one were dependent of the adhesive system and substrate, where the adhesive of two steps Clearfil Protect Bond (Kuraray) presented better behavior in all experimental conditions. Between dentals substrate the enamel showed highest mean bond strength. For the nanoleakage analysis, the threeway ANOVA detected no significant difference for the distance of the lightcuring tip and significant differences for the adhesive (p<0.0001) and substrate (p<0.0001) factors, and the double interactions between distance X substrate (p=0.0159) and between adhesive X substrate (p = 0.0079) were also significant. For the interaction distance X substrate, no significant difference in nanoleakage was observed among groups light-activated with curing unit tip having a distance of 3 and 6 mm when the adhesive interfaces were in dentin. On the other hand, such groups showed lower nanoleakage than those with 0,5 mm distance between curing unit tip and the bonded surface. Thus for the data observed in this study it could be concluded that the distance of the light-guide did not influence the !TBS values of the adhesives systems and the nanoleakage patterns of the enamel interfaces. However, the nanoleakage patterns were adversely influenced by photoactivation at distances of 0,5 and 6 mm. / Mestrado / Dentística / Mestre em Clínica Odontológica
105

Efeito do digluconato de clorexidina na estabilidade da união de sistemas adesivos e dentina sadia ou afetada por carie / Effect of clorhexidine digluconate on the bond strength of etch-and-rinse adhesives to normal/caries-affected dentin

Komori, Paula Carolina de Paiva 15 February 2007 (has links)
Orientadores: Marcela Rocha de Oliveira Carrilho, Mario Fernando de Goes / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-08T07:24:11Z (GMT). No. of bitstreams: 1 Komori_PaulaCarolinadePaiva_M.pdf: 1172692 bytes, checksum: f270e64b5e17566b769c732de50975bf (MD5) Previous issue date: 2007 / Resumo: O objetivo deste trabalho foi avaliar o efeito da aplicação da solução aquosa de digluconato de clorexidina a 2% (CHX) na estabilidade da união de sistemas adesivos convencionais e dentina sadia (DS) ou afetada por cárie (DAC). Neste estudo foram testadas as hipóteses de que a CHX não teria efeito prejudicial na resistência de união entre DS ou DAC e que em longo prazo a CHX poderia minimizar o mecanismo de degradação da interface dentina-resina. Vinte molares humanos cariados tiveram o esmalte e dentina superficial removidos para exposição de uma superfície plana de DS e DAC. Os substratos foram condicionados com gel de ácido fosfórico 35% por 15s, lavados e secos com leve jato de ar. Os dentes foram distribuídos em dois grupos para o tratamento da superfície dentinária, o controle: foi re-umedecido com água deionizada; e o experimental: com CHX, a solução umidificadora permaneceu em contato com o substrato durante 60s e o excesso de umidade removido com papel absorvente. Sobre o substrato foi aplicado o adesivo Scotchbond Multi-Purpose (MP) ou Single Bond 2 (SB) e confeccionado um bloco com incrementos de resina composta Z-250. Após 7 dias de armazenagem em solução fosfato tamponada (PBS, pH 7,4) a 37ºC, as amostras foram submetidas a cortes seriados, gerando espécimes em forma de palitos com área de interface de união de aproximadamente 0,8mm2. Metade dos espécimes foi imediatamente submetida ao teste de microtração e a outra metade permaneceu armazenada por 6 meses. Os resultados obtidos foram submetidos à análise de variância e teste de Holm-Sidak para contraste das médias em nível de significância (a=0,05). A primeira hipótese testada foi confirmada, o uso da CHX após o condicionamento ácido não interferiu na resistência mecânica imediata da interface formada por um compósito de resina e DS ou DAC. A segunda hipótese foi parcialmente confirmada, o uso da CHX após o condicionamento ácido minimizou o processo de degradação das interfaces de união constituídas por DS. A utilização da CHX em associação aos sistemas adesivos convencionais de 2 e 3 passos durante a hibridização pode atuar como potencial agente retardador da degradação das interfaces adesivas promovendo maior longevidade às restaurações adesivas / Abstract: The aim of this study was to evaluate the effect of 2% chlorhexidine digluconate on the bond strength of etch-and-rinse adhesives applied to sound (SD) and caries-affected dentin (CAD). It is hypothesized that CHX does not have a detrimental effect on the bond strength to sound and caries-affected dentin, as well as that CHX may decelerate the mechanical degradation of resin-dentin bonds over time. Twenty, carious, extracted molars were included in this study. The occlusal enamel of all teeth was removed with a slowspeed diamond saw, under copious water-cooling, in order to expose a flat surface, where the CAD was surrounded by SD. The CAD and SD surfaces were etched with 35% phosphoric acid gel for 15 s, rinsed for 30 s with tap water and dried with oil/water-free air. In the control groups, the dentin substrates were re-hydrated with distilled water, while in the experimental groups were re-hydrated with 2 wt% chlorhexidine digluconate (CHX). After a dwell time of 60 s, excess solution was removed with absorbent paper. The dentin surfaces were then bonded with one of the etch-and-rinse adhesives, Schotchbond Multi- Purpose (MP) or Single Bond 2 (SB). Composite build-up was performed with Z250 and stored in phosphate-buffered saline (PBS, pH 7.4) at 37ºC for 7 days. After this period, the restored teeth were longitudinally sectioned across the bonded interface to produce a series of 0.8 mm2 beams. Part of those specimens was immediately subjected to a microtensile test. The remaining specimens were stored in PBS at 37°C for six months and then tested in tension under the same protocol. Data were analyzed by ANOVA and Holm-Sidak test for multiple comparisons (a = 0.05). The first anticipated hypothesis was confirmed, the use of CHX after acid-etching did not have detrimental effect on the immediate bond strength to both normal and caries-affected dentin and the second anticipated hypothesis was partially confirmed, the mechanical degradation of resin-dentin bonds may be delayed by the application of chlorhexidine (CHX) to sound dentin after phosphoric acid-etching. Attempts to use chlorhexidine adjunctively with conventional acid-and-rinse adhesives may play a clinically-relevant role on the preservation of resin-dentin bonds / Mestrado / Mestre em Materiais Dentários
106

Efeito do fluor de um sistema adesivo na resistencia de união e no desafio acido em dentina / Effect of fluoride containing adhesive system on microtensile bond strength and acid challenge on dentin

Shinohara, Mirela Sanae 28 February 2007 (has links)
Orientador: Mario Fernando de Goes / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-09T05:02:58Z (GMT). No. of bitstreams: 1 Shinohara_MirelaSanae_D.pdf: 3018873 bytes, checksum: 16d55d49d5fce271495b768e34d15abc (MD5) Previous issue date: 2007 / Resumo: Apesar do avanço na odontologia adesiva, não é possível conseguir uma união perfeita da resina composta ao substrato dental. Diversos são os adesivos dentinários atualmente presentes, mas nenhum é capaz de impedir a infiltração marginal, degradação e formação de cárie secundária na interface dente-resina ao longo do tempo. Dessa forma, como alternativa, o flúor foi incorporado a um adesivo com o objetivo de promover uma ação antibacteriana e impedir a formação de cárie secundária, conseqüentemente aumentar a longevidade da restauração. Portanto, este estudo teve como objetivos: (1) avaliar a influência do flúor presente no adesivo na resistência de união em dentina e analisar a estrutura da interface dente-adesivo após desafio ácido por meio de microscopia eletrônica de varredura (MEV); (2) avaliar a influência do flúor no adesivo na resistência de união em dentina após 24 horas e 3 meses de estocagem de água, observar a formação de uma zona ácido-resistente na interface dentina-resina após 24 horas e 3 meses de estocagem em água por meio de microscopia de luz polarizada (MLP), e comparar o grau de conversão do adesivo que contém flúor com dois adesivos sem flúor após 24 horas, 1 semana e 1 mês. Tanto para o teste de resistência à microtração, como para análise das interfaces: terceiros molares humanos hígidos recém-extraídos foram usados para realização das restaurações, de acordo com os grupos analisados em cada estudo específico. Para a análise do grau de conversão, pastilhas dos adesivos foram preparados em temperatura controlada e atmosfera de nitrogênio para análise de espectrofotômetria de infravermelho pela técnica transformada de Fourier em modo de transmissão (FTIR). Os resultados mostraram que o flúor presente no adesivo apresenta um efeito positivo na resistência de união, embora apresente menor grau de conversão comparado aos adesivos sem flúor. As imagens de MEV e MLP mostraram que o adesivo com flúor forma uma zona de inibição adjacente à camada híbrida após desafio ácido / Abstract: Despite of the advance in adhesive dentistry, it is not possible to achieve an ideal bonding between composite resin and dental substrate. Currently, a variety of adhesive systems have been used. However, any adhesive system is capable to hamper the marginal leakage, degradation, and secondary caries formation at dentin-resin interfaces in long-term. For that reason, as an alternative, fluoride was incorporated in adhesive in order to promote an antibacterial action and to impede the secondary caries formation, onsequently increasing the longevity of restoration. Thus, the objectives of this study were: (1) to evaluate the influence of a fluoride-containing adhesive on the microtensile bond strength (µTBS) in dentin, and to analyze the ultra-structure of the dentin-adhesive interface after acid challenge; (2) to evaluate the influence of fluoride-containing adhesive on µTBS after 24 hours and 3 months waterstorage; to observe an acid-resistant zone at resin-dentin interface using polarized light microscopy (PLM) after 24 hours and 3 months water storage, and to compare the degree of conversion of fluoride-containing adhesive with non-fluoride containing adhesives after 24 hours, 1 week, and 1 month. For both, to the µTBS test and to analyze the ultra-structure of interfaces: free-caries human third molars were used for restorations, in accordance with of the analyzed groups in each specific study. In order to measure the degree of conversion, chips of adhesives were prepared at a constant temperature and in a nitrogen atmosphere for the analysis at Fourier Transform-Raman spectroscopy (FTIR). The results showed that the present fluoride-containing adhesive has a positive effect in bonding strength, although the lower degree of conversion compared with non-fluoride adhesives. The photomicrographs of SEM and PLM demonstrated that fluoride-containing adhesive allow the formation of an inhibition zone adjacent to the hybrid layer after acid challenge / Doutorado / Materiais Dentarios / Doutor em Materiais Dentários
107

Desempenho clinico e mecanico de adesivo auto-condicionante a dentina decidua afetada por carie / Clinical and mechanical performance of self-etching adhesive to primary caries-affected dentin

Aratani, Monica 14 February 2007 (has links)
Orientador: Mario Fernando de Goes / Dissertação (mestrado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-09T19:07:57Z (GMT). No. of bitstreams: 1 Aratani_Monica_M.pdf: 1204814 bytes, checksum: 89f8098c0a4f04da2cbe17fab1476c17 (MD5) Previous issue date: 2003 / Resumo: O propósito deste trabalho foi estudar o efeito de métodos de contensão da mufla metálica (grampo convencional e sistema RS de contensão) e do tempo pós-prensagem (imediato e 6 horas) nos níveis de adaptação da base de prótese total superior confeccionada com as resinas acrílicas ativadas termicamente Clássico (Clássico) e QC-20 (Dentsply). Foram confeccionados 80 conjuntos modelo de gesso-base de cera distribuídos aleatoriamente em 8 grupos (n=10), de acordo com os métodos de contensão de mufla metálica e do tempo pós-prensagem. As resinas acrílicas foram proporcionadas e manipuladas de acordo com as instruções dos fabricantes e prensadas na fase plástica, com carga inicial de 850 kgf e final de 1250 kgf em prensa hidráulica de bancada. As bases confeccionadas em resina Clássico foram polimerizadas em ciclo de água a 74?C por 9 horas e as bases de resina QC-20 em água em ebulição por 20 minutos. Depois de esfriadas até atingir a temperatura ambiente, as bases foram desincluídas, acabadas, fixadas nos respectivos modelos de gesso com adesivo à base de cianoacrilato e seccionadas em três secções, correspondentes à distal de caninos, mesial de primeiros molares e região palatina posterior. Em cada secção, o desajuste entre modelo de gesso e base de resina foi verificado nos pontos referenciais fundo de sulco vestibular direito e esquerdo, crista do rebordo alveolar direito e esquerdo e linha mediana palatina posterior, com microscópio comparador linear Olympus, com precisão de 0,0005 mm. Os resultados coletados foram submetidos à análise de variância e ao teste de Tukey (5%). O dispositivo RS produziu níveis médios de adaptação com diferença estatística significante quando comparado com o grampo convencional, independente dos demais fatores. O dispositivo RS produziu níveis médios de adaptação nos tempos imediato e 6 horas com diferença estatística significante quando comparado com o grampo convencional. A polimerização imediata produziu valores entre cortes sem diferença estatística significativa quando comparada com a polimerização após 6 horas. Quando os cortes foram analisados no fator prensagem, os melhores níveis de adaptação foram obtidos com o dispositivo RS, com diferença estatística significativa quando comparado com o grampo convencional. Os tratamentos RS e convencional apresentaram comportamento semelhante, independente da resina, mas foram diferentes no tempo pós-prensagem. A região posterior apresentou maiores valores de desadaptação em ambas as resinas, independente do tipo de contensão da mufla e do tempo pós-prensagem / Abstract: The purpose of this study was to verify the effect of flask closure method (conventional clamp and RS tension system) and post-pressing time (immediate and after 6 hours) on the maxillary denture base adaptation made with Classico and QC-20 heat?cured acrylic resins. Eighty maxillary stone cast/wax base sets were made and randomly assigned into 8 groups (n=10) according to the flask closure method and post- pressing time. The acrylic resins were proportioned and manipulated following the manufacturer?s instructions and flask pressed in the doughlike stage with an initial load of 850 kgf and final load of 1,250 kgf in hydraulic press. Classico acrylic resin was submitted to polymerization in water at 74°C during 9 hours in immediate or after 6 hour post-pressing times. QC-20 acrylic resin was submitted to polymerization in boiling water for 20 minutes. After bench cooling the resin bases were deflasked, finished, and fixed on the casts with instantaneous adhesive. The cast-resin base sets were laterally sectioned in the regions corresponding to the distal of canines (A), mesial of first molars (B), and posterior palatal zone (C). The gap between the stone cast and resin base was measured with an Olympus comparative microscope with accuracy of 0.0005mm at five referential points for each section. Data submitted to ANOVA and Tukey?s test (5%) showed that the RS system produced medium levels of adaptation with statistically significant difference when compared to the conventional clamp, independent of the other factors. RS system produced levels of adaptation in the immediate and 6 hours post-pressing times with statistical significant difference when compared to the conventional clamp. The immediate polymerization produced values among cuts without statistical difference when compared to the polymerization after 6 hours. When the cuts were analyzed in the factor flask pressure method, the best levels of adaptation were showed with the RS system, with statistical significant difference when compared to the conventional clamp. The RS system and conventional clamp treatments showed similar results independent of the resin factor; however they were different in the post-pressing time. The posterior region showed greater values of desadaptation in both resins, independent of the flask closure method and post-pressing time / Mestrado / Doutor em Materiais Dentários
108

Efeito da aplicação de fosfopeptidio de caseina-fosfato de calcio amorfo (CPP-ACP) associada ao protocolo adesivo na resistencia de união de um selante de fossulas e fissuras / Effect of the casein phosphopeptide-amorphous calcium phosphate (CPP-ACP) associated to adhesive procedures on bond strength of a pit and fissure sealant

Borges, Boniek Castillo Dutra 15 August 2018 (has links)
Orientador: Flavio Henrique Baggio Aguiar / Dissertação (mestrado) - Universidade Estadual de Campinas. Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-15T16:07:16Z (GMT). No. of bitstreams: 1 Borges_BoniekCastilloDutra_M.pdf: 1684479 bytes, checksum: c40bc0507b501c53b9ecebcc18575278 (MD5) Previous issue date: 2010 / Resumo: O objetivo deste trabalho foi investigar, in vitro, o efeito da aplicação de uma pasta contendo fosfopeptídeo de caseína - fosfato de cálcio amorfo (CPP-ACP) (MI Paste - MI) previamente ao protocolo adesivo na resistência da união de um selante resinoso de fóssulas e fissuras ao esmalte dental humano. Foram utilizados 98 espécimes de esmalte proximal de terceiros molares totalmente erupcionados, divididos em 14 grupos experimentais (n=7): G1/G8- condicionamento ácido (CA) (Scotchbond Etchant), sem a aplicação de sistema adesivo; G2/G9- CA + resina hidrófoba de um sistema adesivo convencional de três passos (Scotchbond Multipurpose Plus); G3/G10- CA + sistema adesivo convencional de dois passos (Single Bond 2); G4/G11 - CA + sistema adesivo autocondicionante de passo único (Clearfil S3 Bond); G5/G12- CA + sistema adesivo autocondicionante de dois passos (Clearfil SE Bond); G6/G13- sistema adesivo autocondicionante de dois passos; G7/G14- adesivo autocondicionante de passo único. MI foi aplicada previamente ao protocolo adesivo apenas nos grupos de G1 a G7. Após selamento das superfícies (FluroShield), foram confeccionados blocos retangulares (palitos) (~0,7mm2 de área seccional) para o ensaio de microtração. O teste foi efetuado imediatamente após confecção das amostras por meio da Máquina de Ensaio Universal, na velocidade de 0,5 mm/min. Após, o padrão de fratura foi analisado por meio de Microscopia Eletrônica de Varredura (MEV). Os valores de resistência da união foram analisados por meio de ANOVA dois fatores com parcela subdividida. A aplicação da pasta contendo CPP-ACP previamente aos sistemas adesivos convencionais e àqueles autocondicionantes sem condicionamento ácido prévio aumentou os valores de resistência da união. Houve predomínio de fraturas mistas nos grupos que receberam MI Paste, ao passo que, naqueles em que não se aplicou MI Paste a maior prevalência foi de fraturas adesivas. O contato do esmalte com CPP-ACP anteriormente à aplicação dos sistemas adesivos é um método eficaz para aumentar a resistência de união entre esmalte e selantes de fóssulas e fissuras. / Abstract: This study evaluated the effect of applying a casein phosphopeptide-amorphous calcium phosphate (CPP-ACP) containing paste (MI Paste - MI) previously to adhesive procedures on the microtensile bond strength of a pit and fissure sealant to human enamel in vitro. Ninety eight fragments were obtained from proximal surfaces of totally erupted third molars. Specimens were divided into 14 experimental groups (n=7): G1/G8- phosphoric acid conditioning (PA) (Scotchbond Etchant) and no adhesive system; G2/G9- PA + hydrophobic resin of a three step adhesive system (Scotchbond Multipurpose Plus); G3/G10- PA + etch-and-rinse two-step adhesive system (Single Bond2); G4/G11- PA + all-in-one adhesive (Clearfil S3-Bond); G5/G12- PA + two-step self-etching adhesive system (Clearfil SE-Bond); G6/G13- all-in-one adhesive; G7/G14- two-step self-etching adhesive system. MI was applied on the enamel before adhesive strategies only for groups from G1 to G7. After sealing (FluroShield), beams with approximately 0.7 mm2 of sectional area were cut for microtensile test, which was executed trough a universal test machine at a speed of 0.5 mm/min. Fractured specimens were analyzed by scanning electronic microscopy to determine failure modes. Bond strength data was statistically analyzed by two-way ANOVA with subparcels. Groups which MI was applied on the enamel followed by sealant bonding with etching-and-rinse and self-etching adhesives without additional enamel acid etching presented higher means than other which MI was not applied. Higher frequency of cohesive failures was observed for groups with MI, while adhesive fractures were more prevalent in groups without MI. Applying a CPP-ACP containing paste before adhesive systems to the enamel is an effective method to increase bond strength of the sealant tested. / Mestrado / Dentística / Mestre em Clínica Odontológica
109

Influência da adição de nanopartículas de prata no efeito antibacteriano, na alteração de cor, na sorção e solubilidade de adesivos dentários / Influence of silver nanoparticles on the anbacterial effect, color change, sorption and solubility of dental adhesives

Moreira, Francine do Couto Lima 26 September 2013 (has links)
Submitted by Jaqueline Silva (jtas29@gmail.com) on 2014-12-16T09:39:30Z No. of bitstreams: 1 Tese-Francine de Couto Lima Moreira-2013.pdf: 2677699 bytes, checksum: 8dc4da322744f0e3a50d55d5b06493bc (MD5) / Rejected by Jaqueline Silva (jtas29@gmail.com), reason: on 2014-12-16T09:53:06Z (GMT) / Submitted by Jaqueline Silva (jtas29@gmail.com) on 2014-12-29T18:57:50Z No. of bitstreams: 2 license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) Tese-Francine de Couto Lima Moreira-2013.pdf: 2677699 bytes, checksum: 8dc4da322744f0e3a50d55d5b06493bc (MD5) / Approved for entry into archive by Jaqueline Silva (jtas29@gmail.com) on 2014-12-29T18:58:08Z (GMT) No. of bitstreams: 2 license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) Tese-Francine de Couto Lima Moreira-2013.pdf: 2677699 bytes, checksum: 8dc4da322744f0e3a50d55d5b06493bc (MD5) / Made available in DSpace on 2014-12-29T18:58:08Z (GMT). No. of bitstreams: 2 license_rdf: 23148 bytes, checksum: 9da0b6dfac957114c6a7714714b86306 (MD5) Tese-Francine de Couto Lima Moreira-2013.pdf: 2677699 bytes, checksum: 8dc4da322744f0e3a50d55d5b06493bc (MD5) Previous issue date: 2013-09-26 / Aim: to evaluate the influence of silver nanoparticles to antibacterial effect, color change, sorption, and solubility of dental adhesives. Material and methods: they were analised four groups of dental adhesives: SB - AdperTM Single Bond 2 without adding NAg, SM - AdperTM Scotchbond Multi-use without adding NAg; SBAg - SB with addition of 0.1% of NAg ; SMAG - SM with addition of 0.1% of NAg. One handred and thirty two specimens of the adhesives were prepared according to the standard of ISO 4049:2010, with circular geometry dimensions of 10mmx1mm. After different periods of specimens contamination with Streptococcus mutans (ATCC 25175) (1min; 5min; 1h; 6h, e 24h) the antimicrobial activity was observed by bacterial grouth (optical density), and the presence/absence of bacteria on the specimens surface by Scanning Electron Microscopy (2500x e 5000x). Also evaluated the color change of specimens after adding NAg through the CIELab system, and sorption and solubility tests (ISO 4049:2010) were performed to verify the polymeric quality of materials. Data were subjected to analysis of variance (ANOVA) followed by Tukey test for multiple comparisons, with p=0.05 for all tests, except for analysis of ΔE what underwent Pearson`s correlation (p=0.01). Results: there were no statistical differences between the values of optical density of the culture broth used to store the specimens contaminated with S. mutans, even with the addition of NAg (p>0.05). Both adhesives have significant change in color, after the addition of nanosilver in its composition (p<0.01). No statistical differences were observed on the values of sorption and solubility differences as the addition of NAg in studied adhesives (p>0.05). Conclusion: addition of 0.1% pure silver nanopowder in dental adhesive did not confer antibacterial effect to the material, cause material color changes and did not affect the values of sorption and solubility. / Objetivo: avaliar a influência da adição de nanopartículas de prata (NAg) no efeito antibacteriano, na alteração de cor, na sorção e solubilidade de adesivos dentários. Material e métodos: para tanto foram analisados quatro grupos de adesivos dentários: SB - AdperTM Single Bond 2 sem adição de NAg; SM - AdperTM Scotchbond Multi-uso sem adição de NAg; SBAg – SB com adição de 0,1% de NAg; SMAg - SM com adição de 0,1% de NAg. Cento e trinta e dois espécimes dos adesivos foram confeccionados segundo a norma da ISO 4049:2010, com geometria interna circular nas dimensões de 10mmX1mm. Após diferentes períodos de contaminação dos espécimes com Streptococcus mutans (ATCC 25175) (1min; 5min; 1h; 6h e 24h), o efeito antibacteriano foi analisado por meio de densidade óptica e a presença/ausência de bactérias na superfície dos espécimes por microscopia eletrônica de varredura (2500x e 5000x). Avaliou-se também a alteração de cor (ΔE) dos espécimes após a adição da NAg, utilizando espectrofotômetro com base no sistema CIELab. Os testes de sorção e solubilidade (ISO 4049:2010) foram realizados para verificar a qualidade polimérica dos materiais. Os dados obtidos foram submetidos a uma análise de variância (ANOVA), seguida pelo teste de Tukey, para comparações múltiplas, com p=0,05, para todos os testes, exceto para análise do ΔE que foi submetido à correlação de Pearson (p=0,01). Resultados: não foram observadas diferenças estatísticas entre os valores de densidade óptica dos meios de cultura utilizados para armazenar os espécimes contaminados com S. mutans, mesmo com a adição de NAg (p>0,05). Ambos os adesivos sofreram alteração de cor significante, posterior à adição da nanoprata em sua composição (p<0,01). Quanto aos valores de sorção e solubilidade não foram observadas diferenças estáticas quanto à adição de NAg nos adesivos estudados (p>0,05). Conclusão: a adição de nanopartículas de prata, pura, em pó a 0,1%, nos adesivos dentários não conferiu efeito antibacteriano ao material, causou alteração de cor e não interferiu nos valores de sorção e solubilidade dos mesmos.
110

Efetividade de antioxidantes sobre a dentina afetada por cárie na degradação da união com sistemas adesivos / Effectiveness of deproteinizing agents on caries-affected dentin in degradation of bonding systems

Pacheco, Larissa Ferreira, 1983- 24 August 2018 (has links)
Orientador: Regina Maria Puppin Rontani / Tese (doutorado) - Universidade Estadual de Campinas, Faculdade de Odontologia de Piracicaba / Made available in DSpace on 2018-08-24T17:33:00Z (GMT). No. of bitstreams: 1 Pacheco_LarissaFerreira_D.pdf: 2758021 bytes, checksum: 297e755ab6e977e3d0aec5d793c4f9bd (MD5) Previous issue date: 2014 / Resumo: O estudo avaliou a efetividade dos antioxidantes em prevenir a degradação da interface dentina/resina ao longo do tempo. Cento e oito terceiros molares humanos foram submetidos ao modelo biológico de produção de cárie (S. mutans). Eles foram cortados perpendicularmente ao longo eixo do dente, obtendo "flats" de superfície dentinária. Os fatores avaliados são: tratamento ¿ NaOCl à 6%, EDTA, e grupo sem tratamento (Controle); sistemas adesivos - Clearfil SE Bond (SE) e Single Bond 2 (SB); e tempo de armazenamento - 24 horas (h), 12 e 18 meses. Foram construídos blocos de resina (Charisma) sobre a dentina, com altura total de 4 mm. Após 24 h imersos em água deionizada, cada espécime foi seccionado para obtenção de palitos com área média de aproximadamente 2,0 mm2 para a realização do teste de resistência de união (RU). Parte dos palitos obtidos permaneceram submersos em 1 mL de água deionizada por: 12 e 18 meses, sendo então submetidos ao teste de microtração. Os padrões de fratura foram analisados em Microscópio Eletrônico de Varredura (MEV). A nanoinfiltração, ao longo do tempo, foi avaliada por meio de fatias obtidas por secções longitudinais seriadas de outros espécimes. Estas foram imersas em solução traçadora de nitrato de prata amoniacal por 24 h, lavadas em água deionizada e imersas em solução reveladora por 8 h. Todas os espécimes foram observados em MEV para identificar os escores, de acordo com o grau de nanoinfiltração. Os resultados da RU foram analisados quanto à normalidade pelo teste Shapiro-Wilk, sendo verificada a distribuição normal dos dados e em seguida, pelo teste ANOVA Fatorial (axbxc) e teste Tukey post hoc (p<0,05). Os dados da nanoinfiltração e padrão de fratura foram analisados por estatística descritiva. Os resultados mostraram que, com relação ao tempo de armazenamento, o adesivo SB apresentou maiores valores de RU, comparado com o SE e o controle, exceto no tempo de 18 meses. Enquanto o tratamento com EDTA, apresentou maiores valores de RU nos tempo de 24 h e 12 m, e no tempo de 18 m o tratamento com NaOCl apresentou valores maiores, sendo que os dois tratamentos apresentaram valores superiores ao controle. A utilização do SB/EDTA e SE/NaOCl produziu as maiores médias de RU, sendo considerada adesivo-tratamento dependente. Os maiores percentuais do padrão de fratura foram mistos, em todos os grupos, mas, principalmente após 18 meses. Os resultados da nanoinfiltração mostraram que os sistemas adesivos utilizados, idependente do tratamento, apresentaram algum grau de nanoinfiltração porém menores que o apresentado no controle / Abstract: The study evaluated the effectiveness of antioxidants in preventing degradation of dentin/resin interface over time. One hundred and eight third human molars were submitted to a biological model of caries production (S. mutans). It was perpendicular cut to long axis of tooth to obtain a flat dentin surface. The factors evaluated were: treatment - 6% NaOCl, EDTA, and a group without treatment (Controle); adhesive systems - Clearfil SE Bond (SE) and Single Bond 2 (SB); and storage time - 24 hours (h), 12 and 18 months. Were built blocks of resin composite (Charisma) over dentin, with a total height of 4 mm. After 24 h immersed in deionized water, each specimen was sectioned to obtain sticks with an average size of approximately 2 mm2 to realize the bond strength test (µTBS). Parts of sticks obtained remain submerged in 1 ml of deionized water for: 12 and 18 months and then subjected to bond strength test. Fracture patterns were analyzed in Scanning Electron Microscopy (SEM). Nanoleakage evaluation, over time, was measured with slices obtained of serial sections of other specimens. These were embedded in tracer solution of ammoniacal silver nitrate for 24 h, washed in distilled water and immersed in a developing solution for 8 h. All samples were observed under SEM, to identify degree of nanoleakage. Results of µTBS were analyzed for normality by Shapiro-Wilk test being checked normal data distribution, and then, by Factorial ANOVA (axbxc) and Tukey post hoc test (p <0.05). Nanoleakage data and fracture pattern were analyzed using descriptive statistics. The results showed that, with respect to storage time, SB adhesive had higher RU, compared with SE and control, except in time of 18 months. Although EDTA treatment, had higher RU in time of 24 h and 12 m, and at time of 18 m NaOCl treatment showed higher values, and the two treatments were above control values. Use of SB/EDTA and SE/NaOCl produced highest RU average, being considered dependent adhesive-treatment. Largest percentage of fracture pattern was mixed, in all groups, but especially after 18 months. Nanoleakage results showed that adhesive systems used, independent counsel of treatment, showed some degree of nanoleakage but smaller than presented in control / Doutorado / Odontopediatria / Doutora em Odontologia

Page generated in 0.0615 seconds